2
Para F`C 210 Kg/cm2 7.89 bls. 42.5 335.33 kg/m3 300 Kg/cm3 x kg/cm2 335.33 Kg/cm3 210 kg/cm2 x = 300 Kg/cm3 x 210 kg/cm2 = 187.87 kg/cm2 335.33 Kg/cm3 PARA PROBETAS 1 m3 187.87 kg 0.031808 m3 X PERDIDA x = 0.031808 m3 x 187.87 kg = 5.98 kg 1.07 6.39 kg 1 m3 1 m3 146.00 kg 0.031808 m3 X PERDIDA x = 0.031808 m3 x 146.00 kg = 4.64 kg 1.07 4.97 kg 1 m3 1 m3 1868.00 kg 0.031808 m3 X PERDIDA x = 0.031808 m3 x 1868.00 kg = 59.42 kg 1.07 63.58 kg 1 m3 Para F`C 175 Kg/cm2 6.42 bls. 42.5 272.85 kg/m3 250 Kg/cm3 x kg/cm2 272.85 Kg/cm3 175 kg/cm2 x = 250 Kg/cm3 x 175 kg/cm2 = 160.34 kg/cm2 272.85 Kg/cm3 PARA PROBETAS 1 m3 160.34 kg 0.031808 m3 X PERDIDA x = 0.031808 m3 x 160.34 kg = 5.10 kg 1.07 5.46 kg 1 m3 1 m3 190.00 kg 0.031808 m3 X PERDIDA x = 0.031808 m3 x 190.00 kg = 6.04 kg 1.07 6.47 kg 1 m3 1 m3 1937.00 kg 0.031808 m3 X PERDIDA x = 0.031808 m3 x 1937.00 kg = 61.61 kg 1.07 65.92 kg 1 m3 CEMENTO TOTAL A PESAR AGUA TOTAL A PESAR AGREGADOS TOTAL A PESAR CEMENTO AGUA AGREGADOS TOTAL A PESAR TOTAL A PESAR TOTAL A PESAR Para preparar muestras de 300kg/m3 con HORMIGON Para preparar muestras de 250kg/m3 con HORMIGON

CONCRETOS CON 300,250,200Kg-m3.pdf

Embed Size (px)

Citation preview

  • Para F`C 210 Kg/cm2 7.89 bls. 42.5 335.33 kg/m3

    300 Kg/cm3 x kg/cm2335.33 Kg/cm3 210 kg/cm2

    x = 300 Kg/cm3 x 210 kg/cm2 = 187.87 kg/cm2335.33 Kg/cm3

    PARA PROBETAS

    1 m3 187.87 kg0.031808 m3 X

    PERDIDAx = 0.031808 m3 x 187.87 kg = 5.98 kg 1.07 6.39 kg

    1 m3

    1 m3 146.00 kg0.031808 m3 X

    PERDIDAx = 0.031808 m3 x 146.00 kg = 4.64 kg 1.07 4.97 kg

    1 m3

    1 m3 1868.00 kg0.031808 m3 X

    PERDIDAx = 0.031808 m3 x 1868.00 kg = 59.42 kg 1.07 63.58 kg

    1 m3

    Para F`C 175 Kg/cm2 6.42 bls. 42.5 272.85 kg/m3

    250 Kg/cm3 x kg/cm2272.85 Kg/cm3 175 kg/cm2

    x = 250 Kg/cm3 x 175 kg/cm2 = 160.34 kg/cm2272.85 Kg/cm3

    PARA PROBETAS

    1 m3 160.34 kg0.031808 m3 X

    PERDIDAx = 0.031808 m3 x 160.34 kg = 5.10 kg 1.07 5.46 kg

    1 m3

    1 m3 190.00 kg0.031808 m3 X

    PERDIDAx = 0.031808 m3 x 190.00 kg = 6.04 kg 1.07 6.47 kg

    1 m3

    1 m3 1937.00 kg0.031808 m3 X

    PERDIDAx = 0.031808 m3 x 1937.00 kg = 61.61 kg 1.07 65.92 kg

    1 m3

    CEMENTO TOTAL A PESAR

    AGUA TOTAL A PESAR

    AGREGADOS TOTAL A PESAR

    CEMENTO

    AGUA

    AGREGADOS

    TOTAL A PESAR

    TOTAL A PESAR

    TOTAL A PESAR

    Para preparar muestras de 300kg/m3 con HORMIGON

    Para preparar muestras de 250kg/m3 con HORMIGON

  • Para F`C 90 Kg/cm2 4.85 bls. 42.5 206.13 kg/m3

    200 Kg/cm3 x kg/cm2206.13 Kg/cm3 90 kg/cm2

    x = 200 Kg/cm3 x 90 kg/cm2 = 87.33 kg/cm2206.13 Kg/cm3

    PARA PROBETAS

    1 m3 87.33 kg0.031808 m3 X

    PERDIDAx = 0.031808 m3 x 87.33 kg = 2.78 kg 1.07 2.97 kg

    1 m3

    1 m3 122.00 kg0.031808 m3 X

    PERDIDAx = 0.031808 m3 x 122.00 kg = 3.88 kg 1.07 4.15 kg

    1 m3

    1 m3 2057.00 kg0.031808 m3 X

    PERDIDAx = 0.031808 m3 x 2057.00 kg = 65.43 kg 1.07 70.01 kg

    1 m3

    Para preparar muestras de 200kg/m3 con HORMIGON

    AGUA

    AGREGADOS

    CEMENTO TOTAL A PESAR

    TOTAL A PESAR

    TOTAL A PESAR