MOSELECTRO Group of Companies
DOWNLOAD PRESENTATION
Power of Knowledge
MOSELECTRO Group of Companies:
2
Primary Consumers
Electric-power networks
Construction Infrastructure, housing and utilities
Industry
Nuclear industry
Hydropower industry
Oil & Gas industry
Heat-power industry
Transport
projects projects
projects projects
projects projects
projects projects
projects
Over 2,000 completed
projects
Over 1,000 employees
Over 70 years in business MOSELECTROSHIELD
ERA Marin Engineering Center
ENERGY
SPETSENERGO
Engineering Center
ENERGY MOSELECTROSHIELD SPECENERGO
MOSELECTRO
Success Story
3
70 years of progress Moscow plant “Moselectroshield” was founded
First small-sized switchgear development in the USSR
The 1000th worker of the plant was awarded the title of “Shock Worker” (73% of the total staff), including 140 efficiency specialists)
The plant manufactured 70% of packaged switchgear and 40% of busducts in the country
First switchgear manufactured for the Bolshoi Theater
Busbars manufacturing started
Production of switchgear of K-104M series was launched
Manufacture of vacuum-breaker switchgear began
SPETSENERGO Company was established
Russian Busbar Center engineering company was established and became a member of the Group
New engineering solution was developed – a small-sized recloser
Engineering Center Energy LLC joined the Group
Production of 20 kV switchgear of K-131 series commenced
Production of “would-be classic” switchgear of K-125, K-128, K-129 series commenced
Own Solutions – Key Products
6–35 kV switchgear cubicles:
● К-125 “Transformer”
● К-128 “Classic”
● К-129 “Optima”
● К-130 “Guarantor”
● К-131 “Progress”
● К-132 “Innovator”
6/10 kV reclosers with/without energy accounting meters:
● Acting as sectioning switches
● With energy accounting meters
Low-voltage package modules:
● Conventional distribution switchboards
● Protection regulating switchboards for substations (DC boards, auxiliaries boards)
● LV switchgear for unit transformer substations
4
Mobile substations:
● Mobile substations 110/10(6) kV
● Mobile substations 35/10(6) kV
● Modular substations 110/10(6) kV
● Modular substations 35/10(6) kV
TENE TENP
Round enclosure
of TZKR type Rectangular
enclosure of TZPR type
Round enclosure
of TZK type Rectangular
enclosure of TZP type
ShZK-0.4 ShZK-1.2
TENP TZKR ShZK TZP
DC & AC
Busbars
Busbars
Busducts
Up to 1 kV Over 1 kV
Without interphase barriers
With interphase barriers
Phase-screened
Busbar Types
5
Classification:
Busbar Application
1. Generator; 2. Turbine; 3. Phase-screened busbar of IPB type (Isolated
phase bus duct, natural cooling); 4. Auxiliary phase-screened busbar of IPB type; 5. Auxiliary transformer; 6. Auxiliary busduct of SPB (Segregated Phase
Bus Duct) round enclosure or NSPB type (Non-Segregated Phase Bus Duct, round enclosure);
7. Power step-up transformer; 8. Forced cooling system (for phase-screened busbars of IPBFC type (Isolated phase bus duct
forced cooling) only); 9. Excitation transformer with a phase-screened busbar of IPB type (Isolated phase bus duct,
natural cooling); and 10.Generator neutral grounding. 6
Busbars
7
Advantages of Air-insulated Busbars
1. Simple maintenance, low operation and repair costs;
2. Long service lifetime – up to 50 years;
3. Corrosion resistance;
4. High power transfer with a current load of up to 26 kA at 35 kV with natural cooling and up to 37 kA with voltage of up to 35 kV with forced cooling;
5. High reliability. All-welded (leakproof) design;
6. Considerable reduction of phase-to-phase and three-phase short circuits for interphase barrier busbars and phase-screened busbars;
7. High electrodynamic stability;
8. Near-zero external magnetic field for phase-screened busbars;
9. Self-supporting capacity of up to 6 meters. Use of simple support structures; and
10. Full compliance with strict GOST (IEC) standards.
Busbar Specifications
8
Basic Characteristics:
• Voltage 0.4-35 kV; • Rated current 1,600 to 37,000 A; • AC frequency 50/60 Hz; • Climatic version UKhL, Т and placement category 1,3 per GOST 15150 (IEC
60721-2-1); • Atmosphere type II per GOST 15150 (IEC 60721-2-1); • Seismic category II per NP 031-01 (safety class 3Н per OPB-88/97) for intensity
9 on MSK-64 scale and at elevation of up to +10 m and intensity 8 at elevation of up to +25 m;
• Operation condition group М5 per GOST 17516.1 (IEC 60721-3); and • Protection degree IP 54(55) per GOST 14254 (IEC 60529).
Busbar Design
9
Design Features
• Special sections with expansion joints provide necessary thermal expansion to the busbar and the enclosure during operation;
• Flexible joints at points of connection to power equipment prevent vibration transmission and propagation;
• Design of support insulator attachment enables free access for inspection, cleaning or replacement; and
• Use of aluminum as a structural material ensures low weight of sections, which facilitates rigging operations and enables safe and quick installation.
Busbar Design
10
Design Features • The design incorporates support insulators with highly
hydrophobic organic-silicon enclosures;
• Bolt joints only at points of connection to equipment. The enclosure design at connection points provides free access for inspection and checking bolt tightening;
• Contact surfaces of bolt joints have protective coating to reduce transient resistance; and
• Ease of aluminum workability enables compensation of any construction design deviations during assembly by cutting or expanding busbar and enclosure elements.
Types of Busbar Sections
11
A busbar consists of sections. The product is supplied for installation fully shop-assembled with sections up to 8 meters long, which results in low installation costs.
The busbar route is divided in separate sections.
Corner section Z-shaped section (in different planes)
Straight section
Section with integrated equipment
Equipment connection section
IPB Busbars
12
Technical Parameters of IPB (Isolated phase bus duct, natural cooling)
Rated voltage,
kV Rated current,
A Dynamics
current, kA
Enclosure overall
dimensions, mm
Phase-to-phase clearance, mm
TZKEP 6 2,000-4,000 128-170 361 450
TENE
10 3,150-6,300 128-250 408 500
20 1,600-12,500 300-560 550-890 1,000-1,300
24 2,000-24,000 560-750 678-1362 1,000-1,800
35 5,000 560 800 1,000
IPB busbars are designed for electrical connection of turbine generators with power step-up transformers, auxiliary transformers, converter transformers and generator thyristor excitation transformers.
NSPB and SPB Busbars
13
Technical Parameters
Rated voltage, kV Rated current, A Dynamics current,
kA Enclosure overall dimensions, mm
TZK
6 1,600-3,150 81-128 550-640
10 1,600-4,000 81-170 623-706
20 2,000-3,150 128 890
TZKR
6 1,600-2,000 81 623-640
10 1,600-4,000 81-170 700-890
20 3,150-6,300 128 1,090-1,240
Round busbars with non-segregated and segregated phases
NSPB, SPB busbars are designed for electrical connections in auxiliary circuits of power stations, transformers with switchgear cabinets, as well as turbine generators with power step-up transformers.
NSPB and SPB Busbars
14
Technical Parameters of NSPB and SPB (Non-Segregated and Segregated Phase Bus Duct, rectangular enclosure )
NSPB and SPB busbars are designed for electrical connections in auxiliary circuits of power stations, transformers with switchgear cabinets, as well as turbine generators with power step-up transformers.
Rated voltage, kV Rated current, A Dynamics current,
kA Enclosure overall dimensions, mm
TZP
6 1,600-3,150 81-128 800x320
10 1,600-4,000 81-170
920x380
20 1180x500
TZPR
6 1,600-3,150 81 960x320
10 1,600-4,000 81-170
1140x380
20 1500x500
Reliability Enhancement Systems
15
Pressurization system creates overpressure inside the busbar by continuous dehydrated air charging.
Advantages: • Ensures relative air humidity less than 30-
40%; • Maintains busbar pressure above
atmospheric pressure by 600-1,000 Pa; • Increases the busbar protection degree up
to IP64 (IP65); and • Possible displaying of air humidity and
pressure values on the control unit panel.
16
UKOI-M system solves the problem of resistance measuring of each busbar support insulator with simultaneous data display for all insulators in the form convenient to the operator.
Advantages: • On-line measuring of insulator resistance within
the range of 1 to 3,600 MΩ at operating voltage;
• Original scheme of connection to the power unit, preventing any modifications to the grounding system for busbars and switching devices and tampering with protection and other systems; and
• Data can be transferred to the automation system.
Reliability Enhancement Systems
Insulators
Insulators
Insulators
Insulators
Receiving/ transmitting module
Control module
Measuring
module (1)
Measuring module (2)
Measuring
module (3)
Measuring module
(N)
Busbar Testing
17
Type tests for: • Environmental resistance per GOST 15150 (IEC 60721-2-1); • Heating under continuous operation per GOST 8024 (IEC 62271-1); • Insulation strength per GOST 1516.3 (IEC 62271-1); • Short-time withstand and peak currents to manufacturer’s specifications (IEC
62271-1); • Protection degree per GOST 14254 (IEC 60529); and • Mechanical environmental stability and seismic resistance per GOST 17516.1,
ОПБ-88/97 (IEC 60721-3, IEC 60980).
Factory acceptance tests of finished products: • External examination; • Examination for compliance with design documentation; • Insulation strength test with one-minute voltage per GOST 1516.3 (IEC 62271-
1); • Completeness check; and • Marking, preservation and packaging checks.
Integrated solutions: ● Indoor integrated transformer
substations ● Modular integrated transformer
substations 10/0.4 kV in a concrete building for 10(20)/0.4 kV.
● Sandwich-type integrated transformer substations 10(20,35)/0.4 kV.
● Outdoor switchgear 110/10(35) kV. ● Indoor switchgear for GIS 110/10(35)
kV ● Automatic voltage control station
(AVCS).
Design:
● Research and development
● Design of facilities up to 220 kV of any complexity; project management
● Process automation, introduction of energy-saving technologies
Equipment operation services:
● Installation, installation supervision
● Set-up, commissioning
● Warranty and service maintenance
18
Services
● All products of the company’s plant are certified for compliance with Russian and international standards (GOST R and IEC) and safety requirements;
● Certification by OJSC “Russian Networks” (OJSC “FSK”);
● Certification by OJSC “NK ROSNEFT”, OJSC “Gazprom”, OJSC “AK Transneft”;
● License of GosAtomNadzor of Russia for design and manufacture of nuclear power station equipment;
● International Quality Certificate TUV ISO 9001: 2008 in the area of development and design for power stations, substations and industrial enterprises; and
● Other certificates, licenses and qualifications.
Licenses and Certificates
19
Sales Geography
20
Finland Ukraine
Belorussia Croatia
Germany
Russia Over 1,000 projects
China
Bangladesh
Kazakhstan
Uzbekistan Tajikistan
Iran
Bulgaria
Argentina
Ecuador
Electric-power industry
Shipbuilding Infrastructure and industry
Defense industry complex
Nuclear power industry
Hydropower industry
Oil & Gas Heat-power industry
www.moselectro.ru
DOWNLOAD CONTACTS
Power of Knowledge
Recommended