2004-0804TX technical archives www.trictrenchless.com TRIC Training Log: 08-04-04 Client: ARS Rescue Rooter, Dallas, TX Job: Residence, to rear property line, replacing 4” VCP Pull: two spurs, downstream / 10’ & 25’ / 4” / SDR17

2004 0804 Tx

Embed Size (px)

Citation preview

Page 1: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

TRIC Training Log: 08-04-04

Client: ARS Rescue Rooter, Dallas, TX

Job: Residence, to rear property line, replacing 4” VCP

Pull: two spurs, downstream / 10’ & 25’ / 4” / SDR17

Page 2: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

We at TRIC Tools have specific requirements for the use and maintenance of our equipment with regard to safety and efficiency on the job. Our written and verbal recommendations coincide with safety regulations set by local, state, and national government agencies. Our

clients may have standards over and above industry regulations. However, the safety equipment, apparel, and operating procedures

demonstrated by our clients in this presentation may or may not comply with above mentioned government regulations.

Page 3: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

Preparation: Have plenty of wood on hand for every pull. 2” x 4”, 4” x 4”, and 4” x 6” sizes are best, in 2’ to 3’ lengths for resistance cribbing, and 1’ lengths for pulley support.

Page 4: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

Two pulls: Two lateral spurs join at pit where worker is digging. Rear property line is to right; main runs down service alley. This pull is less than 10 lineal feet, but still saves a lot of

manual digging in hard Texas “white rock” soil.

Page 5: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

First pull: Roughly 25’ under concrete patio from west lateral spur exit (dirt mound) to intersection with east spur (worker with shovel).

Page 6: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

Property line: Pulling pit about 4’ deep.

Page 7: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

Spur junction: West spur (upper left) meets east spur (top) just inside edge of concrete patio slab. First pull set up against west spur wall of pit.

Page 8: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

Trimming pipe

Page 9: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

Fusion jig: Remove trimmings after each facing.

Page 10: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

Staging area: Find an area as flat and unobstructed as possible to fuse pipe.

Page 11: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

Cooling time: After fusing, allow joints to cool for 10 minutes (SDR17 4” & 6”) before removing from jig. See pipe manufacturer’s specs for more detail. Also, protect trimmer blades

(above) by setting trimmer wheel down on edge rather than flat as shown.

Page 12: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

Good weld.

Page 13: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

First pull: Watching for the cable clevis sheath (terminator) to appear at pulley plate.

Page 14: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

Arrival: Clevis sheath (in shadow under resistance plate bolt) just visible between pulley plate and pulley wheel. Keep this area free from debris to allow clear view of cable at all times,

so as not to pull cable sheath under pulley wheel. Note east spur above pulley.

Page 15: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

West spur done: Removing clevis bolt.

Page 16: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

Pull #2: Cribbing and pulley support.

Page 17: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

Entry: Ready to start pulling pipe.

Page 18: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

Going… Assist each entry to assure that it is as direct and unobstructed as possible.

Page 19: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

Going…

Page 20: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

Gone: In more difficult or angular entries, assist pipe entry by standing on pipe or otherwise flexing it to be in line with old pipe.

Page 21: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

During pull: After tension is applied and ram is stable, get out of the pulling pit.

Page 22: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

Disconnecting ram: Ready for extender cage.

Page 23: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

Resistance plate: Some users find it handy to cut out a copy of the resistance plate using 1” plywood. A wood template can be used to size up pulling pits as they are being dug (rather

than lifting the metal plate in and out of the pit).

Page 24: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

Extender cage: With a straight and clean pulling wall, often there is no need for cribbing between cage and earth. In this instance, ground is dry and solid.

Page 25: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

Ram assembly: A pit roughly 4’ in length allows ample space for using the extender cage. When the pits must be shorter, extra wood cribbing is used instead of the cage.

Page 26: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

Last foot: Head assembly freed from earth.

Page 27: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

Ram care: Find a clean place to set ram during job (such as a small piece of plywood). Keep jaws clean and protect chrome rods from nicks and deep scratches by keeping ram in

contracted position when not in use. (Damaged rods can cause leaks in hydraulic seals.)

Page 28: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

Pull complete: Cage alone (without extra cribbing) provides enough extension to free bursting head and expose pipe to trim minimum length behind PE cap.

Page 29: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

Release: Cable disconnected from head assembly.

Page 30: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

Spur junction: West spur (right) and VCP east spur (bottom, barely visible) ready to join new lower lateral.

Page 31: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

Cover up: New house cleanout at west spur.

Page 32: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

Clean up: Two pulls, three holes, small yard.

Page 33: 2004 0804 Tx

2004-0804TX

technical archives

www.trictrenchless.com

Dedicated van: One vehicle should contain all necessary pulling equipment.