Upload
peregrine-andrews
View
234
Download
8
Embed Size (px)
Citation preview
DEKDEK 中級培訓中級培訓
1 . Rail to Table Height
2 . Setting camera reference position
3 . Setting Print Height
4 . Calibrate Vision
5 . CALIBRATION OFFSET
6 .軟體的安裝
Rail to Table HeightRail to Table Height • 1:In Diagnostics select Rising Table module.• 2:Select Home Rising Table and Exit Rising Table module.• 3:Select Rail System Module.• 4:Select Home Rail Width.`• 5:Select Adjust Rail Width•
• 6. Set the board width. 治具的寬度 .• 7. Select drive rail to board width • 8. Select 鬆開夾邊• 9. 將治具板放在軌道的兩邊 .• 10. Select 夾緊夾邊• 11.Select rising table module.• 12.Select table to vision height.
調試調試 RISING TABLERISING TABLE 高度高度
Setting camera reference positionSetting camera reference position
• In camera Axes Diagnostics, select Home Camera X Axis and Run Diagnost.
• Select Home Camera Y Axis and Run Diagnost.
• Select Drive to Reference Position and select Run Diagnost. A box and the white dot on the board clamp is visible on the monitor.
• Using Move Camera X Axis Using Jog Buttons and Move Camera Y Axis Using Jog Buttons, position the box centrally inside the white dot, as shown.
Jog ButtonsJog Buttons
Select Set Reference Position and select Run Diagnost.
Setting Print HeightSetting Print Height 1:Select Diagnostics• 2:Select Screen Change.• 3:Select 鎖定 Screen• 4:Selct Camera Axes• 5:Select Home Camera X Axis• 6:Select Home camera Y Axis • 7:Select Rising Table• 8:Select Home Rising Table• 9:Select Set Reference Print Height, the rising
table
10: Using the Incr. And Decr. buttons adjust the displayed dimension.
• 11:Press the Move button, check rising table• 是否到位 .• 12:select Set Height. 將這個高度設置為印刷高度 .• 13:Select save the new print height, select Exit.
Selecting Exit only, returns to the previous menu without the changes being saved.
Calibrate VisionCalibrate Vision
5:Press Change Screen
CALIBRATION OFFSETCALIBRATION OFFSET
軟體的安裝軟體的安裝
1. 將安裝光盤放到機器的光驅里2. 將機器設置為從光驅起動 , 然后重啟 .
3.Run DEK Set-up program
Option 1 to replace Windows NT partition
Option 2 to reload the entire disk.
Option 3 Backup Product and Calibration Data
4. 選擇 Option 2 機器開始自動安裝軟体 .
5.Select Next
6. 自動 RUN GHOST 安裝軟体 .
7. 安裝完成后 , 自動重啟 .
8. 機器重啟后會讓我們插入一張 A 盤
9 . 可不插入軟碟, Select CANCEL10.DEKSYSTEM 啟動完成后開始初始化 .• 初始化完成後,若無 CLEAN SCREEN 這項功能,
請按如下步驟添加:• 1.Press Maint.(F8)• 2.Press Set Prefs(F5)• 3.Press F10• 4. 輸入 Clean on• 5.Press Exit (F8)• 6.Press Exit (F8)• 然後關機重新啓動即可。
對軟體升級對軟體升級
1. 進入 DIAGNOSTICS//SYSTEM//Terminate Control Program.
2. 放光碟於光驅,讓其自行安裝3. 輸入機器序列號即可4. 重新啓動機器。