Техническое описаниеГосударственный реестр средств измерений № 46681-11

Серия Network Master Базовый блок MT9090A

Модуль анализатора коротких линий MU909011A3Одномодовый режим, 780 и 1550 нм

НПО «РАДАР» www.radar1.ru

Page 2: Анализатор коротких оптических линий mu909011a3-052

2 Product Brochure l MT9090A/MU909011A3

Last Mile Testing Redefined!MT9090A/MU909011A3 OverviewUntil now, the right tool just didn’t exist for cost effectively testing short fibers. Handheld OTDRs and Fault Locators lacked the resolution and in such short spans while mini-OTDRs were too large, too expensive and too complicated. The new MT9090A from Anritsu finally addresses this need by providing all of the features and performance required for installation and maintenance of short fibers in a compact, modular test set. The MT9090A represents an unmatched level of value and ease of use, while not compromising performance. Data sampling of five centimeters and deadzones of less than one meter, ensure accurate and complete fiber evaluation while a simple testing sequence requires only one key press to initiate – allowing anyone to make error-free measurements.The MT9090A represents a new era in drop cable and premise testing. Its ease of use, low price, high-resolution and size make this the perfect product for “last mile” and intra-building testing.

Key Features•Unique,purpose-builtsolutionforshortfiberapplicationssuchasFTTxdrop,MDUriserandCOcables•Exclusive,integratedlaunchfiberprovidesaccurateinitialconnectormeasurementwithoutexternaldevices•Highresolution,widescreencolordisplaythatiseasytoreadindoorsorout•Fixedparameterssimplifyoperationandensureproperset-up–justpress“START”•Highresolutionandextremelyshortdeadzonesensurethoroughshortfiberevaluation•Rugged,sealeddesignprovidesyearsofserviceinthemostchallengingenvironments•Modularplatformensuresmaximumreturnoninvestment•Compactandlightweightdesignformaximumportabilityinthefield•CompleteFTTxmaintenancetoolincludingopticalpowermeterandvisiblesource“redlight”•Unique780nmwavelengthforin-servicemaintenanceofPONswithoutfilters•Highperformancewithoutahighprice•Basicmultimodefibertestingwith1550nmsinglemodemodule

Page 3: Анализатор коротких оптических линий mu909011a3-052

Product Brochure l MT9090A/MU909011A3 3

Realizing that short fiber premise applications such as FTTx drop cables, intra-building riser cables and cell towers have different testingrequirements,AnritsudesignedtheMT9090Afromthegroundup.Itfeatures5cmresolutionforaccuratemappingofevents,deadzonesoflessthan1meter(3feet)andabuilt-in10m(30ft)launchfibertoensureeverythingisevaluated.

Purpose-Built for Short Fiber Applications

Quick Startup TheMT9090Aisreadyformeasurementinabout15secondsso productive work can start immediately.

Long Battery LifeSinceACpowerisnotalwaysavailablewhereyouneedit,especially at fiber pedestals, the MT9090A typically provides 3.5hoursoftestingonasinglecharge.Thiscoupledwithanoptional car cigarette lighter cord guarantees the MT9090A is ready when you are.

PortableWith its lightweight design and user friendly dimensions, the MT9090A is perfect for the outside plant environment and can easily be managed with one hand. The standard softcase with shoulder strap further increases portability when traveling from

the truck to the testing site.

RuggedWith no fans or vents to allow dust and moisture to enter the unit, the MT9090A was designed for the challenging outside plant environment.

Video Inspection Probe SupportWhen equipped with the optional connector video inspection probe(VIP),theMU909011A3becomesapowerfultoolforevaluatingconnectorcleanlinessandquality.Connectorendfaces can be safely viewed and images stored to document all aspects of your network.

4.3-inch Wide Screen Display for Easy ViewingThe high resolution, full color, 4.3-inch wide screen display is the perfect format for viewing OTDR results. It also provides excellent readability both indoors and outdoors.

1)4.3”highresolution,indoor/outdoorcolordisplay2)Dedicatedfunctionkeysforperformingtasks3)STARTkeyfortrueone-buttontesting4)Arrow keys for zooming, cursor movement and menu navigation5)SETtoselect/accept

6)Menukeyforeasyaccesstoset-upsandmassstorage7)Integratedpowermeter8)Visiblelaserdiode9)DualUSBportsforquickandeasydatatransfer

<1 m Dead Zone for Short Fiber AnalysisWithlessthan1mdeadzones,theMT9090Aisperfectforevaluating central office, FTTX and intra building cables.

No Experience RequiredWith the MT9090A, the expertise is built in. With an automated testingsequence,fixedparametersandPASS/FAILclassification, anyone can certify and troubleshoot drop cables or premise networks.

Page 4: Анализатор коротких оптических линий mu909011a3-052

4 Product Brochure l MT9090A/MU909011A3

Despite its size…it is not a toy!When buying products, you tend to choose ones that are innovative and from established companies. When you need to install and maintain optical networks, this shouldalsoapply.Withover50yearsofcombinedOTDRdesign,Anritsu,whichnowincludesNetTest,delivers the features that matter.Having been in the test and measurement business for a long time, we understand the importance of performance, portability, reliability, easy operation and of course price.

Real Time SweepingIn the field, real-time sweeping is often very useful to confirm correct fiber splicing and placement.

Integrated Launch FiberTofurthersimplifytesting,theMU909011A3has10m(30ft)offiber built-in so initial fiber connections can be verified without the need for additional patchcords or launch fibers.

Full Trace ViewThe user can also select to view the full trace for additional information or to initiate real time testing.

Event Table with User Defined ThresholdsPASS/FAILthresholdsforkeyacceptancecriteriasuchassplice loss, reflectance and total span loss can be set in the MT9090A allowing technicians to easily assess a fiber’s condition. Failing values are clearly highlighted in the event table alerting technicians of potential problems.

Visible Light SourceA visible laser diode “red light” to visually troubleshoot splices, connectors and the fiber management is also available.

Integrated Power Meter (through OTDR port)The power meter allows users to verify the presence of signals and then fault locate with one instrument – and without having to disconnect and move the fiber to another port.

Screen Capture FunctionScreenshotsaresometimesusefulforaddingtoreportssotheMT9090AfeaturestheabilitytosavescreenshotsasBitmapimages.

Multimode Fiber Testing (Option)Basicmultimodefibertestingcanbeperformedwiththe1550nmsingle mode module.

Simple Data StorageWithinternaldatastorageplussupportforexternalUSBmemory devices, the MT9090A is more than capable. Add to this auto file saving and naming for easy, error-free documenting of your network.

Common OTDR Data Format TheMT9090AsupportstheuniversalTelcordiaSR-4731formatmakingitcompatiblewithnotonlylegacyAnritsuandNetTestproducts, but with many other vendors data.

Easy “drag and drop” File TransfersWhentheMT9090AisconnectedtoaPCviaaUSBcable,theinternal memory can be directly accessed. Data can be selected,draggedanddroppedintothePCmemory,greatlysimplifying file transfers. The MT9090A also supports the use of USBmemorysticks.

Modular DesignThe MT9090A features a modular design allowing modules to be easily changed in the field. Users can interchange different wavelength fault locator modules or perform other optical network testing such as optical channel analysis with the availableCWDMchannelanalyzermodule.Operationisquitesimilar between modules so the user is immediately familiar with operation.

Mainframe

Module

Page 5: Анализатор коротких оптических линий mu909011a3-052

Product Brochure l MT9090A/MU909011A3 5

Installation and Maintenance SimplifiedSincetheMT9090Aispurposebuiltfortestingshortfiberspans,itshardwareanduserinterfaceareoptimizedforsimplicity.A customizable testing sequence automates testing and guides novice users.

Installation SimplifiedTheMU909011A3faultlocatormoduleprovideseasyandaccurateverification of drop cable installation. The user simply connects the fiberandpresses“START”fortrueone-buttontesting-allsettingsare fixed to ensure accurate and consistent results for any skill level. Uponcompletion,thelength,totallossandPASS/FAILstatusaredisplayed within seconds. A full event table of all characteristics is also shown providing additional information on the fiber under test.

Step 1 – Connect fiber and power on

Step 2 – Press “START” The connection check feature ensures that the fiber to be tested is properly cleaned and connected correctly.

Step 3 – Read ResultsTest results including all splices and connectors, as well as total fiberlength,lossandPASS/FAILstatusareshowninaneasytoread table.

A Unique Approach to In-Service MaintenanceSincemultipleuserssharethecommonfeedfiber,FTTxmaintenance becomes difficult when only one or two users are down. Traditionally,1625nmor1650nmwavelengthswereusedtotestactive fibers however these wavelengths typically need costly WDM couplers and filters in the network. As a unique approach to this, Anritsualsooffersa780nmFaultLocatormodulethatcanbeusedto troubleshoot in-service FTTx networks without costly filters and without disruption to other customers. This offers a clear advantage overPONspecificpowermetersthatonlyverifysignalpresencebutstill rely on an additional OTDR or fault locator to locate the cause. With the MT9090A, one box does it all !

Step 1 – Verify ONT Fault Step 2 – Disconnect fiber from ONT and connect

to MT9090AStep 3 – Verify signal presence and level Good signal – replace ONT No signal – press “continue” to launch fault locate test Low signal – press “continue” to launch fault locate test (780nmwillnotinterferewith1490nmor1550nm

transmissions)*1,*2

Step 4 – Review Results

*1:Atactualwork,Onlyusethe780nmOTDRafterconfirmingthatthereisnoeffectonthecustomer'scommunicationssystem.Anritsucannotguaranteeinadvancethattherewillbenoimpactoncommunications.*2:Fiberbendingloss(attenuation)cannotbedetectedatthe780nmwavelength.

Page 6: Анализатор коротких оптических линий mu909011a3-052

6 Product Brochure l MT9090A/MU909011A3

MT9090A Mainframe

Dimensions and Mass 190(W)×96(H)×48(D)mm(7.5”×3.8”×1.9”)(Includingmainframeandmodule)<800g(<2lbs.)(includingmainframe,moduleandbattery)

Display 4.3-inchTFT-LCD(480×272,withbacklight,transparenttype)Interface USB1.1,TypeA×1(memory),TypeB×1(USBmassstorage)

MU909011A3 Drop Cable Fault Locator Module

Model MU909011A3-052/062MU909011A3-050/060

SingleModeFiberTest MultiMode Fiber Test*12

Wavelength*1 780nm±20nm 1550nm±30nm UndefinedFiber Type 10µm/125µmSMF(ITU-TG.652) 62.5µm/125µmMMF

Distance Range 1.0km(3,000ft)or2.5km(8,000ft)set automatically

1.0km(3,000ft),2.5km(8,000ft)or10km(32,000ft)set automaticallly

Pulsewidth <10nsDynamic Range*2 >7.0dB UndefinedDeadzone Fresnel:<1m*3,Backscatter:<5m*4 UndefinedSamplingResolution 5cm(Distancerange1.0km),10cm(Distancerange2.5km)(IOR=1.50000),50cm(Distancerange10km)SamplingPoints 20001(Distancerange1.0km),25001(Distancerange2.5km),20001(Distancerange10km)DataStorage Internalmemory:40MB(upto800traces),External(USB):upto20,000traceswith1GBIORSetting 1.3000to1.7000(0.0001steps)Units ft, mFiberEventAnalysis Automatic,displayedintableformatbasedonuserdefinedPASS/FAILthresholds UndefinedLoss Modes 2pointloss,dB/kmOTDR Trace Format Telcordiauniversal(.SOR),issue2(SR-4731)

Other Functions

Integratedlaunchfiber:10m(30ft)ConnectorInspectionMicroscope(Optional);verifiesconnectorconditionandclealinessConnectioncheck:AutomaticcheckofOTDRtoFUTconnectionqualityLiveFiberdetect:verifiespresenceofcommunicationlightinopticalfiberRealtimesweep:<1sec(typical)

Languages Spanish,French,German,Italian,SimplifiedChinese,TraditionalChineseandEnglish

IntegratedOpticalPowerMeterWavelength1550nm,sameportasOTDRPowerrange:–5to–45dBm,Accuracy:±0.5dB*5,Maximuminput:+10dBm

VisibleLaserDiode Connector:2.5mmuniversal,Wavelength:650±15nm,Output:0±3dBmLasersafety:IEC60825-1:2007CLASS3R:MU909011A3-050/060/052/062*9(CW)

21CFR1040.10*11

PowerSupply 9VDC,100V(ac)to240V(ac),Allowableinputvoltagerange:90Vto264V,50Hz/60HzBattery NiMH,OperatingTime:3.5hours(typical)*6,RechargeTime:<3h*7

EnvironmentalConditionsTemperature, Humidity*8:0˚to+50˚C(Operation),–20˚to+60˚C(Storage),<80%(non-condensing)Vibration:MIL-T-28800EClass3,DustandDripproof:IP51

EMC EN61326-1,EN61000-3-2LVD EN61010-1

Laser safety IEC60825-1:2007CLASS1:MU909011A3-050/060/052/062*10

21CFR1040.10*11

Specifications

*1:@25°C*2:Averaging:10seconds,SNR=1,+25˚C*3:Returnloss:45dB,+25˚C(1.5dBdownfromthepeakofFresnel)*4:Returnloss45dB,Deviation±0.5dB,+25˚C*5:CWinput,–20dBm@1550nm,+25˚C*6:Backlightlow,Sweepinghaltedat+25˚C*7:+10˚to+30°C,PowerOFF*8:+10˚to+30°C(DuringRechargingbattery,PowerOFF)

*9:Safetymeasuresforlaserproducts Thisproductcomplieswithopticalsafetystandardsin21CFR1040.10and IEC60825-1;thefollowingdescriptivelabelsareaffixedtotheproduct.

*10:Safetymeasuresforlaserproducts Thisproductcomplieswithopticalsafetystandardsin21CFR1040.10andIEC60825-1;thefollowingdescriptivelabelsareaffixedtotheproduct.

*11:ExcludesdeviationscausedbyconformancetoLaserNoticeNo.50datedJune24,2007.

*12:MU909011A3-002MultimodeTestFunctioninstalledandselected.

Page 7: Анализатор коротких оптических линий mu909011a3-052

Product Brochure l MT9090A/MU909011A3 7

1) Select MainframeIncludesbatterypack,ACcharger/adapter,standardsoftcase,strapandprotector

Model/OrderNo. DescriptionMT9090A Mainframe(withcolorLCD)

2) Select Base ModuleIncludes printed operation manual

Model/OrderNo. Description

MU909011A3 DropCableFaultLocatorModule(withvisiblelaserdiodeandPowerMeter)

3) Select Module OptionModel/OrderNo. DescriptionMU909011A3-050 1550nm,singlemode,UPC,visiblelaserdiode,powermeterMU909011A3-060 1550nm,singlemode,APC,visiblelaserdiode,powermeterMU909011A3-052 780nm,singlemode,UPC,visiblelaserdiode,powermeterMU909011A3-062 780nm,singlemode,APC,visiblelaserdiode,powermeter

4) Select Connector AdapterOne adapter included at no charge – must be added as a separate line item.

Model/OrderNo. DescriptionMU909011A-037 FCConnector(UPC:Models-050and-052only)MU909011A-038 STConnector(UPC:Models-050and-052only)MU909011A-039 DIN47256Connector(UPC:Models-050and-052only)MU909011A-040 SCConnector(UPC:Models-050and-052only)

MU909011A-025 FC-APCConnectorkeywidth2.0mm(APC:Models-060and-062only)

MU909011A-026 SC-APCConnector(APC:Models-060and-062only)

5) Select Software OptionMust be added as a separate line item.Availableformodels-050,-060only

Model/OrderNo. DescriptionMU909011A3-002 Multimode Test Function

6) Select AccessoriesMust be added as separate line items.

Model/OrderNo. DescriptionG0203A ACadapter(Replacement)G0202A NiMHBatteryPack(Replacement)Z1580A*1 Protector&SoftCaseB0663A*2 ProtectorB0600B HardCaseB0601B StandardSoftCaseZ1023A StrapB0602A DeluxeSoftCase(forMT9090A)J1402A CarplugcordJ1530A SCPlug-inConverter(UPC(P)-APC(J))J1531A SCPlug-inConverter(APC(P)-UPC(J))J1532A FCPlug-inConverter(UPC(P)-APC(J))J1533A FCPlug-inConverter(APC(P)-UPC(J))J1534A LC-SCPlug-inConverter(forSM,SC(P)-LC(J))J1535A LC-SCPlug-inConverter(forMM,SC(P)-LC(J))W2988AE MU909011AOperationManual(Hardcopy)W2989AE MU909011AOperationManual(CD)OPTION-545VIP ConnectorInspectionMicroscope(×200,×400)MU909011A3-ES210 12monthextendedwarranty(total2yearswarranty)MU909011A3-ES310 24monthextendedwarranty(total3yearswarranty)

*1:Theprotector(B0663A)andstandardsoftcase(B0601B)fromaset. The protector includes a shoulder strap.

*2:Theshoulderstrapcanbeusedtohangtheinstrumentaroundtheneckwhile working.

7) Replacement AdaptorsMust be added as separate line items.

Model/OrderNo. DescriptionJ0617B FC(UPC:Models-050and-052only)J0618D ST(UPC:Models-050and-052only)J0618E DIN(UPC:Models-050and-052only)J0619B SC(UPCorAPC:allmodels)J0739A FC(APC:Models-060and-062only)

Ordering InformationPleasespecifythemodel/ordernumber,nameandquantitywhenordering.ThenameslistedinthechartbelowareOrderNames.TheactualnameoftheitemmaydifferfromtheOrderName.

B0601B Standard Soft CaseThis standard accessory accommodates the mainframe with fitted protector.

B0602A Deluxe Soft CaseFullNetworkMasteroperationwithoutremoval from the case. Providesexcellentprotectionforuseinhash conditions.This does not accommodate the mainframe if the protector is fitted.

B0600B Hard CaseThisaccommodatestwomainframes(withorwithoutfittedprotector),accessories(lightsourceorpowermeter,backupbattery,fibercleaner,etc.).

B0663A Protector (Standardaccessory)

MainframewithProtector

Page 8: Анализатор коротких оптических линий mu909011a3-052

MT9090 SeriesMU909020A OCA ModuleCompactCWDMchannelanalyzertoverifypowerlevels,driftandchannelpresenceofCWDMnetworks.MU909060A GigE ModuleDedicatedfieldtestsolutionforinstallationandtroubleshootingEthernetlinksin the access network.MU909014/15 µOTDRCompactOTDRforfullautomaticverificationofopticalnetworks,FTTH-PON,MetroandCore.

MT9083 Series ACCESS Master Mini-OTDRAll-in-onetesttoolforfiberconstructionand maintenance.

CMA5000a Multi-Layer Network Test PlatformA wide selection of test modules including GigabitEthernetand10GbpsEthernet.

CMA5 SeriesFor Optical Fiber Installation and Maintenance.

CMA 3000 All-in-one Field TesterTestofmanyinterfacesincludingEthernet

MU909020A

MU909014/15

MU909060A

CatalogNo.MT9090A-E-A-1-(10.00)PrintedinJapan02/OCT/2013ddcm/CDT

Page 9: Анализатор коротких оптических линий mu909011a3-052

16 Техническое описание ▌ MS9740A

Пожалуйста, обращайтесь:

Технические характеристики могут изменяться без дополнительного уведомления

папрffsrgsrgsrgs

РОССИЯ, 198152, Санкт-Петербург

Краснопутиловская ул., д.25

Тел./факс +7 (812) 600-48-89

Тел.: +7 (812) 375-32-44

www.radar1.ru

[email protected]