6-Port AntennaFrequency RangeDual PolarizationHPBWAdjust. Electr. DTset by
1710–2690 1710–2690 1710–2690
X X X
65° 65° 65°
2°–14° 2°–14° 2°–14°
80010727 Page 1 of 4
Y1Y1 Y2Y2 Y3Y393
6.46
15/d
ng
mn
04.1
8.05
.06
Sub
ject
to
alte
ratio
n.
6-Port Antenna 1710–2690/1710–2690/1710–2690 65°/65°/65° 18/18/18dBi 2°–14°/2°–14°/2°–14°T
Type No. 80010727Left system Y1, connector 1–2Y1, connector 1–2
1710–2690Frequency Range MHz 1710 – 1880 1850 – 1990 1920 – 2180 2300 – 2400 2490 – 2690Gain at mid Tilt dBi 17.6 18.2 18.3 18.5 18.5Gain over all Tilts dBi 17.5 ± 0.5 18.2 ± 0.3 18.2 ± 0.2 18.4 ± 0.4 18.2 ± 0.5Horizontal Pattern:Azimuth Beamwidth ° 67 ± 4.3 64 ± 2.3 62 ± 2.3 59 ± 2.9 57 ± 3.3Front-to-Back Ratio,Total Power, ± 30° dB > 25 > 24 > 24 > 24 > 24
Cross Polar Discriminationat Boresight dB > 25 > 25 > 25 > 27 > 20
Cross Polar Discriminationover Sector dB > 12.0 > 10.0 > 9.0 > 8.5 > 10.0
Azimuth Beam Port-to-Port Tracking dB < 1.0 < 1.0 < 1.0 < 1.5 < 2.0
Vertical Pattern:Elevation Beamwidth ° 7.0 ± 0.5 6.4 ± 0.3 6.1 ± 0.5 5.3 ± 0.2 4.8 ± 0.3Electrical Downtiltcontinuously adjustable ° 2.0 – 14.0
Tilt Accuracy ° < 0.4 < 0.4 < 0.4 < 0.4 < 0.3First Upper Side Lobe Suppression dB > 17 > 20 > 20 > 18 > 19
Cross Polar Isolation dB > 30Port to Port Isolation dB > 30 (Y1 // Y2 // Y3)Max. Effective Powerper Port W 250 (at 50 °C ambient temperature)
Max. Effective PowerPort 1–2 W 500 (at 50 °C ambient temperature)
Values based on NGMN-P-BASTA (version 9.6) requirements.
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected]
All specifications are subject to change without notice.The latest specifications are available at www.kathreinusa.com
6-Port Antenna
Page 2 of 4 80010727
936.
4615
/d
ngm
n 04
.18.
05.0
6 S
ubje
ct t
o al
tera
tion.
Center system Y2, connector 3–4Y2, connector 3–4
1710–2690Frequency Range MHz 1710 – 1880 1850 – 1990 1920 – 2180 2300 – 2400 2490 – 2690Gain at mid Tilt dBi 17.3 17.8 18.0 18.1 18.0Gain over all Tilts dBi 17.2 ± 0.4 17.8 ± 0.4 17.9 ± 0.3 17.8 ± 0.5 17.9 ± 0.5Horizontal Pattern:Azimuth Beamwidth ° 68 ± 7.0 62 ± 4.9 61 ± 3.4 63 ± 2.5 59 ± 3.9Front-to-Back Ratio,Total Power, ± 30° dB > 24 > 24 > 24 > 25 > 24
Cross Polar Discriminationat Boresight dB > 26 > 28 > 30 > 29 > 24
Cross Polar Discriminationover Sector dB > 10.5 > 9.5 > 10.5 > 9.0 > 8.5
Azimuth Beam Port-to-Port Tracking dB < 1.5 < 1.0 < 1.5 < 2.0 < 2.5
Vertical Pattern:Elevation Beamwidth ° 6.9 ± 0.4 6.4 ± 0.3 6.1 ± 0.4 5.3 ± 0.2 5.0 ± 0.3Electrical Downtiltcontinuously adjustable ° 2.0 – 14.0
Tilt Accuracy ° < 0.4 < 0.3 < 0.3 < 0.4 < 0.2First Upper Side Lobe Suppression dB > 20 > 24 > 22 > 22 > 18
Cross Polar Isolation dB > 28Port to Port Isolation dB > 30 (Y1 // Y2 // Y3)Max. Effective Powerper Port W 250 (at 50 °C ambient temperature)
Max. Effective PowerPort 3–4 W 500 (at 50 °C ambient temperature)
Values based on NGMN-P-BASTA (version 9.6) requirements.
Right system Y3, connector 5–6Y3, connector 5–6
1710–2690Frequency Range MHz 1710 – 1880 1850 – 1990 1920 – 2180 2300 – 2400 2490 – 2690Gain at mid Tilt dBi 17.6 18.2 18.3 18.5 18.6Gain over all Tilts dBi 17.6 ± 0.5 18.1 ± 0.3 18.2 ± 0.3 18.4 ± 0.5 18.3 ± 0.4Horizontal Pattern:Azimuth Beamwidth ° 68 ± 3.9 65 ± 2.3 64 ± 2.8 58 ± 4.2 57 ± 2.4Front-to-Back Ratio,Total Power, ± 30° dB > 24 > 25 > 24 > 23 > 22
Cross Polar Discriminationat Boresight dB > 24 > 24 > 25 > 25 > 21
Cross Polar Discriminationover Sector dB > 13.0 > 10.5 > 9.5 > 8.0 > 11.5
Azimuth Beam Port-to-Port Tracking dB < 1.0 < 1.0 < 1.0 < 2.0 < 2.0
Vertical Pattern:Elevation Beamwidth ° 6.9 ± 0.5 6.4 ± 0.3 6.1 ± 0.4 5.3 ± 0.2 4.8 ± 0.2Electrical Downtiltcontinuously adjustable ° 2.0 – 14.0
Tilt Accuracy ° < 0.3 < 0.4 < 0.4 < 0.4 < 0.5First Upper Side Lobe Suppression dB > 19 > 23 > 23 > 21 > 21
Cross Polar Isolation dB > 30Port to Port Isolation dB > 30 (Y1 // Y2 // Y3)Max. Effective Powerper Port W 250 (at 50 °C ambient temperature)
Max. Effective PowerPort 5–6 W 500 (at 50 °C ambient temperature)
Values based on NGMN-P-BASTA (version 9.6) requirements.
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected]
All specifications are subject to change without notice.The latest specifications are available at www.kathreinusa.com
6-Port Antenna
For downtilt mounting use the clamps for an appropriate mast diameter together with the downtilt kit.
Material: Refl ector screen: Aluminum.Fiberglass radome: The grey fi berglass radomes of these antennas are very stable and extraordinarily stiff. They are resistant to ultraviolet radiation and can also be painted to match their surroundings.All screws and nuts: Stainless steel.
Grounding: The metal parts of the antenna including the mounting kit and the inner conductors are DC grounded.
80010727 Page 3 of 4
936.
4615
/d
ngm
n 04
.18.
05.0
6 S
ubje
ct t
o al
tera
tion.
1496
| 58
.9
1607
| 63
.3
1)2)
1475
| 58
.1
1) 64 | 2.52) 9 | 0.4
All dimensions in mm | inches
Electrical specifi cations, all systems
Impedance Ω 50VSWR < 1.5Return Loss dB > 14Interband Isolation dB > 30Passive Intermodulation dBc < –150 (2 x 43 dBm carrier)Polarization ° +45, –45Max. Effective Powerfor the Antenna W 800 (at 50 °C ambient
temperature)Values based on NGMN-P-BASTA (version 9.6) requirements.
Mechanical specifi cations
Input 6 x 7-16 female
Connector Position bottom
Adjustment Mechanism FlexRET,continuously adjustable
Wind load(at Rated Wind Speed: 150 km/h)
N | lbf Frontal 860 | 193Lateral 200 | 45Rearside 860 | 193
Max. Wind Velocity km/hmph
200124
Height / Width / Depth mminches
1475 / 378 / 10358.1 / 14.9 / 4.1
Category of Mounting Hardware M (Medium)
Weight kglb
18.0 / 20.2 (clamps incl.)39.7 / 44.5 (clamps incl.)
Packing Size mminches
2000 / 549 / 12078.7 / 21.6 / 4.7
Scope of Supply Panel, FlexRET and 2 units of clamps for 42–115 mm |
1.7–4.5 inches diameter
Accessories (order separately if required)
Type No. Description Remarksmm | inches
Weightapprox. kg | lb
Units per antenna
731651 1 clamp Mast diameter: 28 – 60 | 1.1 - 2.4 0.8 | 1.8 285010002 1 clamp Mast diameter: 110 – 220 | 4.3 – 8.7 2.7 | 6.0 285010003 1 clamp Mast diameter: 210 – 380 | 8.3 – 15.0 4.8 | 10.6 2737978 1 downtilt kit Downtilt angle: 0° – 15° 2.3 | 5.1 186010154 Site Sharing Adapter 3-way (see fi gure below) 0.65 | 1.486010155 Site Sharing Adapter 6-way (see fi gure below) 1.35 | 3.0
Accessories (included in the scope of supply)738546 1 clamp Mast diameter: 42 – 115 | 1.7 – 4.5 1.1 | 2.4 286010153 FlexRET
Site Sharing Adapter3-way
FlexRET
BTS-A BTS-B BTS-C
FlexRET FlexRET
AISG
Site Sharing Adapter6-way
FlexRET
BTS3 BTS4
FlexRET FlexRET
BTS2BTS1 BTS5 BTS6
AISG
Configuration example with Site Sharing Adapter 86010154
Configuration example with Site Sharing Adapter 86010155
For more information please refer to the respective data sheets.
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected]
All specifications are subject to change without notice.The latest specifications are available at www.kathreinusa.com
Any previous data sheet issues have now become invalid.
6-Port Antenna
936.
4615
/d
ngm
n 04
.18.
05.0
6 S
ubje
ct t
o al
tera
tion.
Y1(L) / Y2(C) / Y3(R) 1710–2690
120 | 4.7
220 | 8.7
320 | 12.6
378 | 14.9
Bottom view
All dimension in mm | inches
103
| 4.1
Layout of interface:
Correlation Table
Frequency range Array Connector
1710–2690 MHz Y1 1–21710–2690 MHz Y2 3–41710–2690 MHz Y3 5–6
Y1 Y2 Y3Left RightCenter
Page 4 of 4 80010727
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected]
All specifications are subject to change without notice.The latest specifications are available at www.kathreinusa.com
738546 Page 1 of 1
Mounting HardwareClamp Included in the Scope of Supply
936.
3920
/c
Sub
ject
to a
ltera
tion.
Suitable for mast diameter (mm)[inches]
42 – 115[1.65 – 4.53]
Antenna – mast distance (mm)[inches]
20 – 25[0.79 – 0.98]
Material of clamp and screws Hot-dip galvanized steel / stainless steel
Weight (kg)[lb]
1.1[2.43]
Please note: Kathrein does not recommend to use counter nuts.The additional nuts supplied are only meant as spares.
All dimensions in mm and [inches]
152 [5.98]
100 [3.94]40 [1.57]
72 [2.83]
35 [1.38]
64 [2.52]
125 [4.92]
40 [1
.57]
20–
25
[0.7
9–
0.98
]
42–115
[1.65–4.53]
M10 MA = 25 Nm
M8 MA = 20 Nm
20–25
[0.79–0.98]
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected]
All specifications are subject to change without notice.The latest specifications are available at www.kathreinusa.com
Type No. 86010153Protocols compliant to AISG 1.1 and 3GPP/AISG 2.0Logical interface ex factory 1) 3GPP/AISG 2.0Operates as Single RETs or Multi RETEx factory Single RETsInput voltage range V 10 ... 30 (pin 1, pin 6)Power consumption W < 0.5 (stand by); < 10 (motor activated)Connectors 2 x 8 pin connector according to IEC 60130-9; according to AISG
Daisy chain in: male; Daisy chain out: femaleHardware interfaces RS 485A/B (pin 5, pin 3);
power supply (pin 1, pin 6); DC return (pin 7);according to AISG / 3GPP
Adjustment time (full range)
sec 40(typically, depending on antenna type)
Adjustment cycles > 50,000Temperature range °C –40 … +60Protection class IP 24 (installed)Lightning protection AISG interface (each pin)
2.5 kA (10/350 µs)8 kA (8/20 µs)
Housing material Profi le: Aluminum anodized; cover: Aluminum die cast coatedWeight g
lb3500.77
Packing size(H x W x D)
mminches
245 x 93 x 1029.6 x 3.6 x 4
Dimensions (H x W x D)
mminches
142 x 71 x 50.45.6 x 2.8 x 2
1) The protocol of the logical interface can be switched from 3GPP/AISG 2.0 to AISG 1.1 with a vendorspecifi c command. Start-up operation of the FlexRET is only possible in a RET system supporting3GPP/AISG 2.0!
1) Please note:If the Primary which controls the FlexRET system does not support the default ex-factory interfacesetting, then the RCU must be switched to the appropriate standard of the Primary before installation.Please contact Kathrein for further information.
If the FlexRET of an antenna has to be replaced, the FlexRET gets the information stored in the antennaafter power on automatically. It is not necessary to confi gurate the FlexRET manually.
Standards: EN 60950-1 (Safety)EN 60950-22 (Safety – Equipment installed outdoor)EN 55022 (Emission)EN 55024 (Immunity)ETS 300019-1-4 (Environmental)UL 60950-1; 1st edition
Certifi cation: CE, FCC
Scope of supply: FlexRET
Optional: Site Sharing Adapter (86010154 or 86010155) to create independent logial interfaces at one antenna or site. Makes it possible to operate with more than one independent Node B.
Please note:In general, the addressing of the FlexRET is automatically performed. Only in case the FlexRET is manually addressed, the serial number has to be extended by the corresponding colour coding extension (e.g. CSG351234-R1). The respective information can be found on the site documentation which is included in the scope of supply.
86010153 Page 1 of 4
936.
4643
/b
Sub
ject
to
alte
ratio
n.FlexRET
A fl exible, integrated solution for adjusting the electrical downtilt of Kathrein FlexRET antennas.
● Compliant to AISG 1.1 and 3GPP/AISG 2.0 ● Daisy Chain feasibility● Single RETs or Multi RET displayed ● Pre-confi gurated
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected]
All specifications are subject to change without notice.The latest specifications are available at www.kathreinusa.com
Page 2 of 4 86010153
936.
4643
/b
Sub
ject
to
alte
ratio
n.
FlexRET
Startup of FlexRETThe FlexRET module included in the antenna is preconfi gured with the following information: Antenna model no., Antenna Serial no., Antenna confi guration data. After connecting a control cable and scanning the antenna line devices (ALD) the used primary (e.g. NodeB, ALC, etc.) will fi nd the FlexRET. You only need to insert your additional data.
Connecting the control cables:
Connect a control cable to the daisy chain input of the FlexRET. The tightening torque for fi xing the connector must be 0.5 – 1.0 Nm (‘hand-tightened’).The connector should be tightened by hand or by a special torque screw driver (order no. 85010080).See also data sheet for Kathrein AISG-cable (86010007, ...). Please note: To ensure the tightness of the RET System, Kathrein recommend the use of Kathrein components only.Please note: If the daisy chain output is not used, do not remove the protection cap.
For daisy chain operation, remove the protection cap and attach a control cable to interconnect with the daisy chain input of the subsequent FlexRET or external RCU.Please note: Do not remove the protection cap on the daisy chain output of the last FlexRET or RCU device.
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected]
All specifications are subject to change without notice.The latest specifications are available at www.kathreinusa.com
86010153 Page 3 of 4
936.
4643
/b
Sub
ject
to
alte
ratio
n.FCC – Statements
���������������
���� �������
������������ ������������������������������������� ������������������������������������������������ �!�"�������������#�����������������������������$�����!%"������������������ ����#�������������������$�����������������������������#����������������� ���������
���� ��������
&��� �������'�� ������������������������������������ �#�����������������������������(�������������$� ����������� ������������������)����������������������������������� ����������������� ��������������������������������������������������������������������������'�� ��������������$������������������������������'���#������#����$����������������������������������������������������������$���#�������������������������������������������������*�����$���������������������������������������������������������� �����������������������+��������'�� ������������������������������������������������������������ ����$������������������������#��������������'�� ���������������$����������������������������#���������������������������#�������������������������������������� �
,)����������������������������������������,+������������� ���������������������'�� �����������������,������������'�� ����������������������������������������������������������������������������������,��������������������������- �������������.�/����������������� ��
���������������������������
������������ ����������+������#�������������0�-�� ��)11���������!�"��� ������������������������������������������������ !�"�������������#���������������������$�����!%"������������������ ����#������������$�����������������������������#����������������� ���������������������
2�� �3������ ��������������������-��&)��4+����������������� ����������-�� ��������������-�� �������������24�- ���������������������3����-����-�������������������� �!�"��4� �������������� ��� ���������������������$����!%"��4����������������4� ������������� �������������������������3�����'�������$��5���������������������������� �������4����� ���������������������������
���������
�����������(���������� ��������� �������������������+�610778��
����� ���������3��'���������������(�������������9����������&:(0778������������
�
���� ������� !�"���#�������$�
;<�#=�����������������������������- �����#�� ������#����� ���#���� �������������� �����������������������>����������#����� �����������'�� ������
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected]
Page 4 of 4 86010153
936.
4643
/b
Sub
ject
to
alte
ratio
n.
FCC – Statements
Compliance Information Statement (Declaration of Conformity Procedure)
Model Name: FlexRET FCC ID SP3-86010153
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected]
All specifications are subject to change without notice.The latest specifications are available at www.kathreinusa.com
Responsible Party: Kathrein USA
Address: Greenway Plaza II 2400 Lakeside Blvd. Suite 650Richardson, Texas 75082
Telephone: (01+) 214.238.8800
Type of equipment: