69
Chương 1 Giới thiệu Chương 2 Sub-rack and Boards Chapter 3 Đặc điểm

Cau Truc Phan Cung Va Dac Diem Thiet Bi OSN2500

  • Upload
    khucth

  • View
    240

  • Download
    11

Embed Size (px)

Citation preview

  • Chng 1 Gii thiuChng 2 Sub-rack and BoardsChapter 3 c im

  • OSN 2500 l g ?Gii thiu- Tn y : OptiX OSN 2500 intelligent optical switching system- H thng chuyn mch truy cp hay hi t quang.

  • iManager T2000

    OptiX BWS 1600GOSN 9500/7500/3500OSN 9500/7500/3500OSN /1500OSN 9500/7500160 10G4010G

    10G/2.5G

    OptiX BWS 1600GOSN 3500/OSN 3500/

    OSN 1500/MetroOSN /MetroOSN 1500/Metro10G/2.5G10G2500250025002500ng dng mngTruy cpHi tLiTrc

  • n v kt ni cho Ma trn bc cao (VC-4) Ma trn bc thp(VC-12/VC-3)LULUTULULUTUn v nh thin v ph trn v SCCTUTUEthernetPDHSANATMSDHSDHSDHSDHKin trc h thngKin trc h thng ca OptiX 2500Giao din qun lGiao din ph trGiao din ng b ngoi

  • Kh nng truy cp rng v a dch v

    Large-Capacity and Multi-Granularity Cross-Connect Capacity

  • Chng 1 Gii thiu sn phm

    Chng 2 Sub-rack and Boards

    Chapter 3 c im

  • Sub-rack

  • Sub-rack

    6 1, 2 7 3, 412 15,1613 17,18 SLOT3SLOT2SLOT1SLOT4Fiber routing panelSLOT 22PIUSLOT 25PIUSLOT 23FANSLOT 24FANSLOT17SLOT16SLOT15SLOT18

    SLOT8

    SLOT9

    SLOT10

    SLOT11

    SLOT12

    SLOT13

    SLOT14

    SLOT5

    SLOT6

    SLOT7

    Phn b slot v mi lin quan

  • Sub-rack

    Kh nng truy cp ca slot

  • Sub-rackKh nng truy cp ca slot

  • 1. SDH unit2. PDH unit3. Ethernet unit4. ATM unit5. WDM unit6. Cross-connect, Timing, SCC & Line unit7. Auxiliary unit

  • n v SDHCc boards x l SDH

    Board Tn y Slots cmLai giao dinV tr ng rau kt niSF16Board giao din quang STM-16 (vi chc nng FEC)Slot 7,8,11,12Ng ra bc sng c nh, Ue-16.2cUe-16.2dUe-16.2e Mt trc cardLCSL16Board giao din quang STM-16Ng ra bc sng c nh, I-16, S-16.1, L-16.1, L-16.2, L-16.2Je, V-16.2Je , U-16.2JeSLQ4Board giao din quang 4 x STM-4I-4, S-4.1, L-4.1, L-4.2, Ve-4.2SLD4Board giao din quang 2 x STM-4Slot 7,8,11-13SL4Board giao din quang STM-4Slot 5-8,11-13SLT1Board giao din quang 12 x STM-1I-1, S-1.1, L-1.1, L-1.2, Ve-1.2SLQ1Board giao din quang 4 x STM-1SL1Board giao din quang STM-1

  • n v SDHThe SDH processing boards

    Board Tn y Slots cmLai giao dinV tr ng rau kt niR1SLD4Board giao din quang 2 x STM-4Slot 7,21I-4, S-4.1, L-4.1, L-4.2, Ve-4.2Mt trc cardLCR1SL4Board giao din quang STM-4Slot 5~7,19~21R1SLQ1Board giao din quang 4 x STM-1I-1, S-1.1, L-1.1, L-1.2, Ve-1.2R1SL1Board giao din quang STM-1

  • n v SDH

    Board Tn y Slots cmLai giao dinV tr ng rau kt niSEP1Board giao din quang STM-1Slot 5-8,11-1375 STM-1 giao din inMt trc cardSMBSEPBoard giao din quang STM-1Slot 6,7,12,13giao din quang I-1, S-1.1 v giao din in 75 STM-1Board giao dinLC, SC v SMB

    Board Tn y Slots cmu kt niBoard x lEU08Board giao din in 8 x STM-1Slot 1,3,15,17SMBSEPOU08Board giao din quang 8 x STM-1LCEU04Board giao din in 4 x STM-1SMB

  • n v SDH16 X VC4Chc nng ca n v SDH (ly card SL16 lm v d)

  • n v SDHNg ra bc sng c nh Chc nng tt cng sut quang t ngModule quang c th chuyn iH tr ccdch v AU-4-4c, AU-4-16cChc nng inloop v outloop

    c im ca n v SDH

  • n v SDHCc thng s port quang SL16

    Loi giao din quangI-16S-16.1L-16.1L-16.2L-16.2JeV-16.2Je (BA)U-16.2Je (BA+PA)Bc sng (nm)1310131013101550155015501550.12Khong cch truyn (km)02215154040808010080140140170Cng sut phng (dBm)-10-3-50-23-23571414 nhy thu (dBm)-18-18-27-28-28-28-33Qu ti u thu (dBm)-30-9-9-9-9-10

  • n v SDH

  • n v SDH

  • n v SDH

  • n v SDHSEP1Khng c board giao dinC 2 giao din in STM1 pha trc.

    SEPCn c board giao din ,v d: EU08, OU08, EU042 giao din in trn mt th khng th s dng.

  • n v SDH

  • 1. SDH unit2. PDH unit3. Ethernet unit4. ATM unit5. WDM unit6. Cross-connect, Timing, SCC & Line unit7. Auxiliary unit

  • PDH UnitCc board x l PDH

    Board Tn y Slots cmu kt ni SPQ44 x E4/STM-1 processing board slot 6,7,12,13SMBPD36 x E3/DS3 processing board slot 6,7,12,13SMBPL33 x E3/DS3 processing board slot 6,7,12,13SMBPQ163 x E1 processing board slot 5,6,7,12,13 DB44PQM63 x T1/E1 processing board slot 5,6,7,12,13 DB44

  • n v PDHCc board chuyn mch v giao din PDH

    Board Tn y Slots cm u kt ni Dng viMU04Board giao din in 4 x E4/STM-1slot 1,3,15,17SMBSPQ4TSB8Board bt cu v chuyn mch 8 giao dinslot 1,17NoneD34S, C34S v PD3, PL3TSB4Board bt cu v chuyn mch 4 giao dinslot 1,17NoneC34S v PL3D34SBoard chuyn mch giao din PDH 6 x E3/DS3slot 1,3,15,17SMBPD3C34SBoard chuyn mch giao din PDH 3 x E3/DS3slot 1,3,15,17SMBPL3D75SBoard chuyn mch giao din E1 32 x 75 slot 1-4,15,18DB44PQ1D12SBoard chuyn mch giao din 32 x 120 E1/100 T1slot 1-4,15,18DB44PQ1, PQMD12BBoard giao din in 32 x E1/T1slot 1-4,15,18DB44PQ1, PQM

  • n v PDHVC463 X E1Chc nng ca n v PDH (ly PQ1 lm v d)

  • n v PDHLoi giao din75 or 120Chc nng inloop v outloopReset cng v mmChc nng TPS

  • n v PDH PQ1, PQM/D75S, D12S, D12B

  • n v PDH PL3/C34S, PD3/D34S

  • n v PDH SPQ4/MU04

  • 1. SDH unit2. PDH unit3. Ethernet unit4. ATM unit5. WDM unit6. Cross-connect, Timing, SCC & Line unit 7. Auxiliary unit

  • n v Ethernet

    Board Tn y Slot cmV tr ng raLoi giao dinu niEFS4Board x l 4-port 10/100 Mbit/s fast Ethernet vi chc nng chuyn mchSlot 5-8,11-13Mt trc card10/100BASE-TXRJ-45EGR22-port Gigabit Ethernet RPR boardMt trc card1000BASE-SX/LX/ZXLCEFS0Board x l fast Ethernet vi chc nng chuyn mchSlot 6,7,12,13Board giao din10/100BASE-TXRJ-45EMR0Board x l RPR 12 port in 10/100 Mbit/s v 1 port quang 1Gbit/sSlot 5-8,11-13Board giao din v mt trc card10/100BASE-TX, 1000BASE-SX/LX/ZXRJ-45, LC

    Board Tn y Slot cmu niBoard x lETF8Board giao din in Ethernet 8 port 10/100 Mbit/sSlot 1,3,15,17RJ-45EFS0,EMR0,EFT8EFF8Board giao din quang Ethernet 8 port 100 Mbit/sLCETS8Board giao din vi chc nng bt cu 8 FERJ-45EFS0,EMR0

  • n v Ethernet

    Board Tn y Slot cmV tr ng raLoi giao dinu niEGS2Board x l chuyn mch 2-port Gigabit EthernetSlot 5-8,11-13Mt trc card1000BASE-SX/LX/ZXLCEGT2Board truyn trong sut 2-port Gigabit EthernetMt trc card1000BASE-SX/LX/ZXLCEFT4Board truyn trong sut 4-port 100 Mbit/s Fast Ethernet. (card na) Slot 5-7,19-21Mt trc card10Base-T/100Base-TXRJ-45EFT8Board truyn trong sut 8/16-port 100 Mbit/s Fast EthernetSlot 5-8,11-13Board giao din v mt trc card10Base-T/100Base-TX100Base-FXRJ-45, LC

    Board Tn y Slot cmu niBoard x lETF8Board giao din in Ethernet 8 port 10/100 Mbit/sSlot 1,3,15,17RJ-45EFS0,EMR0,EFT8EFF8Board giao din quang Ethernet 8 port 100 Mbit/sLC

  • 4 X FE4X VC4FEn v EthernetChc nng ca n v Ethernet (Ly EFS4 lm v d)

    Only the 4th VC4 can be binded at VC12 level.

  • u ni:RJ-45: 100mLC: 15 km(single mode fiber), 2km( multi-mode fiber)H tr chc nng auto- negotiationH tr cc dch v EPL/EPLAN/EVPL/EVPLAN v QoSCc khung 64 bytes-9600 bytes

    n v Ethernet

  • n v Ethernet

  • 1. SDH unit2. PDH unit3. Ethernet unit4. ATM unit5. WDM unit6. Cross-connect, Timing, SCC & Line unit7. Auxiliary unit

  • Nhng boards x l ATMn v ATM

    BoardTn y Slot cmV tr ng raLoi giao dinu niADL4Board x l 1 x STM-4 ATMSlot 7,8,11-13Mt trc cardS-4.1,L-4.1LCADQ1Board x l 4 x STM-1 ATMI-1,S-1.1,L-1.1

  • 4 X ATM8X VC4ATMn v ATMChc nng ca n v ATM (ly ADQ1 lm v d

  • n v ATM- H tr S-4.1 and L-4.1, I-1, S-1.1 and L-1.1- H tr QoS- Kh nng chuyn mch ATM 1.25 Gbit/s

  • n v ATM

  • 1. SDH unit2. PDH unit3. Ethernet unit4. ATM unit5. WDM unit6. Cross-connect Timing, SCC & Line unit 7. Auxiliary unit

  • n v WDM

    Board Tn y Slot cmV tr ng rau niLWXn v chuyn i bc sng tc bt kSlot 5-8,11-13Mt trc cardLCMR2ABoard ghp add/drop quang 2 knhMR2BSlot 5-6,19-21MR2C Slot 1-4,15-18

  • n v WDMLWXLWXLWXOChSDHPDHFE ATMFICONFC

    SDHPDHFE ATMFICONFC

  • n v WDMLWX

    Giao dinLoiDin tIN/IN1/IN2LCNhn nhng tn hiu t board ghp add/drop MR2AOUT/OUT1/OUT2Gi tn hiu ti board ghp add/drop MR2A TXGi tn hiu dch v ti thit b pha khch hngRXNhn tn hiu t pha khch hng.

  • n v WDMLWX

    Loi boardBo vDin tLWX chn la tn hiu dual-fed Bo v ngoi board Bo v knh quang vi mt board LWX chn la tn hiu single-fed Bo v trong board Bo v hot backup 1+1 trong board

  • WDM UnitMR2A/MR2C

    Giao dinLoiDin t A01A02LCTruy sut hai knh ca tn hiu dch v c cng voD01D02Rt hai knh ca tn hiu dch v cc bINNhn hai knh ca tn hiu ghpOUTGi hai knh ca tn hiu ghpMO/MIGiao din kt ni, qua cc boards MR2A/MR2C c th c kt ni vi nhau

  • WDM UnitMR2A/MR2C

  • 1. SDH unit2. PDH unit3. Ethernet unit4. ATM unit5. MST unit6. WDM unit7. Cross connect, Timing, SCC & Line unit8. Auxiliary unit

  • High-order cross-connect matrix (20G)SDH unitEthernet unitPDH unitLow-order cross-connect matrix (5G)n v kt ni cho

    GXCH A single board supports a cross-connect capacity of 200 G, and a single sub-rack, 400 G Implements flexible service grooming at VC-4 granularity, including loopback, cross-connect, multicast and broadcast.Be used in slot XCH.Supports the 1+1 protection at board levelBinding protection scheme of both the upper and lower framesCommunication with JSCC

  • 2.5G line unitPDH unitStandby2.5G line unitEthernet unitPDH unitEthernet unit2.5G line unit2.5G line unitCross-connectCross-connectActiven v kt ni cho

  • SDH unitEthernet unitPDH unitCross-connect unitOther NEDCCn v thng tin v iu khin h thngChc nng n v SCC

  • n v thng tin v iu khin h thngChc nng n v SCCCu hnh dch vCi t NE ID bng phn mm1+1 hot backupiu khin ch th cabinet v qut

  • n v thng tin v iu khin h thng

  • 1. SDH unit2. PDH unit3. Ethernet unit4. ATM unit5. MST unit6. WDM unit7. Cross-connect, Timing, SCC & Line unit8. Auxiliary unit

  • n v ph tr

    No.Board Board name1System Auxiliary ProcessSAP2System Extended InterfaceSEI 3Power Interface BoardPIU4Booster Amplifier BoardBA25Pre-amplifier BoardBPA6Uninterruptible Power Modules UPM7Fan unitFANA

  • Board x l ph tr h thng - SAPChc nng: - Cung cp thng tin lin board - Cung cp chc nng backup tp trung ngun +3.3 V - X l orderwire bytes - Gim st ngun ng vo mt cch c lp.

  • NM portCOM test portBoard x l ph tr h thng - SAP

  • Power Interface BoardPIU

    Chc nng:Truy xut ngun Bo v rt nhanh Bo v giao din ngun t nhng nguy him gy bi kt ni sai Bo v backup 1+1.

    JCOMImplements communication of the control information between the JSCC and other relevant boards in the sub-rack.Supports hot swapping of the boards.Monitoring and protection of the MBUS.Provides debug network port.

  • Power Interface BoardPIU

    Giao dinDin tPWSGiao din ng ra cng sut 50 W, ngun cung cp cho COA or HUBPWRGiao din truy sut 48 V

  • Booster Amplifier BoardBA2

  • Booster Amplifier BoardBA2

    c dng u phtCng sut quang ng ra c nhThng tin c v cc thng s performanceChc nng ALS

  • Booster Amplifier BoardBA2 c tnh

    No. Cng sut ng ra ca port 1 (dbm)Cng sut ng ra ca port 2 (dbm)114Null 217Null 314144171751417

  • Pre-amplifier BoardBPATxRx

  • Pre-amplifier BoardBPAc tnh

    No. Cng sut ng ra ca port 1 (dbm) li port 2(db)1142221722

  • Pre-amplifier BoardBPA

    Ci thin nhy thu ti -38 dBm Dng u thu Chc nng ALS Thng tin c v cc thng s performance

  • Chapter 1 Product IntroductionChapter 2 Sub-rack and BoardsChapter 3 Features

  • Equipment Protection1:4 TPS of E1/T1 board2 groups of 1:1 TPS of E3/DS3/E4/STM-1(e) board

    Items protectedProtection schemeE1/T1 processing card1:N (N 4) TPSE3/DS3 processing card1:1 TPSE4/STM-1 processing card1:1 TPSCore unit1+1 hot backup protection-48V power interface card1+1 hot backup protection3.3V card power supply1:N centralized hot backup protection* The OptiX OSN 2500 can support two TPS groups of different types of services at the one time.

    SLOT1

    SLOT2

    SLOT3

    SLOT4

    SLOT5

    SLOT6

    SLOT7

    SLOT8

    XC+SCC+LC

    SLOT16

    SLOT11

    SLOT12

    SLOT13

    Working

    LAN&PMU&EOW

    SLOT16

    SLOT17

    SLOT18

    Working

    Working

    XC+SCC+LC

    Protection

    Working

    The OptiX OSN 2500 provides 1:N TPS protection for the PD1, PQ1, PQM, PL3, PD3, SPQ4, SEP1 and EFS0 boards. That is, it provides TPS protection for the E1, T1, E3, DS3, E4, STM-1 and Ethernet services.E1 processing board PD1 supports two 1:N (N2) TPS protection groupsE1 processing board PQ1 supports one 1:N (N4) TPS protection group.E1/T1 processing board PQM supports one 1:N (N4) TPS protection group.E3/T3 processing board PD3/PL3 supports two 1:1 TPS protection groups.E4/STM-1 processing board SPQ4 supports two 1:1 TPS protection groups.STM-1 processing board SEP1 supports two 1:1 TPS protection groups.Ethernet processing board EFS0 supports two 1:1 TPS protection groups.Co-existence of the above two different TPS protection groupsThe signal failure time is less than 50ms in TPS switching.

  • Network Level Protections

    ProtectionsTypesLinear MSP1+1 MSP1:N (1 N 14) MSPMSP ring2-fiber bidirectional MSP ring2-fiber unidirectional MSP ring4-fiber bidirectional MSP ringMesh ProtectionIntelligent functionSNCPDual node interconnection (DNI)Fiber-Shared Virtual Path ProtectionMS-Shared Optical Path ProtectionRPRVP-Ring/VC-Ring Protection

    Large-Capacity and Multi-Granularity Cross-Connect Capacity

    Only the 4th VC4 can be binded at VC12 level.

    GXCH A single board supports a cross-connect capacity of 200 G, and a single sub-rack, 400 G Implements flexible service grooming at VC-4 granularity, including loopback, cross-connect, multicast and broadcast.Be used in slot XCH.Supports the 1+1 protection at board levelBinding protection scheme of both the upper and lower framesCommunication with JSCC

    JCOMImplements communication of the control information between the JSCC and other relevant boards in the sub-rack.Supports hot swapping of the boards.Monitoring and protection of the MBUS.Provides debug network port. The OptiX OSN 2500 provides 1:N TPS protection for the PD1, PQ1, PQM, PL3, PD3, SPQ4, SEP1 and EFS0 boards. That is, it provides TPS protection for the E1, T1, E3, DS3, E4, STM-1 and Ethernet services.E1 processing board PD1 supports two 1:N (N2) TPS protection groupsE1 processing board PQ1 supports one 1:N (N4) TPS protection group.E1/T1 processing board PQM supports one 1:N (N4) TPS protection group.E3/T3 processing board PD3/PL3 supports two 1:1 TPS protection groups.E4/STM-1 processing board SPQ4 supports two 1:1 TPS protection groups.STM-1 processing board SEP1 supports two 1:1 TPS protection groups.Ethernet processing board EFS0 supports two 1:1 TPS protection groups.Co-existence of the above two different TPS protection groupsThe signal failure time is less than 50ms in TPS switching.