16
ColorBlaze Industry-standard theatrical and rental LED batten with intelligent color light

ColorBlaze Product Guide

  • Upload
    buidieu

  • View
    215

  • Download
    0

Embed Size (px)

Citation preview

ColorBlazeIndustry-standard theatrical and rental LED batten with intelligent color light

ColorBlaze Product Guide2

• Twofixturelengths—Availableintwofixturelengths,ColorBlaze72(6ft,1.8m)andColorBlaze48(4ft,1.2m),eachcontrollablein6in(152mm)segments.

• Universal,integratedpowersupply—Auto-switchingpowersupplyacceptspowerinputof100–240VAC,eliminatingtheneedforadditionalequipmentandenablingconsistentusearoundtheworld.

• Pushbuttonaddressingandconfiguration—Onboardaddressingofferseasyconfigurationwithoutexternaladdressingtools.

• Industry-leadingcontrols—ColorBlazeworkswiththecompletePhilipslineofcontrollers,includingColorDialPro,iPlayer3,andLightSystemManager,aswellasthird-partycontrollers.Fixturescanbeconnectedinseriesofupto1,000ft(300m)usinganycombinationofRJ45,Ethercon,andXLR-5datacables.

• High-intensity,saturatedcoloroutput—RGBcolormixingprovides16.7millioncolorswithvariableintensity.Each6in(152mm)segmenthasanoutputofover450lumens.

• Simplelightpositioning—Mountingbracketsandlockingknobsenable180°rotation,adjustment,andlockingwithoutspecialtools.

• Versatilemountingoptionsandaccessories—Clamp-mountColorBlazetopipesortrusses,ormountdirectlytoasurface.AnoptionalT-handlemountingbracketisavailableforspecialmountingsituations.Accessoryholders,spreadlenses,andothercustomaccessoriesspecificallydesignedforColorBlazeareavailablefromCityTheatricalInc.

• Additionalstage-friendlyfeatures—Onboardcoolingfanandthermalsensorpreventoverheating.AfullrangeofreplacementpartsisavailabletokeepColorBlazefixturesinserviceforthelonghaul.

ColorBlaze Industry-standard theatrical and rental LED batten with intelligent color light

Flexible ConfigurationColorBlazefixturescanbeconfiguredtoworkinunisonorindependentlytodisplaydynamic,color-changingeffects.

Eachfixturecanbesettohaveoneormoreindividuallycontrollablesegments—upto8forColorBlaze48,andupto12forColorBlaze72.

ColorBlazeisarobust,high-performancelinearLEDfixtureforwashinglargeareaswithfar-reaching,rich,saturatedcolors.Witharugged,extrudedaluminumhousing,ColorBlazeisdesignedtowithstandtherigorsofthetouringandrentalmarket.Integratedpowersupplieseliminatetheneedforadditionalequipment,pushbuttonaddressingcapabilitiessimplifyconfigurationandinstallation,andlockingmountingbracketsallowforflexiblemountingtopipesorsurfaces,makingColorBlazeaneasy-to-useyetpowerfulsolutionfortheaters,TVstudios,concerts,events,casinos,andexhibits.Tosupportdynamic,color-changingeffects,eachColorBlazefixtureiscontrollablein6in(152mm)segments.

ColorBlaze Product Guide 3

Vibrant, Far-Reaching Color — AnywhereColorBlazeefficientlycastsfar-reachingcoloredlightandeffectswithsuperioroutputinboththeatricalandarchitecturalapplications.On-boardpowerandaddressing,streamlineddesign,ruggedaluminumhousing,andanextensivecomponentreplacementprogrammakeColorBlazeidealfortouringandrentalenvironments,wherefixturesmustwithstandrepeatedsetup,reconfiguration,andteardown.Thedurability,lowmaintenance,andintelligentcontrolaffordedbyindustry-leadingLEDtechnologyalsomakesColorBlazeidealforpermanentarchitecturalinstallations.

The Orange County Performing Arts Center Celebratory GalaWhilebestknownforlarge-areasceneryandwashlighting,ColorBlazecanbeeasilyconfiguredtodisplayspectacularvideoeffectsonmultipleindividuallycontrollablesegments.Suchwastheapproachofthedesignershiredin2006tocreatealightingschemeforthegalacelebratingthe20thanniversaryseasonoftheOrangeCountyPerformingArtsCenterandtheopeningofitsworld-classSegerstromConcertHall.

Thelightingschemeincorporatedbothdirect-viewvideoelementsandcomplementarywall-washingeffects.Thedirectvideolightingdisplay,mountedinverticalarraysagainstthevenue’sbackwall,includedcascadingwaterfallimageryandaspectacularsunseteffect,streamedtoColorBlazefixturesviaVideoSystemManager(VSM).

Thedesignalsocalledformorethan45ColorBlaze72fixturesalongthewallsofthetentinwhichthegalawasheld.NotonlyweretheseColorBlazefixturesusedtoprojectbold,saturatedcolorsagainstthewhiteinteriorsurfacesofthetent,theywerealsousedtoprojectdigitalvideocontent,streamedfromtheVSM,thatsuggestedflowingmovementstocoincidewiththedirect-viewdisplay.

Theentireprojectrequiredonly30daysfromconcepttocompletion.Becauseofthefixtures’easeofconfigurationandinstallation,thelightingsetupitselfwasdonevirtuallyovernight.

Photography: Nadine Froger

ColorBlaze Product Guide4

The DeVos Performance Hall RenovationThesummer2004renovationofDeVosPerformanceHall—a2,400-seatperformingartstheatreinGrandRapids,Michigan—showcasesColorBlazeinalandmarkarchitecturalsetting.

Theextensiveinternalrenovationsofthispopulartheatre,hometotheGrandRapidsSymphony,theGrandRapidsBalletCompany,BroadwayTheatreGuild,andmanytouringconcertsandfamilyshows,calledforcolorfulaccentlightingtoenliventhetheatre’ssidewalls.

Thelightingschemewasintendedtogivenewlifetothepreviouslygrayperimeterwalls,whichreachaheightof60ft(18m).Theownersdesiredanewlookthatwouldnotsimplyaccentuatethewalls,butthatwouldactuallychangetheperceptionoftheaudiencespace.Thenewtreatmenthadtobelarge-scale,readytobuild,easytomaintain,andcost-effective.Therenovationshadtobecompletedwithin90dayssoasnottointerferewiththeexistingproductionandperformanceschedule.

Approximately44ColorBlaze72fixturesweremountedtotheceilinginlinearrunsalongeachperimeterwalltouniformlywashtheirsurfaceswithsaturatedstaticcolorandsubtle,dynamicsequences.Theownersplacedahighvalueoncolor-changinglighting,becausethehallisusedformanydifferenttypesofproductions,fromoperaandballettopop/rockacts.Thedynamicsequencesincludesubtletwo-colorfades—orangetoamberandbluetoviolet,forexample—androllingrainbows

Theeffectsareeasilytriggeredbyasimplepresetrecallpanelinthecontrolroom.LightingboardoperatorscanalsodrivetheColorBlazefixturesthroughthetheatre’sDMXcontrolconsole.

Phot

ogra

phy:

Mar

k Tho

mas

Pro

duct

ions

, Ltd

.

ColorBlaze Product Guide 5

Center Beam fc Beam Width

3.0 ft

6.7 ft

10.0 ft

13.3 ft

16.7 ft

20.0 ft

6422 fc

1606 fc

714 fc

401 fc

257 fc

178 fc

0.6 ft

1.1 ft

1.7 ft

2.3 ft

2.9 ft

3.4 ft

0.6 ft

1.3 ft

1.9 ft

2.5 ft

3.1 ft

3.8 ft

�� Vert. Spread: 9.9º�� Horiz. Spread: 10.8º

Illuminance at DistanceColorBlaze48 Polar Candela Distribution

RCC %: Ceiling reflectance percentage, RW %: Wall reflectance percentage, RCR: Room cavity ratio

Effective Floor Cavity Reflectance: 20% RCC %: 80 70 50 30 10 0RW %:RCR: 0

123456789

10

70 50 30 01.19 1.19 1.19 1.191.15 1.13 1.11 1.101.12 1.08 1.05 1.031.08 1.04 1.00 .981.05 1.00 .97 .941.03 .97 .94 .911.00 .95 .91 .88

.98 .92 .89 .86

.96 .91 .87 .84

.95 .89 .85 .83

.93 .87 .84 .82

70 50 30 01.16 1.16 1.16 1.001.13 1.11 1.09 .971.09 1.06 1.04 .941.07 1.03 .99 .921.04 .99 .96 .901.01 .97 .93 .88

.99 .94 .91 .86

.97 .92 .88 .85

.95 .90 .87 .83

.94 .88 .85 .82

.92 .87 .84 .81

50 30 201.11 1.11 1.111.07 1.06 1.051.03 1.01 1.001.00 .98 .96

.97 .95 .92

.95 .92 .90

.93 .90 .87

.91 .88 .86

.89 .86 .84

.88 .85 .82

.86 .83 .81

50 30 201.06 1.06 1.061.03 1.02 1.011.00 .99 .97

.98 .96 .94

.96 .93 .91

.93 .91 .89

.92 .89 .87

.90 .87 .85

.88 .86 .84

.87 .84 .82

.86 .83 .81

50 30 201.02 1.02 1.021.00 .99 .99

.98 .97 .95

.96 .94 .93

.94 .92 .90

.92 .90 .88

.90 .88 .86

.89 .87 .85

.88 .85 .83

.86 .84 .82

.85 .83 .81

01.00

.97

.94

.91

.89

.87

.85

.84

.82

.81

.80

Coefficients Of Utilization - ZonalCavityMethodZonal Lumen Summary

Zone Lumens % Lamp % Luminaire0-30 3,203.9 86.4% 86.5%0-40 3,438.2 92.7% 92.9%0-60 3,655.2 98.6% 98.7%60-90 47.8 1.3% 1.3%0-90 3,703.0 99.9% 100%90-180 0 0% 0%0-180 3,703.0 99.9% 100%Total Efficiency: 99.9%

Zonal Lumen

Center Beam fc Beam Width

3.0 ft

6.7 ft

10.0 ft

13.3 ft

16.7 ft

20.0 ft

9634 fc

2408 fc

1070 fc

602 fc

385 fc

268 fc

0.6 ft

1.1 ft

1.7 ft

2.3 ft

2.9 ft

3.4 ft

0.6 ft

1.3 ft

1.9 ft

2.5 ft

3.1 ft

3.8 ft

�� Vert. Spread: 9.9º�� Horiz. Spread: 10.8º

Illuminance at DistanceColorBlaze7205

152535455565758590

0 22.5 44 67.5 90107042

522862420

856582292129

5726

30

10704255893

2320798568286116

4518

00

10704258208

2368802558280116

4416

00

10704258635

2373838561273114

4518

00

10704253360

2332792550278116

4820

00

Polar Candela Distribution

RCC %: Ceiling reflectance percentage, RW %: Wall reflectance percentage, RCR: Room cavity ratio

Effective Floor Cavity Reflectance: 20% RCC %: 80 70 50 30 10 0RW %:RCR: 0

123456789

10

70 50 30 01.19 1.19 1.19 1.191.15 1.13 1.11 1.101.12 1.08 1.05 1.031.08 1.04 1.00 .981.05 1.00 .97 .941.03 .97 .94 .911.00 .95 .91 .88

.98 .92 .89 .86

.96 .91 .87 .84

.95 .89 .85 .83

.93 .87 .84 .82

70 50 30 01.16 1.16 1.16 1.001.13 1.11 1.09 .971.09 1.06 1.04 .941.07 1.03 .99 .921.04 .99 .96 .901.01 .97 .93 .88

.99 .94 .91 .86

.97 .92 .88 .85

.95 .90 .87 .83

.94 .88 .85 .82

.92 .87 .84 .81

50 30 201.11 1.11 1.111.07 1.06 1.051.03 1.01 1.001.00 .98 .96

.97 .95 .92

.95 .92 .90

.93 .90 .87

.91 .88 .86

.89 .86 .84

.88 .85 .82

.86 .83 .81

50 30 201.06 1.06 1.061.03 1.02 1.011.00 .99 .97

.98 .96 .94

.96 .93 .91

.93 .91 .89

.92 .89 .87

.90 .87 .85

.88 .86 .84

.87 .84 .82

.86 .83 .81

50 30 201.02 1.02 1.021.00 .99 .99

.98 .97 .95

.96 .94 .93

.94 .92 .90

.92 .90 .88

.90 .88 .86

.89 .87 .85

.88 .85 .83

.86 .84 .82

.85 .83 .81

01.00

.97

.94

.91

.89

.87

.85

.84

.82

.81

.80

Coefficients Of Utilization - ZonalCavityMethodZonal Lumen Summary

Zone Lumens % Lamp % Luminaire0-30 4,805.8 86.4% 86.5%0-40 5,157.3 92.7% 92.9%0-60 5,482.8 98.6% 98.7%60-90 71.7 1.3% 1.3%0-90 5,554.5 99.9% 100%90-180 0 0% 0%0-180 5,554.5 99.9% 100%Total Efficiency: 99.9%

Zonal Lumen

PhotometricsPhotometricdataisbasedontestresultsfromanindependentNISTtraceabletestinglab.IESdataisavailableatwww.philipscolorkinetics.com/support/ies.

Forluxmultiplyfcby10.7

267ft(81.4m)1fcmaximumdistance

327ft(99.7m)1fcmaximumdistance

05

152535455565758590

0 22.5 44 67.5 907136134857

1613571388195

863817

20

7136137262

1547532379191

773012

00

7136138805

1579535372187

772911

00

7136139090

1582559374182

763012

00

7136135573

1555528367185

773213

00

Cd: 0

11,894

23,787

35,681

47,574

59,468

71,361VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

Cd: 0

17,840

35,681

53,251

71,361

89,201

107,042VA: 0º 10º 20º 30º 40º

90º

80º

70º

60º

50º

� - 0º H � - 90º H

LED Lumens EfficacyRGB 3708 13.2

LED Lumens Efficacy

RGB 5562 13.2

These f igures are scaled based on the ColorBlaze 48 photometrics to approximate the light output of ColorBlaze 72.

ColorBlaze Product Guide6

SpecificationsDuetocontinuousimprovementsandinnovations,specificationsmaychangewithoutnotice.

Item Specification ColorBlaze48 ColorBlaze72

Output

BeamAngle 10° 10°

Lumens* 3708 5562

LEDChannels Red/Green/Blue

MixingDistance 6in(152mm)touniformlight

LumenMaintenance† 50,000+hoursL50@50°C(fulloutput)

ElectricalInputVoltage 100–240VAC,auto-switching,50/60Hz

PowerConsumption 280Wmaximumatfulloutput,steadystate

420Wmaximumatfulloutput,steadystate

ControlInterface DMX

ControlSystem Philipsfullrangeofcontrollers,includingLightSystemManager,ColorDialPro,andiPlayer3,orthird-partycontrollers

Physical

Dimensions (Height x Width x Depth)

7.5x45.3x6.5in (191x1150x165mm)

7.5x68.7x6.5in (191x1746x165mm)

Weight 40lb(18.1kg) 60lb(27.2kg)

Housing Extrudedaluminium,blackfinish

Lens Clearpolycarbonate

FixtureConnections IECpowercable,RJ45,Ethercon,orXLR-5dataconnections

TemperatureRanges-40°–122°F (-40°–50°C)Operating -4°–122°F (-20°–50°C)Startup-40°–176°F (-40°–80°C)Storage

Humidity 0–95%,non-condensing

CertificationandSafety

Certification UL/cUL,FCCClassA,CE,CQC,PSE

Environment DryLocation,IP20

7.74 in(197 mm) 45.26 in

(1150 mm)

44.8 in(1138 mm)

68.7 in(1746 mm)

4.79 in(122 mm)

.2 in(5 mm)

1.18 in(30 mm)

1.18 in(30 mm)

1.2 in(31 mm)

2.4 in(60 mm)

3.31 in(84 mm)

7.5 in(191 mm)

6.5 in(165 mm)

5.25 in(133 mm)

68.3 in(1734 mm)

5.25 in(133 mm)

7.74 in(197 mm) 45.26 in

(1150 mm)

44.8 in(1138 mm)

68.7 in(1746 mm)

4.79 in(122 mm)

.2 in(5 mm)

1.18 in(30 mm)

1.18 in(30 mm)

1.2 in(31 mm)

2.4 in(60 mm)

3.31 in(84 mm)

7.5 in(191 mm)

6.5 in(165 mm)

5.25 in(133 mm)

68.3 in(1734 mm)

5.25 in(133 mm)

7.74 in(197 mm) 45.26 in

(1150 mm)

44.8 in(1138 mm)

68.7 in(1746 mm)

4.79 in(122 mm)

.2 in(5 mm)

1.18 in(30 mm)

1.18 in(30 mm)

1.2 in(31 mm)

2.4 in(60 mm)

3.31 in(84 mm)

7.5 in(191 mm)

6.5 in(165 mm)

5.25 in(133 mm)

68.3 in(1734 mm)

5.25 in(133 mm)

7.74 in(197 mm) 45.26 in

(1150 mm)

44.8 in(1138 mm)

68.7 in(1746 mm)

4.79 in(122 mm)

.2 in(5 mm)

1.18 in(30 mm)

1.18 in(30 mm)

1.2 in(31 mm)

2.4 in(60 mm)

3.31 in(84 mm)

7.5 in(191 mm)

6.5 in(165 mm)

5.25 in(133 mm)

68.3 in(1734 mm)

5.25 in(133 mm)

*LumenmeasurementcomplieswithIESLM-79-08.† L50=50%lumenmaintenance(whenlightoutputdropsbelow50%ofinitialoutput).Ambientluminairetemperaturesspecified.LumenmaintenancecalculationsarebasedonlifetimepredictiongraphssuppliedbyLEDsourcemanufacturers.Calculationsforwhite-lightLEDfixturesarebasedonmeasurementsthatcomplywithIESLM-80-08testingprocedures.Refertowww.philipscolorkinetics.com/support/appnotes/lm-80-08.pdfformoreinformation.

ColorBlaze Product Guide 7

AccessoriesDesignedspecificallyforColorBlaze,AccessoryHoldersscrewtopre-tappedholesonthesidesoftheColorBlazehousing.AccessoryHoldersholdGlassSpreadLensesandadditionalaccessoriesavailablebyspecialorderfromCityTheatricalInc.ProSeriesAccessoryHoldersfeatureaspringcliptoprotectaccessoriesfromvibrationsandroughhandling.BlackorwhiteAccessoryHolderscanbeusedtomatchfinisheswhenColorBlazefixturesarerecessedinceilingsorwalls.

Fixtures and Replacement PartsColorBlazefixturesarepartofacompletesystemwhichincludesanyPhilipscontroller,including ColorDialPro,LightSystemManager,andiPlayer3,orathird-partycontroller;andRJ45,Ethercon,orXLR-5datacablesforconnectingfixturestogetherinseries,ortocontrollers.

Item Type ItemNumber Philips12NC

ColorBlazefixtures ColorBlaze72 116-000021-00 910503700614

48 116-000022-00 910503700613

ColorBlazereplacementparts

PowerSupplyWithoutThermalSensor 120-000041-00 910503700131

WithThermalSensor 120-000042-00 910503700132

Fan 120-000043-00 910503700133

AirInletFilter 120-000044-00 910503700134

ControllerPanel72 120-000045-01 910503700136

48 120-000045-00 910503700135

LEDBoard

Cree7090 120-000046-01 910503700137

Cree7090XR-E 120-000073-00 910503700615

Luxeon 120-000046-00 —

IECConnector 120-000053-00 910503700144

ClearLens72 120-000048-00 910503700139

48 120-000047-00 910503700138

MountingBracketBracketsandHandles 120-000049-01 910503700140

HandlesOnly 120-000050-00 910503700141

T-HandleStyleMountingBracketBracketsandHandles 120-000051-00 910503700142

HandlesOnly 120-000052-00 910503700143

IncludedintheboxColorBlazefixture(2)mountingbracketsandknobsUL-rated6ft(1.8m)IECpowercableCE-rated6ft(1.8m)IECpowercableInstallationInstructions

UseItemNumberwhenorderinginNorthAmerica.

Item Type ItemNumber Philips12NC

AccessoryHolders

ColorBlaze72

StandardWhite 120-000001-00 —

Black 120-000001-01 —

ProSeriesWhite 120-000001-02 —

Black 120-000001-03 —

ColorBlaze48

StandardWhite 120-000002-00 —

Black 120-000002-01 —

ProSeriesWhite 120-000002-02 —

Black 120-000002-03 —

GlassSpreadLenses

ColorBlaze72 (4) 17 in (432 mm) sections

36°/50°horiz.spread 120-000023-00 —

40°/40°horiz./vert.spread 120-000023-01 —

ColorBlaze48 (3) 14 in (356 mm) sections

36°/50°horiz.spread 120-000024-00 —

40°/40°horiz./vert.spread 120-000024-01 —

InadditiontoAccessoryHoldersandGlassSpreadLenses,CityTheatricalInc.offersalineofaccessoriesforColorBlaze,suchastophatsandeggcratelouvers,availablebyspecialorder.Refertowww.citytheatrical.comfordetails.

UseItemNumberwhenorderinginNorthAmerica.

ColorBlaze Product Guide8

InstallationColorBlazefixtureshaveintegratedpowersuppliesandpushbuttonaddressingcontrolslocatedonthebackofthefixturehousing.Fortheatricalinstallationswherefixturesarereadilyaccessible,youtypicallymountColorBlazefixturesfirst,thenaddressandconfigurethemasnecessary.Forpermanentinstallationswithdynamiceffects,youmayfinditconvenienttoconfigureandaddressyourfixturesfirst,inastagingareawherethefixturesareeasilyaccessible.Forexample,werecommendconfiguringandaddressingColorBlazefixturesbeforeinstallingtheminarchitecturalapplicationswherethefixtureswillbemountedpermanentlyagainstflatsurfaces,inniches,orinotherareasthatmaybedifficulttoaccess.

Owner / User Responsibilities Itistheresponsibilityofthecontractor,installer,purchaser,owner,andusertoinstall,maintain,andoperateColorBlazefixturesinsuchamannerastocomplywithallapplicablecodes,stateandlocallaws,ordinances,andregulations.Consultwiththeappropriateelectricalinspectortoensurecompliance.

Create a Lighting Design Plan Regardlessofthedetailsofyourinstallation,it’sgoodpracticetocreatealightingdesignplanthatidentifiesyourfixtures,recordstheDMXaddressesassignedtothem,andidentifiestheirlocationsinrelationtootherrequiredhardware.Forcomplexinstallationsdisplayinglightshowswithdynamiceffects,suchalightingdesignplanisessential.

Tocreatealightingdesignplan,determinetheappropriatelocationofeachColorBlazefixtureinrelationtopowersourcesandcontrollers.Onanarchitecturaldiagramorotherdiagramthatshowsthephysicallayoutoftheinstallation,identifythelocationsofallcontrollers,fixtures,powersources,andcables.Tostreamlineinstallationandaidinlightshowprogramming,youcanaffixalabelidentifyingtheorderorplacementintheinstallationtoaninconspicuouslocationoneachColorBlazefixture’shousing.

Keepthefollowingconsiderationsinmindwhenplanningyourinstallation:

• Theintegrated,auto-switchingpowersupplyautomaticallyadjuststoany 50/60Hzpowersourcefrom110–240V.EachColorBlazefixtureincludesa6ft(1.8m)detachablecablewithastandardIECconnectorandflyingleads.Youmustconnectthecable’sflyingleadstoa3-wireplugappropriateforyourgeographiclocation.

• YoucanconnectColorBlazefixturesinseriesusinganycombinationofRJ45,Ethercon,andXLR-5datacables.

• ColorBlazefixturescanworkasasingleunit,oryoucansetfixturestohavemultiplesegmentsthatdisplaydifferentcolorssimultaneouslyfordynamiceffects.Segmentlengthsdifferdependingonfixturelengthandconfiguration.Wheninstallingfixturesend-to-end,youcancreatevirtualsegmentsthatspanmultiplefixtures.

• YoucanmixColorBlaze48andColorBlaze72fixturesinasinglerun.Amixtureoffixturelengthscanofferflexibilityinarchitecturalapplicationswhereyouneedtoinstallfixturesaroundcornersorinconfinedareas.

• YoucanmountColorBlazefixturesend-to-end,oryoucanspacethemhoweveryouwish,solongasthemaximumdistancefromacontrollertothelastfixtureinaseriesdoesnotexceed1000ft(300m)withoutaDMXrepeater.

• Eachseriesoffixturescanuseupto512uniqueDMXaddresses.Sinceeachfixturesegmentrequiresthreeaddresses,youcanhaveupto170uniquelyaddressedsegmentswithinasingleseries.Forexample,youcouldcreateaseries

E Refer to the ColorBlaze Installation Instructions for specif ic warning and caution statements.

NUMBER OF GROUPSDMX START CHANNEL TEST

DMX IN24 VDC OUT

CLASS 2 CIRCUITS

DMX OUT

Numberofgroups

DMXstartchannel

Test

DMXinputsandoutputs

Connecting ColorBlaze to an Ethernet ControllerEthernetcontrollersfromPhilips,suchasLightSystemManagerorVideoSystemManagerPro,useKiNET,thestandardEthernetlightingprotocolfromPhilipsColorKinetics.TocontrolColorBlazefixtureswithaPhilipsColorKineticsEthernetcontroller,usetheMulti-ProtocolConverterwithaPower-over-Ethernet(PoE)injectororPoEswitch.

Multi-Protocol Converter

ColorBlaze Product Guide 9

of14ColorBlaze72fixtures,eachwith12segments(14fixturesx12segmentsx3=504addresses),oraseriesof85ColorBlaze48fixtures,eachwith2segments(85fixturesx2segmentsx3=510addresses).

Connect the Power Cable PlugColorBlazehasintegrated,auto-switchingpowersuppliesthatautomaticallyadjusttoany50/60Hzpowersourcefrom110–240V.ColorBlazefixturesareconnecteddirectlytolinepowerusingtheincluded6ft(1.8m)detachablepowercable.Youmustconnectthecable’sflyingleadstoanappropriate3-wireplug.

1. Unpackthefixture,andplaceitinastagingareaorotherlocationwherethecontrolsonthebackofthefixturehousingareeasilyaccessible.

2. Installa2-pole,3-wire,grounded,15Aplugtotheincludedpowercable.Followingtheplugmanufacturer’sinstructions,ground(earth),toline,andneutral.

3. ConnectthepowercabletotheIECinletonthebackoftheColorBlazehousing.

4. TightenthescrewontheIECinlettoholdthepowercableinplace.

Set Fixture SegmentsMakesurethepowerisONbeforeaddressingandconfiguringfixturesbyplugginginthefixture’spowercable.

Toallowafinelevelofcontrolforlightshowswithdynamiceffects,ColorBlazefixturescanbeconfiguredtohavemultipleindividuallyaddressablegroupsoffixturesegments:1,2,4,or8forColorBlaze48,or1,2,3,4,6,or12forColorBlaze72.Yousetthefixture’sstartDMXchannel(address),andtheonboardcontrolsautomaticallyassignuniqueDMXaddressestoeachsegment.

EachColorBlazefixtureisfactory-addressedtohave4groupsandastartingDMXchannelof1.Forlightshowdesignsdisplayingstaticeffects,nochangestothefactory-defaultsettingsarenecessary.However,iffixtureswerepreviouslyconfiguredforuseinotherinstallations,youmayhavetoresetthem.Forlightshowdesignswithdynamiceffects,youmayneedtosetthenumberofgroupseachfixturewillhave.

TosetthenumberofgroupsforaColorBlazefixture:

1. IntheNUMBEROFGROUPSsectiononthebackofthefixturehousing,pressthe+and-buttonstoscrollthroughtheoptions:1,2,4,orA(8)forColorBlaze48,or1,2,3,4,6,orA(12)forColorBlaze72.

2. Forcomplexinstallationswhereyousetdifferentnumbersofgroupsondifferentfixtures,it’sgoodpracticetonotateeachfixture’sgroupsettingonthelightingdesignplan.

E If you use a cable other than the included IEC power cable, make sure that the cable is equivalent in size and rating, and that it meets local standards. Ensure that the plug on the power cable can be held securely in place by the IEC inlet locking mechanism, which is designed for a C13 plug.

E You can test a ColorBlaze f ixture by pressing and holding the TEST button. If the f ixture is working properly, each group of LEDs (8 for ColorBlaze 48, 12 for ColorBlaze 72) will briefly illuminate in sequence.

NUMBER OF GROUPS

DMX START CHANNEL

CHANNEL TEST

OF GROUPS

TEST

OOOOOOFFFF F GGGGGGGRRRRRROOOOOOUOUUUUUUPPPPPSPSSS

TTTTSTSTSSSESEEETETETTTTL

CCCCCCCCHHHHHHAHAAAAAAANANNNNNNNNNNNNEL

NUMBER OF GROUPS

DMX START CHANNEL

CHANNEL TEST

OF GROUPS

TEST

OOOOOOFFFF F GGGGGGGRRRRRROOOOOOUOUUUUUUPPPPPSPSSS

TTTTSTSTSSSESEEETETETTTTL

CCCCCCCCHHHHHHAHAAAAAAANANNNNNNNNNNNNEL

IncludedintheboxColorBlazefixture(2)mountingbracketsandknobsUL-rated6ft(1.8m)IECpowercableCE-rated6ft(1.8m)IECpowercableInstallationInstructions

6ft(1.8m)

6ft(1.8m)

UL / cUL

CE

ColorBlaze Product Guide10

Keepthefollowingconsiderationsinmindwhensettingthenumberoffixture groups:

• Thenumberofgroupseffectivelydeterminessegmentlength.Forexample,settingaColorBlaze48to4groupsresultsin4segmentsofroughly1footeach.SettingaColorBlaze72to3groupsresultsin3segmentsofroughly2feeteach.ThefollowingtablegivesthesegmentlengthsforthedifferentsettingsavailableonColorBlaze48andColorBlaze72.

• Asthetableshows,youcanmixColorBlaze48andColorBlaze72fixturesinthesameserieswhilemaintainingconsistentsegmentlengthsof2feet,1foot,or.5feet.

• Ifyouinstallfixturesofthesamelengthendtoend,youcancreatevirtualsegmentsthatspanmultiplefixtures.Forexample,youcancreatevirtual9ftsegmentswithColorBlaze72fixturesbyalternating1-segmentand2-segmentfixtures.

Set the DMX Start ChannelColorBlazefixturescommunicatedirectlywithPhilipsorthird-partycontrollersbymeansofDMXaddresses,orchannels.EachColorBlazefixtureisfactory-addressedtoastartingDMXchannelof1.Forlightshowdesignsdisplayingstaticeffects,nochangestothefactory-defaultsettingsarenecessary.However,iffixtureswerepreviouslyreaddressedforuseinotherinstallations,youmayhavetoresetthemtothesamestartingDMXchannel.Forlightshowdesignsdisplayingdynamiceffects,youmustsetdifferentstartingchannelforeachfixtureinaseriestoensurethatallfixturesegmentsareuniquelyaddressed.

Number of Groups Settings

SegmentLength ColorBlaze72 ColorBlaze48

6ft 1 —

4ft — 1

3ft 2 —

2ft 3 2

1.5ft 4 —

1ft 6 4

.5ft A(12) A(8)

2 ft (610 mm)segments

9 ft (2.74 m) segments

ColorBlaze 48

ColorBlaze 48 ColorBlaze 48 ColorBlaze 48

1 13 25

ColorBlaze 72

ColorBlaze 72 ColorBlaze 72

DMX addressing

ColorBlaze 72 ColorBlaze 72 ColorBlaze 72

ColorBlaze 48

2 ft (610 mm)segments

9 ft (2.74 m) segments

ColorBlaze 48

ColorBlaze 48 ColorBlaze 48 ColorBlaze 48

1 13 25

ColorBlaze 72

ColorBlaze 72 ColorBlaze 72

DMX addressing

ColorBlaze 72 ColorBlaze 72 ColorBlaze 72

ColorBlaze 48

ColorBlaze Product Guide 11

Tosetafixture’sDMXstartchannel:

1. IntheDMXSTARTCHANNELsectiononthebackofthefixturehousing,pressthe+and-buttonstoscrollthroughallavailableDMXaddresses(1–512).

2. Ifyou’reenablingdynamiceffectsbysettingdifferentDMXstartingchannelsforeachfixtureinaseries,youcanstreamlineconfigurationandlightshowprogrammingbynotatingtheDMXstartingchannelofeachfixturesegmentonthelightingdesignplan.

Keepthefollowingconsiderationsinmindwhenaddressingyourfixtures:

• ColorBlazeonboardaddressingautomaticallyassignsconsecutiveDMXaddressestothefixture’ssegments,startingwiththechannelyouset.EachsegmentreceivesthreeDMXaddresses,oneforred,oneforblue,andoneforgreen.ThefollowingexampleshowsthestartingDMXaddressesforallfixturesegmentswhenthestartingDMXaddressissetto1.

• Withthebackofthefixturehousingtowardyou,segmentsextendinsequencefromtheleftofthefixturetotheright.

• MakesurethattheDMXstartchannelallowsenoughDMXaddressesforallofthefixture’ssegments,orthefixturewillnotfunctionproperly.Forexample,afixturewith4groupsrequires12DMXaddresses,3persegment.Therefore,theDMXstartchannelshouldbe501orlower.

• Forlightshowswithdynamiceffects,setstartchannelssothateachfixtureinaseriesreceivesauniquesetofDMXaddresses.Forexample,inaseriesof3fixtures,eachwith4groups,youcanensurethateachfixtureisuniquelyaddressedbysettingthestartchannelofthefirstfixtureto1,thestartchannelofthesecondfixtureto13(1+12),andthestartchannelofthethirdfixtureto25(13+12).

DMXStartChannelPerSegment

1group Segment1 001

2groups Segment1 001

Segment2 004

4groups Segment1 001

Segment2 004

Segment3 007

Segment4 010

A(8)groups Segment1 001

Segment2 004

Segment3 007

Segment4 010

Segment5 013

Segment6 016

Segment7 019

Segment8 022

DMXStartChannelPerSegment

1group Segment1 001

2groups Segment1 001

Segment2 004

3groups Segment1 001

Segment2 004

Segment3 007

4groups Segment1 001

Segment2 004

Segment3 007

Segment4 010

6groups Segment1 001

Segment2 004

Segment3 007

Segment4 010

Segment5 013

Segment6 016

A(12)groups Seg1 001

Seg2 004

Seg3 007

Seg4 010

Seg5 013

Seg6 016

Seg7 019

Seg8 022

Seg9 025

Seg10 028

Seg11 031

Seg12 034

ColorBlaze48/DMXStartChannel=1

ColorBlaze72/DMXStartChannel=1

NUMBER OF GROUPS

DMX START CHANNEL

CHANNEL TEST

OF GROUPS

TEST

OOOOOOFFFF F GGGGGGGRRRRRROOOOOOUOUUUUUUPPPPPSPSSS

TTTTSTSTSSSESEEETETETTTTL

CCCCCCCCHHHHHHAHAAAAAAANANNNNNNNNNNNNEL

2 ft (610 mm)segments

9 ft (2.74 m) segments

ColorBlaze 48

ColorBlaze 48 ColorBlaze 48 ColorBlaze 48

1 13 25

ColorBlaze 72

ColorBlaze 72 ColorBlaze 72

DMX addressing

ColorBlaze 72 ColorBlaze 72 ColorBlaze 72

ColorBlaze 48

ColorBlaze Product Guide12

Mount the Fixtures ColorBlazefixturescomewithattachedmountingbracketsdesignedfor.5inmountinghardware.FixturescanbemountedtoasurfaceortoapipeortrusswithstandardpipeclampsorCheeseboroughclamps.Ifyourinstallationcallsforspecialmounting,youcanreplacetheincludedmountingbracketswithseparatelyavailableT-handlemountingbrackets.

1. Verifythatallsupportingequipment(controllers,connectionstopowersources)isinplace.ColorBlazefixturesareintendedtoplugintolinepowerusingtheincluded6ft(1.8m)detachableIECpowercable.

2. Mountfixturesasdictatedbylocal,state,ornationalcodes.Consultastructuralengineerorsafetyprofessionaltoensurepropermounting.

3. EachColorBlazefixtureisdesignedforusewithoneormoresafetycablestotetherthefixturetoasecureanchorpoint.WhensuspendingorinstallingColorBlazefixturesoverhead,orwhendictatedbylocalorstatecodeoradvisedbyastructuralengineer,loopsafetycablesthroughoneorbothoftherestrainingholeslocatedattheeitherendoftheColorBlazehousing.Securelyanchorthesafetycablesusingamethodthatfollowscodeorengineer’srequirements.

Connect Data and Power1. SupplypowertoeachColorBlazefixturebypluggingthemin.

2. UsingastandardRJ45,Ethercon,orXLR-5datacable,connectdatadirectlyfromaDMXcontroller’sdataoutputporttoaDMXINportonthefirstColorBlazefixtureinaseries.

SafetycableminimumrequirementsMaterial Determinedbyinstaller/owner

BreakLoadMinimumbreakloadforcableandallcableanchoringconstructionis600lb(272kg)total.

Construction 7x7(49wires)preformedstranded

E To connect data from a Philips Color Kinetics Ethernet controller, such as Light System Manager or Video System Manager Pro, you must a converter, such as the Multi-Protocol Converter.

E Make sure to install f ixtures with the same orientation. This is especially important in installations with light shows that display dynamic effects.

NUMBER OF GROUPSDMX START CHANNEL TEST

DMX IN24 VDC OUT

CLASS 2 CIRCUITS

DMX OUT

ColorBlaze Product Guide 13

3. CreateaseriesbyconnectingaDMXOUTportonthefirstfixturetoa DMXINportonthenextfixtureinsequence,usingastandardRJ45,Ethercon,orXLR-5datacable.

4. Repeatstep3foreachColorBlazefixtureintheseries.

5. InsertastandarddataterminatorinaDMXOUTportonthelastfixtureintheseries.

Aim and Lock the FixturesMakesurepowerisONbeforeaimingfixtures.

1. LoosenthelockingknobsateachendofaColorBlazefixturetoallowthefixturetorotatefreelythrough180°.

2. Rotatethefixturetothedesiredposition.

3. Hand-tightenthelockingknobs.

4. (Optional)YoucanuseanM10hexkeywrenchtolockthefixturesecurelyinposition.

Cleaning the ColorBlaze Housing and Air Intake FilterColorBlazehasatemperaturemonitoringfeaturethatprotectsthefixturefromextremetemperatures.Iftheoperatingtemperaturerisestoanunsafelevel,thelightsdimtoadullred.After30minutes,thelightsautomaticallyreturntofullintensityandresumenormaloperation.

Foradditionalheatprotection,ColorBlazefeaturesanonboardfan.Atelevatedambienttemperatures,thefanengagesathalfspeed.Iftheambienttemperaturecontinuestorise,thefanrunsatfullspeed.

Tohelppreventoverheating,werecommendthatyouinspectandcleantheColorBlazehousingandairintakefilterregularly.

51

32 4

51

342

PUSH PUSH PUSH PUSH

E Connections between ColorBlaze f ixtures are not connector-specif ic. You can use any combination of XLR-5, Ethercon, and RJ45 inputs and outputs.

E Do not look directly into the fixture when aiming and locking.

ColorBlaze Product Guide14

1. Disconnectpowertothefixture.NeverattempttocleanorserviceColorBlazewiththepowerconnected.

2. Rotatethefixturetoaccessthesidesofthefixturehousing.Inspecttheheatfins,andmakesuretheyarefreeofdebrisandheavydust.

3. Rotatethefixturetoaccessthebackofthehousing,andlocatetheairfilterintakesoneitherend.

4. Removethefourscrewsthatholdthefilterinplace.Removethefilter,takingcaretopreventthescrewsorwashersfromfallingintotheairintake.

5. Cleanthefilterwithwater,anddryitthoroughly.

6. Replacethefilter,ensuringthatthegasketandwashersarepositionedproperly.

ColorBlaze Product Guide 15

Cleaning ColorBlaze LensesYoucanremoveandcleanColorBlazelenseswithoutremovingthemountinghandlesoropeningthefixture’shousing.

1. Removetheretainingscrewsalongtopedgeofhousing.ColorBlaze48hasfivescrews,andColorBlaze72hassix.

2. Tiplensout

3. Cleanthelenswithwaterandmilddetergentusingasoftcleaningcloth.Wipethelensdry. Cleanthelenswithwaterandmilddetergentusingasoftcleaningcloth,andwipedry.Becausetheywillscratch,soften,pit,haze,yellow,mar,orcrackthelens,donotusepapertowels,abrasivecleaningproducts,windowcleaners,orcleaningsolutionscontainingchemicalssuchasammonia,sodiumhydroxide,andisopropylalcohol.

4. Replacethelens,andsecureitbyreplacingtheremovedscrews.

Installing ColorBlaze Replacement PartsAfullrangeofreplacementpartsisavailabletokeepColorBlazefixturesinserviceforthelonghaul.Replacementpartsincludepowersupplies,fans,airinletfilters,controllerpanels,LEDboards,IECconnectors,lenses,andmountingbrackets.Fordetailedinstallationinstructions,downloadtheColorBlazeReplacementPartsReferenceGuidefromwww.philipscolorkinetics.com/ls/rgb/colorblaze/.

Philips Color Kinetics3 Burlington Woods DriveBurlington, Massachusetts 01803 USATel 888.385.5742Tel 617.423.9999Fax 617.423.9998www.philipscolorkinetics.com

Copyright © 2009 – 2015 Philips Solid-State Lighting Solutions, Inc. All rights reserved. Chromacore, Chromasic, CK, the CK logo, Color Kinetics, the Color Kinetics logo, ColorBlast, ColorBlaze, ColorBurst, eW Fuse, ColorGraze, ColorPlay, ColorReach, iW Reach, eW Reach, DIMand, EssentialWhite, eW, iColor, iColor Cove, IntelliWhite, iW, iPlayer, Optibin, and Powercore are either registered trademarks or trademarks of Philips Solid-State Lighting Solutions, Inc. in the United States and / or other countries. All other brand or product names are trademarks or registered trademarks of their respective owners. Due to continuous improvements and innovations, specifications may change without notice.Cover Photo: Courtesy of Mark Thomas Productions, Ltd. DAS-000014-00 R05 06-15