6 - Comando Console

Embed Size (px)

Citation preview

*** RODANDO PPDELTA:

$ ppdelta 300 all spoippp01 fruni/130801 lmi

$ ppdelta 300 all spoippp01 fruni/130801 framer

$ ppdelta 300 all spoippp01 fruni/130801 dlci/***

D ******* (SGO) COMANDOS PARA TESTE PELO TELNET ( SGO ) ******

TELNET 172.201.192.22LOGIN:SPPACPASWORD:SPPACEX: TELNET SPOPDPP03 ENTER LOGIN: E011172SENHA:MDM

1 - COMANDOS PARA VERIFICAR QUAL O FRUNI OU FRATM: D-P LP/**** E1/**** CH/**** - COMANDO LISTA SE E FRUNI OU FRATM

2 - COMANDOS PARA VERIFICAR ROTEADOR :

D FRUNI/ ***** LMI - COMANDO PARA VERIFICAR SE O ROUTER ESTA EM :UP++++ OU DOWN XXXXD-P FRUNI/ ***** LMI - COMANDO PARA VERIFICAR CONFIGURAAO EXEMPLO:Na linha PROCEDURES = "ANSI" ou "autoConfigure", indica a configurao do clock da rede pacotes com o lado externo (ponta remota).Quando estsetado para "autoConfigure" a rede pacotes se autoconfigura com o clock da ponta remota, Caso esteja em "ANSI" o clock eh configurado de acordo com o clock da ponta remota (lado externo)

3 - COMANDOS PARA VERIFICAR DLCI / VERIFICAR CIR E EIR:

D FRUNI/ **** DLCI/* ( O * E PARA LISTAR O DLCI) QUANDO IDENTIFICADO O DLCI INFORMAR O MESMO PARA VERIFICAR O CIR E EIREX: D FRUNI/**** DLCI/16 - IRA LISTAR CONFIGURAOES DO DLCI

4 - COMANDOS PARA VERIFICAR O TRAFEGO TELNET/CONSOLE:

D FRUNI/**** FRAMER - IRA MOSTRAR O TRAFEGO DO CIRCUITO----------------------------------------------------------

5 - COMANDOS PARA VERIFICAR SE AS PORTA/SLOT/TIME SLOT ESTAO INSTALADOS:EX: L LP/**** - IRA LISTAR AS PORTAS L LP/1 E1/**** - IRA LISTAR OS SLOTS L LP/1 E1/3 CH/**** - IRA LISTAR OS TIMESLOTS D-P LP/1 E1/3 CH/**** - IRA LISTAR A ESTRUTURA

6 - COMANDOS PARA FECHAR LOOP PELA TELNET/CONSOLE: para testes com tecnico GTD na tx ou no cliente local, usando o test set para emular frame

LOCK LP/**** E1/**** CH/**** SET LP/**** E1/**** CH/**** TEST TYPE EXTERNALLOOP,DURA 60 (quando fruni)

SE O COMANDO DE CIMA DER ERRO SETAR ESSE:SET LP/**** E1/**** CH/**** TEST TYPE PAYLOADLOOP,DURA 60 (quando fratm)

START LP/**** E1/**** CH/**** TESTSTOP TESTUNLOCK LP/**** E1/**** CH/****

7 - COMANDOS PARA ENXERGAR LOOP PELA TELNET/CONSOLE:(quando cpcc 72, fechar loop na det ou se no cliente possuir modem gerenciavel acionar LDR/LDL)

LOCK LP/**** E1/**** CH/**** bloqueando a LP dentro do E1SET LP/**** E1/**** CH/**** TEST TYPE MANU,DURA 60 ==> setando a porta, para o teste manual de 60 minutosSTART LP/**** E1/**** CH/**** TEST ===> inicia o testeD LP/**** E1/**** CH/**** TEST ==> visualiza a carga do teste ( ou seja visualiza o loop fechado na r.deterministica) STOP TEST LP/ E1/ CH/ TEST ==> pra o testeUNLOCK LP/**** E1/**** CH/**** ==> desbloqueia a porta

8- D-P FRATM OU FRUNI/ DNA DNA OU ADDR/// COMANDO PARA VERIFICAR DNA CLIENTE

9-ping-rt fruni/ ***** dlci/***** vc

COMANDOS PARA ENTRAR DENTRO DO CONSOLE NORTEL MDM PARA MANOBRA DE PP:

SunOS 5.8

login: sppacPassword: sppac

Last login: Mon Nov 6 11:14:59 from 10.11.4.195Sun Microsystems Inc. SunOS 5.8 Generic Patch October 2001You have new mail.

CGER > cd /opt/M*NMS/bin

CGER > setenv DISPLAY 10.11.4.195:0.0 ( obs:sempre colocar o ip da maquina que voce esta utilizando ,INICIAR ,EXECULTAR ,DIGITAR :CMD ipconfig VERIF IP )

CGER > nmstool &

[1] 270CGER >

CONFIGURAO FRATM

(CONFIGURAO EXISTENTE NA REDE)

- (OCOOSPP03 FRATM/30103 DL/16) => (SPOPIPP03 ATMIF/131 VCC/0.56)

***COMANDO PARA SABER ENDEREO DO ATMIF PARA ONDE O CIRCUITO DE ACESSO IR APONTAR( USADO O "PRIMARY"):

#1675: * SPOPIPP02 L ATMIF/131 UNI ADDR/*AtmIf/131 Uni Addr/39076F0015010109020000000013010000000000,primaryAtmIf/131 Uni Addr/39076F001501010902000000000020480D008300,defaultok 2006-08-11 16:37:10.51

------------------------COMANDOS PARA CONFIGURAR:-----------------------

#ENTRAR NO MODULOOCOOSPP03 ST P

#ADICIONAR FRATMOCOOSPP03 ADD FRATM/30103

#CONFIGURAR LMIOCOOSPP03 SET FRATM/30103 LMI PROCEDURES AUTOCONFIGURE

#ADICIONAR POSIO NA E1OCOOSPP03 ADD LP/3 E1/1 CH/3

#CONFIGURAR O CN 3 PARA O TS 3 (IMPORTANTE RELACIONAR O CANAL AO TIME SLOT)OCOOSPP03 SET LP/3 E1/1 CH/3 TS 3

#ATRIBUIR A POSIO AO SERVIOOCOOSPP03 SET FRATM/30103 FRAMER INTERFACENAME LP/3 E1/1 Channel/3

#ADICIONAR O DLCIOCOOSPP03 ADD FRATM/30103 DLCI/16

#CONFIGURAR O DLCI E O EIROCOOSPP03 SET FRATM/30103 DLCI/16 SP CIR 64000,BC 64000,BE 0

#ADICIONAR SERVIO SIWFOCOOSPP03 ADD FRATM/30103 DLCI/16 SIWF

#ADICIONAR SERVIO SPVCOCOOSPP03 ADD FRATM/30103 DLCI/16 SIWF SPVC

#APONTAR O DLCI PARA O VCC DO ATMIFOCOOSPP03 SET FRATM/30103 DLCI/16 SIWF SPVC RDDR 39076F0015010109020000000013010000000000,RCI 0.56

#ADICIONAR O SERVIO DE ENDEREO OCOOSPP03 ADD FRATM/30103 ADDR

#CONFIGURAR O ENDEREO (O "x" DEVE SER MINSCULO)OCOOSPP03 SET FRATM/30103 ADDR ADDR x.72511408030103

CONFIGURAR E APONTAR UM FRUNI

------------------------------------------------------------------------------#ENTRAR NO MODULOOCOOSPP03 ST P

#ADICIONAR FRUNIOCOOSPP03 ADD FRUNI/30103

#CONFIGURAR LMIOCOOSPP03 SET FRUNI/30103 LMI PROCEDURES AUTOCONFIGURE

#ADICIONAR POSIO NA E1OCOOSPP03 ADD LP/3 E1/1 CH/3

#CONFIGURAR O Ch 3 PARA O TS 3 (IMPORTANTE RELACIONAR O CANAL AO TIME SLOT)OCOOSPP03 SET LP/3 E1/1 CH/3 TS 3

#ATRIBUIR A POSIO AO SERVIOOCOOSPP03 SET FRUNI/30103 FRAMER INTERFACENAME LP/3 E1/1 Channel/3

#ADICIONAR O DLCIOCOOSPP03 ADD FRUNI/30103 DLCI/16

#CONFIGURAR O EIROCOOSPP03 SET FRUNI/30103 DLCI/16 SP CIR 64000,BC 64000,BE 0

#APONTAR A POSIO PARA COMUNICAR COM OUTRA PONTAOCOOSPP03 SET FRUNI/30103 DLCI/16 DC 72511630040120,DLCI 114

// /