Chilicote catálogo

  • Upload
    risegra

  • View
    216

  • Download
    0

Embed Size (px)

Citation preview

  • 8/13/2019 Chilicote catlogo

    1/10w w w . f m c s y n t r o n . c o mMaterial Handling Solutions

    A 20-inch wide Coilmount conveyor handling wood chips. Installedon upper floor of building, the conveyor has a spring mounted andcounterweighted base to isolate vibration from building structure.

    Syntron Coilmount Oscillating Conveyors are ideally suited toconvey a variety of materials including granular, free-flowingmaterials, fragile or sticky materials, and abra-

    sive materials such as ores, sand,castings and scrap metal.

    Coilmount Vibrating Conveyors

    Coilmount vibrating conveyors

    Ruggedly constructed to providereliable and economical service,the units can also be modified tosuit specific scalping, cooling, heat-ing and drying processes. TheCoilmount handles large capacitiesof low- to high-density materials.

    Coilmount conveyors can bequickly and easily installed onconcrete foundations or on struc-tures near grade level. These con-veyors are available in standardsizes of 10-inch and 20-inch widthswith 6-inch deep troughs. A 12-inch deep trough is also available.Coilmount conveyors are con-structed of either 10 gauge or3/16-inch mild or stainless steel. Inaddition, flanged troughs can be

    made of special materials. A vari-ety of liner materials are availablefor handling corrosive or abrasivematerials. Troughs can also be fur-nished with covers which attachwith bolts or quick-acting fasten-ers. Installing gaskets between thecover and trough creates a seal fordust-tight or weather-tight applica-tions. Inlet spouts and exhaustvents can also be provided to meet

    specific conveying processes.

    Type A Coilmount

    Type B Coilmount

  • 8/13/2019 Chilicote catlogo

    2/10

    2

    Type A and B Coilmount

    trough assemblyThe conveyor trough is supportedby rubber-bushed aluminum stabi-

    lizer legs. Heavy-duty coil springsare used as a restoring energy sys-tem, providing reduced powerconsumption at operating speed.Single-spring reactor systems arefurnished for 10-inch widths, anddouble-spring reactor systems areused on 20-inch widths.

    Coilmount trough assembly and positive drive

    Type A Coilmount single springreactor system.

    Type A Coilmount Positive Drive Arrangement (Illustrationdepicts optional end drive).

    Type A Coilmount positive drive.

    Type B Coilmount troughand spring reactor system.

    Type B Coilmount positive drive.

    Type A and B Coilmountdrive

    The Coilmount conveyors positivedrive system has heavy-duty spheri-cal roller bearings, a cast steel con-necting arm, and a rubber-bushedor bronze wrist pin assembly,which is securely locked to the con-veyor pan with taper lock bushings.This drive system maintains posi-tive action regardless of load condi-tions. Drives are positioned eitherat the conveyor feed end as an end

    drive or along the conveyor lengthas an intermediate drive.

    For the intermediate drive, option-al motor and motor supports areindependent of the conveyor baseand can be purchased with the unit.Motors for intermediate drives canbe mounted on either the left-handor right-hand side of the conveyor.

    Type A Coilmount single drivefor conveyor model 2500.

    Type A Coilmount double drivefor conveyor model 3500.

    Key

    Type A Coilmount conveyors feature single-arm drives for 10-inch trough widths.Double-arm drives are furnished on 20-inchwide Type A conveyors.

  • 8/13/2019 Chilicote catlogo

    3/10w w w . f m c s y n t r o n . c o mMaterial Handling Solutions

    3

    Description

    Includes drive base, shear bars, eccentric drive, V-belt drive with

    guard, bolts and nuts for connecting to conveyor section, and a 2-foot long section of trough. Optional motor and motor starterare purchased separately.

    Subassembly

    FEED END DRIVE ASSEMBLY

    5-FOOT INTERMEDIATE DRIVE SECTION

    5-FOOT PRIMARY SECTION

    10-FOOT PRIMARY SECTION

    10-FOOT SUPPLEMENTARY SECTION

    TRANSFER SECTION

    DISCHARGE EXTENSION

    TROUGH COVER

    Typically located anywhere in conveyor, preferably at center.Includes drive base, shear bars, eccentric drive, 5-foot troughassembly, V-belt drive with guard, rocker legs and necessary boltsand nuts for connecting to conveyor trough section. Optionalmotor and motor starter are purchased separately.

    Includes trough, base, 2 sets of Coilmount reactor springs andnecessary bolts and nuts for connection to drive assembly oradjacent sections.

    Includes trough, base, 3 sets of Coilmount reactor springs andnecessary bolts and nuts for connection to end drive assemblyor adjacent sections.

    Includes trough, base, 2 sets of Coilmount reactor springs andnecessary bolts and nuts for connection to drive assembly oradjacent sections.

    Includes discharge and feed extensions. Required bolts andnuts included.

    Used to extend discharge beyond base. Required bolts andnuts included. Standard length is 12-inches. Maximumlength of 24-inches is available.

    Used for dust-tight applications. Provided in 5-footsections. Required clamps or bolts for attachment to stan-dard trough section and sponge rubber gasket are included.

    Coilmount positive driveType A Coilmount components,capacities and dimensions

    Type A Coilmount Conveyor Components

  • 8/13/2019 Chilicote catlogo

    4/10

  • 8/13/2019 Chilicote catlogo

    5/10w w w . f m c s y n t r o n . c o mMaterial Handling Solutions

    5

    Trough size Inches

    Width/DepthHorsepower

    A B C D

    10 x 6 1 and 2 26 1/2 10 3/8 10 5/8 12 1/4

    10 x 12 3 and 5 261

    /2 117

    /8 105

    /8 121

    /4

    20 x 6 1 and 2 30 5/8 14 1/2 14 3/4 16 3/8

    20 x 12 3 and 5 30 5/8 16 14 3/4 16 3/8

    Certify all dimensions for installation purposes.Dimensions in inches.

    CL

    Type A Coilmount components,capacities and dimensions, contd.

    5-Foot Feed End Drive Section

    Transfer Section, 5-Foot Primary Section and 5-Foot Intermediate Drive Section

    To determine conveyor requirements, please refer toboth the chart and dimensional illustrations on this pageand the following page.

    Type A Coilmount Conveyor Dimensions

    Base-mounted, non-isolated Flexmount and Coilmountconveyors must be mounted on a concrete foundation

    at grade level that is suitable to withstand the dynamicloads exerted. Please contact FMC Technologies to

    confirm actual recommended foundation requirements.

  • 8/13/2019 Chilicote catlogo

    6/10

    6

    8

    CL

    CL

    CL

    10-Foot Supplementary or Primary Section

    Trough Width and Depth

    Coilmount conveyor handling redwood bark from a debarker to anotherCoilmount transfer conveyor.

  • 8/13/2019 Chilicote catlogo

    7/10w w w . f m c s y n t r o n . c o mMaterial Handling Solutions

    7

    Typically located anywhere in conveyor, preferably at center.

    Includes drive base, shear bars, eccentric drive, 10-foot troughassembly, V-belt drive with guard, rocker legs and necessarybolts and nuts for connecting to conveyor trough section.Optional motor and motor starter are purchased separately.

    Subassembly

    10-FOOT INTERMEDIATE DRIVE SECTION

    5-FOOT PRIMARY SECTION

    10-FOOT PRIMARY SECTION

    15-FOOT PRIMARY SECTION

    20-FOOT PRIMARY SECTION

    20-FOOT SUPPLEMENTARY SECTION

    TRANSFER SECTION

    DISCHARGE EXTENSION

    TROUGH COVER

    Typically located at feed end of conveyor. Includes trough, base, 2sets of Coilmount reactor springs and necessary nuts and bolts forconnection to drive assembly or adjacent sections.

    Typically located at feed end of conveyor when intermediate driveis used. Includes trough, base, 3 sets of Coilmount reactor springsand necessary nuts and bolts for connection to drive assembly oradjacent sections.

    Typically located at feed end of conveyor when intermediate drive

    is used. Includes trough, base, 2 sets of Coilmount reactor springsand necessary nuts and bolts for connection to drive assembly oradjacent sections.

    Typically located at feed end of conveyor when intermediate driveis used. Includes trough, base, 4 sets of Coilmount reactor springs

    and necessary nuts and bolts for connection to drive assembly oradjacent sections.

    Typically located anywhere in conveyor except at feed end. Includestrough, base, 3 sets of Coilmount reactor springs and necessarybolts and nuts for connection to drive assembly or adjacent sections.

    Used when connecting conveyors in line. Includes discharge andfeed extensions. Required bolts and nuts included.

    Used to extend discharge beyond base. Required bolts andnuts included. Standard length is 12-inches. Maximumlength of 24-inches is available.

    Used for dust-tight applications. Provided in 5-footsections. Required clamps or bolts for attachment to stan-dard trough section and sponge rubber gasket are included.

    Type B Coilmount Conveyor Components

    Description

    Coilmount positive driveType B Coilmount components,capacities and dimensions, contd.

  • 8/13/2019 Chilicote catlogo

    8/10

    8

    To determine the required material travel speed fromCapacity Chart E, intersect conveyor capacity in tons

    per hour with material weight in pounds per cubic foot.

    Type B Coilmount Conveyor Capacities

    To determine the correct motor horsepower fromDrive Selection Chart F, intersect conveyorcapacity in tons per hour with the required lengthof the conveyor.

    Coilmount conveyors can be installed at inclines of up to 15degrees, depending on the characteristics of the material beinghandled.

  • 8/13/2019 Chilicote catlogo

    9/10w w w . f m c s y n t r o n . c o mMaterial Handling Solutions

    9

    Trough width Inches

    inches (A) B C D E

    24 12 5/8 18 7/8 18 1/2 3730 15 5/8 21 7/8 21 1/2 40

    36 18 5/8 24 7/8 24 1/2 43

    42 21 5/8 27 7/8 27 1/2 46

    Certify all dimensions for installation purposes.Dimensions in inches.

    6 30 24

    2413/16

    68

    62

    E

    D

    C

    Transfer SectionConveyor Sections

    as Required

    Primary Section5-foot Section Shown 10-foot Section

    Conveyor Sectionsas Required

    58 6218

    12

    2 1/2

    Flow

    3

    12

    2 24

    33 26 21

    2

    28

    Shear Bars24

    12

    10-foot Primary Section

    Flow

    80 28

    Type B Coilmount components,capacities and dimensions, contd.

    Transfer Section, 5-Foot Primary Section and 5-Foot Intermediate Drive Section

    10-Foot Primary Section

    To determine conveyor requirements, please refer toboth the chart and dimensional illustrations on this page

    and the following page.

    Type B Coilmount Conveyor Dimensions

  • 8/13/2019 Chilicote catlogo

    10/10

    A

    6 4

    1215/16 NeutralDimension

    4

    B

    Trough Cross Section

    AllFoundationBolts 3/4-inch

    B

    15-Foot Primary Section

    Flow

    80 2812 60

    20-Foot Supplimentary Section

    Flow

    80 28

    12

    52

    Flow

    80

    Location of Foundation Bolts for 20- Foot Primary Sections

    20-Foot Primary Section

    Flow

    80 28

    12

    52

    Flow

    80

    Location of Foundation Bolts for 20- Foot Supplementary Sections

    15-Foot Primary Section

    20-Foot Primary Section

    20-Foot Supplementary Section

    Trough Width and Depth Base-mounted, non-isolated Flexmount andCoilmount conveyors must be mounted on aconcrete foundation at grade level that

    is suitable to withstand the dynamic loads

    exerted. Please contact FMC Technologiesto confirm actual recommended foundationrequirements.