Range
WeightankaWireanka
Accessanka
1
Weightanka/Wireanka/Accessanka
Contents
Features common to all Kee Anchor® productsWeightanka detailsWireanka detailsAccessanka detailsInspection and CertificationTestAny questions?
2
Weightanka/Wireanka/Accessanka
3
Class E Deadweight
Anchor Device to EN 795:1996
ISO 14567
Deadweight Anchor System for use as Intermediate and Extremity Anchors
for Class ‘C’ Horizontal, Flexible
Anchor Systemsto EN 795:1996
Class B & E Portable
Deadweight Anchor system for
Rope Access to EN 795:1996,
ISO 14567
Weightanka/Wireanka/Accessanka
Features
Will not move more than 1,000mm when arresting a fall
For roofs with a pitch of up to 5 degrees
Suitable for wet or dry roof surface
Easy and quick assembly
Galvanised to BS EN ISO 1461
4
Weightanka/Wireanka/Accessanka
5
Base weights
Base weights fully encased in rubberRubber moulding means base weights aren’t prone to peelingUnique design adds to performance.Reduces thermal bridging
Weightanka/Wireanka/Accessanka
6
Galvanised Counter weightsEach counterweight weighs 25kg and incorporate carrying handlesDifferent roof types require different Counterweight quantities
Weightanka/Wireanka/Accessanka
7
PlacementEN795 requires all dead weight anchor devices to be positioned 2.5m from any roof edge, open void or fall hazard.Do not position in areas where there is a risk of contamination or accumulation of waterDo not position where any system component could be affected by oil, grease or algaeIce and snow must be cleared from base, do not use if risk of frost or in freezing conditionsOn Gravel covered roofs, brush gravel to allow anchor bases direct contact with roof material
Weightanka/Wireanka/Accessanka
8
PlacementRoof Types- Up to 5º Pitch
ConcreteAsphalt Mineral Felt Stone chippings
Single ply membrane (Smooth)
Steel cladding Single ply membrane(Embossed)
Weightanka/Wireanka/Accessanka
9
Placement
An exclusion zone should be established around the Anchors working area into which no one should be allowed unless connected to the Deadweight (or other appropriate anchor, if one exists).
The exclusion zone should be designated by some form of marking or barrier, e.g. KEEMARK demarcation system.
Weightanka/Wireanka/Accessanka
10
Limitations
Must be used with PPE that limits the MAF to 6kN
Do not use in high winds.
WEIGHTANKA Not suitable for supporting cable systems, Use WIREANKA
Roof structure suitability to be checked by structural engineer (especially with Wireanka)
Weightanka/Wireanka/Accessanka
11
Fall Arrest fall distancesThe clearance height below the feet of the user to the first obstacle in the path of a potential fall must be at least what is required by any PPE used in conjunction with the Weightanka system, plus 1m to allow for potential movement of the system itself.N.B. Distance ‘D’ will be increased if Rope Adjuster or Retractable Lanyard used dependent on Manufacturers specification.Be aware of factors reducing fall clearance e.g. cars, other buildings, forktrucks, pedestrians. Recommend cordoning off area below work area. E.g. where A= 5m, B= 2.5m, D= 5m–2.5m +
1m= 3.5m E= 1.75m F = 2m G = 1mTotal fall clearance required = 8.25m
Weightanka/Wireanka/Accessanka
12
Fall Restraint
Combination of anchor position and PPE supplied ensures no user is able to reach a position of 0.5m of any roof edge, roof open or other fall hazard
Weightanka/Wireanka/Accessanka
13
Cleaning/StorageThe assemblies should be kept clean, using detergent if necessary, by wiping or hosing down with clean water and dried.If disinfecting is deemed necessary please check with Kee Safety that disinfectant will not cause damage to equipment or PPEStorage should be in a dry, chemically inert environment, away from sources of damage and stored in such a way that dismantled products will not become lost or misplaced.Where the Weightanka has been left in position an optional cover is available.
Weightanka/Wireanka/Accessanka
14
Before installation
It is strongly recommended that installers assemble and disassemble one in a place of safety, away from the worksite, to familiarise themselves with:
the product the assembly instructionsterms used to describe the various parts the markings on the product.
15
WeightankaClass E Deadweight
Anchor Device toEN 795:1996ISO 14567
CE Certified to PPEDirective
16
WeightankaPortable, Non Penetrative, Temporary or permanent
solution
Ideal for Where Roof build up is unknownNo Roof Alterations requiredGood for refurbishment projectsNo part of the Weightanka weighs more than 25kg
Performance relies solely on it’s own mass, and the friction between itself and the roof
surface.17
WeightankaNumber Of Users
Fall Arrest- Single User
Restraint- Two UsersTell Kee Safety at time of purchasingSupplied with 2nd Eyebolt & Restraint PPE disc.
18
WeightankaNumber of weights250kg (Six Galvanised weights) assembly for:
Asphalt Mineral Felt Concrete (Brushed) Stone chippings on Bitumen
300kg (Eight Galvanised weights) assembly for: Single ply membrane (Smooth)Steel cladding (Brushed) Stone chippings on Mastic
400kg (Twelve Galvanised weights) assembly for: Single ply membrane (Embossed)
For roofs of up to 5º pitch19
WeightankaAssembly
TOOLS REQUIRED FOR ASSEMBLY:
12mm A/F Hex Allen key
# 20
WeightankaIdentification Labels
# 21
22
WireankaDeadweight Anchor
System designed for use as Intermediate and
Extremity Free-Standing Anchors
for Class ‘C’ Horizontal,
Flexible Anchor Systems to EN 795:1996 and
BS 7883
CE Certified to PPEDirective
23
Wireanka
A system of deadweight anchor devices designed to support EN795 Class C Horizontal flexible safety lines.
For use on Flat roofs (less than 5º pitch), in temporary situations where it is preferable not to penetrate the roof.
Available Free Fall and edge distances sets system parameters
24
WireankaNumber of weights (Extremity anchors)300 kg (Eight Galvanised weights) assembly for:
Asphalt Mineral Felt Concrete (Brushed) Stone chipping
350kg (Ten Galvanised weights) assembly for: Steel cladding
400kg (Twelve Galvanised weights) assembly for: Single ply membrane (Smooth)
500kg (Sixteen Galvanised weights) assembly for: Single ply membrane (Embossed)
For roofs of up to 5º pitch, N.B. Check structural suitability of roof
# 25
WireankaLayout options
SINGLE EXTREMITY ANCHORS
Fall Arrest for a single user (with option of extra user if kept in restraint in a separate span)
-Or alternatively-
Fall Restraint for up to 3 users (maximum 2 users in a single span)
26
WireankaTYPICAL LAYOUT-Single Extremity/Corner Anchor
27
WireankaLayout options
DOUBLE EXTREMITY/CORNER ANCHORSFall Arrest for 2 users in separate spans (with option of 2 extra users per span if kept in restraint)Double Extremity Anchors are joined by specially designed connection kitsBoth layouts use single 250kg intermediate anchors (400kg on embossed single ply)
28
WireankaTYPICAL LAYOUT-Double Extremity/Corner Anchor
MAXIMUM OVERALL SYSTEM LENGTH 100m
29
WireankaDouble Extremity/Corner Anchor Connecting Kit
30
WireankaHorizontal Lifelines ComponentsEnd Fitting
Details of Swaging tool available from Kee Safety31
WireankaHorizontal Lifelines ComponentsCorner Bracket
Intermediate Bracket
32
WireankaHorizontal Lifelines 8mm Stainless Steel wire system
1. Cut wire to length2. Slide through Intermediate/ Corner brackets3. Swage end fittings and test (if line length known
Kee Safety can factory swage ends).4. Bolt Ends/Intermediates/Corners to Pedestals to
35 Nm
33
Wireanka
ALL SYSTEMS
Min. Edge Distance 2.5M 2.5M 3.0M 3.0M 4.0M 4.0M
Min. Free Fall Distance 5.2M 5.4M 5.8M 6.2M 6.6M 7.2M
MAX SPAN 5M 6M 8M 10M 12M 15M
Edge distances and maximum spans
FALL ARREST SYSTEMS
FALL RESTRAINT
Up to 10 m spans all systems have a minimum edge distance of 2.5m
# 34
WireankaComponent parts4- Rubber Weights6,8,12 or 16 Galvanised
Weights (depending on roof surface)
4- Locating Pins4- ‘R’ Clips2- Cross Arms1- Stabiliser Arm1- Pedestal, tapped
M12 to accept wire system component
1- M20 Countersunk Socket Screw
1- Tommy Bar1- PPE Disc (Fall Arrest
or Restraint)1- Polywasher
#35
WireankaIdentification Labels
# 36
WireankaIdentification LabelsCalculation Software
37
38
Portable Deadweight System for Rope
AccessConforms to BS EN 795, & ISO 14567 class B&E
CE Approved to PPE Directive
Single user for Roped Access applications
Two users in a rescue situation
Accessanka
39
FeaturesSeparate anchor points for working line and back up lineInternal force balanced system allows the assembly to remain static, even when arresting the fall of both worker and rescuerRequires no attachment to structural membersEasily moved across roof surface, removing need for multiple attachment pointsRope lines held away from edge of building reducing risk of abrasionProvides full fall arrest protection before approaching edge
Accessanka
40
Features
Used with a 250kg Weightanka Assembly for any roof type up to 5º pitch
Sold separately for use with existing Weightanka or as complete system
Aluminium, galvanised and rubber coated parts, requiring minimum maintenance
Accessanka
41
UsageAccessanka is an accessory to Weightanka and must always be used in combination with it.
This combination provides a mobile deadweight anchor device for use in rope access systems in accordance with:
Industrial Rope Access Trade Association (IRATA) guidelines
and/or:BS7985:2002 – Code of practice for the use of rope access methods for industrial purposes
Accessanka
42
AccessankaUsage
Ensure both working and Backup lines are secured to BOTH eyebolts
43
AssemblyAssembly consists of screwing the Accessanka together using stainless steel M10 nuts and boltsEach nut and bolt have thumb wheels for ease of assembly Modular assembly, no part longer than 2m. Complete assembly weighs 21kg
Accessanka
44
Accessanka
Accessanka assembly
45
Accessanka
Accessanka assembly
Accessanka placementHorizontal rope guide must be positioned to allow the lines to hang free, without them touching the edge of the roof or the side of the building below.
Centre of the Weightanka pedestal is positioned 3.3m from the roof edge. Correct leg position is inside the parapet wall at the roof edge, approximately 260 mm from the vertical face of the building.Adjust the position of Weightanka, if necessary, to achieve required position.AND AT LEAST 2.5m AWAY FROM ANY OTHER ROOF EDGE, OPENING OR FALL HAZARD
Accessanka
47
AccessankaDISTANCE FROM ROOF EDGE
48
AccessankaIdentification Labels
#49
50
Weightanka/Wireanka/Accessanka
51
Pre-use checksPositioned as instructed in EN795In case of fall, ensure fall will be unobstructed and sufficient distance is maintainedBase plates, suction cups in direct contact with roof surfaceCorrect number of weights used for roof typeCheck locking pinsRoof is ≤ 5ºMeans of connection (e.g. Lanyard) is not in contact with sharp edgesSurface is clear of oil, algae, ice, snow and standing waterRoof is structurally suitable and shows no sign of damageAnchor or components shows no sign of damageThreads and Eyebolt correctly tightened
SHOULD ANY DOUBT ARISE REMOVE FROM SERVICE(Full details in Assembly & Operating Instructions)
Weightanka/Wireanka/Accessanka
52
Interim checks (in addition to pre-use checks)After each week of constant use, every six weeks of intermittent use and on each occasion of re-assemblyInspect for signs of corrosion, wear, distortion or other defects on all partsRubber base is fully bonded to steel and no damage to suction cups. Remove any algae.Check the warning notices are intact and legible.
SHOULD ANY DOUBT ARISE REMOVE FROM SERVICE
(Full details in Assembly & Operating Instructions)
Weightanka/Wireanka/Accessanka
53
Thorough examination (Detailed examination) Weightanka/Wireanka to be carried out as a minimum
annuallyAccessanka six monthly (LOLER regulations)Recorded on Record cardCarry out all checks as interim inspection, plus:
No wear or distortion of holes through which pins and bolts are passedNo deformation of pins or bolts or of their threads No evidence that Weightanka/Wireanka has arrested fall e.g. scrape marks on roof, deformation of pedestal, cross arms, stabiliser, eyebolt etc.(Accessanka only) Check for wear of the horizontal rope guides. If depth of groove greater than 1mm, outer beam should be returned for repair.
SHOULD ANY DOUBT ARISE- REMOVE FROM SERVICE(Full details in Assembly & Operating Instructions)
Weightanka/Wireanka/Accessanka
54
Example of inspection record
Weightanka/Wireanka/Accessanka
55
Supporting Documentation/More informationIdentification labelsAssembly and operating instructionsInspection recordsMethod statement/risk assessments (users responsibility)Sales Literaturewww.keesafety.com
Weightanka/Wireanka/Accessanka
56
Questions1. What’s the maximum distance a
Weightanka/Wireanka is allowed to move in the event of arresting a fall?
2. What’s the maximum distance an Accessanka moves in the event of arresting a fall?
3. What’s the maximum roof pitch a Kee Anchor product can be used on?
4. What is the minimum edge distance a Kee Anchor product can be placed from a fall hazard?
5. What must be done to a gravel covered roof when placing a Kee Anchor product?
6. Where can the information on the correct weights for different roof types be found?
7. What will be supplied with a Weightanka should it be specified as ‘Fall Restraint’?
Weightanka/Wireanka/Accessanka
57
Questions8. What are the maximum periods for detailed
inspection/certification for: WEIGHTANKA/WIREANKA
9. What are the maximum periods for detailed inspection/certification for: ACCESSANKA
10. A Wireanka system with single extremity anchors is for how many users for fall arrest?
11. What weight is the intermediate anchor for the Wireanka system for all roof types (except embossed single ply).
12. Name two things that differentiates the Weightanka from the Wireanka
13. How many users can an Accessanka accept?14. What qualification must an Accessanka user
possess?
Weightanka/Wireanka/Accessanka
58
Answers1. What’s the maximum distance a Weightanka/Wireanka is
allowed to move in the event of arresting a fall? 1 metre2. What’s the distance an Accessanka moves in the event of
arresting a fall? It doesn’t move3. What’s the maximum roof pitch a Kee Anchor product can
be used on? 5 degrees4. What is the minimum edge distance a Kee Anchor product
can be placed from a fall hazard? 2.5m5. What must be done to a gravel covered roof when placing
a Kee Anchor product? Clear gravel, so rubber coated base plates are in direct contact with roof surface
6. Where can the information on the correct weights for different roof types be found? Identification labels, Assembly & Operations Instructions, Kee safety literature, Website
7. What will be supplied with a Weightanka should it be specified as ‘Fall Restraint’? An extra eyebolt and a Fall Restraint PPE disc
Weightanka/Wireanka/Accessanka
59
Answers
8. What is the maximum period for detailed inspection/certification for: WEIGHTANKA/WIREANKA 12 months
9. What is the maximum period for detailed inspection/certification for: ACCESSANKA 6 months
10. A Wireanka system with single extremity anchors is for how many users for fall arrest? One
11. What weight is the intermediate anchor for the Wireanka system for all roof types (except embossed single ply). 250kg
12. Name two things that differentiates the Weightanka from the Wireanka Pedestal height & labels
13. How many users can an Accessanka accept? Two14. What qualification must an Accessanka user possess?
IRATA/FISAT/Qualified Rope Access Technician