2015.04Catalogue
TRIOL Articial Lift Surface Equipment
www.triolcorp.com
7/26/2019 Catalog Po Ak 2015
2/381
Introduction
Dear customer!
The present catalogue covers articial lift surface equipment Triol AK series forcontrol and protection of submersible electric motors. It contains information relatedto application, functionality, technical characteristics, connection diagrams, andoverall dimensions.
For your convenience the products are divided into two sections containinginformation about models with NEMA enclosures and with IP43 enclosures for indoor/outdoor installation in a cold climate (according to industry standard GOST 15150-69).The catalogue covers three series, AK01, AK02, and AK06, with detailed descriptions forall models. Our equipment is a good solution for specic environmental conditions ofMiddle East, Asian Pacic, South America and Siberia.
Triol Corporation successfully combines experience and innovation. We providedevelopment, production, reliable supply and after-sales service throughout the world.
We appreciate our Partners and Customers and are always open for cooperation!
7/26/2019 Catalog Po Ak 2015
3/382
Versions of variable speed drive Triol AK
Equipment for submersible
motors
Triol AK01
series
Type
GOST 15150-69
Type
NEMA 250.1.
IP43, outdoors,
cold climate NEMA3
NEMA4X
NEMA4
380 V 480 V
660 V 4 kV
1 5 kV
380 V 380 V
480 V
6-pulse, FPWM
6-pulse, 6-step
12-pulse, FPWM
12-pulse, 6-step
active input filter, FPWM
480 V / 380 V380 V
filtered PWM output
for permanent magnet motors
for induction and permanent magnet motors
active input filter
active input filter, filtered PWM output
500 V / 380 V
6-pulse, Filtered PWM output
activefront-end
NEMA3
NEMA4X
NEMA4
NEMA3
NEMA4X
NEMA4
Triol AK02
series
Triol AK06
series
Triol AK06
series
Triol AK02
series
Triol AK01
series
linear permanent magnet motors
480 V
IP43, outdoors,
cold climate
IP43, outdoors,
cold climate
6-pulse, FPWM
active input filter, FPWM
7/26/2019 Catalog Po Ak 2015
4/38
7/26/2019 Catalog Po Ak 2015
5/38
AK**-XX-Y1Y2Y3Y4Y5Y6-Z-
4
Product code structure
Triol AK** series01 Switchboard (D.O.L. motor starter).02 Soft starter.06-AM Variable speed drive for induction motor.06-AH Variable speed drive for high speed induction motor.06-PC Variable speed drive for progressive cavity pumps.06-PM Variable speed drive for permanent magnet motor.06-PH Variable speed drive for high-speed permanent magnet motor.06-MM Variable speed drive for induction or permanent magnet motor(multipurpose version).06-SM Variable speed drive for synchronous motor.06-LL Variable speed drive for linear permanent magnet motors.06-ASPED Variable speed drive with automated system providing oil production
eciency increase.
Type of equipment (X)
Type of Triol AK Rated current, A
100 100
160 160
250 250
400 400
630 630
800 80010 1000
12 1200
14 1400
16 1600
18 1800
20 2000
25 2500
32 3200
tro
7/26/2019 Catalog Po Ak 2015
6/38
AK**-XXX-Y1Y2Y3Y4Y5Y6--Z
5
Rectier type (Y1)
0 Thyristor-thyristor six-pulse bridge rectier1 Transistor active front-end
2 Half-controlled six-pulse bridge rectier3 Half-controlled twelve-pulse bridge rectier4 Half-controlled eighteen-pulse bridge rectier5 Soft starter without frequency converter6 Uncontrolled six-pulse bridge rectier7 Passive input grid lter8 With active lter
Sinewave lter (Y2)
0 Without build-in sine output lter1 With build-in sine output lter
Bypass system (Y3)
0 Without bypass device1 With bypass (optional)
Enclosure climatic version (Y4)
0 Enclosure type for cold and moderate climates (1 according to GOST 15150-69)1 Enclosure type for tropical dry zone (IP43, outdoor, cold climate)2 Operating conditions according to EN 61439-1:2010 for outdoor installation.Custom climatic version.
Controller type (Y5)
0 Without controller1 Provision for connection to a third party controller2 Modication upon customer request3 With UMKA-03 controller4 With UMKA-04 controller5 With UMKA-05 controller
Modication (Y6)
0 VSD basic modication
1...9 customized modication based on the clients requirements
Meter type ()
SET meter SET-4MER meter MerkuriyENM meter Energomer
Supply voltage (Z)
380 supply voltage of 380 V480 supply voltage of 480 V660 supply voltage of 660 V4000 supply voltage of 4000 V5000 supply voltage of 5000 V
Intro
7/26/2019 Catalog Po Ak 2015
7/38
7/26/2019 Catalog Po Ak 2015
8/38
NEMA type
Intro
7
Triol Corporation has made a step forward by releasing products with protectionclasses NEMA 3, 4, and 4X according to standard NEMA 250.1.
Equipment with NEMA 3 enclosures is intended for indoor and outdoor use and provides
protection against rain and snow. The enclosure also protects the user from accidentalcontact with live parts. In general it exceeds the performance requirements of IP55.
Equipment with NEMA 3 enclosures is intended for outdoor use and providesprotection against dust and moisture similar to IP66 in the temperature range fromminus 20 to +60C (4 to +140F). The NEMA4X diers from NEMA4 in its corrosionresistance.
To satisfy the requirements of class NEMA4/4X Triol Corporation has developedan air-tight cabinet with a special type of covering that withstands all necessary tests.For the most demanding applications there is a version with the cabinet made ofstainless steel which provides unique protection from corrosive medium and is suitablefor equipment to be used at manufacturing plants or oshore platforms.
The NEMA4 protection class of VSD AK series is provided by: Special corrosion-resistant fans that are also resistant to dust and sand; Built-in heat exchangers for removing heat from the power compartment providing
operation at ambient temperatures of up to +60C (+140F); Dust and sand catchers allow operation of the cooling system in dusty environments; Corrosion resistance of the enclosure is provided by a special paint coating while
that of the DC-link chokes is provided by special compound they are impregnatedwith (for NEMA4);
The highest corrosion resistance is provided by an enclosure made of stainless
steel while the cooled DC-link chokes are impregnated with special compound(for NEMA4H);
To remove moisture from air-tight compartments special unidirectional IP66diaphragms and dehumidier based on Peltier elements are used.
7/26/2019 Catalog Po Ak 2015
9/388
Input section topology
6 pulse rectier
Supplymains
connection
ABC
Output 3-phases voltage
U V W
The power circuit with 6-pulse rectier (Graetz bridge) is shown in the Figure. With thistopology there is voltage ripple with a frequency of 300 Hz at the output of the rectierbridge. For smoothing the current waveform an LC-lter is applied. The lter reducesharmonic emission into the power network.
When using AK VSDs in networks with strict requirements to waveform distortion it isrecommended to use a three-phase lter.
12 pulse rectier
Supplymains
connection
Supplymains
connection
Output 3-phases voltage
A1B1C1
U V W
A2
B2C2
The 12-pulse rectier is the most widespread solution at the moment as it is muchbetter than 6-pulse scheme in terms of harmonic emission into the mains.
There are two versions of the four-winding isolation transformers available: dry type(for indoor installation) and oil type (for outdoor installation). This gives maximum
exibility when selecting a solution depending on the available oor space, installationcosts, and permissible load on the air-conditioning system used to maintain the desiredroom temperature.
tro
7/26/2019 Catalog Po Ak 2015
10/389
Active Harmonic Filter
ABC
U V W
Supplymains
connection
Output 3-phases voltage
Presence of non-linear loads causes the higher order harmonics (5, 7, 11, and higher)to appear in the network. It has a negative eect on equipment as a whole (additionalheating of wiring, inecient use of energy, reducing life of insulation, overheating oftransformers, etc.)
To limit such distortions appropriate technologies and standards were introduced. Thisprocess has been quite successful in the sense that the problems faced by consumersalmost always arise due to the conditions that appear in their own area of responsibility,and only rarely are brought from the mains. If this situation continues consumers will haveto limit the level of harmonic current created by their equipment. Consequently consumeris the one who should provide ltering of harmonic components where necessary.
There are several methods of reducing the harmonic currents owing into the mainsduring operation of semiconductor converters. One of such methods is the use of passiveresonant lters that are bulky and have some other shortcomings.
A more advanced method is the active interference suppression which is achieved byinjecting into the network harmonic currents that are equal to those already present inthe network but are opposite in phase.
Total harmonic distortion in the input current for this VSD is less than 5% which totallycomplies with IEEE519. The AK06 VSD with active harmonic lters does not need bulkypassive lters or use of 12, 18, or 24-pulse phase shifting transformers, since it can be fedfrom an ordinary two winding transformer (one primary and one secondary windings).
Also the active lter provides fast response to changes in current harmonic compositionresulting in the most eective interference suppression.
Intro
7/26/2019 Catalog Po Ak 2015
11/38
N-10
.01
AK01--500241- Switchboard
Application
Triol AK01 starter with NEMA3/4/4X enclosure, 660 V ... 4 kV, is a reliable, safe and low costsolution for controlling submersible motors with 600 V to 4 kV voltage ratings.
Rated voltage
Rated inputvoltage, V
Rated outputcurrent, A
Rated power ofmotor, kW
Rated power ofmotor, hp
Ordering code
660 4000200 100 135.96 01-200-500241-
400 200 271.92 01-400-500241-
7/26/2019 Catalog Po Ak 2015
12/38N-11
N.01
Host offunctions
D.O.L. start of submersible pump motors; Re-start blocking during motor rundown (rundown delay); Local and remote control of operating modes; Protection against short-circuit currents and overloads;
Provision for control with feedback from a submersible transducer; Protection settings may be checked and changed via RS-485; Operation in two modes: Manual and Automatic; Measurement of active energy, reactive energy, and total energy consumption; Automatic pump switching on with an adjustable time delay (from 1 to 9999 minutes)
after supply voltage is applied; Motor operation blocking in case of wrong phase sequence on the input of the starter; Motor operation blocking if the supply voltage is out of tolerance; Motor tripping with further automatic restart in case of severe supply voltage deviations
(higher or lower by more than 25% of the rated value) causing an overcurrent condition; Motor tripping when any phase is underloaded with selectable minimum phase current
and time delay; Motor tripping in case of overload according to programmable time-current characteristic; Automatic restart of motor after tripping by underload protection with preset time delay
(from 1 to 9999 minutes); Operation mode setting: with automatic restart after a trip or without automatic restart
after a trip; Motor operation blocking if the pump is caused to rotate by ow of liquid (turbine
rotation) with selectable frequency threshold; Automatic blocking of manual turning on and control while operating with external
process control system;
Automatic restart after fault; Selection of operation with automatic periodic turning the motor on and o according
to preset timing diagram (from 1 to 28800 minutes); Continuous monitoring of motor and cable insulation resistance with tripping if
the resistance drops below the threshold value; Possibility of operation with decreased cable and motor resistance and fast tripping
under overload conditions; Light indication of D.O.L. starter operating mode (run, wait, stop); Light indication in case of emergency stop; Monitoring of the motor current and supply-line voltage;
Provision for tuning at site: overload/underload protection, supply line over- andundervoltage protection (operation threshold setting); Embedded memory for recording of current parameters during operation of the pump; Displaying on the screen: motor current, supply-line voltage, all presets, operating
modes including operation of protections, time to switching on/o in automatic modewith timer, time to trip when protection thresholds are exceeded,
Recording of motor tripping time and its cause; Tripping the motor and restart blocking when supply-line voltage imbalance protection
threshold is exceeded; Tripping the motor when the current imbalance protection threshold is exceeded; D.O.L. starter control basing on additional technical parameters: pump temperature,
pressure, and pumping unit vibration.
7/26/2019 Catalog Po Ak 2015
13/38
N-12
.01
AK01--500241- Switchboard
Technical characteristicsMain characteristics
Voltage, V 660...4000, +10 %, -10 %
Frequency, Hz 50 ... 60Enclosure NEMA3 NEMA4X
Operation temperature -20 ... +60 / 4 ... 140F
Rectication type without recier
Analog inputs 2
Digital inputs (opto-isolated,220 V a.c.)
2
Altitude characteristics up to 1000 m / 3280 ft
Standards NEMA 250-2008, GOST 17516.1-90
Protection functions
Alarms and protections
external and internal short-circuit
underload (trip on underload)
open-phase fault of input or output circuits
motor overload
power supply or control system fault
turning on at too low controller temperature
interlock preventing unauthorized access to
DOL starter settings
7/26/2019 Catalog Po Ak 2015
14/38N-13
N.01
External connection diagram
ESP ON
Control of the ESM
Digital inputs
Connecting TMS via RS-485
Internal power supply telemetry
Connecting an external automation
system via RS-485
External ban
Ain 1
Ain 2Ain common
ACS RS485 A+
ACS RS485 B-
ACS RS GND
ESP general
ESP OFF
+24 VPressure gauge
+24 V
Common analog input
Signal wire A RS485
5
2
TMS RS485 A+
TMS RS GND
TMS RXD
TMS TXD
TMS GND
Signal wire A RS485
Admission RS-232 data
~220 V
~220 V
Data transmission RS-232
Neutral wire RS232
~220 V
~220 V
Net
Net
TMS RS485 B-
ACVOT
Output U
Output V
Output W
Shield
Ground
Input3-phase
powercircuit
Neutral
Phase C
Phase B
Phase A
Description Appointment
Normally closed contacts
Common contact
Normally opened contacts
Digital input 1
Digital input 2
Analog input 1
Analog input 2
Signal wire B RS485
Neutral wire RS485
Power supply of digital inputs
Description Appointment
Signal wire B RS485
Neutral wire RS485
Telemetry connection
ESM
Circuit diagram
CasingCasing
Step-uptransforme
Output W
Output V
Output V
Output terminals
Circuit
Circuit
Terminal of external connections
Socket
Power switchQF1
Phase A
Phase B
Phase C Contactor
Inputterminals
Circuit
Circuit
Circuit
ESMON
ESMcommon
ESMOFF
+24V
Cont.pres.gauge
Externalblocking
Ain1
Ain2
Aincommon
ACSRS485A+
ACSRS485B
ACSRSGND
1 2 3 4 5 6 7 8 9 10
11
12
TMSTXD
TMSRXD
TMSGND
RS485A
RS485B
RS485GND
1 2 3 1 2 3
A1
A2
33
34
31
32
43
44
41
42
220V AC, 50Hz
220V AC, 50Hz
NO 1.1
NO 1.2
NC 1.1
NC 1.2
NO 2.1
NO 2.2
NC 2.1
NC 2.2
1
2
220V AC
220V AC
FU1
FU3
FU2
1L1
5L3
3L2
1L1
5L3
3L2
2T1
6T3
4T2
KM1
TA1
TA2
TA3
SA1
7/26/2019 Catalog Po Ak 2015
15/38
N-14
.01
AK01--500241- Switchboard
840 mm (33.07 in)
12 mm (0.472 in)
380mm
(14.9
6in)
760mm(
29.9
2in)
1815mm(
71.4
6in)
1330 mm (52.36 in) 1035 mm (40.75 in)
985mm(
38.7
8in)
535mm
(21.0
6in)
1497mm(
58.9
4in)
Dimensions
Height of cable connection points
7/26/2019 Catalog Po Ak 2015
16/38N-15
N.01
max 90
Sling arrangement
2518 mm (99.13 in)
2720mm(
107.09
in)
Overall dimensions with open door(s) + door opening clearances
7/26/2019 Catalog Po Ak 2015
17/38
N-16
.01
AK01--500241- Switchboard
Application
Triol AK01 starter with NEMA3/4/4X enclosure, 1 5 kV, is a reliable, safe and low costsolution for controlling submersible motors with voltage ratings from 1 kV to 5 kV.
Rated voltage
Rated inputvoltage, V
Rated outputcurrent, A
Rated power ofmotor, kW
Rated power ofmotor, hp
Ordering code
1 5000200 100 135.96 01-200-500241-
400 200 271.92 01-400-500241-
7/26/2019 Catalog Po Ak 2015
18/38N-17
N.01
Host offunctions
Motor switching on/o; Motor operation in the following modes: Manual (without automatic restart after
a trip); Automatic with automatic restart after a trip, and Automatic with operationaccording to preset timing diagram;
Current optimization after reaching a preset value of the motor frequency; Manual control of motor speed from UMKA-03 controller and remote control froma dispatching point;
Automatic change of the output frequency according to a preset timing diagram; Motor automatic starting after selectable delay when the supply voltage is applied; Automatic maintaining of some process parameters (pressure, current) at their setpoints; Measurement and indication of current parameters of submersible pump and VSD on
the integrated liquid-crystal display; Motor remote control, monitoring of motor parameters, uploading and downloading
of protection settings through telemetering system (downhole measured equipment)via RS485 interface;
Recording of trip events and corresponding current parameters into the integratednonvolatile memory;
Recording of modied settings into the event log with date and time corresponding tosuch modication;
Outdoor light alarm system indicating the pumping unit condition (run, wait, stop); Motor control with feedback from a submersible transducer; Congurable integrated protections: overload/underload, current imbalance, supply
voltage and DC-link voltage outside allowable limits, continuous operation at lowfrequency, power semiconductor overheating, operation at abnormal values ofparameters controlled by telemetering system (downhole);
Monitoring of input phase voltages. The drive is tripped or motor start is inhibited ifphase-loss condition is detected.
7/26/2019 Catalog Po Ak 2015
19/38
N-18
.01
AK01--500241- Switchboard
Technical characteristicsMain characteristics
Voltage, V 1000...5000, +10 %, -10 %
Frequency, Hz 50 ... 60Enclosure NEMA3 NEMA4X
Operation temperature -20 ... +60 / 4 ... 140F
Rectication type without rectier
Analog inputs 2
Digital inputs (opto-isolated,220 V a.c.)
2
Altitude up to 1000 m / 3280 ft
Standards NEMA 250-2008, GOST 17516.1-90
Protection functions
Alarms and protections
tripping in case of supply voltage deviation if suchdeviation results in overcurrent condition (withpossibility of auto-restart after voltage recovery)
overcurrent protection (OCP)
IGBT de-saturation protection
protection against current imbalance
motor overload protection
7/26/2019 Catalog Po Ak 2015
20/38N-19
N.01
External connection diagram
ESP ON
Control of the ESM
Digital inputs
Connecting TMS via RS-485
Internal power supply telemetry
Connecting an external automation
system via RS-485
External ban
Ain 1
Ain 2Ain common
ACS RS485 A+
ACS RS485 B-
ACS RS GND
ESP general
ESP OFF
+24 VPressure gauge
+24 V
Common analog input
Signal wire A RS485
5
2
TMS RS485 A+
TMS RS GND
TMS RXD
TMS TXD
TMS GND
Signal wire A RS485
Admission RS-232 data
~220 V
~220 V
Data transmission RS-232
Neutral wire RS232
~220 V
~220 V
Net
Net
TMS RS485 B-
ACVOT
Output U
Output V
Output W
Shield
Ground
Input3-phase
powercircuit
Neutral
Phase C
Phase B
Phase A
Description Appointment
Normally closed contacts
Common contact
Normally opened contacts
Digital input 1
Digital input 2
Analog input 1
Analog input 2
Signal wire B RS485
Neutral wire RS485
Power supply of digital inputs
Description Appointment
Signal wire B RS485
Neutral wire RS485
Telemetry connection
ESM
Circuit diagram
CasingCasing
Step-uptransforme
Output W
Output V
Output V
Output terminals
Circuit
Circuit
Terminal of external connections
Socket
Power switchQF1
Phase A
Phase B
Phase C Contactor
Inputterminals
Circuit
Circuit
Circuit
ESMON
ESMcommon
ESMOFF
+24V
Cont.pres.gauge
Externalblocking
Ain1
Ain2
Aincommon
ACSRS485A+
ACSRS485B
ACSRSGND
1 2 3 4 5 6 7 8 9 1
0
1
1
1
2
TMSTXD
TMSRXD
TMSGND
RS485A
RS485B
RS485GND
1 2 3 1 2 3
A1A2
33
34
31
32
43
44
41
42
220V AC, 50Hz220V AC, 50Hz
NO 1.1
NO 1.2
NC 1.1
NC 1.2
NO 2.1
NO 2.2
NC 2.1
NC 2.2
1
2
220V AC
220V AC
FU1
FU3
FU2
1L1
5L3
3L2
1L1
5L3
3L2
2T1
6T3
4T2
KM1
TA1
TA2
TA3
SA1
7/26/2019 Catalog Po Ak 2015
21/38
N-20
.01
AK01--500241- Switchboard
840 mm (33.07 in)
12 mm (0.472 in)
380mm
(14.9
6in)
760mm(
29.9
2in)
1815mm(
71.4
6in)
1330 mm (52.36 in) 1035 mm (40.75 in)
985mm(
38.7
8in)
535mm
(
21.0
6in)
1497mm(
58.9
4in)
Dimensions
Height of cable connection points
7/26/2019 Catalog Po Ak 2015
22/38N-21
N.01
max 90
Sling arrangement
2518 mm (99.13 in)
2720mm(
107.0
9in
)
Overall dimensions with open door(s) + door opening clearances
7/26/2019 Catalog Po Ak 2015
23/38
N-22
.06
06-AM--110231-480 Variable speed drive
Application
Triol AK06 variable speed drive with 6-pulse rectier and ltered PWM output,NEMA3/4/4X enclosure, 480 V, with system integration options for submersible pumpapplications. The drive provides enhanced motor performance and reliability.
Rated voltage
Ratedinput
voltage, V
Rated outputcurrent, A
Rated powerof motor, kW
Rated power ofmotor, hp
Ordering code
480
100 70 95.17 06-AM-100-110231-480
160 100 135.96 06-AM-160-110231-480
250 200 271.92 06-AM-250-110231-480
400 330 448.67 06-AM-400-110231-480630 520 706.99 06-AM-630-110231-480
800 660 897.34 06-AM-800-110231-480
1000 830 1128.47 06-AM-10-110231-480
1200 995 1352.80 06-AM-12-110231-480
1400 1160 1577.14 06-AM-14-110231-480
1600 1330 1808.27 06-AM-16-110231-480
1800 1495 2032.60 06-AM-18-110231-480
7/26/2019 Catalog Po Ak 2015
24/38N-23
N.06
Host offunctions
Motor switching on/o; Motor operation in the following modes: Manual (without automatic restart after
a trip); Automatic with automatic restart after a trip, and Automatic with operationaccording to preset timing diagram;
Current optimization after reaching a preset value of the motor frequency; Operation according to pre-programmed timing diagram with motor ON/OFF periodsprogrammed separately;
Manual control of motor speed from UMKA-03 controller and remote control fromsupervisory control console;
Automatic change of the output frequency according to a preset timing diagram; Motor acceleration and deceleration at preset rates (acceleration and deceleration ramps); Motor reversal; Motor automatic starting after selectable delay when the supply voltage is applied; Automatic maintaining of some process parameters (pressure, current) at their setpoints; Selectable motor starting modes: swinging, impact start (may be used for unjamming
the submersible unit), soft start with synchronization. Unjamming is done with maximumpossible motor torque at low speed;
Continuous monitoring of motor and cable insulation resistance with tripping ifthe resistance drops below the threshold value;
Possibility of operation with decreased cable and motor resistance and fast trippingunder overload conditions;
Measurement and indication of current parameters of submersible pump and VSD onthe integrated liquid-crystal display;
Motor remote control, monitoring of motor parameters, uploading and downloadingof protection settings through telemetering system (downhole measured equipment)
via RS485 interface; Recording of trip events and corresponding current parameters into the integrated
nonvolatile memory; Recording of modied settings into the event log with date and time corresponding to
such modication; Outdoor light alarm system indicating the pumping unit condition (run, wait, stop); Motor control with feedback from a submersible transducer; Congurable integrated protections: overload/underload, current imbalance, supply
voltage and DC-link voltage outside allowable limits, continuous operation at lowfrequency, power semiconductor overheating, operation at abnormal values of para-
meters controlled by telemetering system; Opening of the VSD door may be signalized to dispatching station through telemetering
system (downhole); Measurement of electric energy consumption; Monitoring of input phase voltages. The drive is tripped or motor start is inhibited if
phase-loss condition is detected.
7/26/2019 Catalog Po Ak 2015
25/38
N-24
.06
06-AM--110231-480 Variable speed drive
Technical characteristicsMain characteristics
Voltage, V 480 +15, -25%
Frequency, Hz 50 ... 60Eciency, % 97
Overload capability 125 % of the rated current for 300 seconds
Rectication type half-controlled six-pulse (Graetz bridge)
Analog inputs 2
Digital inputs (opto-isolated,220 V a.c.)
2
Enclosure NEMA3 NEMA4X
Operation temperature -20 ... +60 / 4 ... 140FAltitude up to 1000 m / 3280 ft
StandardsNEMA 250-2008, GOST 17516,1-90,GOST 18058-80, GOST 15150-69,
Protection functions
Alarms and protections
tripping in case of supply voltage deviation if suchdeviation results in overcurrent condition (withpossibility of auto-restart after voltage recovery)
tripping on underload
overload according to programmable time-currentcharacteristic
overcurrent protection (OCP)
tripping if motor and cable insulation resistancedrops below the threshold
motor stall protection
IGBT de-saturation fault protection
tripping in case of power modules overheating
tripping if parameters monitored by telemetering
system exceed preset valuestripping if pipeline pressure is outside the limits(using signals from contact pressure gauge)
tripping if power compartment door is opened
7/26/2019 Catalog Po Ak 2015
26/38N-25
N.06
External connection diagram
Normally closed contacts
ESP on
ESP common
ESP off
+24 V +24 V
Control of ESM operation
Power supply of discrete inputs
Pressure gauge Contact pressure gauge Digital input, contact pressure gauge
Ain 1.1 Analog input 1
Ain common Common analog input
Ain 1.2 Analog input 2Connection sensors of
submersible telemetry unit
ACS RS485 A+
ACS RS485 B-
Signal cable A RS485
Signal cable B RS485Connecting the external ACS
by RS-485ACS RS GND Neutral wire RS-485
Circuit Description Purpose
Signal cable A RS485
Signal cable B RS485
Neutral wire RS-485
Connect a digital telemetry
RS-485
Connect a digital telemetry
RS-232Neutral wire RS232
Data transmission RS232
Data receiving RS232
Telemetry power supply~ 220 V~ 220 V
Internal/external circuit
ACVOT-0
If the is a jumper in this terminal, Rizis measured by variable speeddrive, not by telemetry system
ACVOT-0
ACVOT-0
Casing ACVOT ESM
Control circuit ~220 V
GroundingGND
Input3480V
thereduction
ofpowertransformer
Circuit Description Purpose
Circuit Description Purpose
A
B
C
Neutral
TMS TXD
TMS RXD
TMS GND
TS RS GND
TS RS485 A+
TS RS485 B-
External bloking External blocking of turn-on External blocking of ESM start
Ain 2.1 Analog input 1
Ain common Common analog input
Ain 2.2 Analog input 2Connection sensors of
submersible telemetry unit
XT9
X3
X5
Din reserve Reserve digital input Reserve digital input
Circuit diagram
2
2
1
3
2
1
3
2
1
3
2
1
3
6
4
5
3
1
TA1
TA2
Power switchQF1
X1 Socket
Circuit
220V AC
220V AC
1
2
Terminal of external connections
X5
X3
ESMON
ESMcommon
ESMOFF
+24V
Cont.pres.gauge
Externalblocking
Ain1
Ain2
Aincommon
ACSRS485A+
ACSRS485B
ACSRSGND
Circu
it
1 2 3 4 5 6 7 8 9 10
11
12
Contact pressure gauge
TMS terminal (downhole sensors)
1 2 3 4 5 6 7 8 9 10
11
12
TMSRS485A+
TMSRS485B-
TMSRSGND
TMSTXD
TMSRXD
TMSGND
Ain1
Ain2
Aincommon
220VAC
220VAC
Circu
it
Casing
Casing
Step-uptransformer
Output W
Output V
Output V
Output terminals
Phase A
Phase B
Phase C
Inputterminals
TA3
7/26/2019 Catalog Po Ak 2015
27/38
N-26
.06
06-AM--110231-480 Variable speed drive
14 mm (0.55 in)
983 mm (38.70 in)
85
5mm(
33.6
6in)
2090mm(
82.2
8in)
1050 mm (41.34 in)
1360 mm (53.54 in)
1185 mm (46.65 in)
1350 mm (53.15 in)
External connections Transformer secondary star point
3-phase choke star point
connection star point
onnection panel
1247mm(
49.0
9in)
1286mm(
50.6
3in)
1337mm(
52.6
4in)
1599mm(
62.9
5in)
Dimensions
Height of cable connection points
7/26/2019 Catalog Po Ak 2015
28/38N-27
N.06
R224 mm (8.82 in)
R1019 mm (40.12 in)
R1039 mm (40.91 in)
max 90
Sling arrangement
Overall dimensions with open door(s) + door opening clearances
7/26/2019 Catalog Po Ak 2015
29/38A-28
.06
06-LL--110231-480 Variable speed drive
Application
Triol AK06 variable speed drive with 6-pulse input and ltered PWM output, IP43enclosure type (outdoors, cold climate), 480 V, oers enhanced motor performance,reliability and system integration options for linear motor control ESPs.
Rated voltage
Ratedinput
voltage,V
Rated current ofpower circuit, A
Rated powerof motor, kW
Rated powerof motor, hp
Catalog number
480
250 200 271.92 06-LL-250-110231-480
320 265 360.29 06-LL-320-110231-480
400 330 448.67 06-LL-400-110231-480
500 415 564.23 06-LL-500-110231-480
630 520 706.99 06-LL-630-110231-480
800 660 897.34 06-LL-800-110231-480
1000 830 1128.47 06-LL-10-110231-480
1200 995 1352.80 06-LL-12-110231-480
1400 1160 1577.14 06-LL-14-110231-480
1600 1330 1808.27 06-LL-16-110231-480
1800 1495 2032.60 06-LL-18-110231-480
7/26/2019 Catalog Po Ak 2015
30/38A-29
A.06
Keyfunctions
Motor switching on/o; Motor operation in the following modes: Manual without automatic restart after
a trip), Automatic with automatic restart after a trip, and Automatic with operationaccording to preset timing diagram;
Current optimization mode on reaching a preset value of the motor frequency; Manual control of motor speed from UMKA-03 controller and remote control froma dispatching point;
Automatic change of the output frequency according to a preset timing diagram; Motor automatic starting after selectable delay when the supply voltage is applied; Automatic maintaining of some process parameters (pressure, current) at their setpoints; Measurement and indication of current parameters of submersible pump and VSD on
the integrated liquid-crystal display; Motor remote control, monitoring of motor parameters, uploading and downloading of
protection settings through telemetering system (downhole measured equipment) viaRS485 interface;
Recording of trip events and corresponding current parameters into the integratednonvolatile memory;
Recording of modied settings into the event log with date and time corresponding tosuch modication;
Outdoor light alarm system indicating the pumping unit condition (run, wait, stop); Motor control with feedback from a submersible transducer; Congurable integrated protections: overload/underload, current imbalance, supply
voltage and DC-link voltage outside allowable limits, continuous operation at lowfrequency, power semiconductor overheating, operation at abnormal values ofparameters controlled by telemetering system (downhole);
Monitoring of input phase voltages. The drive is tripped or motor start is inhibited ifphase-loss condition is detected.
7/26/2019 Catalog Po Ak 2015
31/38A-30
.06
06-LL--110231-480 Variable speed drive
Technical characteristicsMain characteristics
Voltage, V 480 +10, -10%
Frequency, Hz 50 ... 60Eciency, % 97
Overload capability 125 % of the rated current for 300 seconds
Rectication type Half-controlled six-pulse (Graetz bridge)
Analog inputs 2
Digital inputs (opto-isolated,220 V a.c.)
2
Enclosure NEMA3 NEMA4X
Operation temperature -10 ... +60 / 14 ... 140F
Relative humiditynot more than 80 % at +20C(without condensation)
Altitude up to 1000 m / 3280 ft
StandardsNEMA 250-2008, GOST 17516,1-90,GOST 18058-80, GOST 15150-69,
Protection functions
Alarms and protections
tripping in case of supply voltage deviation if suchdeviation results in overcurrent condition
(with possibility of auto-restart after voltage)overcurrent protection (OCP)
IGBT de-saturation protection
protection against current imbalance
motor overload protection
7/26/2019 Catalog Po Ak 2015
32/38A-31
A.06
External connection diagram
Normally closed contacts
ESP on
ESP gen.
ESP off
+24 V +24 V
Control of ESM operation
Power supply of discrete inputs
Pressure Gauge Contact pressure gauge Digital input, contact pressure gauge
Ainput 1 Analog input 1
Ainput gen. General analog input
Ainput 2 Analog input 2Connection sensors of
submersible telemetry unit
ACS RS485 A+
ACS RS485 B-
Signal cable A RS485
Signal cable B RS485Connecting the external ACS
by RS-485ACS RS GND Neutral wire RS-485
Circuit Description Purpose
Casing ACVOT ESM
GroundingGND
Input3480V
thereduction
ofpowertransformer
A
B
C
Circuit diagram
2
2
1
3
2
1
3
2
1
3
2
1
3
6
4
5
3
1
TA1
TA2
Power switchQF1
X1 Socket
Circuit
220V AC
220V AC
1
2
Terminal of external connections
X5
X3
ESMON
ESM
common
ESMOFF
+24V
Cont.pres.gauge
Extern
alblocking
Ain1
Ain2
Ain
common
ACS
RS485A+
ACS
RS485B
ACS
RSGND
Circu
it
1 2 3 4 5 6 7 8 9 10
11
12
Contact pressure gauge
TMS terminal (downhole sensors)
1 2 3 4 5 6 7 8 9 10
11
12
TMS
RS485A+
TMSRS485B-
TMS
RSGND
TM
STXD
TM
SRXD
TM
SGND
Ain1
Ain2
Aincommon
220VAC
220VAC
C
ircu
it
Casing
Casing
Step-uptransformer
Output W
Output V
Output V
Output terminals
Phase A
Phase B
Phase C
Inputterminals
TA3
7/26/2019 Catalog Po Ak 2015
33/38A-32
.06
06-LL--110231-480 Variable speed drive
4 holes
1887mm(
74.2
9in)
887 mm (34.92 in) 815 mm (32.09 in)
14 mm (0.551 in)
606 mm (23.86 in)
500mm(
19.6
9in)
External connections compartment Intput connection panel
Output connection panel
Terminal
of step-up transformer connection
1208mm(
47.5
6in)
1255mm(
49.4
1in)
1208mm(
47.5
6in)
Dimensions
Height of cable connection points
7/26/2019 Catalog Po Ak 2015
34/38A-33
A.06
R743 mm (29.25 in)
R200 mm (7.87 in)
R755 mm (29.72 in)
R237 mm
(9.33 in)
1512 mm (59.53 in)
1966mm(
77.4
0in)
< 90
Sling arrangement
Overall dimensions with open door(s) + door opening clearances
7/26/2019 Catalog Po Ak 2015
35/38N-34
N.I
Optional equipment
GSM modem Triol MT01 providing remote control of the VSD (for more details visit ourwebsite www.triolcorp.com);
Modem Fargo Maestro or any other modem that provides data exchange with the variablespeed drive via GSM protocol;
Energy meters with RS-485; Ethernet communication unit; Safety shutdown feature (+ emergency o button). If the supply voltage disappears
or falls below the limit (or if the emergency stop button is pressed) the VSD will beautomatically turned o;
Uninterruptible power supply providing power for the controller for 24 hours aftera power failure. This simplies diagnostics of the VSD (determination of failure time,VSD behavior before the event, etc.);
Communication protocols for SCADAs Triol, Region, Telescope, and Salym Pet.
Package contents
The NEMA type drives Triol 01, 02, and 06 are supplied with the following items: Lock keys; Hardware kit for telemetering;
USB Flesh memory.
VSD can be supplied with the following items (optional): Spare parts including:
invertor unit rectier unit supply unit
Higher-level / lower-level controllers; Reduction Power Transformers; Fuses, with accordance to VSD rated voltage and current;
Invertor fans; Power switches; Modem kit with GSM-antennas and connection sockets; Electrical conduits for cabling in places of process facilities; Interfaces protection devices, used under pulse overloads and distortions; other equipment items, according to the Supply contract.
7/26/2019 Catalog Po Ak 2015
36/38N-35
N.I
Operation with downhole sensors
The NEMA type drives Triol 01, 02, and 06 provide operation with the followingdownhole sensors:
Triol Triol TMT produced by Triol Corporation; Borets produced by Borets LLC;
Electon produced by Electon; Izhevsk produced by JSC Izhevsk radio manufacturing plant; WoodGroup Smartguard produced by Woodgroup; Phoenix Phoenix produced by REDA (Shlumberger); SKAD-2002 SKAD-2002 produced by BelNipineft; Novomet produced by Novomet.
Installation of the surface units for the sensors can be done both inside and outsidethe VSD. Reception and transmission of data is carried out by means of protocols RS-232or RS-485. Supply voltage for the downhole units is 220 V.
Operation with SCADA
The NEMA type drives Triol 01, 02, and 06 can be interfaced to SCADA. Data istransmitted over the RS-485 protocol. Automatic tuning of communication is possible forthe following protocols:
Triol setting of communication channel for Triol protocol; Region communication channel for Region 2000 protocol; Telescope communication channel for Telescope protocol; Salym Pet communication channel for Salym protocol.
With the protocol Modbus RTU it is possible to communicate with the dispatchingstation.
The NEMA type drives Triol 01, 02, and 06 can be provided with custom digitaland analog inputs for connecting various sensors.
7/26/2019 Catalog Po Ak 2015
37/3836
S
Services
Triol Corporation is a leading developer and manufacturer of electric equipment. Thatswhy it pays considerable attention to service support of the products oered. We conducttrainings for maintenance personnel of our Customers and Partners.
Triol Corporations service support is carried out in collaboration with our Partners andincludes:
Warranty repair and spare parts; Post-warranty repair and spare parts; Diagnosis and Troubleshooting; Online Technical support ; Site inspection; Preventative service;
Personnel trainings.
We have spare parts warehouse and service support through our partners. It allows usto immediately respond to your requests and allows our Partners and Customers to feelcondent in the future.
7/26/2019 Catalog Po Ak 2015
38/38
S
Supporting documentation
Supporting documents include: Registration certicate. It includes main information, technical details of the product,
information about resources, lifetime and storage periods, manufacturer warranty;data about the delivery set; packing and reception certicates; product service record,notes on maintenance and storage; details about utilization and reclamation; specialnotes;
Operation manual contains information about the installation, operation and tech-nical parameters of variable speed drive Triol AK.
We can oer you a specialized Service software for getting, archiving and handling datafrom the well. It allows to analyze the event log on more than 50 indicators of the wellbehavior. The information is available both in graphic form and in Excel charts for dataexchange convenience. Combination of service software and Triol MT01 allows imple-
menting wells supervision.You can download up to date manuals and service software on our website
www.triolcorp.com in sections Technical documents and Software.