Capillary Capillary ElectrophoresisElectrophoresis
8/9/2019 Capillary Electrophoresis Gammaru_caspe
2/47
2
1. Introduction2. Electrophoresis Overview3. Importance Of separation technique4. Why capillary Electrophoresis5. What is CE6. Types of CE
7. CE The Basics of the instrumentation8. Theory of Capillary Electrophoresis9. Electroosmotic Flow10.Electroosmotic Mobility11.Flow in CE12.The Electrophoregram13.Equipment of CE14.Methods For Improving Efficiency of CE15.Application
16.Summary and conclusion17.
CONTENTCONTENT
SS
8/9/2019 Capillary Electrophoresis Gammaru_caspe
3/47
3
PRINCIPLE AND INSTRUMENTATIONPRINCIPLE AND INSTRUMENTATIONOF CAPILLARY ELECTROPHORESISOF CAPILLARY ELECTROPHORESIS
:PRESENTED BY,Caspe Nerlizabel Rose
, .Gammaru Anabel A-Bs bilogy 3 1d
8/9/2019 Capillary Electrophoresis Gammaru_caspe
4/47
Definition of terms CE- capillary electrophoresis E- electric field strength EOF- electroosmotic EPF-Electrophoretic flow Ld- length of the capillary to the detector Lt- total capillary length Uep- electrophoretic mobility pI- isolectric point V-volt V- voltage VeO- electroosmotic flow velocity
Vep- electrophoretic velocity
8/9/2019 Capillary Electrophoresis Gammaru_caspe
5/47
5
ElectrophoresisAnElectrophoresisAnOverviewOverview
Definition: The differential movementfor migration of ions by attractionor repulsion in an electric field.
Separation of components of amixture using an electric field
v=Eq/f v = velocity of molecule E = electric field q = net charge of molecule f = friction coefficient
8/9/2019 Capillary Electrophoresis Gammaru_caspe
6/47
6
Electrophoresis- overviewElectrophoresis- overviewcontcont ..
Can determine the size, shape, andcharge of a molecule
Different forms of electrophoresisare used for each of these factorsindependently or in combination.
8/9/2019 Capillary Electrophoresis Gammaru_caspe
7/47
7
Types of Electrophoresis Types of Electrophoresis Capillary Native Polyacrylimide Gel
Electrophoresis (PAGE) Slab Paper
8/9/2019 Capillary Electrophoresis Gammaru_caspe
8/47
8
BasicsBasicscont.cont.
A photocathode is thenused to measure theabsorbencies of themolecules as they passthrough the solution
The absorbencies areanalyzed by acomputer and they are
represented graphically
8/9/2019 Capillary Electrophoresis Gammaru_caspe
9/47
9
Capillary Electrophoresis TheCapillary Electrophoresis TheBasics Of InstrumentationBasics Of Instrumentation
Electrophoresis in a buffer filled, narrow-bore capillaries
Each capillary is about 25-100 m in
internal diameter When a voltage is applied to the solution,the molecules move through the solutiontowards the electrode of opposite charge
Depending on the charge, the moleculesmove through at different speeds Separation is achieved
8/9/2019 Capillary Electrophoresis Gammaru_caspe
10/47
10
8/9/2019 Capillary Electrophoresis Gammaru_caspe
11/47
11
Cont.
8/9/2019 Capillary Electrophoresis Gammaru_caspe
12/47
12
Capillary ElectrophoresisCapillary ElectrophoresisApparatusApparatus
8/9/2019 Capillary Electrophoresis Gammaru_caspe
13/47
Electrophoresis a separation technique based on
the differential transportation of charged species in an electric fieldthrough a conductive medium.
Primary candidates for CE separationare ions.
The basic instrumental set-up, consistsof a high voltage power supply (0 to30 kV), a fused silica (SiO2) capillary,two buffer reservoirs, two electrodes,and an on-column detector.
8/9/2019 Capillary Electrophoresis Gammaru_caspe
14/47
Capillary electrophoresis(CE)
is a family of related techniques that employ
narrow-bore (20-200 mm i.d.) capillaries toperform high efficiency separations of bothlarge and small molecules .
separations are facilitated by the use of high voltages, which may generateelectroosmotic and electrophoretic flowof buffer solutions and ionic species,respectively, within the capillary .
The properties of the separation and theensuing electropherogram havecharacteristics resembling a cross
between traditional polyacrylamide gelelectro horesis (PAGE) and modern hi h
8/9/2019 Capillary Electrophoresis Gammaru_caspe
15/47
Electrophoresisterminology
under ideal conditions, nothing isretained, so the analogous termbecomes migration time.
The migration time ( tm) is thetime it takes a solute to movefrom the beginning of the capillaryto the detector window.
Other fundamental terms are definedbelow. These include theelectrophoretic mobility, mep(cm2/Vs), the electrophoreticvelocity, vep (cm/s), and the
8/9/2019 Capillary Electrophoresis Gammaru_caspe
16/47
h e r e l a t i on sh ip s .between these factors are shown in Equation 1
Equation 1 is only useful for determining the.apparent mobility To calculate the actual
,mobility the phenomenon of electroosmotic flow.must be accounted for To perform reproducible
,electrophoresis the electroosmotic flow must be.carefully controlled
8/9/2019 Capillary Electrophoresis Gammaru_caspe
17/47
Electroosmosis This phenomenon is a consequence
of the surface charge on the wall of the capillary.
A vitally important feature of CE isthe bulk flow of liquid through thecapillary.
This is called the electroosmotic flowand is caused as follows
8/9/2019 Capillary Electrophoresis Gammaru_caspe
18/47
- -The negatively charged wall attracts positively charged ions, .from the buffer creating an electrical double layer When a
,voltage is applied across the capillary cations in the diffuse portion of the double layer migrate in the direction of the, .cathode carrying water with them
The result is a net flow of buffer solution in the direction of.the negative electrode
8/9/2019 Capillary Electrophoresis Gammaru_caspe
19/47
19
-tern s model of the double layer charge distribut ion at a
egatively charged capi llary wall leading to the generation f a zeta potential and EOF
8/9/2019 Capillary Electrophoresis Gammaru_caspe
20/47
20
Electroosmotic MobilityElectroosmotic Mobility
Zeta Potential The change
in potentialacross adoublelayer
Proportionalto thecharge onthe capillarywalls and tothe
8/9/2019 Capillary Electrophoresis Gammaru_caspe
21/47
Effects of pH
8/9/2019 Capillary Electrophoresis Gammaru_caspe
22/47
22
Flow Profile in CE A further key feature of EOF is that it has flat flow
profile, which is shown in Figure alongside the
parabolic flow profile generated by an externalpump, as used for HPLC.
EOF has a flat profile because its driving force (ie.,charge on the capillary wall) is uniformly
distributed along the capillary, which means thatno pressure drops are encountered and the flowvelocity is uniform across the
capillary.
In HPLC, in which frictional forces at the column wallscause a pressure drop across the column, yieldinga parabolic or laminar flow profile.
The flat profile of EOF is important because itminimizes zone broadening, leading to highseparation efficiencies that allow separations onthe basis of mobility differences as small as 0.05
8/9/2019 Capillary Electrophoresis Gammaru_caspe
23/47
23
8/9/2019 Capillary Electrophoresis Gammaru_caspe
24/47
24
Electropherogram
The data output from CE ispresented in the form of an electropherogram,which is analogous to achromatogram.
An electropherogram is a
plot of migration time vs.detector response. The detector response is
usually concentrationdependent, such as UV-visible absorbance orfluorescence.
The appearance of a typicalelectropherogram isshown in Figure for theseparation of athreecomponentmixture of cationic, neutral and
8/9/2019 Capillary Electrophoresis Gammaru_caspe
25/47
25
EquipmentEquipment Capillary tube
Varied lengthbutnormally25-50 cm
Small boreandthickness of
the silicaplay a role
Using asmallerinternaldiamet
8/9/2019 Capillary Electrophoresis Gammaru_caspe
26/47
26
EquipmentEquipment Cont.Cont. Detector
UV/Visible absorption Fluorescence Radiometric (for radioactive
substances) Mass Spec.
8/9/2019 Capillary Electrophoresis Gammaru_caspe
27/47
Effects of voltage andtemperature
Both the electroosmotic andelectrophoretic velocities are directlyproportional to the field strength, so theuse of the highest voltages possible will
result in the shortest times for theseparation. Short separation times will give the
highest efficiencies since diffusion is the
most important feature contributing tobandbroadening.
The limiting factor here is Joule heating.Experimentally, the optimal voltage isdetermined by performing runs at
8/9/2019 Capillary Electrophoresis Gammaru_caspe
28/47
The electrophoreticmobility and theelectroosmoticflow expressions bothcontain a viscosity term in thedenominator.
Viscosity is a function of temperature;therefore, precise temperature controlis important. As the temperatureincreases, the viscosity decreases;thus, the electrophoretic mobilityincreases as well.
Some buffers such as Tris are known tobe pH-sensitive with temperature. Forcomplex separations such as peptide
maps, even small pH shifts can alter
8/9/2019 Capillary Electrophoresis Gammaru_caspe
29/47
29
HINTS FOR IMPROVING EFFICIENCY OF CE
Buffers Additives for CZE Additives for HPCE Hints Ionic Strength in HPCE PKa Values of Common Buffers
Proteins, Choosing a Proper Buffer Capillaries
Conditioning Dimensions, Changing How to Properly Cut A Capillary (Animated) Storage
Data Analysis Migrating Peak Correction
http://www.microsolvtech.com/cehint15.asphttp://www.microsolvtech.com/cehint2.asphttp://www.microsolvtech.com/cehint3.asphttp://www.microsolvtech.com/cehint14.asphttp://www.microsolvtech.com/cehint6.asphttp://www.microsolvtech.com/cehint6.asphttp://www.microsolvtech.com/cehint16.asphttp://www.microsolvtech.com/cehint5.asphttp://www.microsolvtech.com/cehint13.asphttp://www.microsolvtech.com/cutcap.asphttp://www.microsolvtech.com/cehint4.asphttp://www.microsolvtech.com/cehint1.asphttp://www.microsolvtech.com/cehint1.asphttp://www.microsolvtech.com/cehint4.asphttp://www.microsolvtech.com/cutcap.asphttp://www.microsolvtech.com/cehint13.asphttp://www.microsolvtech.com/cehint5.asphttp://www.microsolvtech.com/cehint16.asphttp://www.microsolvtech.com/cehint6.asphttp://www.microsolvtech.com/cehint6.asphttp://www.microsolvtech.com/cehint14.asphttp://www.microsolvtech.com/cehint3.asphttp://www.microsolvtech.com/cehint2.asphttp://www.microsolvtech.com/cehint15.asp8/9/2019 Capillary Electrophoresis Gammaru_caspe
30/47
30
ApplicationsApplications
Analysis of carbohydrates
Analysis of inorganic
anions/metal ions DNA profiling Protein identification
Advantages Fast Small Sample Relatively
inexpensive Automated
Disadvantages Cannot identify
neutral
species Joule Heating Cannot discern
shape
8/9/2019 Capillary Electrophoresis Gammaru_caspe
31/47
31
Summary
1. CE is based on the principles of electrophoresis.
2. The speed of movement or migration of solutes in CE is determined by their
3. size and charge. Small, highly chargedsolutes will migrate more quickly thanlarge, less charged solutes.
4. Bulk movement of solutes is caused by EOF.5. The speed of EOF can be adjusted by
changing the buffer pH used.6. The flow profile of EOF is flat, yielding high
separation efficiencies.7. The data output from CE is called an
electropherogram.
8/9/2019 Capillary Electrophoresis Gammaru_caspe
32/47
32
Conclusion It is the most efficient separation
technique available for the analysisof both large and small molecules.
DNA Profiling, protein identification,inorganic metals and ions can be
detected easily by this method.
8/9/2019 Capillary Electrophoresis Gammaru_caspe
33/47
Modes of capillaryelectrophoresis
Capillary zone electrophoresis Isoelectric focusing Capillary gel electrophoresis Isotachophoresis Micellar electrokinetic capillary
chromatography
8/9/2019 Capillary Electrophoresis Gammaru_caspe
34/47
Capillary zoneelectrophoresis
Simplest form of CE. Capillary zone electrophoresis (CZE),
(free solution capillary
electrophoresis) The separation mechanism is based
on differences in the charge-to-
mass ratio Fundamental to CZE are
homogeneity of the buffersolution and constant field
8/9/2019 Capillary Electrophoresis Gammaru_caspe
35/47
The net charge is usually pH
dependent. Separations of both large and small
molecules can be accomplished byCZE.
Even small molecules, where thecharge-to-mass ratio differencesmay not be great, may still beseparable.
8/9/2019 Capillary Electrophoresis Gammaru_caspe
36/47
8/9/2019 Capillary Electrophoresis Gammaru_caspe
37/47
Effect of pH. At a high pH where EOF is substantial, the
order of migration will be cations, neutrals,and anions. None of the neutral molecules willbe separated since the net charge is zero.
The anions will still migrate toward the cathodebecause the EOF is greater than theelectrophoretic migration.
At lower pH where the EOF is greatly reduced,both cations and anions can still bemeasured, although not in a single run. Tomeasure anions, the anode must be beyondthe detector window. Likewise, to measurecations, the cathode must reside beyond thedetector window.
The proper electricalconfiguration is achievedby simply reversing the polarity of the
8/9/2019 Capillary Electrophoresis Gammaru_caspe
38/47
Buffers A wide variety of buffers can beemployed in CZE. buffer is most effective within one or
two pH units of its pI. Zwitterionic buffers such as bicine,
tricine, CAPS, MES, and Tris are alsocommon, particularly for protein andpeptide separations. The advantageof the zwitterionic buffer is its lowconductivity when the buffer isemployed around the pI.
The advantage therein is the lowcurrent draw andthus reduced oule
8/9/2019 Capillary Electrophoresis Gammaru_caspe
39/47
Isoelectric focusing The fundamental premise of isoelectric
focusing (IEF) is that a molecule willmigrate so long as it is charged.
IEF is run in a pH gradient where the pH islow at the anode and high at the cathode .
The pH gradient is generated with a seriesof zwitterionic chemicals known ascarrier
ampholytes. When a voltage is applied, the
ampholyte mixture separates in thecapillary.
Ampholytes that are positively charged will
migrate towards the cathode while thosene ativel char ed mi rate towards the
8/9/2019 Capillary Electrophoresis Gammaru_caspe
40/47
Application In addition to performing high
resolution separations, IEF isuseful for determining the pI of aprotein.
IEF is particularly usefulforseparating immunoglobulins,
hemoglobin variants and post-translational modifications of recombinant proteins.
8/9/2019 Capillary Electrophoresis Gammaru_caspe
41/47
Capillary gelelectrophoresis
Traditional gel electrophoresis isconducted in an anticonvectivemedium such as polyacrylamide oragarose.
The composition of the media canalso serve as a molecular sieve to
perform size separations
8/9/2019 Capillary Electrophoresis Gammaru_caspe
42/47
physical gel Chemical gels
There are two fundamentalclasses of gels
8/9/2019 Capillary Electrophoresis Gammaru_caspe
43/47
Isotachophoresis was the most widely used
instrumental capillaryelectrophoretic technique, althoughthe capillaries were quite wide(250-500 mm) by todaysstandards.
8/9/2019 Capillary Electrophoresis Gammaru_caspe
44/47
Micellar electrokineticcapillary chromatography
Micelles are amphiphilic aggregatesof molecules known assurfactants.
They are long chain molecules(10-50 carbon units) and arecharacterized as possessing a long
hydrophobic tail and a hydrophilichead group.
8/9/2019 Capillary Electrophoresis Gammaru_caspe
45/47
8/9/2019 Capillary Electrophoresis Gammaru_caspe
46/47
8/9/2019 Capillary Electrophoresis Gammaru_caspe
47/47
Caspe, Nerlizabel Rose C.Gammaru, Anabel A.