general requirementsTaweelah Aluminium Extrusion Company LLCAluminium Extrusion Plant KIZAD Zone KP3General Requirements-ABill Of QuantitiesITEMITEM DESCRIPTIONUNITQUANTITYUNIT RATEAMOUNT IN UAE DhsGENERAL REQUIREMENTS (Preliminaries)PAGE Nr. A/A/1Remeasured WorkThe Engineer's Site AccommodationAErection, servicing of the Engineer's Site accommodationWeekThe Contractors' Site AccommodationBErection, servicing of the Contractor's Site accommodationWeekOperatives of the EngineerCCainmanman-dayDLabourerman-dayEDriverman-dayFSecretaryman-dayGClerical assistantman-dayVehicles for the employersHProvision of vehicles for the employers (Toyota pickup)NoIProvision of vehicles for the employers (Toyota -four wheel drive)NoJMaintenance of vehicles for the employers (Toyota pickup)vehicle weekKMaintenance of vehicles for the employers (Toyota -four wheel drive)vehicle weekcarried to part summary (AED)GENERAL REQUIREMENTS (Continued.)PAGE Nr. A/A/2Progress PhotographsASet of progress photosNrCommunication Systems for the EngineerBProvision of telephonesNrCOperation and maintenance of telephonesNumber weekProject Sign BoardsDSign boardsNrLump Sum ItemsThe Contractors' Site AccommodationEErection, servicing of the Contractor's Site accommodationItem1The Engineers Site AccommodationFErection of the Engineers Site accommodationItem1GDemobilization of Engineers Site accommodationItem1Traffic Safety and ControlHTraffic safety and controlItem1Equipment for the EngineerIFurniture and furnishings for the Engineers Site accommodationItem1JOffice equipment for the Engineers useItem1KPersonal protective equipment for the Engineers use.Item1Securities and InsurancesLPerformance securityItem1MPerformance guaranteeItem1NCollateral warrantyItem1OContractors insuranceItem1Temporary Fences, Hoardings, Barriers, Screens and GatesPProvision, maintenance, removal and relocation of temporary fences, hoardings, barriers, screens and gatesItem1carried to part summary (AED)GENERAL REQUIREMENTS (Continued.)PAGE Nr. A/A/3Site ClearanceAGeneral site clearanceItem1Site Management PlansBPreparation and implementation of Construction Environmental Management Plan as per specificationsItem1CPreparation and implementation of Site Specific Safety Management PlanItem1DPreparation and implementation of Site Specific Quality Management PlanItem1MiscellaneousEAs Built DrawingsItem1FOperation and maintenance manualsItem1NB: Tenderer shall deemed to include costs of all items of Specification related to General Requirements and preliminariesContractors Separate ChargesNote: tenderer to include full description of each inserted item of Contractors Separate Charges in relation to Bill A General requirementsTo be completed as required by the Tenderer:carried to part summary (AED)PART SUMMARYSECTION SUMPAGE Nr. A/SUM/1GENERAL REQUIREMENTS (Preliminaries)PAGE Nr. A/A/1GENERAL REQUIREMENTS (Continued.)PAGE Nr. A/A/2GENERAL REQUIREMENTS (Continued.)PAGE Nr. A/A/3Total amount carried to General summary(AED)

EX1Taweelah Aluminium Extrusion Company LLCAluminium Extrusion Plant KIZAD Zone KP3Extrusion Building phase-1 (EX1)Bill Of QuantitiesITEMITEM DESCRIPTIONUNITQUANTITYUNIT RATEAMOUNT IN UAE DhsSITE WORKSECTION BPAGE Nr.EX1/B/1The contractor is required to have visited the site and fully understand the existing site conditions. The contractor is deem to have verified the extent of work and the work to be demolished. The contractor to verify with the engineer on any discripensies.No claim is allowed for contractor failure in verification of information and data and whatsoever on existing site conditions.ASite ClearanceM237820Excavation, cutting & levelling up to certain depth shown on drawings including safety consideration.BFoundations and over site excavationM3Rates onlyDisposalCLoading, transportation and disposal of unsuitable and surplus excavated material to designated place as directed by the Engineer.M3Rates onlyBackfillingDBackfilling, levelling and compaction for foundations with selected excavated material.M3Rates onlyFillingEFilling with specified material from outside, levelling and compaction.M375640Anti termite treatmentFGenerallyM235450Pile workReinforced cost in situe bored piles grade 60N/mm2 down to cut off level complete.G700 mm dia bore piles maximum depth 13.0 mNr268H500 mm dia bore piles maximum depth13.0 mNr44Cutting of pile heads.Cutting of top of piles up to cut off level including chipping of concrete and exposing the rebar, cleaning to the engineer satisfaction.I700 mm dia bore piles maximum depth 13.0 mNr268J500 mm dia bore piles maximum depth13.0 mNr44Pile testing.KAllow for testing of pile to the requirement.Item1carried to part summary (AED)CONCRETE WORKSSECTION CPAGE Nr. EX1/C/1SUBSTRUCTURESBlinding concreteA50mm thick blinding concrete (Grade 20N/mm2) including supply of the curing material (hessian) clothes & polyethylene sheet), clear water for curing of the concreteM31795Reinforced concrete of grade 40N/mm2 with SRCBFor Pile CapsM3254CFor Ground Slab 200mm thick, tie beamsM37380DConcrete pedestals of steel columnsM347ETrench 600mm deepM3209FTrench 2200mm deepM3303Trenches for fork lift/underpass 21m length x 5m wideNr3High tensile steel including cutting, bending and placement.GPile capsTon35HPedestalsTon6IGround slab including tie beamsTon332J600mm,2200mm deep trenchTon48ShutteringKVertical face of pile capeM2979LSides of Ground slab, tie beamsM2835MVertical sides of pedestalsM2407NSides of 600mm deep trenchesM21668OSides of 2200mm deep trenchesM22428PConstruction of ETP/water treatment plant complete.Item1QStone columns 1.5m c/c for soil strengtheningNr23002RConstruction of oil and water underground tanks complete.Nr2carried to part summary (AED)MASONRY WORKSSECTION DPAGE Nr. EX1/D/1The masonry work shall include fire stop and treatment around services penetration and like through wall and slab as per Engineers requirements.Concrete hollow blocks bedded jointed and pointed in bed mortar including necessary stiffeners and to the Engineers satisfaction.A250mm thick block wallM25950B200mm thick block wallM21255carried to part summary (AED)METAL WORKSSECTION EPAGE Nr. EX1/E/1Rates for all attached loos, connections, welding, cleats, brackets and all necessary fixing accessories shall deemed to have included in the rates of structural metalwork's.Structural metal worksASupply, fabricate and installation of steel structures, connection plates, clip angles, connection bolts, anchor bolts and necessary secondary members complete to the engineers satisfactionTon3425BSteel bridge walkway above equipments size 10000mm length and 1200mm width.Nr2Non structural metal worksCSupply and install steel cat laddersNr4DColumns protections 1200mm highNr14Metal Sheet roofingSupply and install steel sheeting in composite insulated panel comprising 0.7mm gauge outer sheet with 45/250 trapezoidal profile with two coats semi glass-1 PVF2 finish,50mm thick factory injected rigid closed cell polyurethane foam and 0.4mm gauge polyester finish inner galvanized steel sheet.ERoofing for phase-1M237249FEnclosure for phase-1M220005Rain water gutterSupply and install rain water gutters in accordance with drawings and specifications.GSize 400mm width x 500mm depthM1890carried to part summary (AED)WOOD WORKSSECTION FPAGE Nr. EX1/F/1Pantry Cabinetspantry base unit including concrete base ,granite top,shelves,hardwares and all necessary accessories.ASize 4800length, 850 height, 600mm widthSet1BSize 4622length, 850 height, 600mm widthSet1CSize 4170length, 850 height, 600mm widthSet1DSize 4600length, 850 height, 600mm widthSet1Top hung units including shelf,hardwares and all accessories material as per drawing,ESize 4800length, 850 height, 350mm widthSet1FSize 4622length, 850 height, 350mm widthSet1GSize 4170length, 850 height, 350mm widthSet1HSize 4600length, 850 height, 350mm widthSet1carried to part summary (AED)THERMAL AND MOISTURE PROTECTIONSECTION GPAGE Nr. EX1/G/150mm thick protection screedABelow pile capsM2322BBelow Ground slabM235450Supply & laying 1000 gauge polythene sheet.CBelow Ground slabM235450DBelow Pile CapsM2322Waterproofing treatment to top of pileE700mm diameter pilesNr268F500mm diameter pilesNr44Supply and laying of 4mm thick waterproofing membrane system with hot torch double layer including protection board.Vertical sidesGPile capsM2979HTrench pitsM24096IPedestalM2407Supply and laying of 4mm thick waterproofing membrane system with hot torch.JBelow Ground slab & tie beamsM236324KBelow Pile CapsM2322Supply and apply waterproofing liquid applied flexible cementitious waterproofing system including all related worksLWet areas such as toilet,pantry,abulation etc.M2215carried to part summary (AED)DOOR AND WINDOWSSECTION HPAGE Nr. EX1/H/1Timber doorsTimber door set comprising factory finish door frames architraves material as per finished schedules including fixing to concrete or block wall including ironmongeryASingle leaf hinged wooden door 850mm width and 2200mm height 2hrs fire rated.Nr11BSingle leaf hinged wooden door 900mm width and 2200mm height 2hrs fire rated.Nr3CSingle leaf hinged wooden door 1000mm width and 2200mm height 2hrs fire rated.Nr34Steel doorsSteel door set comprising factory finish (powder coated) door frames architraves material as per finished schedules including fixing to concrete or block wall including ironmongery.DSingle leaf hinged steel door type DS02 1000mm width and 2200mm height.Nr20To collections (AED)DOOR AND WINDOWS (Continued.)SECTION HPAGE Nr. EX1/H/2Roller shuttersSupply and installation of Rockwool in filled hot dipped galvanised steel roller shutter door with motor and powder coated mild steel shutter box with door frame, with safety barriers and all necessary fittings as per drawing.ASize (7000mm width, 5850mm height)Nr5BSize (5000mm width, 5850mm height)Nr5CSize (5150mm width, 5850mm height)Nr1DSize (1800mm width, 3150mm height)Nr1Windows for offices inside extrusionTilted doubled glazed aluminium windowsETilted doubled glazed thermally broken aluminium window unit vertically sealed Type 1200mm width and 600mm heightNr52FTilted doubled glazed thermally broken aluminium inclined window unit vertically sealed Type 4250mm width and 1500mm heightNr2Windows for extrusion buildingGSkylight, side windows size variesM25549HTriangular type windowsM282To collections (AED)CollectionsSECTION HPAGE Nr. EX1/H/3PAGE Nr. EX1/H/1PAGE Nr. EX1/H/2carried to part summary(AED)FINISHESSECTION JPAGE Nr. EX1/J/1Floor Finishes50mm thick cement sand screed to hard and smooth surface for offices onlyAunder porcelain tileM21180Bunder ceramic tilesM2215Cunder epoxy coatingM227Epoxy coatingDTo FloorM234728ETo wallsM214391Supply and lay porcelain floor tiles size (600x600) for officesFPorcelain tilesM21180Supply and lay ceramic tiles(600mmx600mm)jointed with approved adhesive and lay to approved pattern to Engineers satisfaction.GCeramic tilesM2215SkirtingPorcelain tile skirting including jointing, pointing complete to the Engineers satisfactionH70mm HighM881Plaster on walls20mm thick cement sand plaster on block or concrete wall to include plaster stop beads etc completeIInner and outer wallsM214391To collections (AED)FINISHES (Continue,,,)SECTION JPAGE Nr. EX1/J/2Ceiling Finishes for officesSupply and install 600x600mm Gypsum tiles ceiling with gypsum board border complete with all necessary fittingsA600x600 gypsum with gypsum board borderM21180Supply and install 600x600mm waterproofing Gypsum tiles ceiling with waterproofing gypsum board border complete with all necessary fittingsB600x600 waterproofing gypsum tiles with waterproofing gypsum board borderM2215To collections (AED)CollectionsSECTION JPAGE Nr. EX1/J/3PAGE Nr. EX1/J/1PAGE Nr. EX1/J/2carried to part summary(AED)ACCESSORIESSECTION KPAGE Nr. EX1/K/1MirrorsA6mm thick 600x1050mm clear mirror with marine plywood backing and stainless steel frame including all necessary fittings.etcNr6Vanity countersBsupply and installation of 30mm thick 300mm wide vanity counter with facial & backsplash including all necessary fittings.etcM6Csupply and installation of 30mm thick removable polished granite shelf at 850mm aboveFFL. (Avg.size 900x150) with all necessary fittings.Set6Supply and installation of toilet cubicles complete with door, partitions,ironmongry etc.DSize 2540x1700x2000ht with 2 partitions and 3 door.Set2Offices inside Extrusion buildingoffices structure light weight portacabin type contractor to provide the design, approvals and construction all to engineers satisfaction.EOffice No.1 at Mezzanine floor (total covered area)M2355FOffice No.2 at ground floorM2265GOffice No.4 at ground floorM2232HOffice No.4 at First floorM2232IOffice No.5 at Mezzanine floorM287JOffice No.6 at ground floorM2152KOffice No.7 at Mezzanine floorM278To collections (AED)ACCESSORIES (Continue)SECTION KPAGE Nr. EX1/K/2Glass CabinsATotal covered area=36.M2 for one cabin, contractor to provide prefabricated glass cabins of normal height as shown on drawing and to the satisfaction of engineer complete.Item6Operator desk cabinBTotal covered area=11.M2 for one cabin, contractor to provide prefabricated glass cabins of normal height as shown on drawing and to the satisfaction of engineer complete.Item2Grating to open trenchesSupply and installation of Ductile iron heavy duty gratings to open trenches complete to the engineer satisfaction.C600mm wide trenchM695D12mm wide trenchM276Glass protective screenEToughen glass protective screen 2m high with all fixing accessories as shown on drawingM232To collections (AED)CollectionsSECTION KPAGE Nr. EX1/K/3PAGE Nr. EX1/K/1PAGE Nr. EX1/K/2carried to part summary(AED)PART SUMMARYSECTION SUMPAGE Nr. EX1/SUM/1SITE WORKPAGE Nr.EX1/B/1CONCRETE WORKSPAGE Nr. EX1/C/1MASONRY WORKSPAGE Nr. EX1/D/1METAL WORKSPAGE Nr. EX1/E/1WOOD WORKSPAGE Nr. EX1/F/1THERMAL AND MOISTURE PROTECTIONPAGE Nr. EX1/G/1DOOR AND WINDOWSPAGE Nr. EX1/H/3FINISHESPAGE Nr. EX1/J/3ACCESSORIESPAGE Nr. EX1/K/3Total amount carried to General summary(AED)

EX2Taweelah Aluminium Extrusion Company LLCAluminium Extrusion Plant KIZAD Zone KP3Extrusion Building phase-2 (EX2)Bill Of QuantitiesITEMITEM DESCRIPTIONUNITQUANTITYUNIT RATEAMOUNT IN UAE DhsSITE WORKSECTION BPAGE Nr.EX2/B/1The contractor is required to have visited the site and fully understand the existing site conditions. The contractor is deem to have verified the extent of work and the work to be demolished. The contractor to verify with the engineer on any discripensies.No claim is allowed for contractor failure in verification of information and data and whatsoever on existing site conditions.ASite ClearanceM29504Excavation, cutting & levelling up to certain depth shown on drawings including safety consideration.BFoundations and over site excavationM3Rates onlyDisposalCLoading, transportation and disposal of unsuitable and surplus excavated material to designated place as directed by the Engineer.M3Rates onlyBackfillingDBackfilling, levelling and compaction for foundations with selected excavated material.M3Rates onlyFillingEFilling with specified material from outside, levelling and compaction.M319008Anti termite treatmentFGenerallyM29504Pile workReinforced cast in situ bored piles grade 60N/mm2 down to cut off level complete.G700 mm dia bore piles maximum depth 13.0 mNr67H500 mm dia bore piles maximum depth13.0 mNr3Cutting of pile heads.Cutting of top of piles up to cut off level including chipping of concrete and exposing the rebar, cleaning to the engineer satisfaction.I700 mm dia bore piles maximum depth 13.0 mNr67J500 mm dia bore piles maximum depth13.0 mNr3Pile testing.KAllow for testing of pile to the requirement.Item1Includedcarried to part summary (AED)CONCRETE WORKSSECTION CPAGE Nr. EX2/C/1SUBSTRUCTURESBlinding concreteA50mm thick blinding concrete (Grade 20N/mm2) including supply of the curing material (hessian) clothes & polyethylene sheet), clear water for curing of the concreteM3479Reinforced concrete of grade 40N/mm2 with SRCBFor Pile CapsM358CFor Ground Slab 200mm thickM31931DConcrete pedestals of steel columnsM311ETrench 600mm deepM3100FTrench 2200mm deepM360High tensile steel including cutting, bending and placement.GPile capsTon8HPedestalsTon2IGround slab includingTon173J600mm,2200mm deep trenchTon15ShutteringKVertical face of pile capeM2224LSides of Ground slabM234MVertical sides of pedestalsM293NSides of 600mm deep trenchesM2800OSides of 2200mm deep trenchesM2475PConstruction of oil and water underground tanks complete.Nr4QStone columns 1.5m c/c for soil improvementNr5257carried to part summary (AED)MASONRY WORKSSECTION DPAGE Nr. EX2/D/1The masonry work shall include fire stop and treatment around services penetration and like through wall and slab as per Engineers requirements.Concrete hollow blocks bedded jointed and pointed in bed mortar including necessary stiffeners and to the Engineers satisfaction.A200mm thick block wallM2340carried to part summary (AED)METAL WORKSSECTION EPAGE Nr. EX2/E/1Rates for all attached loos,connections,welding,cleats,brackets and all necessary fixing accessories shall deemed to have included in the rates of structural metalwork's.Structural metal worksASupply, fabricate and installation of steel structures, connection plates, clip angles, connection bolts, anchor bolts and necessary secondary members complete to the engineers satisfactionTon783BSteel bridge walkway above equipments size 10000mm length and 1200mm width.Nr2Non structural metal worksCSupply and install steel cat laddersNr1Metal Sheet roofingSupply and install steel sheeting in composite insulated panel comprising 0.7mm gauge outer sheet with 45/250 trapezoidal profile with two coats semi glass-1 PVF2 finish,50mm thick factory injected rigid closed cell polyurethane foam and 0.4mm gauge polyesDRoofing for phase-2M28514EEnclosure for phase-2M23783Rain water gutterSupply and install rain water gutters in accordance with drawings and specifications.FSize 400mm width x 500mm depthM378carried to part summary (AED)THERMAL AND MOISTURE PROTECTIONSECTION GPAGE Nr. EX2/G/150mm thick protection screedABelow pile capsM274BBelow Ground slabM29504Supply & laying 1000 gauge polythen sheet.CBelow Ground slabM29504DBelow Pile CapsM274Waterproofing treatment to top of pileE700mm diameter pilesNr67F500mm diameter pilesNr3Supply and laying of 4mm thick waterproofing membrane system with hot torch double layer including protection board.Vertical sidesGPile capsM2224HTrench pitsM21275IPedestalM293Supply and laying of 4mm thick waterproofing membrane system with hot torch.JBelow Ground slabM29504KBelow Pile CapsM274carried to part summary (AED)DOOR AND WINDOWSSECTION HPAGE Nr. EX2/H/1Steel doorsSteel door set comprising factory finish (powder coated) door frames architraves material as per finished schedules including fixing to concrete or block wall including ironmongery.ASingle leaf hinged steel door type DS02 1000mm width and 2200mm height.Nr5Roller shuttersSupply and installation of Rockwool in filled hot dipped galvanised steel roller shutter door with motor and powder coated mild steel shutter box with door frame, with safety barriers and all necessary fittings as per drawing.BSize (7000mm width, 5850mm height)Nr1Windows for extrusion buildingCSkylight, side windows size variesM21205DTriangular type windowsM283carried to part summary (AED)FINISHESSECTION JPAGE Nr. EX2/J/1Floor Finishes50mm thick cement sand screed to hard and smooth surface for offices onlyAunder porcelain tileM294Epoxy coatingBTo FloorM28765CTo wallsM2678Supply and lay porcelain floor tiles size (600x600) for officesDPorcelain tilesM294SkirtingPorcelain tile skirting including jointing, pointing complete to the Engineers satisfactionE70mm HighM75Plaster on walls20mm thick cement sand plaster on block or concrete wall to include plaster stop beads etc completeFInner and outer wallsM2678Ceiling Finishes for officesSupply and install 600x600mm Gypsum tiles ceiling with gypsum board border complete with all necessary fittingsG600x600 gypsum with gypsum board borderM294carried to part summary (AED)ACCESSORIESSECTION KPAGE Nr. EX2/K/1Glass CabinsATotal covered area=36.M2 for one cabin, contractor to provide prefabricated glass cabins of normal height as shown on drawing and to the satisfaction of engineer complete.Item2Operator desk cabinBTotal covered area=11.M2 for one cabin, contractor to provide prefabricated glass cabins of normal height as shown on drawing and to the satisfaction of engineer complete.Item2Grating to open trenchesSupply and installation of Ductile iron heavy duty gratings to open trenches complete to the engineer satisfaction.C600mm wide trenchM333D12mm wide trenchM54Glass protective screenEToughen glass protective screen 2m high with all fixing accessories as shown on drawingM232To collections (AED)PART SUMMARYSECTION SUMPAGE Nr. EX2/SUM/1SITE WORKPAGE Nr.EX2/B/1CONCRETE WORKSPAGE Nr. EX2/C/1MASONRY WORKSPAGE Nr. EX2/D/1METAL WORKSPAGE Nr. EX2/E/1THERMAL AND MOISTURE PROTECTIONPAGE Nr. EX2/G/1DOOR AND WINDOWSPAGE Nr. EX2/H/1FINISHESPAGE Nr. EX2/J/1ACCESSORIESPAGE Nr. EX2/K/1Total amount carried to General summary(AED)

EX3Taweelah Aluminium Extrusion Company LLCAluminium Extrusion Plant KIZAD Zone KP3Extrusion Building phase-3 (EX3)Bill Of QuantitiesITEMITEM DESCRIPTIONUNITQUANTITYUNIT RATEAMOUNT IN UAE DhsSITE WORKSECTION BPAGE Nr.EX3/B/1The contractor is required to have visited the site and fully understand the existing site conditions. The contractor is deem to have verified the extent of work and the work to be demolished. The contractor to verify with the engineer on any discripensies.No claim is allowed for contractor failure in verification of information and data and whatsoever on existing site conditions.ASite ClearanceM28634Excavation, cutting & levelling up to certain depth shown on drawings including safety consideration.BFoundations and over site excavationM3Rates onlyDisposalCLoading, transportation and disposal of unsuitable and surplus excavated material to designated place as directed by the Engineer.M3Rates onlyBackfillingDBackfilling, levelling and compaction for foundations with selected excavated material.M3Rates onlyFillingEFilling with specified material from outside, levelling and compaction.M317268Anti termite treatmentFGenerallyM28634Pile workReinforced cost in situe bored piles grade 60N/mm2 down to cut off level complete.G700 mm dia bore piles maximum depth 13.0 mNr75H500 mm dia bore piles maximum depth13.0 mNr6Cutting of pile heads.Cutting of top of piles up to cut off level including chipping of concrete and exposing the rebar, cleaning to the engineer satisfaction.I700 mm dia bore piles maximum depth 13.0 mNr75J500 mm dia bore piles maximum depth13.0 mNr6Pile testing.KAllow for testing of pile to the requirement.Item1Includedcarried to part summary (AED)CONCRETE WORKSSECTION CPAGE Nr. EX3/C/1SUBSTRUCTURESBlinding concreteA50mm thick blinding concrete (Grade 20N/mm2) including supply of the curing material (hessian) clothes & polyethylene sheet), clear water for curing of the concreteM3432Reinforced concrete of grade 40N/mm2 with SRCBFor Pile CapsM351CFor Ground Slab 200mm thick, tie beamsM31787DConcrete pedestals of steel columnsM39ETrench 600mm deepM350FTrench 2200mm deepM392High tensile steel including cutting, bending and placement.GPile capsTon7HPedestalsTon1IGround slab including tie beamsTon80J600mm,2200mm deep trenchTon10KShutteringLVertical face of pile capeM2198MSides of Ground slab, tie beamsM2145NVertical sides of pedestalsM281OSides of 600mm deep trenchesM2398PSides of 2200mm deep trenchesM2740Q900mm dia stone columns 1.5m c/c for soil strengtheningNr4600RConstruction of oil and water underground tanks complete.Nr2carried to part summary (AED)MASONRY WORKSSECTION DPAGE Nr. EX3/D/1The masonry work shall include fire stop and treatment around services penetration and like through wall and slab as per Engineers requirements.Concrete hollow blocks bedded jointed and pointed in bed mortar including necessary stiffeners and to the Engineers satisfaction.A200mm thick block wallM2581carried to part summary (AED)METAL WORKSSECTION EPAGE Nr. EX3/E/1Rates for all attached loos,connections,welding,cleats,brackets and all necessary fixing accessories shall deemed to have included in the rates of structural metalwork's.Structural metal worksASupply, fabricate and installation of steel structures, connection plates, clip angles, connection bolts, anchor bolts and necessary secondary members complete to the engineers satisfactionTon742Non structural metal worksBSupply and install steel cat laddersNr1Metal Sheet roofingSupply and install steel sheeting in composite insulated panel comprising 0.7mm gauge outer sheet with 45/250 trapezoidal profile with two coats semi glass-1 PVF2 finish,50mm thick factory injected rigid closed cell polyurethane foam and 0.4mm gauge polyesCRoofing for phase-3M27450DEnclosure for phase-3M23310Rain water gutterSupply and install rain water gutters in accordance with drawings and specifications.Size 400mm width x 500mm depthM432carried to part summary (AED)WOOD WORKSSECTION FPAGE Nr. EX3/F/1Pantry Cabinetspantry base unit including concrete base ,granite top,shelves,hardwares and all necessary accessories.ASize 3720length, 850 height, 600mm widthSet1Top hung units including shelf,hardwares and all accessories material as per drawing,BSize 3720length, 850 height, 350mm widthSet1carried to part summary (AED)THERMAL AND MOISTURE PROTECTIONSECTION GPAGE Nr. EX3/G/150mm thick protection screedABelow pile capsM264BBelow Ground slabM28634Supply & laying 1000 gauge polythene sheet.CBelow Ground slabM28634DBelow Pile CapsM264Waterproofing treatment to top of pileE700mm diameter pilesNr75F500mm diameter pilesNr6Supply and laying of 4mm thick waterproofing membrane system with hot torch double layer including protection board.Vertical sidesGPile capsM2196HTrench pitsM21138IPedestalM281Supply and laying of 4mm thick waterproofing membrane system with hot torch.JBelow Ground slab & tie beamsM28634KBelow Pile CapsM264Supply and apply waterproofing liquid applied flexible cementitious waterproofing system including all related worksLWet areas such as toilet, pantry. etc.M230carried to part summary (AED)DOOR AND WINDOWSSECTION HPAGE Nr. EX3/H/1Timber doorsTimber door set comprising factory finish door frames architraves material as per finished schedules including fixing to concrete or block wall including ironmongeryASingle leaf hinged wooden door 850mm width and 2200mm height 2hrs fire rated.Nr1BSingle leaf hinged wooden door 1000mm width and 2200mm height 2hrs fire rated.Nr6Steel doorsSteel door set comprising factory finish (powder coated) door frames architraves material as per finished schedules including fixing to concrete or block wall including ironmongery.CSingle leaf hinged steel door type DS02 1000mm width and 2200mm height.Nr4To collections (AED)DOOR AND WINDOWS (Continued.)SECTION HPAGE Nr. EX3/H/2Roller shuttersSupply and installation of Rockwool in filled hot dipped galvanised steel roller shutter door with motor and powder coated mild steel shutter box with door frame, with safety barriers and all necessary fittings as per drawing.ASize (7000mm width, 5850mm height)Nr1BSize (1800mm width, 3150mm height)Nr1Windows for offices inside extrusionTilted doubled glazed aluminium windowsCTilted doubled glazed thermally broken aluminium window unit vertically sealed Type 1200mm width and 600mm heightNr5Windows for extrusion buildingDSkylight, side windows size variesM2783ETriangular type windowsM294To collections (AED)CollectionsSECTION HPAGE Nr. EX3/H/3PAGE Nr. EX1/H/1PAGE Nr. EX1/H/2carried to part summary(AED)FINISHESSECTION JPAGE Nr. EX3/J/1Floor Finishes50mm thick cement sand screed to hard and smooth surface for offices onlyAunder porcelain tileM2305Bunder ceramic tilesM230Epoxy coatingCTo FloorM28160DTo wallsM21163Supply and lay porcelain floor tiles size (600x600) for officesEPorcelain tilesM2305Supply and lay ceramic tiles(600mmx600mm)jointed with approved adhesive and lay to approved pattern to Engineers satisfaction.FCeramic tilesM230SkirtingPorcelain tile skirting including jointing, pointing complete to the Engineers satisfactionG70mm HighM202Plaster on walls20mm thick cement sand plaster on block or concrete wall to include plaster stop beads etc completeHInner and outer wallsM21163To collections (AED)FINISHES (Continue,,,)SECTION JPAGE Nr. EX3/J/2Ceiling Finishes for officesSupply and install 600x600mm Gypsum tiles ceiling with gypsum board border complete with all necessary fittingsA600x600 gypsum with gypsum board borderM2305Supply and install 600x600mm waterproofing Gypsum tiles ceiling with waterproofing gypsum board border complete with all necessary fittingsB600x600 waterproofing gypsum tiles with waterproofing gypsum board borderM230To collections (AED)CollectionsSECTION JPAGE Nr. EX3/J/3PAGE Nr. EX3/J/1PAGE Nr. EX3/J/2carried to part summary(AED)ACCESSORIESSECTION KPAGE Nr. EX3/K/1MirrorsA6mm thick 600x1050mm clear mirror with marine plywood backing and stainless steel frame including all necessary fittings.etcNr1Vanity countersBsupply and installation of 30mm thick 300mm wide vanity counter with facial & backsplash including all necessary fittings.etcM2Csupply and installation of 30mm thick removable polished granite shelf at 850mm aboveFFL. (Avg.size 900x150) with all necessary fittings.Set1Offices inside Extrusion buildingoffices structure light weight portacabin type contractor to provide the design, approvals and construction all to engineers satisfaction ( Note:-Floor & ceiling finishes are already calculated.)DOffice No.3 at ground floorM2264To collections (AED)ACCESSORIES (Continue)SECTION KPAGE Nr. EX3/K/2Glass CabinsATotal covered area=36.M2 for one cabin, contractor to provide prefabricated glass cabins of normal height as shown on drawing and to the satisfaction of engineer complete.Item2Operator desk cabinBTotal covered area=11.M2 for one cabin, contractor to provide prefabricated glass cabins of normal height as shown on drawing and to the satisfaction of engineer complete.Item2Grating to open trenchesSupply and installation of Ductile iron heavy duty gratings to open trenches complete to the engineer satisfaction.C600mm wide trenchM166D1200mm wide trenchM84To collections (AED)CollectionsSECTION JPAGE Nr. EX3/K/3PAGE Nr. EX3/K/1PAGE Nr. EX3/K/2carried to part summary(AED)PART SUMMARYSECTION SUMPAGE Nr. EX3/SUM/1SITE WORKPAGE Nr.EX3/B/1CONCRETE WORKSPAGE Nr. EX3/C/1MASONRY WORKSPAGE Nr. EX3/D/1METAL WORKSPAGE Nr. EX3/E/1WOOD WORKSPAGE Nr. EX3/F/1THERMAL AND MOISTURE PROTECTIONPAGE Nr. EX3/G/1DOOR AND WINDOWSPAGE Nr. EX3/H/3FINISHESPAGE Nr. EX3/J/3ACCESSORIESPAGE Nr. EX3/K/3Total amount carried to General summary(AED)

M.ATaweelah Aluminium Extrusion Company LLCAluminium Extrusion Plant KIZAD Zone KP3Main Admin Building-(M.A)Bill Of QuantitiesITEMITEM DESCRIPTIONUNITQUANTITYUNIT RATEAMOUNT IN UAE DhsSITE WORKSECTION BPAGE Nr. M.A/B/1The contractor is required to have visited the site and fully understand the existing site conditions. The contractor is deem to have verified the extent of work and the work to be demolished. The contractor to verify with the engineer on any discripensies.No claim is allowed for contractor failure in verification of information and data and whatsoever on existing site conditions.ASite ClearanceM2950Excavation, cutting & levelling up to certain depth shown on drawings including safety consideration.BFoundations and over site excavationM3Rates onlyDisposalCLoading, transportation and disposal of unsuitable and surplus excavated material to designated place as directed by the Engineer.M3Rates onlyBackfillingDBackfilling, levelling and compaction for foundations with selected excavated material.M3Rates onlyFillingFilling with specified material from outside, levelling and compaction.M31900EGenerallyM2920Pile workReinforced cost in situe bored piles down to cut off level complete.F500 mm dia bore piles maximum depth 13.0 mNr66Cutting of pile heads.Cutting of top of piles up to cut off level including chipping of concrete and exposing the rebar, cleaning to the engineer satisfaction.G500 mm dia bore piles maximum depth 13.0 mNr66Pile testing.HAllow for testing of pile to the requirement.Item1Includedcarried to part summary (AED)CONCRETE WORKSSECTION CPAGE Nr. M.A/C/1SUBSTRUCTURESA50mm thick blinding concrete (Grade 20N/mm2) including supply of the curing material (hessian) cloth & polyethylene sheet), clear water for curing of the concreteM347Reinforced concrete of grade 40N/mm2BFor Pile CapsM387CFor Ground Slab 250mm thick, tie beamsM3292DHigh tensile steel including cutting, bending and placement.Ton37ShutteringEVertical face of pile capsM2174FSides of Ground slab, tie beamsM2331To collections (AED)CONCRETE WORKS (continued.)SECTION CPAGE Nr. M.A/C/2SUPER STRUCTURESReinforced concrete of grade 40N/mm2AColumnsM3125Suspended beams1329BFirst floorM314CSecond floorM316DSuspended Slab250mm thick first, second and roof slabM3513E150mm thick roof slabM311Parapet wallsFsecond floor and roof floor 250x1200mmM398GLift core wall 250mm thickM3193HStair soffit slab & stepsM328IHigh tensile steel including cutting, bending and placement.Ton193ShutteringJVertical sides of columns.M2863KSides and soffit of suspended beams.M2305LSoffit of suspended slab.M22379MVertical sides for lift walls, stair walls.M21160Nvertical sides of parapet walls.M21032To collections (AED)CollectionsSECTION CPAGE Nr. M.A/C/3PAGE Nr. M.A/C/1PAGE Nr. M.A/C/2carried to part summary(AED)MASONRY WORKSSECTION DPAGE Nr. M.A/D/1The masonry work shall include fire stop and treatment around services penetration and like through wall and slab as per Engineers requirements.Concrete hollow blocks bedded jointed and pointed in bed mortar including necessary stiffeners and to the Engineers satisfaction.A250mm thick block wallM21150B200mm thick block wallM2495C100mm thick block wallM21640carried to part summary (AED)METAL WORKSSECTION EPAGE Nr. M.A/E/1Non structural metal worksASupply and install steel cat laddersNr4Handrail and balustrade wallSupply and install stainless steel railing to staircaseMBStaircase1 & 2 (950mm high)M45CFor external stair at entranceM5DAt the end of first floor corridor.2LouversEHigh polished Stainless steel profile at the entranceM264Aluminium claddingSupply and install 4mm thick aluminium composite panel claddingFExternal faadeM22119GcolumnsM228Glass Railing BalustradeSupply and fix 20mm thick tempered glass railing fixed in aluminium channel with stainless steel coping.HAt first floor 1100mm highM25carried to part summary (AED)WOOD WORKSSECTION FPAGE Nr. M.A/F/1Pantry Cabinetspantry base unit including concrete base ,granite top,shelves,hardwares and all necessary accessories.ASize 4400length, 850 height, 600mm widthSet1BSize 2850length, 850 height, 600mm widthSet1CSize 3300length, 850 height, 600mm widthSet1Top hung units including shelf,hardwares and all accessories material as per drawing,DSize 4400length, 850 height, 350mm widthSet1ESize 2850length, 850 height, 350mm widthSet1FSize 3300length, 850 height, 350mm widthSet1Reception CounterCounter Base unit including shelves, hardware and all accessoriesGSize 9500mm lengthx770mm hightx500mm wide.Set1Kitchen counter base unit including shelves,hardwares and all accessories.HSize 6700mm lengthx770mm hightx600mm wide.Set1ISize 4200mm lengthx770mm hightx600mm wide.Set1Top hung units including shelf,hardwares and all accessories material as per drawing,JSize 4200mm lengthx870mm hightx350mm wide at caf kitchen.Set1carried to part summary (AED)THERMAL AND MOISTURE PROTECTIONSECTION GPAGE Nr. M.A/G/150mm thick protection screedABelow pile capsM283BBelow Ground slabM2920Supply and laying of 4mm thick waterproofing membrane system with hot torch double layer including protection board.HorizontalCBelow Ground slabM2950DBelow Pile CapsM283VerticalESides of pile capsM2174Waterproofing treatment to top of pileF500mm diameter pilesNr66Supply and laying of roof waterproofing system comprising of 45mm thick polyurethane foam with 48KG/m3 density, one layer polytex liquid U.V protection coat, one layer of 13mm polyfab filter material.GFor roof slabM21070H200mm high upturn under skirtingM26080mm thick protection concrete screed to receive roof tiles.IUnder Terrazzo TilesM21070Supply and apply waterproofing liquid applied flexible cementations waterproofing system including all related worksJWet areas such as toilet,pantry,ablution etc.M2243carried to part summary (AED)DOOR AND WINDOWSSECTION HPAGE Nr. M.A/H/1Timber doorsTimber door set comprising factory finish door frames architraves material as per finished schedules including fixing to concrete or block wall including ironmongeryADouble leaf hinged wooden door type DW01 1600mm width and 2200mm height 2hrs fire rated.Nr12BSingle leaf hinged wooden door type DW02: 1000mm width and 2200mm height 2hrs fire rated.Nr28CSingle leaf hinged wooden door type DW03: 900mm width and 2000mm height 2hrs fire rated.Nr11DSingle leaf hinged wooden door type DW04: 900mm width and 2200mm height 2hrs fire rated.Nr4ESingle leaf hinged wooden door type DW05: 1000mm width and 2200mm height 1hrs fire rated.Nr12FSingle leaf hinged wooden door type DW06: 1000mm width and 2200mm height 2hrs fire rated.Nr4GSingle leaf hinged wooden door type DW07: 1000mm width and 2200mm height 2hrs fire rated.Nr3HSingle leaf hinged wooden door type DW08: 1000mm width and 2200mm height non fire rated.Nr2ISingle leaf sliding wooden door type DW09: 1000mm width and 2200mm height non fire rated.Nr2Steel doorsSteel door set comprising factory finish (powder coated) door frames architraves material as per finished schedules including fixing to concrete or block wall including ironmongery.JDouble leaf hinged steel door type DS01 1800mm width and 2200mm height 2hrs fire rated.Nr6KSingle leaf hinged steel door type DS02 1000mm width and 2200mm height 2hrs fire rated.Nr1To collections (AED)DOOR AND WINDOWS (Continued.)SECTION HPAGE Nr. M.A/H/2Glass DoorsGlass door set comprising factory finish (hairline) stainless steel door frames, material as per finished schedules including fixing to concrete or block wall including ironmongery.ASingle leaf hinged glass door type DG01: 2850mm width and 2200mm height with two fixed panels.Nr2BDouble leaf hinged glass door type DG02 1800mm width and 2200mm height.Nr2CDouble leaf hinged glass door type DG03: 3200mm width and 2200mm height with two fixed panels.NrDSingle leaf hinged glass door type DG04: 3850mm width and 2200mm height with three fixed panels.Nr1Aluminium DoorAluminium door set comprising factory finish (powder coated) aluminium door frames, material as per finished schedules including fixing to concrete or block wall including ironmongery.EDouble leaf hinged aluminium door type DA01: 1600mm width and 2200mm height.Nr1WindowsTilted doubled glazed aluminium windowsFTilted doubled glazed thermally broken aluminium window unit vertically sealed Type AW01. 1200mm width and 2400mm heightNr26GTilted doubled glazed thermally broken aluminium window unit vertically sealed Type AW02. 900mm width and 2400mm heightNr5HTilted doubled glazed thermally broken aluminium window unit vertically sealed Type AW03. 600mm width and 2400mm heightNr3To collections (AED)CollectionsSECTION HPAGE Nr. M.A/H/3PAGE Nr. A/H/1PAGE Nr. A/H/2carried to part summary(AED)FINISHESSECTION JPAGE Nr. M.A/J/1Floor Finishes50mm thick cement sand screed to hard and smooth surfaceAunder porcelain tileM21230Bunder ceramic tilesM2243Cunder epoxy coatingM296Dunder marble tilesM2423Eunder granite tilesM2117Epoxy coatingFTo service areaM296Supply and lay porcelain floor tiles size (600x600)GPorcelain tilesM21230Supply and lay ceramic tiles(600mmx600mm)jointed with approved adhesive and lay to approved pattern to Engineers satisfaction.HCeramic tilesM2243Supply and lay marble tiles, jointed with approved adhesive and lay to approved pattern to Engineers satisfaction.IMarble tilesM2423Supply and lay Granite tiles(600mmx600mm)jointed with approved adhesive and lay to approved pattern to Engineers satisfaction.JGranite tilesM2117Supply and lay 28mm thick Terrazzo tiles(300mmx300mm)jointed with approved adhesive and lay to approved pattern to Engineers satisfaction.KTerrazzo tilesM21070To collections (AED)FINISHES (Continue,,,)SECTION JPAGE Nr. M.A/J/2SkirtingPorcelain tile skirting including jointing, pointing complete to the Engineers satisfactionA70mm HighM809Epoxy coating skirting complete to the Engineers satisfactionB100mm HighM187Ceramic tile skirting including jointing, pointing complete to the Engineers satisfactionC70mm HighM6Terrazzo tile skirting including jointing, pointing complete to the Engineers satisfactionD200mm HighM297Granite tile skirting including jointing, pointing complete to the Engineers satisfactionE70mm HighM107WALL FINISHESInternal wall finishes20mm thick cement sand plaster on block or concrete wall to include plaster stop beads etc completeFTo receive washable emulsion paintM24083GTo receive epoxy paintM2483HTo receive Ceramic wall tilesM21174ITo receive Marble tilesM2220Supply and lay ceramic tiles(600mmx600mm)jointed with approved adhesive and lay to approved pattern to Engineers satisfaction.JCeramic tilesM21174Supply and lay marble tiles, jointed with approved adhesive and lay to approved pattern to Engineers satisfaction.KMarble tilesM2220Supply and apply washable emulsion paint to plaster surface including all preparations complete to the Engineers satisfaction.LWashable emulsion paintM24083Supply and apply Epoxy paint to plaster surface including all preparations complete to the Engineers satisfaction.MEpoxy coating on wallsM2483To collections (AED)FINISHES (Continue,,,)SECTION JPAGE Nr. M.A/J/3Ceiling FinishesCement plaster to soffitATo receive washable emulsionM2100BTo receive epoxy paintM2113Supply and install 600x600mm Gypsum tiles ceiling with gypsum board border complete with all necessary fittingsC600x600 gypsum with gypsum board borderM2565Supply and install 600x600mm waterproofing Gypsum tiles ceiling with waterproofing gypsum board border complete with all necessary fittingsD600x600 waterproofing gypsum tiles with waterproofing gypsum board borderM2182Supply and install 300x1200mm Metal tiles ceiling complete with all necessary fittingsE300x1200 Metal tilesM246Supply and install Decorative ceiling complete with all necessary fittings and to The Engineers satisfactionFType C07 ceilingM2583Supply and apply emulsion paint to ceiling including all necessary preparation and to The Engineers satisfactionGType C03 ceilingM2100Supply and apply Epoxy paint to ceiling including all necessary preparation and to The Engineers satisfactionHType C04 ceilingM2113Curtain WallsIReflected blue double glazed curtain wall including all necessary fittings and complete as shown in the drawing and to the Engineers satisfaction.M2700To collections (AED)CollectionsSECTION JPAGE Nr. M.A/J/4PAGE Nr. M.A/J/1PAGE Nr. M.A/J/2PAGE Nr. M.A/J/3carried to part summary(AED)ACCESSORIESSECTION KPAGE Nr. M.A/K/1MirrorsA6mm thick 600x1050mm clear mirror with marine plywood backing and stainless steel frame including all necessary fittings.etcNr30Vanity countersBsupply and installation of 30mm thick 300mm wide vanity counter with facial & backsplash including all necessary fittings.etcM31Supply and installation of toilet cubicles complete with door, partitions,ironmongry etc.CSize 2800x1800x2000ht with two partitions and 3 door.Set6DSize 1845x1800x2000ht with 1 partitions and 2 door.Set2supply and installation of 30mm thick polished granite shelf shoe rake ( size 1950x510widthx1200mm height)EMale & Female ablutionSet2supply and installation of 30mm thick polished granite step with stainless steel fixed stool Grade 316(3mm thick mirror finish) with all accessories.FMale ablutionSet1supply and installation of 30mm thick removable polished granite shelf at 850mm above FFL. (Avg.size 900x150) with all necessary fittings.GMale & Female toiletSet25carried to part summary(AED)PART SUMMARYSECTION SUMPAGE Nr. M.A/SUM/1SITE WORKPAGE Nr. M.A/B/1CONCRETE WORKSPAGE Nr. M.A/C/1MASONRY WORKSPAGE Nr. M.A/D/1METAL WORKSPAGE Nr. M.A/E/1WOOD WORKSPAGE Nr. M.A/F/1THERMAL AND MOISTURE PROTECTIONPAGE Nr. M.A/G/1DOOR AND WINDOWSPAGE Nr. M.A/H/3FINISHESPAGE Nr. M.A/J/4ACCESSORIESPAGE Nr. M.A/K/1Total amount carried to General summary(AED)

CHTaweelah Aluminium Extrusion Company LLCAluminium Extrusion Plant KIZAD Zone KP3Cast house Building (CH)Bill Of QuantitiesITEMITEM DESCRIPTIONUNITQUANTITYUNIT RATEAMOUNT IN UAE DhsSITE WORKSECTION BPAGE Nr.CH/B/1The contractor is required to have visited the site and fully understand the existing site conditions. The contractor is deem to have verified the extent of work and the work to be demolished. The contractor to verify with the engineer on any discripensies.No claim is allowed for contractor failure in verification of information and data and whatsoever on existing site conditions.ASite ClearanceM24470Compressed air stationM238Excavation, cutting & levelling up to certain depth shown on drawings including safety consideration.BFoundations and over site excavationM3Rates onlyDisposalCLoading, transportation and disposal of unsuitable and surplus excavated material to designated place as directed by the Engineer.M3Rates onlyBackfillingDBackfilling, levelling and compaction for foundations with selected excavated material.M3Rates onlyFillingEFilling with specified material from outside, levelling and compaction.M38940Anti termite treatmentFGenerallyM24470Compressed air stationM238Pile workReinforced cost in situe bored piles grade 60N/mm2 down to cut off level complete.G700mm dia bore piles maximum depth 13.0mNr34H500mm dia bore piles maximum depth 13.0mNr65Cutting of pile heads.Cutting of top of piles up to cut off level including chipping of concrete and exposing the rebar, cleaning to the engineer satisfaction.I700mm dia bore piles maximum depth 13.0mNr34J500mm dia bore piles maximum depth 13.0mNr65Pile testing.KAllow for testing of pile to the requirement.Item1Includedcarried to part summary (AED)CONCRETE WORKSSECTION CPAGE Nr. CH/C/1SUBSTRUCTURESBlinding concreteA50mm thick blinding concrete (Grade 20N/mm2) including supply of the curing material (hessian) clothes & polyethylene sheet), clear water for curing of the concreteM3224BWater tankM314CCompressed air stationM32Reinforced concrete of grade 40N/mm2 with SRCDFor Pile CapsM3140ETrench pits, underground pitsM3287FFor Ground Slab 200mm thickM3974GConcrete pedestals of steel columnsM320HWater tank (base, walls, slab)M3360ICompressed air stationM38High tensile steel including cutting, bending and placement.JPile capsTon19KFor Ground Slab 200mm thick, trench pits, underground pits. pedestalTon55LConcrete pedestals of steel columnsTon1MWater tank (base, walls, slab)Ton50NCompressed air stationTon1ShutteringOVertical face of pile capeM2138PSides of Ground slabM2101QVertical sides of pedestalsM211RVertical sides of trench pitM2420SUnderground pitM2571Twater tanksM21416UStone columns 1.5m c/c for soil strengtheningNr2854To collections (AED)CONCRETE WORKS (continued.)SECTION CPAGE Nr. CH/C/2SUPER STRUCTURESReinforced concrete of grade 40N/mm2AColumnsM33BAwning plate and compressed air station roof slabM38High tensile steel including cutting, bending and placement.CColumnsTon1DCompressed air station roof slabTon1ShutteringEVertical sides of columnsM222FCompressed air station roof slabM276To collections (AED)CollectionsSECTION CPAGE Nr. CH/C/3PAGE Nr. CH/C/1PAGE Nr. CH/C/2carried to part summary(AED)MASONRY WORKSSECTION DPAGE Nr. CH/D/1The masonry work shall include fire stop and treatment around services penetration and like through wall and slab as per Engineers requirements.Concrete hollow blocks bedded jointed and pointed in bed mortar including necessary stiffeners and to the Engineers satisfaction.A200mm thick block wallM2700B100mm thick block wallM2391carried to part summary (AED)METAL WORKSSECTION EPAGE Nr. CH/E/1Rates for all attached loos, connections, welding, cleats, brackets and all necessary fixing accessories shall deemed to have included in the rates of structural metalwork's.Structural metal worksASupply, fabricate and installation of steel structures, connection plates, clip angles, connection bolts, anchor bolts and necessary secondary members complete to the engineers satisfactionTon500Non structural metal worksSand trap LouversBSize:- 15340mm x 3490mmNr6CSize:- 5340mm x 2490mmNr6DSupply and install steel cat laddersNr4Metal Sheet roofingSupply and install steel sheeting in composite insulated panel comprising 0.7mm gauge outer sheet with 45/250 trapezoidal profile with two coats semi glass-1 PVF2 finish,50mm thick factory injected rigid closed cell polyurethane foam and 0.4mm gauge polyester finish inner galvanized steel sheet.ERoofingM23919FEnclosureM23326Rain water gutterSupply and install rain water gutters in accordance with drawings and specifications.Size 400mm width x 500mm depthM265carried to part summary (AED)WOOD WORKSSECTION FPAGE Nr. CH/F/1Pantry Cabinetspantry base unit including concrete base ,granite top,shelves,hardwares and all necessary accessories.ASize 4100length, 850 height, 600mm widthSet1Top hung units including shelf,hardwares and all accessories material as per drawing,BSize 4100length, 850 height, 350mm widthSet1carried to part summary (AED)THERMAL AND MOISTURE PROTECTIONSECTION GPAGE Nr. CH/G/150mm thick protection screedABelow pile capsM248BBelow Ground slab, Trench pits, underground pitM24470CBelow water tankM2280DCompressed air stationM238Supply & laying 1000 gauge polythene sheet.EBelow pile capsM248FBelow Ground slab, Trench pits, underground pitM24470GBelow water tankM2280HCompressed air stationM238Waterproofing treatment to top of pileI700 mm diameter pilesNr34J500mm diameter pilesNr65Supply and laying of 4mm thick waterproofing membrane system with hot torch double layer including protection board.Vertical sidesKPile capsM2138LTrench pits, underground pitM2524MSides of water tanksM283Supply and laying of 4mm thick waterproofing membrane system with hot torch.NBelow Ground slab, Trench pits, underground pitM24470OBelow Pile CapsM248PBelow water tankM2280QCompressed air stationM238Supply and apply waterproofing liquid applied flexible cementitious waterproofing system including all related worksRWet areas such as toilet, pantryM238carried to part summary (AED)DOOR AND WINDOWSSECTION HPAGE Nr. CH/H/1Timber doorsTimber doorset comprising factory finish door frames architraves material as per finished schedules including fixing to concrete or block wall including ironmongeryASingle leaf hinged wooden door type DW01 1100mm width and 2200mm height 2hrs fire rated.Nr13BSingle leaf hinged wooden door type DW02: 900mm width and 2200mm height non fire rated.Nr2CSingle leaf hinged wooden door type DW03: 900mm width and 2200mm height 1hrs fire rated.Nr2Steel doorsSteel door set comprising factory finish (powder coated) door frames architraves material as per finished schedules including fixing to concrete or block wall including ironmongery.DDouble leaf hinged steel door type DS01 1800mm width and 2200mm height.Nr1ESingle leaf hinged steel door type DS02 1000mm width and 2200mm height.Nr6Aluminium DoorsAluminium door set comprising factory finish (powder coated) aluminium door frames, material as per finished schedules including fixing to concrete or block wall including ironmongery.FDouble leaf hinged aluminium door type DA01: 2000mm width and 2200mm height.Nr1To collections (AED)DOOR AND WINDOWS (Continued.)SECTION HPAGE Nr. CH/H/2Roller shuttersSupply and installation of Rockwool in filled hot dipped galvanised steel roller shutter door with motor and powder coated mild steel shutter box with door frame, with safety barriers and all necessary fittings as per drawing.ASize (9500mm width, 5850mm height)Nr1BSize (9300mm width, 5850mm height)Nr2CSize (5000mm width, 3150mm height)Nr1WindowsTilted doubled glazed aluminium windowsDTilted doubled glazed thermally broken aluminium window unit vertically sealed Type AW01. 1000mm width and 600mm heightNr10Glazingskylight glassESize (1700mm length, 1000mm width)Nr80Tinted GlassingFSize (1725mm length, 2200mm width)Nr2GSize (2900mm length, 2200mm width)Nr18HSize (3110mm length, 2200mm width)Nr34ISize (2740mm length, 2200mm width)Nr2JSize (2700mm length, 2200mm width)Nr2To collections (AED)CollectionsSECTION HPAGE Nr. CH/H/3PAGE Nr. CH/H/1PAGE Nr. CH/H/2carried to part summary(AED)FINISHESSECTION JPAGE Nr. CH/J/1Floor Finishes50mm thick cement sand screed to hard and smooth surface for offices onlyAunder porcelain tileM2433Bunder ceramic tilesM238Cunder epoxy coatingM23890Epoxy coatingDTo FloorM23890ETo wallsM2641Supply and lay porcelain floor tiles size (600x600) for officesFPorcelain tilesM2433Supply and lay ceramic tiles(600mmx600mm)jointed with approved adhesive and lay to approved pattern to Engineers satisfaction.GCeramic tilesM238SkirtingPorcelain tile skirting including jointing, pointing complete to the Engineers satisfactionH70mm HighM335Epoxy coating skirting complete to the Engineers satisfactionI100mm HighM79Plaster on walls20mm thick cement sand plaster on block or concrete wall to include plaster stop beads etc completeJTo receive washable emulsion paintM21085KTo receive epoxy paintM2641LTo receive Ceramic wall tilesM2226Supply and apply washable emulsion paint to plaster surface including all preparations complete to the Engineers satisfaction.MWashable emulsion paintM21085Supply and apply Epoxy paint to plaster surface including all preparations complete to the Engineers satisfaction.NEpoxy coating on wallsM2641Supply and lay ceramic tiles(600mmx600mm)jointed with approved adhesive and lay to approved pattern to Engineers satisfaction.OCeramic tilesM2226To collections (AED)FINISHES (Continue,,,)SECTION JPAGE Nr. CH/J/2Ceiling Finishes for officesSupply and install 600x600mm Gypsum tiles ceiling with gypsum board border complete with all necessary fittingsA600x600 gypsum with gypsum board borderM2433Supply and install 600x600mm waterproofing Gypsum tiles ceiling with waterproofing gypsum board border complete with all necessary fittingsB600x600 waterproofing gypsum tiles with waterproofing gypsum board borderM238Cement plaster to soffitCTo receive epoxy paintM2159Supply and apply Epoxy paint to ceiling including all necessary preparation and to The Engineers satisfactionDType C04 ceilingM2159To collections (AED)CollectionsSECTION JPAGE Nr. CH/J/3PAGE Nr. CH/J/1PAGE Nr. CH/J/2carried to part summary(AED)ACCESSORIESSECTION KPAGE Nr. CH/K/1MirrorsA6mm thick 600x1050mm clear mirror with marine plywood backing and stainless steel frame including all necessary fittings.etcNr4Vanity countersBsupply and installation of 30mm thick 300mm wide vanity counter with facial & backsplash including all necessary fittings.etcM5Csupply and installation of 30mm thick removable polished granite shelf at 850mm aboveFFL. (Avg.size 900x150) with all necessary fittings.Set3Supply and installation of toilet cubicles complete with door, partitions,ironmongry etc.DSize 2500x1800x2000ht with 2 partitions and 3 door.Set1ESupply and installation of PVC curtain with stainless steel hanging rod.Set2WardrobeFSupply and installation of 18mm thick MDF Pvc rapped wardrobe with stainless steel number plate & lock and all necessary fittings and accessories as shown on drawing. Size 1860x600x1800mm height.Set1carried to part summary(AED)PART SUMMARYSECTION SUMPAGE Nr. CH/SUM/1SITE WORKPAGE Nr.CH/B/1CONCRETE WORKSPAGE Nr. CH/C/3MASONRY WORKSPAGE Nr. CH/D/1METAL WORKSPAGE Nr. CH/E/1WOOD WORKSPAGE Nr. CH/F/1THERMAL AND MOISTURE PROTECTIONPAGE Nr. CH/G/1DOOR AND WINDOWSPAGE Nr. CH/H/3FINISHESPAGE Nr. CH/J/3ACCESSORIESPAGE Nr. CH/K/1Total amount carried to General summary(AED)

MWTaweelah Aluminium Extrusion Company LLCAluminium Extrusion Plant KIZAD Zone KP3Maintenance workshop Building (MW)Bill Of QuantitiesITEMITEM DESCRIPTIONUNITQUANTITYUNIT RATEAMOUNT IN UAE DhsSITE WORKSECTION BPAGE Nr.MW/B/1The contractor is required to have visited the site and fully understand the existing site conditions. The contractor is deem to have verified the extent of work and the work to be demolished. The contractor to verify with the engineer on any discripensies.No claim is allowed for contractor failure in verification of information and data and whatsoever on existing site conditions.ASite ClearanceM22690Excavation, cutting & levelling up to certain depth shown on drawings including safety consideration.BFoundations and over site excavationM3Rates onlyDisposalCLoading, transportation and disposal of unsuitable and surplus excavated material to designated place as directed by the Engineer.M3Rates onlyBackfillingDBackfilling, levelling and compaction for foundations with selected excavated material.M3Rates onlyFillingEFilling with specified material from outside, levelling and compaction.M35380Anti termite treatmentFGenerallyM22690Pile workReinforced cost in situe bored piles grade 60N/mm2 down to cut off level complete.G700mm dia bore piles maximum depth 13.0mNr14H500mm dia bore piles maximum depth 13.0mNr16Cutting of pile heads.Cutting of top of piles up to cut off level including chipping of concrete and exposing the rebar, cleaning to the engineer satisfaction.I700mm dia bore piles maximum depth 13.0mNr14J500mm dia bore piles maximum depth 13.0mNr16Pile testing.KAllow for testing of pile to the requirement.Item1Includedcarried to part summary (AED)CONCRETE WORKSSECTION CPAGE Nr. MW/C/1SUBSTRUCTURESBlinding concreteA50mm thick blinding concrete (Grade 20N/mm2) including supply of the curing material (hessian) clothes & polyethylene sheet), clear water for curing of the concreteM3135Reinforced concrete of grade 40N/mm2 with SRCBFor Pile CapsM321CTrenchesM357DFor Ground Slab 250mm thickM3706EConcrete pedestals of steel columnsM35High tensile steel including cutting, bending and placement.FFor Pile CapsTon3GTrenchesTon4HFor Ground Slab 250mm thickTon32IConcrete pedestals of steel columnsTon0.30ShutteringJVertical face of pile capeM289KSides of Ground slabM254LVertical sides of pedestalsM238MVertical sides of trench pitM2163NStone columns 1.5m c/c for soil strengtheningNr1581To collections (AED)MASONRY WORKSSECTION DPAGE Nr. MW/D/1The masonry work shall include fire stop and treatment around services penetration and like through wall and slab as per Engineers requirements.Concrete hollow blocks bedded jointed and pointed in bed mortar including necessary stiffeners and to the Engineers satisfaction.A400mm thickM2192B200mm thickM2504C100mm thickM278carried to part summary (AED)METAL WORKSSECTION EPAGE Nr. MW/E/1Rates for all attached loos, connections, welding, cleats, brackets and all necessary fixing accessories shall deemed to have included in the rates of structural metalwork's.Structural metal worksASupply, fabricate and installation of steel structures, connection plates, clip angles, connection bolts, anchor bolts and necessary secondary members complete to the engineers satisfactionTon233Non structural metal worksSand trap LouversBAt elevation-1M261CAt elevation-3M2133Metal Sheet roofingSupply and install steel sheeting in composite insulated panel comprising 0.7mm gauge outer sheet with 45/250 trapezoidal profile with two coats semi glass-1 PVF2 finish,50mm thick factory injected rigid closed cell polyurethane foam and 0.45mm gauge polyester finish inner galvanized steel sheet.DRoofingM22609EEnclosureM21762Rain water gutterSupply and install rain water gutters in accordance with drawings and specifications.Size 400mm width x 500mm depthM175carried to part summary (AED)WOOD WORKSSECTION FPAGE Nr. MW/F/1Pantry Cabinetspantry base unit including concrete base ,granite top,shelves,hardwares and all necessary accessories.ASize 4225length, 850 height, 600mm widthSet1Top hung units including shelf,hardwares and all accessories material as per drawing,BSize 4225length, 850 height, 350mm widthSet1carried to part summary (AED)THERMAL AND MOISTURE PROTECTIONSECTION GPAGE Nr. MW/G/150mm thick protection screedABelow pile capsM226BBelow Ground slab, trenchesM22690Supply & laying 1000 gauge polythene sheet.CBelow pile capsM226DBelow Ground slab, trenchesM22690Waterproofing treatment to top of pileE700 mm diameter pilesNr14F500mm diameter pilesNr16Supply and laying of 4mm thick waterproofing membrane system with hot torch double layer including protection board.Vertical sidesGPile capsM289HTrench pits, ground slabM282Supply and laying of 4mm thick waterproofing membrane system with hot torch.IBelow Ground slab, trenchesM22690JBelow Pile CapsM226Supply and apply waterproofing liquid applied flexible cementitious waterproofing system including all related worksKWet areas such as toilet, pantryM255carried to part summary (AED)DOOR AND WINDOWSSECTION HPAGE Nr. MW/H/1Steel door set comprising factory finish (powder coated) door frames architraves material as per finished schedules including fixing to concrete or block wall including ironmongery.ASingle leaf hinged steel door type DS01 1000mm width and 2150mm height.Nr7BSingle leaf hinged steel door type DS02 1000mm width and 2150mm height. Fire ratedNr5CSingle leaf hinged steel door type DS03 1000mm width and 2150mm height.Nr2DDouble leaf hinged steel door type DS04 1950mm width and 2150mm height.Nr1ESingle leaf hinged steel door type DS05 900mm width and 2150mm height .fire ratedNr1FSingle leaf hinged steel door type DS06 800mm width and 2150mm height.Nr1GSingle leaf hinged steel door type DS07 900mm width and 2150mm height. Fire ratedNr1Roller shuttersSupply and installation of Rockwool in filled hot dipped galvanised steel roller shutter door with motor and powder coated mild steel shutter box with door frame, with safety barriers and all necessary fittings as per drawing.HRS01 Size (4700mm width, 5850mm height)Nr3Tilted doubled glazed aluminium windowsITilted doubled glazed thermally broken aluminium window unit fixed Type AW01. 1000mm width and 600mm heightNr6.00JTilted doubled glazed thermally broken aluminium window unit one fixed on sliding Type AW02. 1000mm width and 600mm heightNr1.00KTilted doubled glazed thermally broken aluminium window fixed Type AW03. 3050mm width and 1200mm heightNr1.00Glazingskylight glassLSize (3700mm length, 1000mm width)Nr24carried to part summary (AED)FINISHESSECTION JPAGE Nr. MW/J/1Floor Finishes50mm thick cement sand screed to hard and smooth surface for offices onlyAunder porcelain tileM2150Bunder ceramic tilesM256Cunder epoxy coatingM22409Epoxy coatingDTo FloorM22409ETo wallsM2568Supply and lay porcelain floor tiles size (600x600) for officesFPorcelain tilesM2150Supply and lay ceramic tiles(600mmx600mm)jointed with approved adhesive and lay to approved pattern to Engineers satisfaction.GCeramic tilesM256SkirtingPorcelain tile skirting including jointing, pointing complete to the Engineers satisfactionH70mm HighM95Plaster on walls20mm thick cement sand plaster on block or concrete wall to include plaster stop beads etc completeITo receive washable emulsion paintM2348JTo receive epoxy paintM2568KTo receive Ceramic wall tilesM2246Supply and apply washable emulsion paint to plaster surface including all preparations complete to the Engineers satisfaction.LWashable emulsion paintM2348Supply and lay ceramic tiles(600mmx600mm)jointed with approved adhesive and lay to approved pattern to Engineers satisfaction.MCeramic tilesM2246To collections (AED)FINISHES (Continue,,,)SECTION JPAGE Nr. MW/J/2Ceiling Finishes for officesSupply and install 600x600mm Gypsum tiles ceiling with gypsum board border complete with all necessary fittingsA600x600 gypsum with gypsum board borderM2115Supply and install 600x600mm waterproofing Gypsum tiles ceiling with waterproofing gypsum board border complete with all necessary fittingsB600x600 waterproofing gypsum tiles with waterproofing gypsum board borderM255To collections (AED)CollectionsSECTIONJPAGE Nr. MW/J/3PAGE Nr. MW/J/1PAGE Nr. MW/J/2carried to part summary(AED)ACCESSORIESSECTION KPAGE Nr. MW/K/1MirrorsA6mm thick 600x1000mm clear mirror with marine plywood backing and stainless steel frame including all necessary fittings.etcNr2Vanity countersBsupply and installation of 30mm thick 300mm wide vanity counter with facial & backsplash including all necessary fittings.etcM4Csupply and installation of 30mm thick removable polished granite shelf at 850mm aboveFFL. (Avg.size 900x150) with all necessary fittings.Set2Supply and installation of toilet cubicles complete with door, partitions,ironmongry etc.DSize 2075x1800x2000ht with 1 partitions and 2 door.Set2Esupply and installation of 30mm thick polished granite shelf shoe rake ( size 900x475widthx1200mm height)Set1Fsupply and installation of 30mm thick polished granite step with stainless steel fixed stool Grade 316(3mm thick mirror finish) with all accessories.Set1To collections (AED)PART SUMMARYSECTION SUMPAGE Nr. MW/SUM/1SITE WORKPAGE Nr.MW/B/1CONCRETE WORKSPAGE Nr. MW/C/1MASONRY WORKSPAGE Nr. MW/D/1METAL WORKSPAGE Nr. MW/E/1WOOD WORKSPAGE Nr. MW/F/1THERMAL AND MOISTURE PROTECTIONPAGE Nr. MW/G/1DOOR AND WINDOWSPAGE Nr. MW/H/1FINISHESPAGE Nr. MW/J/3ACCESSORIESPAGE Nr. MW/K/1Total amount carried to General summary(AED)

VGTaweelah Aluminium Extrusion Company LLCAluminium Extrusion Plant KIZAD Zone KP3Visitor Gate Building (VG)Bill Of QuantitiesITEMITEM DESCRIPTIONUNITQUANTITYUNIT RATEAMOUNT IN UAE DhsSITE WORKSECTION BPAGE Nr.EB/B/1The contractor is required to have visited the site and fully understand the existing site conditions. The contractor is deem to have verified the extent of work and the work to be demolished. The contractor to verify with the engineer on any discripensies.No claim is allowed for contractor failure in verification of information and data and whatsoever on existing site conditions.ASite ClearanceM275Excavation, cutting & levelling up to certain depth shown on drawings including safety consideration.BFoundations and over site excavationM3Rates onlyDisposalCLoading, transportation and disposal of unsuitable and surplus excavated material to designated place as directed by the Engineer.M3Rates onlyBackfillingDBackfilling, levelling and compaction for foundations with selected excavated material.M3Rates onlyFillingEFilling with specified material from outside, levelling and compaction.M3146Anti termite treatmentFGenerallyM275carried to part summary (AED)CONCRETE WORKSSECTION CPAGE Nr. VG/C/1SUBSTRUCTURESBlinding concreteA50mm thick blinding concrete (Grade 20N/mm2) including supply of the curing material (hessian) clothes & polyethylene sheet), clear water for curing of the concreteM34Reinforced concrete of grade 40N/mm2BFor Ground Slab 300mm thickM327High tensile steel including cutting, bending and placement.CFor Ground Slab 300mm thickTon1.5ShutteringDSides of Ground slabM211EStone columns 1.9m c/c for soil strengtheningNr67To collections (AED)CONCRETE WORKS (continued.)SECTION CPAGE Nr. VG/C/2SUPER STRUCTURESReinforced concrete of grade 40N/mm2AColumnsM32.75BRoof slabM327.0CParapetM34.0High tensile steel including cutting, bending and placement.DColumnsTon0.40ERoof slabTon4.00FParapetTon0.60ShutteringGColumnsM236HRoof slabM290IParapetM231To collections (AED)CollectionsSECTION CPAGE Nr. VG/C/3PAGE Nr. VG/C/1PAGE Nr. VG/C/2carried to part summary(AED)MASONRY WORKSSECTION DPAGE Nr. VG/D/1The masonry work shall include fire stop and treatment around services penetration and like through wall and slab as per Engineers requirements.Concrete hollow blocks bedded jointed and pointed in bed mortar including necessary stiffeners and to the Engineers satisfaction.A300mm thick block workM241B200mm thick block workM257C100mm thick block workM233carried to part summary (AED)METAL WORKSSECTION EPAGE Nr. VG/E/1Non structural metal worksAluminium claddingASupply and installation of aluminium claddingM295Double glazed curtain wallBSupply and installation of double glazed curtain wallM261.0Aluminium louversCM232EFcarried to part summary (AED)WOOD WORKSSECTION FPAGE Nr. VG/F/1Pantry Cabinetspantry base unit including concrete base ,granite top,shelves,hardwares and all necessary accessories.ASize 2800length, 850 height, 600mm widthSet1Top hung units including shelf,hardwares and all accessories material as per drawing,BSize 2800length, 850 height, 350mm widthSet1carried to part summary (AED)THERMAL AND MOISTURE PROTECTIONSECTION GPAGE Nr. VG/G/150mm thick protection screedABelow Ground slabM275Supply & laying 1000 gauge polythene sheet.BBelow Ground slabM275Supply and laying of 4mm thick waterproofing membrane system with hot torch.CBelow Ground slabM275Supply and apply waterproofing liquid applied flexible cementitious waterproofing system including all related worksDWet areas such as pantryM299Supply and laying of roof waterproofing system comprising of 45mm thick polyurethane foam with 48KG/m3 density, one layer polytex liquid U.V protection coat, one layer of 13mm polyfab filter material.EFor roof slabM282F200mm high upturn under skirtingM2880mm thick protection concrete screed to receive roof tiles.GUnder Terrazzo TilesM282carried to part summary (AED)DOOR AND WINDOWSSECTION HPAGE Nr. VG/H/1Timber doorsTimber door set comprising factory finish door frames architraves material as per finished schedules including fixing to concrete or block wall including ironmongeryASingle leaf hinged wooden door type DW01 1000mm width and 2200mm height 1hrs fire rated.Nr1BSingle leaf hinged wooden door type DW02: 900mm width and 2200mm height non fire rated.Nr3Steel doorsSteel door set comprising factory finish (powder coated) door frames architraves material as per finished schedules including fixing to concrete or block wall including ironmongery.CDouble leaf hinged steel door type DS01 1000mm width and 2200mm height. 1hrs fire rated.Nr1carried to part summary (AED)FINISHESSECTION JPAGE Nr. VG/J/1Floor Finishes50mm thick cement sand screed to hard and smooth surface for offices onlyAunder porcelain tileM236Bunder ceramic tilesM213Epoxy coatingCTo wallsM236DTo ceilingM27Supply and lay porcelain floor tiles size (600x600) for officesEPorcelain tilesM236Supply and lay ceramic tiles(600mmx600mm)jointed with approved adhesive and lay to approved pattern to Engineers satisfaction.FCeramic tilesM213Supply and installation of metallic raised floor with anti static vinyl tilesGTele.room (F11)M27Supply and lay 28mm thick Terrazzo tiles (300mmx300mm)jointed with approved adhesive and lay to approved pattern to Engineers satisfaction.HTerrazzo tilesM282SkirtingPorcelain tile skirting including jointing, pointing complete to the Engineers satisfactionI70mm HighM28Epoxy coating skirting complete to the Engineers satisfactionJ100mm HighM10Terrazzo tile skirting including jointing, pointing complete to the Engineers satisfactionK200mm High at roofM39Plaster on walls20mm thick cement sand plaster on block or concrete wall to include plaster stop beads etc completeLTo receive washable emulsion paintM2108MTo receive epoxy paintM236NTo receive Ceramic wall tilesM287To collections (AED)FINISHES (Continue,,,)SECTION JPAGE Nr. VG/J/2Supply and apply washable emulsion paint to plaster surface including all preparations complete to the Engineers satisfaction.AWashable emulsion paintM2108Supply and lay ceramic tiles(600mmx600mm)jointed with approved adhesive and lay to approved pattern to Engineers satisfaction.BCeramic tilesM286Ceiling FinishesSupply and install 600x600mm Gypsum tiles ceiling with gypsum board border complete with all necessary fittingsC600x600 gypsum with gypsum board borderM236Supply and install 600x600mm waterproofing Gypsum tiles ceiling with waterproofing gypsum board border complete with all necessary fittingsD600x600 waterproofing gypsum tiles with waterproofing gypsum board borderM213Cement plaster to soffitETo receive epoxy paintM27To collections (AED)CollectionsSECTION JPAGE Nr. VG/J/3PAGE Nr. VG/J/1PAGE Nr. VG/J/2carried to part summary(AED)ACCESSORIESSECTION KPAGE Nr. VG/K/1MirrorsA6mm thick 600x1050mm clear mirror with marine plywood backing and stainless steel frame including all necessary fittings.etcNr2Vanity countersBsupply and installation of 30mm thick 300mm wide vanity counter with facial & backsplash including all necessary fittings.etcM3Csupply and installation of 30mm thick removable polished granite shelf at 850mm aboveFFL. (Avg.size 900x150) with all necessary fittings.Set2carried to part summary(AED)PART SUMMARYSECTION SUMPAGE Nr. VG/SUM/1SITE WORKPAGE Nr.EB/B/1CONCRETE WORKSPAGE Nr. VG/C/3MASONRY WORKSPAGE Nr. VG/D/1METAL WORKSPAGE Nr. VG/E/1WOOD WORKSPAGE Nr. VG/F/1THERMAL AND MOISTURE PROTECTIONPAGE Nr. VG/G/1DOOR AND WINDOWSPAGE Nr. VG/H/1FINISHESPAGE Nr. VG/J/3ACCESSORIESPAGE Nr. VG/K/1Total amount carried to General summary(AED)

DGTaweelah Aluminium Extrusion Company LLCAluminium Extrusion Plant KIZAD Zone KP3Delivery Gate Building (DG)Bill Of QuantitiesITEMITEM DESCRIPTIONUNITQUANTITYUNIT RATEAMOUNT IN UAE DhsSITE WORKSECTION BPAGE Nr.DG/B/1The contractor is required to have visited the site and fully understand the existing site conditions. The contractor is deem to have verified the extent of work and the work to be demolished. The contractor to verify with the engineer on any discripensies.No claim is allowed for contractor failure in verification of information and data and whatsoever on existing site conditions.ASite ClearanceM235Excavation, cutting & levelling up to certain depth shown on drawings including safety consideration.BFoundations and over site excavationM3Rates onlyDisposalCLoading, transportation and disposal of unsuitable and surplus excavated material to designated place as directed by the Engineer.M3Rates onlyBackfillingDBackfilling, levelling and compaction for foundations with selected excavated material.M3Rates onlyFillingEFilling with specified material from outside, levelling and compaction.M370Anti termite treatmentFGenerallyM235carried to part summary (AED)CONCRETE WORKSSECTION CPAGE Nr. DG/C/1SUBSTRUCTURESBlinding concreteA50mm thick blinding concrete (Grade 20N/mm2) including supply of the curing material (hessian) clothes & polyethylene sheet), clear water for curing of the concreteM32Reinforced concrete of grade 40N/mm2BFor Ground Slab 250mm thickM314High tensile steel including cutting, bending and placement.CFor Ground Slab 250mm thickTon0.8ShutteringCSides of Ground slabM28DStone columns 1.9m c/c for soil strengtheningNr38To collections (AED)CONCRETE WORKS (continued.)SECTION CPAGE Nr. DG/C/2SUPER STRUCTURESReinforced concrete of grade 40N/mm2AColumnsM32BRoof slabM312.0CParapetM32.8High tensile steel including cutting, bending and placement.DColumnsTon0.29ERoof slabTon1.75FParapetTon0.40ShutteringGColumnsM220HRoof slabM234IParapetM222To collections (AED)CollectionsSECTION CPAGE Nr. DG/C/3PAGE Nr. DG/C/1PAGE Nr. DG/C/2carried to part summary(AED)MASONRY WORKSSECTION DPAGE Nr. DG/D/1The masonry work shall include fire stop and treatment around services penetration and like through wall and slab as per Engineers requirements.Concrete hollow blocks bedded jointed and pointed in bed mortar including necessary stiffeners and to the Engineers satisfaction.A200mm thick block workM259B100mm thick block workM24carried to part summary (AED)METAL WORKSSECTION EPAGE Nr. DG/E/1Non structural metal worksAluminium claddingASupply and installation of aluminium claddingM287Double glazed curtain wallBSupply and installation of double glazed curtain wallM243.0Aluminium louversCM221carried to part summary (AED)THERMAL AND MOISTURE PROTECTIONSECTION GPAGE Nr. DG/G/150mm thick protection screedABelow Ground slabM235Supply & laying 1000 gauge polythene sheet.BBelow Ground slabM235Supply and laying of 4mm thick waterproofing membrane system with hot torch.CBelow Ground slabM235Supply and apply waterproofing liquid applied flexible cementitious waterproofing system including all related worksDWet areas such as toiletM239Supply and laying of roof waterproofing system comprising of 45mm thick polyurethane foam with 48KG/m3 density, one layer polytex liquid U.V protection coat, one layer of 13mm polyfab filter material.EFor roof slabM232F200mm high upturn under skirtingM2680mm thick protection concrete screed to receive roof tiles.GUnder Terrazzo TilesM232carried to part summary (AED)DOOR AND WINDOWSSECTION HPAGE Nr. DG/H/1Timber doorsTimber door set comprising factory finish door frames architraves material as per finished schedules including fixing to concrete or block wall including ironmongeryASingle leaf hinged wooden door type DW01 1000mm width and 2200mm height 1hrs fire rated.Nr2BSingle leaf hinged wooden door type DW02: 900mm width and 2200mm height non fire rated.Nr1Steel doorsSteel door set comprising factory finish (powder coated) door frames architraves material as per finished schedules including fixing to concrete or block wall including ironmongery.CSingle leaf hinged steel door type DS01 1000mm width and 2200mm hight.1hrs fire rated.Nr1carried to part summary (AED)FINISHESSECTION JPAGE Nr. DG/J/1Floor Finishes50mm thick cement sand screed to hard and smooth surface for offices onlyAunder porcelain tileM220Bunder ceramic tilesM23Epoxy coatingCTo wallsM227DTo ceilingM25Supply and lay porcelain floor tiles size (600x600) for officesEPorcelain tilesM220Supply and lay ceramic tiles(600mmx600mm)jointed with approved adhesive and lay to approved pattern to Engineers satisfaction.FCeramic tilesM23Supply and installation of metallic raised floor with anti static vinyl tilesGTele.room (F11)M25SkirtingPorcelain tile skirting including jointing, pointing complete to the Engineers satisfactionH70mm HighM26Epoxy coating skirting complete to the Engineers satisfactionI100mm HighM8Terrazzo tile skirting including jointing, pointing complete to the Engineers satisfactionJ200mm High at roofM27Plaster on walls20mm thick cement sand plaster on block or concrete wall to include plaster stop beads etc completeKTo receive washable emulsion paintM252LTo receive epoxy paintM227MTo receive Ceramic wall tilesM218Supply and apply washable emulsion paint to plaster surface including all preparations complete to the Engineers satisfaction.NWashable emulsion paintM252Supply and lay ceramic tiles(600mmx600mm)jointed with approved adhesive and lay to approved pattern to Engineers satisfaction.OCeramic tilesM218To collections (AED)FINISHES (Continue,,,)SECTION JPAGE Nr. DG/J/2Ceiling FinishesSupply and install 600x600mm Gypsum tiles ceiling with gypsum board border complete with all necessary fittingsA600x600 gypsum with gypsum board borderM220Supply and install 600x600mm waterproofing Gypsum tiles ceiling with waterproofing gypsum board border complete with all necessary fittingsB600x600 waterproofing gypsum tiles with waterproofing gypsum board borderM23Cement plaster to soffitCTo receive epoxy paintM25To collections (AED)CollectionsSECTION JPAGE Nr. DG/J/3PAGE Nr. DG/J/1PAGE Nr. DG/J/2carried to part summary(AED)ACCESSORIESSECTION KPAGE Nr. DG/K/1MirrorsA6mm thick 600x1200mm clear mirror with marine plywood backing and stainless steel frame including all necessary fittings.etcNr1Vanity countersBsupply and installation of 30mm thick 300mm wide vanity counter with facial & backsplash including all necessary fittings.etcM2Csupply and installation of 30mm thick removable polished granite shelf at 850mm above. (Avg.size 900x150) with all necessary fittings.Set1To collections (AED)PART SUMMARYSECTION SUMPAGE Nr. DG/SUM/1SITE WORKPAGE Nr.DG/B/1CONCRETE WORKSPAGE Nr. DG/C/3MASONRY WORKSPAGE Nr. DG/D/1METAL WORKSPAGE Nr. DG/E/1THERMAL AND MOISTURE PROTECTIONPAGE Nr. DG/G/1DOOR AND WINDOWSPAGE Nr. DG/H/1FINISHESPAGE Nr. DG/J/3ACCESSORIESPAGE Nr. DG/K/1Total amount carried to General summary(AED)

T&RTaweelah Aluminium Extrusion Company LLCAluminium Extrusion Plant KIZAD Zone KP3Training & Recreational Building (TR)Bill Of QuantitiesITEMITEM DESCRIPTIONUNITQUANTITYUNIT RATEAMOUNT IN UAE DhsSITE WORKSECTION BPAGE Nr.TR/B/1The contractor is required to have visited the site and fully understand the existing site conditions. The contractor is deem to have verified the extent of work and the work to be demolished. The contractor to verify with the engineer on any discripensies.No claim is allowed for contractor failure in verification of information and data and whatsoever on existing site conditions.ASite ClearanceM2425Excavation, cutting & levelling up to certain depth shown on drawings including safety consideration.BFoundations and over site excavationM3Rates onlyDisposalCLoading, transportation and disposal of unsuitable and surplus excavated material to designated place as directed by the Engineer.M3Rates onlyBackfillingDBackfilling, levelling and compaction for foundations with selected excavated material.M3Rates onlyFillingEFilling with specified material from outside, levelling and compaction.M3850Anti termite treatmentFGenerallyM2425Pile workReinforced cost in situe bored piles grade 60N/mm2 down to cut off level complete.G700mm dia bore piles maximum depth 13.0mNr10H500mm dia bore piles maximum depth 13.0mNr9Cutting of pile heads.Cutting of top of piles up to cut off level including chipping of concrete and exposing the rebar, cleaning to the engineer satisfaction.I700mm dia bore piles maximum depth 13.0mNr10J500mm dia bore piles maximum depth 13.0mNr9Pile testing.KAllow for testing of pile to the requirement.Item1Includedcarried to part summary (AED)CONCRETE WORKSSECTION CPAGE Nr. TR/C/1SUBSTRUCTURESBlinding concreteA50mm thick blinding concrete (Grade 20N/mm2) including supply of the curing material (hessian) clothes & polyethylene sheet), clear water for curing of the concreteM321Reinforced concrete of grade 40N/mm2 with SRCBFor Pile CapsM316CTie beamsM328DFor Ground Slab 250mm thickM3111High tensile steel including cutting, bending and placement.EFor Pile CapsTon2.3FTie beamsTon3.9GFor Ground Slab 250mm thickTon15.5HShutteringIVertical face of pile capeM265JSides of Ground slabM219KTie beamsM2111To collections (AED)CONCRETE WORKS (continued.)SECTION CPAGE Nr. TR/C/2SUPER STRUCTURESReinforced concrete of grade 40N/mm2AColumnsM320B1st floor slabM3104CSuspended beams 1st floorM326D1st floor up standM36.5ERoof slabM343.0Froof beamsM320.2GParapetM34.5High tensile steel including cutting, bending and placement.HColumnsTon2.80I1st floor slabTon14.56JSuspended beams 1st floorTon3.60K1st floor up standTon0.90LRoof slabTon6.00Mroof beamsTon2.83NParapetTon0.63ShutteringOColumnsM2177P1st floor slabM2407QSuspended beams 1st floorM2188R1st floor up standM251SRoof slabM2172Troof beamsM2112UParapetM238To collections (AED)CollectionsSECTION CPAGE Nr. TR/C/3PAGE Nr. TR/C/1PAGE Nr. TR/C/2carried to part summary(AED)MASONRY WORKSSECTION DPAGE Nr. TR/D/1The masonry work shall include fire stop and treatment around services penetration and like through wall and slab as per Engineers requirements.Concrete hollow blocks bedded jointed and pointed in bed mortar including necessary stiffeners and to the Engineers satisfaction.A600mm thick block wallM234B300mm thick block wallM236C250mm thick block wallM2198D200mm thick block wallM2434E100mm thick block wallM2118carried to part summary (AED)METAL WORKSSECTION EPAGE Nr. TR/E/1Rates for all attached loos, connections, welding, cleats, brackets and all necessary fixing accessories shall deemed to have included in the rates of structural metalwork's.Structural metal worksASupply, fabricate and installation of steel structures, connection plates, clip angles, connection bolts, anchor bolts and necessary secondary members complete to the engineers satisfactionTon5Non structural metal worksAluminium claddingBSupply and installation of aluminium claddingM2445Double glazed curtain wallCSupply and installation of double glazed curtain wallM2160Aluminium louversDM2100HandrailEPowder coated aluminium handrail for stair caseM8Cat ladderG.I steel cat ladder with safety Cage (500mm wide)FGround floor to lower roof5GLower roof to upper roof4carried to part summary (AED)WOOD WORKSSECTION FPAGE Nr. TR/F/1Pantry Cabinetspantry base unit including concrete base ,granite top,shelves,hardwares and all necessary accessories.ASize 3600length, 850 height, 600mm widthSet1Top hung units including shelf,hardwares and all accessories material as per drawing,ESize 3600length, 850 height, 350mm widthSet1Reception CounterCounter Base unit including shelves, hardware and all accessoriesCSize 9500mm lengthx770mm hightx500mm wide.Set1carried to part summary (AED)THERMAL AND MOISTURE PROTECTIONSECTION GPAGE Nr. TR/G/150mm thick protection screedABelow pile capsM218BBelow Ground slabM2425Supply & laying 1000 gauge polythene sheet.CBelow pile capsM218DBelow Ground slabM2425Waterproofing treatment to top of pileE700 mm diameter pilesNr10F500mm diameter pilesNr9Supply and laying of 4mm thick waterproofing membrane system with hot torch double layer including protection board.Vertical sidesGPile capsM265Htop of pile capsM218IGround beamsM2111Supply and laying of 4mm thick waterproofing membrane system with hot torch.JBelow Ground slabM2425KBelow Pile CapsM218Supply and apply waterproofing liquid applied flexible cementitious waterproofing system including all related worksLWet areas such as toilet, pantryM2567Supply and laying of roof waterproofing system comprising of 45mm thick polyurethane foam with 48KG/m3 density, one layer polytex liquid U.V protection coat, one layer of 13mm polyfab filter material.MFor roof slabM2422N200mm high upturn under skirtingM22680mm thick protection concrete screed to receive roof tiles.OUnder Terrazzo TilesM2422carried to part summary (AED)DOOR AND WINDOWSSECTION HPAGE Nr. TR/H/1Timber doorsTimber door set comprising factory finish door frames architraves material as per finished schedules including fixing to concrete or block wall including ironmongeryASingle leaf hinged wooden door type DW01 1100mm width and 2200mm height 2hrs fire rated.Nr1BSingle leaf hinged wooden door type DW02: 1100mm width and 2200mm height non fire rated.Nr5CSingle leaf hinged wooden door type DW03: 1000mm width and 2200mm height 1hrs fire rated.Nr2DSingle leaf hinged wooden door type DW04: 1000mm width and 2200mm height non fire rated.Nr3ESingle leaf hinged wooden door type DW05:800mm width and 2200mm height 1hrs fire rated.Nr1FSingle leaf hinged wooden door type DW06: 900mm width and 2200mm height 1hrs fire rated.Nr2Steel doorsSteel door set comprising factory finish (powder coated) door frames architraves material as per finished schedules including fixing to concrete or block wall including ironmongery.GSingle leaf hinged steel door type DS02 1000mm width and 2200mm height.Nr1Aluminium DoorsAluminium door set comprising factory finish (powder coated) aluminium door frames, material as per finished schedules including fixing to concrete or block wall including ironmongery.HDouble leaf hinged aluminium door type DA01: 1500mm width and 2200mm height.Nr1Glass door set comprising factory finish (hairline) stainless steel door frames, material as per finished schedules including fixing to concrete or block wall including ironmongery.ISingle leaf hinged glass door type DG01: 1200mm width and 2200mm heightNr4To collections (AED)FINISHESSECTION JPAGE Nr. TR/J/1Floor Finishes50mm thick cement sand screed to hard and smooth surface for offices onlyAunder porcelain tileM2154Bunder ceramic tilesM2133Cunder epoxy coatingM27Epoxy coatingDTo FloorM27ETo wallsM2124FTo CeilingM232Supply and lay porcelain floor tiles size (600x600) for officesGPorcelain tiles ( Base price AED/M2)M2154Supply and lay ceramic tiles(600mmx600mm)jointed with approved adhesive and lay to approved pattern to Engineers satisfaction.HCeramic tiles ( Base price AED/M2)M2133Supply and lay Granite tiles(600mmx600mm)jointed with approved adhesive and lay to approved pattern to Engineers satisfaction.IGranite tiles ( Base price AED/M2)M229Supply and lay 28mm thick Terrazzo tiles (300mmx300mm)jointed with approved adhesive and lay to approved pattern to Engineers satisfaction.JTerrazzo tiles ( Base price AED/M2)M2422Supply and installation of 43mm thick high density rubber on smooth concrete surface including all preparations complete.KReception/gym/table tennis court type F09M2189SkirtingPorcelain tile skirting including jointing, pointing complete to the Engineers satisfactionL70mm HighM106Epoxy coating skirting complete to the Engineers satisfactionM100mm HighM10Ceramic tile skirting including jointing, pointing complete to the Engineers satisfactionN70mm HighM26To collections (AED)FINISHES (Continue,,,)SECTION JPAGE Nr. TR/J/2Terrazzo tile skirting including jointing, pointing complete to the Engineers satisfactionA200mm HighM131Granite tile skirting including jointing, pointing complete to the Engineers satisfactionB70mm HighM47Supply and installation of PVC skirting including jointing complete to the engineer satisfactionCReception/gym/table tennis court type SK05M101Wall finishesPlaster on walls20mm thick cement sand plaster on block or concrete wall to include plaster stop beads etc completeDTo receive washable emulsion paintM2732ETo receive epoxy paintM2124FTo receive Ceramic wall tilesM2434Supply and lay ceramic tiles(600mmx600mm)jointed with approved adhesive and lay to approved pattern to Engineers satisfaction.GCeramic tiles ( Base price AED/M2)M2