Main Menu Default Value Unit
Display Contrast 32
System
Language Options NA
Arms
First Arm Number 1
RIT Panel
RIT Panel Enable
Lamps State Boot ALL OFF
Lamp State Idle RED Steady
Lamp State Auth AMBER Steady
Lamp State Wait Ack Amber Flashing
Lamp State Wait Start GREEN Flashing
Lamp State Loading GREEN Steady
Lamp State Error RED Flashing
Lamp State Batch Over AMBER Flashing
System of Units
System of Units Metric - ISO units
Corrected base Temp Base 15 deg C
Litre/Liter Spelling Litre
Volume Decimals 1
Batch TypeBatch Type Gross
Transaction Number
Transaction Number xxxx
Overwrite oldest trans Enable
Clock
Year xxxx
Month xx
Day xx
Hours xx
Minutes xx
Display Date Format DD/MM/YYYY
Authorizations / Pins
Setup Password 6789
Manager Reset 9876
PIN password 1234
W&M password 4321
Personnel Authorization PIN
Vehicle Authorization None
master Authorization PIN
Master to TAS override Enable
Hardware test via 8 key Enable
Timeouts
Keyboard time out 0
Clear / Reconnect 0
Bay Number
Bay Number xxx
Power Fail restart
Restart after power fail Enable
Show officer Card
Show officer Card Enable
Test Mode Disable
Demo Mode Disable
Automated Proving Disable
Illegal Access Disable
Alarm on Fault Enable
Ask Compt number Enable
Ask return quantity Disable
Ask Load number Disable
BATCH CONTROLLER CONFIGURATION PARAMETERS
General Setup
LOADING OPTIONS
Submenus
Page 1 OF 7
8/12/2019 BC-Config
2/7
Ask Truck Number Enable
Multiple loads per arm Enable
Ask Preset quantity Enable
Max preset quantity Enable
GP Input 1 - CA20/CA19
Input type Permissive
Input function Emergency Stop
Loading effect Pause Loading
GP Input 2 - CA21/CA19
Input type Permissive
Input function Overfill/Ground
Loading effect Pause Loading
GP Input 3 - CA22/CA19
Input type None
GP Input 4 - CA23/CA19
Input type Arm input
Input function Arm input 1
Select Arm Arm 1
Loading effect Pause Loading
GP Input 5 - CA25/CA24
Input type None
GP Input 6 - CA26/CA24
Input type NoneGP Input 7 - CA27/CA24
Input type None
GP Input 8 - CA28/CA24
Input type None
GP Input 9 - CB20/CB19
Input type None
GP Input 10 - CB21/CB19
Input type None
GP Input 11 - CB22/CB19
Input type RIT Input
Input function RIT Start
Select Arm Arm 1
GP Input 12 - CB23/CB19
Input type RIT Input
Input function RIT Ack
Select Arm Arm 1
GP Input 13 - CB25/CB24
Input type RIT Input
Input function RIT STOP
Select Arm Arm 1
GP Input 14 - CB26/CB24
Input type None
GP Input 15 - CB27/CB24
Input type None
GP Input 15 - CB28/CB24
Input type None
GP Output 1 A9/A10 None
GP Output 2 A11/A12 None
GP Output 3 A13/A17
GP Output 3 Stream ControlStream Control Pump demand
Pump demand Stream 1
GP output 3 Condition Normally open
GP Output 4 A14/A17
GP Output 4 Stream Control
Stream Control Pump demand
Pump demand Stream 2
GP output 4 Condition Normally open
GENERAL PURPOSE INPUTS
GENERAL PURPOSE OUTPUTS
Page 2 OF 7
8/12/2019 BC-Config
3/7
GP Output 5 A15/A17 None
GP Output 6 A16/A17 None
GP Output 7 BA1/BA2
GP Output 7 Control Valve
Control Valve DCV Inlet/ Slow flow
DCV Inlet/ Slow flow Stream 1
GP output 7 Condition Normally open
GP Output 8 BA3/BA2
GP Output 8 Control Valve
Control Valve DCV Outlet/ High flow
DCV Outlet/ High flow Stream 1
GP output 8 Condition Normally open
GP Output 9 BA4/BA5
GP Output 9 Control Valve
Control Valve DCV Inlet/ Slow flow
DCV Inlet/ Slow flow Stream 2
GP output 9 Condition Normally open
GP Output 10 BA6/BA5
GP Output 10 Control Valve
Control Valve DCV Outlet/ High flow
DCV Outlet/ High flow Stream 2
GP output 10 Condition Normally open
GP Output 11 BA7/BA8
GP Output 11 Internal AdditiveInternal Additive Int Addtv pulse
Int Addtv pulse Additive 1
GP output 11 Condition Normally open
GP Output 12 BA9/BA8
GP Output 12 Internal Additive
Internal Additive Int Addtv pulse
Int Addtv pulse Additive 2
GP output 12 Condition Normally open
GP Output 13 BA10/BA11 None
GP Output 14 BA12/BA11 None
GP Output 15 BA13/BA14
GP Output 15 Internal Additive
Internal Additive Int Additive pump
Int Additive pump Additive 1
GP output 15 Condition Normally open
GP Output 16 BA15/BA14
GP Output 16 Internal Additive
Internal Additive Int Additive pump
Int Additive pump Additive 2
GP output 16 Condition Normally open
GP Output 17 BA16/BA17 None
GP Output 18 BA18/BA17 None
GP Output 19 BB1/BB2 None
GP Output 20 BB3/BB2 None
GP Output 21 BB4/BB5 None
GP Output 22 BB6/BB5 None
GP Output 23 BB7/BB8 None
GP Output 24 BB9/BB8 None
GP Output 25 BB10/BB11
GP Output 25 RIT
RIT RIT GreenRIT Green Arm 1
GP output 25 Condition Normally Open
GP Output 26 BB12/BB14
GP Output 26 RIT
RIT RIT Amber
RIT Amber Arm 1
GP output 26 Condition Normally Open
GP Output 27 BB13/BB14
Page 3 OF 7
8/12/2019 BC-Config
4/7
GP Output 27 RIT
RIT RIT RED
RIT RED Arm 1
GP output 27 Condition Normally Open
GP Output 28 BB15/BB14 None
GP Output 29 BB16/BB17 None
GP Output 30 BB18/BB17 None
Deadman Timer Disable
Port 1
Comms Device Computer
Comms Mode RS 485
Baud Rate 19200 BPS
Parity None
Stop bits 1
Unit Address xx
Port 2
Comms Device Computer
Comms Mode RS 485
Baud Rate 19200 BPS
Parity None
Stop bits 1
Unit Address xxPort 3
Comms Device Computer
Comms Mode RS 485
Baud Rate 19200 BPS
Parity None
Stop bits 1
Unit Address xx
Terminal Automation mode
Terminal Automation mode Load Scheduling
Comms Time out 30 Sec
Options
Debug Response Disable
Initial Message
Initial Message Connect Earth
Manager Messages
Manager Reset message Standard
Deadman messages
Deadman timeout message Standard
GP input message
Arm Messages Standard
Permissive messages Standard
System Messages Standard
Opto outputs Flowmeter A
Alarm Loading effects Standard
Loading Arms
Name
Select Arm DefaultEdit HM Classif 1
Setup
Enable Arm 1 Enable
Units L & L / min
Maximum Preset 8000 Lit
Flow Control
Arm Slow Flow 300 L/Min
Slow Start Quantity 300 L
COMMUNICATIONS
CONFIGURE MESSAGES
OPTO OUTPUTS
ALARM LOADING EFFECTS
CONFIGURE ARM 1
CONFIGURE DEADMAN
Page 4 OF 7
8/12/2019 BC-Config
5/7
Arm Full flow 1500 L/Min
Alarm Setup
Blend tollerence alarm Enable
Low percentage 5
High percentage 5
Minimum Blend volume 1 L
Slow flow alarm Enable
Low percentage 20
High percentage 20
Slow flow Alarm delay 10 Sec
High Flow alarm Enable
Low percentage 20
High percentage 20
High flow Alarm delay 10 Sec
Low Flow alarm Enable
Low percentage 20
High percentage 20
Low flow Alarm delay 10 Sec
Additive Setup
Cont Add Batch On Alarm Disable
Metering Lines
Name Meter 1
K factorK Factor type Non Linear
K Factor 1 1
Freq 2 25 Hz
K Factor 2 1
Freq 3 50 Hz
K Factor 3 1
Freq 4 75 Hz
K Factor 4 1
Freq 5 100 Hz
K Factor 5 1
Signal Type
Min Linear Flow Rate 200 L/Min
Signal type meter 1 Dual
Cutoff Meter 1 1 Hz
Flowmeter input meter1 Resistor pull up
Flowmeter filter meter 1 Debounce inactive
Correction
Meter 1 Commodity type none
Pre Batch Stop quantity
Pre Batch Stop quantity 0 L
Unauthorized Flow threshold
Unauthorized Flow thr 10 L
Minimum Preset
Minimum Preset 10 L
Accumulated totals xxxx
Meter Factor
Meter 1 factor 1
Overrun quantity
Overrun quantity 10 L
Name Meter 2K factor
K Factor type Non Linear
K Factor 1 1
Freq 2 25 Hz
K Factor 2 1
Freq 3 50 Hz
K Factor 3 1
Freq 4 75 Hz
CONFIGURE LINE 2
CONFIGURE LINE 1
Page 5 OF 7
8/12/2019 BC-Config
6/7
K Factor 4 1
Freq 5 100 Hz
K Factor 5 1
Signal Type
Min Linear Flow Rate 5 L/min
Signal type meter 2 Dual
Cutoff Meter 2 1 Hz
Flowmeter input meter 2 Resistor pull up
Flowmeter filter meter 2 Debounce inactive
Correction
Meter 1 Commodity type none
Pre Batch Stop quantity
Pre Batch Stop quantity 0 L
Unauthorized Flow threshold
Unauthorized Flow thr 10 L
Minimum Preset
Minimum Preset 1 L
Accumulated totals xxxx L
Meter Factor
Meter 2 factor 1
Overrun quantity
Overrun quantity 10 L
Product Streams
No Flow time out 5 Sec
Valve type Digital
Deadband 20 L/Min
Valve slow flow 230 L/Min
Valve low flow 270 L/Min
Valve response 0.7
PreStop quantity 300 L/Min
Auto high flow Enable
Valve full flow 1500 L/min
High flow time out 10 Sec
Pump Off delay 0 Sec
No Flow time out 5 Sec
Valve type Digital
Deadband 5 L/Min
Valve slow flow 20 L/Min
Valve low flow 20 L/Min
Valve response 0.7
PreStop quantity 300 L/Min
Auto high flow Enable
Valve full flow 400 L/min
High flow time out 10 Sec
Pump Off delay 0 Sec
Additive Lines
Injection point 1
Name / Setup
Enable Injector 1 Enable
Enable Injector 1 Arm 1
Edit Additive 1 code ADDCODE 1
Pacing volume 200 LPump off delay 0 Sec
Alarm Setup
Inj 1 leaking soleniod Enable
Leaking Sol time period 5 Sec
Leaking sol vol limit 100 ml
Inj 1 No flow alarm enable
No additive flow time out 2 Sec
No of solenoid retries 2
STREAM 1
STREAM 2
INTERNAL ADDITIVE LINES
Page 6 OF 7
8/12/2019 BC-Config
7/7
Inj 1 Additive deviation enable
Additive deviation basis 10
Additive volume deviation 10
K factor
Inj 1 K factor 2
Meter Factor
Inj 1 Meter Factor 1
Injection point 2
Name / Setup
Enable Injector 2 Disable
Injection point 3
Name / Setup
Enable Injector 3 Disable
Injection point 4
Name / Setup
Enable Injector 4 Disable
Additive type
Additive Inject None
Additive Line setup No Available
Recipies
Edit Recipe Name xxxxx
Enable Recipe X Enable / DisableAssociated Loading Arm 1
Target Blend percentage 0
Additive Amount 1 x.x ppm
Additive Amount 2 x.x ppm
Additive flush volume 100 L
EXTERNAL ADDITIVE LINES
RECIPE 1 to 16