Variable Speed Drive Compressors - CIIGBC Dave Atlas Copco Compressor Sales-Pune 4th September 2010...

Preview:

Citation preview

Anil Dave

Atlas Copco Compressor Sales-Pune

4th September 2010

Compressed Air Energy Conservation, CII Chennai

Variable Speed Drive Compressors

2 4th Sept 2010

AGENDA

What is VSD.

Why is VSD required.

How VSD works.

Benefits of VSD.

Who & When should opt for VSD compressor.

References

Leadership in Energy and Environmental Design (LEED Certification)

3 4th Sept 2010

VSD – ADVANCED TECHNOLGY

TO REDUCE ENERGY CONSUMPTION

4 4th Sept 2010

What is VSD Compressor

VSD or Variable Speed Drive Compressor is a compressor – which varies the capacity (FAD) based on the Air Demand pattern and – consumes power proportional to Air Demand.– thereby saving energy which would have gone waste in case of Fixed speed

compressor.

5 4th Sept 2010

Why VSD is required?

6 4th Sept 2010

Why VSD is required?

Because, not all applications demand continuous full load.

Because a plant may have intermittent Compressed Air Applications.

Because Air demand pattern vary within a Day (e.g.Lunch time, Air demand is negligible)

Because plants have 1 or 2 days off, so negligible air demand.

Because different production shifts do not consume same amount of Air (e.g. night shift production may need less Compressed Air then day shift.)

Finally, because we pay for Power.

7 4th Sept 2010

Cost Allocation

Investment cost consists of:– Purchase price– Installation cost

Investment cost depends on:– Proper selection of compressor

Capacity (FAD)PressureOperating Pattern

Energy cost is determined by:– Annual operating time– Load/unload utlisation– Unit energy cost.

8 4th Sept 2010

Energy savings Facts & Figures

70% of industrial electrical consumption is for electric motors

compressed air consumes 10 to 20 % of industrial electrical capacity

this accounts for over 55 million tons of CO2 emissions per year

Electricity comprises more the 70% of the total life cycle cost of acompressor

70% of industrial electrical consumption is for electric motors

compressed air consumes 10 to 20 % of industrial electrical capacity

this accounts for over 55 million tons of CO2 emissions per year

Electricity comprises more the 70% of the total life cycle cost of acompressor

The cost of compressed air…it’s not free

9 4th Sept 2010

VSD – Variable Speed Drive

10%20%

energyenergy

maintenancemaintenanceinvestmentinvestment

> 70%

Energy savings Facts & Figures

10 4th Sept 2010

VSD – Variable Speed Drive

With VSD energy savings of 35% or more can be realized over traditional compressor regulation…

Energy savings – the Potential

11 4th Sept 2010

VSD – Variable Speed Drive

Key factor: fluctuation in air demand

Defines operation & power consumption

Air consumption in a compressed air systemis proportional to the amount of equipmentin use depends on the hour of the day or the dayof the week

Key factor: fluctuation in air demand

Defines operation & power consumption

Air consumption in a compressed air systemis proportional to the amount of equipmentin use depends on the hour of the day or the dayof the week

Slide 6 of 34

Energy savings , Where do they come from ?

12 4th Sept 2010

VSD – Variable Speed DriveWHY VSD ?

Match compressed air supply to exact demand …

… with minimum energy spendings.

MondayTuesdayWednesdayThursdayFridaySaturdaySunday

l/s

hour

50

100

150

200

250

Typical air demand pattern

13 4th Sept 2010

Air Demand Profile n°3

0

20

40

60

80

100

120

140

0:15

1:30

2:45

4:00

5:15

6:30

7:45

9:00

10:1

5

11:3

0

12:4

5

14:0

0

15:1

5

16:3

0

17:4

5

19:0

0

20:1

5

21:3

0

22:4

5

0:00

Time

Cap

acity

in l/

s

SundayMondayTuesdayWednesdayThursdayFridaySaturday

Air Demand Profile n°1

0

20

40

60

80

100

1200:

15

1:30

2:45

4:00

5:15

6:30

7:45

9:00

10:1

5

11:3

0

12:4

5

14:0

0

15:1

5

16:3

0

17:4

5

19:0

0

20:1

5

21:3

0

22:4

5

0:00

Time

Cap

acity

in l/

s

SundayMondayTuesdayWednesdayThursdayFridaySaturday

Air Demand Profile n°2

0

20

40

60

80

100

120

140

0:15

1:30

2:45

4:00

5:15

6:30

7:45

9:00

10:1

5

11:3

0

12:4

5

14:0

0

15:1

5

16:3

0

17:4

5

19:0

0

20:1

5

21:3

0

22:4

5

0:00

Time

Cap

acity

in l/

s SundayMondayTuesdayWednesdayThursdayFridaySaturday

Peak load determines the compressor selection

Average load determines the

compressor’spower

consumption

88%

12%

WHY VSD ? FEW TEST RESULTS

VSD – Variable Speed Drive

14 4th Sept 2010

Why VSD – The Conclusion

For Variations in demand VSD is ultimate Energy Saver

15 4th Sept 2010

How VSD works - Basic control PhilosophyFREQUENCY CONVERTER

ELEKTRONIKON MK V

PRESSURE SENSOR

SCREW ELEMENT VSD MAIN MOTOR

AIR

NET

AIR DELIVERY

SET POINT

The system targets a constant delivery pressure (setpoint)

16 4th Sept 2010

How VSD works - Animation

17 4th Sept 2010

Fixed Speed vs VSD compressor

18 4th Sept 2010

Modulating Control Variable Speed Control

POWER V/S CAPACITY COMPARISONSUCTION MODULATION CONTROL & VSD CONTROLBENEFIT 1 : POWER CONSUMED = DEMAND REQUIRED

VSD Benefits

19 4th Sept 2010

Soft start and stop operation…

no starting current peaks

soft starting and stopping at a controlled acceleration and deceleration time

no penalties for starting current peaks

unlimited restarting meaning complete elimination of unload energy consumption

less stresses on electrical and mechanical components

Starting Current Comparison

0

100

200

300

400

500

600

700

800

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

seconds

% F

ull L

oad

Cur

rent

Star DeltaDOL

Soft StarterVSD

VSD – Variable Speed DriveBENEFIT 2

20 4th Sept 2010

BENEFITSNo pressure over-shootsLess energy cost…lower working pressureHigher process stability

Customer ProcessPressure

Pressure - VSD -1.45 psigPressure - centrifugal - 4 psigPressure - standard load-unload -7 psig or more!

7 psig

VSD – Variable Speed Drive

BENEFIT 3 :Precise pressure control…stableprocess…constant pressure control

21 4th Sept 2010

VSD – Variable Speed Drive

Electro Magnetic Compatibility

It is defined as the “compatibility of electronic equipment with the electromagnetic environment, in which they are working”

There are two parts of EMC:

-The equipment should be so designed that it does not interfere with the working of other equipment.This constitutes control

-The equipment should not be disturbed by electromagnetic emissions by other equipment. This is called immunity

VSD equipment, if uncontrolled, emits electromagnetic waves which will interfere with instrumentation signals and other equipment. If unprotected it is also susceptible to external electromagnetic waves.

BENEFIT -4

22 4th Sept 2010

CONCLUSIONSVSD compressors are designed for maximum reliability– 100 % designed and tested for Electro-Magnetic Compatibility

EMC certificate of EU – the most stringent standard

Line reactor and RFI filter included

All motors are designed for VSD and are protected against bearing currents

– Integrated controls for compressor + converter

Converter is protected against overload by ElektronikonStart/stop and pressure control by the converter and the Elektronikon are fine-tuned during design

– The compressor is mechanically adapted for the complete speed range

No speed windows for vibrations

Changes to oil circuit for the right oil pressure/temperature

VSD – Variable Speed Drive

23 4th Sept 2010

VSD – Variable Speed DriveBENEFITS

Energy savings

Low starting currents

No peak torques

Constant pressures

Low average rpms

High power factors at all loads

Electronic gearing

Large turn down ( Can be used for min – max flow rates )

Integrated design

24 4th Sept 2010

VSD – Variable Speed Drive

Atlas Copco is market leader in VSD screw compressors, Supplied first VSD screw compressor in 1994, Sixteen years experience in VSD screw compressors

Atlas Copco manufacture integrated VSD screw compressors in various capacities in lubricated and oil free range

Today, 25 out of 100 screw compressors sold are VSD and expected to be 40 % in next three years

ATLAS COPCO VSD

25 4th Sept 2010

Who and When should opt for VSD Compressor

Plants having varying demand of Air (per day / per week basis)

Plants having multiple Piston compressor installations.

Plants having very old compressor installations, thereby consuming more energy.

Ideally one should opt for VSD compressor while setting up a new plant. (1 compressor out of the bank can be VSD)

When power cost is very high.

In any case, its never too late to save Energy.

26 4th Sept 2010

How Atlas Copco can help you

MBoxLite: By studying your plant Air consumption pattern with a very good Tool called MBoxLite. It measures the Air demand pattern and suggests possible saving.

VSD Calculator program : Payback period can be arrived at by entering basic data provided by plant user.

27 4th Sept 2010

References -Two Random cases

1 Rational Business Corporation, Bahal Garh Chowk,Sonepat 132101

Around 10 kwh/hour, Earlier customer was using competiton screw air compressor.

Additional Investement for VSD Rs. 3,00,000/-

12 months Mr. Ashok Kumar Gupta, Joint Managing Director, ashok@desmat.com, 09811030019

2 MERINO PANEL PRODUCTS LTD, 44KM STONE, DELHI-ROHTAK ROAD, VILLAGE ROHAD, BAHADHURGARH-HARYANA

Around 12 kwh/hour, Earlier customer was using reciprocating air compressors.

Additional Investement for VSD Rs. 2,50,000/-

8 Months Mr. B C Dua, Technical GM, merinorohad@merinoindia.com, 09812027334,

Contact details of the company

S No Company at which

implemented

Investment (Rs Lakhs)

Approx Payback Period

(Months)

Energy Saving achieved

28 4th Sept 2010

Partial List of customers benefited with VSD -2009

29 4th Sept 2010

LEED Certificate for VSD

30 4th Sept 2010