8/13/2019 5035dc Volt Amp Meter
1/3
WARNING:
It is important to read the Setup Guide before installing or commissioning this instrumentas it contains important information relating to safety and EMC.
Operation Manual
SAFETY CONSIDERATIONS
This instrument has no power-on switch; it will be in operation as soon as power is connected.
Do not exceed voltage rating stated on the specifications.
Always disconnect power before changing signal and power connections.
Do not use this instrument on a work bench without its case for safety reasons.
Do not operate this instrument in flammable or explosive atmospheres.
Do not expose this instrument to rain or moisture.Whenever EMC is an issue, always use shielded cables.
Copyright 2009 SUPERwwwSTORE DigitalWorld. All rights reserved. This document may not be copied,
photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form,in whole or in part, without prior written consent of SUPERwwwSTORE DigitalWorld.
The information contained in this document is believed to be correct but SUPERwwwSTORE DigitalWorld
accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
Thank you for purchasing our product
-- 1 --
Unpacking and Inspection
At the end of its life cycle, dispose of this product in accordance with local and national disposal regulations.
Instrument which will not be installed immediately should be stored in a clean, dry location.
Careful use of the instrument will provide years of reliable service.
The use of this instrument in a manner other than specified may impair theprotection of the instrument and subject the user to hazard.
Do not make signal wiring changes or connections when power is applied to the instrument.Make signal connections before power is applied and, if reconnection is required, disconnectthe power before such wiring is attempted. Do not connect more than one meter to the same
Please verify the panel cutout dimensions and mount according to instructions.
power supply if the meters cannot use the same signal ground.
the instrument and inspect for obvious shipping damage. Please do not attempt toYour instrument has been carefully tested and inspected prior to shipment. Unpack
install or operate the unit if damage is found.
This instrument is a panel mount device protected in accordance with Class I of EN61010. Installation of this instrument should be done by Qualified personnel. In orderto ensure safe operation, the following instructions should be followed.
DIGITAL PANEL METER
YOUR BEST ONLINE STORE
SUP RST RT RSUP Rwww
Please consult your licensed electrician/electrical engineer for professional advice before installation.
2-Year Limited Warranty SUPERwwwSTORE warrants your newly purchased product against defects in
Warranty Registration is not necessary to obtain the applicable warranty on the product. The date of purchase willmaterial and workmanship existing at the time of manufacture for a period of two years from the date of purchase.
be used to determine the warranty period when warranty service is requested.
8/13/2019 5035dc Volt Amp Meter
2/3
4-Pin connection cable (300 mm) included
-- 2 --
RANGES AND ELECTRICAL SPECIFICATION:
DC VOLTAGE MODELS
Measuring Range
Accuracy
Resolution
Input Impedance Sample Rate Max. Input Signal
0 ~ 1999 mV 1 mV 1 M ohm
0 ~ 1.999 V
0 ~ 19.99 V 1 M ohm
1 M ohm2.5 Reading/sec.
0.2%
KEY FEATURES:
-
12.7 mm (0.5 inches) digit height
-
-Polarity : Automatic, "-" displayed
-Input signal and power supply can have common ground
-Easy to install (DIY), snap-in/mount in panel
OPERATION SPECIFICATION:
Power Source ..5V to 24V DC poweredPower Consumption
Operating Temperature
Storage Temperature
Maximum Count........................
1999 (3-1/2 digits)
Over Range Indication.."1" or "-1" shown in the display
-Automatic zero reading for 0V input
-Ideal for auto, boat, industrial & domestic uses
-Dual-Slope integration A/D converter system
-
Ultra-bright 7-Segment Backlight LCD display
-
8/13/2019 5035dc Volt Amp Meter
3/3-- 3 --
- Digital Panel Meter Installation and Wiring Diagram
DIMENSIONS All dimensions in mm (inches)
W I R I N G I N F O R M A T I O N
To be connected in
CAUTION:
Calibration
79 (3.1)
20
(0.
8)
45 (1.8)
71 (2.8)PANEL CUTOUT SIZE
Potentiometer
Damage to the unit may occur if the power source/signal polarity is reversed OR power source >24Vdc is apllied.
Power SourcePower Source
Volts/Amps to be measured
REAR VIEW
39
(1.
5)
43
(1.
7)
a=2
(0.0
8)
a b
CONNECTOR WIRING
SIDE
VIEW
b=2
3(0.9
)
Volts/Amps to be measured
+_
+
_+v I N
AMMETER
SUPERwwwSTORE
To be connected in
To be used with Ammeter (10A or over) & must be in LOW side (nearest toSHUNTAny device such as a lamp, horn, wiper motor,alarm,...that consumes electricity. And LoadLOAD
VOLTMETER
PARALLEL in the circuitSERIES in the circuit
+_
+_
vvININ
+
_
LOAD
6~24V DC
+_
vvININ
6~24V
DC
+
_LOAD
Powered by a separate supply source
must be used &
-NEGATIVE terminal)
activated when measuring amps/current.
+-- I N
v
+
+
-
-
A) VOLTMETERPowered by the same source (6~24Vdc)
+_
+__
_
_
_
_
_
__
_
__ _
_
(6V~24V DC)
v
IN
+_
+_
vvININ
vvININ
Powered by a separate supply sourceB) AMP METER / AMMETER
Powered by the same source (6~24Vdc)
+_
+_
_
_
__
___ 6~24 V DC
LOAD
+_
SHUNT
SignalInput
__
_
_
_
_
_
_+
+
-
-
v
IN
+
+
-
-
v
IN
+
+
-
-
v
IN
Voltmeter Voltmeter
Ammeter Ammeter
Powered by separate supply sourcesC) VOLTMETER + AMMETER
Powered by the same source (6~24Vdc)
+_
+_
vvININ
6~24V DC
+_
vvININ
+
+
-
-+_
+_
_
_
___
_
__
v
IN +
+
-
-
v
IN
Voltmeter Voltmeter
+_
+
_vvIN
IN
vvININ
+_
+
__
_
__
___ 6~24 V DC
LOAD
+_
SHUNT
SignalInput
__
_
_
____
+
+
-
-
v
IN +
+
-
-
v
IN
Ammeter Ammeter
_
_
__
___6~24V DC
+_
LOAD
+_
SHUNT
SignalInput
__
_
_
_
_
__
___6~24V DC
+_
LOAD+
_
SHUNT
SignalInput
__
_
_
_
_
___
_
__ __
SignalInput
Signal
Inputv v
v v
A A
A A
Please consult your licensed electrician/electrical engineer for professional advice before installation.