3
Canon iP1900 tidak membutuhkan Software Resetter. Untuk melakukan Ink Full Tank Resetter lakukan langkah berikutnya : 1. Hidupkan printer Canon iP1900 (Turn On iP1900) 2. Tekan dan tahan tombol Resume selama 2 menit. (Push and Hold Resume button about 2 minutes) 3. Lepaskan tombol Resume. (Release Resume button) 4. Printer akan normal kembali. (Printer back to normal again) 5. Lalu Gunakan Softwarenya deh 6. Semoga Berhasil Bang …. From: Ancux, Makassar NB: klo mau pesan software yang lain bisa sms ato call ke http://indoresetter.blogspot.com (Ancux) CARA RESET Canon iP1900 Canon iP1900 tidak membutuhkan Software Resetter. Untuk melakukan Ink Full Tank Resetter lakukan langkah berikutnya : 1. Hidupkan printer Canon iP1900 (Turn On iP1900) 2. Tekan dan tahan tombol Resume selama 2 menit. (Push and Hold Resume button about 2 minutes) 3. Lepaskan tombol Resume. (Release Resume button) 4. Printer akan normal kembali. (Printer back to normal again) ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––- Canon ip1980 is successor of ip1880. It has similar design and parts inside. For your information, there are some improvements made for this printer. I will tell you about this later ok?. Well, so far Canon Official Team does not release General Tools (resetter) for this printer yet. So, what if waste ink absorber full error happens to your ip1980 printer?. What can we do?. Relax man. Do not panic. Just use General Tools (resetter) for Canon pixma ip1880. It completely works. –––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––- 3x Orange 1x green Problem : any problem with printer mechanics Solution: If you don’t have knowledge about printer mechanic, will better if bring the printer to Canon service center. 4x orange 1x green Problem printer absorber full Solution: Reset the printer using generaltools or software resetter. If not work using reset manual. Each printers having different set of manual reset 5x orange 1x green Problem: Black or Color cartridge trouble. Note: problem is usually caused many matters, for example chips error, conector is dirty, etc. 7x orange 1x green Problem: Black or Color cartridge trouble. Note: problem is usually caused many matters, for example chips error, conector is dirty, etc. 8x orange 1x green Problem printer absorber full (Waste Ink Pad Full) Solution: Reset the printer using generaltools or software resetter. If not work using reset manual. Each printers having different set of manual reset

Cara Reset Canon iP1900

Embed Size (px)

DESCRIPTION

Cara Reset Canon iP1900

Citation preview

Page 1: Cara Reset Canon iP1900

Canon iP1900 tidak membutuhkan Software Resetter. Untuk melakukan Ink Full Tank Resetter lakukan langkah berikutnya : 1. Hidupkan printer Canon iP1900 (Turn On iP1900)2. Tekan dan tahan tombol Resume selama 2 menit. (Push and Hold Resume button about 2 minutes)3. Lepaskan tombol Resume. (Release Resume button)4. Printer akan normal kembali. (Printer back to normal again)5. Lalu Gunakan Softwarenya deh6. Semoga Berhasil Bang ….

From: Ancux, MakassarNB: klo mau pesan software yang lain bisa sms ato call ke http://indoresetter.blogspot.com (Ancux)

CARA RESET Canon iP1900Canon iP1900 tidak membutuhkan Software Resetter. Untuk melakukan Ink Full Tank Resetter lakukan langkah berikutnya : 1. Hidupkan printer Canon iP1900 (Turn On iP1900)2. Tekan dan tahan tombol Resume selama 2 menit. (Push and Hold Resume button about 2 minutes)3. Lepaskan tombol Resume. (Release Resume button) 4. Printer akan normal kembali. (Printer back to normal again)

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––-Canon ip1980 is successor of ip1880. It has similar design and parts inside. For your information, there are some improvements made for this printer. I will tell you about this later ok?.Well, so far Canon Official Team does not release General Tools (resetter) for this printer yet. So, what if waste ink absorber full error happens to your ip1980 printer?. What can we do?. Relax man. Do not panic. Just use General Tools (resetter) for Canon pixma ip1880. It completely works.

–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––-3x Orange 1x green Problem : any problem with printer mechanicsSolution: If you don’t have knowledge about printer mechanic, will better if bring the printer to Canon service center.4x orange 1x green Problem printer absorber fullSolution: Reset the printer using generaltools or software resetter. If not work using reset manual. Each printers having different set of manual reset5x orange 1x green Problem: Black or Color cartridge trouble.Note: problem is usually caused many matters, for example chips error, conector is dirty, etc.7x orange 1x green Problem: Black or Color cartridge trouble.Note: problem is usually caused many matters, for example chips error, conector is dirty, etc.8x orange 1x green Problem printer absorber full (Waste Ink Pad Full)Solution: Reset the printer using generaltools or software resetter. If not work using reset manual. Each printers having different set of manual reset––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––-CANON PIXMA IP1900 is just a successor of ip1880 PARTS & MANUALS ARE THE SAME but a little bit faster than 1880

1. USE GENERAL TOOL CHANGE USB PORT change into CANON PORT2. click lock release3. click ip18004. click device id5. clear waste ink counter by clicking MAIN & PLATEN6. Check EEPROM Box7. Click EEPROM Dump8. Test pattern 19. Your Done…

but this is not the end of your problemEVERYTIME YOU CLEAR WASTE INK COUNTER you have to open your printerand wash the INK PAD and let it dry it will damage any part of your computer if youwill not do this.–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––

Page 2: Cara Reset Canon iP1900

RESETTER IP1980Saturday, 6. December 2008, 02:09:23Untuk mereset printer canon IP1980 gunakan reseter IP1880 dijamin OK

Error code canon IP1300, IP1700, IP1200, IP1880, IP19803x orange 1x hijau = mekanik error4x orange 1x hijau = absorber full > direset dengan general tools5x orange 1x hijau = cartirdge black/colour bermasalah7x orange 1x hijau = cartirdge black/colour bermasalah8x orange 1x hijau = absorber full > direset dengan general tools12x / 15x orange 1x hijau = cartridge detection-–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––-Canon PIXMA iP1980 Photo Printer, featuring the FINE Cartridge for fast and quality photo printing, 2 picoliter ink droplets and resolution of 4,800 x 1,200 dpi, finishes a fine 4" x 6" borderless printing in just 55 seconds. Up to 100-year album life can be achieved with new ChormaLife 100's FINE cartridge and Photo Paper Pro or Photo Paper Plus Glossy or Photo Paper Plus Semi-gloss or Glossy Photo Paper. This stylishly designed printer fits perfectly in any surroundings. The reasonable price of iP1980 makes it become the first choice of Students for printing solution.

From the design Canon ip1980 is same as pixma ip1880. If there are some problems in ip1980 such as waste ink absorber full error you just remember General Tools (resetter)for Canon Pixma ip 1880.

How to reset ink level on Canon Pixma iP1800

1. press power button while plug in the powerchord - green lamp.2. while hold the power button press resume button twice - orangeblink and return to green.3. release the power button, - the prnter will start.4. try to print a page.5. hope it's work.

Note: If resetting the printer does not work, please attempt any other solutions. Download Sofware Reset Reset Waste Ink Counter for Canon Pixma ip1980–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––-1. Turn off printer.2. Hold down Resume button and press Power button.3. Keep holding down Power button and let Resume button go.4. Press Resume button 2 times then let BOTH buttons go.5. Green lights will flash and then stop blinking.6. When green lights are solid, press the Resume button 4 times.7. Press the Power button and the printer should turn off, if not, press the Power button once more.8. Your printer should respond as normal.