7ut613 v4 6 Var f14 Ang2 Prn

Embed Size (px)

DESCRIPTION

proe

Citation preview

SIMATIC ANG UNIDAD 2 / Canal B / 7UT613 V4.6 Var F14/7UT613 19.03.15 17:03:03----------------------------------------------------------------------------------------------- +---------------------------------------------------------------------------------------------+| ANG UNIDAD 2 / Canal B / 7UT613 V4.6 Var F14 || || MLFB: 7UT6135*EB221BA1 || Parameter set version: V04.61.04 || Device path: C:\Siemens\Digsi4\D4PROJ\Ang_un_1\P7DI\GV\ST\00000002 || Author: || Creation date: 19.03.15 16:34:49 || Last modified: 19.03.15 17:02:52 || Operating mode: Offline || Comment: || Setting values in: Secondary value description || |+---------------------------------------------------------------------------------------------+ -----------------------------------------------------------------------------------------------P R I N T - C O N T E N T S1 Device Configuration2 Configuration - complete (sorted by line)2.1 Indications2.1.1 Device2.1.2 Power System Data 12.1.3 Oscillographic Fault Records2.1.4 Power System Data 22.1.5 Differential Protection2.1.6 Restricted Earth Fault Protection2.1.7 General O/C2.1.8 Time overcurrent Phase2.1.9 Time overcurrent Earth2.1.10 Disconnect measurment location2.1.11 Measurement Supervision2.1.12 Supervision2.1.13 External Annunciations of Transformer2.1.14 Control Authorization2.1.15 Threshold-Switch2.1.16 Statistics2.1.17 Set Points (Statistic)2.2 Commands2.3 Measured values2.3.1 Measurement2.3.2 Diff- and Rest. Measurement2.4 Metered values2.4.1 Energy2.5 Display after fault3 Configuration - short (column-oriented)3.1 Binary inputs3.2 Binary outputs3.3 LEDs3.4 CFC3.5 Function keys3.6 Buffer3.6.1 Operational indication buffer3.6.2 Sensitive ground fault indication buffer3.6.3 Trip log3.6.4 Event value buffer3.7 Display3.8 System interface: IEC60870-5-1034 Interfaces4.1 Serial interface on PC:4.2 VD addresses4.3 Operator Interface4.4 Service interface4.5 IEC 103 on device 5 Passwords6 General Device Settings6.1 Group Device; Group General7 Power System Data 17.1 Group Power System Data 1; Group CT-Numbers7.2 Group Power System Data 1; Group CT-Assign7.3 Group Power System Data 1; Group Power System7.4 Group Power System Data 1; Group Transf.7.5 Group Power System Data 1; Group Funct.7.6 Group Power System Data 1; Group CT's7.7 Group Power System Data 1; Group CB8 Oscillographic Fault Records8.1 Group Oscillographic Fault Records; Group Osc. Fault Rec.9 Settings groups9.1 Group Power System Data 2; Group PoleOpen Detect9.2 Group Differential Protection; Group General9.3 Group Differential Protection; Group I-Diff9.4 Group Differential Protection; Group Characteristic9.5 Group Differential Protection; Group Inrush 2.HM9.6 Group Differential Protection; Group Restr. n.HM9.7 Group Restricted Earth Fault Protection; Group General9.8 Group Restricted Earth Fault Protection; Group Settings9.9 Group Time overcurrent Phase; Group General9.10 Group Time overcurrent Phase; Group DMT9.11 Group Time overcurrent Phase; Group IDMT9.12 Group Time overcurrent Phase; Group Inrush9.13 Group Time overcurrent Earth; Group General9.14 Group Time overcurrent Earth; Group DMT9.15 Group Time overcurrent Earth; Group Inrush9.16 Group Measurement Supervision; Group General9.17 Group Measurement Supervision; Group Balance I M19.18 Group Measurement Supervision; Group Balance I M29.19 Group Measurement Supervision; Group Balance I M39.20 Group Supervision; Group General9.21 Group Measurement; Group Measurement10 Time Synchronization11 Annunciation11.1 Event Log11.2 Trip Log11.3 General Interrogation11.4 Spontaneous Annunciation11.5 Statistics11.6 Set Points (Statistic)12 Measurement12.1 Operational values, primary12.2 Operational current of sides, primary12.3 Operational values, secondary12.4 Angles12.5 Operational Percent12.6 Operational current of sides, I/nS12.7 Differential and Restraint Current12.8 User Defined12.9 Energy12.10 Set Points (Measured Values)-----------------------------------------------------------------------------------------------1 Device Configuration +------+-------------------------------------+-----------------------------+| No. | Function | Scope |+------+-------------------------------------+-----------------------------+| 0103 | Setting Group Change Option | Disabled |+------+-------------------------------------+-----------------------------+| 0105 | Protection Object | 3 phase Transformer |+------+-------------------------------------+-----------------------------+| 0112 | Differential Protection | Enabled |+------+-------------------------------------+-----------------------------+| 0113 | Restricted earth fault protection | Enabled |+------+-------------------------------------+-----------------------------+| 0114 | Restricted earth fault protection 2 | Disabled |+------+-------------------------------------+-----------------------------+| 0117 | Cold Load Pickup | Disabled |+------+-------------------------------------+-----------------------------+| 0120 | DMT / IDMT Phase | Time Overcurrent Curve IEC |+------+-------------------------------------+-----------------------------+| 0130 | DMT / IDMT Phase 2 | Disabled |+------+-------------------------------------+-----------------------------+| 0132 | DMT / IDMT Phase 3 | Disabled |+------+-------------------------------------+-----------------------------+| 0122 | DMT / IDMT 3I0 | Disabled |+------+-------------------------------------+-----------------------------+| 0134 | DMT / IDMT 3I0 2 | Disabled |+------+-------------------------------------+-----------------------------+| 0136 | DMT / IDMT 3I0 3 | Disabled |+------+-------------------------------------+-----------------------------+| 0124 | DMT / IDMT Earth | Definite Time only |+------+-------------------------------------+-----------------------------+| 0138 | DMT / IDMT Earth 2 | Disabled |+------+-------------------------------------+-----------------------------+| 0127 | DMT 1Phase | Disabled |+------+-------------------------------------+-----------------------------+| 0140 | Unbalance Load (Negative Sequence) | Disabled |+------+-------------------------------------+-----------------------------+| 0142 | Thermal Overload Protection | Disabled |+------+-------------------------------------+-----------------------------+| 0144 | Thermal Overload Protection 2 | Disabled |+------+-------------------------------------+-----------------------------+| 0170 | Breaker Failure Protection | Disabled |+------+-------------------------------------+-----------------------------+| 0171 | Breaker Failure Protection 2 | Disabled |+------+-------------------------------------+-----------------------------+| 0180 | Disconnect measurment location | Enabled |+------+-------------------------------------+-----------------------------+| 0181 | Measured Values Supervision | Enabled |+------+-------------------------------------+-----------------------------+| 0182 | Trip Circuit Supervision | Disabled |+------+-------------------------------------+-----------------------------+| 0186 | External Trip Function 1 | Disabled |+------+-------------------------------------+-----------------------------+| 0187 | External Trip Function 2 | Disabled |+------+-------------------------------------+-----------------------------+2 Configuration - complete (sorted by line)No filter 2.1 Indications 2.1.1 Device >Synchronize Internal Real Time Clock Type: SP_Ev - Single point indication event >Reset LED Type: SP - Single point indication Reset LED Type: IntSP - Internal single point indication Configured to source: System interface Configured to destination: Operation Buffer: I System interface >Test mode Type: SP - Single point indication Test mode Type: IntSP - Internal single point indication Configured to destination: Operation Buffer: IO >Stop data transmission Type: SP - Single point indication Stop data transmission Type: IntSP - Internal single point indication Configured to destination: Operation Buffer: IO Unlock data transmission via BI Type: IntSP - Internal single point indication Configured to source: CFC >Back Light on Type: SP - Single point indication Configured to destination: Operation Buffer: IO Device is Operational and Protecting Type: OUT - Output indication Configured to destination: Operation Buffer: IO System interface At Least 1 Protection Funct. is Active Type: IntSP - Internal single point indication Configured to destination: Operation Buffer: IO Reset Device Type: OUT - Output indication Configured to destination: System interface Initial Start of Device Type: OUT - Output indication Configured to destination: Operation Buffer: I Resume Type: OUT - Output indication Configured to destination: Operation Buffer: I Daylight Saving Time Type: OUT - Output indication Configured to destination: Operation Buffer: IO Clock Synchronization Type: IntSP_Ev - Internal single point indication event Configured to source: System interface Configured to destination: System interface Setting calculation is running Type: OUT - Output indication Configured to destination: Operation Buffer: IO Settings Check Type: OUT - Output indication Level-2 change Type: OUT - Output indication Configured to destination: Operation Buffer: IO Frequency out of range Type: OUT - Output indication Configured to destination: Operation Buffer: IO Chatter ON Type: OUT - Output indication Configured to destination: Operation Buffer: IO Hardware Test Mode Type: IntSP - Internal single point indication Configured to destination: Operation Buffer: IO Warn: Limit of Memory Data exceeded Type: OUT - Output indication Configured to destination: Operation Buffer: IO Warn: Limit of Memory Parameter exceeded Type: OUT - Output indication Configured to destination: Operation Buffer: IO Warn: Limit of Memory Operation exceeded Type: OUT - Output indication Configured to destination: Operation Buffer: IO Warn: Limit of Memory New exceeded Type: OUT - Output indication Configured to destination: Operation Buffer: IO 2.1.2 Power System Data 1 >Reverse Phase Rotation Type: SP - Single point indication Configured to destination: Operation Buffer: IO Phase Rotation L1L2L3 Type: OUT - Output indication Configured to destination: Operation Buffer: IO Phase Rotation L1L3L2 Type: OUT - Output indication Configured to destination: Operation Buffer: IO 2.1.3 Oscillographic Fault Records >Trigger Waveform Capture Type: SP - Single point indication Configured to source: CFC Fault Recording Start Type: IntSP - Internal single point indication Configured to destination: Operation Buffer: IO Fault recording is running Type: OUT - Output indication 2.1.4 Power System Data 2 Fault in configuration / setting Type: OUT - Output indication Configured to destination: Operation Buffer: IO Gen.err.: Inconsistency group/connection Type: OUT - Output indication Configured to destination: Operation Buffer: I Gen.err.: Sev. earth-CTs with equal typ Type: OUT - Output indication Configured to destination: Operation Buffer: I Gen.err.: Number of sides / measurements Type: OUT - Output indication Configured to destination: Operation Buffer: I General: Adaption factor CT M1 Type: VI - Value indication Configured to destination: Operation Buffer: IO General: Adaption factor CT M2 Type: VI - Value indication Configured to destination: Operation Buffer: IO General: Adaption factor CT M3 Type: VI - Value indication Configured to destination: Operation Buffer: IO parameter too low: Type: VI - Value indication Configured to destination: Operation Buffer: IO parameter too high: Type: VI - Value indication Configured to destination: Operation Buffer: IO setting fault: Type: VI - Value indication Configured to destination: Operation Buffer: IO >Manual close signal measurement loc. 1 Type: SP - Single point indication Manual close signal meas.loc. 1 detected Type: OUT - Output indication Configured to destination: Operation Buffer: I >Manual close signal measurement loc. 2 Type: SP - Single point indication Manual close signal meas.loc. 2 detected Type: OUT - Output indication Configured to destination: Operation Buffer: I >Manual close signal measurement loc. 3 Type: SP - Single point indication Manual close signal meas.loc. 3 detected Type: OUT - Output indication Configured to destination: Operation Buffer: I >Manual close signal side 1 Type: SP - Single point indication Manual close signal side 1 is detected Type: OUT - Output indication Configured to destination: Operation Buffer: I >Manual close signal side 2 Type: SP - Single point indication Manual close signal side 2 is detected Type: OUT - Output indication Configured to destination: Operation Buffer: I >Manual close signal side 3 Type: SP - Single point indication Manual close signal side 3 is detected Type: OUT - Output indication Configured to destination: Operation Buffer: I Relay PICKUP Type: OUT - Output indication Configured to destination: LED: L 1 Trip log: I System interface Relay GENERAL TRIP command Type: OUT - Output indication Configured to destination: Trip log: I >Quitt Lock Out: General Trip Type: IntSP - Internal single point indication Lock Out: General TRIP Type: IntSP - Internal single point indication Time from Pickup to drop out Type: VI - Value indication Time from Pickup to TRIP Type: VI - Value indication Protection ON/OFF (via system port) Type: IntSP - Internal single point indication Configured to destination: Operation Buffer: IO Primary fault current IL1 meas. loc. 1 Type: VI - Value indication Primary fault current IL2 meas. loc. 1 Type: VI - Value indication Primary fault current IL3 meas. loc. 1 Type: VI - Value indication Primary fault current IL1 meas. loc. 2 Type: VI - Value indication Primary fault current IL2 meas. loc. 2 Type: VI - Value indication Primary fault current IL3 meas. loc. 2 Type: VI - Value indication Primary fault current IL1 meas. loc. 3 Type: VI - Value indication Primary fault current IL2 meas. loc. 3 Type: VI - Value indication Primary fault current IL3 meas. loc. 3 Type: VI - Value indication Primary fault current IL1 side1 Type: VI - Value indication Primary fault current IL2 side1 Type: VI - Value indication Primary fault current IL3 side1 Type: VI - Value indication Primary fault current IL1 side2 Type: VI - Value indication Primary fault current IL2 side2 Type: VI - Value indication Primary fault current IL3 side2 Type: VI - Value indication Primary fault current IL1 side3 Type: VI - Value indication Primary fault current IL2 side3 Type: VI - Value indication Primary fault current IL3 side3 Type: VI - Value indication 2.1.5 Differential Protection >BLOCK differential protection Type: SP - Single point indication Differential protection is switched OFF Type: OUT - Output indication Configured to destination: Operation Buffer: IO Differential protection is BLOCKED Type: OUT - Output indication Configured to destination: Operation Buffer: IO Trip log: IO Differential protection is ACTIVE Type: OUT - Output indication Configured to destination: Operation Buffer: IO Diff err.: adverse Adaption factor CT Type: OUT - Output indication Configured to destination: Operation Buffer: I Diff. prot: Adaption factor CT M1 Type: VI - Value indication Configured to destination: Operation Buffer: IO Diff. prot: Adaption factor CT M2 Type: VI - Value indication Configured to destination: Operation Buffer: IO Diff. prot: Adaption factor CT M3 Type: VI - Value indication Configured to destination: Operation Buffer: IO Diff. prot: Adaption factor aux. CT IX1 Type: VI - Value indication Configured to destination: Operation Buffer: IO Differential protection picked up Type: OUT - Output indication Configured to destination: Trip log: IO System interface Diff: Blocked by 2.Harmon. L1 Type: OUT - Output indication Configured to destination: Trip log: IO Diff: Blocked by 2.Harmon. L2 Type: OUT - Output indication Configured to destination: Trip log: IO Diff: Blocked by 2.Harmon. L3 Type: OUT - Output indication Configured to destination: Trip log: IO Diff: Blocked by n.Harmon. L1 Type: OUT - Output indication Configured to destination: Trip log: IO Diff: Blocked by n.Harmon. L2 Type: OUT - Output indication Configured to destination: Trip log: IO Diff: Blocked by n.Harmon. L3 Type: OUT - Output indication Configured to destination: Trip log: IO Diff. prot.: Blocked by ext. fault L1 Type: OUT - Output indication Configured to destination: Trip log: IO Diff. prot.: Blocked by ext. fault L2 Type: OUT - Output indication Configured to destination: Trip log: IO Diff. prot.: Blocked by ext. fault.L3 Type: OUT - Output indication Configured to destination: Trip log: IO Diff: Crossblock by 2.Harmonic Type: OUT - Output indication Configured to destination: Trip log: IO Diff: Crossblock by n.Harmonic Type: OUT - Output indication Configured to destination: Trip log: IO Diff: Crossblock by ext. fault Type: OUT - Output indication Configured to destination: Trip log: IO Diff: Increase of char. phase (start) L1 Type: OUT - Output indication Configured to destination: Operation Buffer: IO Trip log: IO Diff: Increase of char. phase (start) L2 Type: OUT - Output indication Configured to destination: Operation Buffer: IO Trip log: IO Diff: Increase of char. phase (start) L3 Type: OUT - Output indication Configured to destination: Operation Buffer: IO Trip log: IO Diff: DC L1 Type: OUT - Output indication Configured to destination: Trip log: IO Diff: DC L2 Type: OUT - Output indication Configured to destination: Trip log: IO Diff: DC L3 Type: OUT - Output indication Configured to destination: Trip log: IO Diff: Increase of char. phase (DC) Type: OUT - Output indication Configured to destination: Trip log: IO Differential protection TRIP Type: OUT - Output indication Configured to destination: BO: U 7,U 1,U 6 LED: L 2 System interface Differential protection: TRIP L1 Type: OUT - Output indication Configured to destination: System interface Differential protection: TRIP L2 Type: OUT - Output indication Configured to destination: System interface Differential protection: TRIP L3 Type: OUT - Output indication Configured to destination: System interface Diff. prot.: IDIFF> L1 (without Tdelay) Type: OUT - Output indication Configured to destination: Trip log: IO Diff. prot.: IDIFF> L2 (without Tdelay) Type: OUT - Output indication Configured to destination: Trip log: IO Diff. prot.: IDIFF> L3 (without Tdelay) Type: OUT - Output indication Configured to destination: Trip log: IO Diff. prot: IDIFF>> L1 (without Tdelay) Type: OUT - Output indication Configured to destination: Trip log: IO Diff. prot: IDIFF>> L2 (without Tdelay) Type: OUT - Output indication Configured to destination: Trip log: IO Diff. prot: IDIFF>> L3 (without Tdelay) Type: OUT - Output indication Configured to destination: Trip log: IO Differential prot.: TRIP by IDIFF> Type: OUT - Output indication Configured to destination: Trip log: I System interface Differential prot.: TRIP by IDIFF>> Type: OUT - Output indication Configured to destination: Trip log: I System interface Diff. curr. in L1 at trip without Tdelay Type: VI - Value indication Configured to destination: Trip log: IO Diff. curr. in L2 at trip without Tdelay Type: VI - Value indication Configured to destination: Trip log: IO Diff. curr. in L3 at trip without Tdelay Type: VI - Value indication Configured to destination: Trip log: IO Restr.curr. in L1 at trip without Tdelay Type: VI - Value indication Configured to destination: Trip log: IO Restr.curr. in L2 at trip without Tdelay Type: VI - Value indication Configured to destination: Trip log: IO Restr.curr. in L3 at trip without Tdelay Type: VI - Value indication Configured to destination: Trip log: IO 2.1.6 Restricted Earth Fault Protection >BLOCK restricted earth fault prot. Type: SP - Single point indication Restricted earth fault is switched OFF Type: OUT - Output indication Configured to destination: Operation Buffer: IO Restricted earth fault is BLOCKED Type: OUT - Output indication Configured to destination: Operation Buffer: IO Trip log: IO Restricted earth fault is ACTIVE Type: OUT - Output indication Configured to destination: Operation Buffer: IO Restr. earth flt.: picked up Type: OUT - Output indication Configured to destination: Trip log: IO System interface Restr. earth flt.: Time delay started Type: OUT - Output indication Configured to destination: Trip log: IO Restr. earth flt.: TRIP Type: OUT - Output indication Configured to destination: BO: U 7,U 2 LED: L 3 Trip log: I System interface REF: Value D at trip (without Tdelay) Type: VI - Value indication Configured to destination: Trip log: IO REF: Value S at trip (without Tdelay) Type: VI - Value indication Configured to destination: Trip log: IO REF: Adaption factor CT starpnt. wind. Type: VI - Value indication Configured to destination: Operation Buffer: IO REF err.: adverse Adaption factor CT Type: OUT - Output indication Configured to destination: Operation Buffer: I REF err.: No starpoint CT Type: OUT - Output indication Configured to destination: Operation Buffer: I REF err.: Not available for this object Type: OUT - Output indication Configured to destination: Operation Buffer: I 2.1.7 General O/C Time Overcurrent picked up Type: OUT - Output indication Configured to destination: Trip log: IO System interface Time Overcurrent TRIP Type: OUT - Output indication Configured to destination: Trip log: I System interface 2.1.8 Time overcurrent Phase 50/51 Type: OUT - Output indication Configured to source: CFC Configured to destination: LED: L 4 Operation Buffer: IO System interface >BLOCK Phase time overcurrent Type: SP - Single point indication >BLOCK time overcurrent Phase InRush Type: SP - Single point indication Configured to destination: Operation Buffer: IO Trip log: IO System interface Time Overcurrent Phase is OFF Type: OUT - Output indication Configured to destination: Operation Buffer: IO System interface Time Overcurrent Phase is BLOCKED Type: OUT - Output indication Configured to destination: Operation Buffer: IO Trip log: IO System interface Time Overcurrent Phase is ACTIVE Type: OUT - Output indication Configured to destination: Operation Buffer: IO System interface Phase L1 InRush detected Type: OUT - Output indication Configured to destination: Trip log: IO Phase L2 InRush detected Type: OUT - Output indication Configured to destination: Trip log: IO Phase L3 InRush detected Type: OUT - Output indication Configured to destination: Trip log: IO Cross blk: PhX blocked PhY Type: OUT - Output indication Configured to destination: Trip log: IO Time Overcurrent Phase L1 picked up Type: OUT - Output indication Configured to destination: Trip log: IO System interface Time Overcurrent Phase L2 picked up Type: OUT - Output indication Configured to destination: Trip log: IO System interface Time Overcurrent Phase L3 picked up Type: OUT - Output indication Configured to destination: Trip log: IO System interface Phase L1 InRush picked up Type: OUT - Output indication Configured to destination: Trip log: IO System interface Phase L2 InRush picked up Type: OUT - Output indication Configured to destination: Trip log: IO System interface Phase L3 InRush picked up Type: OUT - Output indication Configured to destination: Trip log: IO System interface >BLOCK I>> Type: SP - Single point indication I>> BLOCKED Type: OUT - Output indication Configured to destination: Operation Buffer: IO Trip log: IO I>> picked up Type: OUT - Output indication Configured to destination: Trip log: IO System interface I>> Time Out Type: OUT - Output indication I>> TRIP Type: OUT - Output indication Configured to destination: BO: U 4,U 8 LED: L 4 Trip log: I CFC System interface >BLOCK I> Type: SP - Single point indication I> BLOCKED Type: OUT - Output indication Configured to destination: Operation Buffer: IO Trip log: IO I> picked up Type: OUT - Output indication Configured to destination: Trip log: IO System interface I> InRush picked up Type: OUT - Output indication Configured to destination: Trip log: IO I> Time Out Type: OUT - Output indication I> TRIP Type: OUT - Output indication Configured to destination: BO: U 4,U 8 LED: L 4 Trip log: I CFC System interface >BLOCK Ip Type: SP - Single point indication Ip BLOCKED Type: OUT - Output indication Configured to destination: Operation Buffer: IO Trip log: IO Ip picked up Type: OUT - Output indication Configured to destination: Trip log: IO System interface Ip InRush picked up Type: OUT - Output indication Configured to destination: Trip log: IO Ip Time Out Type: OUT - Output indication Ip TRIP Type: OUT - Output indication Configured to destination: BO: U 4,U 8 LED: L 4 Trip log: I CFC System interface O/C Phase: Not available for this object Type: OUT - Output indication Configured to destination: Operation Buffer: I 2.1.9 Time overcurrent Earth >BLOCK Earth time overcurrent Type: SP - Single point indication >BLOCK time overcurrent Earth InRush Type: SP - Single point indication Configured to destination: Operation Buffer: IO Trip log: IO Time Overcurrent Earth is OFF Type: OUT - Output indication Configured to destination: Operation Buffer: IO Time Overcurrent Earth is BLOCKED Type: OUT - Output indication Configured to destination: Operation Buffer: IO Trip log: IO Time Overcurrent Earth is ACTIVE Type: OUT - Output indication Configured to destination: Operation Buffer: IO Time Overcurrent Earth picked up Type: OUT - Output indication Configured to destination: Trip log: IO System interface Earth InRush picked up Type: OUT - Output indication Configured to destination: Trip log: IO System interface >BLOCK IE>> Type: SP - Single point indication IE>> BLOCKED Type: OUT - Output indication Configured to destination: Operation Buffer: IO Trip log: IO IE>> picked up Type: OUT - Output indication Configured to destination: Trip log: IO System interface IE>> Time Out Type: OUT - Output indication IE>> TRIP Type: OUT - Output indication Configured to destination: Trip log: I System interface >BLOCK IE> Type: SP - Single point indication IE> BLOCKED Type: OUT - Output indication Configured to destination: Operation Buffer: IO Trip log: IO IE> picked up Type: OUT - Output indication Configured to destination: Trip log: IO System interface IE> InRush picked up Type: OUT - Output indication Configured to destination: Trip log: IO System interface IE> Time Out Type: OUT - Output indication IE> TRIP Type: OUT - Output indication Configured to destination: BO: U 3 LED: L 5 Trip log: I System interface O/C Earth err.: No auxiliary CT assigned Type: OUT - Output indication Configured to destination: Operation Buffer: I 2.1.10 Disconnect measurment location >disconnect without test: current = 0 Type: SP - Single point indication Configured to destination: Operation Buffer: IO >disconnect measurment location 1 Type: SP - Single point indication Configured to destination: Operation Buffer: IO Measurment location 1 is disconnected Type: OUT - Output indication Configured to destination: Operation Buffer: IO >disconnect measurment location 2 Type: SP - Single point indication Configured to destination: Operation Buffer: IO Measurment location 2 is disconnected Type: OUT - Output indication Configured to destination: Operation Buffer: IO >disconnect measurment location 3 Type: SP - Single point indication Configured to destination: Operation Buffer: IO Measurment location 3 is disconnected Type: OUT - Output indication Configured to destination: Operation Buffer: IO 2.1.11 Measurement Supervision Failure: General Current Supervision Type: OUT - Output indication Configured to destination: Operation Buffer: IO Failure: Current Balance Type: OUT - Output indication Configured to destination: Operation Buffer: IO System interface Fail.: Current Balance meas. location 1 Type: OUT - Output indication Configured to destination: Operation Buffer: IO Fail.: Current Balance meas. location 2 Type: OUT - Output indication Configured to destination: Operation Buffer: IO Fail.: Current Balance meas. location 3 Type: OUT - Output indication Configured to destination: Operation Buffer: IO Failure: Phase Sequence Type: OUT - Output indication Configured to destination: Operation Buffer: IO Failure: Phase Sequence Current Type: OUT - Output indication Configured to destination: Operation Buffer: IO System interface Failure: Phase Sequence I meas. loc. 1 Type: OUT - Output indication Configured to destination: Operation Buffer: IO Failure: Phase Sequence I meas. loc. 2 Type: OUT - Output indication Configured to destination: Operation Buffer: IO Failure: Phase Sequence I meas. loc. 3 Type: OUT - Output indication Configured to destination: Operation Buffer: IO 2.1.12 Supervision Disturbance CFC Type: OUT - Output indication Configured to destination: Operation Buffer: IO Event lost Type: OUT_Ev - Output indication event Configured to destination: Operation Buffer: I Flag Lost Type: OUT - Output indication Configured to destination: Operation Buffer: I Error with a summary alarm Type: OUT - Output indication Configured to destination: System interface Error: Measurement system Type: OUT - Output indication Configured to destination: Operation Buffer: IO Error Board 0 Type: OUT - Output indication Configured to destination: Operation Buffer: IO Error Board 1 Type: OUT - Output indication Configured to destination: Operation Buffer: IO Error Board 2 Type: OUT - Output indication Configured to destination: Operation Buffer: IO Error Board 3 Type: OUT - Output indication Configured to destination: Operation Buffer: IO Error Board 4 Type: OUT - Output indication Configured to destination: Operation Buffer: IO Error Board 5 Type: OUT - Output indication Configured to destination: Operation Buffer: IO Error Board 6 Type: OUT - Output indication Configured to destination: Operation Buffer: IO Error Board 7 Type: OUT - Output indication Configured to destination: Operation Buffer: IO Error:1A/5Ajumper different from setting Type: OUT - Output indication Configured to destination: Operation Buffer: IO Err: inconsist. jumper/setting CT M1 Type: OUT - Output indication Configured to destination: Operation Buffer: IO Err: inconsist. jumper/setting CT M2 Type: OUT - Output indication Configured to destination: Operation Buffer: IO Err: inconsist. jumper/setting CT M3 Type: OUT - Output indication Configured to destination: Operation Buffer: IO Err: inconsist. jumper/setting CT IX1 Type: OUT - Output indication Configured to destination: Operation Buffer: IO Error: Offset Type: OUT - Output indication Configured to destination: Operation Buffer: IO Failure: disconnect measurment location Type: OUT - Output indication Configured to destination: Operation Buffer: IO Broken wire is switched OFF Type: OUT - Output indication Configured to destination: Operation Buffer: IO Broken wire detected Type: OUT - Output indication Configured to destination: Operation Buffer: IO System interface Broken wire IL1 measurement location 1 Type: OUT - Output indication Configured to destination: Operation Buffer: IO System interface Broken wire IL2 measurement location 1 Type: OUT - Output indication Configured to destination: Operation Buffer: IO System interface Broken wire IL3 measurement location 1 Type: OUT - Output indication Configured to destination: Operation Buffer: IO System interface Broken wire IL1 measurement location 2 Type: OUT - Output indication Configured to destination: Operation Buffer: IO System interface Broken wire IL2 measurement location 2 Type: OUT - Output indication Configured to destination: Operation Buffer: IO System interface Broken wire IL3 measurement location 2 Type: OUT - Output indication Configured to destination: Operation Buffer: IO System interface Broken wire IL1 measurement location 3 Type: OUT - Output indication Configured to destination: Operation Buffer: IO System interface Broken wire IL2 measurement location 3 Type: OUT - Output indication Configured to destination: Operation Buffer: IO System interface Broken wire IL3 measurement location 3 Type: OUT - Output indication Configured to destination: Operation Buffer: IO System interface Alarm Summary Event Type: OUT - Output indication Configured to destination: System interface Alarm: Analog input adjustment invalid Type: OUT - Output indication Configured to destination: Operation Buffer: IO Failure: Battery empty Type: OUT - Output indication Configured to destination: Operation Buffer: IO System interface Clock Synchronization Error Type: OUT - Output indication Configured to destination: Operation Buffer: IO Error: Communication Module B Type: OUT - Output indication Configured to destination: Operation Buffer: IO Error: Communication Module C Type: OUT - Output indication Configured to destination: Operation Buffer: IO Error: Communication Module D Type: OUT - Output indication Configured to destination: Operation Buffer: IO Incons. M1: CBaux open/ curr. persistent Type: OUT - Output indication Configured to destination: Operation Buffer: IO Incons. M2: CBaux open/ curr. persistent Type: OUT - Output indication Configured to destination: Operation Buffer: IO Incons. M3: CBaux open/ curr. persistent Type: OUT - Output indication Configured to destination: Operation Buffer: IO Incons. S1: CBaux open/ curr. persistent Type: OUT - Output indication Configured to destination: Operation Buffer: IO Incons. S2: CBaux open/ curr. persistent Type: OUT - Output indication Configured to destination: Operation Buffer: IO Incons. S3: CBaux open/ curr. persistent Type: OUT - Output indication Configured to destination: Operation Buffer: IO 2.1.13 External Annunciations of Transformer >Warning stage from gas in oil detector Type: SP - Single point indication Configured to destination: Operation Buffer: IO >Warning stage from Buchholz protection Type: SP - Single point indication Configured to destination: Operation Buffer: IO >Tripp. stage from Buchholz protection Type: SP - Single point indication Configured to destination: Operation Buffer: IO >Tank supervision from Buchh. protect. Type: SP - Single point indication Configured to destination: Operation Buffer: IO Pres_Trip Type: SP - Single point indication Configured to source: BI: H 1 Configured to destination: BO: U 5 LED: L 6 Operation Buffer: IO CFC System interface Wind_Temp Type: SP - Single point indication Configured to source: BI: H 2 Configured to destination: BO: U 5 LED: L 7 Operation Buffer: IO CFC System interface Oil Win_Te Type: SP - Single point indication Configured to source: BI: H 3 Configured to destination: BO: U 5 LED: L 8 Operation Buffer: IO CFC System interface 2.1.14 Control Authorization Control Authority Type: IntSP - Internal single point indication Configured to destination: Operation Buffer: IO Controlmode REMOTE Type: IntSP - Internal single point indication Configured to destination: Operation Buffer: IO Controlmode LOCAL Type: IntSP - Internal single point indication Configured to destination: Operation Buffer: IO 2.1.15 Threshold-Switch Threshold Value 1 Type: IntSP - Internal single point indication Configured to destination: Operation Buffer: IO 2.1.16 Statistics >BLOCK Op Counter Type: SP - Single point indication Configured to destination: Operation Buffer: IO Counter of operating hours Type: VI - Value indication Number of breaker TRIP commands Type: VI - Value indication Accumulation of interrupted curr. L1 M1 Type: VI - Value indication Accumulation of interrupted curr. L2 M1 Type: VI - Value indication Accumulation of interrupted curr. L3 M1 Type: VI - Value indication Accumulation of interrupted curr. L1 M2 Type: VI - Value indication Accumulation of interrupted curr. L2 M2 Type: VI - Value indication Accumulation of interrupted curr. L3 M2 Type: VI - Value indication Accumulation of interrupted curr. L1 M3 Type: VI - Value indication Accumulation of interrupted curr. L2 M3 Type: VI - Value indication Accumulation of interrupted curr. L3 M3 Type: VI - Value indication Accumulation of interrupted curr. L1 S1 Type: VI - Value indication Accumulation of interrupted curr. L2 S1 Type: VI - Value indication Accumulation of interrupted curr. L3 S1 Type: VI - Value indication Accumulation of interrupted curr. L1 S2 Type: VI - Value indication Accumulation of interrupted curr. L2 S2 Type: VI - Value indication Accumulation of interrupted curr. L3 S2 Type: VI - Value indication Accumulation of interrupted curr. L1 S3 Type: VI - Value indication Accumulation of interrupted curr. L2 S3 Type: VI - Value indication Accumulation of interrupted curr. L3 S3 Type: VI - Value indication 2.1.17 Set Points (Statistic) Set Point Operating Hours Type: OUT - Output indication Configured to destination: Operation Buffer: IO 2.2 Commands None 2.3 Measured values 2.3.1 Measurement Operat. meas. current IL1 meas. loc. 1 Type: MV - Measured value Configured to destination: System interface Operat. meas. current IL2 meas. loc. 1 Type: MV - Measured value Configured to destination: System interface Operat. meas. current IL3 meas. loc. 1 Type: MV - Measured value Configured to destination: System interface 3I0 (zero sequence) of meas. loc. 1 Type: MV - Measured value I1 (positive sequence) of meas. loc. 1 Type: MV - Measured value I2 (negative sequence) of meas. loc. 1 Type: MV - Measured value Operat. meas. current IL1 meas. loc. 2 Type: MV - Measured value Configured to destination: System interface Operat. meas. current IL2 meas. loc. 2 Type: MV - Measured value Configured to destination: System interface Operat. meas. current IL3 meas. loc. 2 Type: MV - Measured value Configured to destination: System interface 3I0 (zero sequence) of meas. loc. 2 Type: MV - Measured value I1 (positive sequence) of meas. loc. 2 Type: MV - Measured value I2 (negative sequence) of meas. loc. 2 Type: MV - Measured value Operat. meas. current IL1 meas. loc. 3 Type: MV - Measured value Configured to destination: System interface Operat. meas. current IL2 meas. loc. 3 Type: MV - Measured value Configured to destination: System interface Operat. meas. current IL3 meas. loc. 3 Type: MV - Measured value Configured to destination: System interface 3I0 (zero sequence) of meas. loc. 3 Type: MV - Measured value I1 (positive sequence) of meas. loc. 3 Type: MV - Measured value I2 (negative sequence) of meas. loc. 3 Type: MV - Measured value Operat. meas. current IL1 side 1 Type: MV - Measured value Configured to destination: System interface Operat. meas. current IL2 side 1 Type: MV - Measured value Configured to destination: System interface Operat. meas. current IL3 side 1 Type: MV - Measured value Configured to destination: System interface 3I0 (zero sequence) of side 1 Type: MV - Measured value I1 (positive sequence) of side 1 Type: MV - Measured value I2 (negative sequence) of side 1 Type: MV - Measured value Operat. meas. current IL1 side 2 Type: MV - Measured value Configured to destination: System interface Operat. meas. current IL2 side 2 Type: MV - Measured value Configured to destination: System interface Operat. meas. current IL3 side 2 Type: MV - Measured value Configured to destination: System interface 3I0 (zero sequence) of side 2 Type: MV - Measured value I1 (positive sequence) of side 2 Type: MV - Measured value I2 (negative sequence) of side 2 Type: MV - Measured value Operat. meas. current IL1 side 3 Type: MV - Measured value Operat. meas. current IL2 side 3 Type: MV - Measured value Operat. meas. current IL3 side 3 Type: MV - Measured value 3I0 (zero sequence) of side 3 Type: MV - Measured value I1 (positive sequence) of side 3 Type: MV - Measured value I2 (negative sequence) of side 3 Type: MV - Measured value Operat. meas. auxiliary current IX1 Type: MV - Measured value Phase angle in phase IL1 meas. loc. 1 Type: MV - Measured value Phase angle in phase IL2 meas. loc. 1 Type: MV - Measured value Phase angle in phase IL3 meas. loc. 1 Type: MV - Measured value Phase angle in phase IL1 meas. loc. 2 Type: MV - Measured value Phase angle in phase IL2 meas. loc. 2 Type: MV - Measured value Phase angle in phase IL3 meas. loc. 2 Type: MV - Measured value Phase angle in phase IL1 meas. loc. 3 Type: MV - Measured value Phase angle in phase IL2 meas. loc. 3 Type: MV - Measured value Phase angle in phase IL3 meas. loc. 3 Type: MV - Measured value Phase angle in auxiliary current IX1 Type: MV - Measured value Operat. meas. voltage Umeas. Type: MVU - User-defined measured value Configured to source: CFC Configured to destination: Measured value window Operation. pri S (apparent power) Type: MV - Measured value Frequency Type: MV - Measured value 2.3.2 Diff- and Rest. Measurement IDiffL1(I/Inominal object [%]) Type: MV - Measured value IDiffL2(I/Inominal object [%]) Type: MV - Measured value IDiffL3(I/Inominal object [%]) Type: MV - Measured value IRestL1(I/Inominal object [%]) Type: MV - Measured value IRestL2(I/Inominal object [%]) Type: MV - Measured value IRestL3(I/Inominal object [%]) Type: MV - Measured value Idiff REF (I/Inominal object [%]) Type: MV - Measured value Irest REF (I/Inominal object [%]) Type: MV - Measured value 2.4 Metered values 2.4.1 Energy Pulsed Energy Wp (active) Type: PMV - Pulse metered value Configured to destination: System interface Metered value window Pulsed Energy Wq (reactive) Type: PMV - Pulse metered value Configured to destination: System interface Metered value window 2.5 Display after fault+-----------------+------------------------------------------------------+| Line | Type |+-----------------+------------------------------------------------------+| 1. Display line | Protective function that picked up |+-----------------+------------------------------------------------------+| 2. Display line | Protective function that tripped |+-----------------+------------------------------------------------------+| 3. Display line | Elapsed time from begin of pickup until drop-out |+-----------------+------------------------------------------------------+| 4. Display line | Elapsed time from begin of pickup until trip command |+-----------------+------------------------------------------------------+| 5. Display line | No alarm |+-----------------+------------------------------------------------------+| 6. Display line | No alarm |+-----------------+------------------------------------------------------+3 Configuration - short (column-oriented) 3.1 Binary inputs+---------------+-----+-----------------+-------------+------+---------------+| Binary inputs | No. | Group | Information | Type | Configuration |+---------------+-----+-----------------+-------------+------+---------------+| 1 | | Ext. Tansf.Ann. | Pres_Trip | SP | H |+---------------+-----+-----------------+-------------+------+---------------+| 2 | | Ext. Tansf.Ann. | Wind_Temp | SP | H |+---------------+-----+-----------------+-------------+------+---------------+| 3 | | Ext. Tansf.Ann. | Oil Win_Te | SP | H |+---------------+-----+-----------------+-------------+------+---------------+ 3.2 Binary outputs+----+-------------+-----------------+------------------------------+------+---------------+| BO | No. | Group | Information | Type | Configuration |+----+-------------+-----------------+------------------------------+------+---------------+| 1 | 05671 | Diff. Prot | Differential protection TRIP | OUT | U |+----+-------------+-----------------+------------------------------+------+---------------+| 2 | 199.2451.01 | REF | Restr. earth flt.: TRIP | OUT | U |+----+-------------+-----------------+------------------------------+------+---------------+| 3 | 024.2552.01 | Earth O/C | IE> TRIP | OUT | U |+----+-------------+-----------------+------------------------------+------+---------------+| 4 | 023.2551.01 | Phase O/C | I>> TRIP | OUT | U |+----+-------------+-----------------+------------------------------+------+---------------+| 4 | 023.2552.01 | Phase O/C | I> TRIP | OUT | U |+----+-------------+-----------------+------------------------------+------+---------------+| 4 | 023.2553.01 | Phase O/C | Ip TRIP | OUT | U |+----+-------------+-----------------+------------------------------+------+---------------+| 5 | | Ext. Tansf.Ann. | Pres_Trip | SP | U |+----+-------------+-----------------+------------------------------+------+---------------+| 5 | | Ext. Tansf.Ann. | Wind_Temp | SP | U |+----+-------------+-----------------+------------------------------+------+---------------+| 5 | | Ext. Tansf.Ann. | Oil Win_Te | SP | U |+----+-------------+-----------------+------------------------------+------+---------------+| 6 | 05671 | Diff. Prot | Differential protection TRIP | OUT | U |+----+-------------+-----------------+------------------------------+------+---------------+| 7 | 05671 | Diff. Prot | Differential protection TRIP | OUT | U |+----+-------------+-----------------+------------------------------+------+---------------+| 7 | 199.2451.01 | REF | Restr. earth flt.: TRIP | OUT | U |+----+-------------+-----------------+------------------------------+------+---------------+| 8 | 023.2551.01 | Phase O/C | I>> TRIP | OUT | U |+----+-------------+-----------------+------------------------------+------+---------------+| 8 | 023.2552.01 | Phase O/C | I> TRIP | OUT | U |+----+-------------+-----------------+------------------------------+------+---------------+| 8 | 023.2553.01 | Phase O/C | Ip TRIP | OUT | U |+----+-------------+-----------------+------------------------------+------+---------------+ 3.3 LEDs+------+-------------+-----------------+------------------------------+------+---------------+| LEDs | No. | Group | Information | Type | Configuration |+------+-------------+-----------------+------------------------------+------+---------------+| 1 | 00501 | P.System Data 2 | Relay PICKUP | OUT | L |+------+-------------+-----------------+------------------------------+------+---------------+| 2 | 05671 | Diff. Prot | Differential protection TRIP | OUT | L |+------+-------------+-----------------+------------------------------+------+---------------+| 3 | 199.2451.01 | REF | Restr. earth flt.: TRIP | OUT | L |+------+-------------+-----------------+------------------------------+------+---------------+| 4 | 023.2551.01 | Phase O/C | I>> TRIP | OUT | L |+------+-------------+-----------------+------------------------------+------+---------------+| 4 | 023.2552.01 | Phase O/C | I> TRIP | OUT | L |+------+-------------+-----------------+------------------------------+------+---------------+| 4 | 023.2553.01 | Phase O/C | Ip TRIP | OUT | L |+------+-------------+-----------------+------------------------------+------+---------------+| 4 | | Phase O/C | 50/51 | OUT | L |+------+-------------+-----------------+------------------------------+------+---------------+| 5 | 024.2552.01 | Earth O/C | IE> TRIP | OUT | L |+------+-------------+-----------------+------------------------------+------+---------------+| 6 | | Ext. Tansf.Ann. | Pres_Trip | SP | L |+------+-------------+-----------------+------------------------------+------+---------------+| 7 | | Ext. Tansf.Ann. | Wind_Temp | SP | L |+------+-------------+-----------------+------------------------------+------+---------------+| 8 | | Ext. Tansf.Ann. | Oil Win_Te | SP | L |+------+-------------+-----------------+------------------------------+------+---------------+ 3.4 CFC+-------------+-----------------+---------------------------------------------+--------+-------------+| No. | Group | Information | Source | Destination |+-------------+-----------------+---------------------------------------------+--------+-------------+| | Device | UnlockDT / Unlock data transmission via BI | X | |+-------------+-----------------+---------------------------------------------+--------+-------------+| 00004 | Osc. Fault Rec. | >Trig.Wave.Cap. / >Trigger Waveform Capture | X | |+-------------+-----------------+---------------------------------------------+--------+-------------+| 023.2551.01 | Phase O/C | I>> TRIP / I>> TRIP | | X |+-------------+-----------------+---------------------------------------------+--------+-------------+| 023.2552.01 | Phase O/C | I> TRIP / I> TRIP | | X |+-------------+-----------------+---------------------------------------------+--------+-------------+| 023.2553.01 | Phase O/C | Ip TRIP / Ip TRIP | | X |+-------------+-----------------+---------------------------------------------+--------+-------------+| | Phase O/C | 50/51 / 50/51 | X | |+-------------+-----------------+---------------------------------------------+--------+-------------+| | Ext. Tansf.Ann. | Pres_Trip / Pres_Trip | | X |+-------------+-----------------+---------------------------------------------+--------+-------------+| | Ext. Tansf.Ann. | Wind_Temp / Wind_Temp | | X |+-------------+-----------------+---------------------------------------------+--------+-------------+| | Ext. Tansf.Ann. | Oil Win_Te / Oil Win_Te | | X |+-------------+-----------------+---------------------------------------------+--------+-------------+| 30656 | Measurement | Umeas.= / Operat. meas. voltage Umeas. | X | |+-------------+-----------------+---------------------------------------------+--------+-------------+ 3.5 Function keys nothing allocated 3.6 Buffer 3.6.1 Operational indication buffer+-------------+-----------------+------------------------------------------+--------+| No. | Group | Information | Buffer |+-------------+-----------------+------------------------------------------+--------+| | Device | Reset LED | I |+-------------+-----------------+------------------------------------------+--------+| | Device | Test mode | IO |+-------------+-----------------+------------------------------------------+--------+| | Device | Stop data transmission | IO |+-------------+-----------------+------------------------------------------+--------+| | Device | >Back Light on | IO |+-------------+-----------------+------------------------------------------+--------+| 00051 | Device | Device is Operational and Protecting | IO |+-------------+-----------------+------------------------------------------+--------+| 00052 | Device | At Least 1 Protection Funct. is Active | IO |+-------------+-----------------+------------------------------------------+--------+| 00056 | Device | Initial Start of Device | I |+-------------+-----------------+------------------------------------------+--------+| 00067 | Device | Resume | I |+-------------+-----------------+------------------------------------------+--------+| 00069 | Device | Daylight Saving Time | IO |+-------------+-----------------+------------------------------------------+--------+| 00070 | Device | Setting calculation is running | IO |+-------------+-----------------+------------------------------------------+--------+| 00072 | Device | Level-2 change | IO |+-------------+-----------------+------------------------------------------+--------+| 00109 | Device | Frequency out of range | IO |+-------------+-----------------+------------------------------------------+--------+| 00125 | Device | Chatter ON | IO |+-------------+-----------------+------------------------------------------+--------+| | Device | Hardware Test Mode | IO |+-------------+-----------------+------------------------------------------+--------+| 00320 | Device | Warn: Limit of Memory Data exceeded | IO |+-------------+-----------------+------------------------------------------+--------+| 00321 | Device | Warn: Limit of Memory Parameter exceeded | IO |+-------------+-----------------+------------------------------------------+--------+| 00322 | Device | Warn: Limit of Memory Operation exceeded | IO |+-------------+-----------------+------------------------------------------+--------+| 00323 | Device | Warn: Limit of Memory New exceeded | IO |+-------------+-----------------+------------------------------------------+--------+| 05145 | P.System Data 1 | >Reverse Phase Rotation | IO |+-------------+-----------------+------------------------------------------+--------+| 05147 | P.System Data 1 | Phase Rotation L1L2L3 | IO |+-------------+-----------------+------------------------------------------+--------+| 05148 | P.System Data 1 | Phase Rotation L1L3L2 | IO |+-------------+-----------------+------------------------------------------+--------+| | Osc. Fault Rec. | Fault Recording Start | IO |+-------------+-----------------+------------------------------------------+--------+| 00311 | P.System Data 2 | Fault in configuration / setting | IO |+-------------+-----------------+------------------------------------------+--------+| 00312 | P.System Data 2 | Gen.err.: Inconsistency group/connection | I |+-------------+-----------------+------------------------------------------+--------+| 00313 | P.System Data 2 | Gen.err.: Sev. earth-CTs with equal typ | I |+-------------+-----------------+------------------------------------------+--------+| 00314 | P.System Data 2 | Gen.err.: Number of sides / measurements | I |+-------------+-----------------+------------------------------------------+--------+| 30060 | P.System Data 2 | General: Adaption factor CT M1 | IO |+-------------+-----------------+------------------------------------------+--------+| 30061 | P.System Data 2 | General: Adaption factor CT M2 | IO |+-------------+-----------------+------------------------------------------+--------+| 30062 | P.System Data 2 | General: Adaption factor CT M3 | IO |+-------------+-----------------+------------------------------------------+--------+| 30067 | P.System Data 2 | parameter too low: | IO |+-------------+-----------------+------------------------------------------+--------+| 30068 | P.System Data 2 | parameter too high: | IO |+-------------+-----------------+------------------------------------------+--------+| 30069 | P.System Data 2 | setting fault: | IO |+-------------+-----------------+------------------------------------------+--------+| 30070 | P.System Data 2 | Manual close signal meas.loc. 1 detected | I |+-------------+-----------------+------------------------------------------+--------+| 30071 | P.System Data 2 | Manual close signal meas.loc. 2 detected | I |+-------------+-----------------+------------------------------------------+--------+| 30072 | P.System Data 2 | Manual close signal meas.loc. 3 detected | I |+-------------+-----------------+------------------------------------------+--------+| 30075 | P.System Data 2 | Manual close signal side 1 is detected | I |+-------------+-----------------+------------------------------------------+--------+| 30076 | P.System Data 2 | Manual close signal side 2 is detected | I |+-------------+-----------------+------------------------------------------+--------+| 30077 | P.System Data 2 | Manual close signal side 3 is detected | I |+-------------+-----------------+------------------------------------------+--------+| 00126 | P.System Data 2 | Protection ON/OFF (via system port) | IO |+-------------+-----------------+------------------------------------------+--------+| 05615 | Diff. Prot | Differential protection is switched OFF | IO |+-------------+-----------------+------------------------------------------+--------+| 05616 | Diff. Prot | Differential protection is BLOCKED | IO |+-------------+-----------------+------------------------------------------+--------+| 05617 | Diff. Prot | Differential protection is ACTIVE | IO |+-------------+-----------------+------------------------------------------+--------+| 05620 | Diff. Prot | Diff err.: adverse Adaption factor CT | I |+-------------+-----------------+------------------------------------------+--------+| 05733 | Diff. Prot | Diff. prot: Adaption factor CT M1 | IO |+-------------+-----------------+------------------------------------------+--------+| 05734 | Diff. Prot | Diff. prot: Adaption factor CT M2 | IO |+-------------+-----------------+------------------------------------------+--------+| 05735 | Diff. Prot | Diff. prot: Adaption factor CT M3 | IO |+-------------+-----------------+------------------------------------------+--------+| 05738 | Diff. Prot | Diff. prot: Adaption factor aux. CT IX1 | IO |+-------------+-----------------+------------------------------------------+--------+| 05666 | Diff. Prot | Diff: Increase of char. phase (start) L1 | IO |+-------------+-----------------+------------------------------------------+--------+| 05667 | Diff. Prot | Diff: Increase of char. phase (start) L2 | IO |+-------------+-----------------+------------------------------------------+--------+| 05668 | Diff. Prot | Diff: Increase of char. phase (start) L3 | IO |+-------------+-----------------+------------------------------------------+--------+| 199.2411.01 | REF | Restricted earth fault is switched OFF | IO |+-------------+-----------------+------------------------------------------+--------+| 199.2412.01 | REF | Restricted earth fault is BLOCKED | IO |+-------------+-----------------+------------------------------------------+--------+| 199.2413.01 | REF | Restricted earth fault is ACTIVE | IO |+-------------+-----------------+------------------------------------------+--------+| 199.2639.01 | REF | REF: Adaption factor CT starpnt. wind. | IO |+-------------+-----------------+------------------------------------------+--------+| 199.2494.01 | REF | REF err.: adverse Adaption factor CT | I |+-------------+-----------------+------------------------------------------+--------+| 199.2492.01 | REF | REF err.: No starpoint CT | I |+-------------+-----------------+------------------------------------------+--------+| 199.2491.01 | REF | REF err.: Not available for this object | I |+-------------+-----------------+------------------------------------------+--------+| 023.2501.01 | Phase O/C | >BLOCK time overcurrent Phase InRush | IO |+-------------+-----------------+------------------------------------------+--------+| 023.2411.01 | Phase O/C | Time Overcurrent Phase is OFF | IO |+-------------+-----------------+------------------------------------------+--------+| 023.2412.01 | Phase O/C | Time Overcurrent Phase is BLOCKED | IO |+-------------+-----------------+------------------------------------------+--------+| 023.2413.01 | Phase O/C | Time Overcurrent Phase is ACTIVE | IO |+-------------+-----------------+------------------------------------------+--------+| 023.2514.01 | Phase O/C | I>> BLOCKED | IO |+-------------+-----------------+------------------------------------------+--------+| 023.2515.01 | Phase O/C | I> BLOCKED | IO |+-------------+-----------------+------------------------------------------+--------+| 023.2516.01 | Phase O/C | Ip BLOCKED | IO |+-------------+-----------------+------------------------------------------+--------+| 023.2491.01 | Phase O/C | O/C Phase: Not available for this object | I |+-------------+-----------------+------------------------------------------+--------+| | Phase O/C | 50/51 | IO |+-------------+-----------------+------------------------------------------+--------+| 024.2501.01 | Earth O/C | >BLOCK time overcurrent Earth InRush | IO |+-------------+-----------------+------------------------------------------+--------+| 024.2411.01 | Earth O/C | Time Overcurrent Earth is OFF | IO |+-------------+-----------------+------------------------------------------+--------+| 024.2412.01 | Earth O/C | Time Overcurrent Earth is BLOCKED | IO |+-------------+-----------------+------------------------------------------+--------+| 024.2413.01 | Earth O/C | Time Overcurrent Earth is ACTIVE | IO |+-------------+-----------------+------------------------------------------+--------+| 024.2514.01 | Earth O/C | IE>> BLOCKED | IO |+-------------+-----------------+------------------------------------------+--------+| 024.2515.01 | Earth O/C | IE> BLOCKED | IO |+-------------+-----------------+------------------------------------------+--------+| 024.2492.01 | Earth O/C | O/C Earth err.: No auxiliary CT assigned | I |+-------------+-----------------+------------------------------------------+--------+| 30361 | Discon.MeasLoc | >disconnect without test: current = 0 | IO |+-------------+-----------------+------------------------------------------+--------+| 30362 | Discon.MeasLoc | >disconnect measurment location 1 | IO |+-------------+-----------------+------------------------------------------+--------+| 30080 | Discon.MeasLoc | Measurment location 1 is disconnected | IO |+-------------+-----------------+------------------------------------------+--------+| 30363 | Discon.MeasLoc | >disconnect measurment location 2 | IO |+-------------+-----------------+------------------------------------------+--------+| 30081 | Discon.MeasLoc | Measurment location 2 is disconnected | IO |+-------------+-----------------+------------------------------------------+--------+| 30364 | Discon.MeasLoc | >disconnect measurment location 3 | IO |+-------------+-----------------+------------------------------------------+--------+| 30082 | Discon.MeasLoc | Measurment location 3 is disconnected | IO |+-------------+-----------------+------------------------------------------+--------+| 00161 | Measurem.Superv | Failure: General Current Supervision | IO |+-------------+-----------------+------------------------------------------+--------+| 00163 | Measurem.Superv | Failure: Current Balance | IO |+-------------+-----------------+------------------------------------------+--------+| 30110 | Measurem.Superv | Fail.: Current Balance meas. location 1 | IO |+-------------+-----------------+------------------------------------------+--------+| 30111 | Measurem.Superv | Fail.: Current Balance meas. location 2 | IO |+-------------+-----------------+------------------------------------------+--------+| 30112 | Measurem.Superv | Fail.: Current Balance meas. location 3 | IO |+-------------+-----------------+------------------------------------------+--------+| 00171 | Measurem.Superv | Failure: Phase Sequence | IO |+-------------+-----------------+------------------------------------------+--------+| 00175 | Measurem.Superv | Failure: Phase Sequence Current | IO |+-------------+-----------------+------------------------------------------+--------+| 30115 | Measurem.Superv | Failure: Phase Sequence I meas. loc. 1 | IO |+-------------+-----------------+------------------------------------------+--------+| 30116 | Measurem.Superv | Failure: Phase Sequence I meas. loc. 2 | IO |+-------------+-----------------+------------------------------------------+--------+| 30117 | Measurem.Superv | Failure: Phase Sequence I meas. loc. 3 | IO |+-------------+-----------------+------------------------------------------+--------+| | Supervision | Disturbance CFC | IO |+-------------+-----------------+------------------------------------------+--------+| 00110 | Supervision | Event lost | I |+-------------+-----------------+------------------------------------------+--------+| 00113 | Supervision | Flag Lost | I |+-------------+-----------------+------------------------------------------+--------+| 00181 | Supervision | Error: Measurement system | IO |+-------------+-----------------+------------------------------------------+--------+| 00190 | Supervision | Error Board 0 | IO |+-------------+-----------------+------------------------------------------+--------+| 00183 | Supervision | Error Board 1 | IO |+-------------+-----------------+------------------------------------------+--------+| 00184 | Supervision | Error Board 2 | IO |+-------------+-----------------+------------------------------------------+--------+| 00185 | Supervision | Error Board 3 | IO |+-------------+-----------------+------------------------------------------+--------+| 00186 | Supervision | Error Board 4 | IO |+-------------+-----------------+------------------------------------------+--------+| 00187 | Supervision | Error Board 5 | IO |+-------------+-----------------+------------------------------------------+--------+| 00188 | Supervision | Error Board 6 | IO |+-------------+-----------------+------------------------------------------+--------+| 00189 | Supervision | Error Board 7 | IO |+-------------+-----------------+------------------------------------------+--------+| 00192 | Supervision | Error:1A/5Ajumper different from setting | IO |+-------------+-----------------+------------------------------------------+--------+| 30097 | Supervision | Err: inconsist. jumper/setting CT M1 | IO |+-------------+-----------------+------------------------------------------+--------+| 30098 | Supervision | Err: inconsist. jumper/setting CT M2 | IO |+-------------+-----------------+------------------------------------------+--------+| 30099 | Supervision | Err: inconsist. jumper/setting CT M3 | IO |+-------------+-----------------+------------------------------------------+--------+| 30106 | Supervision | Err: inconsist. jumper/setting CT IX1 | IO |+-------------+-----------------+------------------------------------------+--------+| 00191 | Supervision | Error: Offset | IO |+-------------+-----------------+------------------------------------------+--------+| 30145 | Supervision | Failure: disconnect measurment location | IO |+-------------+-----------------+------------------------------------------+--------+| 30054 | Supervision | Broken wire is switched OFF | IO |+-------------+-----------------+------------------------------------------+--------+| 00251 | Supervision | Broken wire detected | IO |+-------------+-----------------+------------------------------------------+--------+| 30120 | Supervision | Broken wire IL1 measurement location 1 | IO |+-------------+-----------------+------------------------------------------+--------+| 30121 | Supervision | Broken wire IL2 measurement location 1 | IO |+-------------+-----------------+------------------------------------------+--------+| 30122 | Supervision | Broken wire IL3 measurement location 1 | IO |+-------------+-----------------+------------------------------------------+--------+| 30123 | Supervision | Broken wire IL1 measurement location 2 | IO |+-------------+-----------------+------------------------------------------+--------+| 30124 | Supervision | Broken wire IL2 measurement location 2 | IO |+-------------+-----------------+------------------------------------------+--------+| 30125 | Supervision | Broken wire IL3 measurement location 2 | IO |+-------------+-----------------+------------------------------------------+--------+| 30126 | Supervision | Broken wire IL1 measurement location 3 | IO |+-------------+-----------------+------------------------------------------+--------+| 30127 | Supervision | Broken wire IL2 measurement location 3 | IO |+-------------+-----------------+------------------------------------------+--------+| 30128 | Supervision | Broken wire IL3 measurement location 3 | IO |+-------------+-----------------+------------------------------------------+--------+| 00193 | Supervision | Alarm: Analog input adjustment invalid | IO |+-------------+-----------------+------------------------------------------+--------+| 00177 | Supervision | Failure: Battery empty | IO |+-------------+-----------------+------------------------------------------+--------+| 00068 | Supervision | Clock Synchronization Error | IO |+-------------+-----------------+------------------------------------------+--------+| 00198 | Supervision | Error: Communication Module B | IO |+-------------+-----------------+------------------------------------------+--------+| 00199 | Supervision | Error: Communication Module C | IO |+-------------+-----------------+------------------------------------------+--------+| 00200 | Supervision | Error: Communication Module D | IO |+-------------+-----------------+------------------------------------------+--------+| 30135 | Supervision | Incons. M1: CBaux open/ curr. persistent | IO |+-------------+-----------------+------------------------------------------+--------+| 30136 | Supervision | Incons. M2: CBaux open/ curr. persistent | IO |+-------------+-----------------+------------------------------------------+--------+| 30137 | Supervision | Incons. M3: CBaux open/ curr. persistent | IO |+-------------+-----------------+------------------------------------------+--------+| 30140 | Supervision | Incons. S1: CBaux open/ curr. persistent | IO |+-------------+-----------------+------------------------------------------+--------+| 30141 | Supervision | Incons. S2: CBaux open/ curr. persistent | IO |+-------------+-----------------+------------------------------------------+--------+| 30142 | Supervision | Incons. S3: CBaux open/ curr. persistent | IO |+-------------+-----------------+------------------------------------------+--------+| 00390 | Ext. Tansf.Ann. | >Warning stage from gas in oil detector | IO |+-------------+-----------------+------------------------------------------+--------+| 00391 | Ext. Tansf.Ann. | >Warning stage from Buchholz protection | IO |+-------------+-----------------+------------------------------------------+--------+| 00392 | Ext. Tansf.Ann. | >Tripp. stage from Buchholz protection | IO |+-------------+-----------------+------------------------------------------+--------+| 00393 | Ext. Tansf.Ann. | >Tank supervision from Buchh. protect. | IO |+-------------+-----------------+------------------------------------------+--------+| | Ext. Tansf.Ann. | Pres_Trip | IO |+-------------+-----------------+------------------------------------------+--------+| | Ext. Tansf.Ann. | Wind_Temp | IO |+-------------+-----------------+------------------------------------------+--------+| | Ext. Tansf.Ann. | Oil Win_Te | IO |+-------------+-----------------+------------------------------------------+--------+| | Cntrl Authority | Control Authority | IO |+-------------+-----------------+------------------------------------------+--------+| | Cntrl Authority | Controlmode REMOTE | IO |+-------------+-----------------+------------------------------------------+--------+| | Cntrl Authority | Controlmode LOCAL | IO |+-------------+-----------------+------------------------------------------+--------+| | Thresh.-Switch | Threshold Value 1 | IO |+-------------+-----------------+------------------------------------------+--------+| 00409 | Statistics | >BLOCK Op Counter | IO |+-------------+-----------------+------------------------------------------+--------+| 00272 | SetPoint(Stat) | Set Point Operating Hours | IO |+-------------+-----------------+------------------------------------------+--------+3.6.2 Sensitive ground fault indication buffer nothing allocated 3.6.3 Trip log+-------------+-----------------+------------------------------------------+--------+| No. | Group | Information | Buffer |+-------------+-----------------+------------------------------------------+--------+| 00501 | P.System Data 2 | Relay PICKUP | I |+-------------+-----------------+------------------------------------------+--------+| 00511 | P.System Data 2 | Relay GENERAL TRIP command | I |+-------------+-----------------+------------------------------------------+--------+| 05616 | Diff. Prot | Differential protection is BLOCKED | IO |+-------------+-----------------+------------------------------------------+--------+| 05631 | Diff. Prot | Differential protection picked up | IO |+-------------+-----------------+------------------------------------------+--------+| 05644 | Diff. Prot | Diff: Blocked by 2.Harmon. L1 | IO |+-------------+-----------------+------------------------------------------+--------+| 05645 | Diff. Prot | Diff: Blocked by 2.Harmon. L2 | IO |+-------------+-----------------+------------------------------------------+--------+| 05646 | Diff. Prot | Diff: Blocked by 2.Harmon. L3 | IO |+-------------+-----------------+------------------------------------------+--------+| 05647 | Diff. Prot | Diff: Blocked by n.Harmon. L1 | IO |+-------------+-----------------+------------------------------------------+--------+| 05648 | Diff. Prot | Diff: Blocked by n.Harmon. L2 | IO |+-------------+-----------------+------------------------------------------+--------+| 05649 | Diff. Prot | Diff: Blocked by n.Harmon. L3 | IO |+-------------+-----------------+------------------------------------------+--------+| 05651 | Diff. Prot | Diff. prot.: Blocked by ext. fault L1 | IO |+-------------+-----------------+------------------------------------------+--------+| 05652 | Diff. Prot | Diff. prot.: Blocked by ext. fault L2 | IO |+-------------+-----------------+------------------------------------------+--------+| 05653 | Diff. Prot | Diff. prot.: Blocked by ext. fault.L3 | IO |+-------------+-----------------+------------------------------------------+--------+| 05657 | Diff. Prot | Diff: Crossblock by 2.Harmonic | IO |+-------------+-----------------+------------------------------------------+--------+| 05658 | Diff. Prot | Diff: Crossblock by n.Harmonic | IO |+-------------+-----------------+------------------------------------------+--------+| 05660 | Diff. Prot | Diff: Crossblock by ext. fault | IO |+-------------+-----------------+------------------------------------------+--------+| 05666 | Diff. Prot | Diff: Increase of char. phase (start) L1 | IO |+-------------+-----------------+------------------------------------------+--------+| 05667 | Diff. Prot | Diff: Increase of char. phase (start) L2 | IO |+-------------+-----------------+------------------------------------------+--------+| 05668 | Diff. Prot | Diff: Increase of char. phase (start) L3 | IO |+-------------+-----------------+------------------------------------------+--------+| 05742 | Diff. Prot | Diff: DC L1 | IO |+-------------+-----------------+------------------------------------------+--------+| 05743 | Diff. Prot | Diff: DC L2 | IO |+-------------+-----------------+------------------------------------------+--------+| 05744 | Diff. Prot | Diff: DC L3 | IO |+-------------+-----------------+------------------------------------------+--------+| 05745 | Diff. Prot | Diff: Increase of char. phase (DC) | IO |+-------------+-----------------+------------------------------------------+--------+| 05681 | Diff. Prot | Diff. prot.: IDIFF> L1 (without Tdelay) | IO |+-------------+-----------------+------------------------------------------+--------+| 05682 | Diff. Prot | Diff. prot.: IDIFF> L2 (without Tdelay) | IO |+-------------+-----------------+------------------------------------------+--------+| 05683 | Diff. Prot | Diff. prot.: IDIFF> L3 (without Tdelay) | IO |+-------------+-----------------+------------------------------------------+--------+| 05684 | Diff. Prot | Diff. prot: IDIFF>> L1 (without Tdelay) | IO |+-------------+-----------------+------------------------------------------+--------+| 05685 | Diff. Prot | Diff. prot: IDIFF>> L2 (without Tdelay) | IO |+-------------+-----------------+------------------------------------------+--------+| 05686 | Diff. Prot | Diff. prot: IDIFF>> L3 (without Tdelay) | IO |+-------------+-----------------+------------------------------------------+--------+| 05691 | Diff. Prot | Differential prot.: TRIP by IDIFF> | I |+-------------+-----------------+------------------------------------------+--------+| 05692 | Diff. Prot | Differential prot.: TRIP by IDIFF>> | I |+-------------+-----------------+------------------------------------------+--------+| 05701 | Diff. Prot | Diff. curr. in L1 at trip without Tdelay | IO |+-------------+-----------------+------------------------------------------+--------+| 05702 | Diff. Prot | Diff. curr. in L2 at trip without Tdelay | IO |+-------------+-----------------+------------------------------------------+--------+| 05703 | Diff. Prot | Diff. curr. in L3 at trip without Tdelay | IO |+-------------+-----------------+------------------------------------------+--------+| 05704 | Diff. Prot | Restr.curr. in L1 at trip without Tdelay | IO |+-------------+-----------------+------------------------------------------+--------+| 05705 | Diff. Prot | Restr.curr. in L2 at trip without Tdelay | IO |+-------------+-----------------+------------------------------------------+--------+| 05706 | Diff. Prot | Restr.curr. in L3 at trip without Tdelay | IO |+-------------+-----------------+------------------------------------------+--------+| 199.2412.01 | REF | Restricted earth fault is BLOCKED | IO |+-------------+-----------------+