1.1005.54.Xxx HT Geber Compact Engl 1

Embed Size (px)

DESCRIPTION

wind vane

Citation preview

  • THE

    WOR

    LD O

    F W

    EATH

    ER D

    ATA

    - TH

    E W

    ORLD

    OF

    WEA

    THER

    DAT

    A - T

    HE W

    ORLD

    OF

    WEA

    THER

    DAT

    A

    Instruction for use

    020891/06/13

    Hygro-ThermoTransmitter-compact 1.1005.54.xxx

    1.1005.64.xxx

    ADOLF THIES GmbH & Co. KG Hauptstrae 76 37083 Gttingen Germany Box 3536 + 3541 37025 Gttingen Phone +49 551 79001-0 Fax +49 551 79001-65 www.thiesclima.com [email protected]

    1.1005x4.0xx/1xx/4xx/8xx...

    1.1005.54.2xx/3xx/4xx/9xx...

    1.1005.x4.7xx...

  • Safety Instructions Before operating with or at the device/product, read through the operating instructions.

    This manual contains instructions which should be followed on mounting, start-up, and operation. A non-observance might cause: - failure of important functions - endangerment of persons by electrical or mechanical effect - damage to objects

    Mounting, electrical connection and wiring of the device/product must be carried out only by a qualified technician who is familiar with and observes the engineering regulations, provisions and standards applicable in each case.

    Repairs and maintenance may only be carried out by trained staff or Adolf Thies GmbH & Co. KG. Only components and spare parts supplied and/or recommended by Adolf Thies GmbH & Co. KG should be used for repairs.

    Electrical devices/products must be mounted and wired only in a voltage-free state.

    Adolf Thies GmbH & Co KG guarantees proper functioning of the device/products provided that no modifications have been made to the mechanics, electronics or software, and that the following points are observed:

    All information, warnings and instructions for use included in these operating instructions must be taken into account and observed as this is essential to ensure trouble-free operation and a safe condition of the measuring system / device / product.

    The device / product is designed for a specific application as described in these operating instructions.

    The device / product should be operated with the accessories and consumables supplied and/or recommended by Adolf Thies GmbH & Co KG .

    Recommendation: As it is possible that each measuring system / device / product may,under certain conditions, and in rare cases, may also output erroneous measuring values, it is recommended using redundant systems with plausibility checks for security-relevant applications.

    Environment As a longstanding manufacturer of sensors Adolf Thies GmbH & Co KG is committed to the

    objectives of environmental protection and is therefore willing to take back all supplied products governed by the provisions of "ElektroG" (German Electrical and Electronic Equipment Act) and to perform environmentally compatible disposal and recycling. We are prepared to take back all Thies products concerned free of charge if returned to Thies by our customers carriage-paid.

    Make sure you retain packaging for storage or transport of products. Should packaging however no longer be required, please arrange for recycling as the packaging materials are designed to be recycled.

    Documentation Copyright Adolf Thies GmbH & Co KG, Gttingen / Germany Although these operating instruction has been drawn up with due care, Adolf Thies GmbH & Co KG can

    accept no liability whatsoever for any technical and typographical errors or omissions in this document that might remain.

    We can accept no liability whatsoever for any losses arising from the information contained in this document.

    Subject to modification in terms of content.

    The device / product should not be passed on without the/these operating instructions.

    2 - 14 020891/06/13

  • Contents

    1 Models available ....................................................................................................................... 4

    2 Application ................................................................................................................................ 5

    3 Mounting ................................................................................................................................... 6

    4 Maintenance ............................................................................................................................. 6

    5 Connection Diagrams ............................................................................................................... 6

    6 Technical Data ........................................................................................................................ 11

    7 Accessories / spare part (optional) .......................................................................................... 12

    8 EC-Declaration of Conformity ................................................................................................. 13

    3 - 14 020891/06/13

  • 1 Models available

    Order-No. Measuring Range

    Humidity Output

    Temperature Output

    Operating Voltage

    Sensor protective

    filter

    Construction / Connection

    1.1005.54.000 0...100% r. F. +70C

    0...1 V Pt 100 6...30V DC ZE20 Cable gland (Ms), 5m cable

    1.1005.54.150 0...100% r. F. +70C

    0...1 V Pt 100 6...30V DC ZE20 Cable gland (Ms), 25 m cable

    1.1005.54.160 0...100 % r. F. -30...+70C

    0...1 V 0...1 V 6...30 VDC ZE20 Cable gland (Ms), 10m cable

    1.1005.54.161 0...100 % r. F. -30...+70C

    0...10 V 0...10 V 15...30V DC ZE20 Cable gland (Ms), 5m cable

    1.1005.54.173 0...100 % r. F. -30...+70C

    0...5 V 0...5 V 10...30V DC ZE20 Cable gland (Ms), 5m cable

    1.1005.54.241 0...100 % r. F. -30...+70C

    4...20mA 4...20 mA 12..30V DC* ZE20 Connecting head (Al), Screw clamp Cable gland

    1),

    5m cable

    1.1005.54.300 0...100% r. F. +70C

    0...1 V Pt 100 6...30V DC ZE21 Connecting head (Al), screw clamp, Cable gland

    2) from

    stainless steel, 5m cable

    1.1005.54.441 0...100 % r. F. -40...+60C

    4...20mA 4...20 mA 12..30V DC* ZE20 Connecting head (Al), screw clamp, Cable gland

    1),

    5m cable

    1.1005.54.448 0...100 % r. F. -40...+60C

    4...20mA 4...20 mA 12..30V DC* ZE20 Connecting head (Al), screw clamp, Cable gland

    1),

    8m cable

    1.1005.54.460 0100 % r.F. -40+60C

    01 V 01 V 630 V DC ZE20 Cable gland (Ms), 5m cable

    1.1005.54.461 0...100 % r. F. -40...+60C

    0...10 V 0...10 V 15...30V DC ZE20 Cable gland (Ms), 5m cable

    1.1005.54.700 0...100% r. F. +70C

    0...1 V Pt 100 6...30V DC ZE20 Plug

    1.1005.54.701 0...100% r. F. +70C

    0...1 V Pt 100 6...30V DC ZE20 Plug with mating plug

    1.1005.54.760 0...100 % r. F. -30...+70C

    0...1 V 0...1 V 6...30 VDC ZE20 Plug with mating plug

    1.1005.54.761 0...100 % r. F. -30...+70C

    0...10 V 0...10 V 15...30V DC ZE20

    1.1005.54.762 0100 % r. F. -40+60C

    010 V 010 V 1530V DC ZE20 Plug with mating plug

    1.1005.54.773 0...100 % r. F. -30...+70C

    0...5 V 0...5 V 10...30V DC ZE20 Plug with mating plug

    1.1005.54.800 0...100% r. F. +70C

    0...1 V Pt 100 6...30V DC ZE20 Cable gland (Ms), 10m cable

    4 - 14 020891/06/13

  • 1.1005.54.941 0...100 % r. F. -5...+50C

    4...20mA 4...20 mA 12..30V DC* ZE20 Connecting head (Al), Screw clamp Cable gland

    1),

    5m cable

    1.1005.64.000 0...100% r. F +70C

    0...1 V Pt 100 6...30V DC ZE21 Cable gland (Ms) 5m cable

    1.1005.64.161 0...100 % r. F. -30...+70C

    0...10 V 0...10 V 15...30V DC ZE21 Cable gland (Ms), 5m cable

    1.1005.64.173 0...100 % r. F. -30...+70C

    0...5 V 0...5 V 10...30V DC ZE21 Cable gland (Ms), 5m cable

    1.1005.64.241 0...100 % r. F. -30...+70C

    4...20mA 4...20 mA 12..30V DC* ZE21 Connecting head (Al), Screw clamp Cable gland

    1),

    5m cable

    1.1005.64.701 0...100% r. F +70C

    0...1 V Pt 100 6...30V DC ZE21 Plug with mating plug

    * see diagram RL 1) M16x1,5, Material: brass nickel-plated, clamping range: 3-7mm 2) M16x1,5, Material: stainless steel 1.4571, clamping range: 4-6,5mm

    2 Application

    The Hygro-Thermo Transmitters of our compact series are designed to measure relative humidity, the temperature of the air and other non-aggressive gases.

    The use of capacitive humidity sensors is a guarantee for:

    a high degree of long-term stability

    nearly linear characteristics

    good dynamic behaviour

    dewing stability

    low temperature coefficients

    low hysteresis

    The hygro-thermo transmitter is equipped with a protective filter for the sensors, depending on model (see models available).

    Type: Membrane-filter with gauze ZE20 (order-no. 1.1005.54.901) for protection against dust in case of field application.

    Type: sinter-filter-ZE21 made of stainless steel (order-no. 1.1005.54.902) for protection against dust, sand and high wind velocities (>5 m/s).

    Remark: For filed work, it is advisable to use a Weather and Thermal Radiation Shield. It is optionally available as accessory.

    5 - 14 020891/06/13

  • 3 Mounting

    For correct measurements, the Hygro-Thermo Transmitter should be mounted at a site in the room, which is representative of the climate within the room. The mounting position itself is arbitrary. Mount the sensor such that water cannot penetrate the inside of the sensor. Dewing and sprinkling water do not damage the sensor.

    Moreover, please make sure to keep the operating voltages as well as a good recirculation ventilation of the instrument. Deviations might lead to measurement errors (for example: due to instrument warming).

    Preferably, the sensor should be mounted vertically facing downwards to a wall (indoor application), and should be mounted horizontally facing backwards in canals.

    4 Maintenance

    The Hygro-Thermo Transmitter is supplied already adjusted and its characteristics remain stable for years. Dust does not damage the humidity sensor but does influence the dynamic behaviour negatively. If the instrument is very dirty, the sensor element can be cleaned or carefully rinsed in distilled water. Make sure you do not touch the highly-sensitive sensor element. Before cleaning the sensor elements please remove the protecting filter; it should be cleaned, as well or should be replaced.

    Attention: The instrument housing with the electronics included should be opened only in the factory.

    5 Connection Diagrams

    1.1005.54.000 1.1005.54.150 1.1005.54.300 1.1005.54.800 1.1005.64.000

    1 2 875 6 9 10

    Hygro -Thermo Transmitter - compact1. 1005. x4. xx0

    Pg / Cable

    Earth

    Shield

    H+ T1 T2T2T10...1V

    = 0...100%rel.H. Output

    Power Supply6...30 V DC Pt 100 Output

    6 - 14 020891/06/13

  • 1.1005.54.160 1.1005.54.460

    1.1005.54.161 1.1005.54.461 1.1005.64.161

    1.1005.54.173 1.1005.64.173

    1 2 653 4

    Hygro -Thermo Transmitter - compact1. 1005. x4. 161 / 461

    Pg / Cable

    H+ T+Power Supply15...30 VDC

    0...10 VTemperatureOutput

    0...10 V= 0...100 %rel.H.Output

    Shield

    Earth

    1 2 653 4

    Hygro -Thermo Transmitter - compact1. 1005. 54. 173

    Pg / Cable

    H+ T+Power Supply10...30 VDC

    0... 5 VTemperatureOutput

    0...5 V= 0...100 %rel.H.Output

    Shield

    Earth

    1 2 653 4

    Hygro -Thermo Transmitter - compact1. 1005. 54. 160 / 460

    Pg / Cable

    H+ T+Power Supply6...30 VDC

    0...1 VTemperatureOutput

    0...1 V= 0...100 %rel.H.Output

    Shield

    Earth

    7 - 14 020891/06/13

  • 1.1005.54.241 1.1005.54.441 1.1005.54.448 1.1005.54.941 1.1005.64.241

    12 V 30 V20 V

    1200 W

    800 W

    400 W

    0 WRL

    Diagram RL as a function of power supply

    Pg / Cable

    431 2

    Hygro -Thermo Transmitter - compact1.1005. 54. 241 / 441 / 941 / 448

    Earth

    Shield

    H+ H- T-T+

    4...20 mA= 0 ...100 % r.H.

    4...20 mA= - 30...+ 70 C (...241)= - 40...+ 60 C (...441/ 448)= - 5...+ 50 C (...941)

    Power Supplysee diagram

    8 - 14 020891/06/13

  • 1.1005.54.760

    3 2 1 4 7 5

    Hygro - Thermo - Geber / Transmitter - compact 1. 1005. 54. 760

    Stecker / Plug

    H+ + - T+ Betriebsspg. Power Supply 630 VDC

    01V Temperatur

    Ausgang/Output

    01V = 0100% rel.F. / r.H.

    Ausgang/Output

    Schirm Shield

    Erde Earth

    6

    Position of pins

    12

    3 45

    67

    1.1005.54.761 1.1005.54.762

    3 2 1 4 7 5

    Hygro - Thermo - Geber / Transmitter - compact 1. 1005. 54.761 / 762

    Stecker / Plug

    H+ + - T+ Versorgung Power Supply 1530 VDC

    010V Temperatur

    Ausgang/Output

    010V = 0100% rel.F. / r.H.

    Ausgang/Output

    Schirm Shield

    Erde Earth

    6

    Position of pins

    12

    3 45

    67

    1.1005.54.773

    3 2 1 4 7 5

    Hygro - Thermo - Geber / Transmitter - compact 1. 1005. 54. 773

    Stecker / Plug

    H+ + - T+ Betriebsspg. Power Supply 1030 VDC

    05V Temperatur

    Ausgang/Output

    05V = 0100% rel.F. / r.H.

    Ausgang/Output

    Schirm Shield

    Erde Earth

    6

    Position of pins

    12

    3 45

    67

    9 - 14 020891/06/13

  • 1.1005.54.700 1.1005.54.701 1.1005.64.701

    Hygro - Thermo - Geber / Transmitter - compact

    1. 1005. x4. 70x

    Stecker / Plug

    = 0100%

    Schirm Shield

    3 2 5 1 4 7 6

    H+ + - Betriebsspg. Power Supply 630 VDC

    01V

    rel.F. / r.H. Ausgang/Output

    Erde Earth

    T1 T2 T2 T1

    Pt 100 Ausgang / Output

    Position of pins

    12

    3 45

    67

    Fig. with additional cable assembly

    0.1005.54.904

    Hygro - Thermo - Geber / Transmitter - compact 1. 1005. x4. 70x

    Stecker / Plug

    Schirm Shield

    3 2 5 1 4 7 6

    1 2 9 8 5 7 10 6

    H+ + - Versorgung Power Supply 6 ... 30 VDC

    0 - 1V = 0-100% rel.F. / r.H.

    Ausgang/Output

    Erde Earth

    T1 T2 T2 T1

    Pt 100 Ausgang / Output

    H+ + - Versorgung Power Supply 6 ... 30 VDC

    0 - 1V = 0-100% rel.F. / r.H.

    Ausgang/Output

    Erde Earth

    T1 T2 T2 T1

    Pt 100 Ausgang / Output

    10 - 14 020891/06/13

  • 6 Technical Data

    Humidity Measuring element Capacitive Measuring range 0...100 % rel. humidity Deviation (mr 5...95% rel.h. at 10...40 C) 2 % rel. humidity Add. Error (40C) < 0,1%/K Response Time (T 90) < 20 s (at v = 1.5 m/s) w/o filter Response Time (T 90) < 1.5 min. (at v = 1.5 m/s) with Membrane filter

    ZE 20 Response Time (T 90) < 1.5 min. (at v = 1.5 m/s) with Sinter filter ZE 21 Temperature Measuring element Pt 100 Class B, 1/3 DIN tolerance Measuring range See models available Deviation with output Pt 100, 1/3 DIN 0.1 K with output 0-10 V 0.2 K with output 4-20 mA 0.3 K Add. error (40C) 0.0073 K/K Response time (T 90) < 20 s (at v = 1.5 m/s) w/o filter Response time (T 90) < 1.5 min. (at v = 1.5 m/s) with Membrane filter

    ZE 20 Response time (T 90) < 1.5 min. (at v = 1.5 m/s) with Sinter filter ZE 21 Additional Specifications Ambient temperature -40...+80C Degree of protection sensor IP 30 Degree of protection electronics, connecting head IP 65 Operating voltage I-output 12...30 V DC U-output (0...10 V) 1530 V DC U-output (0...5 V) 1030 V DC U-output (0...1 V) 6...30 V DC Load resistor I-output See diagram RL U-output (0...10 V / 0...5 V) 10 k U-output (0...1 V) 2 k Instrument current requirements Humidity/Temperature (0..10V / 0..5V) < 5 mA Humidity(0...1V) < 1 mA Dimension to model 1005.54(64).000 / 150 / 160 / 161 / 173 / 460 /461 / 800 Diameter 20 mm Shaft length 122 mm Total length 145 mm

    11 - 14 020891/06/13

  • Dimension to model 1.1005.54(64).241 / 300 / 441 / 448 / 941 Diameter 20 mm Shaft length 122 mm Total length 180 mm Dimension to model 1.1005.54(64).701 / 760 / 761 / 762 / 773 Diameter 20 mm Shaft length 155 mm Total length 195 mm Dimension to model 1.1005.54.700 Diameter 20 mm Shaft length 155 mm

    7 Accessories / spare part (optional)

    Weather and Thermal Radiation Shield

    The use of the Weather and Thermal Radiation Shield in an appropriate combination with suitable temperature and humidity sensors reduces to a minimum the possibility of influencing the data in a negative manner by radiation, precipitation or damage.

    More exactly measuring results are achieved by using the ventilated Weather and Thermal Radiation Shield (mod. 1.1025.55.10x with ventilation). The ventilation reduces those errors which might occur during the measurements in a weather hut caused by the so-called proper climate.

    1.1025.55.00x .10x .xx0 .xx1

    w/o ventilator with ventilator 12 V DC / 2 W , incl. 5 m cable for mast tube mounting 30 - 50 mm for mast tube mounting 55 60 mm

    dimensions: 120 x 290 mm

    Remark: It is recommendable to use the weather and thermal radiation shield-compact with ventilation order-no. 1.1025.55.10x for Hygro-Thermo Transmitter model ..241 / 441 / 300 / 941 (4-20 mA)

    Membrane-filter with gauze ZE20

    The filter serves for protecting the sensor elements of the Hygro-thermo transmitter against dust in case of field application.

    1.1005.54.901

    Material: PTFE / stainless steel Dimensions: 20 x 25 mm

    Sinter filter ZE21

    The fine-pore sinter filter serves to protect the sensor elements of the Hygro-Thermo-Transmitter compact against high wind speeds (>5m/s) and dust...

    1.1005.54.902

    Material: stainless steel

    Dimensions: 20 x 25 mm

    12 - 14 020891/06/13

  • 8 EC-Declaration of Conformity

    Document-No.: 000702 Month: 10 Year: 13

    Manufacturer: A D O L F T H I E S G m b H & C o. K G Hauptstr. 76 D-37083 Gttingen

    Tel.: (0551) 79001-0 Fax: (0551) 79001-65 email: [email protected]

    Description of Product: Hygro Thermo Transmitter Compact

    Article No. 1.1005.49.960 1.1005.51.600 1.1005.54.000 1.1005.54.150 1.1005.54.160 1.1005.54.161 1.1005.54.173 1.1005.54.241 1.1005.54.300 1.1005.54.441 1.1005.54.448 1.1005.54.460 1.1005.54.461 1.1005.54.700 1.1005.54.701 1.1005.54.703 1.1005.54.741 1.1005.54.761 1.1005.54.773 1.1005.54.780 1.1005.54.781 1.1005.54.782 1.1005.54.800 1.1005.54.941 1.1005.54.961 1.1005.64.000 1.1005.64.161 1.1005.64.174 1.1005.64.701 1.1005.64.241

    specified technical data in the document: 020874/06/13; 021659/04/11; 021660/04/11; 021661/04/11 021687/01/12; 021691/01/12; 020726/08/13 The indicated products correspond to the essential requirement of the following European Directives and Regulations:

    2004/108/EC DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89/336/EEC

    2006/95/EC DIRECTIVE 2006/95/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL

    of 12 December 2006 on the harmonisation of the laws of Member States relating to electrical equipment designed for use within certain voltage limits

    552/2004/EC Regulation (EC) No 552/2004 of the European Parliament and the Council of 10 March 2004

    on the interoperability of the European Air Traffic Management network (the interoperability Regulation)

    The indicated products comply with the regulations of the directives. This is proved by the compliance with the following standards:

    Reference number Specification

    IEC 61000-6-2: 2005 Electromagnetic compatibility Immunity for industrial environment

    IEC 61000-6-3: 2006 Electromagnetic compatibility Emission standard for residential, commercial and light industrial environments

    IEC 61010-1: 2010 Safety requirements for electrical equipment for measurement, control, and laboratory use. Part 1: General requirements

    Place: Gttingen Date: 17.10.2013

    This declaration certificates the compliance with the mentioned directives, however does not include any warranty of characteristics. Please pay attention to the security advises of the provided instructions for use.

    13 - 14 020891/06/13

  • ADOLF THIES GmbH & Co. KG Hauptstrae 76 37083 Gttingen Germany P.O. Box 3536 + 3541 37025 Gttingen Phone +49 551 79001-0 Fax +49 551 79001-65 www.thiesclima.com [email protected]

    - Alterations reserved-

    14 - 14 020891/06/13

    1 Models available2 Application3 Mounting4 Maintenance5 Connection Diagrams6 Technical Data7 Accessories / spare part (optional)8 EC-Declaration of Conformity