6
8/3/2019 13144 http://slidepdf.com/reader/full/13144 1/6 IS 13144 : 1991 srr-c?fbT TT q iv * ;SFT~T 3 dhmit 4 srw w ~ +9- q ~a rF<$ 0 Indian Standard RECOMMENDATIONS FOR PROVISION OF FACILITIES OUTSIDE THE DAMS UDC 627’82 : 711’8 0 BIS 1991 BUREAU c)F INDIAN STANDARDS MANAK BHAVAN, 9 BAHADUR SHAH ZAFAR MARG NEW DELHI 110002 Augusf 1991 Price Group 1 ( Reaffirmed 1997 )

13144

Embed Size (px)

Citation preview

Page 1: 13144

8/3/2019 13144

http://slidepdf.com/reader/full/13144 1/6

IS 13144 : 1991

srr-c?fbTTT

q iv * ;SFT~T 3 dhmit 4 srww~ +9- q~a rF<$0

Indian Standard

RECOMMENDATIONS FOR PROVISION OF

FACILITIES OUTSIDE THE DAMS

UDC 627’82 : 711’8

0 BIS 1991

BUREAU c)F INDIAN STANDARDS

MANAK BHAVAN, 9 BAHADUR SHAH ZAFAR MARGNEW DELHI 110002

Augusf 1991 Price Group 1

( Reaffirmed 1997 )

Page 2: 13144

8/3/2019 13144

http://slidepdf.com/reader/full/13144 2/6

Dams ( Overflow and Non-overflow ) Sectional Committee, RVD 9

FOREWORD

This lndian Standard was adopted by the Bureau of Indian Standards after the draft finalized byDams ( Overflow and Non-overflow ) Sectional Committee had been approved by River ValleyDivision Council.

When a dam is constructed, the area around it is required to be developed by providing certainamenities and facilities. The required facilities depend upon the importance and size of dam andpotential of the lake formed,~being used as a tourist place. The facilities like lighting, watersupply and sanitary arrangements, tourist spot, gardens, transport system, medical facilities andsafety agent outside army attack are covered in this standard.

Provisions regarding lighting and facilities inside dams have been covered in IS 9297 : 1979‘Recommendations for lighting, ventilation and other facilities inside dams’. Provisions regardingdrainage system for dams have been covered in IS 9429 : 1980 ‘Code of practice for drainagesystem for earth and rockfill dams’ and IS 10135 : 1985 ‘Code of practice for drainage system forgravity dams, their foundations and abutments ( first revision ).

Provision of check-posts and watchmen’s cabins, kiosks etc, on roads leading to dam approaches,adit entrances and other vulnerable points be also made in addition to the above facilities.

Page 3: 13144

8/3/2019 13144

http://slidepdf.com/reader/full/13144 3/6

IS 13144 : 1991

Indian Standard

RECOMMENDATIONS FOR PROVISION OF

FACILITIES OUTSIDE THE DAMS

1 SCOPE

This standard covers the recommendations forprovision of facilities outside the major andmedium dams.

2 LIGHTING

2.1 Sufficient and proper lighting is a necessityoutside the dam. Lighting installations shouldprovide satisfactory illumination, for propervigilance, and monitoring of the dam andappurtenant works.

2.2 Lighting System

2.2.1 The lighting system on approach andservice roads, top of dam and surrounding areasshould generally consist of flourescent lighttubes or high pressure mercury vapour lamps.In areas where dense fog is expected, sodiumvapour lamps should be provided in operationareas. The spillway, irrigation sluice, poweroutlets, downstream face of dams, abutments etc.should be flood lit by properly located flood

lighting units. The spacing of poles for tube-lights may be about 30 m c/c.

2.2.2 Special lighting arrangements for earthdam for vigilance at night, after gorge fillingwould be necessary.

2.2.3 All wiring joints should be made in thejunction boxes provided for the purpose throughprocelain connectors. Precaution to prevententry of rain water, flood water, leakage water,etc, in the electrical installation should be taken.Additional plug points of adequate capacity may

be provided at suitable locations. The designand layout of generator, transformer, electricalcircuits, conduits and cables, switches, etc,should be properly coordinated with the layoutand design of the main components of the dam.

2.2.4 Since, in the projects areas, heavy mistis likely Taohamper visibility, a series of sodiumvapour lamps may also be installed at vulner-able points. This will additionally add to thebeauty of the area when such locations becomepopular tourist spots.

3 WATER SUPPLY AND SANITARYARRANGEMENTS

3.1 Water supply is required for drinkingpurposes, sanitary blocks, fire fighting, gardensetc. In some projects provision of water supplyto nearby-town is also made. The location anddiameter of water supply pipe should be selectedto meet individual requirement of the project.

Suitable control valves, if required outside thedam, should be properly installed for safe andconvenient operation of the system.

3.2 Raw Water Supply

Suitable pumps with stand-by capacity accordingto actual requirements should be installed forsupply and distribution of raw water for firefighting, gardens, sanitary blocks etc. Rawwater supply should also be provided near theentrance of the grouting and drainage galleriesso that necessary maintenance operation can becarried out. Arrangements should also coverother areas in the abutments where drainageholes or grouting and other protection worksare needed. The pipe line should provide forrequired valves and suitable hose connectionsspaced at required interval based on overallplanning.

3.3 Drinking Water Supply

To cater for the requirements of drinking water,suitable raw water tanks, treatment plant and

pure water sumps or elevated services reservoir,with valves and distribution system should beprovided. Drinking water facilities should bemade around the dam complex at suitablelocations including the approach road.

3.4 Sanitary Arrangements

Toilet facilities including wash basins andurinals should be provided at suitable locationsto serve project staff and tourists. At least onetoilet on each bank is recommended. Sewageand waste water should be disposed throughdrainage system and septic tanks.

4 TOURIST SPOT

4.1 Irrigation projects have aroused publicinterest resulting in increasing seasonal visitorsboth during and after construction. Large lakescreated by the project are points of interest andpotential tourist areas, Various facilities asunder may be considered and provided whererequired for tourists and visitors to the project:

a) Tourist bunglows and dormitories

b) Parking areas

c) View points

d) Information centre

e) Telephone

f) Model room

g) Fishing, Boating, Water Sports such as

skiing

1

Page 4: 13144

8/3/2019 13144

http://slidepdf.com/reader/full/13144 4/6

IS 13144 1991

h) Gardens

j) Canteen

k) Bus Stop, Post Office, Dispensary, PoliceStation, etc. ~

m) Toilets - at least one on each bank

n) Notice Board and Sign Boards.

4.2 The extent and type of facilities to beprovided for tourists will depend on potentialof the project for development as a touristcentre.

4.3 The areas under submergence may haveuneven topography, rocks, trees and areavulnerable for land sides, etc, which may en-danger the lives of tourist when boating andfishing. These areas should be properly demar-cated and unauthorized persons should not beallowed in these areas. Life boats and other

life saving arrangements may be made in thevicinity.

5 GARDEN

Well planned gardens, orchards, tree plantationand landscaping on downstream side of the damis an essential feature of irrigation projects.Suitable fountains, water courses, ete, will addto attractiveness of the garden.

6 TRANSPORT

A public transport system for the visitors shouldbe provided from the nearest township. Trans-port facilities be provided to students goingto schools or colleges from township to nearbytown.

7 MEDICAL FACILITIES

Necessary health care facilities should also beprovided which should also include the provisionof ambulance van and other requisite equipmentto meet any contingencies.

8 PROVISION OF LIGHTNINGCONDUCTORS

Lightning conductors should be provided at

suitable locations on concrete and masonrystructures.

d SAFETY AGAINST OUTSIDE ARMYATTACK

From strategic point of view dam proper, otherstructures, buildings nearby dam, light poles,etc, should be provided with camouflage coloursas these being protected structures.

Page 5: 13144

8/3/2019 13144

http://slidepdf.com/reader/full/13144 5/6

Standard Mark

The use of the Standard Mark is governed by the provisions of the Bureau o f ndian

Standards Act, 1986 and the Rules and Regulations made thereunder. The Standard Mark on

products covered by an Indian Standard conveys the assurance that they have been produced

to comply with the requirements of that standard under a well ‘defined system of inspection,

testing and quality control which is devised and supervised by BLS and operated by the pro-

ducer. Standard marked products are also continuously checked by BIS for conformity to

that standard as a further safeguard. Details of conditions under which a licence for the use

of the Standard Mark may be granted to manufacturers or producers may be obtained from

the Bureau of Indian Standards.

Page 6: 13144

8/3/2019 13144

http://slidepdf.com/reader/full/13144 6/6

Bnreao ef Indian Standards

BIS is a statutory institution established under the Bureau of htdian Standards Act , 1986 to remote

tarmonious development of the activities of standardization, marking and quality certific tion of

goods and attending to connected matters in the country.

Copyright

BIS has the copyright of all its publications. No part of these publications may be reproduced inany form without the prior permission in writing of BIS. This does not preclude the free use, in

the course of implementing the standard, of necessary details, sudh as symbols and sizes, type OF

grade designations. Enquiries relating to copyright be addressed to the Director ( Publication ), BIS.

Revision of Indian Standards

Indian Standards are reviewed periodically and revised, when necessary and amendments, if any,

are issued from time to time. Users of Indian Standards should ascertain that they are In

possession of the latest amendments or edition, Comments on this Indian Standard may be sent

to BIS giving the following reference :

Dot : No. RVD 9 ( 4289)

Amendments Issued Since Publication

Amend No. Date of Issue Text Affected

Headquarters :

BUREAU OF INDIAN STANDARDS

Manak Bhavan, 9 Bahadur Shah Zafar Marg, New Delhi 110002

Telephones : 331 01 31, 331 13 75

Regional Offices :

Central : Manak Bhavan, 9 Bahadur Shah Zafar MargNEW DELHI 110002

Eastern : l/14 C.I.T. Scheme VII M, V.I.P. Road, Maniktola

CALCUTTA 700054

Northern : SC0 445-446, Sector 35-C, CHANDIGARH 160036

Southern : C.I.T. Campus, IV Cross Road, MADRAS 600113

Western : Manakalaya, E9 MIDC, Marol, Andheri ( East )

BOMBAY 400093

Telegrams : Manaksanstha

( Common to all Offices )

Telephone

331 01 31331 13 75

37 86 62

53 38 43

2350216

6 32 92 99

Branches : AHMADABAD. BANGALORE. BHOPAL. BHUBANESHWAR.

COIMBATORE. FARIDABAD. GHAZIABAD. GUWAHATI.

HYDERABAD. JAIPUR. KANPUR. PATNA. THIRUVANANTHAPURAM.

Printed at Swatantra Bharat Press, Delhi. India