● High-resolution and clearly display (10.4" TFT LCD)
● Built-in printer for copy of the echogram history
● High accuracy and high reliability
● Depth data for last 24 hours in memory to play back
the past sounding information
● Meets IMO standards MSC.74 (69) Annex 4
● High-resolution and clearly display (10.4" TFT LCD)
● Built-in printer for copy of the echogram history
● High accuracy and high reliability
● Depth data for last 24 hours in memory to play back
the past sounding information
● Meets IMO standards MSC.74 (69) Annex 4
NAVIGATIONAL ECHO SOUNDER
JFE680_ocf_1022.qxd 12.10.22 5:00 PM ページ 1
187.2
CABLE INLET
CABLE INLET
316.5
170(MIN)
CABLE INLET
CABLE INLET
295.5
334
334252±1
218±1
295.5
4-φ12 OR M10MOUNTING HOLES
351±0.58.5±0.5
175.5±0.5 175.5±0.5
334±0.5
376
8.5±0.5
10±0.5255.5±0.5
316.5
336.5
361.5
30.5±0.5
30.5±0.5
10±0.5
6-φ7 OR M6
MOUNTING HOLES
Wall-Mounting Flush-Mounting
*Secondary units(transducer, matching box, cable)are optional.
(Unit :mm)
CABLE INLET
CABLE INLET
■SPECIFICATIONS
■COMPONENT
Display
Frequency
Echo color
Digital depth
Range
Depth accuracy
Minimum sounding depth
Draft adjust
TX pulse repetition rate
Presentation mode
Time range of echo display
Auto function
Alarm function
Preview function
Transducer
Power supply
Power consumption
Waterproofing
10.4" Color TFT LCD(640x480 pixels)
200kHz / 50kHz
8 colors or 8 level monochrome
4 digit (0.1m)
10, 20, 50, 100, 200, 500, 800m
±2.5%
200kHz : 1.0m, 50kHz : 2m
50m in 0.1m steps
171PRR(10, 20, 50m)
86PRR (100, 200m)
43PRR (500, 800m)
Standard, History, Docking
5, 10, 20, 30min
Gain, Range
Depth, Power fail, System error
24hour
200kHz : UT-200ND
50kHz : UT-50MD
100-115/200-230VAC±15%, 50Hz/60Hz±5%
24VDC(only use for power fail monitoring)
less than 50W
IPX2 drip proof
Display unit
Matching box (primary)
Transducer mounting (primary)
Option
JFE-680
AW-154F
NKF-341
AW-154F
AW-154F-50
NKF-341
NKF-345
7ZPJD0384
BRBX05351
BRBX05355
BRBX05354
BRBX05340
200kHz
200kHz (with cable 20m)
200kHz
50kHz
200kHz (with cable 20m)
50kHz (with cable 20m)
Color : MUNSELL N4
Color : MUNSELL 7.5BG7/2
Color : MUNSELL 2.5G7/2
1
1
1
1
1
1
1
1
1
1
1
1
Name Type No. RemarksQty
■OUTLINE DRAWING
JFE-680
■CONFIGRATION
Matching box (secondary)
Transducer mounting (secondary)
Printer paper
Flush mounting kit
Table mounting kit
MASS : 8kg
200 or 50kHz for AW-154F or AW-154F-50
Primary 0.6/1kV DPYCS-2.5(Shipyard)
Secondary 0.6/1kV DPYCS-2.5(Shipyard)
JRC 20m φ12.9
JRC 20m φ12.9
Transducer Transducer
200 or 50kHz for NKF-341 or NKF-345
250V TTYCS-1(Shipyard)
250V TTYCS-1(Shipyard)
250V TTYCS-1(Shipyard)
250V TTYCS-1(Shipyard)
250V TTYCS-1(Shipyard)
250V TTYCS-1(Shipyard)
250V TTYCS-1(Shipyard)
250V TTYCS-1(Shipyard)
250V TTYCS-1(Shipyard)
250V TTYCS-1(Shipyard)
0.6/1kV DPYC-1.5(Shipyard)
0.6/1kV DPYC-1.5(Shipyard)
IEC61162-1 External navigation equipment
IEC61162-1 ALR sentence input
IEC61162-1 Water depth data output
IEC61162-1 ALR data output
Water depth alarm signal output
Water depth alarm buzzer stop signal input
System alarm signal output
System alarm buzzer stop signal input
Power supply alarm signal output
Power supply alarm buzzer stop signal input
24V DC power supply (To power fail alarm control)
100~230V AC power supply (To main unit)
200 or 50kHz for AW-154F or AW-154F-50
200 or 50kHz for NKF-341 or NKF-345
For further information, contact:
Since 1915
Main Office:
Overseas Branches : Seattle, Amsterdam, Athens, Manila Liaison Offices : Taipei, Jakarta, Singapore, Hanoi,
Hamburg, New York
28EM ISO9001,ISO14001 Certified
●Specifications may be subject to change without notice.
URL eng
Printed in Japan2007.1 CAT.No.Y10-139(No.490-6-3)D2012.10
Fujisawa bldg. 30-16, Ogikubo 4-chomeSuginami-ku, Tokyo 167-8540, JapanTelephone: +81-3-6832-1816Facsimile: +81-3-6832-1845
JFE680_ocf_1022.qxd 12.10.22 5:00 PM ページ 2