Calcul Hilti Ancore

Embed Size (px)

Citation preview

  • 8/10/2019 Calcul Hilti Ancore

    1/15

    Seismic Academy I Bologna 8 Novembre 2013 | J. Gramaxo 1www.hilti.it/sismico

    Hilti Seismic Academy

    Jorge Gramaxo

    Technical Marketing

    Hilti AG

    Design of Anchors in Seismic Regions as perthe New European Guideline EOTA TR045

  • 8/10/2019 Calcul Hilti Ancore

    2/15

    Seismic Academy I Bologna 8 Novembre 2013 | J. Gramaxo 2www.hilti.it/sismico

    When cracks form in concrete, there is a high chance that they will

    intersect the anchor location considering:

    Anchors are expected to be located in concrete

    cracks during an earthquake

    stresses from the pre-stressingor loading of the anchor stress concentration caused bythe anchor hole (notch effect)

    Source: Prof. Rolf Eligehausen , University of Stuttgart: tests to asses the likelihood of cracks intercepting the position of

    anchors and anchor holes

  • 8/10/2019 Calcul Hilti Ancore

    3/15

    Seismic Academy I Bologna 8 Novembre 2013 | J. Gramaxo 3www.hilti.it/sismico

    As a cracks intersect the anchor the load transfer will be changed due

    to an unsymmetrical distribution of the anchor loads

    The resistance of the anchors is highly affected by the width of the

    cracks and in case of earthquake loading can reach 0.8mm

    Concrete cracks lead to significant changes in

    the anchors load transfer and performance

    stress distribution in

    non-cracked concrete

    stress distribution in

    cracked concrete

    crack plane

  • 8/10/2019 Calcul Hilti Ancore

    4/15

    Seismic Academy I Bologna 8 Novembre 2013 | J. Gramaxo 4www.hilti.it/sismico

    During an earthquake the anchors will be need to cope with:

    Seismic loading induces extreme conditions in

    the fastenings, much above concrete cracks

    Shear

    Tensio

    nCrackwidth

    Load cycling Concrete crack cycling

    w/ larger crack width

    Anchor design for seismic loading requires a set of specific

    prequalification, approval document and design regulations

  • 8/10/2019 Calcul Hilti Ancore

    5/15

    Seismic Academy I Bologna 8 Novembre 2013 | J. Gramaxo 5www.hilti.it/sismico

    Consistent with the new European assessment for anchors in seismic

    regions, ETAG 001 Annex E, and applicable for anchors which have

    been awarded an ETA in accordance to it.

    Has been developed during the revision of the CEN/TS 1992-4 seriesand complies with the final draft of EN 1992-4

    This document intends to guide the design of anchor for seismic

    loading bridging the time span until the publication of EN 1992-4

    EOTA TR045 represents current best practice

    for seismic design of anchors in Europe

    < 2013

    No EU regulation

    2013

    EOTA TR045

    2014 / 2015

    EN 1992-4

    European design method for anchors to resist seismic loading

  • 8/10/2019 Calcul Hilti Ancore

    6/15

    Seismic Academy I Bologna 8 Novembre 2013 | J. Gramaxo 6www.hilti.it/sismico

    b Ductile anchor

    anchors must fulfill the ductility requirements and

    steel failure must govern the anchor resistance

    To ensure ductile behavior of the connection

    3 different design approaches are offered

    a1 Capacity Design

    anchors must resist to the load corresponding to

    the yielding or failure of the attachment

    a2 Elastic design

    anchors must resist to the load resulting from an

    elastic seismic design

  • 8/10/2019 Calcul Hilti Ancore

    7/15Seismic Academy I Bologna 8 Novembre 2013 | J. Gramaxo 7www.hilti.it/sismico

    Pragmatic approach for calculating of seismic

    actions in non-structural elements

    As per Eurocode 8 can often be difficult to establish with confidence

    the fundamental vibration period Taof the non-structural element.

    Fa= Sa. Wa / qa

    EOTA TR045 to solve this issue provides:

    - expression from Eurocode 8 rearranged (equation 4.25, EN1998-1)

    - seismic amplification factor Aa per non-structural element

    - behavior factors qafor additional non-structural elements

    Waown weight of the element (KN)

  • 8/10/2019 Calcul Hilti Ancore

    8/15Seismic Academy I Bologna 8 Novembre 2013 | J. Gramaxo 8www.hilti.it/sismico

    Tension resistance to seismic loading for

    mechanical anchors

    TENSION

    Ref. values N0Rk,seis

    ETA values

    (C1 or C2)Calculated as perETAG 001 Annex C

    Steel N0Rk,s,seis -

    Pull-out N0Rk,p,seis -

    Concrete cone - N0Rk,c,seis

    NRk,seis= agap aseis N0Rk,seis

    aseis provided by the TR

    agap= 1.0 (no influence in tension)

    Nd,seis= Nk,seis / gM,seis gM,seisprovided by the ETA

  • 8/10/2019 Calcul Hilti Ancore

    9/15Seismic Academy I Bologna 8 Novembre 2013 | J. Gramaxo 9www.hilti.it/sismico

    Tension resistance to seismic loading for

    chemical anchors

    TENSION

    Ref. values N0Rk,seis

    ETA values

    (C1 or C2)Calculated as per

    EOTA TR029

    Steel N0Rk,s,seis -

    Combined pull-out and

    concrete cone tRk,seis N0

    Rk,p,seis

    Concrete cone - N0Rk,c,seis

    NRk,seis= agap aseis N0Rk,seis

    aseis provided by the TR

    agap= 1.0 (no influence in tension)

    Nd,seis= Nk,seis / gM,seis gM,seisprovided by the ETA

  • 8/10/2019 Calcul Hilti Ancore

    10/15Seismic Academy I Bologna 8 Novembre 2013 | J. Gramaxo 10www.hilti.it/sismico

    Shear resistance to seismic loading for

    mechanical and chemical anchors

    SHEAR

    Ref. values V0Rk,seis

    ETA values

    (C1 or C2)Calculated as per ETAG

    001 Annex C / TR029

    Steel V0Rk,s,seis -

    Pry-out - V0

    Rk,cp,seis

    Concrete edge breakout - V0Rk,c,seis

    VRk,seis= agap aseis V0Rk,seis

    aseis provided by the TR

    agap= 1.0 filled annular gap= 0.5 if annular gap is not filled

    Vd,seis= Vk,seis / gM,seis gM,seisprovided by the ETA

  • 8/10/2019 Calcul Hilti Ancore

    11/15Seismic Academy I Bologna 8 Novembre 2013 | J. Gramaxo 11www.hilti.it/sismico

    Presence of annular gaps between the anchors

    and the fixture reduces shear resistance to half

    The shear forces on the anchors are amplified in presence an

    annular gap due to a hammer effect on the anchor

    The factor gapattends to the overload resulting from annular gap

    between the anchor and the steel plate

    Design shear resistance x2 if it can be ensured no hole clearance

    between the anchor and the fixture. Hilti Dynamic Set ensures proper filling of the annular gap and as such

    ensures the an enhanced shear resistance under seismic loading

  • 8/10/2019 Calcul Hilti Ancore

    12/15

    Seismic Academy I Bologna 8 Novembre 2013 | J. Gramaxo 12www.hilti.it/sismico

    If deformations are relevant for the connection it shall be demonstrated

    that these deformations can be accommodated by the anchors

    Anchors awarded Seismic Performance Category C2 ETAs provide the

    anchors displacement for shear and tension If the required displacement is smaller than what the anchor displays,

    then the following reduction is applied to the design resistance

    Anchorage proof for the Damage Limitation

    State (DLS) is also considered in EOTA TR045

    dN,req (DLS)Defined by the designer ;

    Note: Expression for the correction of tension design resistance; shear is done in the same manner

    dN,seis (DLS)Provided in the relevant ETA

  • 8/10/2019 Calcul Hilti Ancore

    13/15

    Seismic Academy I Bologna 8 Novembre 2013 | J. Gramaxo 13www.hilti.it/sismico

    Summary of the seismic design procedure

    Selected anchors by their Seismic Performance Category (C1 or C2)

    according to the ground acceleration and building importance class

    Identify the ULS seismic loads according to the suitable design approachdepending on your general design considerations

    Calculate the seismic design resistances for N, V and load combination

    considering the characteristic resistances from the ETA

    If required, verify to DLS comparing required / anchor displacements

    considering the loads for the DLS verification

  • 8/10/2019 Calcul Hilti Ancore

    14/15

    Seismic Academy I Bologna 8 Novembre 2013 | J. Gramaxo 14www.hilti.it/sismico

    Currently seismic approved Hilti solutions for

    seismic performance category C1 and C2

    Structural

    application

    Non-structural

    application

    ETA C2 ETA C1*

    ETA C2

    * For buildings class IV: C2 required

    Source: Countries seismic acceleration maps ;

    EOTA TR045 recommendations

    HST / HST-R

    C2:M10-M16 ; C1:M10-M16

    HIT-HY 200 + HIT-Z

    C2:M12-M16 ; C1:M8-M20

    Seismic Category C2

    http://www.google.pt/url?sa=i&rct=j&q=Hilti+HIT-Z&source=images&cd=&cad=rja&docid=kZolt7vctfS7BM&tbnid=bGj5C7MtVrBx_M:&ved=0CAUQjRw&url=http://www.forconstructionpros.com/press_release/10885367/hit-hy-200-adhesive-anchor-system&ei=oeaUUefZL4XJPJm3gPAJ&bvm=bv.46471029,d.Yms&psig=AFQjCNFn12h9xr3cKPqHE_kNXNz7NBgIMw&ust=1368799246216176
  • 8/10/2019 Calcul Hilti Ancore

    15/15

    Seismic Academy I Bologna 8 Novembre 2013 | J. Gramaxo 15www.hilti.it/sismico

    Hilti Seismic Academy

    Jorge Gramaxo

    Technical Marketing

    Hilti AG

    Thank you for your attention!