02 Malaysian GBI

Embed Size (px)

Citation preview

  • 8/2/2019 02 Malaysian GBI

    1/34

    10/14/2009

    1

    Malaysian Green Building Index

    IEN Consultants Sdn. Bhd

    www.ien.com.m

    16 September 2009

    Introduction to GBI

  • 8/2/2019 02 Malaysian GBI

    2/34

    10/14/2009

    2

    Sustainable Site Planningand Management

    WaterInnovation c ency

    Energy EfficiencyIndoor

    EnvironmentQuality

    Materials & Resources

    GBI address 2 Types of Building

    on- es ent a

    Residential100 points score sheet

  • 8/2/2019 02 Malaysian GBI

    3/34

    10/14/2009

    3

    50-65Certified

    Levels of GBI Ratings for NRNC

    86+Platinum

    76-85Gold

    66-75Silver

    GBI Categories Max. Points

    GBI Overall Points Score for Non-Residential

    Indoor Environmental Quality 21

    Site Planning & Mgt. 16

    Materials and Resources 11

    Water Efficiency 10

    Innovations 7

  • 8/2/2019 02 Malaysian GBI

    4/34

    10/14/2009

    4

    GBI Criteria Non ResidentialEnergy Efficiency 35 pts

    EE1: Minimum EE Performance

    OTTV 50, RTTV 25 Provision of Energy Management Control

    System

    1 Point

  • 8/2/2019 02 Malaysian GBI

    5/34

    10/14/2009

    5

    EE2: Lighting Zoning All individual or enclosed spaces to be individually

    switched; and the size of individually switchedlighting zones shall not exceed 100m for 90% of the NLA; with switching clearly labelled and easilyaccessible by building occupants.

    Provide auto-sensor controlled lighting inconjunction with daylighting strategy for all

    perimeter zones and daylit areas, if any Provide motion sensors or equivalent tocomplement lighting zoning for at least 25% NLA

    3 Points

    EE3: Electrical sub-metering &Tenant sub-meteringProvide sub-metering for all energy uses of > 100kVa; with

    se arate sub-meterin for li htin and se aratel for power at each floor or tenancy, whichever is smaller.

    1 Point

  • 8/2/2019 02 Malaysian GBI

    6/34

    10/14/2009

    6

    EE4: Renewable EnergyWhere 0.5 % or 5 kWp whichever is thegreater, of the total electricity consumptionWhere 1.0 % or 10 kWp whichever is thegreater, of the total electricity consumption 3

    Where 1.5 % or 20 kWp whichever is thegreater, of the total electricity consumption 4

    5 Points

    .greater, of the total electricity consumption 5

    EE5 Advanced EE Performance

    BEI < 150 kWh/m 2.yr 2,

    BEI < 130, OR 5BEI < 120, OR 8BEI < 110, OR 10BEI < 100, OR 12

    15 Points

    BEI < 90 15

  • 8/2/2019 02 Malaysian GBI

    7/34

    10/14/2009

    7

    EE6 Enhanced Commissioning1. Conducting at least one commissioning design review during thedetail design stage.

    2. Developing and incorporating commissioning requirements into thetender documents.3. Developing and implementing a commissioning plan.4. Verifying the installation and performance of the systems to becommissioned.5. Reviewing contractor submittals applicable to systems beingcommissioned for compliance.

    .the information needed to understand and optimally operate thecommissioned systems.7. Verifying that the requirements for training operating personnel andbuilding occupants are completed.

    3 Points

    EE7: Post OccupancyCommissioning1. Design engineer shall review all tenancy fit-out plans to

    ensure ori inal desi n intent is not com romised and upon completion of the fit-out works, verify and fine-tune the installations to suit.

    2. Within 12 months of practical completion (or earlier if there is at least 50% occupancy), the CxS shall carryout a full post/re-commissioning of the building's energyrelated s stems to verif that their erformance is sustained in conjunction with the completed tenancy fit-outs.

    2 Points

  • 8/2/2019 02 Malaysian GBI

    8/34

    10/14/2009

    8

    EE8: EE Verification1. Use Energy Management System to

    mon or an ana yse energy consump onincluding reading of sub-meters, AND

    2. Fully commission EMS includingMaximum Demand Limiting programmewithin 12 months of ractical com letion

    (or earlier if there is at least 50%occupancy).

    2 Points

    EE9: Sustainable Maintenance1. At least 50% of permanent building maintenance team to

    be on-board one (1) to three (3) months before practicalcompletion and to fully participate (to be specified incontract conditions) in the Testing & Commissioning of all building energy services.

    2. Provide for a designated building maintenance office thatis fully equipped with facilities (including tools andinstrumentation) and inventory storage.

    3. Provide evidence of documented plan for at least 3-year facility maintenance and preventive maintenance budget(inclusive of staffing and outsourced contracts).

    3 Points

  • 8/2/2019 02 Malaysian GBI

    9/34

    10/14/2009

    9

    Indoor Environment Quality

    21 pts

    EQ1: Minimum IAQPerformanceMeet the minimum requirements of

    ven a on ra e n . : or the local building code whichever is themore stringent.

    1 Point

  • 8/2/2019 02 Malaysian GBI

    10/34

    10/14/2009

    10

    EQ2: Environmental Tobacco

    Smoke (ETS) ControlProhibit smoking in the building, AND Locate

    any ex er or es gna e smo ng areas aleast 10m away from entries, outdoor air intakes and operable windows.

    1 Point

    EQ3: Carbon Dioxide Monitoringand ControlInstall carbon dioxide (CO 2) monitoring and

    con ro sys em w a eas one 2sensor at all main return points on eachfloor t o facilitate continuous monitoringand adjustment of outside air ventilationrates to each floor, and ensureindependent control of ventilation rates tomaintain CO 2 level < 1,000 ppm

    1 Point

  • 8/2/2019 02 Malaysian GBI

    11/34

    10/14/2009

    11

    EQ 4: Indoor Air Pollutants1. Low VOC for Paint & Coating, Carpet &

    oor ng an es ve ea an2. Products with no Added Urea

    Formaldehyde. Composite wood & agrifiber products, MDF,

    l wood etc..

    Laminating adhesives Insulation foam Etc.

    2 Points

    EQ5: Mould Prevention

    To demonstrate design will prevent moldgrow .

    AHU Design parameters Positive pressure building Prevention of infiltration Etc.

    1 Point

  • 8/2/2019 02 Malaysian GBI

    12/34

    10/14/2009

    12

    EQ6: Thermal Comfort: Design

    & Controllability of Systems. .

    2. 50% building occupants have controlover their individual comfort condition.

    2 Points

    EQ7: Air Change Effectiveness

    The ventilation systems are designed toac eve an o . w en measurein accordance with ASHRAE 129-1997:Measuring air change effectiveness where

    ACE is to be measured in the breathingzone (nominally 1.0 m from finished floor level)

    1 Point

  • 8/2/2019 02 Malaysian GBI

    13/34

    10/14/2009

    13

    EQ8: DaylightingDemonstrate that 30% of the NLA has a

    ay g ac or n e range o . .as measured at the working plane, 800mmfrom floor level 1 point

    Demonstrate that 50% of the NLA has ada li ht factor in the ran e of 1.0 3.5%

    as measured at the working plane, 800mmfrom floor level 2 points

    2 Points

    EQ9: Daylight Glare Control a) Eliminate glare from all direct sun penetration and

    keep horizontal workspace lux level below 2000; b Eliminate glare rom di use sky radiation or occupant

    workspace at viewing angles of 15 to 60 from the

    horizontal at eye level (typically 1.2m from floor level) c) Control with an automatic monitoring system (for

    atrium and windows with incident direct sun light only -not applicable for fixed blinds/screens); AND d) Equipw a manua overr e unc on access e y occupan s(not applicable for fixed blinds/screens)

    1 Point

  • 8/2/2019 02 Malaysian GBI

    14/34

    10/14/2009

    14

    EQ10: Electric Lighting LevelsDemonstrate that office lighting design

    ma n a ns a um nance eve o no morethan specified in MS1525:2007 for 90% of NLA as measured at the working plane(800 mm above the floor level).

    1 Point

    EQ11: High Frequency Ballasts

    Install high frequency ballasts in fluorescentum na res over a m n mum o o .

    1 Point

  • 8/2/2019 02 Malaysian GBI

    15/34

    10/14/2009

    15

    EQ12: External ViewsDemonstrate that 75% of the NLA has a

    rec ne o s g roug v s on g az ng aa height of 1.2m from floor level. - 2 points

    2 Points

    EQ13: Internal Noise Levels

    Within the entire baseline building generalo ce, space no se rom e u ngservices does not exceed 40dBAeq.

    Or Within the baseline building office space, the

    open plan and not exceed 40dBAeq for closed offices

    1 Point

  • 8/2/2019 02 Malaysian GBI

    16/34

    10/14/2009

    16

    EQ 14: IAQ Before & During

    Occupancy1. Perform Flush Out before Occupancy.

    ac or m n ac n t a ays ooccupancy or

    10 ach for 15 min & 1 ach initial 7 days of occupancyif EQ4 is met (Low VOC and no formaldehyde used)or

    Conduct IAQ testing

    2. Permanent air flushing system of at least10 ach is installed during occupancystage.

    2 Points

    EQ15: Post Occupancy ComfortSurvey: Verification1. Within 12 months, conduct occupant

    survey on erma , v sua an acous ccomfort. And

    2. Develop action plan if survey resultindicate that > 20% of occupants aredissatisfied with overall comfort.

    2 Points

  • 8/2/2019 02 Malaysian GBI

    17/34

    10/14/2009

    17

    Sustainable Site Planning &

    Management 16 pts

    SM1: Site SelectionDo not develop building, hardscape, road or parking area on a site or part of a site that meet any one of the following criteria:-

    a) Prime farmland

    b) Forest reserve or State Environmental Protection Zones

    c) Within 30 m of any wetlands

    d) Previously undeveloped land that is within 30 m of Mean High Water Spring(MHWS) sea level which supports or could support wildli fe or recreational use

    e) Previously undeveloped land that is within 20 m of lake, river, stream and tributary.

    f) Land which prior to acquisition for the project was public parkland, unless land of equal or greater value as parkland is provided.

    1 Point

  • 8/2/2019 02 Malaysian GBI

    18/34

    10/14/2009

    18

    SM2: Brownfield RedevelopmentReduce pressure on undeveloped land by

    re a a ng amage s es.Typically, rubbish tips, former mining land,

    old factory sites, etc.

    1 Point

    SM3: Development Density &Community ConnectivityConstruct a new building or renovate an

    ex s ng u ng on a prev ous ydeveloped site AND within 1 km of aresidential zone or neighbourhood with anaverage density of 25 units per hectare net(10 units per acre net) AND within 1 km of at least 10 Basic Services AND withpedestrian access between the buildingand the services.

    1 Point

  • 8/2/2019 02 Malaysian GBI

    19/34

    10/14/2009

    19

    SM4: Environment Management

    Open Space Reduce by 25%, the development footprint

    (defined as the total area of the buildingfootprint, hardscape, access road andparking) and/or provide vegetated open spacewithin the project boundary to exceed the

    site.

    1 Point

    SM5: Earthworks - Construction Activity Pollution ControlReduce pollution from construction activities

    y con ro ng so eros on, wa erwaysedimentation and airborne dustgeneration:-

    1 Point

  • 8/2/2019 02 Malaysian GBI

    20/34

    10/14/2009

    20

    SM6: QLASSIC Achieve a minimum score of 70% on

    ass c

    1 Point

    SM7: Workers Site Amenities

    a) Proper accommodation for construction workers at the.

    b) Prevent pollution of storm sewer or receiving stream byhaving proper septic tank.

    c) Prevent polluting the surrounding area from open

    1 Point

    burning and proper disposal of domestic waste.

    d) Provide adequate health and hygiene facilities for workers on site.

  • 8/2/2019 02 Malaysian GBI

    21/34

    10/14/2009

    21

    SM8: Public Transportation

    AccessLocate project within 1 km of an existing, or

    p anne an un e , commu er ra , grail or subway station.

    Or Locate project within 500 m of at least one

    .

    1 Point

    SM9: Green Vehicle Priority

    Preferred Parking Spaces for Low Emittingan ue c en e c es or o uTime Equivalent (FTE).

    1 Point

  • 8/2/2019 02 Malaysian GBI

    22/34

    10/14/2009

    22

    SM10: Parking CapacitySize parking capacity to meet but not

    excee e m n mum oca zon ngrequirements.

    AndProvide preferred parking for carpools or

    spaces.

    1 Point

    SM11: Stormwater Design Quantity and Quality ControlExisting imperviousness is 50%

    Meet MASMA.

    Existing imperviousness is > 50%25% better than MASMA.

    90% of the average annual rainfall to becaptured & treated before discharge fromsite.

    1 Point

  • 8/2/2019 02 Malaysian GBI

    23/34

    10/14/2009

    23

    SM12: Greenery & Roof A) 50% of the site hardscape

    To be shaded within 5 years of occupancyOr Paving materials SRI > 71Or Open grid pavement system.

    B) Roof

    SRI > 75Or vegetated roof > 50% area.

    2 Points

    SM13: Building User Manual

    Provide a Building User Manual thatocumen s pass ve an ac ve ea ures

    that should not be downgraded.

    1 Point

  • 8/2/2019 02 Malaysian GBI

    24/34

    10/14/2009

    24

    Materials & Resources

    11 pts

    MR1: Materials reuse and selection

    Reuse building materials 2% of total material cost value 1 pt

    5% of total material cost value 2 pts

    2 Points

  • 8/2/2019 02 Malaysian GBI

    25/34

    10/14/2009

    25

    MR2: Recycled content materials

    Recycled Contents in Building Materials 10% of total material cost value 1 pt 30% of total material cost value 2 pts

    Pre-consumer (worth 50%) Post-consumer recycled contents (worth

    2 Points

    MR3: Regional Materials

    Use building materials or products that haveeen ex rac e , arves e or recovere ,

    as well as manufactured, within 500km of the project site for > 20% (based on cost)of the total material value

    1 Point

  • 8/2/2019 02 Malaysian GBI

    26/34

    10/14/2009

    26

    MR4: Sustainable Timber

    Where > 50% of wood-based materialsan pro uc s use are cer e .Compliance with Malaysian Timber Certification Council & Forest Research Stewardship requirements.

    1 Point

    MR5: Storage & Collection of recyclablesDuring Construction, provide dedicated

    area s an s orage or co ec on o non-hazardous materials for recycling, AND

    During Building Occupancy, providepermanent recycle bins .

    1 Point

  • 8/2/2019 02 Malaysian GBI

    27/34

  • 8/2/2019 02 Malaysian GBI

    28/34

    10/14/2009

    28

    GBI Criteria Non ResidentialWater Efficiency 10 pts

    WE1: Rainwater Harvesting

    Rainwater harvesting that leads to >15%re uc on n po a e wa er consump on 1 point

    Rainwater harvesting that leads to >30%

    2 points

    2 Points

  • 8/2/2019 02 Malaysian GBI

    29/34

    10/14/2009

    29

    WE2: Water Recycling

    Treat and recycle >10% wastewater leadingo re uc on n po a e wa er consump on;

    1 pt

    Treat and recycle >30% wastewater leading

    2 pts

    2 Points

    WE3: Water Efficient -Irrigation/LandscapingReduce potable water consumption for

    an scape rr ga on y > e.g. rouguse of native or adaptive plants to reduceor eliminate irrigation requirement; 1 pt

    irrigation; 2 pts.

    2 Points

  • 8/2/2019 02 Malaysian GBI

    30/34

    10/14/2009

    30

    WE4: Water Efficient FittingsEncourage reduction in potable water

    consump on roug use o e c endevices :-

    Reduce annual potable water consumptionby >30%; 1 pt

    Reduce annual potable water consumptionby >50%; 2 pts

    2 Points

    WE5: Metering & Leak DetectionSystemUse of sub-meters to monitor and manage

    ma or wa er usage or coo ng owers,irrigation, kitchens and tenancy use; 1 pt

    Link all water sub-meters to EMS to facilitate

    2 Points

  • 8/2/2019 02 Malaysian GBI

    31/34

    10/14/2009

    31

    Innovation

    7 pts

    IN1: Innovation in Design &Environmental Design Initiatives

    . y y u u ybut not addressed by this GBI RatingSystem.

    Max 6 Points

  • 8/2/2019 02 Malaysian GBI

    32/34

    10/14/2009

    32

    IN2: Green Building Index

    Facilitator At least one principal participant of the

    pro ec eam s a e a reen u ngIndex Facilitator who is engaged at theonset of the design process untilcompletion of construction and GreenBuilding Index certification is obtained.

    1 Point

    Thats It! 100 Points!

  • 8/2/2019 02 Malaysian GBI

    33/34

    10/14/2009

    33

    GBI Assessment Process

    Application GBI Certifier ReviewGBI Certifier

    Review

    Registration

    Appoint ProjectCoordinator/ GBI

    Facilitator

    GSB issuesprovisional GBI

    Certificate

    GBI Certifier submit to GSB

    GBI Certifier submit CVA to

    GSB

    GSB issues GBICertification

    esgn AssessmentSubmission

    u m t or upon completion

    of project

    GSB Greenbuildingindex Sdn. Bhd.GBI Green Building Index

    EnergyConsultant Architect

    Owner

    ucontractors

    ContractorMechanical

    Engineer

    vEngineer

    GBI FacilitatorWorking Togetherto Achieve the Goal

    InteriorDesigner

    LandscapeArchitect

    ElectricalEngineer

  • 8/2/2019 02 Malaysian GBI

    34/34

    10/14/2009

    PeopleEnvironment

    Corporate SocialResponsibility

    Cli t Chlimate Change

    THANKS!

    Economics