42
Korins Inc. Tel:031-777-1588 Fax:031-777-1587 www.kkkk.com [email protected] G Temperature 596 º ˆ ASTM Catalog No. Range Price MW620 -38/+ 2°C PerformaTherm ASTM Thermometer 351,000 MW630 -8/32°C PerformaTherm ASTM Thermometer 323,904 MW640 25/55°C PerformaTherm ASTM Thermometer 376,464 MW650 50/80°C PerformaTherm ASTM Thermometer 376,464 MW660 75/105°C PerformaTherm ASTM Thermometer 376,560 MW6266 Full °C Set, PerformaTherm ASTM Thermometers 1,539,520 MW621 -36/+ 35°F PerformaTherm ASTM Thermometer 351,600 MW631 18/89°F PerformaTherm ASTM Thermometer 323,904 MW641 77/131°F PerformaTherm ASTM Thermometer 376,464 MW651 122/176°F PerformaTherm ASTM Thermometer 376,464 MW661 167/221°F PerformaTherm ASTM Thermometer 376,560 MW62661 Full °F Set, PerformaTherm ASTM Thermometers 1,539,520 SPECIFICATIONS Model No. Range **has aux ice pt Divisions With Report of Calibration at: MW620 -38/+ 2°C 0.1°C -37, -30, -20, -10 & 0°C ASTM S62C MW630 -8/32°C 0.1°C -7, 0, 10, 20 & 30°C ASTM S63C MW640 25-55°C** 0.1°C 0, 25, 35, 45 & 55°C ASTM S64C MW650 50/80°C** 0.1°C 0, 50, 60, 70 & 80°C ASTM S65C MW660 75/105°C** 0.1°C 0, 75, 85, 95 & 105°C ASTM S66C MW6266 Full °C Set 0.1°C All Set ASTM S62C – S66C MW621 -36/+ 35°F 0.2°F -35, -15, 0, 15 & 32°F ASTM S62F MW631 18/89°F 0.2°F 20, 32, 50, 70 & 88°F ASTM S63F MW641 77/131°F** 0.2°F 32, 80, 95, 115 & 130°F ASTM S64F MW651 122/176°F** 0.2°F 32, 125, 145, 160 & 175°F ASTM S65F MW661 167/221°F** 0.2°F 32, 168, 185, 200 & 220°F ASTM S66F MW62661 Full °F Set 0.2°f All Set ASTM S62F – S66F Á ISO 9001 Certified and ISO/IEC 17025 Accredited Laboratory Non Mercury, High Accuracy À Ì . . The non- mercury blue liquid is safer than both mercury and most traditional spirit thermometer liq- uids. The proprietary formula is biodegradable, nontoxic, noncaustic, and nonhazardous. The dark blue liquid is easily read against our white-backed stem for additional assurance against errors. Each thermometer is 100% guaranteed, when used properly, for the life of the instrument. Manufactured in full accordance with ASTM (American Society for Testing and Materials) precision specifications for ASTM thermometers with low hazard liquids.

ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

Korins Inc. Tel:031-777-1588 Fax:031-777-1587 www.kkkk.com [email protected]

G

Tem

pera

ture

596

º수은이 포함되지 않은 ASTM 정밀 기준 온도계

Catalog No. Range PriceMW620 -38/+ 2°C PerformaTherm ASTM Thermometer 351,000MW630 -8/32°C PerformaTherm ASTM Thermometer 323,904MW640 25/55°C PerformaTherm ASTM Thermometer 376,464MW650 50/80°C PerformaTherm ASTM Thermometer 376,464MW660 75/105°C PerformaTherm ASTM Thermometer 376,560MW6266 Full °C Set, PerformaTherm ASTM Thermometers 1,539,520MW621 -36/+ 35°F PerformaTherm ASTM Thermometer 351,600MW631 18/89°F PerformaTherm ASTM Thermometer 323,904MW641 77/131°F PerformaTherm ASTM Thermometer 376,464MW651 122/176°F PerformaTherm ASTM Thermometer 376,464MW661 167/221°F PerformaTherm ASTM Thermometer 376,560MW62661 Full °F Set, PerformaTherm ASTM Thermometers 1,539,520

SPECIFICATIONSModel No. Range **has aux ice pt Divisions With Report of Calibration at:

MW620 -38/+ 2°C 0.1°C -37, -30, -20, -10 & 0°C ASTM S62CMW630 -8/32°C 0.1°C -7, 0, 10, 20 & 30°C ASTM S63CMW640 25-55°C** 0.1°C 0, 25, 35, 45 & 55°C ASTM S64CMW650 50/80°C** 0.1°C 0, 50, 60, 70 & 80°C ASTM S65CMW660 75/105°C** 0.1°C 0, 75, 85, 95 & 105°C ASTM S66CMW6266 Full °C Set 0.1°C All Set ASTM S62C – S66CMW621 -36/+ 35°F 0.2°F -35, -15, 0, 15 & 32°F ASTM S62FMW631 18/89°F 0.2°F 20, 32, 50, 70 & 88°F ASTM S63FMW641 77/131°F** 0.2°F 32, 80, 95, 115 & 130°F ASTM S64FMW651 122/176°F** 0.2°F 32, 125, 145, 160 & 175°F ASTM S65FMW661 167/221°F** 0.2°F 32, 168, 185, 200 & 220°F ASTM S66FMW62661 Full °F Set 0.2°f All Set ASTM S62F – S66F

¶ Á 제조업체가 ISO 9001 규정에 의해 만든 교정 성적서 와 함께 제공 됨 Certified and ISO/IEC 17025 Accredited Laboratory

Non Mercury, High AccuracyÀ Ì이 온도계는 기준기 급의 온도계로 오차가 적고 불확실도가 낮으며 빠른 응답성의 수은이 함유되지

않은 계기로 간단하게 사용이 가능하며 편차는 최대 허용오차 이내이다. 불확실도는 보증서의 최대 예상 오차이내 이고 반응속도는 신뢰할만할 데이터를 읽기 위한 최소한의 시간을 말한다.

The non-mercury blue liquid is safer than both mercury and most traditional spirit thermometer liq-uids. The proprietary formula is biodegradable, nontoxic, noncaustic, and nonhazardous. The dark blueliquid is easily read against our white-backed stem for additional assurance against errors.

Each thermometer is 100% guaranteed, when used properly, for the life of the instrument.

Manufactured in full accordance with ASTM (American Society for Testing and Materials) precisionspecifications for ASTM thermometers with low hazard liquids.

Page 2: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

Korins Inc. Tel: 031-777-1588 Fax: 031-777-1587 Order Online www.kkkk.com [email protected]

D

Calib

ratio

n Eq

uipm

ent

274

다기능 교정기 Multi-Function Calibrator

Catalog No. Description PriceDR880 Multi-Function Calibrator 2,872,000AccessoriesDR800A Soft fabric carrying case with accessory pocket 80,000DR800B Belt clip, strap hanger 33,600DR800C NiMH batteries with charger 144,000DR800E Data logging option 288,000

다기능 교정기는 최신제품으로 튼튼하게 만들었À ¸ ¸ ç 으며 간단하게 사용이 가능한 다용도 휴대용 계기이다. 가격대 성능이 아주 뛰어난 제품으로 많은 인기있는 공정용 매개변수의 측정 및 교정용 장비로 사용한다.최 신의 사양과 기술혁신으로 다목적 용도에 사용이 가능하며 측정시간이 짧아 고객이 이용하기 아주 편리한장 비 이다.

SPECIFICATIONSElectrical Connection 4mm sockets and mini-jack thermocouple socketCalibrated Temperature 50F to 86°F (10°C to 30°C) unless otherwise statedOperating Temperature 14 to 122°F (-10°C to 50°C, 86°F to 122°F)

0.0017% FS / °F (-10°C to 10°C, 30°C to 50°C0.003% FS / °C)For ohms: 14°F to 50°F, 86°F to 122°F0.0028% FS / °F (-10°C to 10°C, 30°C to 50°C)

Storage Temperature -4°F to 158°F (-20°C to 70°C)Humidity 0% to 90% non-condensing, Def Stan 66-31, 8.6 Cat IIIShock and Vibration BS EN61010:2001, Def Stan 66-31, 8.4 Cat IIIEMC BS EN61326-1:1998 + A2:2001Safety Electrical BS EN61010:2001. Pressure Equipment

Directive (PED), Class SEP, CE markedDisplay Graphic LCD with backlightSize (l x w x h) / Weight 7.1 x 3.3 x 2 in (180 x 85 x 50mm) / 15 oz (425 g)Batteries 3 AA alkaline, >50 hours measure, >10 hours 24V source

• Å Å 신호 발생 항목은 mA, mV, V, ohms, frequency and pulses• 신호 발생과 측정 항목은 8 RTDs and 12 thermocouples• 32 Ç개개의 압력측정 1 0 inH2O to 10,000 psi (25 mbar to 700 bar)

µ 독특한 열전대 냉접점 보상회로는 주위 온도 변화에 따른 오 차를 가상적으로 교정하여 준다

• 2, 3, 4 wire RTD automatic detection• Ã동시에 2가지 수치를 표시한다• Simultaneous dual reading capability• Automatic switch test and pressure leak test• 1000 point data storage with real time clock• 24 V loop power supply• HART® loop resistor• Large backlit display• Robust and weatherproof• Compact, simple to use, easy to carry• Convenient one-handed operation• Plug/play connector for IDOS Universal Pressure Modules• Each unit comes with batteries, calibration certificate, user guide and

a set of electrical test leads

External Pressure ModulesSee page 243

Page 3: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

Korins Inc. Tel:031-777-1588 Fax: 031-777-1587 www.kkkk.com [email protected]

D

Calib

ratio

n Eq

uipm

ent

286

휴대용 다기능 교정기

Catalog No. Description PriceAM30012 Multi-function Calibrator 3,153,600AM30013 Rechargeable Battery Kit 132,800 AM30014 Charger - 115/230 VAC 540,800 AM30015 Serial Cable - Stereo to Serial connection 30,400 NISTPR44 NIST Traceable Certificate 318,400 NISTPR45 NIST Traceable Certificate with Data 400,000

• Ç실시간 다기능 교정기 • Graphical 사용자 인터페이스 • Powers a loop• 신호 발생과 측정: TC, RTD, Pulsed Transmitters• 신호 발생과 측정: 전류 , 전압, 저항, 주파수 • Accuracy depends on sensor used/simulated• Isolated read-back loop• Fuseless input protection• Battery power• Rechargeable battery optional• Expandable with APM pressure modules (see page 802)• Serial communications port

Easy-to-use multi-function calibrator withgraphical interface, signal functions for tem-perature and loop calibration, and expandablewith the external pressure modules (see page802) modules to calibrate pressureinstrumentation

SPECIFICATIONST/C Read and Simulate B, C, E, J, K, L, N, R, S, T, U, BP, XK

CJC Installed with On/Off selectionRTD Read and Simulate Pt10, Pt25, Pt50, Pt100, Pt200, Pt500,

Pt1000, Cu10, Cu50, Cu100, Ni120, YSI400Connections 2, 3, and 4-WireUser Defined Curves YESTemperature Accuracy Depends on SensorFrequency Read CPM 2 to 600

Read Hz 1 to 1000Read KHz 1 to 10Source CPM 2 to 600Source Hz 1 to 1000Source KHz 1 to 10Source Pulse 1 to 30,000

Frequency Accuracy Depends on RangeVoltage Read Isolated 0 to 30 VDC

Read Un-isolated 0 to 20 VDCSource 0 to 20 VDC

Voltage Accuracy ± 0.015% of Reading ± 2 mVCurrent Read Isolated 0 to 24 mA

Read Non-isolated 0 to 24 mASource 0 to 24 mA

Current Accuracy ± 0.015% of Reading ± 2 ?AMax Load 1000 ohmsInternal Loop Power 24 VDC (stable)Operating Temperature 14 to 122°F / -10 to 50°CStorage Temperature -4 to 158°F / -20 to 70°CSerial Communications YESUnit Dimensions (L x H x W) 9.3 x 2.1 x 3.7 in (235 x 53 x 95 mm)Unit Weight 18 oz. (510 g)Batteries (4) AAStandard deliveryIndicator Indicator, Batteries, Soft Case, Test Leads,

Manual, Traceable certification

고급 신호 교정기The AM30012 calibrator is a true multi-func-

tion calibrator. This advanced unit offers the abil-ity to read and source temperature signals, pres-sure signals, and loop signals from the palm ofyour hand. The unit is expandable through theuse of accurate pressure modules (see page 802).With the ability to read and source frequency, fewcalibrators can compare to the AM30012. Thisunit features an easy-to-read graphical user inter-face with function keys and is easy to operate aswell. The unit is delivered in a soft carrying casethat allows for operation while protected. Ashoulder strap is also supplied to allow for hands-free operation.

APM Pressure Modeules shown on page 317

Page 4: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

371Korins Inc. Tel:031-777-1588 Tel:031-777-1587 www.kkkk.com [email protected]

Calibration Equipment

D

Thermocouple and Thermocouple / Current Loop Calibrators

Catalog No. Description PriceDR821 Thermocouple Calibrator 1,320,000DR822 Thermocouple and Current Loop Calibrator 1,720,000DR800A Soft fabric carrying case with accessory pocket 80,000DR800B Belt clip, strap hanger 33,600DR800C NiMH batteries with charger 144,000DR800D RS232 Cable 76,800DR800E Data logging option 288,000

SPECIFICATIONSType Standard Accuracy * RangeK IEC 584 1.1°F (0.6°C) -454°F to 2498°F (-270°C to 1370°C)J IEC 584 0.9°F (0.5°C) -346°F to 2192°F (-210°C to 1200°C)T IEC 584 0.6°F (0.3°C) -454°F to 752°F (-270°C to 400°C)B IEC 584 1.8°F (1.0°C) 122°F to 3308°F (50°C to 1820°C)R IEC 584 1.8°F (1.0°C) -58°F to 3216°F (-50°C to 1769°C)S IEC 584 2.5°F (1.4°C) -58°F to 3216°F (-50°C to 1769°C)E IEC 584 0.7°F (0.4°C) -454°F to 1832°F (-270°C to 1000°C)N IEC 584 1.1°F (0.6°C) -454°F to 2372°F (-270°C to 1300°C)L DIN 43710 0.6°F (0.3°C) -328°F to 1652°F (-200°C to 900°C)U DIN 43710 0.6°F (0.3°C) -328°F to 1112°F (-200°C to 600°C)C 1.8°F (1.0°C) 32°F to 4208°F (0°C to 2320°C)D 1.8°F (1.0°C) 32°F to 4523°F (0°C to 2495°C)mV -10 to 100 mV

DR822 Additional SpecificationsMeasure Accuracy0 to 55.000 mA 0.02% of reading + 3 countsSwitch Detection Open and closed, 2 mA currentLoop Power Output 24 V ± 10% (35 mA maximum)HART mA Loop Resistor 250 Ω (menu selection)Dimensions 7.1" L x 3.3" W x 2" H (180mm x 85mm x 50mm)Weight 14 oz (400g)Power 3 AA alkaline (>60 hrs. frequency measure, 10 hrs mA source (24V @ 12mA)Calibrators supplied with batteries, calibration certificate, user guide, and DR822 includes a set of electrical test leads.* mid-range figure quoted

Universal Pressure Input Modules are availablefrom 10in H2O to 10,000 psi (25 mbar to 700 bar).

Input modules can be used with any compatible instrument.

Plug and Play Modules are interchangeable be-tween instruments, requiring no set-up or instrumentcalibration.

DR821 Thermocouple Calibrator• Measures or simulates thermocouple sensors• Unique Cold Junction Compensation• Advanced Features Step, ramp, maximum/minimum/average and hold

DR822 Thermocouple / Current Loop Calibrator• Provides simultaneous T/C output and mA measurement• 24 V Loop Power Supply • Automatic Switch Test • HART Resistor - Can be switched into the loop when required for a

HART digital communicator

• Measure and source thermocouples• Advanced Cold Junction compensation virtually eliminates

errors due to ambient temperature changes• mA measure, switch test and 24V loop power• Large backlit display, menu driven interface• HART® loop resistor• Robust and weatherproof• Convenient, one-handed operation

External Pressure ModulesSee page 275

Page 5: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

371Korins Inc. Tel:031-777-1588 Fax:031-777-1587 www.kkkk.com [email protected]

Calibration Equipment

D

Thermocouple and Thermocouple / Current Loop Calibrators

Catalog No. Description PriceDR821 Thermocouple Calibrator 1,320,000DR822 Thermocouple and Current Loop Calibrator 1,720,000DR800A Soft fabric carrying case with accessory pocket 80,000DR800B Belt clip, strap hanger 33,600DR800C NiMH batteries with charger 144,000DR800D RS232 Cable 76,800DR800E Data logging option 288,000

SPECIFICATIONSType Standard Accuracy * RangeK IEC 584 1.1°F (0.6°C) -454°F to 2498°F (-270°C to 1370°C)J IEC 584 0.9°F (0.5°C) -346°F to 2192°F (-210°C to 1200°C)T IEC 584 0.6°F (0.3°C) -454°F to 752°F (-270°C to 400°C)B IEC 584 1.8°F (1.0°C) 122°F to 3308°F (50°C to 1820°C)R IEC 584 1.8°F (1.0°C) -58°F to 3216°F (-50°C to 1769°C)S IEC 584 2.5°F (1.4°C) -58°F to 3216°F (-50°C to 1769°C)E IEC 584 0.7°F (0.4°C) -454°F to 1832°F (-270°C to 1000°C)N IEC 584 1.1°F (0.6°C) -454°F to 2372°F (-270°C to 1300°C)L DIN 43710 0.6°F (0.3°C) -328°F to 1652°F (-200°C to 900°C)U DIN 43710 0.6°F (0.3°C) -328°F to 1112°F (-200°C to 600°C)C 1.8°F (1.0°C) 32°F to 4208°F (0°C to 2320°C)D 1.8°F (1.0°C) 32°F to 4523°F (0°C to 2495°C)mV -10 to 100 mV

DR822 Additional SpecificationsMeasure Accuracy0 to 55.000 mA 0.02% of reading + 3 countsSwitch Detection Open and closed, 2 mA currentLoop Power Output 24 V ± 10% (35 mA maximum)HART mA Loop Resistor 250 Ω (menu selection)Dimensions 7.1" L x 3.3" W x 2" H (180mm x 85mm x 50mm)Weight 14 oz (400g)Power 3 AA alkaline (>60 hrs. frequency measure, 10 hrs mA source (24V @ 12mA)Calibrators supplied with batteries, calibration certificate, user guide, and DR822 includes a set of electrical test leads.* mid-range figure quoted

Universal Pressure Input Modules are availablefrom 10in H2O to 10,000 psi (25 mbar to 700 bar).

Input modules can be used with any compatible instrument.

Plug and Play Modules are interchangeable be-tween instruments, requiring no set-up or instrumentcalibration.

DR821 Thermocouple Calibrator• Measures or simulates thermocouple sensors• Unique Cold Junction Compensation• Advanced Features Step, ramp, maximum/minimum/average and hold

DR822 Thermocouple / Current Loop Calibrator• Provides simultaneous T/C output and mA measurement• 24 V Loop Power Supply • Automatic Switch Test • HART Resistor - Can be switched into the loop when required for a

HART digital communicator

• Measure and source thermocouples• Advanced Cold Junction compensation virtually eliminates

errors due to ambient temperature changes• mA measure, switch test and 24V loop power• Large backlit display, menu driven interface• HART® loop resistor• Robust and weatherproof• Convenient, one-handed operation

External Pressure ModulesSee page 275

Page 6: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

Korins Inc. Tel:031-777-1588 Fax:031-777-1587 www.kkkk.com [email protected]

D

Calib

ratio

n Eq

uipm

ent

372

Offering one of the widest selection of thermocouple ranges, this accurate andeasy to use calibrator provides performance found only on bulky expensive benchunits. Award winning case design is made of light-weight rugged Lexan.

A combination of operator prompts and keypad entry makes using the calibra-tor easy. The user friendly menu interface system takes you step by step through:sensor selection, input or output operation, output and ramp setting, and errorrecognition.

The patented Omincon connector accepts virtually any style connector and ishighly isothermal, providing near perfect reference junction compensation. Theunit automatically recalibrates itself every 15 seconds compensating for drift.

Multiple Thermocouple Calibrator

SPECIFICATIONSRanges J, K, T, E, N, W5/W26, Platinell II, R.S. and B

thermocouples, and millivoltsAmbient Operating Temperature 32° to 131°FTemperature Stability 30PPM of reading/°CInput Impedance 100MDisplay 2 lines of 16 alphanumeric

characters, 5x7 dot matrix,LCD 2 updates/second

Power supply 6 “AA” batteries or ACadapter

Size 8.6"H x 3.75"W x 2.38"DWeight 28oz. (including batteries)Consult Factory for full specifications

Catalog No. Description PriceTH34006 Thermocouple Calibrator 2,329,000TH34007 Test Lead Package (J, K, T, & E) 125,000TH34008 115VAC Adapter 42,000NISTPC01 NIST Traceable Certificate 125,000NISTPC02 NIST Traceable Certificate with Data 209,000

• Directly reads or generates10 thermocouple signals andmillivolts

• High accuracy, typically 0.25°• 0.1° resolution• Three output memories• Ramping on all outputs• Battery or AC operation• °F / °C selector button• 2 Year Warranty

Catalog No. Description PriceAM5741 RTD and Thermocouple Calibrator / Source and Measure 2,155,200NISTPC01 NIST Traceable Certificate 120,000NISTPC02 NIST Traceable Certificate with Data 200,000

Portable Temperature CalibratorMeasure and source 14 RTD types and13 thermocouple types

SPECIFICATIONSThermocople Ranges B, C, E, J, K, L, N, R, S, T, U, XKRTD Ranges Pt100, Pt200, Pt500, PT1000, Ni120, Pt3916,

Pt3926, Cu10, YSI400, Pt10, PT50 and Cu100Ohms Ranges (Source) 5.0 to 400.0 ohms, 400 to 4000 ohmsAccuracy Ranges from 0.1 to 1 ohmOhms Ranges (Read) 5.00 to 400.00 ohns, 400.0 to 4000.0 ohmsAccuracy Ranges from 0.1 to 1 ohmmV Ranges -10.00 to 75.00mVAccuracy ± 0.02T of reading ± 20uVCJC Control YesThermocouple Accuracy 0.4 °C typical at 0.0 °C J typeRTD Accuracy 0.2 °C typical on Pt100 rangeRTD IEX Range 0.01mA to 3mAStability ± 0.005% FS/C (<18°C or >28°C)Power Supply 1 9V batteryAM5741 Delivery Calibrator - Test Leads - Soft Carrying Case -

Shoulder Strap - Operating Manual -NIST Traceable Certificate

Page 7: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

Korins Inc. Tel:031-777-1588 Fax:031-777-1587 www.kkkk.com [email protected]

G

Tem

pera

ture

588

Precision Multi-Channel Standard Thermometer

HR1560• Reads SPRTs, RTDs, thermistors, and

thermocouples• Any configuration you like up to eight

modules • High-accuracy reference thermometer

(to ± 0.0013°C) • Automates precision data acquisition –

2 channel or multi-channel functionality• LCD screen capable of displaying data

in graphical strip chart format• RS-232 port standard; IEEE-488 port

optional

SPECIFICATIONSModel HR1560 Base UnitPower: 100 to 240 VAC, 50 or 60 Hz, nominal; Attachable Modules: up to 8; Display: 4.25” x 2.25” LCD graphics, LED backlight, adjustable contrast and bright-ness; Automatic Input Sequencing: 1 to 96 channels; Communications: RS-232; Non-volatile Memory: channel sequence, probe coefficients; Minimum SampleTime: 2 seconds.Extended Communication Module HR3560The Extended Communication Module adds additional communication interface capability to the system. This module includes a GPIB (IEEE-488) interface,Centronics printer interface, and analog output. The GPIB interface connects the HR1560 to a GPIB bus. GPIB can be used to control any function of theHR1560 and read measurement data. The printer interface allows the HR1560 to send measurement data directly to a printer. The analog output sources aDC signal (± 1.25 VDC) corresponding to the value of a measurement.Resistance ModulesInput Resistance Basic Resistance Temperature Equivalent Temperature Excitation Channels Range Resistance Resolution Range Temperature Resolution Current

Accuracy Accuracy†

SPRT Module HR25602 0Ω to 400Ω ± 20 ppm of reading 0.0001Ω –260°C to 962°C ± 0.005°C at 0°C 0.0001°C 1.0 mA,

(0.0005Ω at 25Ω, ± 0.007°C at 1.4 mA0.002Ω at 100Ω) 100°C

High-Temp PRT HRModule 25612 0Ω to 25Ω ± 50 ppm of reading 0.00001Ω 0°C to 1200°C ± 0.013°C at 0°C 0.001°C 3.0 mA,

(0.00013Ω at 2.5Ω) ± 0.018°C at 100°C 5.0 mAPRT Scanner HR25628 0Ω to 400Ω ± 40 ppm of reading 0.0001Ω –200°C to 850°C ± 0.01°C at 0°C 0.001°C 1.0 mA,

(0.004Ω at 100Ω) ± 0.014°C at 100°C 1.4 mA Standards Thermistor Module HR25632 0Ω to 1 MΩ ± 50 ppm of reading 0.1Ω –60°C to 260°C ± 0.0013°C at 0°C 0.0001°C 2 µA,

(0.5Ω at 10 KΩ) ± 0.0015°C at 75°C 10 µAThermistor Scanner HR2564 8 0Ω to 1 MΩ ± 100 ppm of reading 0.1Ω –60°C to 260°C ± 0.0025°C at 0°C 0.0001°C 2 µA,

(1Ω at 10 KΩ) ± 0.003°C at 75°C 10 µA1000Ω PRT Module HR25672 0Ω to 4 KΩ ± 25 ppm of reading 0.001Ω –260°C to 962°C ± 0.006°C at 0°C 0.0001°C 0.1 mA,

(0.025 at 1 KΩ) ± 0.009°C at 100°C 0.05 mA1000Ω PRT Scanner HR25688 0Ω to 4 KΩ ± 40 ppm of reading 0.001Ω –200°C to 850°C ± 0.01°C at 0°C 0.0001°C 0.1 mA,

(0.04 at 1 KΩ) ± 0.014°C at 100°C 0.05 mAThermocouple ModulesInput Millivolt Millivolt Millivolt Temperature Temperature Temperature Channels Range Accuracy Resolution Accuracy,† Accuracy,† Resolution

Ext. CJC Int. CJCPrecision Thermocouple Module HR25652 –10 to 100 mV ± 0.002 mV 0.0001 mV ± 0.05°C ± 0.1°C 0.001°CThermocouple Scanner HR256612 –10 to 100 mV ± 0.004 mV 0.0001 mV ± 0.1°C ± 0.3°C 0.001°C†Temperature accuracy depends on probe type and temperature.

TO ORDER, SEE NEXT PAGE

Page 8: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

589Korins Inc. Tel:031-777-1588 Fax:031-777-1587 www.kkkk.com [email protected]

Temperature

G

Catalog No. Description PriceHR1560 Thermometer Base Unit 3,880,000ModulesHR2560 SPRT Module, 25 and 100Ω 2 channel 2,576,000HR2561 High-Temp PRT Module, 0.25Ω 2-channel 2,912,000HR2562 PRT Scanner Module, 8-channel 3,096,000HR2563 Standards Thermistor Module, 2-channel 2,752,000HR2564 Thermistor Scanner Module, 8-channel 2,600,000HR2565 Precision Thermocouple Module, 2-channel 3,784,000HR2566 Thermocouple Scanner Module, 12-channel 3,096,000HR2567 PRT Module, 1000Ω, 2-channel 2,752,000HR2568 PRT Scanner Module, 8-channel2, 1000Ω 3,264,000HR3560 Extended Communications Module 1,280,000AccessoriesHR99351 LogWare II, Multi Channel, Single User 904,000HR99352 LogWare II, Multi Channel, Multi User 1,280,000HR9302 Case (Holds HR1560 and up to five modules) 528,000Probes See Page 567HR56109 Thermistor Probe, 0 to 100°C 1/8" x 9" 920,000HR56106 Thermistor Probe, 0 to 100°C 1/8" x 6" 920,000HR56129 Secondary PRT, -200 to 420°C 3/16" x 9" 1,184,000HR56136 Secondary PRT, -200 to 300°C 3/16" x 6" 1,184,000HR561412 Secondary PRT, -200 to 420°C 1/4" x 12" 1,184,000HR562812 Secondary PRT, -200 to 661°C 1/4" x 12" 2,512,000Spare ConnectorsHR2381 Standard Thermocouple Connector, 12 pcs.(X=TC type. Choose from K, T, J, E, R, S, N, or U) 72,000HR2380 Mini Thermocouple Connector, 12 pcs. (X = TC type. Choose from K, T, J, E, R, S, N, or U) 64,000HR2382 RTD/Thermistor Connector, 8 pcs. (Fits HR2562, HR2564, and HR2568 modules) 48,000

The HR1560 Black Stack can be any kind of thermometer you want it to be, and it works in three dis-tinctive ways. It’s a reference thermometer with a NIST traceable calibration; it’s an automated calibra-tion system reading your reference probe and sensors you’re testing; or it’s a high-accuracy data acquisi-tion system.

The system consists of up to eight different modules designed to do any type of thermometry youchoose. Each module stacks behind the preceding one, and when you add a module, the Stack’s softwareautomatically reconfigures itself to include all of the new functions supplied by that module. There’s nosoftware to load, and nothing has to be calibrated.

Model HR9935 Multi Channel LogWare makes the Black Stack an even more powerful data acquisi-tion tool. LogWare provides graphical and statistical analysis of each channel you’re measuring (up to 96with the Black Stack). And with alarms that can be customized, delayed start times, and selectable log-ging intervals, LogWare turns the Black Stack into the most powerful temperature data acquisition toolon the market.The Base Unit

The base module supplies power, communication management, and software coordination for all of theother modules. It has the display, control buttons, and RS-232 port built-in. Each base module can handleeight thermometer modules stacked behind it with a maximum of 96 sensor inputs. The thermometercharacteristics of each base module are defined by the thermometry modules stacked behind it.The Modules

There are nine thermometry modules: an SPRT module, a high-temp PRT module, a PRT scannermodule, a standards thermistor module, two 1000-ohm PRT modules, a thermistor scanner module, aprecision thermocouple module, and a thermocouple scanner module. Each module has its own processorand connects to the stack on a proprietary digital bus. Each retains its own calibration data and performsall analog measurement functions within the module.

Page 9: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

Korins Inc. Tel:031-777-1588 Fax:031-777-1587 www.kkkk.com [email protected]

G

Tem

pera

ture

590

SPECIFICATIONSPRT/RTD Thermistor Thermocouple

Inputs 2 channels PRT/thermistor and 2 channels TC, or 4 channels PRT/thermistor, or 4 channels TC, specify when ordering;PRT/thermistor channels accepts 2, 3, or 4 wires; TC inputs accept B, E, J, K, N, R, S, T, and Au-Pt TC types

Temperature Range -189 to 960°C -50 to 150°C -270 to 1800°CMeasurement Range 0 to 400 Ω 0 to 500 KΩ -10 to 100 mVCharacterizations ITS-90, IEC-751 (DIN ‘385’), Steinhart, Hart, NIST Monograph 175, 3-point

Callendar-Van Dusen YSI-400 deviation function applied to NIST 175, 6th-order polynomialTemperature Accuracy ± 0.004°C at -100°C ± 0.0025°C at 0°C Ext. RJC Int. RJC(meter only) ± 0.006°C at 0°C ± 0.0025°C at 25°C B at 1000°C ± 0.6°C ± 0.6°C

± 0.009°C at 100°C ± 0.004°C at 50°C E at 600°C ± 0.07°C ± 0.25°C± 0.012°C at 200°C ± 0.010°C at 75°C J at 600°C ± 0.1°C ± 0.35°C± 0.018°C at 400°C ± 0.025°C at 100°C K at 600°C ± 0.15°C ± 0.4°C± 0.024°C at 600°C N at 600°C ± 0.15°C ± 0.3°C

R at 1000°C ± 0.4°C ± 0.5°CS at 1000°C ± 0.5°C ± 0.6°CT at 200°C ± 0.1°C ± 0.3°C

Temperature Resolution 0.001° 0.0001° 0.01 to 0.001°Resistance/Voltage Accuracy 0 to 20Ω: ± 0.0005 Ω 0 to 5 KΩ: ± 0.5 Ω -10 to 50 mV: ± 0.005 mV

20 to 400 Ω: ± 25 ppm of rdg. 5 to 200 KΩ: ± 100 ppm of rdg. 50 to 100 mV: ± 100 ppm of rdg200 to 500 KΩ ± 300 ppm of rdg (Internal RJC: ± 0.25°C)

Operating Range 16 to 30°CMeasurement Interval 0.1 second to 1 hour; inputs may be read sequentially or simultaneously at 1 second or greater intervalExcitation Current 1 mA 2 and 10 µA, automatically selected n/aDisplay 1.3” x 5” backlit LCD graphical displayDisplay Units °C, °F, K, Ω, KΩ, mVData Logging Up to 8,000 time- and date-stamped measurements can be loggedLogging Intervals 0.1, 0.2, 0.5, 1, 2, 5, 10, 30, or 60 seconds; 2, 5, 10, 30 or 60 minutesAveraging Moving average of most recent 2 to 10 readings, user selectableProbe Connection Patented DWF Connectors accept spade lug, bare-wire, Universal receptacle accepts miniature and

or banana plug terminations standard connectorsCommunications RS-232 and IR ports included, IEEE-488 (GPIB) optionalAC Power 100 to 240V AC, 50-60 Hz, 0.4ADC Power 12 to 16V DC, 0.5A (battery charges during operation from 14.5 to 16V DC, 1.0A)Battery NiMH, 8 hours operation typical without backlight, 3 hours to charge, 500 cyclesSize 4.0” H x 7.5” W x 8.2” D (102 x 191 x 208 mm)Weight 4.5 lbs. (2 kg)Probes Please inquire for a wide variety of precision PRTs, Thermistors, and thermocouplesCalibration NIST-traceable resistance certificate and NIST-traceable voltage certificate

Precision 4-Channel Ç¥ÁØ 표준 온도계

• Four channels for PRT’s, thermistors, and thermocouples• Displays eight user-selected data fields from any channel• Logs up to 8,000 readings with date and time stamps• Battery provides eight hours of continuous operation

See page 5 for optional probes

Catalog No. Description PriceHR1529 Precision 4-Channel Thermometer, 2 TC and 2 PRT Inputs 6,184,000HR1529R Precision 4-Channel Thermometer, 4 PRT Inputs 6,184,000HR1529T Precision 4-Channel Thermometer, 4 TC Inputs 6,184,000Options and AccessoriesHR25061529 IEEE Option 520,000HR9935S Multi-Channel Log Ware, Single User 904,000HR9935M Multi-Channel Log Ware, Multi User 1,280,000HR2374 IR Dongle 192,000HR2375 Thermal Serial Printer 880,000HR9322 Rugged Carrying Case and 12" Probe 416,000NISTDT66 NIST Traceable Certificate 240,000NISTDT67 NIST Traceable Certificate with Data 318,400See Page 567 for Probes

Page 10: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

587Korins Inc. Tel:031-777-1588 Fax:031-777-1587 www.kkkk.com [email protected]

Temperature

G

Precision Handheld 표준 온도계

• Reads PRTs/RTDs to ± 0.025°C and thermistors to ± 0.005°C• Model HR1522 logs up to 10,000 readings on-board in multiple data sets• INFO-CON connector allows interchangeable use of calibrated

probes• INFO-CON eliminates errors from programming probe data• Reads ITS-90, DIN 385, Callendar-Van Dusen, Steinhart-Hart, and

YSI 400 thermistor curves• Battery powered package includes: RS-232 Cable, AC Power

Adapter, One INFO-CON Connector• RTD accuracy to ± 0.025°C• Thermistor accuracy to ± 0.005°C• Resolution to 0.001°

These are the first standard thermometers tofit into a battery-powered handheld package.They’re accurate to ±0.005°C!

Fitting easily into your hand and weighing onlyone pound (0.4 kg), these thermometers can goanywhere. And when they get there, you can havetotal confidence in the accuracy of your measure-ments. The HR1522 is a full datalogger, with memory to hold 10,000 readings.Model HR1521

The HR1521 uses a menu system for convenientaccess to all functions. Calibration and sensor pro-gramming functions are password protected tohelp prevent unauthorized access.

“Min” and “Max” functions store the lowest andhighest readings since the last reset. The “Hold”function freezes and stores the current reading(up to six may be stored) for later recall. And the“Delta” function computes the difference betweenthe current reading and a reference value, whichmay be recorded at any time.Model HR1522

The Model HR1522 has all the power and greatfeatures of the HR1521 plus the ability to logdata. Two data acquisition modes are on-board.

In “Auto Logging” mode, the HR1522 recordsup to 10,000 measurements, including the value,unit of measure, date, and time of each measure-ment. Measurements are recorded at any of 12 se-lectable intervals ranging from every second toevery hour.Probes

The HR1521 and HR1522 read both Pt-25 andPt-100 RTDs as well as thermistors.

PRTs, with their wide temperature ranges andstabilities, have long been favored as temperaturestandards. From -200°C to 100°C, the HR1521reads PRTs accurately to ±0.025°C. Even at800°C, these high-precision readouts are accurateto ±0.1°C.

Precision thermistors offer excellent stabilityand even greater accuracies over a more narrowrange—typically from about -10°C to 110°C. Attemperatures below 50°C, these HandheldThermometers read thermistors to ±0.005°C.Accuracy at 100°C is ±0.02°C.INFO-CON Connectors

Probes attach to the HR1521 and HR1522 usinga unique connector. The connector allows you tochange the probes you use without reprogram-ming your readout. A memory chip in the connec-tor stores all the critical information about yourprobe, including its serial number, recall date, andcalibration constants.

±0.005°C Accuracy, 0.001° Resolution

SPECIFICATIONSSensor Type Pt 25 to Pt 100 ThermistorTemperature Range -200 to 962°C Sensor DependentResistance Range 0 to 400 ohms 0 to 500K ohmsCharacterizations ITS-90, IEC-751 (DIN ‘385’), Steinhart-Hart thermistor

Callendar-Van Dusen polynomial, YSI 400 (2252 ohms)

Temperature Accuracy -200 to 100°C: ± 0.025°C 0 to 50°C: ± 0.005°C(meter only) 100 to 400°C: ± 0.05°C 50 to 75°C: ± 0.01°C

400 to 800°C: ± 0.1°C 75 to 100°C: ± 0.02°C800 to 962°C: ± 0.15°C

Operating Range 0 to 40°CTemperature Resolution 0.001°Measurement Period 1 secondCommunications RS-232 (Model 1522 also includes infrared interface)Memory Model 1521 stores 6 readings in “Hold” mode:

Model 1522 logs 10,000 readings in “Auto Log” modeand 100 readings in “Demand Log” mode (memory also holds up to 25 data labels)

Display 6-digit, 7-segment LCD with 16x1 alphanumericPower Rechargeable NiMH batteries (AC adapter included)Size 7.75” H x 4.2” W x 1.5” D (20 x 11 x 4 cm)Weight 1 lb. (0.4 kg)

Catalog No. Description PriceHR1521 Handheld Thermometer 1,768,000HR1522 Handheld Thermometer with Datalogging 2,400,000Probes See Page 567HR56276 RTD-100 Ohm, 4 Wire -200 to 300°C, 800,000

6” longHR56279 RTD-100 Ohm, 4 Wire -200 to 420°C, 800,000

9” longHR562615 RTD-100 Ohm, 4-Wire -200°C to 661°C, 2,512,000

15” longHR9321 Soft Carrying Case 184,000HR9318 Hard Carrying Case 320,000NISTDT20 NIST Traceable Certificate 120,000NISTDT21 NIST Traceable Certificate with Data 200,000

Page 11: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

591Korins Inc. Tel:031-777-1588 Fax:031-777-1587 www.kkkk.com [email protected]

Temperature

G

Each probe includes:• Individual report of calibration• Probe linearization coefficients• Programmed INFO-CON connector• Resistance vs. temperature table• Termination to match your thermometer readout

(see spec chart)

Secondary Temperature Reference Probes

SPECIFICATIONSModel Readout Type Range Size Cal Uncertainty Typical Price

and Short-Term DriftStability (1 Year)

HR562612I HR1521 or HR1522 High-Temp PRT, 100 ohm –200 to 661°C 1/4 in x 12 in ± 0.007°C at 0°C < ± 0.03°C 2,552,000HR562612D HR1502A (6.35 x 305 mm) 2,552,000HR562612L HR1529 2,552,000HR561412I HR1521 or HR1522 Secondary PRT, 100 ohm –200 to 420°C 1/4 in x 12 in ± 0.018°C at 0°C ± 0.01° 1,184,000HR561412D HR1502A (6.35 x 305 mm 1,184,000HR561412L HR152 1,184,000HR56136I HR1521 or HR1522 Secondary PRT, 100 ohm –200 to 300°C 3/16 in x 6 in ± 0.018°C at 0°C ± 0.01°C 1,184,000HR56136D HR1502A (4.76 x 152 mm) 1,184,000HR56136L HR129 1,184,000HR56129I HR1521 or HR1522 Secondary PRT, 100 ohm –200 to 420°C 3/16 in x 9 in ± 0.018°C at 0°C ± 0.01°C 1,184,000HR56129D HR1502A (4.76 x 229 mm) 1,184,000HR56129L HR1529 1,184,000HR56276I HR1521 or HR1522 RTD, 100 ohm –200 to 300°C 3/16 in x 6 in ± 0.050°C at 0°C ± 0.13°C 776,000HR56276D HR1502A (4.76 x 152 mm) 776,000HR56276L HR1529 776,000HR56279I HR1521 or HR1522 RTD, 100 ohm –200 to 420°C 3/16 in x 9 in ± 0.050°C at 0°C ± 0.13°C 776,000HR56279D HR1502A (4.76 x 229 mm) 776,000HR56279L HR1529 776,000HR562712I HR1521 or HR1522 RTD, 100 ohm –200 to 420°C 1/4 in x 12 in ± 0.050°C at 0°C ± 0.13°C 776,000HR562712D HR1502A (6.35 x 305 mm) 776,000HR562712L HR1529 776,000HR5618A9I HR1521 or HR1522 PRT, 100 ohm –200 to 500°C 1/8 in x 9 in ± 0.050°C at 0°C ± 0.01°C 1,000,000HR5618A9D HR1502A (3.2 x 229 mm) 1,000,000HR5618A9L HR1529 1,000.000HR562205I HR1521 or HR1522 Fast-response RTD –200 to 350°C 0.02 in x 4 in ± 0.15°C at 0°C, ± 0.15°C 328,000HR562205D HR1502A (0.5 x 100 mm) uncalibrated 328,000HR562205L HR1529 ± 0.04°C, calibrated* 328,000HR56109I HR1521 or HR1522 Thermistor, Stainless 0 to 100°C 1/8 in x 9 in ± 0.015°C at 0°C ± 0.01°C 920,000HR56109L HR1529 (3.2 x 229 mm) 920,000HR5611I HR1521 or HR1522 Thermistor, Bare 0 to 100°C 0.07 in x 0.55 in ± 0.015°C at 0°C ± 0.01°C 698,000HR5611L HR1529 Silicone Bead (1.8 x 14 mm) 698,000*These probes do not come with an individual certificate if a calibration is not ordered separately. Order calibration 1923-4-N if needed. For calibration, PRTcomparison, order 1923-4-N, =186 C to 300 C.

Fast, Friendly Service.Fast, Friendly Service.

Need MoreInformation about

a product?

Ask for TechnicalService.

Need MoreInformation about

a product?

Ask for TechnicalService.

Page 12: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

Korins Inc Tel:031-777-1588 Fax:031-777-1587 www.kkkk.com [email protected]

D

Calib

ratio

n Eq

uipm

ent

350

• Field portability with laboratory accuracy• Large well capacity 50 x 155 mm (2”x 6”) • RS232 interface • Built-in reference thermometer• Built into its own carrying case

As Dry Block — • Quick change in well temperature• No mess or liquids• Good stability

As Liquid Bath — • Excellent stability and accuracy• Excellent repeatability• Better capacity: accommodates sensors’ different sizes and shapes• No need to make fittings for sensors• Small temperature gradients

With Automatic Calibration — • Easy to set up• Fully automatic calibration• Graphical 1/4 VGA display• Test sensor inputs and signal conditioning for transmitters• RTD, T/C, V and mA inputs• Calibration values logged• Calibration reports produced to ISO9000

With Built-In Reference Thermometer — • Comparison method optimizes possible thermometer accuracy• Can work in true temperature by using programmable correction

tables for external references

The most complete temperature calibra-tion system ever built, this unit is designed tocombine a dry block calibrator, a liquid bathcalibrator and a reference thermometer inone uniquely portable design. Get the bestfeatures of both dry block and liquid bath inone calibrator.

Easy to set up, with a large 2" diameterwell capacity, the units excellent stability (≤ ±0.005°C) and accuracy offers a temperaturerange of -40°C below ambient to +150°C. Thefull graphic LCD display, clearly displaysreadings, and the built-in computer permits20 calibration points to be set for automaticcalibration.

This unit produces calibration reports toISO9000, and can use the standard RS232 in-terface to dump to printers. The unit uses aWindows CE operating system, and externalreference advantages incorporated into thiscalibration unit makes it possible to work intrue temperature by using correction tables.The built-in reference thermometer allows forthe easy set-up of an automatic multi-pointcalibration system.

Catalog No. Description PriceTC2000 Temperature Calibrator, -40°C below ambient to 150°C (302°F) 12,792,000TC2000INSL Liquid Insert 632,000SI9351482 Standard Reference Probe 632,000

Calibration SystemCombines Dry Block, Liquid Bath & Reference Thermometer in the Same Unit

SPECIFICATIONSField temperature range -40°C below ambient to 150°C

(-80°F below ambient to 302°F)Resolution 0.01°CGradients at 95°C w/ water ± 0.06°C

Between bottom and 25 mm from topStability (30 min. after normal stabilization)

As a dry block ± 0.02°CAs a stirred liquid bath ± 0.005°CAs a stirred ice bath ± 0.001°C

Accuracy (with internal ref.) ± 0.3°CUncertainty (best) ≤ 0.03°C (depending on ext. refer-ence)Well depth 155 mm (6”)Well diameter 50 mm (2”)Bath Volume 261 cm3

Thermostat test YesInterface RS232Power Supply (field selectable) 110 VAC (90-130V), 50/60Hz

230 VAC (180-250V), 50/60HzOperating Temperature 0 to 40°C (32 to 104°F)Dimensions 16 x 10 x 14 in.Weight (without inserts) 35 lb.

Page 13: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

Korins Inc. Tel:031-777-1588 Fax:031-777-1587 www.kkkk.com [email protected]

D

Calib

ratio

n Eq

uipm

ent

356

The Advanced Temperature Calibrators are among the most accurateand stable temperature calibrators available. The versatile units offer theuser a laboratory standard in a portable package. These units are fullyprogrammable and are supplied with the complete AMECAL softwarepackage. The model B series units allow for direct reading of virtuallyany electrical temperature sensor. The units are extremely stable and are safer than temperature baths; no liquid is necessary. The dual-zonecontrol makes up for heat losses from oddly shaped sensors.

Advanced Dry Block Temperature Calibrators

Catalog No. Model Description Bore Insert OD Material PriceAM5720 A Dry Block Calibrator, 115V with Multi-Hole Insert 3/16, 3/8, (2) 1/4, 1/8 in 0.75 in Aluminum 10,452,800 AM5721 B Dry Block Calibrator, 115V with Multi-Hole Insert 3/16, 3/8, (2) 1/4, 1/8 in 1.0 in Aluminum 13,051,200 AM5722 A Dry Block Calibrator, 115V with Multi-Hole Insert 3/16, 1/4, 1/8 in 0.75 in Aluminum 11,353,600 AM5723 B Dry Block Calibrator, 115V with Multi-Hole Insert 3/16, 1/4, 1/8 in 1.0 in Aluminum 13,952,000 AM5724 A Dry Block Calibrator, 115V with Multi-Hole Insert 3/16, 3/8, (2) 1/4, 1/8 in 0.75 in Brass 8,865,600AM5725 B Dry Block Calibrator, 115V with Multi-Hole Insert 3/16, 3/8, (2) 1/4, 1/8 in 1.0 in Brass 11,464,000 AM5726 A Dry Block Calibrator, 115V with Multi-Hole Insert 3/16, 3/8, (2) 1/4, 1/8 in 0.75 in Brass 9,817,600AM5727 B Dry Block Calibrator, 115V with Multi-Hole Insert 3/16, 3/8, (2) 1/4, 1/8 in 1.0 in Brass 12,416,000 AM5728 Carrying case for calibrators 854,400 AM5729 Basic Accessory Kit for AM5720 552,000 AM5730 Basic Accessory Kit for AM5724/AM5726 552,000 NISTTA41 NIST Traceable Certificate 328,000NISTTA42 NIST Traceable Certificate with Data 496,000Most insertion tubes include a 4 mm hole for reference probesAdditional insertion tubes available in increments from 1/8 - 7/8 in, 3 - 20 mm, and Imperial or Metric Multi-Hole sizes. Please Inquire.

SPECIFICATIONSAM5720/AM5721 AM5722/AM5723 AM5724/AM5725 AM5726/AM5727

Temperature Range Min. @73°F/23°C -11°F (-24°C) -49°F (-45°C) 91°F (33°C) 91°F (33°C)Maximum 311°F (155°C) 311°F (155°C) 608°F (320°C) 1202°F (650°C)

Accuracy A/B Models ± 0.34°F (± 0.19°C) ± 0.34°F (± 0.19°C) ± 0.47°F (± 0.26°C) ± 0.7°F (± 0.39°C)B Models with Probe ± 0.07°F (± 0.04°C) ± 0.07°F (± 0.04°C) ± 0.13°F (± 0.07°C) ± 0.2°F (± 0.11°C)

Stability ± 0.04°F (± 0.02°oC) ± 0.04°F (± 0.02°C) ± 0.04°F (± 0.02°C) ± 0.06°F (± 0.03°C)Resolution (selectable) 1°/ 0.1 / 0.001°F/°CHeating Time (ambient to max) 7 minutes 25 minutesNote Including insertion tubeCooling Time (max to 212°F/100°C) 4 minutes 3 minutes 22 minutes 43 minutesCooling Time (max to 212°F/100°C to 32°F/0°C) 9 minutes 6 minutes N/A N/ATime to Stability 10 minutes - with Visual and Audible IndicationProgrammable Slope Rates 0.1 - 9.9°F/CAutomatic Step Up to 9 Steps with Programmable Dwell TimeDual-Zone ControlInputs (B Models Only) 2, 3, and 4-Wire RTD's, Thermocouples, Thermo Switches, Temperature Transmitters including 24VDC Supply

(Smart Transmitters Included), V, mACommunications RS232 Standard, Synchronizing Output on B ModelsSoftware AmeCal-Temperature Software (Included)Line Voltage 115 (90-127) VAC 45-65 Hz or 230 (180-254) VAC 45-65 Hz, User ChangeableInsertion Tube Multi-Hole Standard (Other Sizes Available)Immersion Depth (including insulation) 6.3 in / 150 mm 6.3 in / 150 mm 5.9 in / 150 mm 5.9 in / 150 mmWell Diameter 1.18 in / 30 mm 0.79 in / 20 mm 1.18 in / 30 mm 1.18 in / 30 mmWeight 26.9 lbs / 12.2 kg 28.9 lbs / 13.1 kg 22.5 lbs / 10.2 kg 26.7 lbs / 12.1 kgDimensions (L x H x W) 13.9 x 6.1 x 14.2 in (352 x 156 x 360 mm)Operating Temperature / Humidity 32 - 104°F (0 - 40°C) / 0 - 90% RHProtection ClassI P-10EMC EN61326-1:1997/A1:1998 EN61010-1:1993/A2:1995Certification NIST Traceable Certification with Data PointsIncluded with Calibrator:AMECAL software, RS232 cable, Manual, Power Cable, Leads, Insertion Tube andTool. AM5720/AM5721 also includes Insulation Cap

• ATC157 Super-Cooler goes to -49°F (-40°C)• B Models Accept Input from Most Instruments• Function Keys for Easy Operation• Programmable Test Parameters• Laboratory Accuracy and Portable

• Dual-zone Heating and Cooling Control• Mains Variance Immunity• Multiple Hole Insertion Tube Standard• Standard RS232

Page 14: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

357Korins Inc. Tel:031-777-1588 Fax:031-777-1587 www.kkkk.com [email protected]

Calibration Equipment

D

Industrial Dry Block Calibrators

Catalog No. Description Bore Insert OD Material PriceAM81125 Dry Block Calibrator, 115V w/ Multi-Hole Insert 3/16, 1/4, (2) 1/8 in 0.75 in Aluminum 4,499.00 AM81126 Dry Block Calibrator, 115V w/ Multi-Hole Insert 3/16, 3/8, (2) 1/4, 1/8 in 1.0 in Delcotal 4,215.00 AM81127 Dry Block Calibrator, 115V with Multi-Hole Insert 3/16, 3/8, 1/4, 1/8 in 1.0 in Brass 4,499.00 AM81128 Carrying case for calibrators 448,000 NISTTA41 NIST Traceable Certificate 312,000NISTTA42 NIST Traceable Certificate 4with Data 472,000

Most insertion tubes include a 4 mm hole for reference probes.Additional insertion tubes available in increments from 1/8 - 7/8 in, 3 - 20 mm, and Imperial or Metric Multi-Hole sizes. Please Inquire.

Safe and reliable with new control circuitry for the upper and lower zones of the blockto allow calibration of larger instruments without the need for a larger calibrator

SPECIFICATIONSAM81125 AM81126 AM81127

Temperature Range Min. @73°F/23°C -19°F (-23°C) 91°F (33°C) 91°F (33°C)Maximum 311°F (155°C) 608°F (320°C) 1202°F (650°C)

Accuracy ± 0.45°F (± 0.25°C) ± 0.54°F (± 0.3°C) ± 0.9°F (± 0.5°C)Stability ± 0.05°F (± 0.03°C) ± 0.05°F (± 0.03°C) ± 0.07°F (± 0.04°C)Resolution (selectable) 1° or 0.1°F/CHeating Time (ambient to max) 14 minutes 7 minutes 25 minutesNote Including insertion tubeCooling Time (max to 212°F/100°C) 4 minutes 30 minutes 56 minutesCooling Time (max to 212°F/100°C to 32°F/0°C) 10 minutes N/A N/ATime to Stability 10 minutes - with Visual and Audible IndicationProgrammable Slope Rates 0.1 - 9.9°F/CAutomatic Step Up to 9 Steps with Programmable Dwell TimeCommunications RS232 StandardSoftware AmeCal-Temperature Software (Included)Line Voltage 140/320 115 (90-127) VAC 45-65 Hz or 230 (180-254) VAC 45-65 Hz, User Changeable

650 115 (90-127) VAC 45-65 Hz or 230 (180-254) VAC 45-65 Hz, User ChangeableInsertion Tube Multi-Hole Standard (Other Sizes Available)Immersion Depth (including insulation on AM81125) 6.3 in / 160 mm 5.9 in / 150 mm 5.9 in / 150 mmWell Diameter 0.79 in / 20 mm 1.18 in / 30 mm 1.18 in / 30 mmWeight 16.8 lbs / 7.6 kg 14.3 lbs / 6.5 kg 18.7 lbs / 8.5 kgDimensions (L x H x W) 9.5 x 5.5 x 14.8 in (241 x 139 x 375 mm)Operating Temperature 32 - 104°F (0 - 40°C)Humidity 0 - 90% RHProtection Class IP-10EMC EN61326-1:1997/A1:1998 EN61010-1:1993/A2:1995Certification NIST Traceable Certification with Data PointsIncluded with Calibrator:AMECAL software, RS232 cable, Manual, Power Cable, Leads, Insertion Tube and Tool. AM81125 also includes Insulation Cap

• Dual-zone heating control (AM81126 andAM81127)

• Improved Block Design and Accuracy• Automated Features• Programmable Minimum/Maximum

• Lightweight, Portable, and Easy-To-Use• Short Heating and Cooling Times• Mains Variance Immunity• Multiple Hole Insertion Tube Standard• Standard RS232

Industrial Temperature CalibratorThe Industrial Temperature Calibrators are easy to use and offer accu-

racies seen in laboratory units. The calibrators are portable and offer theuser the benefit of dual-zone heating well control offsetting the effects ofshorter probes or probes with large heads. This series is available in 3ranges and deep wells are not necessary due to the advanced well controls.The series is programmable and can be used as a stand-alone calibrator toperform complete routines.

Page 15: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

359Korins Inc. Tel:031-777-1588 Fax:031-777-1587 www.kkkk.com [email protected]

Calibration Equipment

D

Compact Dry Block CalibratorsProvides fast, reliable temperature calibration of RTD’s, thermocouples, thermo switches, thermistors, plus other common temperature sensing devices

Catalog No. Model Description Bore Insert OD Material PriceAM140A A Dry Block Calibrator, 115V with Multi-Hole Insert 3/16, 1/4, 1/8 in 0.75 in Aluminum 4,784,000 AM320A A Dry Block Calibrator, 115V with Multi-Hole Insert 3/16, 3/8, 1/4, 1/8 in 1.0 in Delcotal 4,310,400 AM320B B Dry Block Calibrator, Deep Well, 115V, with Std Insert 1/4 in 1.0 in Delcotal 5,438,400 AM650A A Dry Block Calibrator, 115V with Multi-Hole Insert 3/16, 3/8, 1/4, 1/8 in 1.0 in Brass 4,512,000AM650B B Dry Block Calibrator, Deep Well, 115V w/ Std Insert 1/4 in 1.0 in Brass 5,784,000AM1200A A Dry Block Calibrator, 115V with Std Insert 1/4 in 1.6 in Brass 4,995.00 AM2273 Carrying case for calibrators 448,000NISTTA41 NIST Traceable Certificate 328,000NISTTA42 NIST Traceable Certificate with Data 495,000Additional insertion tubes available in increments from 1/8 - 7/8 in, 3 - 20 mm, and Imperial or Metric Multi-Hole sizes. Please Inquire.

• Automated Switch Testing• Programmable Slope Rates• Programmable

Minimum/Maximum• Lightweight, Portable, and

Easy-To-Use

• Short Heating and Cooling Times

• Mains Variance Immunity• Deep Well Units Available• Multiple Hole Insertion Tube

Standard• Standard RS232

SPECIFICATIONSModel AM140A AM320A/B AM650A/B AM1200ATemperature Range Minimum (@73°F/23°C) 1°F (-17°C) 91°F (33°C) 91°F (33°C) 572°F (300°C)Temperature Range Maximum 284°F (140°C) 608°F (320°C) 1202°F (650°C) 2200°F (1205°C)Accuracy ± 0.7°F (± 0.4°C) ± 0.9°F (± 0.5°C) ± 1.1°F (± 0.6°C) ± 3.6°F (± 2.0°C)Stability ± 0.09°F (± 0.05°C) ± 0.18°F (± 0.1°C) ± 0.18°F (± 0.1°C) ± 0.18°F (± 0.1°C)Resolution (selectable) 1° or 0.1° F/CHeating time (ambient to max) 9 minutes 4 minutes/20 minutes 10 minutes/37 minutes 45 minutesNote: Including insertion tubeCooling time (max to 212°F/100C°- to 572°F/300°C for 1200A) 2 minutes 16 minutes/22 minutes 28 minutes/62 minutes 45 minutesCooling time (max to 212°F / 100°C to 32°F / 0° C) 10 minutes N/A N/A N/ATime to Stability (with visual and audible indication) 5 minutes 8 minutes 8 minutes 20 minutesProgrammable Slope Rates 0.1 – 9.9° F/CAutomatic Step Up to 9 steps with programmable dwell timeCommunications RS 232Software AMECAL-Light SoftwareLine Voltage 115 (90-127) VAC 45-65 Hz or 230 (180-254) VAC 45-65 Hz, User ChangeableInsertion Tube AM140A, AM320A, AM650A: Multi-Hole Standard (Other Sizes Available)

AM320B, AM650B, 1200A: 1/4 in Standard (Other sizes available)Immersion Depth 4.5 in 4.3 in / 7.5 in 4.3 in / 7.5 in 4.3 in(including insulation on AM140A) 115 mm 110 mm / 190 mm 110 mm / 190 mm 110 mmWell Diameter 0.75 in 1.0 in 1.0 in 1.6 inWeight 14 lbs 11 lbs / 15 lbs 14 lbs / 23 lbs 26.5 lbs

6.5 kg 5 kg / 6.7 kg 6.4 kg / 10.4 kg 12 kgDimensions L x H x W JF12/JF10/JF14 9.5 x 5.5 x 12.8 in (241 x 139 x 325 mm)

JF14/18 9.5 x 5.5 x 16.1 in (241 x 139 x 408 mm)Operating Temperature 32 – 104° F (0 - 40° C)Humidity 0 – 90% RHProtection Class IP-10EMC EN 61326-1:1997/A1:1998/ EN61010-1:1993/A2:1995Certification NIST Traceable Certification with Data Points

Compact Temperature CalibratorThe Compact Temperature Calibrators

are easy to use and extremely portable.These calibrators are lightweight and yethighly accurate. The units are availablein three temperature ranges and differentwell depths. The dry-blocks are versatile,portable, and highly accurate. This seriesof temperature calibrators offers featuresincluding programmable test routines,variable slope rates, and an easy-to-readdisplay.

Page 16: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

Korins Inc. Tel:031-777-1588 Fax:031-777-1587 www.kkkk.com [email protected]

D

Calib

ratio

n Eq

uipm

ent

354

Field Temperature Dry-Well CalibratorsThese new units beat every other

comparable dry-well in the industry inperformance, size, weight, conve-nience, ease of calibration, softwareand price. In addition, the heating andcooling rate of each of these dry-wellsis adjustable from the front panel,thermal switches can be checked bythese units for actuation testing andmultiple-hole inserts are available fora variety of probe sizes.

SPECIFICATIONSModel Series 9140 (shown left) Series 9141 (shown right)Range 95°F to 662°F (35°C to 350°C) 122°F to 1202°F (50°C to 650°C)Accuracy ± 0.9°F (± 0.5°C); accuracy in insert holes greater 122°F to 752°F (50°C to 400°C):

than 1⁄4" will be at ± 1.8°F (± 1°C) ± 0.9°F (± 0.5°C), 752°F to 1202°F (400°C to 650°C): ± 1.8°F (± 1°C), holes greater than 1/4” (6.35 mm): ± 3.6°F (± 2°C)

Stability ± 0.03°C @ 50°C; ± 0.05°C @ 100°C; ± 0.2°C @ 500°C;± 0.05°C @ 350°C ± 0.12°C @ 650°C

Uniformity ± 0.72°F (± 0.4°C) typical ± 0.18°F (± 0.1°C) 122°F to 752°F (50°C to 400°C): ± 0.72°F (± 0.1°C) typical,with similarly sized wells ± 0.9°F (± 0.5°C) with similarly sized wells above 752°F (400°C)

Heating Times 12 minutes from ambient to 662°F (350°C) 12 minutes from ambient to 1202°F (650°C)Cooling Times 15 minutes from 662°F to 212°F (350°C to 100°C) 25 minutes from 1202°F to 212°F (650°C to 100°C)Stabilization Time 7 minutesImmersion Depth 4.875 inches (124 mm)Computer Interface RS-232 included with free Windows®-based software Power 115 VAC (± 10%), 50/60 Hz and 230 VAC (± 10%), 50/60 Hz switchableSize 6" W x 3.375" H X 7.75" D (152 x 86 x 197 mm) 4.5" W x 9" H x 7" D (114 x 229 x 178 mm)Weight 6 lb. (2.7 kg) 8 lb. (3.6 kg)Certification Includes 7-point, NIST-traceable certificate of Includes 7-point, NIST-traceable certificate of

calibration with data at the following points: calibration with data at the following points:50°C, 100°C, 150°C, 200°C, 250°C, 300°C and 350°C 100°C, 200°C, 300°C, 400°C, 500°C and 600°C

Catalog No. Description PriceHR9140A Dry-Well Calibrator* (A insert included) 4,144,000HR9140B Dry-Well Calibrator (B insert included) 4,144,000HR9140C Dry-Well Calibrator (C insert included) 4,144,000HR9103 Dry-Well Calibrator (A insert included) 6,232,000HR31401 Insert, blank 320,000HR31402 Insert A 320,000HR31403 Insert B 320,000HR31404 Insert C 320,000HR9308 Rugged Carrying Case 208,000HR9141A Dry-Well Calibrator (A insert included) 5,936,000HR9141B Dry-Well Calibrator (B insert included) 5,936,000HR9141C Dry-Well Calibrator (C insert included) 5,936,000HR31411 Insert, blank 616,000HR31412 Insert A 616,000HR31413 Insert B 616,000HR31414 Insert C 616,000HR9309 Rugged Carrying Case 664,000NISTTA41 NIST Traceable Certificate 312,000NISTTA42 NIST Traceable Certificate with Data 472,000

• Accuracy to ± 0.5°C• RS-232 and Windows® software included• Easy to recalibrate• Less than eight pounds

Choose one of three removeable inserts sized from 1/16" to 1/2"diameter. Insert A handles a full range of probe sizes with a singlewell of each size. Insert B features two wells each of 3/8", 1/4" and3/16" in diameter for doing comparison calibrations, and insert Chas six 1/4" diameter wells for multiple probe calibrations

SPECIFICATIONS — Series 9103 (shown center)Range –25 to 140°C (–13 to 284°F), in ambient of 23°C

± 3°C (Can do lower depending on ambient.)Accuracy ± 0.25°C Stability ± 0.02°C @ –25°C, ± 0.04°C @ 140°CUniformity ± 0.3°C typical (± 0.1 with similar size wells)Resolution 0.1°Display Scale °F or °C, switchableHeating Time 18 minutes, ambient to 140°CCooling Time 20 minutes, ambient to –25°CStabilization Time 7 minutesInserts (included) Insert A: 1⁄2", 3⁄8", 1⁄4", 3⁄16", 1⁄8" and 1⁄16" holesDepth 4.875 inches (124 mm) immersionComputer Interface RS-232 includedSize 10.25" H x 5.63" W x 9.63" D (26.1 x 14.3 x 24.5 cm)Weight 12.5 lb. (5.7 kg)Certification 7-point NIST-traceable certificate of calibration included

*

Page 17: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

355Korins Inc. Tel:031-777-1588 Fax:031-777-1587 www.kkkk.com [email protected]

Calibration Equipment

D

1200°C Calibration Furnace

Catalog No. Description PriceHR91502 Thermocouple Furnace, 1200° with A Insert 8,960,000HR91503 Thermocouple Furnace, 1200° with B Insert 8,960,000HR91504 Thermocouple Furnace, 1200° with C Insert 8,960,000

AccessoriesHR9315 Rugged carrying case 744,000NISTTA41 NIST Traceable Certificate 312,000NISTTA42 NIST Traceable Certificate with Data 472,000

• Low cost makes thermocouple testing affordable• Rapid heating to 1200°C saves time• Compatible with Calibration software for

completely automated testing• Multi-hole inserts allow comparison calibrations accurate to ± 1°C• Three standard inserts to choose from custom inserts available

SPECIFICATIONSTemperature Range 150°C to 1200°C 302°F to 2192°FDisplay Resolution 0.1°C/F below1000°C/F 1°C/F above 1000°C/FStability ± 0.5°C (± 0.9°C) at 1200°CDisplay Accuracy ± 5°C (± 9°F)Heating Time to Max. 35 minutesCooling Time to Min. 140 minutesWell Diameter 1.25" (32 mm)Well Depth 5.5" (4" in removable insert, plus 1.5" in

insulator) (102 mm)Power 115/230 VAC (± 10%)Size 305mm H x 191 mm W x 280mm D

12" x 7.5" x 11"Weight 28 pounds (13kg)

If you work with high-temperature thermocou-ples and you'd rather test them than throw themout, but you haven't found a calibration instru-ment that checks them economically, now youhave a solution.

This Calibrator delivers all the benefits tomake verifying your thermocouples productiveand effective.

The unit’s temperature display and built-intype S thermocouple are system calibrated in ourlab for display accuracy. of ±5°C (7.2°F) over theentire range 1200°C (2192°F). Each unit includesa NIST traceable certificate with data at sevenpoints between 150°C and 1200°C.

For comparison work, stability is better than±0.5°C (0.9°F) at 1200°C and even better at lowertemperatures. Hole-to-hole gradients are also lessthan ±0.5°C at maximum temperature. Therefore,with a good reference thermometer and carefulcomparison techniques, your calibration uncer-tainties can be less than 1°C.

A wide variety of inserts is available to maxi-mize productivity and enable comparison work.Thermocouples from 1/16" to 1/2" (1.6 to 12.7 mm)in diameter can be used, depending on which ofour standard inserts you choose. Each insert ac-cepts as many as six probes. Custom inserts arealso available.

Each furnace comes with an RS-232 interface -it software which lets you control the unit from aWindows® environment. For maximum productivi-ty, the unit can be combined with a Hart referencethermometer and our Calibration Software to fullyautomate thermocouple testing. The softwarereads all types of temperature sensors, controlsheat sources and creates calibration reports thatcomply with ANSI/NCSL Z540-1.

For use in the field, the unit includes importantfeatures for on-site calibrations. At only 28 pounds(13kg), it goes anywhere you need it to. This fur-nace heats to maximum temperatures in just overhalf-hour.

Page 18: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

353Korins Inc. Tel:031-777-1588 Fax:031-777-1587 www.kkkk.com [email protected]

Calibration Equipment

D

Metrology Wells

Catalog No. Description PriceHR9170A Metrology Well, -–45°C to 140°C, with INSX 11,600,000HR9170AR Metrology Well, -–45°C to 140°C, with INSX, with built-in reference 13,200,000HR9171A Metrology Well, –30°C to 155°C, with INSX 10,400,0000HR9171AR Metrology Well, –30°C to 155°C, with INSX, with built-in reference 12,000,000HR9172A Metrology Well, 35°C to 425°C, with INSX 8,000,000HR9172AR Metrology Well, –30°C to 155°C, with INSX, with built-in reference 9,600,000HR9173A Metrology Well, 50°C to 700°C, with INSX 10,000,000HR9173AR Metrology Well, 50°C to 700°C, with INSX, with built-in reference 11,600,000HR9170CASE Carrying case, Metrology Wells (Models 9170-3) 880,000Each Unit Includes: selected insert (insert A, B, or C), insert removal tool, report of calibration, RS-232 cable, 9930 Interface-it software, and a user manual.

Metrology Wells deliver lab accuracy anywhere!

Hart Scientific has combined bath-level performance withdry-well functionality and legitimate reference thermometryto create Metrology Wells. New analog and digital controltechniques provide stability as good as ±0.005°C. With dual-zone control, axial (or “vertical”) uniformity is as good as±0.02°C over a 2.4" (60 mm) zone.

This optionally built-in input accepts 100-, 25-, and 10-ohm PRTs and reads thermometer probes accurately from±0.006°C at 0°C to ±0.027°C at 661°C, not including errorsfrom the probe. A large LCD display, numeric keypad, andon-screen menus make use of Metrology Wells simple and in-tuitive. The display shows the block temperature, built-inreference thermometer temperature, cutout temperature,stability criteria, and ramp rate.

• Best performing industrial heat sources (accuracy, stability, uniformity)in the world

• Immersion depth to 8" (203 mm)• Optional ITS-90 reference input reads PRTs to ± 0.006°C• Temperature range from –45°C to 700°C

SPECIFICATIONSHR9170 HR9171 HR9172 HR9173

Range (at 23°C ambient) –45°C to 140°C (–49°F to 284°F) –30°C to 155°C (–22°F to 311°F) 35°C to 425°C (95°F to 797°F) 50°C to 700°C† (122°F to 1292°F)Display Accuracy ± 0.1°C full range ± 0.1°C to 100°C ± 0.2°C to 425°C

± 0.15°C to 225°C ± 0.25°C to 660°C± 0.2°C to 425°C

Stability ± 0.005°C full range ± 0.005°C to 100°C ± 0.005°C to 100°C± 0.008°C to 225°C ± 0.01°C to 425°C± 0.01°C to 425°C ± 0.03°C to 700°C

Axial Uniformity (60 mm) ± 0.1°C: –45°C to –35°C ± 0.04°C: –30°C to 0°C ± 0.05°C to 100°C ± 0.1°C to 100°C± 0.04°C: –35°C to 0°C ± 0.02°C: 0°C to 50°C ± 0.1°C to 225°C ± 0.5°C to 425°C± 0.02°C: 0°C to 50°C ± 0.07°C to155°C ± 0.2°C to 425°C ± 0.4°C to 700°C± 0.07°C to 140°C

Radial Uniformity ± 0.01°C full range ± 0.01°C to 100°C ± 0.01°C to 100°C± 0.02°C to 225°C ± 0.025°C to 425°C± 0.025°C to 425°C ± 0.04°C to 700°C

Loading Effect ± 0.02°C: –45°C to –35°C ± 0.005°C to 0°C ± 0.01°C full range ± 0.02°C to 425°C(with reference thermometer) ± 0.005°C: –35°C to 0°C ± 0.02°C to 155°C ± 0.04°C to 700°C

± 0.01°C to 140°CHysteresis ± 0.025°C ± 0.04°C ± 0.07°CWell Depth 160 mm (6.3") 203 mm (8")Key Pad Ten key with decimal and +/- button. Function keys, menu key, and °C/°F button.Size (HWD) 366 x 203 x 323 mm (14.4" x 8” x 12.7")Weight 15 kg (33 lb) 15 kg (33 lb) 13.2 kg (29 lb) 15 kg (33 lb)Temperature Accuracy 10Ω PRTs: 25Ω and 100Ω PRTs:(Does not include probe ± 0.013°C at 0°C ± 0.007°C at –45°Cuncertainty) ± 0.013°C at 50°C ± 0.008°C at 0°C

± 0.014°C at 155°C ± 0.011°C at 155°C± 0.014°C at 225°C ± 0.013°C at 225°C± 0.019°C at 425°C ± 0.019°C at 425°C± 0.028°C at 700°C ± 0.027°C at 661°C

Resistance Resolution 0Ω to 20Ω: 0.0001Ω20Ω to 400Ω: 0.001Ω

Probe Connection 4-wire with shield, 5-pin DIN connectorRecommended Probes HR562615D or HR562815DCalibrated to 660°C; Reference thermometer recommended at higher temperatures.

Page 19: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

351Korins Inc. Tel:031-777-1588 Fax:031-777-15 87 www.kkkk.com [email protected]

Calibration Equipment

D

Ice Point & Uniform Temperature ReferencesObtaining high-accuracy measurements from

thermocouples requires instrumentation de-signed to minimize errors. Thermocouple confor-mity, the cold junction and its reference, the A/Dconverter and other analog system electronics allcontribute to the overall system error. While thecold junction (termination of thermocouple tocopper) can contribute significantly to system error, this error can be minimized with a high-accuracy temperature reference.

• Fast Turnaround Time

• Free Nationwide On-Site Service

• Free Pick-Up and Delivery Service

• Mobile Calibration Laboratory Service

We Offer On-Site Calibration ServicesWe Offer On-Site Calibration Services

Catalog No. Description PriceGE0280 Uniform Temperature Reference; 32 channels 3,120,000GE0290 Uniform Temperature Reference; 48 channels 3,120,000GE0360 UTR; Calibrated Resistance Temperature Detector 992,000GE0370 UTR; Calibrated 100Ω, 4-wire Platinum Element 488,000GE0240 Automatic Ice Point Bath 4,608,000GE0262 Ice Point Reference; 24 channels *N1 6,384,000GE0264 Ice Point Reference; 50 channels *N1 8,856,000GE0265 Ice Point Reference; 75 channels *N1 10,072,000*N1 Note: Specify thermocouple types

Uniform Temperature References

The GE Kaye Uniform Temperature References (UTRs) provide coldjunction temperature measurement for up to 64 thermocouples withtwice the accuracy of conventional models. This high level of accuracyis achieved through remote monitoring via a NIST-traceable RTD,which automatically performs compensation calculations. The UTRsare passive mechanical devices requiring no external power.

• Operates in temperature extremes • Easily reconfigured for different thermocouple types • Can be installed near test article in the test environment

Ice Point References

GE Kaye's Ice Point References provide the highest level of accuracyin automatic referencing - zero long-term drift maintaining referencetemperature at 0°C. Ice Point References are available in rack-mountor portable configurations with capacity for up to 75 thermocouples.

• Operates from 0 to 40°C • Negligible effect from rapid changes in ambient • Convenient for more permanent installations • Limited to stable areas of vibration and ambient, e.g., control room

Page 20: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

347Korins Inc. Tel:031-777-1588 Fax:031-777-1587 www.kkkk.com [email protected]

Calibration Equipment

D

Liquid Temperature Control

Catalog No. Model Description PricePS072718 Model 9712 Refrigerating/Heating Circulator (120V, 60Hz, 14A) 6,918,400PS072720 Model 9712 Refrigerating/Heating Circulator (240V, 50Hz, 9.9A) 6,753,600PS072531 Model 9106 Refrigerating/Heating Circulator (120V, 60Hz, 12A) 3,473,600PS072535 Model 9106 Refrigerating/Heating Circulator (240V, 50Hz, 9.9A) 3,428,800PS052701 Model 7306 Immersion Circulator (120V, 50/60Hz, 11A) 2,048,000PS052741 Model 7306 Immersion Circulator (240V, 50/60Hz, 7.5A) 2,040,000PS040512 Calibration Reservoir for Model 9712. Includes reservoir lids capable of holding up to 2,419,200

30 thermometers plus required hoses/fittings. (4.75 liter capacity; 18 inch working depth)NISTCA35 NIST Traceable Certificate 320,000NISTCA35 NIST Traceable Certificate with Data 472,000

Circulating Baths and Immersion Circulators

SPECIFICATIONSModel 9712 Model 9106 Model 7306

Controller Programmable; capable of storing ten Standard with 3 user-defined Standard with 3 user-defined temperature50 step time/temperature programs temperature pre-set buttons pre-set buttons

TemperatureRange -40° to 200°C -20° to 150°C Ambient + 5° to 150°CStability ± 0.01°C ± 0.05°C ± 0.05°CReadout Multi-line LCD LED LEDReadout Accuracy ± 0.25°C ± 0.5°C ± 0.5°CDimensions (l x w x h)Overall 17 x 15.5 x 24.75 in. 15.75 x 8.25 x 22.5 in. 5.75 x 4.625 x 12.25 in.Working Access 6 x 11 x 5.5 in. 5.25 x 5.25 x 5.5 in. n/aImmersion Depth n/a n/a 3 in. (Min.); 7 in. (Max.)Pump Type Variable speed 2-speed simplex 2-speed simplexPressure Flow Rate up to 30 lpm/5.0 PSI for 60 Hz and 9 or 15 lpm 9 or 15 lpm

22 LPM/3.4 PSI for 50HzHeater 1100 watts (60 Hz) 1100 watts (60 Hz) 1100 watts (60 Hz)

2200 watts (50 Hz) 1600 watts (50 Hz) 1600 watts (50 Hz)Warranty 2 years parts, 1 year labor 2 years parts, 1 year labor 2 years parts, 1 year labor

PolyScience Circulating Baths and ImmersionCirculators combine excellent temperature controlwith operational simplicity. Suitable for a wide va-riety of applications, they feature highly accuratemicroprocessor-based temperature controllers, in-tegral over-temperature and low-liquid level pro-tection, and exceptionally quiet operation.

Model 9712 Heating/Refrigerating Circulator• Sophisticated programmable controller for time/temperature profiling• -40° to 200°C temperature range• ± 0.01°C temperature stability• 13 liter reservoir• User-adjustable high and low temperature alarms• Variable speed pressure/suction pump• Remote control and datalogging capability• Optional thermometry calibration reservoir available

Model 9106 Heating/Refrigerating Circulator• PID controller with three user-defined temperature preset buttons for

rapid set point changes• -20° to 150°C temperature range• ± 0.05°C temperature stability• 6 liter reservoir• Small footprint – less than 1 sq.ft.• 2-speed pressure pump

Model 7306 Immersion Circulator• PID controller with three user-defined temperature preset buttons for

rapid set point changes• Ambient + 5° to 150°C temperature range• ± 0.05°C temperature stability• 2-speed pressure pump• May be clamped to tank side or mounted to a standard lab stand

Page 21: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

Korins Inc. Tel: 031-777-1588 Fax:031-777-1587 Order Online www.kkkk.com [email protected]

J

Pres

sure

Precision Barometric Indicator

Catalog No. Description PriceGE142 DPI 142 Precision Barometric Indicator 3,032,000GE142ABC DPI 142 with IEEE488 Communications, Analog Output and Panel Mount Kit 4,168,000Included Accessories: User handbook,Calibration certificate traceable to international standards, AC/DC power adaptor 90 to 264VAC, 45 to 65 Hz

Suitable for any data logging or integrated information system

SPECIFICATIONSFull Barometric Range 10.9 – 16.7 PSIAOptional Ranges 50 PSIAMaximum Pressure 58 PSIA Precision Typically 0.01% full scale includes non-linearity, hysteresis, repeatability and temperature effects over 10°C to 40°CLong-term Stability Better than 100ppm (0.01%full scale) per yearPower Supply 11V to 26V AC or DC – 10VA via 2.1mm JackEnvironmental Temperature Operating: 50°C to 500°C / calibrated: 230°C / Storage: -200° to 600°

• High-contrast, backlit LCD• Full six-digit scaling with choice of 24 user-

selectable pressure units • Altitude display in feet and meters• Programmable analog output• Easy-to-use software menus accessed via

front panel push buttons• Display available in 8 different languages• Standard RS232 output

Options— IEEE 488 digital communications— Analog output (select 0to10V, 0to5V,

-5to+5V, 0/4to20mA)— Panel mounting kit

This Barometric Indicator is ideal for use as ageneral barometric reference or as acalibration/service laboratory standard. It is bestsuited for high precision measurement of baro-metric and low absolute pressures. High accuracyand long term stability improve productivity andreduce cost of ownership.

Fast, Friendly Service.Fast, Friendly Service.

Need MoreInformation about

a product?

Ask for TechnicalService.

Need MoreInformation about

a product?

Ask for TechnicalService.

Page 22: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

827Korins Inc. Tel:031-777-1588 Fax:031-777-1587 Order Online: www.kkkk.com [email protected]

Pressure

J

Digital Pressure Test Gauge

Catalog No. Description PriceML1919157 BetaGauge PI, 15 PSI 1,160,000ML1919158 BetaGauge PI, 30 PSI 1,160,000ML1919159 BetaGauge PI, 100 PSI 1,160,000ML1919160 BetaGauge PI, 500 PSI 1,160,000ML1919178 BetaGauge PI, 1000 PSI 1,160,000ML1919161 BetaGauge PI, 3000 PSI 1,160,000ML1919162 BetaGauge PI, 5000 PSI 1,160,000ML1919163 BetaGauge PI, 10000 PSI 1,160,000ML1919219 BetaGauge PI, 15 PSI Kit with pump, test hose, rubber boot & carrying case 2,232,000ML1919220 BetaGauge PI, 30 PSI Kit with pump, test hose, rubber boot & carrying case 2,232,000ML1919221 BetaGauge PI, 100 PSI Kit with pump, test hose, rubber boot & carrying case 2,232,000ML1919222 BetaGauge PI, 500 PSI Kit with pump, test hose, rubber boot & carrying case 2,232,000ML1919223 BetaGauge PI, 1000 PSI Kit with pump, test hose, rubber boot & carrying case 2,552,000ML1919224 BetaGauge P, 3000 PSI Kit with pump, test hose, rubber boot & carrying case 2,552,0005000 and 10000 PSI Kits available – Please inquireRear Mount and 24V external power versions available - Please inquire.

• Very high accuracy compared to analog test gauges;±0.05% F. S.; temperature compensated

• Temperature compensated accuracy over 0 to 50 °C • Eight (8) standard pressure ranges • Displays in 18 standard or fully custom engineering

units • Displays ambient temperature in °C or °F • Large, back-lit, 5-1/2 digit display with 0.65" high dig-

its and 20 segment bar graph • Rugged stainless steel case meets NEMA 4/IP65 • Password-protected “through the keypad” calibration • MIN/MAX recall • Adjustable TARE zeros large system offsets • User-configurable sample rate maximizes measure-

ment performance and battery life • User-configurable damping smoothes readings from

pulsating/plant air sources • Auto Shut-off for extended battery life • Low battery indicator • CSA intrinsically safe, Class 1, Div. 2• CE approved • Available with optional sanitary seal • Available with optional 24 V external power input • Available with optional rubber boot • Also available as a kit (with pump)

The BetaGauge P.I. DigitalPressure Test Gauge takes the con-cept of an analog Test Gauge, andbrings it to a new level, as only BetaCalibrators can do. The BetaGaugeP.I. combines the accuracy of digitaltechnology with the simplicity of ananalog gauge, and achieves perfor-mance, ease-of-use, and a feature setunmatched in the pressure measure-ment world.

SPECIFICATIONSInput Ranges 15 psi / 1 BAR, 30 psi / 2 BAR, 100 psi / 7 BAR

500 psi / 30 BAR, 1,000 psi / 70 BAR 3,000 psi / 200 BAR, 5,000 psi / 300 BAR 10,000 psi / 700 BAR

Accuracy ± 0.05% FS Positive Pressure ± 0.25% FS Vacuum/500 psi and below

Temperature Compensation 0 °C to + 50 °C (32 °F to +122 °F) to rated accuracy Standard Engineering Units PSI, Bar, Kg/cm2, inH2O, ft H2O, cmH2O, mH2O, Kpa,

mBAR, inHg, mmHg, TORR Media Compatibility Liquids and gases compatible with 316 stainless steel Environmental Operating Temperature: -10 to +55 °C Storage -20 to +70 °C (-4 to +158 °F) Dimensions 4.375 x 5.0 x 1.50”Input Port 1/4" male NPT Display 5 digits, 0.65” (16.53mm) height Bar Graph 0 to 100% in 20 segments Power Battery: three (3) size AA alkaline batteries

Battery Life: 1,500 hours without backlight 2,000 hours at slow sample rate. Battery life can be displayed on bar graph to indicate the amount of time left Low Battery Indictor: Displayed icon near the end of battery life

Includes Manual, Batteries

Page 23: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

Korins Inc. Tel:031-777-1588 Fax:031-777-1587 www.kkkk.com [email protected]

J

Pres

sure

826

Crystal Digital Pressure Gauge

Catalog No. Description Price Catalog No. Pricewithout software with DataLoggerXP SoftwareCL15PSIXP2I 15 PSI Standard Engineering Unit 1,272,000 CL15PSIXP2ID 2,064,000CL30PSIXP2I 30 PSI Standard Engineering Unit 1,272,000 CL30PSIXP2ID 2,064,000CL100PSIXP2I 100 PSI Standard Engineering Unit 1,112,000 CL100PSIXP2ID 1,904,000CL300PSIXP2I 300 PSI Standard Engineering Unit 1,112,000 CL300PSIXP2ID 1,904,000CL500PSIXP2I 500 PSI Standard Engineering Unit 1,272,000 CL500PSIXP2ID 2,064,000CL1KPSIXP2I 1000 PSI Standard Engineering Unit 1,272,000 CL1KPSIXP2ID 2,064,000CLSKPSIXP2I 2000 PSI Standard Engineering Unit 1,272,000 CLSKPSIXP2ID 2,064,000CL3KPSIXP2I 3000 PSI Standard Engineering Unit 1,272,000 CL3KPSIXP2ID 2,064,000CL5KPSIXP2I 5000 PSI Standard Engineering Unit 1,352,000 CL5KPSIXP2ID 2,144,000CL10KPSIXP2I 10000 PSI Standard Engineering Unit 1,512,000 CL10KPSIXP2ID 2,304,000CL100KPAXP2I 100 kPa SI Unit w/kpa and/or Mpa, Bar and/or mBar only 1,272,000 CL100KPAXP2ID 2,064,000CL200KPAXP2I 200 kPa SI Unit w/kpa and/or Mpa, Bar and/or mBar only 1,272,000 CL200KPAXP2ID 2,064,000CL700KPAXP2I 700 kPa SI Unit w/kpa and/or Mpa, Bar and/or mBar only 1,112,000 CL700KPAXP2ID 1,904,000CL2KKPAXP2I 2000 kPa SI Unit w/kpa and/or Mpa, Bar and/or mBar only 1,112,000 CL2KKPAXP2ID 1,904,000CL3KKPAXP2I 3000 kPa SI Unit w/kpa and/or Mpa, Bar and/or mBar only 1,272,000 CL3KKPAXP2ID 2,064,000CL7KKPAXP2I 7000 kPa SI Unit w/kpa and/or Mpa, Bar and/or mBar only 1,272,000 CL7KKPAXP2ID 2,064,000CL14KKPAXP2I 14000 kPa SI Unit w/kpa and/or Mpa, Bar and/or mBar only 1,272,000 CL14KKPAXP2ID 2,064,000CL20KKPAXP2I 20000 kPa SI Unit w/kpa and/or Mpa, Bar and/or mBar only 1,272,000 CL20KKPAXP2ID 2,064,000CL30KKPAXP2I 30000 kPa SI Unit w/kpa and/or Mpa, Bar and/or mBar only 1,352,000 CL30KKPAXP2ID 2,144,000CL70KKPAXP2I 70000 kPa SI Unit w/kpa and/or Mpa, Bar and/or mBar only 1,512,000 CL70KKPAXP2ID 2,304,000Accessories ModelCL2400 DB9 RS-232 Cable 80,000CLDATALOGGERXP — DataLoggerXP Software 792,000CLRP RP Rear Port 72,000 CLF4 F4 4-1/2" panel munt flange (w/rear port) 152,000 CLDD DD Dual Line Display 160,000 DL0 O Gauge cleaned for oxygen service 320,000 NISTPR5 — NIST Traceable Certificate 136,000 NISTPR6 NIST Traceable Certificate with Data 208,000

SPECIFICATIONSAccuracy ±(0.1% of reading) from 20% – 100% of full scale

±(0.02% of Full Scale) from 0 – 20% of Full ScaleVacuum (300 PSI ranges and lower) ±(0.25% of Full Scale) where FS = -14.5 PSI

Temperature Operating and Compensated: -10°C to 50°C (14°F to 122°F)Storage: -4°C to 70°C (-4°F to 158°F)

Display 5 Full (seven segment) digits, 0.65" high characters, Update - 3 readings per secondDual Display: 0.55" high characters

General Pressure Connection: 1/4" NPT Male, bottom connectionSize: 5.8 x 4.4 x 1.3 inchesPower: 3 size AA batteries with typical 1500 hours life. Low battery indicator

Software Labview DriversConfigXPSerialDL Data Logging (free email distribution)

The DataLogger XP software and an XP2i digital test gaugeform an integrated data logging solution. While the XP2i per-forms all of the actual data collection, DataLoggerXP handles thetransfer and saving of that data to a computer’s hard drive. Oncemeasurements have been collected and transferred,DataLoggerXP can save the data files directly into a spreadsheet.

• Collect up to 3,000 data points• Change data collection parameters from either a computer or the keypad of an XP2i• Start and stop multiple collection runs from the XP2i keypad• Switch an XP2i from standard to DataLogger mode in minutes• When ordered for a new gauge, the datalogging package includes CD, Quick Setup “luggage tag” and

manual

DataLoggerXP Data-Logging Solution

Page 24: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

Korins Inc. Tel:031-777-1588 Fax:031-777-1587 Order Online www.kkkk.com [email protected]

D

Calib

ratio

n Eq

uipm

ent

Portable Pressure CalibratorsPneumatic and Hydraulic Differential

• Ranges vac to 10,000 psi, multi-rangeable

• Accuracy from ± 0.025% Full Scale• Fully documenting with RS 232

(DPI615)• Generates Pressure and Vacuum• Dual Readout: Input and output

Pneumatic Calibrator • Pressure/vacuum pump -22 inHg

to 300 psi capability• Volume adjuster Fine pressure

adjustment• Release valve Vent and controlled

release• Pressure port - 1/8 NPT (female)• Media - Dry, non-corrosive, non-

conductive gasses compatible with316 stainless steel, HastelloyC276, BUNA-N and nylon

Hydraulic Calibrator • Priming pump - Feeds from

external source• Shut-off valve - Open for system

priming• Screw press - 0 to 6000 psi

capability• Pressure port - 1/8 NPT (female)• Media - Demineralized water

and most hydraulic oils

Pneumatic Calibrator Hydraulic Calibrator Documenting Calibrator

Electrical InputsInput Range Accuracy Resolution RemarksVoltage* ± 50Vd.c. ± 0.05%Rdg. ± 0.004%FS 100µV max Autoranging, >10MW

(± 30Vdc IS version)Current* ± 55mA ± 0.05%Rdg. ± 0.004%FS 0.001mA 10ohm, 50V max.Temperature 15° to 105°F ± 2°F 0.2°F Local ambientSwitch Open/Closed — — 5mA whettingElectrical OutputsOutput Range Accuracy Resolution RemarksVoltage 10Vd.c. ± 0.1% — Max. load 10mA

24Vd.c. ± 5% Max. load 26mACurrent* 0 to 24mA ± 0.05%Rdg. ± 0.1%F.S. 0.001mA —*Temperature coefficient ± 0.004% reading/°F w.r.t. 68°F.Special FeaturesPressure units 25 scale units plus one user defined.mA step Continuous cycle at 10 sec intervals.Function mA Output4 to 20mA linear 4 8 12 16 20 — —0 to 20mA linear 0 5 10 15 20 — —4 to 20mA flow 4 5 8 13 20 — —0 to 20mA flow 0 1.25 5 11.25 204 to 20mA valve 3.8 4 4.2 12 19 20 21mA ramp Continuous cycle with configurable end values and 60 sec travel time.Data log Multi-parameter with internal memory for 10,000 values. Variable sample period or log on key press.

(615: log on key press for calibration results)Snapshot Paperless notepad. Stores up to 20 complete displays.Computer interface DPI 615 Bidirectional for downloading procedures and uploading results.Process functions Tare, max/min, filter, flow, % span.Language English, French, German, Italian, Portuguese and Spanish.Power management Auto power OFF, auto backlight OFF, battery low indicator and status on key press.DisplayPanel 2.36 x 2.36 inch graphic LCD with backlight.Readout ± 99999 capability, 2 readings per second.EnvironmentalOperating Temperature 15° to 120°FCalibrated Temperature 15° to 105°FHumidity 0 to 90%, non-condensing.Sealing Generally to NEMA 12 (IP54)Conformity EN61010, EN50081-1, EN50082-1, CE marked.Physical 7.7 lb, 11.8 x 6.7 x 5.5 inchesPower supply 6 x 1.5 V 'C' cells, alkaline (up to 65 hours nominal use at 68°F rechargeable battery pack and charger

are supplied as standard (20 hours nominal use).

Page 25: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

307Korins Inc. Tel:031-777-1588 Fax:031-777-1587 Order Online www.kkkkk.com [email protected]

Calibration Equipment

D

Portable Pressure Calibrator This self-contained, battery powered package contains a pressure generator, fine pressure control, device energiz-

ing and output measurement capabilities, as well as facilities for 4-20 mA loop testing and data storage. The ruggeddesign sealed generally to NEMA 12 (IP54) is ergonomically designed such that the pressure pump can be operatedand test leads connected without compromising the visibility of the large dual parameter display. The mA step andramp outputs and built-in continuity tester extend the capabilities to include the commissioning and maintenance ofcontrol loops.

Fully documenting version The documenting version provides error analysis for field reporting of calibration errors and pass/fail status. In

addition, procedures downloaded from a PC automatically configure the DR639123 & DR639124 to pre-defined calibration and test routines.

Catalog No. Description PriceDPI 610 Documenting CalibratorsIncludes pressure/vacuum pump, volume adjuster, vent valve, carrying case, rechargeable battery pack and charger, 25 user selectable scales as standard, calibration certificate, manual and electrical leads.DR639108 Portable Digital Calibrator, 5 psi 4,496,000 DR639110 Portable Digital Calibrator, 30 psi 4,496,000DR639109 Portable Digital Calibrator, 100 psi 4,496,000DR639111 Portable Digital Calibrator, 300 psi 4,496,000DR639113 High Pressure Portable Digital Calibrator, 3000 psi 6,320,000DR6391131 High Pressure Portable Digital Calibrator, 5000 psi 6,320,000DR6391132 High Pressure Portable Digital Calibrator, 6000 psi 6,320,000DPI 615 Documenting CalibratorsIncludes preesure/vacuum pump, volume adjuster, vent valve, carrying case, rechargeable battery pack and charger, 25 user selectable scales as standard, calibration certificate, manual and electrical leads.DR639125 Portable Digital Documenting Calibrator, 5 psi 5,540,000DR639127 Portable Digital Documenting Calibrator, 30 psi 5,540,000DR639126 Portable Digital Documenting Calibrator, 100 psi 5,540,000DR639123 Portable Digital Documenting Calibrator, 300 psi 5,540,000DR639124 High Pressure Portable Digital Documenting Calibrator, 3000 psi 7,784,000DR6391241 High Pressure Portable Digital Documenting Calibrator, 5000 psi 7,784,000DR6391242 High Pressure Portable Digital Documenting Calibrator, 6000 psi 7,784,000Standard OptionsDR191126 NICAD Battery Pack 104,000DR191129 Universal Charger for 110v or 220v 136,000Remote Pressure SensorsDR639115 1 psi gauge 1,720,000DR639116 5 psi gauge 1,376,000DR6391161 10 psi gauge 1,376,000DR6391162 30 psi absolute 1,376,000DR6391163 100 psi gauge 1,376,000DR6391164 300 psi gauge 1,376,000DR6391165 500 psi gauge 1,376,000DR6391166 1,000 psi gauge 1,720,000DR6391167 2,000 psi gauge 1,720,000DR6391168 5,000 psi gauge 1,720,000DR639117 10,000 psi gauge 1,720,000DR639118 1 psi differential 2,072,000DR639119 5 psi differential 1,720,000*Note A minimum of one mating cable DR639121 is required when ordering remote pressure sensorsDR639120 Low Pressure Remote Sensor 2,072,000

Specify Range: +/-1,+/-5,+/-10,+/-20,+/-30, and +/-60 in. H2OAccessoriesDR639121 Mating Cable 152,000DR6002 Dirt Moisture Trap 320,000DR781013 "Intecal for Industry" Software 1,280,000DR639211 Spare Carrying Case 88,000NISTPR44 NIST Traceable Certificate 318,400NISTPR45 NIST Traceable Certificate with Data 400,000

Page 26: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

311Korins Inc. Tel:-031-777-1588 Fax:031-777-1587 Online www.kkkk.com [email protected]

Calibration Equipment

D

Designed for use in remote locations where AC power is not available, this unit enables pressureinstrumentation to be serviced and calibrated.

The instrument features the capability to generate pneumatic test pressures with an integralhand-pump up to 300 psi. A volume adjuster provides fine control of the desired test value and aventing valve enables pressure release without disconnection of the device under test.

An optional pressure/vacuum switching facility can also be provided, which enables thehand-pump to source vacuum down to -22" Hg or pressure up to 300 psi g.

To facilitate pressure transmitter testing and calibration a 24 VDC power supply is pro-vided and the ability to monitor the current loop from 0 to ±55 mA DC.

For loop verification, the unit can also output a single 12mA test value, or provide apassive sink if required.

The clear LCD allows readout of pressure, voltage and current parameters with theability to show current or voltage simultaneously with pressure.

Portable Pressure Calibrator

Catalog No. Model Description PriceDR7750011 DPI603 Portable Pressure Calibrator includes hand pump, volume adjuster, vent value, carrying case, batteries, manual, 2,296,000

electrical test leads and NIST Traceable CertificateDR7750012 DPI603A Portable Pressure Calibrator with pressure vacuum capability 300 PSIG (includes the same accessories as basic unit above) 2,680,000NISTPR44 NIST Traceable Certificate 318,400NISTPR45 NIST Traceable Certificate with Data 400,000

SPECIFICATIONSPressure Measurement SpecificationOperating Pressure Standard full scale ranges can be specified of Ranges -14.7 psig to + 15 psi, + 30 psi, 100 psi or 300psigOverpressure The rated pressure can be exceeded by 2 x

causing negligible calibration change, subjectto a maximum safe working pressure of 350 psi

Pressure Media Fluids compatible with 316 Stainless Steel,Hastelloy C276, Nylon, Viton and brass

Accuracy Combined non-linearity, hysteresis an repeatability± 0.075% F.S. for positive or negative pressures± 1 digit

Temperature Effects Over 32° to 105°, the averaged Span temperaturecoefficient will not exceed 0.007% of reading/°F.

Digital Indicator Readout & Display± 99999 capability, 0.54" LCD digits with additional16 text characters

Pressure Scale Units 24 scale units are providedpsi, lb/ft2, inHg, inH2O, ft of H2O, (40° and 68°F) torr, atm, Pa, kPa, MPa, kPa, mbar, bar, kg/cm2,kg/m2, mmHg, cmHg, mHg, mmH2O, cmH2O,mH2O, Special 2 units are presented on the display

Display Overload Instruments are capable of nominal 120% F.S.Above this, an overrange error code is displayed.

Resolution ± 0.005% F.S. maximumResponse Nominal rate of three readings per second on the

digital displayZero Control Offset correction for pressure and electrical scales

by key-press, protected against accidental use

Calibration Control Front panel key-pad calibration controls forpressure and electrical ranges

Position Effect NegligibleElectrical SpecificationElectrical InputsVoltage MeasurementRange ± 50VAccuracy ± 0.15% of reading ± 0.02% F.S.Temperature Coefficient ± 0.006% reading/°FCurrent MeasurementRange ± 55mAAccuracy ± 0.075% of reading ± 0.005% F.S.Temperature Coefficient ± 0.006% reading/°FElectrical OutputsVoltage output 24V nominal, floating, 25mA maximumCurrent output Loop check fixed 12mA nominal, source or sinkPower SupplyBattery powered 4 x 1.5V zinc carbon “D” cells, 50 hours nominal continuous operationwith no load on output terminals. Battery low condition indicated by display symbolSafetyIEC 1010EMC immunity to IEC 801-804Certification CE markedPhysical SpecificationWeight 9 lbsDimensions 12.6" x 7.7" x 5.0" nominalPressure Connection 1/8" NPT femaleCarrying Case Supplied standard and with a complete set of accessories

Dirt Moisture TrapThe trap has no diaphragm or other internal components which

could create a pressure drop and does not affect calibration accuracy.The trap is simple to dismantle and easy to clean. It should be peri-odically cleaned to prevent excessive contaminate build-up whichmay overflow into the calibrator. The top and bottom sections aresimply unscrewed, releasing the transparent chamber which is thenwiped clean.

The unit is an effective barrier against the transfer of moistureand dirt from an instrument under test to any portable pressure cali-brator. Installed directly on the calibrator pressure port, regular useof the trap will prevent contamination of the calibrator's pneumaticsystem, improve long term reliability and reduce maintenance costs.In addition, it prevents dirt or moisture from one device under testbeing transferred to another via the calibrator.

• Accuracy ± 0.075% F.S.• Integral pressure generation• Standard ranges up to 300 psig• 5 digit LCD, multiple engineering units

• Dual pressure & electrical readout• Transmitter supply & measurement• Current loop verification test• Vacuum generation available

Catalog No. Description PriceDR6002 Dirt moisture trap 3210,000

• Can be used with any pressure calibrator

• Easy to install• Low maintenance• For pneumatic calibrators• Prevents cross-contamination

Page 27: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

305Korins Inc. Tel:031-777-1588 Fax:031-777-1587 Order Online:www.kkkk.com [email protected]

Calibration Equipment

D

Portable Low Pressure Calibrators

SPECIFICATIONSPressure Range Accuracy Max Line Max Differentialin H2O % Span Pressure Pressure± 1.0 in H2O differential 0.05 70 psi 40 in H2O± 5.0 in H2O differential 0.05 300 psi 200 in H2O± 10.0 in H2O differential 0.05 300 psi 200 in H2O± 20.0 in H2O differential 0.05 300 psi 400 in H2O± 30.0 in H2O differential 0.05 300 psi 400 in H2O± 60.0 in H2O differential 0.05 300 psi 400 in H2OAccuracy is defined as non-linearity, hysteresis and repeatability. Temperature effects (averaged with respect to 68°F) ± 0.004% rdg/°F.Calibrator pressure ports - 2 x 1/8 NPT female with 1/8 in. ID tube adapters.Pressure Media - non-corrosive gases.

Catalog No. Description PriceDR639114 Low Pressure Portable Digital Calibrator 6,400,000

Specify Range: +/-1,+/-5,+/-10,+/-20,+/-30, and +/-60 in. H2ODR639184 Low Pressure Portable Digital Documenting Calibrator 7,448,000

Specify Range: +/-1,+/-5,+/-10,+/-20,+/-30, and +/-60 in. H2OStandard OptionsDR191126 NICAD Battery Pack 104,000DR191129 Universal Charger for 110v or 220v 136,000Remote Pressure Sensors (Minimum of one (1) mating cable DR639121 is required when ordering a remote sensor.)DR639120 Remote Pressure Sensor 2,072,000

Specify Range: +/-1,+/-5,+/-10,+/-20,+/-30, and +/-60 in. H2OAccessoriesDR639121 Mating Cable 152,000DR6002 Dirt Moisture Trap 320,000DR781013 "Intecal for Industry" Software 1,280,000DR639211 Spare Carrying Case 88,000NISTPR44 NIST Traceable Certificate 318,400NISTPR45 NIST Traceable Certificate with Data 400,000

Setting the standard for low pressurecalibrators

The Portable Low Pressure Calibrator series ex-tends the general unit pressure capability down to1 in H2O. The LP series combines the easy to useTask menu and electrical measure/source capabilityof the successful LP series with the low-pressuresensor. This makes the low pressure series an idealcalibrator for commissioning, maintaining and cal-ibrating low-pressure transmitters, transducers,gauges, indicators and switches.

At low differential pressures, even connectingthe device under test can induce significant pres-sure. To compensate for this, an “auto zero” facilityis provided which uses an internal solenoid valveto equalize the differential pressure prior to zerocorrection

ApplicationsThe unit is the ideal reference standard to re-

duce instrument maintenance time and errors forquality systems compliance.

Dedicated tasks for transmitters, transducers,gauges, micro manometers and switches, simplifycommissioning, maintenance and calibration.

The unit is designed to calibrate-in-place forvery low-pressure sensors. • Ranges from ± 1 to ± 60 in H2O

• Accuracy 0.05% span• Pressure and Vacuum generation• Automatic zero equalization and system venting• RS 232 interface and documenting version

.

+

*An external squeeze pump is supplied to supplement pressure generation intolarge volumes.

Page 28: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

Korins Inc. Tel:031-777-1588 Fax:031-777-1587 Online www.kkkk.com [email protected]

D

Calib

ratio

n Eq

uipm

ent

314

Pressure Indicator or Pressure Indicator / Current Loop Calibrators

Catalog No. Description PriceDR800S1 Pressure Indicator, Internal Sensor, -15/150psig, 0.05% FS Accuracy 1,456,000DR800P1 Pressure Indicator, Internal Sensor, -15/150psig, 0.01% FS Accuracy 1,704,000DR800S2 Dual Pressure Indicator, Internal Sensors, -15/150psig & 300psig, 0.05% FS Accuracy 2,240,000DR800P2 Dual Pressure Indicator, Internal Sensors, -15/150psig & 300psig, 0.01% FS Accuracy 2,720,000DR802S1 Pressure Indicator / Current Loop Calibrator, Internal Sensor, -15/150psig, 0.05% FS Accuracy 1,656,000DR802P1 Pressure Indicator / Current Loop Calibrator, Internal Sensor, -15/150psig, 0.01% FS Accuracy 2,104,000DR802S2 Dual Pressure Indicator / Current Loop Calibrator, Internal Sensors, -15/150psig & 300psig, 0.05% FS Accuracy 2,640,000DR802P2 Dual Pressure Indicator / Current Loop Calibrator, Internal Sensors, -15/150psig & 300psig, 0.01% FS Accuracy 3,136,000DR800A Soft fabric carrying case with accessory pocket 80,000DR800B Belt clip, strap hanger 33,600DR800C NiMH batteries with charger 144,000DR800E Data logging option 288,000Note: Other internal pressure modules are available for single or dual channel indicators

SPECIFICATIONSDR802Measure Accuracy0 to 55.000 mA 0.02% of reading + 3 countsSwitch Detection Open and closed, 2 mA currentLoop Power Output 24 V ± 10% (35 mA maximum)HART mA 250 Ω (menu selection)Loop Resistor Dimensions 7.1" L x 3.3" W x 2" H (180mm x 85mm x 50mm)Weight 18 oz (500g)Power 3 AA alkaline (>50 hrs. measure,

<10 hrs 24V source)Supplied with batteries, calibration certificate, and user guide.DR802 models also include a set of electrical test leads.

• Ranges from 10in H2O to 10,000 psi• Single or dual range configuration• mA measure, switch test and 24V loop power • Large backlit display, menu driven interface• HART® loop resistor• Robust and weatherproof• Convenient, one-handed operation• Plug and play connector for Universal Pressure Modules• Universal Pressure Modules available from 10in H2O to 10,000 psi

(25 mbar to 700 bar)• External Pressure Modules available, see page 275• Plug and Play Modules are interchangeable between instruments,

requiring no set-up or instrument calibration

DR800 Pressure Indicator• Pressure Ranges 10in H2O to 10,000 psi

(25 mbar to 700 bar) including vacuum options

• All-Inclusive Accuracy• Dual Sensor Configuration provides two simultaneous readings• Stainless Steel Sensor Construction available• Programmable Leak Test• Hold, maximum / minimum / average, alarm, and tare

DR802 Pressure Indicator / Current Loop Calibrator• Provides simultaneous pressure and mA measurement• Dual Readings• 24V Loop Power Supply • Automatic Switch Test • HART Resistor - Can be switched into the loop when required for a

HART digital communicator

External Pressure ModulesSee page 243

We Accept: Visa, American Express,MasterCard and Discover

Page 29: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

321Korins Inc. Tel:031-777-1588 Fax:031-777-1587 Online: www.kkkk.com [email protected]

Calibration Equipment

D

Portable Pressure Calibrator

Catalog No. Description PriceAM87126 Indicator; Vacuum to 10 psi / Vacuum to 0.7 bar 1,822,400AM87127 Indicator; Vacuum to 30 psi / Vacuum to 2 bar 1,822,400 AM87128 Indicator; Vacuum to 200 psi / Vacuum to 15 bar 1,822,400AM87129 System A; Vacuum to 10 psi with an AM900201 pneumatic hand pump 3,073,600AM87130 System A; Vacuum to 30 psi with an AM900201 pneumatic hand pump 3,073,600AM87131 System A; Vacuum to 200 psi with an AM900201 pneumatic hand pump 3,073,600AM87132 System B; Vacuum to 200 psi with a combination hand pump 3,225,600NISTPR44 NIST Traceable Certificate 318,400NISTPR45 NIST Traceable Certificate with Data 400,000

Available as an indicator or a system - a reliable, accurate, and fast pressure calibrator

SPECIFICATIONSAM87126 AM87127 AM87128

Pressure Range Vacuum to 10 psi/0.7 bar Vacuum to 30 psi/2 bar Vacuum to 200 psi/ 15 barAccuracyPositive Pressure ± 0.05% of Full ScaleVacuum ± 0.1% of Full ScaleUnits psi, bar, mbar, kPa, Kg/cm3, cmH2O @ 4°C, cmH2O @ 20°C, mH2O @ 4°C, mH2O @ 20°C, inH2O @ 4°C,

inH2O @ 20°C, inH2O @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH2O @ 4°C, ftH2O @ 20°C, ftH2O @ 60°FCompatibility Non-Corrosive Liquids and GasesPower Supply (1) 9V BatteryBattery Life 15 Hours minimumAuto Switch Off YESLow Battery Indication On DisplayOverpressure Indication On DisplayUnit Dimensions (L x H x W) 7.9 x 3.2 x 2.1 in (200 x 82 x 54 mm)Unit Weight 17 oz. (470 g)Display Dual line information display with Icon indicatorsmA Input 0 to 24 mA / -25.00 to 125.00%Switch Test YESMin/Max Peak Hold capture YESStandard deliveryIndicator Indicator, Soft Case, Test Leads, Manual, Imperial and Metric FittingsSystem A (AM87129/AM87130/AM87131) Indicator, Soft Case, Test Leads, Manual, Imperial & Metric Fittings, Pneumatic Hand pump,

Aluminum Carrying CaseSystem B (AM87132) Indicator, Soft Case, Test Leads, Manual, Imperial & Metric Fittings, Pneumatic Combination Hand pump,

Aluminum Carrying Case

Compact Pressure CalibratorThese Compact Pressure Calibrators are

portable, self-contained instruments designedespecially for accurate, convenient calibration ofelectronic pressure transmitters, transducers,switches, gauges, and other pressure measuringinstruments.

The calibrator is supplied in all configurationswith an accuracy of ±0.05% F.S. and includes BSPand NPT fittings, a soft carrying case, and operat-ing manual. In system configurations, adaptersand a hard system case are included.

System A: PneumaticHandpumps

This ready-to-use calibrationsystem includes the Indicator with a pneumatic hand pump as a preci-sion pressure source. Units may besupplied with NIST data if required.

System B: CombinationHand pumps

This ready-to-use calibra-tion system includes theIndicator with a combinationvacuum / pressure hand pumpas a precision pressure source.Units may be supplied withNIST data if required.

• Three combination ranges• Available as an indicator

or system• Easy-to-use keypad• Large 2 line display• Switch Test• mA reading for Transmitter

calibration• NPT and BSP adapter

standard

Page 30: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

319Korins Inc. Tel:031-777-1588 Fax:031-777-1587 Order Online: www.kkkk.com [email protected]

Calibration Equipment

D

Pressure/Vacuum CalibratorsPressure Calibrator Vacuum to 15,000 psi with 0.025% accuracy

Catalog No. Description Stocked Ranges (any custom range is possible) PriceSIPC6PRO2I3P Complete kit / indicator head -30"Hg to 30 psi 4,432,000SIPC6PRO20I3P Complete kit / indicator head -30"Hg to 300 psi 4,432,000SIPC6PRO40I3P Complete kit / indicator head -30"Hg to 600 psi 4,432,000SIPC6PRO350I3H Complete kit / indicator head 0 to 5,000 psi 5,272,000SIPC6PRO700I3H Complete kit / indicator head 0 to 10,000 psi 5,272,000SIPC6PRO1000I3H Complete kit / indicator head 0 to 15,000 psi 6,151,200SIPC6PRO2C3P Complete kit / calibrator head -30"Hg to 30 psi 5,024,000SIPC6PRO20C3P Complete kit / calibrator head -30"Hg to 300 psi 5,024,000SIPC6PRO40C3P Complete kit / calibrator head -30"Hg to 600 psi 5,024,000SIPC6PRO350C3H Complete kit / calibrator head 0 to 5000 psi 5,864,000SIPC6PRO700C3H Complete kit / calibrator head 0 to 10,000 psi 5,864,000SIPC6PRO1000C3H Complete kit / calibrator head 0 to 15,000 psi 7,022,400SIPC6IS2C3P Complete kit / intrinsically safe head -30"Hg to 30 psi 5,024,000SIPC6IS20C3P Complete kit / intrinsically safe head -30"Hg to 300 psi 5,024,000SIPC6IS40C3P Complete kit / intrinsically safe head -30"Hg to 600 psi 5,024,000SIPC6IS350C3H Complete kit / intrinsically safe head 0 to 5,000 psi 5,864,000SIPC6IS700C3H Complete kit / intrinsically safe head 0 to 10,000 psi 5,864,000SIPC6IS1000C3H Complete kit / intrinsically safe head 0 to 15,000 psi 7,022,400NISTPR44 NIST Traceable Certificate for Test Gauges 320,000NISTPR45 NIST Traceable Certificate with Data for Test Gauges 400,000

• Voltage and current measurement and sourcing• Optional Windows™-based software available for remote operation and

data transfer (availableupon request)

• Can accept externalpressure modules

• Pressure switch test• Leak rate measurement

from 1 second to 999 days• Display hold capability• Simultaneous display

(pressure & electrical units)• Adjustable resolution• All kits include carry case, adapter fittings, battery charger, test leads

and NIST Certificate

This series of pressure calibrators utilizes thelatest developments in pressure instrumentationto offer a versatile calibration instrument in ahighly portable package. The calibrator head canbe supplied by itself or as a complete kit withpneumatic or hydraulic pump, NPT fittings, pres-sure hose and carrying case.

The compact size of the unit does not compromise functionality. It can simultaneouslydisplay pressure versus voltage, current, date &time, percentage of pressure, pressure switch status, temperature, maximum or minimum values. Data can be logged and stored with timeand date stamping for future reference. Windowsbased software can be linked to the unit for re-mote operation and data transfer.

The base unit offers very accurate pressuremeasurement along with current and voltagemeasurement and sourcing for calibration of pres-sure transmitters. Intrinsically safe models areavailable.

SPECIFICATIONSAccuracy 0.025% FSOperating Temperature 32 to 104°F (0 to 40°C)Units PSI, bar, H20, Hg, mmHg (other units available)Display Backlit LCD, 16 character, 2 lineResolution 0.01% FSPower Supply 6V NiCad rechargeable with 110VAC charger

suppliedBattery Life 10 hours (fully charged)Calibration Medium Air, oil, waterConnections 7 pc. NPT adapter fitting provided with kits Weight 3.5 lbs (head only)Certification NIST Calibration Certificate

Page 31: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

Korins Inc. Tel:031-777-1588 Fax:031-777-1587 Order Online:www.kkkk.com [email protected]

D

Calib

ratio

n Eq

uipm

ent

326

Four-In-One Hand Pump

Catalog No. Description PriceGE411AHA Four-In-One Hand Pump Kit 1,656,000GE411A Four-In-One Hand Pump Only 1,328,000GE411A116 200cc Reservoir for GE411A Hand Pump 400,000The GE411AHA Hand Pump kit includes Heavy-duty transport case with closed foam insert, 10,000 PSI high pressure hose assembly 3ft length, 2 - 1/4"Male NPT adaptors, 1 - 1/4" Female NPT adaptor, 1 - 1/8" Male NPT adaptor, 1 - 1/8" Female NPT adaptor and 1 - 1/4" Male to 1/8" Female adaptor.

High quality, field-proven pressure and vacuum hand pump

SPECIFICATIONSPressure Ranges Pneumatic 0-600 PSIHydraulic 0-10,000 PSIVacuum 0-28.5 inHgHydraulic Media Distilled water (no alcohol) or High viscosity

mineral oilPressure Connection 1/4" NPT femaleReservoir Connection 1/4" BSP femaleReservoir Volume 100 ccOptional Large Reservoir 200 cc

• Vacuum priming function to remove air during hydraulic operation• High pressure generation accomplished with volume adjuster rather

than physical effort• Tamper-proof adjustable overpressure protection valve• 240° swivel head for optimum viewing of reference indicators• Pressure/vacuum selector provides fine control in both pneumatic and

hydraulic modes• High sensitivity volume adjuster for hydraulic, pneumatic, vacuum and

low pressure operation• Built-in stroke adjuster controls pressure/vacuum generated per stroke• Teflon anodized internal moving parts for reduced friction and wear• Removable hydraulic reservoir can be disconnected from pump with-

out draining

The PV411A provides functionality never be-fore seen in a hand held pressure source. It canreplace four conventional hand pumps.

• Send Us Your Equipment List orJust a Few Sample Items

• Let Us Show You How Korins Inc.Can be Your One Source and SaveYou Money

• www.kkkk.com

Page 32: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

Korins Inc. Tel:031-777-1588 Fax:031-777-1587 Order online: www.kkkk.com [email protected]

D

Calib

ratio

n Eq

uipm

ent

324

Hydraulic Hand Pumps Easy Pressure Generation to 15,000 psi

Davis Inotek Instruments offers the best se-lection of hand-held, portable pumps — supply-ing pressure generation with standard fine-tuning adjustments and pressure relief valves.These pumps are ideal for use with electroniccalibrators, digital indicators, analog gauges,pressure transmitters, transducers, reliefvalves, or similar instrumentation.

The rugged and reliable design of thesepumps and the fine adjustment controls addedto their design provide a low cost way to verifythe performance of pressure instrumentation.Pumps can be purchased independently, or in akit including carrying case, NPT adapters,seals and hoses.

The SHTP1 hydraulic pump is currently theonly hand pump capable of generating pressureup to 15,000 psi, utilizing hydraulic oil, Skydrolor distilled water. The pump includes a uniquehigh pressure or priming selector on the scissoraction pump mechanism, making pressure generation above 5,000 psi easier.

• Hand-held pressure generation• Low-cost way to verify performance of pressure instrumentation• Rugged and reliable design• Fine adjustment control• Optional pressure relief valves• The most efficient pumps available — 4 strokes to 5,000 psi

Catalog No. Model Description PriceSIPHTP1700 SHTP1-700 Hydraulic pump, 10,000 psi 1,320,000SIPHTP1700K SHTP1-700K 10,000 psi pump kit with carrying case, 7-piece adapter fittings and hose kit 2,152,000SIPHTP11000 SHTP1-1000 Hydraulic pump, 15,000 psi 1,656,000SIPHTP11000K SHTP1-1000K 15,000 psi pump kit with carrying case, 7-piece adapter fittings and hose kit 2,488,000SIPHK11000 HK1-1000 15,000 psi hydraulic hose kit, with NPT adapters 472,000SIPPRV121 PRV12-1 Pressure relief valve, 150 to 750 psi 312,000SIPPRV122 PRV12-2 Pressure relief valve, 750 to 3,000 psi 312,000SIPPRV123 PRV12-3 Pressure relief valve, 3,000 to 6,000 psi 312,000SIPPRV124 PRV12-4 Pressure relief valve, 6,000 to 10,000 psi 312,000SIPPRV125 PRV12-5 Pressure relief valve, 10,000 to 15,000 psi 312,000NISTPR44 NIST Traceable Certificate for test gauges 318,400NISTPR45 NIST Traceable Certificate with Data for test gauges 400,000

SPECIFICATIONS — SHTP1Pressure Range

SHTP1 - 700 0 to 700 bar/10,000 psiSHTP1 - 1000 0 to 1000 bar/15,000 psi

Pressure Media Mineral based hydraulic oil or Distilled water (‘Skydrol’ and brake fluid available SHTP1-S)

Pressure Connections 3/8" BSP female indication, 1/4" BSP female (process), 1/4" NPT female adapters

Weight 3.5 lb.Volume 100cc

Korins Quality System Meets the Requirements of:• FDA

• QS-9000

• TL-9000

• MIL-STD 45662A

• MIL-I 45208A

• MIL-Q 9858A

• 10CFR50 App.B

• NIST Traceable

• ISO 9001:2000 Registered

• ISO 17025 Accredited by A2LA and ACLASS

Page 33: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

Korins Inc. Tel:031-777-1588 Fax:031-777-1587 www.kkkk.com [email protected]

D

Calib

ratio

n Eq

uipm

ent

328

Pneumatic Hand Pumps Pressure and Vacuum Generation in One Rugged Design

SLTP1

SPECIFICATIONS — STP1Output pressure 0 to 40 bar/600 psiOutput vacuum 0 to -0.9 bar/0 to -28"HgMaterials Bright nickel plated brass, clear anodized

aluminumAdjustment Fine volumetric pressure/vacuum adjusterWeight 1.5 lb.

SPECIFICATIONS — SLTP1Output Pressure 0 to 2 bar/30 psiOutput Vacuum 0 to -850 mbar/0 to -25"Hg Materials Bright nickel plated brass, clear anodized

aluminumAdjustment Fine volumetric pressure/vacuum adjuster with 0.1 mbar / 0.00145 psi sensitivityWeight 1.5 lb.

Davis Instruments offers the best selection ofhand-held, portable pumps — supplying pressuregeneration with standard fine-tuning adjustmentsand pressure relief valves. These pumps are idealfor use with electronic calibrators, digital indica-tors, analog gauges, pressure transmitters, trans-ducers, relief valves, or similar instrumentation.

The rugged and reliable design of these pumpsand the fine adjustment controls added to their de-sign provide a low cost way to verify the performanceof pressure instrumentation. Pumps can be pur-chased independently, or in a kit including carryingcase, NPT adapters, seals and hoses.

The STP1 pneumatic pump generates pressureto 600 psi and vacuum to 28"Hg on the same unit.Made with no plastic parts these pumps are de-signed to endure harsh environments unlike ourcompetitor’s disposable models.

The SLTP1 pneumatic pump also acts as a dualsource of pressure and vacuum over smallerranges making very fine adjustments easier. TheSLTP1 range is 25"Hg vacuum to 30 psi, with0.00145 psi sensitivity.

Catalog No. Model No. Description PriceSIPTP140 STP1 Pneumatic pump & vacuum, 600 psi to -28 inHg 824,000SIPTP140K STP1 600 psi to -28 inHg pump & vacuum kit with carrying case, 5-piece adapter fittings and hose kit 1,080,000SIPLTP1 SLTP1 Pneumatic pump & vacuum, 30 psi to -25 inHg 824,000SIPLTPIK SLTP1 30 psi to -25 inHg pump & vacuum kit with carrying case, 5-piece adapter fittings and hose kit 1,080,000SI0100424NPT Pneumatic hose assembly with NPT fitting 136,000NISTPR44 NIST Traceable Certificate for test gauges 318,400NISTPR45 NIST Traceable Certificate with Data for test gauges 400,000

STP1

• Hand-held pressure and vacuum generation• Low-cost way to verify performance of pressure instrumentation• Rugged and reliable design• Fine adjustment control• The most efficient pumps available

Page 34: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

Catalog No. Description PriceGE3301000 High Pressure Hydraulic Calibrator; pressure range, 1000 psi gauge 11,998,400GE3302000 High Pressure Hydraulic Calibrator; pressure range, 2000 psi gauge 11,998,400GE3303000 High Pressure Hydraulic Calibrator; pressure range, 3000 psi gauge 11,998,400GE3305000 High Pressure Hydraulic Calibrator; pressure range, 5000 psi gauge 11,998,400GE33010K High Pressure Hydraulic Calibrator; pressure range, 10000 psi gauge 11,998,400GE3351000 Documenting High Pressure Hydraulic Calibrator; pressure range, 1000 psi gauge 11,998,400GE3352000 Documenting High Pressure Hydraulic Calibrator; pressure range, 2000 psi gauge 11,998,400GE3353000 Documenting High Pressure Hydraulic Calibrator; pressure range, 3000 psi gauge 11,998,400GE3355000 Documenting High Pressure Hydraulic Calibrator; pressure range, 5000 psi gauge 11,998,400GE33510K Documenting High Pressure Hydraulic Calibrator; pressure range, 10000 psi gauge 11,998,400Note: Absolute pressure ranges are also available.Instrument Includes: Rechargeable cell, Battery charger, Test lead, User guide, and Calibration certificate.

SPECIFICATIONSPressure Source Internal hydraulic reservoirRecommended Media Mineral oil or distilled waterTemperature Operating range 15° to 120°F, Calibrated 15° to 105° FHumidity 0 to 90% non-condensingSealing NEMA 12 (IP54)Power Supply Battery powered 7.2V NiMH cell – will operate from AC power supply 85V to 265V, 45 to 400Hz – while battery pack recharges

The calibrators come in two versions: a stan-dard model (GE330) and a model with full docu-menting capability (GE335). A unique vacuumpriming function combined with a precision regu-lator / fine volume adjuster provide effortlesspressure generation to 10,000 psi. The built-inthermal compensator ensures the highest level ofstability and control. Each unit features accuracyto better than 0.025% of full scale.

• High accuracy; 0.025% FS • Generates pressures up to 10,000 psi • Dual pressure and electrical readout • Built-in thermal compensator for high speed stable control • Unique vacuum priming system • RS 232 interface• Optional remote sensors available• Process functions: filter, max/min, tare, flow and % spanDPI 335 • Error analysis with pass / fail status and graphs• Storage of As Found and As Left results• Two way PC interface for transferring test procedures and results• Compatible with Intecal for Industry (i4i) Software

SPECIFICATIONSPressure Range Accuracy*(% FS) Maximum Overpressure Type1000 PSI 0.025% 2000 PSI G or A2000 PSI 0.025% 4000 PSI G or A3000PSI 0.025% 6000 PSI G or A5000 PSI 0.025% 10,000 PSI G or A10,000 PSI 0.025% 12,000 PSI G or A* Combined non-linearity, hysteresis and repeatability

Korins Inc. Tel:031-777-1588 Fax:031-777-1587 www.kkkk.com [email protected]

D

Calib

ratio

n Eq

uipm

ent

330

Portable High Pressure Hydraulic CalibratorsMakes testing of hydraulic pressure instruments quick and easy

World-Class Calibration

Page 35: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

331Korins Inc. Tel:031-777-1588 Fax: 031-777-1587 www.kkkk.com [email protected]

Calibration Equipment

D

Portable High Pressure Pneumatic Calibrators

Catalog No. Description Range PriceDR320500 Standard High Pressure Portable Pneumatic Calibrator 500 psi gauge or absolute 9,592,000DR3201000 Standard High Pressure Portable Pneumatic Calibrator 1000 psi gauge or absolute 9,592,000DR3201500 Standard High Pressure Portable Pneumatic Calibrator 1500 psi gauge or absolute 9,592,000DR3202000 Standard High Pressure Portable Pneumatic Calibrator 2000 psi gauge or absolute 9,592,000DR3203000 Standard High Pressure Portable Pneumatic Calibrator 3000 psi gauge or absolute 9,592,000Standard models include built-in rechargeable gas cylinder, rechargeable battery pack and charger, calibration certificates, test leads and manual.DR325500 Deluxe Documenting High Pressure Portable Pneumatic Calibrator 500 psi gauge or absolute 10,320,000DR3251000 Deluxe Documenting High Pressure Portable Pneumatic Calibrator 1000 psi gauge or absolute 10,320,000DR3251500 Deluxe Documenting High Pressure Portable Pneumatic Calibrator 1500 psi gauge or absolute 10,320,000DR3252000 Deluxe Documenting High Pressure Portable Pneumatic Calibrator 2000 psi gauge or absolute 10,320,000DR3253000 Deluxe Documenting High Pressure Portable Pneumatic Calibrator 3000 psi gauge or absolute 10,320,000Deluxe documenting version includes built-in rechargeable gas cylinder, rechargeable battery pack and charger, calibration certificates, test leads and manual.

SPECIFICATIONSThe Calibrators include a built-in pressure sensor and matched pressure regulator. The pressure range should be selected from the table below.Pressure Range Accuracy* (% F.S.) Max. Overpressure Type**500 psi 0.025% 1000 psi G or A1000 psi 0.025% 2000 psi G or A1500 psi 0.025% 3000 psi G or A2000 psi 0.025% 4000 psi G or A3000 psi 0.025% 6000 psi G or A*Combined non-linearity, hysteresis and repeatability. **G = Gage, A = Absolute (pressure reference).

Temperature Effects (averaged and w.r.t. 68°F) 0.002% of rdg/°F.Pressure source Built-in Nitrogen/Air cylinder, (max refill pressure 3000psi). Storage volume 122 cubic inches.

Capacity 14.0 cubic feet. Recommended media Oxygen Free Nitrogen (OFN).Remote Pressure Sensors Please consult factory for list.ElectricalIn addition to pressure, the dual display can simultaneously monitor mA, V, switch, continuity and ambient temperature. Also, 10Vd.c. and 24Vd.c. power supplies areavailable for the Device Under Test.Input Range Accuracy Resolution RemarksVoltage* ± 50Vd.c. 0.05% Rdg 0.004% F.S. 100 microVmax Autoranging>10MWCurrent* ± 55mA 0.05% RDG 0.004% F.S. 0.001mA 10W, 50V max.Temperature 15°F to 105°F ± 2°F 0.1°F Case ambientSwitch Open/Closed 5mA whettingOutput Range Accuracy Resolution RemarksVoltage 10Vd.c. 0.1% Max. load 10mAVoltage 24Vd.c. 5% 0.001mA Max. load 26mACurrent* 0 to 24mA 0.05% Rdg 0.01% F.S.*Temperature coefficient 0.004% reading/°F w.r.t. 68°F

The Portable High Pressure Pneumatic Calibrators Seriesis designed to make testing and calibration of high pressure in-struments and systems both quick and simple. Two versionsare available, the standard model and the deluxe which hasfull documenting capability. These self-contained portable cal-ibrators provide unparalleled accuracy and control perfor-mance. A built-in gas cylinder provides source pressures up to3000 psi, a precision pressure regulator and fine volume ad-juster ensures optimum control and a digitally characterizedsensor measures pressure to better than 0.025% of full scale.

• Pressure units - 25 scale units plus one user defined.• mA source - Auto10-sec. step cycle and programmable (60 sec. end to end) ramp• Process functions - Filter, max/min, tare, flow, and % span.• Power management - Auto power OFF, auto backlight OFF, battery status indicator.• Display - 2.36 x 2.36 inches graphic LCD with backlight. +/-99999 readout, 2 reading

per second.• Data Storage - 92 kbytes memory.• High accuracy 0.025% FS• Generates pneumatic pressures to 3000 psi• Dual channel readout: pressure and electrical • Self contained rechargeable gas cylinder• RS 232 interface and documenting versions• Coarse/fine adjust selection

Page 36: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

343Korins Inc. Tel: 031-777 -1588 Fax: 031- -777-1587 www.kkkk.com [email protected]

Calibration Equipment

D

Pressure CalibratorRobust, Portable and Accurate Pressure Calibration up to 10,000 PSI

High accuracy and stability are achieved by use of aspecial thin film strain gauge transducer with built-intemperature compensation. Unlike some otherpressure calibrators, accuracy is maintained whendecreasing pressure which makes the unit ideal forverification of hysteresis. All units are calibrated inpositive as well as in negative direction.

Originally designed for use on offshore drilling rigs,these compact and rugged pressure calibrators offerreliable performance under the most severe conditions.This unit’s low weight of only 18 lbs. makes the unitsideal for on-site calibration.

Each unit is supplied with a calibration certificate afterbeing calibrated against precision pressure equipmenttraceable to national standards. Full documentation andrecord keeping of calibrations are easily carried out by useof a Windows®-based software.

This unit is simple and easy with test pressurebeing established by the integrated hydraulic pump andcalibration pressure being read on the LCDdisplay. There is no need for fragile reference gauges.

Catalog No. Description PriceTC7051K Pressure calibrator, PC705, 1000 PSI, 0.03% accuracy 7,512,000TC7053K Pressure calibrator, PC705, 3000 PSI, 0.03% accuracy 7,512,000TC7055K Pressure calibrator, PC705, 5000 PSI, 0.03% accuracy 7,512,000TC70510K Pressure calibrator, PC705, 10000 PSI, 0.03% accuracy 7,512,000

• Range 0 to 10,000 psi• Input for External Sensor• Accurate to ± 0.03%FS• mA,V and Switch Test Input• History Log• Programmable Engineering Units• RS232 Interface• EEx/IS Approved for Hazardous Areas• Portable and Lightweight

SPECIFICATIONSPressure Ranges 0 to 10,000 psiAccuracy ± 0.03% FS (10-40°C), temperature effects: 0.001%

of reading/°CmA Input 0-30mA (± 0.03% FS), Ambient 25°C, temperature

effects: ± 0.008%/°CV Input 0-15VDC (± 0.05% FS), Ambient 25°C, temperature

effects: ± 0.008%/°CHistory Log 30 sensors, 10 points eachOperating Temperature 0 to + 50°C (ambient)Process Temperature -20 to + 80°CPressure Overload FS x 1.5Wetted Parts Hastelloy C-22Housing Anodized aluminumPressure Media OilOperating Time Approximately 35 hourson BatteriesFunctions Programmable: Input mA/mV/V/Switch Test, Range,

Conversion, Engineering Units, Filter.Min/Max/Tare, History Log, Internal/External Sensor,Battery Indicator, Leak Test, Selectable Language(optional), Remote Operation (optional)

Engineering Units Bar, kPa, Mpa, atm, psi (lb/in2), at (kgf/cm2), torr,mHg at 0°C, inHg at 32°F, cmH2O at 4°C, mH2O at4°C, inH2O at 39.2°F

Overall Dimensions 13.6" x 6.3" x 7" (WxHxD)Weight 18 lbs. (8.1 kg)EEx /IS Certification EEx ia IICT5ATEX Production NEMKO 02ATEX445Q ATEX according to directive Notification 94/9/ECDelivery Carrying case, fittings, calibration certificate,

Pre-Cal software and instruction manual

Page 37: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

¤¿¤ÀKorins Inc. Tel:031-777-1588 Fax:031-777-1587 Order Online www.kkkk.com

D

Calib

ratio

n Eq

uipm

ent

292

Electrical Loop Calibrator

Catalog No. Description PriceDR832 Electrical Loop Calibrator 1,592,000DR800A Soft fabric carrying case with accessory pocket 800,000DR800B Belt clip, strap hanger 33,600DR800C NiMH batteries with charger 144,000DR800D RS232 Cable 76,800DR800E Data logging option 288,000Calibrator supplied with batteries, calibration certificate, and user guide.

Universal Pressure Input Modules areavailable from 10in H2O to 10,000 psi (25 mbar to 700 bar).

Plug and Play Modules are interchangeable between instruments, requiring no set-up or instrument calibration.

SPECIFICATIONSMeasure Accuracy0 to 120.00 mV 0.02% of rdg + 2 counts0 to 30.000 V 0.03% of rdg + 2 countsSource Accuracy0 to 120.00 mV 0.02% of rdg + 2 counts0 to 12.000 V 0.02% of rdg + 2 counts0 to 24.000 mA 0.02% of rdg + 2 countsThe following are available independently or simultaneously with the above ranges:Measure Accuracy0 to 55.000 mA 0.02% of rdg + 3 countsSwitch Detection Open and closed, 2 mA currentLoop Power Output 24 V ± 10% (35 mA maximum)HART mA Loop Resistor 250 Ω (menu selection)Dimensions 7.1" L x 3.3" W x 2" H

(180mm x 85mm x 50mm)Weight 14 oz (400g)Power 3 AA alkaline >60 hrs. frequency measure,

11 hrs mA source (24V @ 12mA)

• Dual reading capability: Source mA, mV or V and simultaneouslymeasure mA or capture switch trip values

• Measure or Source mA, mV and V• 24V loop power supply• Programmable Step & Ramp Outputs• Large backlit display, menu driven interface• HART® loop resistor• Robust and weatherproof• Convenient, one-handed operation• Plug and play connector for Universal Pressure Modules

• Adjustable “Nudge” Value - Provides an incremental output for settingswitches, relays, trips and alarms

• Advanced Features - Hold, maximum/minimum/average (with timestamp), scaling, tare (offset) and damping filter facilitate systemchecks and troubleshooting

• Two Independent 24 V Loop Power Supply • Automatic Switch Test • HART Resistor - Can be switched into the loop when required for a

HART digital communicator

External Pressure ModulesSee page 243

Fast, FriendlyService.Fast, FriendlyService.Need More Information about a product? Ask for Technical ServiceNeed More Information about a product? Ask for Technical Service.

Page 38: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

289Korins Inc. Tel:031-777-1588 Fax:031-777-1587 Order Online www.kkkk.com [email protected]

Calibration Equipment

D

Frequency and Frequency / Current Loop Calibrators

Catalog No. Description PriceDR841 Frequency Calibrator 1,912,000DR842 Frequency Loop Calibrator 2,392,000DR800A Soft fabric carrying case 80,000

with accessory pocketDR800B Belt clip, strap hanger 33,600DR800C NiMH batteries with charger 144,000DR800E Data logging option 288,000

SPECIFICATIONSMeasure Accuracy0 to 999.999 Hz 0.003% of rdg + 2 counts0 to 50.0000 kHz 0.003% of rdg + 2 counts0 to 999999 cpm/cph 0.003% of rdg + 2 counts0 to 999999 total countSource Accuracy*0 to 999.99 Hz 0.003% of reading + 0.0023 Hz0 to 50.000 kHz 0.003% of reading + 0.0336 KHz0 to 99999 cpm 0.003% of reading + 0.138 cpm0 to 99999 cph 0.003% of reading + 0.5 cph0 to 999999 pulse with variable rate 0 to 99999 HzWaveform sine, square and triangular (unipolar or bipolar)Voltage Input 30 V maximumTrigger Level 0 to 24 V, resolution 0.1 VOutput Amplitude 0 to 24 VDC ± 1% (20 mA max), 0 to 24 VAC ± 5% (20 mA max)DR842 Additional SpecificationsMeasure Accuracy0 to 55.000 mA 0.02% of reading + 3 countsSwitch Detection Open and closed, 2 mA currentLoop Power Output 24 V ± 10% (35 mA maximum)HART mA Loop Resistor 250 Ω (menu selection)Dimensions: 7.1" L x 3.3" W x 2" H (180mm x 85mm x 50mm)Weight 14 oz (400g)Power 3 AA alkaline (>60 hrs. frequency measure, 10 hrs mA source (24V @ 12mA)Calibrators supplied with batteries, calibration certificate, and user guide.

DR841 Frequency Calibrator• Measures or sources Hz, kHz, CPM, CPH and pulses• Automatic Trigger • Frequency Scaling • Programmable Step & Ramp Outputs • Adjustable “Nudge” Value - Provides an incremental output for setting

switches, relays, trips and alarms• Advanced Features - Hold, maximum/minimum/average (with time

stamp), scaling, tare (offset) and damping filterDR842 Frequency / Current Loop Calibrator• Dual Readings - simultaneous frequency output and mA

measurement• 24 V Loop Power Supply • Automatic Switch Test • HART Resistor - Can be switched into the loop when required for a

HART digital communicator

• Advanced frequency meter / generator with three output waveformsfrom 0.1 V to 24 V amplitude

• Measure or source 0.01 Hz to 50 kHz• CPM, CPH and totalizing counter• Sine, square and triangular waveforms• mA measure, switch test and 24V loop power• Large backlit display, menu driven interface• HART® loop resistor• Robust and weatherproof• Convenient, one-handed operation• Plug and play connector for Universal Pressure Modules• Universal Pressure Input Modules are available from 10in H2O to

10,000 psi (25 mbar to 700 bar).• External pressure modules available, see page 275• Plug and Play Modules are interchangeable between instruments,

requiring no set-up or instrument calibration

External Pressure ModulesSee page 243

Page 39: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

Korins Inc. Tel:031-777-1588 Fax:031-777-1587 www.kkkk.com [email protected]

D

Calib

ratio

n Eq

uipm

ent

378

Tight tolerance laboratory grade decade substituters, for applications requiring acost effective high performance resistance decade box.

Catalog No. Total Res. (Ω) Res. (Ω) Decades PriceET143310 1,111.1 0.01 5 3,672,000ET143312 11,111 0.1 5 3,576,000ET143319 1,111.11 0.001 6 4,152,000ET143320 11,111.1 0.01 6 3,832,000ET143322 111,111 0.1 6 3,992,000ET143328 11,111.11 0.001 7 5,264,000ET143329 111,111.1 0.01 7 4,600,000ET143331 1,111,111 0.1 7 5,088,000ET143339 1,111,111.11 M 0.001 9 5,568,000ET1433391 11,111,111.1 M 0.01 9 7,032,000ET1433392 111,111,111 M 0.1 9 7,672,000ET143340 11,111,111,110 M 0.001 10 7,352,000ET1433401 111,111,111.1 M 0.01 10 7,992,000ET143341 111,111,111.11 M 0.001 11 8,632,000

• Accepted industry standard• Resistance from 1 mΩ to 111 MΩ• Excellent stability - 10 ppm/yr, 25 ppm/ 3 yrs• Wide choice - single through 11 decade units• High accuracy - 0.01% (100 ppm)• Very low zero resistance: <1 mΩ per decade• High performance solid silver alloy switches • Low temperature coefficient - 5 ppm/°C• Non-inductive or low inductance resistors • Rack mounting available• Special and custom configurations available

SPECIFICATIONSOverall Accuracy ±(0.01% + 2 mΩ)Zero Resistance 1 mΩ/decade at dc; 0.04 Ω at 1 MHz;Maximum Voltage 2000 V peak (to case)Temperature Coefficient: in ppm/°C: 5 ppm for 100 Ω through 100 kΩ steps;

10 ppm for 1 MΩ and 10 MΩ steps; 15 ppm for 10 Ω steps; 20 ppm for 1 Ω steps and below.

Terminals Gold-plated tellurium-copper, low-thermal-emf 5-way binding postsMechanical 4-decade: 12.3 x 3.5 x 5.0 in (312 x 89 x 127 mm); 1.6 kg

5-decade: 14.8 x 3.5 x 5.0 in (375 x 89 x 127 mm); 1.8 kg6-decade: 17.3 x 3.5 x 5.0 in (439 x 89 x 127 mm); 2.0 kg7-decade: 17.3 x 5.3 x 5.0 in (439 x 135 x 127 mm); 2.7 kg8-11-decade: 19.0 x 7.0 x 7.8 in (483 x 178 x 197 mm); 3-6 kg

High Accuracy Decade Resistor

DAVIS INOTEK PRE-OWNED SUPERSTORE

Rent, Lease or Purchase Quality Pre-Owned Instruments with Discounts up to 90% Off List Prices

Rent Rent to Own Lease PurchaseCall Toll Free: 800-446-0088 Online: www.usedtestgear.com

Page 40: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

381Korins Inc. Tel:031-777-1588 Fax:031-777-1587 www.kkkk.com [email protected]

Calibration Equipment

D

Catalog No. Description PriceGRTD100 RTD Simulator ± 0.01% 3,192,000GRTD100X RTD Simulator ± 0.005% 4,792,000

SPECIFICATIONSRTD100X and RTD100Resistance Range 10.000 to 1111.110Number of Decades 6Resolution (least significant decade) 0.001ΩMaximum Current for Rated Accuracy10.000 to 99.999 75 mA100.000 and up 25 mASwitch Life Rating (operations) (typical) > 100,000Resistor Tempco (ppm/°C) 3 typ / 5 maxResistor Stability (ppm / 24hrs – ppm / 1 yr) ± 10 = ± 35Maximum Power Rating (milliwatts) 100Breakdown Voltage (VRMS) 750Operating Temperature Range (°C) -55 to + 75 °CDimensions – inches (mm) 4 x 17 x 3-1/8" (HxWxD) (102 x 432 x 79 mm)Absolute Accuracy Setting*RTD100 ± 0.015%RTD100X ± 0.005

RTD Simulators

Model RTD100XThe RTD100X provides an absolute accuracy of ±0.005% over its entire resistance range. There is no

need to even attempt to calculate or compensate for the error contribution due to contact resistance or“O” resistance because there is no “O” resistance. The unique shunt decade design reduces these errorsto a level of insignificance. When the RTD100X replaces the RTD in the system, any temperature-equiv-alent resistance can be selected on the error-free in-line making it possible to check or calibrate all of theother elements in the system. The usable resistance range of 10 to 1111.11Ω is ideally suited for use withDIN PT100, PT100 ANSI, PT50 and NI120 systems.Model RTD100

The flagship of the GR line prior to the introduction of the RTD100X, the RTD100 is identical to the100X except for its absolute accuracy of ±0.01%.

Page 41: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

Korins Inc. Tel:031-777-1588 Fax:031-777-1587 www.kkkk.com [email protected]

D

Calib

ratio

n Eq

uipm

ent

382

Capacitor and Inductor Standards

Catalog No. Series Value PriceET2065 A 100 pF 7,800,000ET2066 A 100 pF 7,592,000ET2067 A 10 pF 7,376,000ET2068 B 100 µH 5,424,000ET2069 B 1 mH 5,424,000ET2070 B 10 mH 5,424,000ET2071 B 100 mH 5,424,000ET2072 B 1 H 5,424,000ET2073 B 10 H 8,672,000ET2074 C 0.001 µF 1,912,000ET2075 C 0.01 µF 1,944,000ET2076 C 0.1 µF 2,392,000ET2077 C 1.0 µF 4,984,000ET2078 D 1 pF 1,752,000ET2079 D 1.9 pF 2,072,000ET2080 D 10 pF 1,752,000ET2081 D 19 pF 2,072,000

• Ordinal Values• Hermetically Sealed• High-Stability• Low temperature coefficient• Capacitors to 1000 µf

SPECIFICATIONSSeries A Series B

Available Values 10, 100, 1000 pF 100 µH, 1, 10, 100 mH, 1, 10 HCalibration Accuracy ± 5 ppm ± 0.1%; ± 0.25% for 100 mHStability <20 ppm per year; <5 ppm typical ± 0.01% per yearTemperature Coefficient 2 ± 2 ppm/ °C for 100 and 1000 pF ~30 ppm/°C

5 ± 2 ppm/ °C for 10 pFDissipation Factor <10-5 at 1 kHz) —Maximum Voltage 750 V —Maximum Power — 3 WTerminals BNC Connectors (874 optional) 5-way binding posts

SPECIFICATIONSSeries C Series D

Available Values 0.001, 0.01, 0.1, 1.0 µF 1 pF-1000 µF; in 1/1.9/10 sequenceCalibration Accuracy ± 0.02% ± 0.01% to 5 µF; ± 0.02-0.09% to 190 µF; ± 0.4% above 190µFStability ± 0.01% per year better than ±(0.01% + 0.1 pF) per yearTemperature Coefficient + 35 ± 10 ppm/°C 20 to + 110 ppm/°C, depending on valueDissipation Factor <0.0003 at 1 kHz .0002 - .0005 for most values.Maximum Voltage 500 V peak below 10 kHz 500 V peak up to 5 µF; 22 Vrms 10 µF and overTerminals Combination banana plug/binding posts 5-way binding posts

Catalog No. Series Value PriceET2082 D 100 pF 1,752,000 ET2083 D 190 pF 2,072,000ET2084 D 1 nF 1,752,000ET2085 D 1.9 nF 2,072,000ET2086 D 10 nF 1,752,000ET2087 2D 19 nF 2,072,000ET2088 D 100 nF 1,912,000ET2089 D 190 nF 2,072,000ET2090 D 1 µF 4,638,400ET2091 D 1.9 µF 5,102,400ET2092 D 5 µF 5,278,400ET2093 D 10 µF 5,422,400ET2094 D 19 µF 5,758,400ET2095 D 100 µF 6,142,400ET2096 D 190 µF 6,702,400ET2097 D 1000 µF 7,342,400

National Standards Laboratory Grade Working and Reference Standards

Series A Capacitor Series B Inductor Series C Capacitor Series D Capacitance

Page 42: ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 · 2007-11-25 · ºˆ수은이 포함되지 않은 ASTM 정밀 기준 온도계 Catalog No. Range Price MW620 -38/+

669Korins Inc. Tel:031-777-1588 Fax:031-777-1587 www.kkkk.com [email protected]

Moisture / Hum

idity / Dewpoint

H

Relative Humidity Generator and Calibration Chamber

Catalog No. Description PriceGE115HUM Humilab Relative Humidity Generator and Calibration Chamber, 115V AC, 50/60Hz 22,056,000GE230HUM Humilab Relative Humidity Generator and Calibration Chamber, 230V AC, 50/60Hz 22,056,000

• Primary Standard: integrated chilled mirror & plat-inum RTD constantly measure test conditions

• Self-contained operation: equipped with desiccant and water reservoir

• Connect to optional external temperature bath/cir-culator to standardize test conditions

• Connect to external dry compressed air to extenddesiccant life indefinitely

• Record & Document: 0 to 5 VDC, 4 to 20mA outputs & RS-232 digital data

• Fast Response: 10 Minutes for 63% step change& 30 minutes to full stability

• Quality design: stainless steel chamber • Fittings for external dry air, circulation of

temperature controlled water & reservoir drain • Cost effective: ability to calibrate several % RH

Instruments at once• Bright, easy-to-read control panel

The Humilab includes carrying case, NIST trace-able certificate with data and Prostep Software

The HumiLab is a NIST traceable relative hu-midity generator and calibration chamber that iscontinuously monitored by a chilled mirror hy-grometer and precision RTD. The system is waterjacketed for thermal stability and facilitates cost-effective calibrations of humidity sensors, probes,transmitters, recorders and data loggers.

SPECIFICATIONS% RH: 10% to 90% RH at 77°F (25°C)Precision: ± 0.2% RH StabilityVersatility: 10 to 90% RH & 20 to 30°CTemperature range: 60° to 86°F (20° to 30°C)Accuracy: ± 1% RH from 10 to 70% RH and 1.5% RH from

70 to 90% RH± 3°F (0.15°C) dewpoint and 0.3°F (0.15°C) dry bulb at 77°F (25°C)

Analog Output: Two-user scalable 4 to 20mA / 0-5 VDC signals for temperature and humidity

Digital Output: RS232Power: 115 or 230 VAC ± 10%, 50/60 Hz single phase

modelsDigital Interface: Two RS232 ports

• Online Calibration Certificates andStatus Tracking

• Easy Transfer of InstrumentCalibration Data to Excel®, Access®,DBF® and Others