4
FULL RANGE A CLASS ENERGY LABEL Heat pump system » Humidification & » dehumidification in one system Brings fresh, » conditioned air into the room Improved indoor » air quality Inverter technology » incorporated FTXR-E Heating & Cooling Air Conditioners www.daikin.eu Wall Mounted Unit

ΨΥΞΗ ΘΕΡΜΑΝΣΗ ΜΕ URURU SARARA ΤΗΣ DAIKIN

  • Upload
    enicon-

  • View
    241

  • Download
    5

Embed Size (px)

DESCRIPTION

ΨΥΞΗ ΘΕΡΜΑΝΣΗ ΜΕ URURU SARARA ΤΗΣ DAIKIN

Citation preview

Page 1: ΨΥΞΗ ΘΕΡΜΑΝΣΗ ΜΕ URURU SARARA ΤΗΣ DAIKIN

F U L L R A N G E

A C L A S S ENERGY LABEL

Heat pump system »

Humidification & »

dehumidification in one system

Brings fresh, »

conditioned air into the room

Improved indoor »

air quality

Inverter technology »

incorporated

FTXR-E

Heating & CoolingAir Conditioners

w w w . d a i k i n . e u

W a l l M o u n t e d U n i t

ECP010-002.indd 1 1/25/10 12:31:45 PM

Page 2: ΨΥΞΗ ΘΕΡΜΑΝΣΗ ΜΕ URURU SARARA ΤΗΣ DAIKIN

Daikin’s Ururu Sarara split air conditioning unit, with

its unique system, can even heat and cool, humidify

and dehumidify, ventilate and purify the indoor air all

at the same time.

Daikin’s heat pumps are all-in-one heating and cooling

solutions, meaning comfortably warm in winter and

cool in summer. The indoor unit can be used for a pair

application - one indoor unit connected to one

outdoor unit.

The ideal solution for ideal living comfort in all seasons.

Perfect, just the way you like it.

3/4 kW

1/4 kW

4/4 kW +

Inverter technologyThe inverter technology, developed by Daikin is a true

innovation in the area of climate control. The principle is simple:

inverters adjust the power used to suit the actual requirement.

No more, no less. This technology provides you with two concrete

benefits:

ComfortThe inverter repays its investment many times over by improving

comfort. An air conditioning system with an inverter continuously

adjusts its cooling and heating output to suit the temperature in

the room. The inverter shortens system start-up time enabling

the required room temperature to be reached more quickly. As

soon as that temperature is reached, the inverter ensures that it

is constantly maintained.

Energy efficient

Because an inverter monitors and adjusts ambient temperature

whenever needed, energy consumption drops by 30% compared

to a traditional on/off system! (non inverter)

Did you know that ...Air to air heat pumps use 3/4th of energy from renewable sources:

the ambient air. This energy source is renewable and inexhaustible*.

Of course, heat pumps also use 1/4th of electricity to run the

system, but increasingly this electricity can also be generated from

renewable energy sources (solar energy, wind energy, hydropower,

biomass). A heat pump’s efficiency is measured in COP (Coefficient

Of Performance) for heating and EER (Energy Efficiency Ratio) for

cooling. Heat pumps achieve COPs of up to 5.14 (for FTXR28E)!

* EU objective COM (2008)/30

ambient temperature

energy

electricity

Slow start

Temperature remains stableTemperature / Power input

Time

Set temp. Air conditioning with Inverter

Air conditioning without Inverter

Heating operation:

Combining highest efficiency and year-round comfort with a heat pump system

ECP010-002.indd 2 1/25/10 12:31:47 PM

Page 3: ΨΥΞΗ ΘΕΡΜΑΝΣΗ ΜΕ URURU SARARA ΤΗΣ DAIKIN

Design & technological qualityThe Ururu Sarara received the distinguished ‘Good Design Award’,

the unique evaluation criterion for industrial design in Japan.

5 air treatment techniques in 1 system

1. Humidification, even during heatingFor the humidification, called ‘Ururu’ in Japanese, moisture is

absorbed from the outdoor unit and streams into the indoor unit

where it is evenly distributed troughout the room. The advantages

of humidity are preventing sore throats, dry skin and making the

human body feel warmer, even at lower temperatures, thus

reducing heating demand and energy consumption.

2. Dehumidification,

without a drop in temperatureDehumidification, or ‘Sarara’ in Japanese, reduces indoor humidity,

without effecting the room temperature, by mixing cool, dry air

with warm air. So no hot and stuffy rooms any more!

Night set mode:1. saves energy, by preventing

overcooling or -heating during night time

Comfort mode:2. prevents cold or warm air

blowing directly on the body

3D air distribution:3. combination of vertical

and horizontal auto-swing to circulate the air

evenly in even large rooms or corners

Whisper quiet operation:4. the sound of the

indoor units is that low that it can be compared

to rustling leaves

For your personal comfortFollowing features have been incorporated

Temp. : 25°CTemp. : 25°C

Humidity : 80%Hot humid feeling

Humidity : 50%Comfortable feelingSarara

Temp. : 22°CTemp. : 22°C

Humidity : 20%Cold feeling

Humidity : 50%Comfortable feelingUruru

3. Improved indoor air quality thanks

to Daikin’s flash streamer technologyExhaust gases and unpleasant odours are

removed via the outdoor unit. Afterwards

the indoor unit purifies the air on dust, pollen,cigarette smoke

and cooking odours. It also breaks down viruses and moulds.

4. Ventilation,

fresh air even with closed windowsFresh, conditioned air is brought into the room, without cold or

heat loss. The temperature of the incoming air is brought at the

desired level.

5. Heat pump systemThe Ururu Sarara not only offers the possibility of cooling in

summer, it can also provide warmth in cold winters.

ECP010-002.indd 3 1/25/10 12:31:49 PM

Page 4: ΨΥΞΗ ΘΕΡΜΑΝΣΗ ΜΕ URURU SARARA ΤΗΣ DAIKIN

Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende

Daikin products are distributed by:

The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V.

FSC

ECPEN10-002Daikin Europe N.V. participates in the Eurovent Certification Programme for Air Conditioners (AC), Liquid Chilling Packages (LCP) and Fan Coil Units (FC); the certified data of certified models are listed in the Eurovent Directory. Multi units are Eurovent certified for combinations up to 2 indoor units.

Daikin’s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste.

The

pres

ent p

ublic

atio

n su

pers

edes

ECP

EN09

-002

.Pr

inte

d on

non

-chl

orin

ated

pap

er. P

repa

red

by L

a M

ovid

a, B

elgi

um

Resp

. Ed.

: Dai

kin

Euro

pe N

.V., Z

andv

oord

estr

aat 3

00, B

-840

0 O

oste

nde

Outdoor UnitRXR28,42,50E

Infrared Remote ControlARC447A1

Indoor UnitFTXR28,42,50E

Heating & CoolingINDOOR UNITS FTXR28E FTXR42E FTXR50E

Capacitycooling min~nom~max kW 1.55~2.8~3.60 1.55~4.2~4.60 1.55~5.0~5.50heating min~nom~max kW 1.30~3.6~5.00 1.30~5.1~5.60 1.30~6.0~6.20

Power inputcooling min~nom~max kW 0.25~0.56~0.80 0.26~1.05~1.32 0.26~1.46~1.80heating min~nom~max kW 0.22~0.70~1.41 0.22~1.18~1.60 0.23~1.51~1.77

EER cooling 5.00 4.00 3.42COP heating 5.14 4.32 3.97

Energy labelcooling Aheating A

Annual energy consumption cooling kWh 280 525 730Dimensions height x width x depth mm 209x890x305Weight kg 14Front panel colour White

Air flow ratecooling H / M / L / SL m3/min 11.1/8.8/6.5/5.7 12.4/9.6/6.8/6.0 13.3/10.3/7.3/6.5heating H / M / L / SL m3/min 12.4/9.8/7.3/6.5 12.9/10.2/7.7/6.8 14.0/11.1/8.3/7.3

Sound pressure levelcooling H / M / L / SL dBA 39/33/26/23 42/35/27/24 44/37/29/26heating H / M / L / SL dBA 41/35/28/25 42/36/29/26 44/38/31/28

Sound power levelcooling dBA 55 58 60heating dBA 57 58 60

Power supply 1~/ 220-240V /50HzRemote control infrared ARC447A1

OUTDOOR UNITS RXR28E RXR42E RXR50EDimensions height x width x depth mm 693x795x285Weight kg 48Compressor type Hermetically sealed swing

Sound powercooling dBA 60 62heating dBA 60 62 64

Refrigerant type R-410AAdditional refrigerant charge kg/m Chargeless

Operation rangecooling min~max °CDB -10~43heating min~max °CWB -20~18

Piping connectionsliquid mm ø6.35gas mm ø9.52drain ID mm ø18

Sound pressure cooling High dBA 46 48heating High dBA 46 48 50

Maximum piping length m 10Maximum installation height difference m 8Power supply 1~ / 220~240V / 50Hz

Notes: 1) Energy label: scale from A (most efficient) to G (least efficient) - 2) Annual energy consumption: based on average use at 500 running hours per year full load (= nominal conditions). - 3) V1 = 1=, 220-240V, 50Hz - 4) Nominal cooling capacities are based

please refer to the technical data books) - 8) The sound power level is an absolute value indicating the “power” which a sound source generates.

ECP010-002.indd 4 1/25/10 12:31:55 PM

Cert no. SGS-COC-006250

ECPEN10-002