  • BTS3900 Configuration Level: internal

    2009-7-2 Page1, Total17

    BTS3900 Configuration Guideline

    Drafted by Quan Kuifa Date JUN.10.2009

    Reviewed by Date

    Approved by Date

    Huawei Technologies Co., Ltd.

    All rights reserved.

  • BTS3900 Configuration Level: internal

    2009-7-2 Page2, Total17

    This guide instructs that how to configur BTS3900 in the BSC6000.also that how to implement BTS swap.All the operations is based on the LMT and MML. The content of this guide is as below: 1, Main process of BTS configuration 2, Alarm configuration for BTS 3, Data configuration for BTS swap

  • BTS3900 Configuration Level: internal

    2009-7-2 Page3, Total17

    1. Main process of BTS configuration Keep the same configuartion with site Batna CCLT 05503 in the Batna. Step1: add site

    Step2: add cell

  • BTS3900 Configuration Level: internal

    2009-7-2 Page4, Total17

    Step3: set attributes

  • BTS3900 Configuration Level: internal

    2009-7-2 Page5, Total17

    Step4: add FMU and GATM board (Each BTS3900 is configured with 6 DRFU.1 FMU.1 GATM.1 BBU.) Add FMU in slot 8 and GATM in slot 17, because the monitor signal cable of FMU and GATM are connected to MON0 and MON1 of UPEU separately.which keeps the confiuration same with the practical installation.

  • BTS3900 Configuration Level: internal

    2009-7-2 Page6, Total17

    Step5: add RXU Chain

  • BTS3900 Configuration Level: internal

    2009-7-2 Page7, Total17

    Use the RF cable connection tool to generate the connection. For the site 05503(S4/4/4) is as below:

  • BTS3900 Configuration Level: internal

    2009-7-2 Page8, Total17

    Step6: add RXU (RFU) Principia for RXUs name: PortX_SlotX_PosX. PortX: Port No. X of GTMU SlotX: Slot No. X of DRFU PosX: Position No.X of the DRFU in the chain.

    Keep confiuration same with the practical connection.Finally the RXU chain topo is as below.

  • BTS3900 Configuration Level: internal

    2009-7-2 Page9, Total17

    Step7: bind logical TRX From Trx No.0 to Trx No.11

    Step8: Set TRX attributes (Send Receive Mode)

  • BTS3900 Configuration Level: internal

    2009-7-2 Page10, Total17

    Set the Send Receive Mode due to pratical situation. Because just one ANT port of DRFU is used, the Single Antenna Double Receiver is chosen.

    Step9: Set cell attributes Almost the configuration process is same with BSC32. One parameter should be cared, which isPower Type. 20W is chosen due to the Send Receive Mode.

  • BTS3900 Configuration Level: internal

    2009-7-2 Page11, Total17

    2. Alarm configuration for BTS3900 The BBU can support 2 RS485 bus and 16 line of on-off alarm maximally. There are just 1 UPEU configured in BTS3900 in the packeting list. The No. of on-off alarm for UPEU is as below.

    The monitor signal of DCDU-01 is connected to No.8 alarm of EXT-ALM0 of UPEU. Step1: set site attributes

    Step2: set Alarm Shield Flag 2 (Hex) The 8 bits (from low to high) of alarm sheild flag 2 determines the No.8-15 on-off alarm. 0 means shield, 1 means non-shield. The alarm sheild flag 2 is set as 01 to enable the DCDU-01 arlarm.

  • BTS3900 Configuration Level: internal

    2009-7-2 Page12, Total17

    Step3: set Alarm Voltage Definition

  • BTS3900 Configuration Level: internal

    2009-7-2 Page13, Total17

    Step4: set external alarm port Set the external alarm port for the on-off alarm of the UPEU as below.

    Step5: name the external alarm Click the Alarm Matintenance in the LMT mean

    Find the No.5048 alarm.then right-click it.choose as below.

  • BTS3900 Configuration Level: internal

    2009-7-2 Page14, Total17

    Set the Alarm name.

  • BTS3900 Configuration Level: internal

    2009-7-2 Page15, Total17

    3. Data configuration for BTS swap Step1: configure the site with LMT in offline mode Note: Configure the site on the same slot and port as the site to be swapped.

    Step2: export the site data in offline mode

    It will take about 5 minutes to export one site data. Step3: backup the data of the swapped site in online mode Note: do this after blocking the site.

  • BTS3900 Configuration Level: internal

    2009-7-2 Page16, Total17

    The exported result is the format of text as above, which will be used to edit the adjacent cell for BTS3900 later. Step4: delete the swapped site in online mode

    Step5: import the data in online mode

  • BTS3900 Configuration Level: internal

    2009-7-2 Page17, Total17

    The log above indicates that importing is successful. Step6: edit the MML script Use the UltraEdit tool to edit the exported file namedBTS3900 adjacent cell above. CommanADD CELL2GNC will be used to add adjacent cell. Its very to edit the MML script with the UltraEdit tool in column mode. Take care theBidirectional Adjacent CellandSingle directional Adjacent Cell! For the theBidirectional Adjacent Cell, command ADD CELL2GNC should be executed twice to add adjacent cell in both cell. Step7: execute the MML script in batch Log in the MML and execute the scriptBTS3900 adjacent cell in batch.

    /ColorImageDict > /JPEG2000ColorACSImageDict > /JPEG2000ColorImageDict > /AntiAliasGrayImages false /CropGrayImages true /GrayImageMinResolution 300 /GrayImageMinResolutionPolicy /OK /DownsampleGrayImages true /GrayImageDownsampleType /Bicubic /GrayImageResolution 300 /GrayImageDepth -1 /GrayImageMinDownsampleDepth 2 /GrayImageDownsampleThreshold 1.50000 /EncodeGrayImages true /GrayImageFilter /DCTEncode /AutoFilterGrayImages true /GrayImageAutoFilterStrategy /JPEG /GrayACSImageDict > /GrayImageDict > /JPEG2000GrayACSImageDict > /JPEG2000GrayImageDict > /AntiAliasMonoImages false /CropMonoImages true /MonoImageMinResolution 1200 /MonoImageMinResolutionPolicy /OK /DownsampleMonoImages true /MonoImageDownsampleType /Bicubic /MonoImageResolution 1200 /MonoImageDepth -1 /MonoImageDownsampleThreshold 1.50000 /EncodeMonoImages true /MonoImageFilter /CCITTFaxEncode /MonoImageDict > /AllowPSXObjects false /CheckCompliance [ /None ] /PDFX1aCheck false /PDFX3Check false /PDFXCompliantPDFOnly false /PDFXNoTrimBoxError true /PDFXTrimBoxToMediaBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXSetBleedBoxToMediaBox true /PDFXBleedBoxToTrimBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXOutputIntentProfile () /PDFXOutputConditionIdentifier () /PDFXOutputCondition () /PDFXRegistryName () /PDFXTrapped /False

    /Description > /Namespace [ (Adobe) (Common) (1.0) ] /OtherNamespaces [ > /FormElements false /GenerateStructure true /IncludeBookmarks false /IncludeHyperlinks false /IncludeInteractive false /IncludeLayers false /IncludeProfiles true /MultimediaHandling /UseObjectSettings /Namespace [ (Adobe) (CreativeSuite) (2.0) ] /PDFXOutputIntentProfileSelector /NA /PreserveEditing true /UntaggedCMYKHandling /LeaveUntagged /UntaggedRGBHandling /LeaveUntagged /UseDocumentBleed false >> ]>> setdistillerparams> setpagedevice

    BTS3900 Configuration

    Level: internal

    BTS3900 Configuration Guideline

    Drafted by

    Quan Kuifa

    Date

    JUN.10.2009

    Reviewed by

    Date

    Approved by

    Date

    Huawei Technologies Co., Ltd.

    All rights reserved.

    This guide instructs that how to configur BTS3900 in the BSC6000.also that how to implement BTS swap.All the operations is based on the LMT and MML.

    The content of this guide is as below:

    1, Main process of BTS configuration

    2, Alarm configuration for BTS

    3, Data configuration for BTS swap

    1. Main process of BTS configuration

    Keep the same configuartion with site Batna CCLT 05503 in the Batna.

    Step1: add site

    Step2: add cell

    Step3: set attributes

    Step4: add FMU and GATM board

    (Each BTS3900 is configured with 6 DRFU.1 FMU.1 GATM.1 BBU.)

    Add FMU in slot 8 and GATM in slot 17, because the monitor signal cable of FMU and GATM are connected to MON0 and MON1 of UPEU separately.which keeps the confiuration same with the practical installation.

    Step5: add RXU Chain

    Use the RF cable connection tool to generate the connection. For the site 05503(S4/4/4) is as below:

    Step6: add RXU (RFU)

    Principia for RXUs name: PortX_SlotX_PosX.

    PortX: Port No. X of GTMU

    SlotX: Slot No. X of DRFU

    PosX: Position No.X of the DRFU in the chain.

    Keep confiuration same with the practical connection.Finally the RXU chain topo is as below.

    Step7: bind logical TRX

    From Trx No.0 to Trx No.11

    Step8: Set TRX attributes (Send Receive Mode)

    Set the Send Receive Mode due to pratical situation. Because just one ANT port of DRFU is used, the Single Antenna Double Receiver is chosen.

    Step9: Set cell attributes

    Almost the configuration process is same with BSC32.

    One parameter should be cared, which isPower Type. 20W is chosen due to the Send Receive Mode.

    2. Alarm configuration for BTS3900

    The BBU can support 2 RS485 bus and 16 line of on-off alarm maximally.

    There are just 1 UPEU configured in BTS3900 in the packeting list.

    The No. of on-off alarm for UPEU is as below.

    The monitor signal of DCDU-01 is connected to No.8 alarm of EXT-ALM0 of UPEU.

    Step1: set site attributes

    Step2: set Alarm Shield Flag 2 (Hex)

    The 8 bits (from low to high) of alarm sheild flag 2 determines the No.8-15 on-off alarm. 0 means shield, 1 means non-shield.

    The alarm sheild flag 2 is set as 01 to enable the DCDU-01 arlarm.

    Step3: set Alarm Voltage Definition

    Step4: set external alarm port

    Set the external alarm port for the on-off alarm of the UPEU as below.

    Step5: name the external alarm

    Click the Alarm Matintenance in the LMT mean

    Find the No.5048 alarm.then right-click it.choose as below.

    Set the Alarm name.

    3. Data configuration for BTS swap

    Step1: configure the site with LMT in offline mode

    Note: Configure the site on the same slot and port as the site to be swapped.

    Step2: export the site data in offline mode

    It will take about 5 minutes to export one site data.

    Step3: backup the data of the swapped site in online mode

    Note: do this after blocking the site.

    The exported result is the format of text as above, which will be used to edit the adjacent cell for BTS3900 later.

    Step4: delete the swapped site in online mode

    Step5: import the data in online mode

    The log above indicates that importing is successful.

    Step6: edit the MML script

    Use the UltraEdit tool to edit the exported file namedBTS3900 adjacent cell above.

    CommanADD CELL2GNC will be used to add adjacent cell. Its very to edit the MML script with the UltraEdit tool in column mode.

    Take care theBidirectional Adjacent CellandSingle directional Adjacent Cell! For the theBidirectional Adjacent Cell, command ADD CELL2GNC should be executed twice to add adjacent cell in both cell.

    Step7: execute the MML script in batch

    Log in the MML and execute the scriptBTS3900 adjacent cell in batch.

    2009-7-2

    Page1, Total17