Antistatic Unit
eFLOW Antistatic Unit 112
KITZ-SCT's wet systems that meet users' needs
e F LOW
KITZ-SCT designs and produces all types of wet
equipment to meet users' needs.
We offer high-reliability equipment because of our
original technology, special-purpose clean room, and
inspection facilities, among other things.
112
PanelMountType(PSeries) CabinetType(CSeries)
ThePSeriescanbeinstalledonarackinaccordancewiththeEIA(ElectronicIndustriesAlliance)standard.The1APmodelusesmetal-freeparts forallwettedareas.The2APmodelcanbemetal-freeforallwettedareasasanoption.
TheCSerieshasacabinetwithacapacityfortwoCO2cylinders.Thereisabuilt-inspecificresistancesensorinthecabinet,enablingconnec-tiontowaterpipestothepointofusedirectlyfromeFLOW.
The eFLOW® Series is an apparatus to control the resistivity of the DI water by supplying the CO2 through a "hollow fiber gas permeable membrane" developed by DIC Corp.
Features Alowfailurerateachievedduetomechanismwithoutcomplicatedcontrol. Auniquepipinglayoutprovidesstableresistivityvalueandenableseasycontroloftheresistivity. LonglifeoftheCO2aerationmodule(Guaranteedforfiveyears,madebyKITZSCT)
Effects Preventsredepositionofcontaminantsduetostaticelectricity Preventselectrostaticdestructionofsubstratepattern
Effectivefield/use
eFLOWAntistaticUnit
Field Use
LSILCD
photomask/reticle cleaning
Scrubber cleaning
High-pressure jet cleaning
Cleaning in the dicing process
Cell cleaning
432
480
700
464
350
216
360
1190
220
900
432
480
700
464
350
216
360
1190
220
900
UltraH
ighPurityValvesUltraH
ighPurityFittingsVacuum
Com
ponentsPFAValves
PFAWeldFittings
AntistaticUnit
113
DevicePrinciples
ThespecificresistancevalueofDIwatercanbeadjustedbyregulatingthemixingratioofCO2saturatedwaterandultraDIwatergeneratedbytheCO2dissolutionmodule(seethepicturebelow).
CO2DissolutionPrinciples
WhileDIwaterflowsthroughtheinsidethehollowfibersinthemodule,CO2gaspenetratestheDIwaterfromoutsidethehollowfibermembrane.ThedissolvedCO2ionizesinDIwater,providingconductivitytoDIwatertoremovestaticelec-tricity.Usingthefinehollowfiberbundle,thesurfacearearequiredfortheCO2dissolu-tioncanbeobtainedefficiently.
CO2DissolutionModule(InternalCirculation)MadebyDIC
H2O+CO2→H2CO3
H2CO3→H++HCO3-
HCO3-→H++CO3
2-
Resistivity Sensor
DIW IN Resistivity control nob
Resistivity MeterPower Switch
Manual purge Switch
Auto-purgetimer
Gas filter CO2gas
CO2 gas Injetion module
CO2 gas purge valve
CO2 slow-leak(Capillary)
CO2 gasregulator
0.2MPa>CO2 gasshut valve
CO2 gas
Drain
Treated Water
Arrange piping length ofno less than 2m.Arrange piping length ofno less than 2m.
18.2MΩ・cm
18.2
MΩ・
cm
0.2~1.0MΩ・cm
≒0.02MΩ・cm
H2O+CO2
CO2IN
DIW
CO2gas
Hollow fiber
BehaviorofResistivityValueDuringFlowRateFluctuation
*Theresistivityperformanceduringflowratefluctuationisnotguaranteed.*Thegraphsprovidedareforreferenceonly.Theperformanceandcharacteristicsmayvarywithoperatingconditions.
ExampleofScrubberCleaningScrubbercleaningsample
4L/min(0.5min)←→8L/min(0.5min)
ExampleofDicingDicingprocesssample
OL/min(5min)←→8L/min(5min)
TheeFLOW2Aand3Amodelsareequippedwithtwocarbondioxidedissolutionmodules.
(eFLOW 2AP,2AC eFLOW 3AP,3AC) (eFLOW 1AP,1AC)
114
Unit:eFLOW® Panelmounttype CabinettypeType 1AP-B02 2AP-B01 3AP-B01 1AC-P101 2AC-P101 3AC-P101
RangeofTreatedWaterFlowRate[L/min] 1~16 5~30 10~50 1~16 5~30 10~50
ConnectionSize φ12mm Rc1"PP Rc3/4" PVC union Rc1" PVC union
Module 1 PF-001L-NA (1 module)
2 PF-001L-ND2s (2 modules)
2 PF-001L-ND3s (3 modules)
1 PF-001L-NA (1 module)
2 PF-001L-ND2s (2 modules)
2 PF-001L-ND3s (3 modules)
RangeofResistivitySettings 0.2~1.0 (MΩ) *(1)
StabilityDuringConstantFlowRate Within ± 15% (stability during flow rate fluctuation not guaranteed)
OperatingFluid Supply water: RO water or better, supply gas: CO2 gas (99.5% or higher purity) Dry air or N2 gas for drying * No other fluids may be used.
SupplyWaterTemperatureandPressureRange 20~30 (ºC) 0.1~0.3 (MPa) Max. 0.5 (MPa)
CO2GasSupply Supplied from the utility on the user sideCan be outfitted with two CO2 gas tanks (optional)
φ140 (5 kg capacity) or φ175 (7 kg capacity)
CO2GasSupplyPressure Less than 0.2 MPa (Outlet pressure of the CO2 tank for cabinet type)
RangeofCO2GasSettings 0.05~0.15 MPa (the pressure set on the eFLOW front panel)
OperatingEnvironmentandStorageTemperature 20~30 (°C) 10~40 (°C) (cannot be frozen)
PowerSupplySpecificationsandPowerConsumption Single-phase AC 100-240V 50/60 Hz Maximum 100VA
Warning Upper and lower limits of resistivity value, power supply monitor:Warning lamp, buzzer (with reset switch)
Upper and lower limits of resistivity value, power supply monitor, water leak detection:
Warning lamp, buzzer (with reset switch)
ExternalOutput Warning: relay contact (c contact) capacity AC 220V DC 24V 3 A (load resistance)Transmitted output: 4~20 mA maximum load resistance 900 Ω insulated output
ExternalDimensionsW432×D350×H199.5[mm] (BOX part)
W480×H216×t3[mm] (panel part)Does not include protuberance
W700×D360×H1120[mm] (BOX part)W700×H900[mm] (opening part)Does not include protuberance
Material Hair-lined SS panel SS Baked-on panint finish
Weight About 9 kg About 100 kg
FasteningMethods Can be attached to EIA-standard rack L-angle caster (with adjuster)
ResistivityMeter HE480-R (AC) (AC100~240V) Manufactured by HORIBA Advanced Techno Co., Ltd.
ResistivitySensor ERD-001C-T (titanium electrode) external installationInstall 2 m downstream on the pipe from eFLOW
ERD-001C-T (titanium electrode)Already installed in the case (built-in)
Equipments
Comes withCO2 slow leak (hollow fiber capillary) valve
CO2 gas auto purge (timer controlled), manual purge (pushbutton switch)
- Carbon dioxide filter
- Water leak sensor (reflective, water-absorbent paper type)
Options - CO2 gas pressure sensor, warning light
* (1) Please contact the sales representatives for settings below 0. 2MΩ⋅cm. Settings of 1.0 MΩ⋅cm or higher are possible, but accuracy is not guaranteed.
Specifications
Performance,Characteristics
RangeofflowRatetobeUsedforEacheFLOWModel
When setting
When setting
PressurelossforeachmodelRangeofflowratetobeusedforeacheFLOWmodel
*Theresistivityperformanceduringflowratefluctuationisnotguaranteed.*Thegraphsprovidedareforreferenceonly.Theperformanceandcharacteristicsmayvarywithoperatingconditions.
PressureLossforEachModel