.. - 6, 144 51 - .: 210 2850573 FAX: 210 2849028
KAFFE S.A. - VENTILATION CENTER6 SITEIAS, GR-144 51 METAMORFOSI - ATHENS - GREECETEL.: +30 210 2850573 FAX: 210 2849028
e-mail: [email protected] web site: www.kaffe.gr - www.ventilation-center.com
2
014
- 201
5
!O . 250 ( 5.000 ) . , . , , ISO: 9001-2008 CE . ! 24 24 , , ! . !30 , , .
CD S&P EasyVent S&P
, .
-
site www.kaffe.gr
Copyright , - , , , . ( 2121/93 & 2557/97).
@@
Our product catalogue - Your productivity tool !Our product catalogue is the true evidence of our promise for improvement. More than 250 different types of products (almost 5000 product codes) are in the pages that cover all your needs. Also, you will find new products, technical information, as well as our already well known products. ServiceThe companys employees are always willing to answer to any question you may have, offer the most reliable solution to every ventilation problem and the best technical support. The companys aiming for high quality and certified products, is proved as the company follows all the directives, procedures and standards described at the ISO:9001-2000 certification for the companys organization and operation scheme, and the CE mark for the goods it produces. A store always open for youOur web site www.kaffe.gr offers 24hoursx7days information about our products. Through an easy navigation menu, you can easily select the product you wish, with pictures and details about it. There you can also find this catalogue -you hold in your hands- in electronic form. Ask you request electronically and we will contact you in no time! Competitive pricesBeing in the ventilation field for 30 years, we have the advantage to guarantee consistent product quality, spare parts repository, and the most competitive prices in the market, because we import exclusivity from major ventilation manufactures in the Eu-ropean Union, and we manufacture our products in our privately-owned industrial facility.
Feel free to ask for the companys CD-ROM that includes The KAFFE SA Product Catalogue that you have in your hands The Soler & Palau General Product Catalogue EasyVent calculation program of S&P Certificates
We are always by your side with Excellent, Competitive and Reliable products.
KAFFE SA - VENTILATION CENTR
O ... 1
c o n t e n t s
1
.
/
/
H / / MSc
M / /
/ / MSc
B
/
A Marketing
I / / Sc
o
O ...2
O ...
w w w k a f f e . g r
. 9
. 23
o . 39
. 51
. 133
. 151
. 157
. 173
. 205
. 215 .103
. 10 - 15
. 16 - 22
. 24 - 31
. 40 - 45
.52 - 60
. 61 - 66
. 67 - 73
. 74 - 82
. 83 - 89
. 90 - 94
. 116 - 132
. 95 - 102
. 32 - 38
. 46 - 50
. 134 - 150
. 152 - 156
. 158 - 166
. 167 - 172
. 174 - 178
. 179 - 183
. 184 - 188
. 189 - 192
. 193 - 197
. 198 - 204
. 206 - 208
. 209 - 211
.212 - 214
. 216 - 220. 104 - 115
O ...
. 221
. 235
. 251
- . 275
. 292
- . 339
. 392
(REFERENCES)
=
- . 297
- ()
c o n t e n t s
. 222 -226
. 236 -240
. 227 - 234
. 241 - 250
. 252 - 257
. 258 - 262
. 263 - 267
. 268 - 270
. 271- 274
- . 363
.340 - 341
.364 - 371
.372 - 376
.342 - 345
.346 - 352
. 377
. 378 - 283
. 384 - 387
. 388 - 391
.298 - 306
. 312 - 315
.307 - 311
.316 - 319
.320 - 325
.326 - 338
- . 353
.354 - 359
.360 - 362
.276 - 281
.282 - 286
.287 - 291
.292 - 296
O ...6
EEVS GG 66-68
,
,
standards. S&P - Ventilation Group
( , , , ,
.),
. ,
S&P.
...
, ,
.
S&P - Ventilation Group ( ,
, , , .),
.
FK
S&P - Ventilation Group
- - .
S&P - Ventilation Group
EC. , DCV (Demand Controlled Ven-
tilation systems) .
(HRU) (AHU)
.
.
S&P - Ventilation Group
ISO-14001 . -
- ....
( :01331)
O ... 7
EEVS GG 66-68
... !!!
.
.
DCV .
80 .
55% !
10 17.500 !
CO2
10 95 !
NEA ! !!!
TCDH
DOMEO
RADT FENA-CBP
AHU AHU-HYG AHU-DEXACU
FFCU
DAISY
AIRPUR MINIMAN MINIMAN ECONOMY ARM
COSMOS ECOHAND
VIVALTO RIVA COMFEE HYGROMATIC DG
FKHD 900S
SWF SILENT DECOOZEO
FENA-ROT FENA-HIE
FLEXEO ECOROOM CADS-HE
CTVB HP CAF CAB ECOWATT
45
108
122 126
143 146 148141
150
195
227 239 240 241
199 218
256 264 282 292
220
178154
128 130
110 112 114
49 61 71
188
O ... 9
plate mounted axial flow fansNEA !
!!!
9
c o n t e n t s
plate mounted axial flow fans
COMPACT HCFB/HCFT HCBB/HCBT
HXM
HXBR/HXTR
KAFB / KAFT
HIB/HIT
CGT / CHGT
HDT
TURBO
ELITURBO
ARTIC
10-11
12
13
14
15
16-17
18
19
20-21
22
O ...10
PLATE MOUNTED AXIAL FLOW FANS(Plastic or Aluminium Impeller)
COMPACT
IP:65
1.200 - 54.000 m3/h
rpm
MAX .WATT
m3/h
mm
dB(A) BAKg
mm
HCFB/TTIMH
HCBB/TTIMH
HCFB/4-250/H 1330 60 1.215 250 52 5 315 x 315 272,00 328,00
HCFB/4-315/H 1300 100 2.350 315 54 7 400 x 400 281,00 346,00
HCFB/4-355/H 1225 200 3.490 355 58 8 450 x 450 344,00 416,00
HCFB/4-400/H 1200 340 5.070 400 60 9 500 x 500 368,00 430,00
HCFB/4-450/H 1290 480 6.760 450 65 13 560 x 560 476,00 512,00
HCFB/4-500/H 1290 650 9.200 500 68 16 630 x 630 521,00 573,00
HCFB/4-560/H 1290 980 12.480 560 71 22 710 x 710 718,00 782,00
HCFB/4-630/H 1200 1700 17.060 630 72 25 800 x 800 814,00 847,00
HCB/4-710/H 1300 2200 22.150 710 75 27 900 x 900 - 867,00
HCBB/6-710/H 900 1300 16.500 710 66 27 900 x 900 - 861,00
HCBT/4-800/L-X(1,5kW) 1420 2300 24.960 800 79 37 1000 x 1000 - 1.058,00
HCBT/4-800/H-X(3kW) 1430 4200 31.140 800 82 52 1000 x 1000 - 1.183,00
HCBT/4-900/L-X (3kW) 1400 4400 35.000 900 83 96 1120 x 1120 - 1.304,00
HCBT/4-900/H-X (5,5kW) 1400 7200 45.000 900 87 112 1120 x 1120 - 2.233,00
HCBT/4-1000 L-X (3kW) 1400 4400 39.240 1000 84 67 1250 x 1250 - 1.504,00
HCBT/4-1000/H-X (5,5kW) 1460 7200 54.000 1000 87 95 1250 x 1250 - 3.072,00
IP: 65 (230/400V-50Hz). 2 HCBT/4-800, HCBT/4-900, HCBT/4-1000 IP:55. M F -40C +70C, 800, 900 1000 -20C +40C
: , , , , , ..
: 250 630 REB-5000W -52. 630 & 710 230V . 400V INVERTER.
: (PER), (GRI), (SQA).
: 2, 6 8 (2900,900,700 rpm), ( ), , Exll2G EExellT3 400 V.
HC = COMPACT
F = PVC (plastic impeller) B = (die cast aluminium impeller)
= (220V)
4 = (number of poles)
HC F B / 4 - 250250 = mm (nominal diameter in mm)
= (380V)
., .
O ... 11
plate mounted axial flow fans
IA HCFB (mm) DIMENSIONS HCFB (mm)
Configuration for models 800 to 1000
O ...12
rpm. .
WATT
m3/h
mm
dB(A) g
mm
HXM-200 1300 16 500 200 36 1,8 266 x 266 120,00
HXM-250 1300 22 900 250 42 2,2 333 x 333 138,00
HXM-300 1300 34 1.400 300 48 3,2 400 x 400 154,00
HXM-350 1300 40 1.800 350 53 4,3 465 x 465 197,00
HXM-400 1300 170 3.000 400 57 7,3 500 x 500 252,00
HXM
Type A B C D E F G
HXM-200 222 266 9 205 85,5 19 211
HXM-250 275,5 333 9 255 92,5 31 261
HXM-300 336,5 400 10,5 305 92,5 35,5 311
HXM-350 390 465 10,5 361 105,5 34,5 371
HXM-400 420 500 10 400 141,0 52 414
(mm)
PLATE MOUNTED AXIAL FLOW FANS
230V/50 Hz IP:44.
+40C. . O 200, 250, 300, 350 50cm. O -400 , IP:44, F .: , , ..
: REB-2,5 REB-5000W.
: (PER), , (SQA).
500 - 3.000 m3/h
HXM 400
rpm. .
WATT
m3/h
MAXoC
mm
mm
dB(A) g
HXBR/4-250 1450 40 930 +60 250 315 x 315 45 6,5 222,00
HXBR/4-315 1400 120 2.074 +40 315 400 x 400 53 7,0 239,00
HXBR/4-355 1400 120 2.970 +60 355 450 x 450 59 7,5 263,00
HXBR/4-400 1360 290 5.080 +65 400 500 x 500 60 9,0 282,00
HXBR/4-450 1370 410 7.649 +50 450 560 x 560 64 11,5 469,00
HXBR/4-500 1350 995 9.957 +70 500 630 x 630 69 16,0 580,00
HXBR/4-560 1300 1300 12.460 +45 560 710 x 710 70 21,5 797,00
HXBR/4-630 1320 1300 14.518 +40 630 800 x 800 72 24,0 904,00
HXBR/6-710 835 850 16.668 +40 710 900 x 900 66 27,0 957,00
O ... 13
plate mounted axial flow fans
SINGLE PHASE THREE PHASE
ANIKOI E HXB
PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR
HXBR - 230V/50Hz - HXTR 400V/50Hz . IP: 54 - . F -40C, +70C ( ).
, .
Underwriters Laboratories Inc (USA).
: B , , , , , , .. 95% RH.
: 230V REB-5000W /4-560, /4-630, /4-710 400V INVERTER.
: - (PER) - - (SQA)
: 250 2 230V 400V. O 400 710 6 230V 400V.
930 - 16.668 m3/h
(mm) DIMENSIONS (mm)
PERFORMANCE CURVESKAM
Model
A B C D D1 D2 E F HT J K L MSingle phase Three phase Single
phaseThree phase
Single phase
Three phase/2 /4 /6 /2 /4 /6
250 315 260 220 250 261 290 10 10,5 0 - 10,5 0 - 126 126 33 53 12 73 73315 400 330 280 315 320 365 10 - 0 - - 0 - 149 149 41 68 12 82 82355 450 380 315 355 363 411 10 - 0 - - 0 - 156 156 41 75 12 82 82400 500 420 355 400 410 464 10 - 12 - - 0 - 200 176 92 78 12 122 97450 560 480 400 450 457 522 10 - 0 0 - 0 0 204 179 68 91 12 114 89500 630 560 450 500 512 572 10 - 13 0 - 13 0 201 176 60 97 12 104 79560 710 630 510 559 570 649 10 - 20 0 - 20 0 213 188 70 99 12 114 89630 800 710 580 630 640 730 12 - 25 25 - 25 7 207 182 60 103 12 104 79710 900 800 637 710 810 12 - - 11 - - 11 221 206 115 92 17 130 115
O ...14
VOLT
rpm
WATT
m3/h
mm
mm
TIMH
FB/4-250 230 1400 10 400250
350x350 80,00
FB/4-251 230 1400 50 1.200 350x350 140,00
FB/4-300 230 1400 50 1.700 300 400x400 146,00
FB/4-350 230 1400 120 3.200350
450x450 197,00
F/4-351 400 1400 145 3.600 450x450 210,00
F/4-400 230 1400 150 4.400400
500x500 226,00
F/4-401 400 1400 185 4.400 500x500 216,00
F/4-450 230 1400 370 5.600450
500x500 368,00
F/4-451 400 1400 370 5.600 500x500 343,00
F/4-500 230 1400 736 7.400500
550x550 413,00
F/4-501 400 1400 736 7.400 550x550 406,00
F/4-550 230 1400 736 10.500550
680x680 452,00
F/4-551 400 1400 736 10.500 680x680 426,00
F/4-600 230 1400 1.900 14.500
600
730x730 560,00
F/4-601 400 1400 1.900 14.500 730x730 550,00
FB/6-602 230 900 450 7.500 730x730 540,00
FT/6-603 400 900 515 7.500 730x730 480,00
A KAF
4 RMP. FB/4-602 6 RH.
230V 400V, 1400rpm ( FT/6-602 & KAFT/6-603, 900rpm).
M .
250mm 600mm.
M .
: , , , .
: REB-2,5 REB-5000W.
: (PER), , SQ.
PLATE MOUNTED AXIAL FLOW FANS
KAF =
= (400V/50Hz) = (230V/50Hz)
4 = 4 , 1400 rpm 6= 6 , 900 rpm
F B / 4-250
250 = mm (nominal diameter in mm)
400 - 14.500 m3/h
O ...
plate mounted axial flow fans
15
KINHH
A
rpm
kW / P
m3/h
ME mm dB(A)
Kg
TIMH
HIT- 24 1,3 920 0,37 0,50 18.300 610 64 41 648,00
HI- 36 . 1,25 1400 0,37 0,50 20.800 910 64 54 740,00
HI- 50 . 2,8 1400 1,10 1,50 43.170 1.270 64 89 960,00
IMANTOKINHTOI HI
=230V=400V
Type A B C
mm
inches
HIT - 24 760 760 450 610 24
HIT - 36 1000 1000 450 910 36
HIT - 50 1380 1380 450 1270 50
(mm)
13.500 - 40.700 m3/h
PLATE MOUNTED AXIAL BELT DRIVE FANS WITH AUTOMATIC LOUVRE SHUTTER
DIMENSIONS (mm)
380V/50Hz, , -24 . , -24 . IP: 55. F. . -430 , 1,2mm.
: 220V - , , ..
: , , , , ..
: M INVERTER 400V.
HIT-24 HIT-36 HIT-50
O ...16
10.000 - 130.000 m3/h
P:65
rpm
kW
MAX. ABS. CURRENT (A)
230V 400V
m3/h
BAg
CGT/4-560/-0,55 1415 0,55 2,6 1,5 9.800 80
CGT/4-560-5/-1,1 1400 1,1 4,7 2,7 13.787 83
CGT/4-560-5/-1,5 1405 1,5 6,6 3,8 14.857 85
CGT/4-630-5/-1,1 1400 1,1 4,7 2,7 16.323 90
CGT/4-630-5/-2,2 1410 2,2 9,5 5,5 20.892 111
CGT/4-630-5/-3 1410 3 13,0 7,5 21.626 116
CGT/4-710-7/-2,2 1410 2,2 9,5 5,5 22.247 128
CGT/4-710-7/-4 1415 4 - 9,5 28.711 138
CGT/4-710-7/-5,5 1430 5,5 - 12,5 32.713 161
CGT/4-800-3/-3 1410 3 13,0 7,5 32.013 136
CGT/4-800-3/-4 1415 4 - 9,5 34.922 141
CGT/4-800-3/-5,5 1430 5,5 - 12,5 36.376 164
CGT/4-800-6/-5,5 1430 5,5 - 12,5 38.734 167
CGT/4-800-6/-7,5 1440 7,5 - 16 40.175 175
CGT/4-900-3/-7,5 1440 7,5 - 16 49.059 213
CGT/4-900-6/-11 1450 11 - 23 55.846 238
CGT/4-900-6/-15 1450 15 - 31 61.132 255
CGT/4-1000-3/-11 1450 11 - 23 64.582 231
CGT/4-1000-3/-15 1450 15 - 31 65.874 248
CGT/4-1000-6/-18,5 1455 18,5 - 37 77.891 303
CGT/4-1000-9/-22 1460 22 - 42 82.071 322
CGT/4-1250-3/-15 1450 15 - 31 92.252 405
CGT/4-1250-3/-30 1460 30 - 58 116.778 565
CGT/4-1250-6/-37 1470 37 - 73 131.171 580
A CGT-CHGT
AXIAL CABINET FANSADJUSTABLE PITGH FANS
400V - 50HZ
3, 6 9 . 8 38 () .
IP: 55 F. . , 100.
: , . parking, .
: M INVERTER
: - 400oC / 300oC 200oC ( GHGT).- 2 ( CGT 2V).- M EX II26EExellT3 EX IIGEExdIIBT5 EExdllCT4.- 6 (900 rpm) 2 (2800 rpm)
O ... 17
axial flow fans
CGT (mm) DIMENSIONS CGT (mm)
M F400-120 F200-120
ISO-1940
3, 6, 7, 9 80 380
O ...18
HDT
rpmWATT
m3/h
ME mm
mm
dB(A) Kg
TIM
D/4-315 IIBT5 1330 120 2.240 315 400 x 400 56 9,5 1.153,00
HD/4-355 IIBT5 1340 180 3.120 355 450 x 450 60 11,0 1.274,00
HDT/4-400 IIBT5 1370 370 4.780 400 500 x 500 65 15,0 1.366,00
HD/4-450 IIBT5 1380 550 8.000 450 560 x 560 66 20,0 1.486,00
HD/4-560 IIBT5 1390 1100 13.700 560 710 x 710 73 29,0 1.910,00
400V/50z Directive. IP: 55. F. .
: , ,
, , , , .
: M INVERTER.
: (PER),
: 315, 355, 400 450 230V. O 355, 450 560 230V 6 . 450 560 400V 8 .
Type A B
C
D E F G
Number of poles
/4 /6 /8
HDT/315 400 330 323 - - 315 10 85 329
HDT/355 450 380 325 325 - 355 10 87 371
HDT/400 500 420 336 336 - 400 10 90 422
HDT/450 560 480 360 349 349 450 10 106 476
HDT/560 630 630 435 435 368 560 10 112 596
(mm)
FLAMEPROOF PLATE MOUNTED AXIAL FLOW FANS (Explosion Proof Type)
2.240 - 13.700 m3/h
O ... 19
axial flow fans
URBO
rpmmaximum
IWATT
maximum
m3/h
maximum
dB(A) ME . mm
(mm)
Kg
TIM
TURBO-351 N 1230 45 1.475 42 350 480 4 70,00
TURBO-451 N 1160 65 2.880 65 450 550 5,1 99,00
TURBO-451 CN 1160 65 2.880 65 450 1220/1650 10,4 99,00
TURBO-3000 1400 130 3.000 65 350 480 12 363,00
, . .- .- URBO - 351 / 451 N, TURBO 3000. .- URBO CN 1200/1480mm.- .- 230V/50Hz, .
TURBO , :
- A , ..
- .
- , .
750-3.000 m3/h
DESK FANS
.
Turbo 351 N /451 N
Turbo 451 CN Turbo 3000
TURBO 351/451 .
TURBO 351/451
TURBO 3000
O ...20
A mpresind.
H .
LITURBO .
30%.
.
220V 400V, IP:44 P:55.
: 680mm.
: 570mm.
30 dB
.
.
: , , , , , , ..
R MIXER
MOTE
W
rpm
m3/h
m2
MAXIMUM Y
m
Kg
TIM
2 LC-2000 . 150 700 7.500 200 8 16 788,00
2 55 LC-2000 . P:55 150 700 7.500 200 8 16 834,00
2 LC-2000 . 150 700 7.500 200 8 16 759,00
2 55 LC-2000 . P:55 150 700 7.500 200 8 16 807,00
3 LC-2002 . 220 700 10.000 300 18 18 842,00
3 55 LC-2002 . P:55 220 700 10.000 300 18 18 869,00
3 LC-2002 . 220 700 10.000 300 18 18 817,00
3 55 LC-2002 . P:55 220 700 10.000 300 18 18 846,00
ANEMI LITURBO
axial flow fans
O ...O ... 21
axial flow fans
DISTRIBUTION OF AIR STREAM
MAXIMUM A
LITURBO
TIM
QCR - 4V / 4M 220V 2 738,00
QCR - 4V / 10M 220V 6 922,00
QCR - 4V / 16M 220V 10 1.137,00
QCR - 4V / 2T 380V 2 990,00
QCR - 4V / 4T 380V 4 1.207,00
QCR - 4V / 6T 380V 6 1.540,00
QCR - 4V / 10T 380V 10 1.856,00
QCR - 4V / 16T 380V 16 2.317,00
H
O ...22
ANEMIE EI RTIC
E .
O .
O PRC 3 .
ARTIC-405 PRC . :
X : .
: 30 .
: 30 , 30 .
RTIC-405 PM 10-180 .
RTIC-405 PRC 1-8 .
ME TAXYTHTA
AEA m/s
W
m3/hME
mmdB(A) BA
KgTIMH
ARTIC-405 PM 3,8 50 4225/3403/2530 400 55 5 98,00
ARTIC-405 PRC 3,8 50 4225/3403/2530 400 55 5 124,00
ARTIC-405 P
ARTIC-405 PRC
: - .
, ..
........................................................................................................................................................................................
ANEMI O RTIC-R
TAXYTHTA
rpm
W
m3/hME
mmdB(A) BA
KgTIMH
ARTIC-400 R 1300/1100/900 60 1050/950/760 400 47 6 111,00
3
A .
360.
230V/50Hz.
M 3 .
2,30.
WALL MOUNTED AXIAL FANS
CEILING AXIAL FANS
O ... 23O ...23
cylindrical cased axial flow fans
23
TBT
PBB/PBT
cylindrical cased axial flow fans
26
24
27
28-29
30-31
38
36-37
COMPACT TCFB/TCFT TCBB/TCBT
TTT
TGT/THGT
TJFT-TJFU
VAP/VAPT
CDT
25
TCBBx2/TCBTx2
35TUB
34
32-33IFHT
A COMPACT
rpmMAX A.
WATT
m3/h
ME mm
dB(A) BAKg
TCFB/TTIM
TCBB/TTIM
TCFB/4-250/H 1330 60 1.215 250 52 5 348,00 420,00
TCFB/4-315/H 1300 100 2.350 315 54 7 359,00 481,00
TCFB/4-355/H 1225 200 3.490 355 58 8 424,00 596,00
TCFB/4-400/H 1200 340 5.070 400 60 9 447,00 656,00
TCFB/4-450/H 1290 480 6.760 450 65 13 548,00 712,00
TCFB/4-500/H 1290 650 9.200 500 68 16 585,00 809,00
TCFB/4-560/H 1250 980 12.480 560 71 22 818,00 TCFB/4-630/H 1200 1.700 17.060 630 72 25 945,00 TCBT/4-710/H 1450 3.400 25.500 710 76 54 - TCBT/4-800/H 1460 8.800 43.200 800 89 89 -
.
M IP:65 (230/400V-50HZ) F, -40C +70C.
O 2 710 800 IP: 55
.
PVC, TCBT/4-710, TCBT/4-800 .
: 230V /4-500 REB - 5000W REB 1R. 400V INVERTER.
: 2, 6 8 (2900,900,700 rpm), ( ), , Exll2G EExellT3 400 V.
2.340 - 43.200 m3/h
ype A B C 2 poles D E No. of holes N
250 327 292 170 254 10 4
315 386 355 170 320 315 10 8
355 426 395 170 320 355 10 8
400 487 450 170 400 12 8
450 537 500 180 450 12 8
500 595 560 180 500 12 12
560 655 620 240 560 12 12
630 725 690 240 630 12 12
710 (6 y 8 polos) 806 770 240 710 12 16
ype A B C D
E
4 poles 6 poles 8 poles
710/L (4polos) 806 770 350 710 405 - -
710/H (4polos) 806 770 350 710 426 - -
800/L 896 860 350 800 419 398 398
800/K 896 860 350 800 415 419 398
800/G 896 860 350 800 471 415 419
800/H 896 860 350 800 471 415 419
(mm)
TCFB =230VTCFT= 400V
P:65
CYLINDRICAL CASED AXIAL FLOW FANS(Plastic or Aluminium Impeller)
TCF= PVCTCB=
DIMENSINS (mm)
TCB
TCB TCF
O ...24
cylindrical cased axial flow fans
rpm
MAX A. WATT
m3/hME
mm dB(A) B
kgTIM
230V 400V 230V 400V
PBB/4-315/34 PBT/4-315/34 1300 100 150 2.250 315 54 13,5 456,00
PBB/4-400/34 PBT/4-400/34 1200 340 300 5.200 400 60 20 845,00
PBB/4-450/32 PBT/4-450/32 1290 480 500 6.700 450 65 26 1.072,00
PBB/4-560/32 PBT/4-560/32 1250 980 1210 12.300 560 71 39 1.120,00
PBB/4-630/32 PBT/4-630/32 1200 1.700 1.600 16.450 630 74 40 1.194,00
2.250 - 16.450 m3/h
ype A B C D E F
PBB or PBT/4-315 439 400 211 315 470 642
PBB or PBT/4-400 600 557 227 400 560 841
PBB or PBT/4-450 650 616 237 450 560 925
PBB or PBT/4-560 780 473 307 560 500 837
PBB or PBT/4-630 890 750 307 630 840 1149
(mm)
A PBB-PBT
PORTABLE COOLING FANS
P:65
M 230V/50z 400V/50Hz.
IP:65, F -40oC
+70oC.
g . .
2 .
PVC .
.
: :
- .
- .
- .
: 230V 4-630 REB - 5000W.
400V INVERTER.
PBB=230V
PBT=400V
DIMENSIONS (mm)
H .
O ... 25
rpmWATT
m3/h
M mm
dB(A) TIM
TBT/2-400 (1,5kW) 2800 1500 9.300 400 84 1.248,00
TBT/2-450 (3kW) 2800 3000 13.200 450 87 1.844,00
TBT/4-900 (3kW) 1400 3000 36.300 900 88 2.405,00
TBT/4-900 (5,5kW) 1440 5500 49.000 900 90 3.275,00
TBT
400V/50Hz
IP: 55 F.
( ).
.
.
: .
: M INVERTER
CYLINDRICAL CASED AXIAL FLOW FANS FOR HIGH PRESSURE APPLICATION
9.300 - 49.000 m3/h
PERFORMANCE CURVES
O ...26
GN
B
D
E
A C
HF
rpmWATT
m3/h
ME mm
dB(A) Bkg
TIM
TTT/4-450-H 1415 550 7.500 450 64 25 TTT/4-500-H 1415 750 10.800 500 67 38 TTT/4-560-H 1410 1100 14.000 560 68 35 TTT/4-630-H 1420 1500 17.350 630 70 50 TTT/4-710-H 1430 2200 23.700 710 75 64 TTT/4-800-H 1435 4000 32.000 800 84 82
TTT
400V . IP: 55, F,
. .
.
: +150C.
: INVERTER.7.500 - 32.000 m3/h
Type
A B C D E F G HNo. of
holes N
TTT/4-450 537 500 442 450 12 749 183 344 8
TTT/4-500 595 560 450 500 12 803 183 369 12
TTT/4-560 655 620 450 560 12 903 208 420 12
TTT/4-630 725 690 450 630 12 978 208 458 12
TTT/4-710 806 770 490 710 12 1085 228 519 16
TTT/4-800 896 860 490 800 12 1184 253 573 16
CYLINDRICAL CASED AXIAL BELT DRIVE FANS
(mm)
PERFORMANCE CURVES
O ... 27
cylindrical cased axial flow fans
METAB GT-THGT
400V - 50HZ
3, 6 9 . 8 38 () .
IP: 55 F. . , 100.
: , . parking, .
: M INVERTER
: - 400oC/2h ( THGT).- 2 ( TGT 2V).- EX II26EExellT3 EX IIGEExdIIBT5 EExdllCT4.- 2,4, 6 8 .- LC (Long Casing) .- : - TGT .
3.000 - 148.000 m3/h
CYLINDRICAL CASED AXIAL DJUSTABLE PITCH FANS
O ...28
LONG CASING
rpmME
mm MAX. POWER ABSORBED
(kW)
MAX. ABS. CURRENT (A)
230V 400V
m3/h
BAg
Short casing Long casing
TIM
TGT/4-560-5/-0,55 1415 560 0,55 2,4 1,4 10.551 49 66
TGT/4-560-5/-0,75 1415 560 0,75 3,3 1,9 11.926 50 67
TGT/4-560-5/-1,5 1420 560 1,5 5,5 3,2 14.857 56 73
TGT/4-630-5/-1,1 1410 630 1,1 4,2 2,4 16.323 57 72
TGT/4-630-5/-2,2 1430 630 2,2 8,3 4,8 20.892 65 80
TGT/4-630-5/-3 1430 630 3 11,3 6,5 21.626 68 83
TGT/4-710-7/2,2 1430 710 2,2 8,3 4,8 22.247 69 92
TGT/4-710-7/-3 1430 710 3 11,3 6,5 25.273 72 95
TGT/4-710-7/-5,5 1450 710 5,50 - 11,1 32.713 91 111
TGT/4-800-6/-4 1435 800 4 - 8,6 33.664 87 107
TGT/4-800-6/-5,5 1450 800 5,5 - 11,1 38.734 103 120
TGT/4-800-6/-7,5 1450 800 7,5 - 14,8 40.175 111 128
TGT/4-900-6/-7,5 1450 900 7,5 - 14,8 48.756 127 146
TGT/4-900-6/-11 1465 900 11 - 22,6 55.846 151 170
TGT/4-900-6/-15 1460 900 15 - 28,5 61.132 166 185
TGT/4-900-9/-15 1460 900 15 - 28,5 62.214 170 189
TGT/4-900-9/-18,5 1475 900 18,5 - 35 64.000 217 236
TGT/4-1000-6/-18,5 1475 1000 18,5 - 35 77.891 221 242
TGT/4-1000-9/-22 1475 1000 22 - 41 82.071 241 262
TGT/4-1250-3/-22 1475 1250 22 - 41 105.868 264 306
TGT/4-1250-3/-30 1480 1250 30 - 55 116.778 307 349
TGT/4-1250-9/-30 1480 1250 30 - 55 117.549 318 360
TGT/4-1250-9/-37 1485 1250 37 - 68 125.870 351 393
TGT/4-1250-9/-45 1485 1250 45 - 84 142.516 376 418
3, 6, 7, 9 80 380
Mo THGT 400OC/2h
TGT (mm)
O ... 29
DIMENSIONS TGT (mm)
cylindrical cased axial flow fans
A TJFT/TJFU
AXIAL JET FANS
-20oC +40oC. 400V , 50Hz, P: 55, F . . 2 . .
: parking, .
: - 2 2/4 .- 400oC/2h, F ( JHT).- .TJHT .TJFT .TJFU .
rpmThruST
(N)
m3/hIMPuLSION
(m/s)MOTOr
(kW)
MAXIMuM CurrENT
ABSOrBED (A)
SOuNDPrESSurE LEVEL
(dB(A) BAg
Form A*** Form B***
1 , 2
TJFT/2-315-CN 2790 24 4.500 16 0,75 1,6 71 64 57
TJFT/2-355-CN 2810 40 6.500 18 1,1 2,3 74 67 76
TJFT/2-400-CN 2870 60 9.000 20 1,5 4,2 79 71 89
TJFT/2-450-C 2840 85 12.100 21 2,2 4,5 82 74 133
TJFT/2-500-C 2890 144 17.500 25 4 7,5 85 78 165
TJFT/2-560-C 2925 235 25.000 28 7,5 13,6 88 81 220
TJFT/2-630-C 2945 387 36.100 33 15 27 90 83 290
2 , 2/4
TJFT/2/4-315-CN 2820/1400 24 4.500 16 0,8/0,2 1,9/0,6 71/56 64/49 57
TJFT/2/4-355-CN 2810/1390 40 6.500 18 1,1/0,25 2,4/0,75 74/59 67/52 76
TJFT/2/4-400-CN 2900/1435 60 9.000 20 1,5/0,37 4,2/1,3 79/64 71/56 89
TJFT/2/4-450-C 2845/1420 85 12.100 21 2,2/0,5 4,6/1,5 82/67 74/59 134
TJFT/2/4-500-C 2890/1440 144 17.500 25 4,4/1,1 8,6/2,8 85/70 78/63 166
TJFT/2/4-560-C 2930/1470 235 25.000 28 8/2 15,3/4,8 88/73 81/66 223
TJFT/2/4-630-C 2950/1470 387 36.100 33 16/4 30,5/9,6 90/75 83/68 311
1 , 2 - F-400 - 120
TJFu/2-315-C 2790 25 4.600 16 0,75 1,6 - 62 56
TJFu/2-355-C 2810 43 6.800 19 1,1 2,3 - 66 75
TJFu/2-400-C 2870 68 9.700 21 1,5 3 - 70 88
2 , 2/4 - F400 - 120
TJFu/2/4-315-C 2820/1400 25 4.600 16 0,8/0,2 1,9/0,6 - 62/46 56
TJFu/2/4-355-C 2810/1390 43 6.800 19 1,1/0,25 2,4/0,75 - 66/49 75
TJFu/2/4-400-C 2900/1435 68 9.700 21 1,5/0,37 3,5/1,3 - 70/55 88
O ...30
2 TJHT
TJFT (mm) DIMENSIONS TJFT (mm)
ACCESSORIES
O ... 31
axial jet fans
Car parking
TJFU (mm) DIMENSIONS TJFU (mm)
O ...32
IFHT
CENTRIFUGAL JET FANS
.
, .
380-420V/50z, IP:55, H.
O 12101-3
( 0370-CPD-1085) F300/120, 300oC 120 F400/120 400oC 120 .
2 4/8 (Dalhander winding)
SO:1940-1,G6.3
M . L10 20.000 .
: , .
, .
: - P:65 .- RAL
rpm
m3/hIXY
KW
MAX. EN* /
AdB(A) B
kgTIM
IFHT/4/8-50N-C 1420/710 50/13 5.800/2.880 1,1/0,18 3/1,1 15/4,5 75/59 76
IFHT/4/8-75N-C 1420/710 75/19 8.100/4.050 2,2/0,37 5,4/1,9 30/7,5 77/61 120
IFHT/4/8-100N-C 1420/710 95/24 8.900/4.450 2,2/0,37 5,4/1,9 30/7,5 78/63 120
* 2
nlet guard Low profile External terminal box Optional electrical isolator
ir protection quard at the inlet side
Useful in low parkings Easy connection Fitted to fan for security (optional)
O ... 33
centrifugal jet fans
Model A B E H I J K L N
IFHT 50 600 275 800 272 844 890 1232 1298 3
IFHT 75 800 250 1000 337 1044 1090 1600 1666 4
IFHT 100 800 250 1000 337 1044 1090 1600 1666 4
IFHT (mm) DIMENSIONS IFHT (mm)
CFD
A TCBBx2
rpm230V 400V
IXYKW
230V 400V
m3/h
A
230V 400VdB(A) B
kgTIM
TCBBx2/4-450 1370 1400 1,24 1,25 6.900 5,40 3,40 75 42 TCBBx2/4-500 1300 1340 1,70 1,75 9.400 7,30 3,60 76 50 TCBBx2/4-560 1340 1360 3,25 3,12 14.300 15,50 5,80 78 66 TCBBx2/4-630 1280 1370 3,90 4,20 18.200 19,00 8,00 79 80
230V 400V. 2 ,
. ( ) terminal box. IP:65 K F -40oC +70oC. .
E: , .
: 450 500 .
Type A B C D ENo. of
holes N
450 537 375 500 450 12 8
500 595 375 550 500 12 12
560 655 520 620 560 12 12
630 725 520 660 630 12 12
(mm)
TCBB 230V, 50Hz TCBT 400V, 50Hz.
IP:65
CONTRAROTATING CASE AXIAL FANS(for very high pressure)
TCBBx2 E TCBBx2
Flexible connector
Duct Matching flange
Mounting feet
Wire guard Wire guard Flexible connector
Matching flange
Duct
6.900 - 18.200 m3/h
O ...34
A E TUB
M 230V/50Hz, IP:44, . . 6 RH.
: .
H: REB - 5000W.
: (UB). . 350mm 630mm. .
CYLINDRICAL CASED AXIAL FLOW FANS
rpm
W
ME mm
ME
mm
m3/h
TIM
TUB/4 - 350/018 1400 150 400 350 4.000 190,00
TUB/4 - 400/018 1400 150 450 400 5.700 214,00
TUB/4 - 450/050 1400 370 500 450 8.000 288,00
TUB/4 - 500/100 1400 740 550 500 11.000 325,00
TUB/4 - 550/100 1400 740 600 550 15.000 355,00
4.000 - 15.000 m3/h
RH IMPELLER SERIES RH
O ... 35
cylindrical cased axial flow fans
ISI 304
O ...36
A TCDT
M 400V/50z.
IP:55, .
85oC 100% RH.
E: , ..
:
- TCDT/4-900 4 5,5 7,5kw.
- Mo 135oC 150oC.
- .
- PTC.
- Mo FF1.
- Mo TCDH EXD
A P P L I C A T I O N S
Industrialdryers
Wooddryers
85CCONTINUOUSOPERATION
rpmIXY
KW
MAXIMUMA
400V(A)
MAXIMUM m3/h B
kgTIM
Uniderectional
impellerReversible impeller
TCDT/4-560 1,1KW 1430 1,1 2,5 11.200 9.200 30
TCDT/4-560 1,5KW 1430 1,5 3,4 12.800 10.500 32
TCDT/4-630 1,1KW 1430 1,1 2,5 13.600 12.700 34
TCDT/4-630 1,5KW 1430 1,5 3,4 16.200 14.700 35
TCDT/4-630 2,2KW 1440 2,2 4,8 18.400 16.400 39
TCDT/4-630 3KW 1440 3 6,5 20.000 17.300 42
TCDT/4-710 1,1KW 1430 1,1 2,5 17.000 14.500 35
TCDT/4-710 1,5KW 1430 1,5 3,4 19.900 17.700 37
TCDT/4-710 2,2KW 1440 2,2 4,8 22.000 20.500 41
TCDT/4-710 3KW 1440 3 6,5 25.500 22.900 44
TCDT/4-800 2,2KW 1440 2,2 4,8 28.900 23.800 47
TCDT/4-800 3KW 1440 3 6,5 33.800 28.700 50
TCDT/4-800 4KW 1440 4 8,3 36.500 30.700 56
TCDT/4-900 3KW 1440 3 6,5 33.000 31.000 52
AXIAL FLOW FANS FOR WOOD DRYERS
O ... 37
TCDT APPLICATIONS TCDT
Model A B C D E F d1 d2 d3 d4
TCDT/4-560 1,1KW 296 146 150 2,5 25 12 560 620 655 570
TCDT/4-560 1,5KW 296 146 150 2,5 25 12 560 620 655 570
TCDT/4-630 1,1kW 296 146 150 2,5 25 12 690 725 650 630
TCDT/4-630 1,5kW 296 146 150 2,5 25 12 690 725 650 630
TCDT/4-630 2,2kW 342 192 150 2,5 25 12 690 725 650 630
TCDT/4-630 3kW 342 192 150 2,5 25 12 690 725 650 630
TCDT/4-710 1,1kW 296 146 150 2,5 25 12 770 806 730 710
TCDT/4-710 1,5kW 296 146 150 2,5 25 12 770 806 730 710
TCDT/4-710 2,2kW 342 192 150 2,5 25 12 770 806 730 710
TCDT/4-710 3kW 342 192 150 2,5 25 12 770 806 730 710
TCDT/4-800 2,2kW 342 192 150 2,5 25 12 860 896 820 800
TCDT/4-800 3kW 342 192 150 2,5 25 12 860 896 820 800
TCDT/4-800 4kW 360 210 150 2,5 25 12 860 896 820 800
TCDT/4-900 3KW 342 192 150 2,5 25 12 900 970 1006 915
TCDT/4-900 4kW 360 210 150 2,5 25 12 900 970 1006 915
IA TCDT(mm) DIMENSIONS TCDT(mm)
axial flow fans for wood dryers
O ...38
A BA VAP
rpm50Hz 60Hz
HP m3/h
M mm
TIM
VAPB/2-300/150 3000 3500 1,5 3.500 300 498,00
VAP/2-300/150 3000 3500 1,5 3.500 300 490,00
VAPB/2-350/200 3000 3500 2 6.000 350 598,00
VAPT/2-350/200 3000 3500 2 6.000 350 590,00
VAPB/2-400/300 3000 3500 3 8.500 400 810,00
VAPT/2-400/300 3000 3500 3 8.500 400 800,00
VAPT/2-450/400 3000 3500 4 12.800 450 910,00
VAPT/2-500/550 3000 3500 5,5 15.500 500 1.100,00
M 230V 400V.
.
.
6 F6.
.
: x .
: INVERTER 400V.
: 440V - 60Hz, 2800 rpm .- M .
- .
VAPB =230V VAPT =400V
3.500 - 15.500 m3/h
HEAVY DUTY CYLINDRICAL CASED AXIAL FANS
O ... 39O ... 39
o
roof mounted fans
48
40-41
MAX-TEMP CTVB/CTVT
MIXVENT-TH
44CRHB/CRHT
HCTB/HCTT 42-43
CTVB HP
FKTZ
49
50
45
46-47
TCDH
MAX-TEMP CTHB/CTHT
O ...40
1 or
3
6
54 or
2
VENT - TH
rpmHS LS
WATT
HS LS
m3/h
HS LSdB(A)
ME mm
mm
Bkg
TIM
TH-500/150 2450 - 1800 68 - 40 470 - 355 49 - 45 150 300 x 300 3,8 340,00
TH-800/200 2500 - 2100 140 - 118 790 - 630 53 - 52 200 300 x 300 5,6 406,00
TH-1300/250 2400 - 1800 170 - 120 1.100 - 780 59 - 58 250 435 x 435 11,2 690,00
TH-2000/315 2480 - 1750 255 - 160 1.725 - 1.200 67 - 63 315 560 x 560 17,2 768,00
2 230V, IP: 44. 60oC. B. . PVC 500 & 800 1300 & 2000.
: .
. ( )
.
H: 2 COM-2 REB 5000W
2 .
: (MCA), , - (StripSteel), (Clips for Band). 355 - 1.725 m3/h
HS= LS=
Type A B C D E F G H I
TH-500/150 400 349 300 150 245 10 20 274 33
TH-500/160 400 349 300 160 245 10 20 274 33
TH-800 N 400 371 300 198 245 10 20 306 36
TH-800 400 371 300 198 245 10 20 306 36
TH-1300 546 457 435 248 330 12 20 372 42
TH-2000 735 544 560 312 450 12 20 450 50
ROOF MOUNTED MIXED FLOW FANS
(mm)
O ... 41
Type A B C E G
JBS-300 470 289 245 300 380
JBS-435 600 419 330 300 510
JBS-560 725 544 450 300 635
Type A B C E F
JMS-300 470 290 245 50 70
JMS-435 600 420 330 50 70
JMS-560 725 545 450 50 70
1 or
3
6
54 or
2
Type1
Sealingframe
2Flat roofUpstand
3Black draft
shutter
4Flexibleducting
5Fl. acoustic
ducting
6Worm
drive clips
TH-500/150 JMS-300 JBS-300 CAR-150 GSA-150 GSI-160 CX-215
TH-500/160 JMS-300 JBS-300 CAR-160 GSA-160 GSI-160 CX-215
TH-800 N JMS-300 JBS-300 CAR-200 GSA-200 GSI-200 CX-250
TH-800 JMS-300 JBS-300 CAR-200 GSA-200 GSI-200 CX-250
TH-1300 JMS-435 JBS-435 CAR-250 GSA-250 GSI-250 CX-315
TH-2000 JMS-560 JBS-560 CAR-315 GSA-315 GSI-315 CX-315
Flat Roof Upstands JBS
Sealing Frame JMS
EH E TH MOUNTING ACCESSORIES TH
TH PERFORMANCE CURVES TH
O ...42
D
F
G
HB C
A
E
rpmWATT
m3/h
dB(A)M
mm
M.
mm
H
mm
Bkg
TIM
HCTB HCTT230V 400V
HCTB/4-315-B 1300 100 1.930 58 315 640 560 x 560 14,4 635,00 644,00
HCTB/4-355-B 1225 200 2.680 55 355 760 630 x 630 15,8 719,00 700,00
HCTB/4-400-B 1290 340 3.700 58 400 760 630 x 630 16,5 735,00 721,00
HCTB/4-450-B 1290 480 5.600 61 450 895 710 x 710 23,5 874,00 858,00
HCTB/4-500-B 1290 650 7.100 67 500 895 710 x 710 25,4 895,00 880,00
HCTB/4-560-B 1200 980 9.820 69 560 1150 905 x 905 40 1.132,00 1.305,00
HCTB/4-630-B 1290 1.700 13.000 70 630 1150 905 x 905 42,6 1.390,00 1.351,00
HCTT/4-710-B 1300 2.200 18.400 80 710 1350 1100 x 1100 60 - 1.610,00
HCTT/4-800-B 1400 3.000 23.800 89 800 1350 1100 x 1100 67 - 2.722,00
HCTT/4-900-B 1400 4.000 30.000 92 900 1580 1250 x 1250 77 - 3.733,00
HCTT/4-1000-B 1450 5.500 38.500 93 1000 1580 1250 x 1250 123 - 4.051,00
HCTB - HCTT
230V 400V. A . IP: 65. F ( -40OC +70OC).
.
: A . , , ..
H: 230V HCTB/4-500 REB - 5000W. 400V INVERTER. 1.930 - 38.000 m3/h
ype A B C D E F G H
315 640 560 450 315 12 40 70 341
355 760 630 535 355 12 40 80 361
400 760 630 535 400 12 40 80 361
450 895 710 590 450 14 40 110 410
500 895 710 590 500 14 40 110 410
560 1150 905 750 560 14 50 165 488
630 1150 905 750 630 14 50 165 488
710 1350 1100 840 710 14 50 200 551
800 1350 1100 840 800 14 50 200 732
900 1580 1250 950 900 14 50 200 756
1000 1580 1250 950 1000 14 50 200 756
(mm)
CTB HCTT T .
ROOF MOUNTED AXIAL FLOW FANS
: 6 8 . - ().
O ... 43
HCTB PERFORMANCE CURVES HCTB
O ...44
CRHB-CRHT
230V/50Hz 400V/50Hz . . IP: 54, F . /FF. o .
: , , ..
: 2 .
ROOF MOUNTED FANSHORIZONTAL DISCHARGE
CRHB = 230V/50Hz CRHT= 400V/50Hz
M A
/OFF
SUPPLY/VOLTAGE
V-HZ
M mm
rpm
MAXIMUM
W
MAXIMUMA
A
m3/h
dB(A)
MAXI-MUM
.C
BAKg
TIM
220V 380V
CRHB/2-225 230-50/60 225 2450 140 0,63 1.100 58 64 50 7
CRHB/2-250 230-50/60 250 2450 140 0,63 1.150 58 64 70 7,5
CRHB/4-225 230-50/60 225 1450 50 0,25 670 48 54 60 7
CRHB/4-250 230-50/60 250 1450 50 0,25 795 51 54 70 7,5
CRHB/2-280 230-50/60 280 1400 85 0,40 1.300 47 53 50 8
CRHB/4-315 230-50/60 315 1400 140 0,60 1.844 58 61 70 17
CRHB/4-355 230-50 355 1370 230 0,85 3.000 63 64 70 21
CRHB/4-400 230-50/60 400 1400 410 2,00 4.205 64 67 60 22
CRHB/4-500 230-50 500 1400 1200 5,20 8.300 71 76 70 44
CRHB/6-315 230-50 315 980 69 0,40 1.200 48 52 70 17
CRHB/6-355 230-50 355 955 87 0,44 1.960 58 58 70 21
CRHB/6-400 230-50/60 400 935 153 0,70 2.637 58 58 60 22
CRHB/6-500 230-50 500 890 345 1,50 4.958 58 63 70 27
CRHB/6-560 230-50 560 895 640 2,75 7.170 59 64 70 30
CRHB/6-630 230-50 630 905 1090 4,90 9.800 59 64 50 50
CRHB/8-500 230-50 500 690 270 1,30 4.000 51 56 60 27
CRHB/8-560 230-50 560 650 360 1,64 5.250 51 55 60 30
CRHB/8-630 230-50 630 670 465 2,16 7.190 53 58 70 50
1.100 - 9.800 m3/h
O ... 45
TY rpm
kWAMBER
(A)
m3/h
dB(A B(Kg)
TIM
Inlet Outlet
TCDH-Exd-010-4 1500 0,25 0,77 1.120 58 62 22
TCDH-Exd-020-4 1500 0,25 0,77 2.450 62 66 25
TCDH-Exd-030-4 1500 0,37 1,1 3.300 67 71 28
TCDH-Exd-040-4 1500 0,55 1,6 5.500 71 75 35
TCDH-Exd-060-4 1500 0,75 2 7.000 74 78 57
TCDH-Exd-080-4 1500 1,5 3,6 9.600 76 81 68
TCDH-Exd-105-4 1500 2,2 5,1 12.800 79 84 90
TCDH-Exd-020-6 1000 1,18 1,1 1.650 52 56 25
TCDH-Exd-030-6 1000 1,18 1,1 2.200 57 61 32
TCDH-Exd-040-6 1000 0,26 1,2 3.700 61 65 35
TCDH-Exd-060-6 1000 0,26 1,2 4.700 64 68 57
TCDH-Exd-080-6 1000 0,37 1,6 6.500 66 71 68
TCDH-Exd-105-6 1000 0,75 2,2 8.700 68 73 90
TCDH-Exd-110-6 1000 1,1 3,2 11.000 72 77 96
TCDH-Exd-140-6 1000 2,2 5,5 16.000 75 81 110
TCDH-Exd-195-6 1000 3 8,5 22.500 78 83 126
TCDH-Exd-250-6 1000 5,5 12 25.500 81 86 150
ANTI TCDH EXD
ROOF MOUNTED FANSFLAME PROOF
1.120 - 25.500 m3/h
. +40C. 155C .
: , , , ..
230V/400V - 50Hz, 4,6 8 P:55, F A Directive T 2G EExd IIBT4
O ...46
4 Drills
D
E
C
AH
BH
F
rpm WATT
m3/h
dB(A)M
mm
M.
mm
H mm
Bkg
TIM
CTHB CTHT220V 380V
CTHB/4-140 1370 60 800 46 180 415 300 x 300 7.5 518,00 457,00
CTHB/4-180 1330 70 990 46 180 415 300 x 300 8 561,00 537,00
CTHB/4-200 1320 120 1.450 49 250 561 435 x 435 14 657,00 633,00
CTHB/4-225 1350 170 2.100 53 250 561 435 x 435 17 770,00 718,00
CTHB/4-250 1320 280 3.100 57 355 762 560 x 560 28 882,00 808,00
CTHB/4-315 1375 590 4.900 60 355 762 560 x 560 32 1.033,00 991,00
CTHB/4-400 1380 1.100 7.000 67 400 850 630 x 630 42 1.265,00 1.178,00
CTHT/4-450 1440 2.300 10.200 71 500 962 710 x 710 67 - 1.631,00
CTHT/6-500 965 1.400 10.500 63 630 1214 905 x 905 104 - 2.310,00
CTHT/6-560 950 2.400 16.000 66 630 1214 905 x 905 118 - 2.434,00
CTHT/6-630 950 3.700 21.000 70 710 1336 1100 x 1100 156 - 2.831,00
400oC/2h CTHB
230V/50Hz 400V-50Hz. .
.
. 400oC 2 . IP: 55. -K F. T 140, 180 200 200C ,
: , . , .
H: 230V REB - 5000W 400V INVERTER
: 4, 6 8 2 .
800 - 21.000 m3/h
ype A BH C D* E F
140 415 277 300 180 245 10
180 415 292 300 180 245 10
200 561 340 435 250 330 12
225 561 383 435 250 330 12
250 762 425 560 355 450 12
315 762 469 560 355 450 12
400 850 532 630 400 535 12
450 962 713 710 500 590 14
500 1214 824 905 630 750 14
560 1214 874 905 630 750 14
630 1336 1029 1100 710 840 14
(mm)
ROOF MOUNTED CENTRIFUGAL 400oC/2h RATED FANS
*
CTHB = 230V CTHT= 400V
SMOKEFANS
200CCONTINUOUSOPERATION
Type of fan1
Sealingframe
2Flat roof insulate
up-stand
3Acoustic up-stand
4Accessor and adapter plate
5Back draft
shutter
6Flange with
spigot
7Flexiblecouping
8Circularadapter
140180
JMS-300 JBS-300 JAA-300 JPA-300 JCA-300 JBR-300 JAE-300 JCC-300
200225
JMS-435 JBS-435 JAA-435 JPA-435 JCA-435 JBR-435 JAE-435 JCC-435
250315
JMS-560 JBS-560 JAA-560 JPA-560 JCA-560 JBR-560 JAE-560 JCC-560
400 JMS-630 JBS-630 JAA-630 JPA-630 JCA-630 JBR-630 JAE-630 JCC-630450 JMS-710 JBS-710 JAA-710 JPA-710 JCA-710 JBR-710 JAE-710 -500560
JMS-905 JBS-905 JAA-905 JPA-905 JCA-905 JBR-905 JAE-905 -
630 JMS-1100 JBS-1100 JAA-1100 JPA-1100 JCA-1100 JBR-1100 JAE-1100 -
KAM CTHB/T PERFORMANCE CURVES CTHB/T
JMS JBS JCA JPAJBR JAE JCC
6
CTHB-CTVB UNTING ACCESSORIES CTHB - CTVB
47O ...
O ...48
230V 400V .
400oC 2 . T 140, 180 200 120C .
: , .
H: 230V REB-5000W 400V INVERTER.
4,6, 8, .
E 400o C/2h CTVB
ROOF MOUNTED CENTRIFUGAL 400oC/2h)
CTVB = 230V CTVT = 400V
(mm)
750 - 19.500 m3/h
rpm WATT
m3/h
M.
mm M
mm
H
mm
dB(A)
TIM
CTVB CTVT
220V 380V
CTVB/4-140 1375 60 725 180 421 300 x 300 46 621,00 582,00
CTVB/4-180 1330 60 830 180 421 300 x 300 46 699,00 655,00
CTVB/4-200 1330 100 1.200 250 556 435 x 435 49 766,00 740,00
CTVB/4-225 1350 130 1.900 250 556 435 x 435 53 867,00 861,00
CTVB/4-250 1325 250 2.800 355 750 560 x 560 56 1.027,00 943,00
CTVB/4-315 1390 570 4.200 355 750 560 x 560 60 1.168,00 1.062,00
CTVB/4-400 1390 1.100 6.250 400 850 630 x 630 67 1.404,00 1.291,00
CTV/6-450 950 800 6.300 500 950 710 x 710 59 - 2.176,00
CTV/6-500 975 1.500 10.000 630 1216 905 x 905 62 - 2.536,00
CTV/6-560 950 2.400 15.000 630 1216 905 x 905 66 - 2.802,00
CTV/6-630 950 3.900 19.500 710 1327 1100 x 1100 70 - 3.207,00
ype AV BV C D* E F
140 421 359 300 180 245 10
180 421 374 300 180 245 10
200 556 404 435 250 330 12
225 556 452 435 250 330 12
250 750 522 560 355 450 12
315 750 564 560 355 450 12
400 850 608 630 400 535 12
450 950 741 710 500 590 14
500 1216 832 905 630 750 14
560 1216 832 905 630 750 14
630 1327 1053 1100 710 840 14
.
SMOKEFANS
O ... 49
E 400o C/2h CTVB HP
ROOF MOUNTED CENTRIFUGAL 400oC/2h)
SMOKEFANS
400-50Hz, 4 . IP: 55, F PTC. 400oC 2 . 120oC .
H ( ) . -FF .
H: INVERTER.
: S
.
4/8, 4/6 .
rpm
MAXIMUMA.
watt
MAXIMUMA.
E400V (a)
MAXIMUM
m3/h
dB(a)
B(Kg)
TIM
Standard verSion
CTVT/4-632 5,5KW 1465 6,10 10,9 18000 83 177
CTVT/4-631 7,5KW 1480 6,67 12,4 20700 85 180
CTVT/4-712 11KW 1470 12,25 21,3 26000 90 267
CTVT/4-711 15KW 1480 16,39 29,5 32500 90 303
CTVT/4-802 18,5KW 1480 19,85 34,5 35400 91 361
CTVT/4-801 22KW 1485 26,00 43,6 44500 94 376
acouStic verSion (inS)
CTVT/4-632 5,5KW INS 1465 6,10 10,9 18000 70 221
CTVT/4-631 7,5KW INS 1480 6,67 12,4 20700 77 224
CTVT/4-712 11KW INS 1470 12,25 21,3 26000 82 357
CTVT/4-711 15KW INS 1480 16,39 29,5 32500 83 393
CTVT/4-802 18,5KW INS 1480 19,85 34,5 35400 83 492
CTVT/4-801 22KW INS 1485 26,00 43,6 44500 87 507
(mm) DIMENSIONS (mm)
O ...50
A TZAKI FKTZ
A 200C CTHB 200C
230V/50Hz, 1400rpm. IP: 54. K F. o. . .
.
E: . .
H : REB - 5000W.
rpmWATT
m3/h
Pa
ME mm
mm
TIM
FKTZ/4-200/012 1400 120 950 180 200 350 x 350 274,00
FKTZ/4-200/025 1400 250 1.150 250 200 350x350 298,00
ROOF MOUNTED FANS FOR FIREPLACES
ROOF MOUNTED FANS 200C CONTINUOUS FOR FIREPLACES
: 400C/2h 200C/2h .
O
850-1.100 m3/h
........................................................................................................................................................................................
200CCONTINUOUSOPERATION
230V/50Hz .
.
200C
IP: 54. K F.
E: , .
H : REB - 5000W.
rpm WATT
m3/h
dB(A)M
mm
M.
mm
H mm
Bkg
TIM
220V 380V
CTHB/4-140 1370 60 800 46 180 415 300 x 300 7.5 518,00
CTHB/4-180 1330 70 990 46 180 415 300 x 300 8 561,00
CTHB/4-200 1320 120 1.450 49 250 561 435 x 435 14 657,00
51O ...51
centrifugal fans
52-57
58-61
62-65
66-69
70-73
74-79
80-83
84-87
88-89
90-91
92-93
94-95
96-99
100-102
CBM-FAN SECTION
FRF-FRB-KOS-VCE-CAF
FKS - FKSG - BLOWER - CBT
FKK-FKKI - RK
CAB -THERMOBOX - CHEMINAIR
CVAB - CHVB - CVHT
CBTR - FKY -
CKAT-CRFT-CKFT-CRGT-CRIT-CIB-CIT
CMAB-CHAT-CFHT-CFMT
SEAT
CBP- FDA
CBS - FSA
BDB-BSB
ADA
O ...52
- CBM
1.300 - 7.400 m3/h
= IP: 44, F /4= 4 (1400 rpm), /6= 6 (900 rpm) 10 =E . ,
. , mm WG
( )
230V/50Hz
. Mo IP: 20, F. Mo IP: 44, F .
: , , ..
H: REB - 5000W.
SILENT-BLOCK
INC
HE
S
MOTER
m3/h
. F/Smm
( x x )
TIM
HP W
180/1
80 CBM/6 - 7/7 1/10 72 1.395475 x 475 x 475
197,00 331,00
CBM/4 - 7/7 1/5 147 1.565 197,00 331,00
240/
180 CBM/6 - 9/7 1/6 122 2.170
575 x 575 x 575
212,00 363,00
CBM/6 - 9/7 1/3 245 2.8606 212,00 363,00
CBM/6 - 9/7 T 1/3 245 2.6002 225,00 376,00
240/
240 CBM/6 - 9/9 1/3 245 2.900
575 x 575 x 575
221,00 372,00
CBM/6 - 9/9 T 1/3 245 2.9002 247,00 398,00
CBM/4 - 9/9 1/2 373 2.65025 221,00 372,00
270/2
00 CBM/6 - 10/8 1/2 373 4.100575 x 575 x 575
260,00 413,00
CBM/4 - 10/8 1/2 373 3.28030 260,00 413,00
270/
270
CBM/6 -10/10 1/2 373 4.700
575 x 575 x 575
269,00 425,00
CBM/6 - 10/10 T 1/2 373 4.7003 280,00 436,00
CBM/6 - 10/10 3/4 550 4.950 269,00 425,00
CBM/4 - 10/10 1/2 373 2.70033 269,00 425,00
CBM/4 - 10/10 3/4 550 3.30030 269,00 425,00
320/2
40 CBM/6 - 12/9 3/4 550 4.70024675 x 675 x 675
373,00 559,00
CBM/6 - 12/9 T 1 736 5.60018 434,00 620,00
320/
320
CBM/6 - 12/12 3/4 550 4.74017
675 x 675 x 675
388,00 578,00
CBM/6 - 12/12 T 3/4 550 5.25017 448,00 638,00
CBM/6 - 12/12 T 1 736 6.10017 459,00 649,00
CBM/6 - 12/12 1,5 1.100 7.420 558,00 748,00
( )
FAN SECTION
DOUBLE INLET DIRECT DRIVE FANS(for low pressure)
K
centrifugal fans
= IP: 44, B
10 = . , .
, mm WG ( )
230V/50Hz,
-400V/50z
: REB 3 .
: INVERTER.
T CBM-3V
DOUBLE INLET DIRECT DRIVE FANS THREE SPEED OPERATION
400V CBM-TRI
INVERTER
INC
HE
S
MOTE
m3/hMIK
. F/Smm
TIM
HP W
180/180 CBM/4-7/7 3V 1/5 147 700 1.100 1.565 475 x 475 x 475 215,00 348,00
240/240CBM/6-9/9 3V 1/3 245 2.100 2.450 2.980
575 x 575 x 575255,00 403,00
CBM/4-9/9 3V 1/2 373 1.3007 1.70014 2.80022 255,00 403,00
270/200CBM/6-10/8 3V 1/2 373 2.2004 2.7006 4.000
575 x 575 x 575271,00 421,00
CBM/4-10/8 3V 1/2 373 1.90020 2.40025 3.15028 271,00 421,00
270/270CBM/6-10/10 3V 1/2 373 2.7005 3.4007 4.500 575 x 575 x 575 290,00 440,00
CBM/4-10/10 3V 3/4 550 2.90020 3.30025 3.50028 575 x 575 x 575 303,00 459,00
320/320 CBM/6-12/12 3V 3/4 550 3.0003 3.7006 5.10011 675 x 675 x 675 426,00 617,00
( )
ENTO FAN SECTION
DOUBLE INLET DIRECT DRIVE FANS THREE PHASE MOTOR
( )
ENTO FAN SECTIONI
NC
HE
S
m3/h. F/S
mm
TIM
HP W
CBM/6-12/9 TRI 1,5 1100 6.3005 675 x 675 x 675 378,00 564,00
CBM/6-12/12 BT TRI 1,5 1100 7.4206 675 x 675 x 675 394,00 587,00
CBM/6-15/15 T TRI 3 2200 8.95034 800 x 800 x 800 894,00 1.111,00
320/240
320/320
380/380
/4= 4 (1400 rpm). X 6 (900 rpm). 10 =E . , . , mm WG ( ).
53O ...
O ...
- CBM-RE
EXTERNAL ROTOR CENTRIFUGAL FANS
230V/50Hz ( ) 4 6 7/7 :44, F 9/7 12/12 :55, F -20oC +40oC
W
rpm
m3/h
. F/Smm
( x x )
TIMH
( )
TIMH
FAN SECTION
180/
180
CBM-RE-7/7 4P-147W-IP:44 147 1400 1.650 50x50x50 347,00 503,00
CBM-RE-7/7 4P-184W-IP:44 184 1400 1.970 50x50x50 355,00 511,00
CBM-RE-7/7 4P-250W-IP:44 250 1400 2.320 50x50x50 394,00 550,00
CBM-RE-7/7 4P-300W-IP:44 300 1400 2.310 50x50x50 366,00 522,00
240/
180 CBM-RE-9/7 4P-300W-IP:55 300 1400 2.250 60x60x60 451,00 636,00
CBM-RE-9/7 4P-420W-IP:55 420 1400 2.520 60x60x60 495,00 680,00
240/
240
CBM-RE-9/9 4P-300W-IP:55 300 1400 2.490 60x60x60 489,00 674,00
CBM-RE-9/9 4P-420W-IP:55 420 1400 2.700 60x60x60 484,00 669,00
CBM-RE-9/9 4P-550W-IP:55 550 1400 3.490 60x60x60 517,00 702,00
CBM-RE-9/9 4P-600W-IP:55 600 1400 3.800 60x60x60 544,00 729,00
270/
200
CBM-RE-10/8 6P-245W-IP:55 245 900 3.000 60x60x60 537,00 725,00
CBM-RE-10/8 4P-550W-IP:55 550 1400 2.900 60x60x60 542,00 730,00
CBM-RE-10/8 4P-600W-IP:55 600 1400 3.100 60x60x60 567,00 755,00
270/
270
CBM-RE-10/10 6P-245W-IP:55 245 900 3.400 60x60x60 542,00 730,00
CBM-RE-10/10 6P-515W-IP:55 515 900 4.500 60x60x60 560,00 748,00
CBM-RE-10/10 4P-550W-IP:55 550 1400 3.200 60x60x60 554,00 742,00
CBM-RE-10/10 4P-600W-IP:55 600 1400 3.300 60x60x60 581,00 769,00
54
55O ...
400V/50Hz ( ) . 4 6 :55, F -20oC +40oC
- T - 400V/50Hz CBM-RE TRI
EXTERNAL ROTOR CENTRIFUGAL FANS400V/50Hz
W
rpm
m3/h
. F/Smm
( x x )
TIMH
( )
TIMH
FAN SECTION
240/
180
CBM-RE-9/7 4P-550W TRI 550 1400 3.390 60x60x60 539,00 695,00
240/
240 CBM-RE-9/9 6P-245W TRI 245 900 3.330 60x60x61 514,00 670,00
CBM-RE-9/9 4P-550W TRI 550 1400 4.790 60x60x60 599,00 755,00
270/
200
CBM-RE-10/8 6P-245W TRI 245 900 3.450 60x60x60 524,00 680,00
CBM-RE-10/8 6P-350W TRI 350 900 4.300 60x60x60 552,00 708,00
CBM-RE-10/8 RE 4P-550W TRI 550 1400 4.300 60x60x60 641,00 797,00
270/
270
CBM-RE-10/10 6P-245W TRI 245 900 3.900 60x60x60 537,00 725,00
CBM-RE-10/10 6P-350W TRI 350 900 5.000 60x60x60 556,00 744,00
CBM-RE-10/10 4P-550W TRI 550 1400 4.000 60x60x60 623,00 811,00
CBM-RE-10/10 4P-750W TRI 750 1400 5.450 60x60x60 894,00 1.082,00
320/
320 CBM-RE-12/12 T 6P-550W TRI 550 900 6.250 70x70x70 685,00 879,00
CBM-RE-12/12 T 6P-1100W TRI 1100 900 7.200 70x70x70 1.168,00 1.362,00
O ...56 O ... 57
BA CBM, CBP
CBM & CBP (FAN SECTION).
A .
(2 ) .
CBM, CBPKATA (inches)
(mm)
( )
-50 7/7, 9/7 475 x 475 x 475 92,00
-60 9/7, 9/9, 10/8, 10/10 575 x 575 x 575 111,00
-70 10/8, 10/10, 12/9, 12/12 675 x 675 x 675 131,00
-80 12/12, 15/15 800 x 800 x 800 183,00
-100 15/15, 18/18 1000 x 1000 x 1000 234,00
-100/120 18/18 1000 x 1000 x 1200 300,00
CBM, CBP
. () , 1 cm, ( ). . , , .
To .
: :
K () ,
, ,
..
FAN BOX
MOUNTING FEET FOR CBM, CBP
E E
7/7 8,10 7/7, 9/7 13,30
9/7, 9/9 8,60 9/9 13,90
10/8, 10/10 12,10 10/8, 10/10 15,60
12/9, 12/12 18,40 12/9, 12/12 19,60
15/15 20,70 15/11, 15/15 23,50
18/18 35,30 18/18 26,10
O ... 57O ...56 O ... 57
CBM small
LOW PRESSURE CBM SMALL
230V/50Hz, 2 4 . .
siroco P:44, .
:
E (FAN SECTION).
: REB 5000W 2 .
TY.
WATT
rpm
F/V
MAXAmpere
m3/h
OC
dB(A) BAkg
MONH 2
CBM/2-133/046 - 90W 90 2100 2/400 0,4 260 -15/+70 58 1,8 104,00 193,00
CBM/2-133/062 - 100W 100 1650 2/400 0,4 290 -15/+40 55 1,9 105,00 194,00
CBM/2-140/059 - 100W 100 1350 2/400 0,5 390 -15/+40 48 2,6 116,00 205,00
CBM/2-140/059 - 155W 155 2300 5/400 0,7 510 -15/+70 60 3,4 141,00 234,00
CBM/2-160/062 - 260W 260 2100 6/400 1,1 630 -15/+40 62 4 153,00 246,00
MONH 4
CBM/4-160/062 - 70W 70 1320 2/400 0,3 450 -15/+60 55 3 127,00 223,00
CBM/4-180/075 - 115W 115 1330 3/400 0,6 650 -15/+55 59 3,5 140,00 236,00
CBM/4-180/092 - 160W 160 1275 6/400 0,8 970 -15/+40 57 6,5 154,00 257,00
2
CBM/2-133/190 - 185W 185 1750 5/400 0,8 630 -15/+45 57 3,5 134,00 231,00
4
CBM/4-133/190 - 70W 70 1150 2/400 0,3 640 -15/+65 47 2,8 113,00 203,00
CBM/4-160/150 - 125W 125 1150 3/400 0,6 800 -15/+65 54 3,7 153,00 242,00
CBM/4-180/184 - 150W 150 1250 5/400 1,1 1.330 -15/+60 57 5 199,00 288,00
6
CBM/6-180/184 - 95W 95 850 2/400 0,5 970 -15/+40 48 5 155,00 244,00
FAN SECTION
AA FAN SECTION
O ...58 O ... 59
FRF
230V-50/60Hz Mo M 2 4 IP:44,
CENTRIFUGAL FANSWITH EXTERNAL ROTOR MOTOR
E: , , ..
: - M , , () , RAL ..
-
-F
.
W
AMBERE
m3/h
RPM
dB ()
MAX.-
OC
kg
TIMH
FRF2C-120/062 K010 506022
7580
0,350,36
270285
23002350
6570
7560
2,9 91,00
FRF2C-133/042 K010 506022
85100
0,380,44
240225
21502100
6565
7060
2,8 92,00
FRF2C-133/046 K010 506022
90105
0,400,45
245230
21002075
6464
7060
2,8 95,00
FRF2C-133/062 K010 506022
10085
0,470,37
280260
16501725
6263
4060
2,9 96,00
FRF2C-140/059 K147 506044
140160
0,630,70
450435
19402000
6565
5040 4,4 122,00
-
-F
.
W
AMBER
m3/h
RPM
dB ()
MAX.-
OC
kg
TIMH
FRF4C-140/060 K286 50 1,5 180 0,11 230 815 46 95 4,5 104,00
FRF4C-160/062 K30 50602,52,5
7080
0,330,36
405480
13201450
6668
7070
4,3 106,00
FRF4C-180/092 - 160W 50 6 160 0,84 1.100 1380 59,5 40 6,9 123,00
4
2
O ... 59
centrifugal fans
O ...58 O ... 59
E FRB
480 - 900 m3/h
CENTRIFUGAL FANS WITH EXTERNAL ROTOR MOTOR
-
F
W
AMBERE
m3/h
RPM
dB
MAX.-
OC
BAkg
TIMH
FRB2C-175/060 K015 506022
6075
0,280,34
480525
25352700
7065
7065
2,5 101,00
FRB2C-190/060 K010 506022
6590
0,300,40
600625
25002600
7172
7560
2,3 113,00
FRB2C-220/063 K132 506022
75100
0,340,43
780900
25302800
7072
5550
2,8 119,00
2
-
F
W
AMBERE
m3/h
RPM
dB
MAX.-
OC
BAkg
TIMH
FRB4C-225/062 K081 50601,51
4030
0,180,15
425490
14001650
5055
5580
3,4 99,00
FRB4C-250/084 K110 50601,51
4553
0,200,26
820900
14001575
6163
7580
3,9 124,00
4
230V-50/60Hz M 2 4 IP:44,
E: , , ..
: - M , , () ..
FRB PERFORMANCE CURVES FRB
No 3 FRB2C - 175/060
No 5 FRB2C - 190/060
No 6 FRB2C - 220/063
No 2 FRB4C - 225/062
No 5 FRB4C - 250/084
O ...60 O ... 61
CENTRIFUGAL BLOWERS
rpm
WMAXIMUM
OC
m3/h IKH H
Pa
mm
mm
TIM
KOS-001 1400 5 40O 150 50 50x55 97 47,00
KOS-002 2500 30 40O 300 100 50x55 97 72,00
CAA-07-003 2150 28 60O 73 105 33x54 76 27,00
CAA-10B 2180 82 50O 190 260 78x96 108 56,00
VCE-12R 1900 57 40O 260 230 81x65 120 93,00
VCE-14 H15R 1750 120 40O 420 350 90x103 140 101,00
E: , , ..
(mm)CAA-07
VCE - 12R
DIMENSIONS(mm)CAA-10
VCE - 14H
Mo 230V/50/60Hz VCE
KOS C-07 C-10 VCE-12R VCE-14H
O ... 61
centrifugal fans
O ...60 O ... 61
CAF
230V - 50Hz
+90 C
SMOKE EXTRACTOR CENTRIFUGAL FANS
O.
W
TAXYTHTA RPM min-1
AMPERE K m3/h
pa
TIM *
CAF15C-001 BF 32 2400 0,12 F 180 300 97,00
CAF15Y-001 BF 39 2650 0,36 H 170 300 65,00
CAF 15C
CAF 15Y
CAF 15C-001 BF CAF 15Y-001 BF
62 O ...
HP .
mm
m3/hVOLT
mmTIM *
FKSB/2-100/025 0,25 100 450 230 108 x 42 152,00
FKSB/2-120/025FKST/2-120/025
0,25 120 800230
133 x 52 156,00400
FKSB/2-120/050FKST/2-120/050
0,50 120 1.600230
160 x 62 202,00400
FKSB/2-140/075FKST/2-140/075
0,75 140 2.500230
180 x 74 210,00400
FKSB/2-160/150FKST/2-160/150
1,50 160 3.500230
200 x 83 288,00400
FKSB/2-180/200FKST/2-180/200
2 180 3.200230
225 x 92 365,00400
() 1400 2800 FKS
A .
.
, .
, .
, , ...
: 230V, 1400 rpm REB 5000W. 2800 rpm . 400V INVERTER.
: .
- RAL .
450 - 3.200 m3/h
SINGLE INLET DIRECT DRIVE FANS
FKSB=230V FKST=400V
ME MOTE 2 , 2800 RPM
ME MOTE 4 , 1400 RPM
HP .
mm
m3/hVOLT
mmTIM *
FKSB/4-120/025FKST/4-120/025
0,25 120 450230
133 x 52 149,00400
FKSB/4-120/050FKST/4-120/050
0,50 120 900230
160 x 62 190,00400
FKSB/4-140/050FKST/4-140/050
0,50 140 1.250230
180 x 74 194,00400
FKSB/4-160/050FKST/4-160/050
0,50 160 1.750230
200 x 83 206,00400
FKSB/4-180/050FKST/4-180/050
0,50 180 2.550230
225 x 92 215,00400
* ! .
63O ...
() FKSG
A .
.
.
SINGLE INLET DIRECT DRIVE FANS
1.700 - 4.950 m3/h
: 230V, 1400 rpm REB - 5000W. 400V INVERTER.
: - . - 2 . - RAL .
HP .
mm
m3/hVOLT
mmTIM *
FKSGB/4-200/050FKSGT/4-200/050
0,50 200 1.700230
240 x 102 203,00400
FKSGB/4-200/100FKSGT/4-200/100
1 200 2.200230
250 x 102 259,00400
FKSGB/4-250/150FKSGB/4-250/150
1,50 250 3.700230
315 x 128 335,00400
FKSGB/4-300/200FKSGT/4-300/200
2 300 4.950230
355 x 143 442,00400
FKSGB=230V FKSGT=400V
x
mm
TIM
RS-124x52 32o 23,00
RS-133x52 36o 24,00
RS-146x55 40o 39,00
RS-160x62 36o 31,00
RS-180x74 40o 37,00
RS-200x83 38o 57,00
RS-225x92 42o 74,00
RS-250x102 38o 122,00
RS-280x114 42o 145,00
RS-315x128 38o 175,00
RS-355x143 42o 198,00
RS-400x163 35o 430,00
RS-450x183 42o 490,00
RS-500x204 38o 560,00
RS-560x229 42o 680,00
FKS-FKSG RS
.
E: FKS
........................................................................................................................................................................................
* ! .
64 O ...
AMPER
rpm
W
m3/h IKH H
mm H2OdB(A) TIM
BLOWER-2 1 2750 180 90 13,5 66 65,00
BLOWER-21/2 1,6 2750 260 162 17,9 68 88,00
BLOWER-3 1,8 2750 350 276 21 77 119,00
BLOWER-4 2,6 2750 350 504 24 90 231,00
BLOWER
230V, 50Hz.
.
.
.
.
.
: .90 - 504 m3/h
BLOWER
(mm) DIMENSIONS (mm)
KAM PERFORMANCE CURVES
C D F G K H1 H2 H3 L1 L2 n-d
2 BLOWER 202 55 108 42 27 105 55.5 18 208 110 35 165 55 4-6
21/2 BLOWER 252 50 145 65 47 128 70 20 260 144 50 198 70 4-6
3 BLOWER 276 54 173 73 57 147 80.5 24 295 160 62 251 75 4-6
4 BLOWER 330 80 175 122 80 182 106 31 340 188 90 323 105 4-7
DIMENSIONS
H - C-
rpmWATT
oC
m3/h
Mmm
dB(A) kg
TIM
CSB-60 2750 200 +70 310 60 68 6,60 457,00
CST-60 2750 180 +120 310 60 69 6,50 437,00
CBT-80 N 2800 370 +120 730 80 71 14,50 646,00
CBT-100 N 2800 750 +120 1.250 100 78 19,50 785,00
CBT-130 N 2800 1100 +120 1.910 130 80 27,50 1.352,00
CBT-160 2800 3000 +80 2700 160 80 44,50
CBT-170 2800 4000 +80 3800 170 81 55,50
. 120 C . CSB/T: IP: 44, . CBT: IP: 55, F. . .
E: K .
H: 400V INVERTER.
310 - 1.910 m3/h
CENTRIFUGAL DIRECT DRIVE FANS(for high pressure)
PERFORMANCE CURVES
K COMPACT
.
: 2 .
O ... 65
O ...66 O ... 67
A () 1400 F - 1400 RPM
.
, . .
E: , , ..
: 230V, 1400 rpm REB - 5000W. 400V INVERTER.
: , , , , Inverter
: - . - 2 - RAL .
2.500 - 16.000 m3/h
SINGLE INLET DIRECT DRIVE FANS SPECIAL TYPE IMPELLER
STANDARD
HP .
mm
m3/hVOLT
F/S (cm)
TIM *A/
TIM * F/S
FKKB/4-200/0500,5 200 2.500
23070x70x70
198,00 530,00
FKKT/4-200/050 400 195,00 527,00
FKKB/4-250/100FKKT/4-250/100
1 250 5.000230
70x70x70235,00 645,00
400 230,00 640,00
FKKB/4-250/1501,5 250 6.000
23080x80x80
310,00 720,00
FKKT/4-250/150 400 300, 00 710,00
FKKB/4-300/2002 300 8.000
23090x90x90
428,00 960,00
FKKT/4-300/200 400 420,00 952,00
FKKB/4-350/300FKKT/4-350/300
3 350 9.000230
100x100x100560,00 1.100,00
400 545,00 1.085,00
FKKT/4-350/400 4 350 11.000 400 100x100x100 568,00 1.100,00
FKKT/4-400/550 5,5 400 13.000 400 100x100x100 755,00 1.250,00
FKKT/4-450/750 7,5 450 16.000 400 120x100x100 1.140,00 1.950,00
() .
* FAN SECTION (F/S). 10mm . .
POSITIONS
F/S-FKK
1400 RPM 4 POLE
, .
RAL
* ! .
O ... 67
centrifugal fans
O ...66 O ... 67
HP
. mm
m3/h
VOLT F/S cm
TIM * /
T R
SIEMENS
TIM * F/S
FKKB/6-250/0500,5 250 4.000
23070x70x70
250,00 278,00 620,00
FKKT/6-250/050 400 243,00 270,00 612,00
FKKB/6-300/1001 300 6.000
230100x100x100
364,00 420,00 848,00
FKKT/6-300/100 400 356,00 410,00 840,00
FKKB/6-300/1501,5 300 8.000
230100x100x100
463,00 580,00 998,00
FKKT/6-300/150 400 449,00 520,00 990,00
FKKB/6-350/200FKKT/6-350/200
2 350 10.000230
100x100x100589,00 668,00 1.100,00
400 575,00 660,00 1.052,00
FKKT/6-400/300 3 400 11.000 400 100x100x100 690,00 815,00 1.100,00
FKKT/6-450/550 5,5 450 16.000 400 120x120x120 1.354,00 1.520,00 2.200,00
* (, , , , ..)
A () 950 F - 950 RPM
.
, . .
E: , , ..
: 230V, 950 rpm . 400V INVERTER.
: - . - 2 - RAL .
SINGLE INLET DIRECT DRIVE FANS SPECIAL TYPE IMPELLER
950 RPM 6 POLE
TO 2
FK =
=
= 400V = 230V
4 = 1400 rpm 6 = 900 rpm
FK B / 4 - 200/050
200 = . mm
050 = HP
4.000 - 16.000 m3/h
() .
F/S - FKK
* ! .
O ...68 O ... 69
ANO ME () 950 1450 FKKI
. , .
().
E: .
: 230V, 1400 rpm REB - 5000W. 900 rpm . 400V REB - 5 INVERTER.
KATO : M . .
2.500 - 16.000 m3/h
INOX SINGLE INLET DIRECT DRIVE FANS SPECIAL TYPE IMPELLER
ME MOTE 4 , 1400 RPM
HP .
mm
m3/hVOLT TIM *
T R
SIEMENS*FKKBI /6-250/050
0,5 250 4.000230 440,00 470,00
FKKTI /6-250/050 400 430,00 458,00
FKKBI /6-300/1001 300 6.000
230 650,00 688,00
FKKTI /6-300/100 400 640,00 670,00
FKKBI /6-300/1501,5 300 8.000
230 770,00 830,00
FKKTI /6-300/150 400 760,00 820,00
FKKI /6-350/200FKKTI /6-350/200
2 350 10.000230 1.150,00 1.240,00400 1.135,00 1.200,00
FKKTI /6-400/300 3 400 11.000 400 1.280,00 1.350,00
FKKTI /6-400/550 5,5 450 15.000 400 2.476,00 2.550,00
ME MOTE 6 , 950 RPM
HP .
mm
m3/hVOLT TIM *
T R
SIEMENS*
FKKBI /4-200/050FKKTI /4-200/050
0,5 200 2.500230 378,00 420,00
400 370,00 410,00
FKKBI /4-250/100FKKTI /4-250/100
1 250 5.000230 460,00 540,00
400 452,00 530,00
FKKBI /4-250/150FKKTI /4-250/150
1,5 250 6.000230 558,00 608,00
400 550,00 600,00
FKKBI /4-300/200FKKTI /4-300/200
2 300 8.000230 668,00 780,00400 660,00 770,00
FKKBI /4-350/300FKKTI /4-350/300
3 350 9.000230 920,00 1.070,00400 890,00 1.055,00
FKKTI /4-350/400 4 350 11.000 400 1.050,00 1.270,00FKKTI /4-400/550 5,5 400 13.000 400 1.340,00 1.520,00FKKTI /4-450/750 7,5 450 16.000 400 2.250,00 2.440,00
, .
* ! .
O ... 69
centrifugal fans
O ...68 O ... 69
HP .
mm
m3/hVOLT TIM *
T R
SIEMENS*FKKBI /6-250/050
0,5 250 4.000230 440,00 470,00
FKKTI /6-250/050 400 430,00 458,00
FKKBI /6-300/1001 300 6.000
230 650,00 688,00
FKKTI /6-300/100 400 640,00 670,00
FKKBI /6-300/1501,5 300 8.000
230 770,00 830,00
FKKTI /6-300/150 400 760,00 820,00
FKKI /6-350/200FKKTI /6-350/200
2 350 10.000230 1.150,00 1.240,00400 1.135,00 1.200,00
FKKTI /6-400/300 3 400 11.000 400 1.280,00 1.350,00
FKKTI /6-400/550 5,5 450 15.000 400 2.476,00 2.550,00
HP .
mm
m3/hVOLT TIM *
T R
SIEMENS*
FKKBI /4-200/050FKKTI /4-200/050
0,5 200 2.500230 378,00 420,00
400 370,00 410,00
FKKBI /4-250/100FKKTI /4-250/100
1 250 5.000230 460,00 540,00
400 452,00 530,00
FKKBI /4-250/150FKKTI /4-250/150
1,5 250 6.000230 558,00 608,00
400 550,00 600,00
FKKBI /4-300/200FKKTI /4-300/200
2 300 8.000230 668,00 780,00
400 660,00 770,00
FKKBI /4-350/300FKKTI /4-350/300
3 350 9.000230 920,00 1.070,00
400 890,00 1.055,00
FKKTI /4-350/400 4 350 11.000 400 1.050,00 1.270,00FKKTI /4-400/550 5,5 400 13.000 400 1.340,00 1.520,00FKKTI /4-450/750 7,5 450 16.000 400 2.250,00 2.440,00
FKK RK
(RD) (LG)TY P RPM
.
mm
.
mm
mm
TIM
RK/4-200/050 0,5 1400 14 305 120 48,00
RK/4-250/100 1 1400 19 340 140 62,00
RK/4-250/150 1,5 1400 24 (230V) 340 140 62,00
RK/4-300/200 2 1400 24 415 160 88,00
RK/4-350/300 3 1400 28 430 170 94,00
RK/4-350/400 4 1400 28 430 170 144,00
RK/4-400/550 5,5 1400 28 450 170 169,00
RK/4-450/750 7,5 1400 38 500 260 288,00
E: FKK, FKK/BD
: K
TY P RPM.
mm
.
mm
mm
TIM
RK/6-250/050 0,5 900 19 340 140 62,00
RK/6-300/100 1 900 24 415 160 79,00
RK/6-300/150 1,5 900 28 (400V) 415 160 107,00
RK/6-350/200 2 900 28 430 170 119,00
RK/6-400/300 3 900 28 460 170 144,00
RK/6-450/550 5,5 900 38 550 230 326,00
Y
S-200/250 25,00
S-250/300 33,00
S-300/350 39,00
S-350/400 44,00
K-200 24,00
K-250 27,00
K-300 32,00
K-350 40,00
K-400 43,00
K-450 51,00
K
O ...70 O ... 71
0.00 0.01 0.03 0.04 0.06 m3/s
0 40 80 120 160 200 240 m3/h0
5
10
15
20
25
30
0
50
100
150
200
250
300
ENTO ACOUSTIC BOX
TY
rpm
WATT
m3/h
dB (A)()
mm
x x
mm
kg
TIMH
CAB-125 1600 48 240 30 125 273 x 388 x 395 16 405,00
CAB-160 2350 100 390 36 160 273 x 388 x 395 18 430,00
CAB-200 2000 180 695 37 200 328 x 430 x 365 22 464,00
CAB-250 1250 200 1.250 38 250 383 x 525 x 450 25 569,00
CAB-315 1400 500 2.100 40 315 443 x 600 x 505 33 785,00
CAB-400 1400 1100 3.500 43 400 513 x 660 x 600 35 882,00
230V - 50Hz.
(coustic foam) 5 cm .
CAB - 125 CAB - 160 . CAB - 200, 250, 315 400 .
: , , ..
.
: REB - 5000W
240 - 3.500 m3/h
ACOUSTIC CABINET FANS (FORWARD CURVED)
CAB PERFORMANCE CURVES CAB
- .
O ... 71
centrifugal fans
O ...70 O ... 71
CAB ECOWATT
COUSTIC CABINET FANS BACKWARD CURVED SINGLE INLET
ENERGYEFFICIENT
VENTILATIONSYSTEM
Mo230V-50Hz K 5cm(M0). . . C, IP:44 . -FF . REB-ECOWATT 0-10V..
VOLT
rpm
Max .
w
Max .Ampere
m3/h
B(Kg)
TIM
dB(A)
CAB-125 ECOWATT
10 2970 66 0,5 485 37
13,1 8 2600 46 0,3 420 356 1975 23 0,2 320 304 1400 11 0,1 230 24
CAB-150 ECOWATT
10 2975 94 0,7 610 40
15,2 8 2630 66 0,5 540 406 1985 31 0,2 400 384 1400 14 0,1 280 37
CAB-160 ECOWATT
10 2975 103 0,7 675 40
15,2 8 2585 69 0,5 600 406 1950 32 0,3 445 394 1390 14 0,1 310 37
CAB-200 ECOWATT
10 2570 161 1,1 1.090 39
22,8 8 2195 100 0,7 910 366 1715 50 0,4 710 314 1250 23 0,2 520 26
CAB-250 ECOWATT
10 2650 219 1,4 1220 42
24,5 8 2390 162 1,1 1100 296 1905 85 0,6 880 274 1410 40 0,3 660 21
CAB-315 ECOWATT
10 1990 238 1,0 1.910 52
28,5 8 1670 143 0,6 1.610 486 1390 88 0,4 1.360 404 1060 46 0,2 1.010 35
CAB-355 ECOWATT
10 1940 335 1,4 2.80 49
32,5 8 1685 224 1,0 2.260 466 1380 130 0,6 1.840 394 1070 69 0,3 1.440 33
CAB-400 ECOWATT
10 1940 335 1,4 2.650 48
32,5 8 1695 229 1,1 2.320 486 1380 131 0,6 1.900 404 1070 68 0,3 1.460 35
(mm) DIMENSIONS (mm)
O ...72
THERMOBOX
centrifugal thermobox
CBM.
+80C, +70C, +10C,
. .
: .
: 230V REB - 5000W, 400V VERTER.
m3/h
cm
CAL
em3/h
. mm h2o
e
C
-
. f/S+
cm
tim
t-box/4-7/7 1/5 1500 40 x 45 x 2R 15.800 1,6 150 45 7/8 6 60 x 60 x 60
t-box/6-9/7 1/3 2500 50 x 55 x 2R 26.000 2,6 500 44 7/8 6 70 x 70 x 70
t-box/6-9/7 1/3 2500 50 x 55 x 3R 30.500 3,1 190 50 11/8 11 70 x 70 x 70
t-box/6-9/9 1/3 3000 50 x 55 x 3R 34.600 3,5 230 48 11/8 11 70 x 70 x 70
t-box/6-9/9 1/3 3000 60 x 65 x 3R 38.600 3,9 240 53 11/8 13 70 x 70 x 70
t-box/6-10/10 1/2 4500 60 x 65 x 3R 51.000 5,2 400 48 11/8 13 70 x 70 x 70
t-box/6-10/10 1/2 4500 70 x 75 x 3R 56.000 5,8 410 52 13/8 15 70 x 70 x 70
t-box/6-12/12 3/4 4800 70 x 75 x 3R 64.000 6,6 510 54 13/8 15 80 x 80 x 80
O ... 73
centrifugal fans
O ... 73
THERMOBOX
centrifugal thermobox
CBM.
+80C, +70C, +10C,
. .
: .
: 230V REB - 5000W, 400V VERTER.
m3/h
cm
CAL
em3/h
. mm h2o
e
C
-
. f/S+
cm
tim
t-box/4-7/7 1/5 1500 40 x 45 x 2R 15.800 1,6 150 45 7/8 6 60 x 60 x 60
t-box/6-9/7 1/3 2500 50 x 55 x 2R 26.000 2,6 500 44 7/8 6 70 x 70 x 70
t-box/6-9/7 1/3 2500 50 x 55 x 3R 30.500 3,1 190 50 11/8 11 70 x 70 x 70
t-box/6-9/9 1/3 3000 50 x 55 x 3R 34.600 3,5 230 48 11/8 11 70 x 70 x 70
t-box/6-9/9 1/3 3000 60 x 65 x 3R 38.600 3,9 240 53 11/8 13 70 x 70 x 70
t-box/6-10/10 1/2 4500 60 x 65 x 3R 51.000 5,2 400 48 11/8 13 70 x 70 x 70
t-box/6-10/10 1/2 4500 70 x 75 x 3R 56.000 5,8 410 52 13/8 15 70 x 70 x 70
t-box/6-12/12 3/4 4800 70 x 75 x 3R 64.000 6,6 510 54 13/8 15 80 x 80 x 80
CHEMINAIR
rpm
WATT
m3/h
mm
kg
timh
cheminair 400 1100 65 400 125 6,0 372,30
cheminair 600 1050 100 600 160 7,7 415,00
c D f g h J
cheminair 400 292 238 238 125 275 283 136 180 75
cheminair 600 343 278 258 160 315 283 154 214 92
energYefficient
VentilationSYStem
ia (mm) DimenSionS (mm) KAM
Performance curVe
230V, 50Hz. . 0C - 90C. 180C. .
: .
: .
centrifugal fanS for firePlaceS
230V/50Hz 4 5600/400 400V/50Hz 4 6 .
(). IP: 55. - F . .
: , , , , . - , .
A MONH ME CVAB/T
TY
rpmWATT
AMBER m3/h
dB (A)()
mm
mm
Kg
TIMH
CVAB/4-700/200 1375 62 0,30 690 32 200 400 x 400 26 803,00
CVAB/4-1200/250 1340 115 0,57 1.150 35 250 450 x 450 30 876,00
CVAB/4-1500/250 1380 160 0,72 1.520 42 250 500 x 500 38 986,00
CVAB/4-2600/355 1350 275 1,20 2.600 42 355 550 x 550 46 1.094,00
CVAB/4-3800/355 1380 570 2,60 3.750 48 355 650 x 650 62 1.241,00
CVAB/4-5600/400 1380 1.100 4,80 5.600 52 400 800 x 800 94 1.475,00
CVAT/4-9000/500 1475 2.050 4,80 8.800 60 500 860 x 860 105 2.445,00
CVAT/6-10000/630 975 1.500 3,90 10.000 53 630 920 x 920 120 2.703,00
CVAT/6-14000/630 965 2.500 5,40 14.000 58 630 980 x 980 160 3.141,00
CVAT/6-17000/710 965 4.600 9,30 17.100 60 710 1037 x 1037 220 3.454,00
ACOUSTIC CABINET FANS BACKWARD CURVEDSINGLE INLET
PERFORMANCE CURVES
690 - 17.000 m3/h : 400C/2h 200C. CHAT.
CVAB - 230V CVAT - 400V.
: 230V REB - 5000W. 400V INVERTER.
.
. .
O ...74
centrifugal fans
O ... 75
PE A B C D E
/4- 700/200 400 270 530 200 65
/4-1200/250 450 320 580 250 65
/4-1500/250 500 370 630 250 65
/4-2600/355 550 390 680 355 65
/4-3800/355 650 490 780 355 65
/4-5600/400 800 640 930 400 65
PE A B C E L M Q Bi Ba Fi Fa
CVAT/4-9000/500 860 860 860 55 970 940 1020 500 500 430 430
CVAT/6-6000/500
CVAT/6-10000/630 920 920 920 55 1030 1000 1080 630 630 460 460
CVAT/6-14000/630 980 980 980 55 1090 1060 1140 630 630 490 490
CVAT/6-17000/710 1037 1037 1037 55 1147 1117 1197 710 710 518,5 518,5
CVAB/T (mm) DIMENSIONS CVAB/T (mm)
O ...76
CHVB
CABINET FANS FOR SMOKE EXTRACTION
.
.
To , 120C .
IP:55, F .
E: , , , , , , ..
: 230V/50z, REB-5000W 400/50z INVERTER.
( sandwich) 25mm fibre -glass M0
W
rpm
UMAMBER
UM
m3/h
dB(A) H KAMmm
( x x )
Bkg
TIM
CHVB/4-3000/315 305 1390 1,45 2.670 58 548x573x527 46 2.248,00
CHVB/4-4000/355 530 1315 2,3 4.300 64 648x673x572 75 2.464,00
CHVB/4-6000/400 1060 1370 5,05 6.480 70 798x823x572 90 2.947,00
CHVT/4-3000/315 320 1410 0,86 2.770 58 548x573x527 46 2.267,00
CHVT/4-4000/355 520 1420 1,3 4.310 64 648x673x572 75 2.474,00
CHVT/4-6000/400 912 1295 1,95 6.560 70 798x823x572 90 2.941,00
SMOKEFANS
CHVB = 230V/50Hz CHVT= 400V/50Hz
2.670 - 6.560 m3/h
air to air heat exchengers
O ... 77
centrifugal fans
CHVB PERFORMANCE CURVES CHVB
O ...78
400oC/2h CVHT
. +400C 2
+200C. . sciroco o .
E: , ..
: 3W 230/400V, 50Hz. T 400V/50Hz . 1W. . 2 .
BELT DRIVEN CABINET FANS 400oC/2h RATED
TY
MOTER TAXYTHTA
max kg
TIMH
minkw
maxkw
minrpm
maxrpm
minm3/h
maxm3/h
CVHT-9/9 0,25 1,1 800 1700 700 4.400 60
CVHT-10/10 0,25 2,2 700 1700 1.100 6.300 70
CVHT-12/12 0,37 3,0 600 1500 1.300 9.300 85
CVHT-15/15 0,75 4,0 600 1200 3.000 12.000 121
CVHT-18/18 0,75 7,5 400 950 2.500 21.200 160
CVHT-20/20 2,2 7,5 500 1000 4.500 24.400 250
CVHT-22/22 2,2 15,0 400 850 5.000 36.000 320
CVHT-25/25 2,2 15,0 350 750 5.000 42.000 330
CVHT-30/28 2,2 18,5 300 600 12.000 57.000 648
700 - 57.000 m3/h
HORIZONTAL DISCHARGE
VERTICAL DISCHARGE
IP:55 .
SMOKEFANS
centrifugal fans
O ... 79
CVHT PERFORMANCE CURVES CVHT
O ...80
H CTR
,
, .
2 , 400V - 50Hz
IP: 55, F.
.
E: K ,
, , ..
: 150C
.
xell T3 xdllBT5
xdllCT4
CENTRIFUGAL DIRECT DRIVE FANS(for high pressure)
80C
rpm
KWAMBER
(A)
m3/hdB(A) B
(Kg)TIM
CBTR/2-351-1,1 2850 1,1 2,50 1.510 69 34 1.055,00
CBTR/2-401-2,2 2885 2,2 4,40 2.410 73 41 1.239,00
CBTR/2-452-3 2900 3 5,95 3.060 15 106 1.925,00
CBTR/2-501-7,5 2855 7,5 13,90 5.400 80 106 2.505,00
1.700 - 6.600 m3/h
E
431
CBTR
Cent
rifug
al d
irect
driv
e fa
ns
A P P L I C A T I O N S
Garages Commercial or industrial drying
installations
Car industry/ furnace
ventilation
Cooling of motors,compressors or other electrical
machines
Iron and steel industries Foundries
CONTINUOUS
OPERATION
Dusttransport
centrifugal fans
O ... 81
(mm) DIMENSIONS (mm)
CBR PERFORMANCE CURVES CBTR
O ...82
HP .
mm
mm
m3/hVOLT TIM *
FKYT/2-200/200 2 200 310 1.360 380 590,00
FKYT/2-220/300 3 220 310 1.800 380 690,00
FKYT/2-228/550 5,5 228 400 3.660 380 890,00
FKYT/2-250/750 7,5 250 400 4.500 380 1.050,00
FKYT/2-280/1000 10 280 485 5.000 380 1.200,00
FKYT/2-280/1200 12,5 280 485 6.000 380 1.300,00
FKYT/2-300/1500 15 300 485 6.500 380 1.740,00
FKYT/2-350/2000 20 350 575 6.300 380 2.390,00
FKYT/2-350/2500 25 350 575 7.800 380 2.590,00
Y 2800 FK
440V/50Hz.
, .
.
radial.
.
E: . (, , ..)
: INVERTER.
(, , , , ..)
1.360 - 7.800 m3/h
SINGLE INLET DIRECT DRIVE FANS WITH RADIAL CENTRIFUGAL IMPELLER
FK =
Y = radial
= 400V
2 = 2800 rpm
FK Y T / 2 - 200/050
200 = . mm
050 = HP . 050=0,5HP
* ! .
centrifugal fans
O ... 83
SFY
.
FKY, 400V,2800rpm .
:,,.
:.7,5Hp..
/
m3/h
/
HP
mm
*
SFY-1100/1 1 1.100 1 100 696,00
SFY-1100/1SR 1+1 1.100 1 100 804,00
SFY-2200/1+1SK 1+1* 1.360 2 200 1.240,00
SFY-3200/2+2SK 2+2* 1.800 3 200 1.490,00
SFY-4228/2+2SK 2+2* 2.500 4 228 1.680,00
SFY-5228/3+3SK 3+3* 3.660 5,5 228 2.290,00
SFY-7250/4+4SK 4+4* 4.500 7,5 250 2.780,00
BAGFILTERS
radial.
* ! .
*..
O ...84
HIGH PRESSURE CENTRIFUGAL FANS
CRFT 2 4-37kW :55, F 80C 6.200m3/h 16.000Pa
: , , , 60z, 250C.
CRGT 2 3-37kW :55, F 80C 10.800m3/h 12.000Pa
: , , , 60z, 250C.
CR/CKRT 2 0,37-7,5kW :55, F 80C 7.300m3/h 3.400 Pa
: M 2 FF1
CKAT 2 0,37-15kW :55, F 80C 2.160m3/h 14.000Pa
: , , , 60z, 250C.
CRIT 2 4 15-45kW :55, F 80C 27.000m3/h 9.000 Pa
: , , , 60z, 250C.
CKFT 2 2,2-30kW :55, F 80C 5.400m3/h 13.000Pa
: , , , 60z, 250C.
290 - 2.160 m3/h
1.330 - 6.120 m3/h
1.690 -10.800 m3/h
840 -7.300 m3/h
1.650 -27.000 m3/h
1.080 - 5.400 m3/h
O ... 85
centrifugal fans
rpm. kW
MAXIMUM ABSORBED CURRENT (A)
MAXIMUM
m3/h
kg
230V 400V
CIB-97/42 2800 0,03 0,40 200 7,0
CIB-120/52 2800 0,08 0,75 535 8,0
CIB-160/62 2800 0,18 1,50 880 90,0
CIT-180/62 2800 0,55 4,20 1,35 1290 10,0
CIB - CIT
2230V-50Hz230/400v-50Hz.
KAISI-304.
.
200,225250LG-270.
:o180C.
: 2/4.PTC.EFF1.
CENTRIFUGAL FANS INOX
Model A B C D E F G H J K L
CIB-97/42 206 58 32 102 78 72 - 67 30 54 112
CIB-120/52 256 86 31 152 93 100 120 90 30 83 112
CIB-160/62 272 72 51 152 124 139 146 126 50 85 126
CIT-180/62 292 72 51 152 124 139 146 126 50 85 141
IA (mm) DIMENSIONS (mm)
mmWG
O ...86
H