Biometric Factors Affecting Vaulting After Intraocular Collamer Lens Implantation. David Sung Yong Kang 1,2 , Jin Young Choi 1 , Hun Yang 1 , Ik Hee Ryu 1 , Hee Sun Kim 1 , Seong Bae Park 1 , Jin Kuk Kim 1 and Chan Yun Kim 2 . 1. Clean Vision Eye Center, GangNam, Seoul, Korea. 2. Yonsei University College of Medicine, Seoul, Korea. Authors have No Financial Interest in the Subject Matter of this Pos

Biometric Factors Affecting Vaulting After Intraocular Collamer Lens Implantation

  • Upload
    bela

  • View
    59

  • Download
    0

Embed Size (px)

DESCRIPTION

Biometric Factors Affecting Vaulting After Intraocular Collamer Lens Implantation. David Sung Yong Kang 1,2 , Jin Young Choi 1 , Hun Yang 1 , Ik Hee Ryu 1 , Hee Sun Kim 1 , Seong Bae Park 1 , Jin Kuk Kim 1 and Chan Yun Kim 2 . - PowerPoint PPT Presentation

Citation preview

Page 1: Biometric Factors Affecting Vaulting After Intraocular  Collamer  Lens Implantation

Biometric Factors Affecting Vaulting After Intraocular Collamer Lens Im-

plantation.

David Sung Yong Kang1,2, Jin Young Choi1, Hun Yang1, Ik Hee Ryu1, Hee Sun Kim1,

Seong Bae Park1, Jin Kuk Kim1 and Chan Yun Kim2.1. Clean Vision Eye Center, GangNam, Seoul, Korea. 2. Yonsei University College of Medicine, Seoul,

Korea.

The Authors have No Financial Interest in the Subject Matter of this Poster.

Page 2: Biometric Factors Affecting Vaulting After Intraocular  Collamer  Lens Implantation

OBJECTIVES 1. To Evaluate Pre-operative Biomet-

rics Predictive of Final ICL Vaulting.

2. To Evaluate Manufacturer Recom-mendation Lens Size on Final ICL Vault Outcome.

Page 3: Biometric Factors Affecting Vaulting After Intraocular  Collamer  Lens Implantation

METHODS Retrospective Observational Non-Interventional Case Series

Duration: 2009.9 – 2010. 4 At Least 6 months F/U

Participants: 133 Eyes of 67 pts Im-planted with 120 sized V4 Intraocu-lar Collamer Lens (ICL, Starr Surgical).

Page 4: Biometric Factors Affecting Vaulting After Intraocular  Collamer  Lens Implantation

METHODSPre-Op. Biometric Evaluation:

1. Corneal White-to-White(WTW): Keratograph (70600, Oculus)2. Anterior Chamber Depth (ACD) Measurement: A-Scan (SP-3000,Tomey,Japan)3. Sulcus-to-Sulcus Measurement(STS): Ultrasound Bio-Microscopy(UBM,Aviso,Quantel Medical) 4. Angle-to-Angle(ATA) Measurement, Angle Parameters (AOD, TISA 500 & 750) Anterior Segment Optical Coherence Tomography (OCT): (Visante OCT, Carl Zeiss Meditech, Dublin,CA)5. Anterior Chamber Volume Assessment: Pentacam (Oculus)

Post-Op. Biometric Evaluation: 1. ICL Vaulting2. Angle Parameters (AOD & TISA 500 & 750) All by Visante OCT.

Page 5: Biometric Factors Affecting Vaulting After Intraocular  Collamer  Lens Implantation

METHODSNo. of Eyes Reason Measures POD #

Weeks2 High V Exchanged # 1 & 3 2 Low V Exchanged # 4 2 Non-Patent

PI High VFurther PI # 2 & 3

5 Steroid In-duced OHTN

Anti-HTN Medication

1 F/U LossFinal In-clusion

121

Exclusion Criteria

V: Vaulting, PI:Laser Peripheral Iridotomy, OHTN: Ocular Hypertension, F/U: Follow up

Page 6: Biometric Factors Affecting Vaulting After Intraocular  Collamer  Lens Implantation

METHODS

High Vault: >750 Microns

Optimal Vault:250 – 550 Microns

Low Vault: <250 Microns

Evaluated at POD # 6 Months With Anterior Segment OCT

Page 7: Biometric Factors Affecting Vaulting After Intraocular  Collamer  Lens Implantation

Low V(n=10)

P value( Low vs Op-

timal)Optimal V

(n=87)P value

( High vs Op-timal)

High V(n=24)

Total(n=121)

Age 29.70(4.55) 0.0003 24.97 (3.69)

0.42 25.67 (4.10)

Sex(M:F) 2:8 0.49 32:55 0.67 10:14AXL 26.58

(1.11)0.09 27.22

(1.15)0.30 27.52 (1.46)

ACD 3.12 (0.18) 0.004 3.31 (0.19) 0.49 3.34 (0.20)ACV 191.8

(28.35)0.03 209.7

(22.99)0.46 205.8

(20.78)WTW 11.64

(0.11)0.0003 11.85

(0.24)0.0006 11.70 (0.17)

ATA 12.18 (0.21)

0.84 12.16

(0.32)0.003 11.94 (0.23)

STS 11.61 (0.23)

0.08 11.76 (0.21)

0.009 11.63 (0.21)

AOD500 0.44 (0.16) 0.14 0.53 (0.19) 0.35 0.57 (0.17)AOD750 0.63 (0.21) 0.11 0.76 (0.24) 0.45 0.81 (0.21)TISA500 0.15 (0.05) 0.14 0.18 (0.06) 0.43 0.19 (0.06)TISA750 0.28 (0.09) 0.11 0.34 (0.12) 0.41 0.37 (0.10)

RESULTS

The t-test Procedure; SPSS Ver12.0; p<0.05 considered Siginificant

Page 8: Biometric Factors Affecting Vaulting After Intraocular  Collamer  Lens Implantation

Specificities at Fixed Sensitivi-ties

Variable Sensitivity(%)

Specificity(%)

Cut-Off Value

WTW 85 37.5 11.65STS 81.4 39 11.56ATA 80.2 31.8 11.895

Optimal vs High Vaulters

Optimal vs Low VaultersVariable Sensitivity(

%)Specificity(

%)Cut-Off Value

WTW 85.1 22.2 11.65ACD 81.6 44.4 3.125ACV 80.5 30 188.5

WTW: White-to-white(mm), STS: Sulcus-to-Sulcus(mm), ATA: Angle-to-Angle(mm)

WTW: White-to-white(mm), ACD: Anterior Chamber Depth(mm), ACV: Anterior Chamber Volume(mm3)

Page 9: Biometric Factors Affecting Vaulting After Intraocular  Collamer  Lens Implantation

Combination of Specificities: vs High Vaulters

WTW(>11.65)

ATA(>11.895)STS(>11.56)90%

(Sensitivity > 80%)

Frequency Proportion Analysis

88.4% 83.6%

86.7%

(WTW, STS and ATA; all in mm)

Page 10: Biometric Factors Affecting Vaulting After Intraocular  Collamer  Lens Implantation

Combination of Specificities: vs Low Vaulters

WTW(>11.65)

ACV(>188.5)ACD(>3.13)93.4%

92.5% 91%

94.2%

Frequency Proportion Analysis(WTW, ACD and ACV; mm and mm3)

(Sensitivity > 80%)

Page 11: Biometric Factors Affecting Vaulting After Intraocular  Collamer  Lens Implantation

VS Manufacturer Rec-ommendations

(#Manufacturer Recommendations for All ICLs that were Finally Implanted with 120 Sized S4 ICL)

Recommenda-tion#

Low Vault

Optimal Vault

High Vault

%

115 1 21 1 19.0120 9 26 14 40.5125 0 39 9 39.7130 0 1 0 0.8

Page 12: Biometric Factors Affecting Vaulting After Intraocular  Collamer  Lens Implantation

CONCLUSIONS1. Age, ACD, ACV and WTW were significant factors in predicting Post-op Low Vaulters.

A Combination of these Factors Raised Predictability to 93.4%.

2. STS, ATA and WTW were Significant Factors in Predicting Post-op High Vaulters. A Combination of these Factors Raised Predictability to 90%.

3.Current Paradigm of Relying on ACD, WTW and STS may need to be Revised in Asian Eyes.

4. Manufacturer Guidelines cannot be Infallible in Predicting Ideal Vaulting, especially In Asian Eyes.