View
383
Download
20
Category
Preview:
Citation preview
7/25/2019 Operador Pax elevador otis
1/18
OTISOPERADOR PUERTA PAX
Ref.: CC53
Pgina: 1/18
F. edicin: ABRIL. 2003
F. Revisin:
MANUAL TCNICO DECONSULTA
OPERADOR PAX(SIEMENS AT120)
JS/llr
ndice
7/25/2019 Operador Pax elevador otis
2/18
OTISOPERADOR PUERTA PAX
Ref.: CC53
Pgina: 2/18
F. edicin: ABRIL. 2003
F. Revisin:
MANUAL TCNICO DECONSULTA
1 INTRODUCCIN ................................................................................32 COLGADOR DE PUERTAS Y CAJA DE CONTROL ........................4
3 INFORMACIN TCNICA..................................................................54 ESTRUCTURA DEL MEN DEL TIL DE PRUEBAS ......................85 PUESTA EN MARCHA INICIAL.........................................................9
6 PROCEDIMIENTO DE AJUSTE.......................................................107 CODIGOS DE ERROR .....................................................................16
8 MANTENIMIENTO............................................................................179 NUMEROS DE PIEZA ......................................................................1810 SUSTITUCION DE LA CINTA DE TRACCIN
(EN PREPARACION) .......................................................................18
7/25/2019 Operador Pax elevador otis
3/18
OTISOPERADOR PUERTA PAX
Ref.: CC53
Pgina: 3/18
F. edicin: ABRIL. 2003
F. Revisin:
MANUAL TCNICO DECONSULTA
1- INTRODUCCINEl operador PAX es un sistema de control sin mantenimiento que consiste en un motorDC de corriente continua con reductor y un dispositivo de control de velocidad. La trans-misin de movimiento a las puertas se realiza a travs de una cinta dentada, guiada poruna polea de desvo. Puede manejar tanto puertas de apertura telescpica como centra-les.
No utiliza finales de recorrido para su funcionamiento. El ancho de la apertura y las posi-ciones de puerta abierta y cerrada se calculan de modo automtico por medio de un viajede aprendizaje.
ATENCIN
Todos los trabajos en este equipo y en su proximidad deben ser realizados exclusivamentepor personal cualificado. Dicho personal debe estar completamente informado acerca delos riesgos y procedimientos de acuerdo a estas instrucciones.
Para asegurar el correcto y seguro funcionamiento del sistema, es necesario asegurar suadecuado transporte, almacenamiento y montaje, as como el posterior mantenimiento delconjunto.
7/25/2019 Operador Pax elevador otis
4/18
OTISOPERADOR PUERTA PAX
Ref.: CC53
Pgina: 4/18
F. edicin: ABRIL. 2003
F. Revisin:
MANUAL TCNICO DECONSULTA
2- COLGADOR DE PUERTAS Y CAJA DE CONTROL
Conexin con la maniobra
Transformador
Pulsador de Aprendizaje
Util de Pruebas
Al Motor yEncoder
TRANSFORMADO CAJA DE CONTROL
MOTOR
7/25/2019 Operador Pax elevador otis
5/18
OTISOPERADOR PUERTA PAX
Ref.: CC53
Pgina: 5/18
F. edicin: ABRIL. 2003
F. Revisin:
MANUAL TCNICO DECONSULTA
3- INFORMACIN TCNICA
Motor-reductor cc
Tensin Max. 24 V cc
Velocidadmxima
0,5 m/s
Proteccin IP20
Transmisin 15:1
Encoderincremental
Sharp
(100 incrementos por revolucin)
Corrientenominal
1.8 A
Transformador (peso de las puertas 120 kg)Tensinalimentacin
230V ca/ 400V ca (50 60 Hz)
Toleranciaalimentacin
15%
0 + 50 CTemperatura defuncionamiento
IP 54Proteccin
Tensinnominal desalida
30,5 V cc
Corrientemxima ensecundario
3,6 A
Termopar
Filtro principal Incluido en montaje
No incluido
7/25/2019 Operador Pax elevador otis
6/18
OTISOPERADOR PUERTA PAX
Ref.: CC53
Pgina: 6/18
F. edicin: ABRIL. 2003
F. Revisin:
MANUAL TCNICO DECONSULTA
Caja de controlTensinalimentacin
30,5 V cc
Fusible 5 X 20 T2.0 A
IP 20 (desde arriba y frontal IP43)Proteccin
Entradas 24 V 5%
Apertura 700 mm a 900 mm
-20 +80C
Temperatura dealmacenamiento
0 +50C
Sin exposicin solar directaTemperatura de
funcionamiento
Humedadambiental
Sin condensacin
HomologacionesCertificacinEMC
EN 12015 y EN 12016
TV (MOT) Ensayos realizados
CE Certificado
7/25/2019 Operador Pax elevador otis
7/18
OTISOPERADOR PUERTA PAX
Ref.: CC53
Pgina: 7/18
F. edicin: ABRIL. 2003
F. Revisin:
MANUAL TCNICO DECONSULTA
FUNCIN Valor por defecto Atxx RANGO DE AJUSTESword route ""OPEN""" 5 cm 00.10m
Creeping-route ""OPEN"" 5 cm 00.10m
Sword route ""CLOSE""" 5 cm 00.10m
Creeping-route ""CLOSE"" 5 cm 00.10m
Acceleration ramp ""OPEN"" 50 cm/s2
3080cm/s
2
Brake ramp ""OPEN"" 50 cm/s2 3080cm/s2
Acceleration ramp ""CLOSE"" 50 cm/s2 3080cm/s2
Brake ramp ""CLOSE"" 50 cm/s2 3080cm/s2
Reversing-ramp "OPEN-CLOSE" 50 cm/s2 3080cm/s2
Reversing-ramp "CLOSE-OPEN" 50 cm/s2 3080cm/s2
Min. opening speed (Sword Route) 6cm/s 39cm/s
Min. opening speed 6cm/s 39cm/s
Min. closing speed (Sword Route) 6cm/s 39cm/s
Min. closing speed 6cm/s 39cm/s
Max. opening speed 40cm/s 1050cm/s
Max. closing speed 25cm/s 1050cm/s
Nudging speed 15cm/s 525cm/s
Opening force Valor mximo del motor 80Nvalor mximo delmotor
Closing force 115N 80150N
Closing force (Sword Route) 115N 80150N
Continuous momentum ""CLOSE"" Intensidad 0,5A Intensidad 01,0A
Continuous momentum ""OPEN"" Intensidad 0,5A Intensidad 01,0A
Pressure momentum ""CLOSE"" Intensidad 2,0A Intensidad 02,0A
Nudging force 115N 80150N
Recorrido en lenta inicio apertura
Rampa de aceleracin en apertura
Recorrido en lenta fin apertura
Recorrido en lenta inicio cierre
Recorrido en lenta fin cierre
Rampa de deceleracin en apertura
Rampa de aceleracin en cierre
Rampa de deceleracin en cierre
Rampa en inversin abrir-cerrar
Rampa en inversin cerrar-abrir
Velocidad mnima inicio de apertura
Velocidad mnima de apertura
Velocidad mnima inicio de cierre
Velocidad mnima de cierre
Velocidad mxima de apertura
Velocidad mxima de cierre
Velocidad de cierre forzoso
Par de apertura
Par de cierre
Par al inicio del cierre
Corriente nominal en cierre
Corriente nominal en apertura
Corriente bajo presin en cierre
Par en cierre forzoso
7/25/2019 Operador Pax elevador otis
8/18
OTISOPERADOR PUERTA PAX
Ref.: CC53
Pgina: 8/18
F. edicin: ABRIL. 2003
F. Revisin:
MANUAL TCNICO DECONSULTA
4- ESTRUCTURA DEL MEN DEL TIL DE PRUEBAS
NOTA: el rea sombreada sonpantallas ocultas del Util dePruebas. Para acceder a ellas,debe pulsarse la secuenciaAZUL-7 estando en la pantallainicial.
ATXX
Puls
e3
7/25/2019 Operador Pax elevador otis
9/18
OTISOPERADOR PUERTA PAX
Ref.: CC53
Pgina: 9/18
F. edicin: ABRIL. 2003
F. Revisin:
MANUAL TCNICO DECONSULTA
5- PUESTA EN MARCHA INICIAL
La puesta en marcha debe realizarse segn detalla el captulo 6 de este manual.
El contol del operador es capaz de encontrar automticamente las posiciones finales delas puertas y el ancho de la apertura por medio del viaje de aprendizaje.
Hay dos posibilidades para iniciar este viaje, bien a travs del pulsador del propio equipo(ver a continuacin 3.a), bien a travs del Util de Pruebas (ver 3.b).
Si va a utilizarse el Util de Pruebas OTIS para realizar el aprendizaje, debe conectarse ala placa de control ST-302 antes de alimentar sta. Tras conectar alimentacin, se realizauna rutina de comprobacin durante aproximadamente 20 segundos. En este tiempo elcontrol del operador no acepta ningn comando.
Para realizar el viaje de aprendizaje deben seguirse los siguientes pasos :
1. Coloque manualmente las puertas en posicin de abiertas.2. El control necesita encontrar el comando TCI-STOP en la placa interface (ST301).3. a)Presione el pulsador (A) durante ms de tres segundos.
b) El Util de Pruebas OTIS debe conectarse a la placa de control (ST302). El proce-dimiento se muestra a continuacin, y debe seguirse paso a paso.
(A)
7/25/2019 Operador Pax elevador otis
10/18
OTISOPERADOR PUERTA PAX
Ref.: CC53
Pgina: 10/18
F. edicin: ABRIL. 2003
F. Revisin:
MANUAL TCNICO DECONSULTA
6- PROCEDIMIENTO DE AJUSTEAntes de conectar la alimentacin
Compruebe las siguientes conexiones en la placa de control :
Motor y encoder conectados en ST306.I/O (entradas y salidas) y 24 Vdc en P5.Alimentacin desde el transformador al conector ST1.Alimentacin desde el transformador a la caja de conexiones.
Despus de ajustar mecnicamente las puertas de cabina con las de piso (cotas de aco-plamiento entre ambas y holguras de cerraduras) :
Site la cabina a nivel y pngala en modo INSPECCION.Desde el techo de cabina, abra a mano completamente las puertas.Conecte la alimentacin al operador, y espere hasta que escuche un clic en la cajade control (aproximadamente 20 segundos).Presione el pulsador de aprendizaje del control durante al menos 3 segundos.
Las puertas iniciarn el viaje de aprendizaje, durante el cual realizar 1 o 2 ciclos de aper-tura y cierre.
Conecte el Util de Pruebas en la caja de control para abrir y cerrar las puertas.
Si no funciona correctamente, deje conectado el Util de Pruebas al operador y corte ali-mentacin.
Welcome to ATxx
ATxx=3
Monitor =1 Test = 2
Tools = 4
Single Run = 1
Cont Run = 2
Open = 1 Close = 2Stop = 3 Revels = 4
Pulse 1 para abrir
Pulse 2 para cerrar
Pulse Module
Pulse 3
Pulse 4
Pulse 1
Please switch
to TCI!
POSIBLE PANTALLA
7/25/2019 Operador Pax elevador otis
11/18
OTISOPERADOR PUERTA PAX
Ref.: CC53
Pgina: 11/18
F. edicin: ABRIL. 2003
F. Revisin:
MANUAL TCNICO DECONSULTA
Welcome to AtxxAtxx = 3
Monitor = 1 Test = 2Tools = 4
Monitor = 1 Test = 2Setup = 3 Tools = 4
Press 3
Press SHIFT 7
SELF TEST INPROGRESS
SELF TESTOK-MECS-MODE
SELF TESTOK-MP2/3-MODE
Start ENTER
Press 1
Welcome to AtxxAtxx = 3
Monitor = 1 Test = 2Tools = 4
Monitor = 1 Test = 2Setup = 3 Tools = 4
Install = 1Field = 3 ENG = 4
SELF TEST INPROGRESS
SELF TESTOK-MECS-MODE
SELF TESTOK-MP2/3-MODE
Config = 1SetDef = 9
Start learn runPress ENTER
Press Module
Install = 1Field = 3 ENG = 4
Press 3
Welcome to AtxxAtxx = 3
Monitor = 1 Test = 2Tools = 4
Monitor = 1 Test = 2Setup = 3 Tools = 4
Press 3
Press SHIFT 7
SELF TEST INPROGRESS
SELF TESTOK-MECS-MODE
SELF TESTOK-MP2/3-MODE
Start ENTER
Press 1
Welcome to AtxxAtxx = 3
Monitor = 1 Test = 2Tools = 4
Monitor = 1 Test = 2Setup = 3 Tools = 4
Install = 1Field = 3 ENG = 4
SELF TEST INPROGRESS
SELF TESTOK-MECS-MODE
SELF TESTOK-MP2/3-MODE
Config = 1SetDef = 9
Start learn runPress ENTER
Press Module
Install = 1Field = 3 ENG = 4
Conectealimentacin
Welcome to AtxxAtxx = 3
Monitor = 1 Test = 2Tools = 4
Monitor = 1 Test = 2Setup = 3 Tools = 4
Pulse 3
Pulse AZUL-7
Pulse 1
SELF TEST INPROGRESS
SELF TESTOK-MECS-MODE
SELF TESTOK-MP2/3-MODE
Start ENTER
Pulse 1
Pulse Azul +ENTER
AHORADesde el techo de cabina, abra a mano
completamente las puertas.
Welcome to ATxxATxx = 3
Monitor = 1 Test = 2Tools = 4
Monitor = 1 Test = 2Setup = 3 Tools = 4
Install = 1Field = 3 ENG = 4
Pulse 3
SELF TEST INPROGRESS
SELF TESTOK-MECS-MODE
SELF TESTOK-MP2/3-MODE
Config = 1SetDef = 9
start learn runpress
Pulse Module
Install = 1Field = 3 ENG = 4
Pulse 3
Desconecte y conecte de nuevo el Util dePruebas e inicie de nuevo la secuencia
Si an no se realiz el aprendizaje mediante elpulsador de la caja de control, o si ste no concluycorrectamente, realice las siguientes operaciones.
Pulse 1
Si ya se realiz el aprendizaje,acceda directamente a la
modificacin de parmetros.Pulse 3
Start learn runPress ENTERStart learn runPress ENTERMove door [ ]Start:
7/25/2019 Operador Pax elevador otis
12/18
OTISOPERADOR PUERTA PAX
Ref.: CC53
Pgina: 12/18
F. edicin: ABRIL. 2003
F. Revisin:
MANUAL TCNICO DECONSULTA
Press 3
Init Run = 1Door Para Run = 2
Door is runningStop Door run = 3
Press 1
Para run finishPress Funtkey
Para run failedRun again : SET
Install = 1Field =3 ENG = 4
Aparecen los parmetros de ajuste. Compruebe queson los de la tabla siguiente:
Press 3
Init Run = 1Door Para Run = 2
Door is runningStop Door run = 3
Para run finishPress Funtkey
Para run failedRun again : SET
Install = 1Field =3 ENG = 4
Press 3
Pulse SET
Pulse 1
Init Run = 1Door Para Run = 2
Door is runningStop Door run = 3
Pulse 1
Inicialmente, las puertas abrirn y cerrarn de 10 en 10cm en velocidad lenta.
Posteriormente, las puertas cerrarn en velocidad lenta.
Para run finishPress Funtkey
Para run failedRun again : SET
Las puertas estn cerradas.
Si se ha producido un error durante elaprendizaje, abra de nuevo a mano
completamente las puertas
Realice de nuevo el viaje de aprendizaje.
Despus del aprendizaje, si el funcionamiento no es eladecuado, es posible modificar los parmetros.
Install = 1Field =3 ENG = 4
door is runningStop Door run = 3
Para Run finishpress
Para run failedRun again : SET
Install = 1Field =3 ENG = 4
Aprendizaje:1- con los parmetros
por defecto2- con parmetros
personalizados
Pulsar
Tecla
7/25/2019 Operador Pax elevador otis
13/18
OTISOPERADOR PUERTA PAX
Ref.: CC53
Pgina: 13/18
F. edicin: ABRIL. 2003
F. Revisin:
MANUAL TCNICO DECONSULTA
PARAMETROS (%)TLD700
TLD750
TLD800
TLD850
TLD900
CLD800
CLD900
Start Opn Dist 50 50 50 50 50 50 50Open Crp Dist 10 10 10 10 10 20 20
Close Crp Dist 70 70 70 70 70 50 50Start Cls Dist 20 20 20 20 20 20 20Accel Open 40 40 40 40 40 40 40Decel Open 40 40 40 40 40 40 40Accel Close 40 40 40 40 40 40 40Decel close 40 40 40 40 40 40 40Reversal Open 40 40 40 40 40 40 40Reversal Close 40 40 40 40 40 40 40Start Open Speed 69 69 69 69 69 69 69Open Crp Speed 46 46 46 46 46 46 46Close Crp speed 20 20 20 20 20 20 20Start Close Speed 30 30 30 30 30 30 30
Max Open Speed 62 62 62 62 62 54 54Max Close Speed 38 38 38 38 38 41 41Nudging Speed 47 47 47 47 47 47 47Open Torque 100 100 100 100 100 100 100Close Torque 50 50 50 50 50 50 50Close Creep Torque 50 50 50 50 50 50 50Close Idle Torque 50 50 50 50 50 50 50Open ldle Torque 50 50 50 50 50 50 50Close Push Torque 100 100 100 100 100 100 100Nudging Torque 50 50 50 50 50 50 50Stop Torque 255 255 255 255 255 255 255
TLD = puertas de apertura telescpicaCLD = puertas de apertura central
7/25/2019 Operador Pax elevador otis
14/18
OTISOPERADOR PUERTA PAX
Ref.: CC53
Pgina: 14/18
F. edicin: ABRIL. 2003
F. Revisin:
MANUAL TCNICO DECONSULTA
Los parmetros principales son los que aparecen sombreados en la tablaanterior.
Para modificar los parmetros, las puertas deben estar cerradas.Para comprobar el funcionamiento de las puertas despus de un cambio de
parmetros, siga la siguiente secuencia con el Util de Pruebas:
Install = 1Field = 3 ENG = 4
Monitor = 1 Test = 2Setup = 3 Tools = 4
Single Run = 1
Cont Run = 2
Open = 1 Close = 2Stop = 3 Revels = 4
Pulse SET
Pulse 4
Pulse 1
Despus de comprobar la operacin de puertas, acceda al men de ajuste de
parmetros pulsando Set, Function y 3.
Pulse 1 para abrir
Pulse 2 para cerrar
7/25/2019 Operador Pax elevador otis
15/18
OTISOPERADOR PUERTA PAX
Ref.: CC53
Pgina: 15/18
F. edicin: ABRIL. 2003
F. Revisin:
MANUAL TCNICO DECONSULTA
Curvas de funcionamiento y parmetros relacionados
open position
S
Close CrpDist
Accel close
S
Open CrpDist
Decel Open
Accel Open
Max OpnSpeed
Start OpnSpeed
close position open position
Opening direction
Start OpnDist
Open CrpS eed
V
Max ClsSpeed
Start Cls
Speed
close positionStart ClsDist
Closing direction
Decel closeClose CrpSpeed
V
7/25/2019 Operador Pax elevador otis
16/18
OTISOPERADOR PUERTA PAX
Ref.: CC53
Pgina: 16/18
F. edicin: ABRIL. 2003
F. Revisin:
MANUAL TCNICO DECONSULTA
7- CODIGOS DE ERROR
Restricciones:
Slo se almacenan los ltimos cuatro errores. Los anteriores se van borrando a medi-da que se almacenan los nuevos.
No hay contador ni informacin de tiempo para determinar con qu frecuencia y enqu momento ocurri un error.
El listado de errores se borra al cortar corriente.
Pantallas del Util de Pruebas:
Cuando se accede al men de errores, aparecen 2 opciones. Con la primera de ellas( Actual ), se muestra el listado de los cuatro ltimos errores detectados. Con la segun-da ( Delete ) se borra el listado.
Pulse 1
La primera informacin el el men Actual muestra las operaciones de puertas realiza-das y el tiempo transcurrido desde la ltima vez que se aliment el operador.
El formato de la informacin de tiempo esdas :horas :minutos :segundos.
Pulse para acceder a la descripcin de los errores
Avance en la lista pulsando GO ON
El operador PAX slo almacena los ltimos cuatro errores (vea el apartado restricciones ).
Actual = 1Delete = 9
Runs = xxxxxxxxxTime =xxxxxxxxxx
Error/Event description 1Error/Event description 2 >
Error/Event description 3Error/Event description 4 >
7/25/2019 Operador Pax elevador otis
17/18
OTISOPERADOR PUERTA PAX
Ref.: CC53
Pgina: 17/18
F. edicin: ABRIL. 2003
F. Revisin:
MANUAL TCNICO DECONSULTA
8- MANTENIMIENTO
Pantalla del Util de Pruebas:
Tiempo total en funcionamiento. Formato: horas :minutos :segundos das aos
Pulsar GOON para avanzar pantallas:
xxxxxx = total de operaciones realizadas.
Days alive :
hh:mm:ss ddd yy >
Total Cycles :xxxxxxx >
ErrorPantalla Util(16 caracteres)
Detalle
0x00 no errors
0x01 uP system error Fallo RAM,EPROM o CPU
0x02 EEprom defect
0x03 AD convers. fail Fallo conversor analg-digital
0x04 wrong parameter Error en clculo parmetros.
0x05 SIO defect Fallo interface serie
0x06 motor blocked Proteccin de motor bloqueado (PP)0x07 encoder defect
0x08 no errors Puertas cerradas. No hay error.
0x09 no errors Fotoclula activada. Sin error.
0x0A overcurrent Sobrecorriente en motor.
0x0B Init run stopped Inicializacin interrumpida.
0x0C blocked open Puerta bloqueada en apertura (3 veces)
0x0D init run Viaje de inicializacin.
0x0E overvoltage Voltaje motor > 42 volts
0x0F undervoltage Voltaje motor < 10 volts
0x10 wrong current Fallo del sensor de corriente.
0x11 motor overstress Relacin tensin on / off > 50%0x12 wait for initrun Esperando viaje inicializacin.
No hay errores detectados
Fallo de la memoria EEPROM
Fallo del encoder
7/25/2019 Operador Pax elevador otis
18/18
OTISOPERADOR PUERTA PAX
Ref.: CC53
Pgina: 18/18
F. edicin: ABRIL. 2003
F. Revisin:
MANUAL TCNICO DECONSULTA
9- NUMEROS DE PIEZA
Pantalla del Util de Pruebas:
Versin: nmero de piezaDate: fecha de fabricacin
10- SUSTITUCIN DE LA CINTA DE TRACCIN (EN PREPARACIN)
Version Nr xxxxxxxxxxxxDate xxxxxxxxxx