donaldson visokotlačni filteri

Embed Size (px)

Citation preview

  • 8/13/2019 donaldson visokotlani filteri

    1/86Hydraulic Filtration 1

    High Pressure Filters

    www.buydonaldson.com

    High Pressure Filters

    High pressure filters are

    positioned between pumps

    and critical components

    such as cylinders, motors

    and valves. They help protect

    these critical components

    from catastrophic failure.

    Donaldson heavy-duty high

    pressure filters are rated

    for working pressures up to

    6500 psi (44818 kPa). Various

    porting sizes and types,

    including manifold style, are

    available for a wide range

    of applications.

    Section Index

    Max Operating Pressure < 6500 psi (450 bar)

    Models arranged from low to maximum flow rates

    In-line Cartridge Filters

    W331 .......................................................128

    HPK02......................................................132

    W341 .......................................................138

    W440 .......................................................142

    FPK02 ......................................................146

    W613 .......................................................152

    W322 .......................................................156

    W350 .......................................................160

    HPK03......................................................164

    W610 .......................................................170

    FPK04 ...................................................... 174

    HPK04......................................................180

    W621 .......................................................188

    W451 .......................................................193

    W620 .......................................................197

    WS620 .................................................... 202

    HPK05..................................................... 207

  • 8/13/2019 donaldson visokotlani filteri

    2/86128 Hydraulic Filtration www.buydonaldson.com

    W331Max Flow: 6 gpm (23 lpm)

    W331 In-Line Cartridge Filters

    Working Pressures to: 3000 psi21,000 kPa210 bar

    Rated Static Burst to: 7500 psi51,700 kPa517 bar

    Fatigue Pressure Rating: 1500 psi10,000 kPa100 bar

    Flow Range to: 6 gpm23 lpm

    The W331 in line filter assembly offers all aluminum construction with a positive sealing poppet type bypass for

    reliability and zero leakage. Donaldson DT high-performance 4-layer media is offered in five different media grades.

    The differential pressure indicator line is designed to work with the wide assortment of bypass valves. Thermal

    lockout and surge control are two key features incorporated in many of the differential pressure indicators.

    Aluminum head and housing

    Compact design for use with servo or proportional valve

    Positive sealing poppet for zero leakage

    Beta Rating Performance to 5(c)=1000

    Porting Size Options SAE-8 O-ring

    Assembly Weight 4.25 lbs / 1.9 kg

    Replacement Filter Lengths 3.44" / 87.3mm

    Standard Bypass Ratings 50 psi / 345 kPa / 3.5 bar No Bypass

    Operating Temperatures -45 to 250F (-43 to 121C)

    Filter Collapse Ratings 150 psi / 1034 kPa / 10.3 bar (standard) 3000 psi / 20,700 kPa / 206.8 bar (high collapse)

    Features

  • 8/13/2019 donaldson visokotlani filteri

    3/86Hydraulic Filtration 1www.buydonaldson.com

    W331Max Flow: 6 gpm (23 lpm)

    Differential Indicators: Indicators are designed to actuate at approximately 80% of bypass valve cracking pressure. It is recommendedthat an indicator with a bypass setting of 100 psid is used with a non-bypass housing.

    Surge Control: This optional feature is used to dampen pressure surges or spikes to avoid premature actuation of the indicator. Surgecontrol delays the indicator response.

    Thermal Lockout: The Thermal Lockout prevents premature signaling of a bypass condition created by viscous fluid during cold start-ups.Normal indicator actuation capability is resumed once the operating temperature of the fluid reaches approximately 80F / 27C.

    Note: The female plug (connector) is to

    be furnished by customer.

    I

    92.08

    (3.63)

    76.20

    (3.00)

    38.10

    (1.50)

    IN OUT

    P Indicator

    Access Plug for Bypass Valve

    (SAE-6 Socket Plug)

    175.51

    (6.91)Max

    124.71

    (4.91)

    Max

    19.05

    (.75)

    Inlet Port

    6.75 (17/64) Thru.

    2 Plcs.

    56.64

    (2.23)

    76.20

    (3.00)

    19.05

    (.75)

    Square

    69.85 (2.75) Require

    for Element & Bowl

    Removal

    Torque Bowl to

    20 N.M. (15 lbs-ft) Max.

    Outlet Port

    4.06

    (.16)

    Indicator

    38.10 (1.50) Max. Visual

    49.53 (1.95) Max Electrical

    Head - Top View

    Assembly - Side View

    W331 Specification Illustrations

    Plastic Electrical Housings

    Aluminum Electrical Housings

    Note: The female plug (connector) is tobe furnished by customer.

    Indicator Switch

    Schematic Wiring Diagram

    All dimensions are shown in millimeters [inches]. Applications

    High Pressure Circuits In-Plant Systems

  • 8/13/2019 donaldson visokotlani filteri

    4/86130 Hydraulic Filtration www.buydonaldson.com

    W331Max Flow: 6 gpm (23 lpm)

    High-Performance DT Filter Choices

    W331 Components

    Performance DataW331 Housing Only

    W331 Filter Only W331 High Collapse Filter Only

    Flow Rate (gpm)

    PressureD

    rop

    (psid)

    PressureD

    rop

    (kPa)

    Flow Rate (lpm)

    Flow Rate (gpm)

    Pressure

    Drop

    (psid)

    W331 Bypass Valve

    0 2 4 640

    45

    50

    55

    60

    50 PSID cracking

    0

    10

    20

    30

    40

    50

    60

    0 5 10 15 20

    0

    2

    4

    6

    8

    10

    0 1 2 3 4 5 6

    5m

    8m

    12m

    0

    10

    20

    30

    40

    50

    60

    0 5 10 15 20

    0

    2

    4

    6

    8

    10

    0 1 2 3 4 5 6

    P

    ressureD

    rop

    (kPa)

    Flow Rate (lpm)

    Pre

    ssureD

    rop

    (psid)

    Flow Rate (gpm)

    0

    10

    20

    30

    40

    50

    60

    0 5 10 15 20

    0

    2

    4

    6

    8

    10

    0 1 2 3 4 5 6

    PressureDrop

    (kPa)

    Flow Rate (lpm)

    PressureD

    rop

    (psid)

    Flow Rate (gpm)

    5m

    14m

    Media x(c) = 1000 Length Donaldson Comments

    Type Rating based on ISO 16889 in mm Part No.

    DT Synteq Synthetic 5 m 3.44 87.3 P572298 AN6235-3A

    8 m 3.44 87.3 P572299 AN6235-3A

    12 m 3.44 87.3 P572300 AN6235-3A

    5 m 3.44 87.3 P572301 AN6235-3A, High collapse

    12 m 3.44 87.3 P572302 AN6235-3A, High collapse

    Filter Notes All Donaldson W331 filters utilize glass fiber media with an epoxy-based resin system for the ultimate in chemical compatibility.

    All Donaldson W331 filters are potted with epoxy-based adhesives.

    Standard collapse W331 designs are double wire-backed using epoxy-coated steel mesh for maximum pleat support and dirt capacity.

    High collapse designs are double wire-backed using stainless steel mesh.

    High collapse designs are also potted into machined aluminum endcaps for greater filter integrity in critical applications.

    Vitonseals are standard on all Donaldson W331 filters. Vitonis a registered trademark of E. I. DuPont de Nemours and Company.

  • 8/13/2019 donaldson visokotlani filteri

    5/86Hydraulic Filtration 1www.buydonaldson.com

    W331Max Flow: 6 gpm (23 lpm)

    Housing Ordering Guide

    Table 5 (Primary)

    Indicator Style and Setting

    CODE DP INDICATOR STYLE & SETTING

    D Electrical/visual 35 psid

    E Electrical/visual 100 psid

    G Electrical/visual 35 psid w/TL

    J P indicator plug

    L Visual indicator 35 psid M Visual indicator 35 psid

    w/ TL and surge

    N Electrical/visual 35 psid

    w/12" 3 wire flying lead

    O Visual indicator 100 psid

    P Visual indicator 100 psid

    w/ TL and surge

    R Electrical switch 35 psid

    S Electrical/visual 100 psid

    w/12" 3 wire flying lead

    T Electrical switch 100 psid

    W Electrical/visual 100 psid

    w/TL

    Y Electrical/visual 35 psid

    w/TL and surge

    Z Electrical/visual 100 psid

    w/TL and surge

    TL (thermal lockout)

    Table 1

    Filter Assembly

    CODE DESCRIPTION

    W331 Assembly

    Table 2

    Filter Collapse Options

    CODE DESCRIPTION

    1 150 psid for housing

    w/bypass valve

    4 3000 psi for housing

    w/o bypass valve

    Table 3

    Port Size Options

    CODE PORT SIZE

    O SAE-8 O-ring

    Table 4

    Bypass Setting Options

    CODE BYPASS SETTING

    1 Non-bypass

    4 50 psid

    Note: Use option 1 code only with3000 psid collapse filter.

    W331 1 O 4 L N B

    TABLE 1 TABLE 2 TABLE 3 TABLE 4 TABLE 5 TABLE 6

    Metric Porting Available

    Change W331 to G331

    Porting code O becomes 1/2"ISO 228 BSPP

    Table 5 (Secondary)

    Receptacle Options

    CODE ELECTRICAL STYLE

    B Brad Harrison(5-pin)

    H Hirschmann(4-pin)

    N None, for visual DPindicator

    Table 6

    Seal Options

    CODE MATERIAL

    B Buna-N

    V Viton

    Filter

    Assembly

    Service

    FilterFilters ordered separately. See previous page for filter options.

    LEAD TIME NOTE:

    This product is configured with the specifications andfeatures of your choice. Please contact your Donaldsonsales representative for lead time details.

    Media Ratings

    Western Filter elements have been replaced by

    Donaldson DT high-performance cartridges.

    WESTERN DONALDSONMEDIA CODE DT MEDIA

    03 5m DT Synteq Synthetic

    05 8m DT Synteq Synthetic

    10 12m DT Synteq Synthetic

    For a complete filter interchange, visit

    crossreference.donaldson.com.

    METRIC PORTING AVAILABLE

    Brad Harrison is a registered trademark of Woodhead Industries, Inc.

    Hirschmann is a registered trademark of Richa rd Hirschmann of America Inc.

    Buna-Nand Vitonare registered trademarks of E. I. DuPont de Nemours an

  • 8/13/2019 donaldson visokotlani filteri

    6/86132 Hydraulic Filtration www.buydonaldson.com

    Working Pressures to: 2000 psi13,790 kPa

    137.9 bar

    Rated Static Burst to: 4500 psi 31,030 kPa 310.3 bar

    Flow Range to: 20 gpm 75 lpm

    HPK02 In-Line Cartridge Filters

    Beta Rating Performance to

  • 8/13/2019 donaldson visokotlani filteri

    7/86Hydraulic Filtration 1www.buydonaldson.com

    Head - Top ViewAssembly - Side View

    HPK02Max Flow: 20 gpm (75 lpm)

    HPK02 Specification Illustrations

    All dimensions are shown in inches [millimeters].

    HPK02with Visual Service Indicator

    HPK02with AC/DC Electrical Service Indicator

    Applications

    High Pressure Circuits In-Plant Systems

    Meets HF2 Specification

    Mobile Equipment Power Steering Circuits

    Servo Valve Circuits

  • 8/13/2019 donaldson visokotlani filteri

    8/86134 Hydraulic Filtration www.buydonaldson.com

    HPK02 Components

    HPK02Max Flow: 20 gpm (75 lpm)

    High-Performance DT Filter Choices

    Filter Notes All Donaldson DT filters utilize glass fiber media with an epoxy-based resin system for the ultimate in chemical compatibility.

    All Donaldson DT filters are potted with epoxy-based adhesives.

    Standard collapse DT designs are double wire-backed using epoxy-coated steel mesh for maximum pleat support and dirtcapacity. High collapse designs are double wire-backed using stainless steel mesh.

    High collapse designs are also potted into machined aluminum endcaps for greater filter integrity in critical applications.

    Vitonseals are standard on all Donaldson DT filters. Vitonis a registered trademark of E. I. DuPont de Nemours and Company.

    Standard Filter Choices

    Filter Notes* Utilizes DT Synteq synthetic media Refer to the table in the Technical Reference Guide for fluid compatibility with our filter media.

    If filtering petroleum-based oil, filters with seals made of Buna-Nare appropriate for most applications.

    If filtering diester, phosphate ester fluids, water glycol, water/oil emulsions, or HWCF over 150F/83C,use filters with seals made of fluorocarbon, such as Viton.

    Donaldson "high collapse" filters, with their steel end caps and wire-backed media, are rated towithstand up to 3000 psi/ 20,700 kPa before collapsing.

    The fluorocarbon seal/high collapse filters also use epoxy potting and media seam seals for addedchemical compatibility.

    Some part numbers are offered with the same beta ratings to maintain customer ordering patterns.

    VitonandBuna-Nregistered trademarks of E. I. DuPont de Nemours and Company.

    Media x(c) = 1000 Length Donaldson CommentsType Rating based on ISO 16889 in mm Part No.

    Synteq Synthetic 5 m 4.37 111 P167180* Fluorocarbon Seal, High Collapse

    5 m 8.12 203 P167182* Fluorocarbon Seal, High Collapse

    7 m 4.37 111 P169429 Buna-NSeal

    7 m 4.37 111 P165041 Buna-N Seal

    7 m 8.12 203 P167838 Buna-N Seal

    7 m 8.12 203 P165043 Buna-N Seal

    9 m 4.37 111 P165006 Buna-N Seal

    9 m 8.12 203 P165015 Buna-N Seal

    12 m 4.37 111 P167181* Fluorocarbon Seal, High Collapse12 m 8.12 203 P167183* Fluorocarbon Seal, High Collapse

    23 m 4.37 111 P165136 Buna-N Seal

    23 m 8.12 203 P165138 Buna-N Seal

    Media x(c) = 1000 Length Donaldson Comments

    Type Rating based on ISO 16889 in mm Part No.

    DT Synteq Synthetic

  • 8/13/2019 donaldson visokotlani filteri

    9/86Hydraulic Filtration 1www.buydonaldson.com

    Housing Choices

    Length Part No.

    short P167443

    long P167452

    Port Size Bypass Rating Indicators1 Part No.

    Head Choices

    SAE-12 O-Ring 50 psi/3.5 bar Visual indicator, left side P167728

    SAE-12 O-Ring No bypass Visual indicator, left side P167730

    Notes on Indicators1

    Donaldson uses the inlet port as the reference point. "Left side," for instance, means that the indicator mounts on theside of the filter head that is on your left when you face the inlet port.

    Replacement Indicator Only

    Indicator Choices

    Part No. Description

    P567458Visual/Electrical indicator with thermal lockoutand surge, 35 psid/2.4 bar

    P567459

    Visual/Electrical indicator, with thermal lockout

    and surge 70 psid/4.8 bar

    P567456Pop-Up Visual Indicator, with thermal lockoutand surge 35 psid/2.4 bar

    P567457Pop-Up Visual Indicator, with thermal lockoutand surge 70 psid/4.8 bar

    P569636 Pop-Up Visual Indicator, 35 psid/2.4 bar

    P569637 Pop-Up Visual Indicator, 70 psid/4.8 bar

    P569638 Visual/Electrical Indicator, 35 psid/2.4 bar

    P569639 Visual/Electrical Indicator, 70 psid/4.8 bar

    P164315 Visual Indicator, bar style, 35 psid/2.4 bar

    P166603 Visual Indicator, bar style, 70 psid/4.8 bar

    P166134 Blanking plate

    HPK02Max Flow: 20 gpm (75 lpm)

    Indicator Mounting Block

    Part No. Description

    P573495 Mounting Block Assembly

    Part No.

    Use withBypass ValvePressure of: Description

    P569634 50 psi / 3.5 bar

    35 psi/2.4 bar indicator kitHirschmann receptacle115 VAC/28 VDC, 2 amps

    P569635 90 psi / 6.2 bar

    70 psi/4.8 bar indicator kitHirschmann receptacle115 VAC/28 VDC, 2 amps

    P567986 50 psi / 3.5 bar

    35 psi/2.4 bar indicator kit withthermal lockout and surge control,Hirschmann receptacle, 115 VAC/28VDC, 2 amps, 4 pin DIN 43650

    P567987 90 psi / 6.2 bar

    70 psi/4.8 bar indicator kit withthermal lockout and surge control,Hirschmann receptacle, 115 VAC/28VDC, 2 amps, 4 pin DIN 43650

    Part No.

    Use withBypass ValvePressure of: Description

    P569632 50 psi / 3.5 bar35 psi/2.4 bar indicator kitauto reset pop-out button

    P569633 90 psi / 6.2 bar70 psi/4.8 bar indicator kitauto reset pop-out button

    P567988 50 psi / 3.5 bar

    35 psi/2.4 bar indicator kitauto reset pop-out button withthermal lockout and surge control

    P567989 90 psi / 6.2 bar

    70 psi/4.8 bar indicator kit*auto reset pop-out button withthermal lockout and surge control

    AC/DC Visual/Electrical Service Indicators

    All kits include indicator with mounting block

    Visual Service Indicators

    Service Indicator Kits

  • 8/13/2019 donaldson visokotlani filteri

    10/86136 Hydraulic Filtration www.buydonaldson.com

    Performance Data

    HPK02Max Flow: 20 gpm (75 lpm)

    HPK02 Housing Only

    0

    3

    6

    9

    12

    15

    0 5 10 15 20 250

    20

    40

    60

    80

    100

    0 20 40 60 80

    SAE-12

    0

    5

    10

    15

    20

    25

    0 5 10 15 20 250

    30

    60

    90

    120

    150

    0 20 40 60 80

    0

    5

    10

    15

    20

    25

    0 5 10 15 20 250

    30

    60

    90

    120

    150

    0 20 40 60 80

    HPK02 Standard 8" Filter Only

    Flow Rate (gpm)

    Pressure

    Drop

    (psid)

    Pressure

    Drop

    (kPa)

    Flow Rate (lpm)

    Flow Rate (gpm)

    Pressure

    Drop

    (psid)

    Pressure

    Drop

    (kPa)

    Flow Rate (lpm)

    Flow Rate (gpm)

    Pressure

    Drop

    (psid)

    Pressure

    Drop

    (kPa)

    Flow Rate (lpm)

    HPK02 Standard 4" Filter Only

    0

    5

    10

    15

    20

    25

    0 5 10 15 20 250

    30

    60

    90

    120

    150

    0 20 40 60 80

    0

    5

    10

    15

    20

    25

    0 5 10 15 20 250

    30

    60

    90

    120

    150

    0 20 40 60 80

    0

    5

    10

    15

    20

    25

    0 5 10 15 20 250

    30

    60

    90

    120

    150

    0 20 40 60 80

    0

    5

    10

    15

    20

    25

    0 5 10 15 20 250

    30

    60

    90

    120

    150

    0 20 40 60 80

  • 8/13/2019 donaldson visokotlani filteri

    11/86Hydraulic Filtration 1www.buydonaldson.com

    HPK02 Service Parts

    Optional MountingBlock Assembly

    P573495(Optional Position)

    Replacement FilterSee Filter Choice Tables

    HousingSee Housing AssemblyChoice Table

    Pop Up VisualIndicator

    See Option Table(Includes Indicator

    O-Ring P161315Fluorocarbon,

    Mounting Block& Hardware)

    Electrical /Visual Indicator

    See Option Table(Includes Indicator

    O-Ring P161315Fluorocarbon,

    Mounting Block& Hardware)

    Blanking Plate P166134Includes O-Ring P161315

    Fluorocarbon & Hardware)

    SealP167268 Fluorocarbon

    Visual Service Indicator

    (Includes O-ring P161315Fluorocarbon & Hardware)Max Temp 180F (82C) / 345 kPaP164315 Normal Flow Model

    O-Ring(Size 006)P161315 Fluorocarbon

    O-Ring(Size 006)

    P161315 Fluorocarbon

    O-Ring(Size 006)

    P161315 Fluorocarbon

    Head AssembliesSee Head AssemblyOptions Table

    Optional MountingBlock Assembly

    P573495(Primary Position)

    Pop Up VisualIndicator

    See Option Table(Includes Indicator

    O-Ring P161315Fluorocarbon,

    Mounting Block& Hardware)

    Electrical /Visual Indicator

    See Option Table(Includes Indicator

    O-Ring P161315Fluorocarbon,

    Mounting Block& Hardware)

    HPK02Max Flow: 20 gpm (75 lpm)

  • 8/13/2019 donaldson visokotlani filteri

    12/86138 Hydraulic Filtration www.buydonaldson.com

    W341Max Flow: 20 gpm (75 lpm)

    W341 In-Line Cartridge Filters

    Working Pressures to: 3000 psi20,700 kPa207 bar

    Rated Static Burst to: 7,500 psi51,700 kPa517 bar

    Fatigue Pressure Rating: 1500 psi10,300 kPa103 bar

    Flow Range to: 20 gpm75 lpm

    Beta Rating Performance to 5(c)=1000

    Porting Size Options SAE-12 O-ring

    Assembly Weight 7.28": 5.3 lbs / 2.4 kg 10.03": 5.7 lbs / 2.6 kg

    Replacement Filter Lengths 5.27" / 133.8mm 8.00" / 203.2mm

    Standard Bypass Ratings 50 psi / 345 kPa / 3.5 bar No Bypass

    Operating Temperatures -45 to 250F (-43 to 121C)

    Filter Collapse Ratings 150 psi / 1034 kPa / 10.3 bar (standard) 3000 psi / 20,700 kPa / 206.8 bar (high collapse)

    The W341 in line filter assembly offers all aluminum construction with a positive sealing poppet type bypass for

    reliability and zero leakage. Donaldson DT high-performance 4-layer media is offered in four different media grades.

    The differential pressure indicator line is designed to work with the wide assortment of bypass valves. Thermal

    lockout and surge control are two key features incorporated in many of the differential pressure indicators.

    Aluminum head and housing

    Compact design for use with servo or proportional valve

    Positive sealing poppet for zero leakage

    Features

  • 8/13/2019 donaldson visokotlani filteri

    13/86Hydraulic Filtration 1www.buydonaldson.com

    W341Max Flow: 20 gpm (75 lpm)

    Differential Indicators: Indicators are designed to actuate at approximately 80% of bypass valve cracking pressure. It is recommendedthat an indicator with a bypass setting of 100 psid is used with a non-bypass housing.

    Surge Control: This optional feature is used to dampen pressure surges or spikes to avoid premature actuation of the indicator. Surgecontrol delays the indicator response.

    Thermal Lockout: The Thermal Lockout prevents premature signaling of a bypass condition created by viscous fluid during cold start-ups.Normal indicator actuation capability is resumed once the operating temperature of the fluid reaches approximately 80F / 27C.

    Note: The female plug (connector) is to

    be furnished by customer.

    W341 Specification Illustrations

    Head - Top View

    Assembly - Side View

    Inlet Port

    54.9(2.16)

    Outlet Port

    63.5 (2.50) Min. RequiredFor Bowl and Element

    Removal

    Refer to Model Code(Assembly Length)

    63.5(2.50)

    IN OUT

    V isual- 38.1 Max. (1.50)Electrical- 49.53 Max. (1.95)

    P Indicator

    .250-20UNC-2B ThdX 12.7 (.50) Min. Thd Depth2 Plcs

    101.6(4.00)

    19.1(.75)

    76.2(3.00)

    30.2(1.19)

    24.4(.96)

    Plastic Electrical Housings

    Aluminum Electrical Housings

    Note: The female plug (connector) is tobe furnished by customer.

    Indicator Switch

    Schematic Wiring Diagram

    All dimensions are shown in millimeters [inches].

    Refer to Filter Choices(Assembly Length)

    Applications

    High Pressure Circuits In-Plant Systems

  • 8/13/2019 donaldson visokotlani filteri

    14/86140 Hydraulic Filtration www.buydonaldson.com

    W341Max Flow: 20 gpm (75 lpm)

    High-Performance DT Filter ChoicesW341 Components

    Filter Notes

    All Donaldson DT filters utilize glass fiber mediawith an epoxy-based resin system for theultimate in chemical compatibility.

    All Donaldson DT filters are potted with epoxy-based adhesives.

    Standard collapse DT designs are double wire-backed using epoxy-coated steel mesh formaximum pleat support and dirt capacity.

    High collapse designs are double wire-backedusing stainless steel mesh.

    High collapse designs are also potted intomachined aluminum endcaps for greater filter

    integrity in critical applications. Vitonseals are standard on all Donaldson DT

    filters. Vitonis a registered trademark of E. I.DuPont de Nemours and Company.

    Performance Data

    W341 Housing Only

    Flow Rate (gpm)

    Pressure

    Drop(psid)

    W341 Bypass Valve

    0 4 8 12 16 20

    40

    45

    50

    55

    60

    W341 8" Filter OnlyDT-N, 7.81"/198.3mm

    W341 5" High Collapse Filter OnlyDT-N-HC, 5.06"/128.6mm

    W341 8" High Collapse Filter OnlyDT-N-HC, 7.81"/198.3mm

    0

    10

    20

    30

    40

    50

    60

    0 20 40 60

    0

    2

    4

    6

    8

    10

    0 5 10 15 20

    PressureD

    rop(kPa)

    Flow Rate (lpm)

    PressureD

    rop(psid)

    Flow Rate (gpm)

    W341 5" Filter OnlyDT-N, 5.06"/128.6mm

    0

    10

    20

    30

    40

    50

    60

    0 10 20 30

    2

    4

    6

    8

    10

    00

    2 4 6 8 10

    PressureD

    rop(k

    Pa)

    Flow Rate (lpm)

    PressureD

    rop

    (p

    sid)

    Flow Rate (gpm)

    5m

    8m

    14m

    25m

    0

    10

    20

    30

    40

    50

    60

    0 20 40 60

    0

    2

    4

    6

    8

    10

    0 5 10 15 20

    PressureD

    rop

    (kP

    a)

    Flow Rate (lpm)

    PressureD

    rop

    (psid)

    Flow Rate (gpm)

    5m8m

    14m

    25m

    0

    10

    20

    30

    40

    50

    60

    0 10

    20 30

    0

    2

    4

    6

    8

    10

    0 2 4

    6 8 10

    PressureD

    rop

    (kP

    a)

    Flow Rate (lpm)

    PressureD

    ro

    p

    (psid)

    Flow Rate (gpm)

    5m

    14m

    0

    10

    20

    30

    40

    50

    60

    0 20 40 60

    0

    2

    4

    6

    8

    10

    0 5 10 15 20

    PressureD

    rop

    (kPa)

    Flow Rate (lpm)

    PressureD

    rop

    (psid)

    Flow Rate (gpm)

    5m14m

    Media x(c) = 1000 Length Donaldson Comments

    Type Rating based on ISO 16889 in mm Part No.

    DT Synteq Synthetic 5 m 5.27 133.8 P567065 DT-N-1-5UM

    8 m 5.27 133.8 P567066 DT-N-1-8UM

    12 m 5.27 133.8 P567067 DT-N-1-14UM

    23 m 5.27 133.8 P567068 DT-N-1-25UM

    5 m 8.00 203.2 P567069 DT-N-2-5UM

    8 m 8.00 203.2 P567070 DT-N-2-8UM

    12 m 8.00 203.2 P567071 DT-N-2-14UM

    23 m 8.00 203.2 P567072 DT-N-2-25UM

    5 m 5.27 133.8 P572303 DT-N-HC-1-5UM, High collapse

    12 m 5.27 133.8 P572304 DT-N-HC-1-14UM, High collapse

    5 m 8.00 203.2 P572305 DT-N-HC-2-5UM, High collapse

    12 m 8.00 203.2 P572306 DT-N-HC-2-14UM, High collapse

  • 8/13/2019 donaldson visokotlani filteri

    15/86Hydraulic Filtration 1www.buydonaldson.com

    W341Max Flow: 20 gpm (75 lpm)

    Housing Ordering Guide

    Table 5 (Primary)

    Indicator Style and Setting

    CODE DP INDICATOR STYLE & SETTING

    D Electrical/visual 35 + 5 psid

    E Electrical/visual 100 + 12 psid

    G Electrical/visual 35 + 5 psid

    w/TL

    J No indicator L Visual indicator 35 + 5 psid

    M Visual indicator 35 + 5 psid

    w/ TL and surge

    N Electrical/visual 35 + 5 psid

    w/12" 3 wire flying lead

    O Visual indicator 100 + 12 psid

    P Visual indicator 100 + 12 psid

    w/ TL and surge

    R Electrical switch 35 + 5 psid

    S Electrical/visual 100 + 12 psid

    w/12" 3 wire flying lead

    T Electrical switch 100 + 12 psid

    W Electrical/visual 100 + 12 psid

    w/TL

    Y Electrical/visual 35 + 5 psid

    w/TL and surge

    Z Electrical/visual 100 + 12 psid

    TL (thermal lockout)

    Table 1

    Filter Assembly

    CODE DESCRIPTION

    W341 Assembly

    Table 2

    Filter Collapse Options

    CODE DESCRIPTION

    1 150 psid for housing

    w/bypass valve

    4 3000 psid for housing

    without bypass valve

    Table 3

    Port Size Options

    CODE PORT SIZE

    A SAE-12 O-ring

    Table 4

    Bypass Setting Options

    CODE BYPASS SETTING

    1 Non-bypass

    4 50 psid

    Table 7

    Assembly & Filter Length

    CODE (LGTH) FILTER LENGTH

    1 (7.28") 5.3"2 (10.03") 8.0"

    W341 1 A 1 M N B 1

    TABLE 1 TABLE 2 TABLE 3 TABLE 4 TABLE 5 TABLE 6 TABLE 7

    Metric Porting Available

    Change W341 to G341

    Porting code A becomes G-3/4"

    ISO 228 BSPP

    Table 5 (Secondary)

    Receptacle Options

    CODE ELECTRICAL STYLE

    B Brad Harrison(5-pin)

    H Hirschmann(4-pin)

    N None, for visual DPindicator

    Table 6

    Seal Options

    CODE MATERIAL

    B Buna-N

    V Viton

    Filter

    Assembly

    Service

    FilterFilters ordered separately. See previous page for filter options.

    LEAD TIME NOTE:

    This product is configured with the specifications andfeatures of your choice. Please contact your Donaldsonsales representative for lead time details.

    Brad Harrison is a registered trademark of Woodhead Industries, Inc.

    Hirschmann is a registered trademark of Richa rd Hirschmann of America Inc.

    Buna-Nand Vitonare registered trademarks of E. I. DuPont de Nemours an

    Media Ratings

    Western Filter elements have been replaced by

    Donaldson DT high-performance cartridges.

    WESTERN DONALDSONMEDIA CODE DT MEDIA

    03 5m DT Synteq Synthetic

    05 8m DT Synteq Synthetic

    10 12m DT Synteq Synthetic

    20 23m DT Synteq Synthetic

    For a complete filter interchange, visit

    crossreference.donaldson.com.

    METRIC PORTING AVAILABLE

  • 8/13/2019 donaldson visokotlani filteri

    16/86142 Hydraulic Filtration www.buydonaldson.com

    W440 In-Line Cartridge Filters

    Working Pressures to: 4000 psi27,600 kPa276 bar

    Rated Static Burst to: 10,000 psi69,000 kPa690 bar

    Fatigue Pressure Rating: 2450 psi16,900 kPa169 bar

    Flow Range to: 20 gpm75 lpm

    The W440 filter assembly can be manifold mounted to the hydraulic system. The size and material configuration

    are well-suited for todays demanding proportional and servo valve applications. Our standard housing drain plug

    helps relieve system pressure during filter change-outs. DT 4-layer media is offered in a variety of designs. Five

    different media grades are offered. Donaldson filters core collapse options range from 150 to 3,000 psi. The

    differential pressure indicator line is designed to work with a wide assortment of bypass valves. Thermal lockout

    and surge control are two key features incorporated in many of the differential pressure indicators.

    Beta Rating Performance to

  • 8/13/2019 donaldson visokotlani filteri

    17/86Hydraulic Filtration 1www.buydonaldson.com

    Manifold Mounting

    Bypass Valve

    (Subplate Only)

    Inlet and Outlet PortO-rings (-117) supplied

    101.60

    (4.00)

    50.80(2.00)

    81.28

    (3.20)

    46.23

    (1.82)

    17.02

    (.67)

    31.75

    (1.25)

    Drill 8.89 (.350) Hole Thru

    25.40 (1.00) C'Bore

    17.53 (.69) Hole

    4 Plcs.

    110.74

    (4.36)

    44.45

    (1.75)

    31.75

    (1.25)

    88.90

    (3.50)

    104.65

    (4.12)

    52.32

    (2.06)

    15.75

    (.62)

    Visual-86.61 Max.(3.41)

    Elec.-98.04 Max.

    (3.86)

    P Indicator

    2 Plcs

    INLET

    OUTLET

    Differential Indicators: Indicators are designed to actuate at approximately 80% of bypass valve cracking pressure. It is recommendedthat an indicator with a bypass setting of 100 psid is used with a non-bypass housing.

    Surge Control: This optional feature is used to dampen pressure surges or spikes to avoid premature actuation of the indicator. Surgecontrol delays the indicator response.

    Thermal Lockout: The Thermal Lockout prevents premature signaling of a bypass condition created by viscous fluid during cold start-ups.Normal indicator actuation capability is resumed once the operating temperature of the fluid reaches approximately 80F / 27C.

    Note: The female plug (connector) is to

    be furnished by customer.

    Dimensions: millimeters/(inches)

    W440Max Flow: 20 gpm (75 lpm)

    W440 Specification Illustrations

    Head - Top View

    Assembly - Side View

    6.73 (.265) Drill Hole Thru.

    Mounting Holes, 2 Plcs.

    Required ForElement and

    63.50(2.50) Min.

    Drain Plug

    9/16-18UNF

    Thread

    SAE-6 Straight

    69.34 (2.73)

    Inlet Port

    79.37

    (3.125)

    P Indicator

    25.40

    (1.00)

    Visual-92.71 Max.

    (3.65)

    Electrical-104.14 Max.

    (4.10)

    Refer To

    Model Code

    (Assembly Length)

    Torque Bowl To

    20 N.M(15 Lbs-Ft)Max

    O utlet

    Port

    Bowl Removal.

    IN

    OUT

    Plastic Electrical Housings

    Aluminum Electrical Housings

    Note: The female plug (connector) is tobe furnished by customer.

    Indicator Switch

    Schematic Wiring Diagram

    All dimensions are shown in millimeters [inches].

    Refer to Filter Choices(Assembly Length)

  • 8/13/2019 donaldson visokotlani filteri

    18/86144 Hydraulic Filtration www.buydonaldson.com

    Performance Data

    W440Max Flow: 20 gpm (75 lpm)

    High-Performance DT Filter Choices

    Filter Notes All Donaldson DT filters utilize glass fiber media with an epoxy-based resin system for the ultimate in chemical compatibility.

    All Donaldson DT filters are potted with epoxy-based adhesives.

    Standard collapse DT designs are double wire-backed using epoxy-coated steel mesh for maximum pleat support and dirt capacity.

    High collapse designs are double wire-backed using stainless steel mesh.

    High collapse designs are also potted into machined aluminum endcaps for greater filter integrity in critical applications.

    Vitonseals are standard on all Donaldson DT filters. Vitonis a registered trademarks of E. I. DuPont de Nemours and Company.

    W440 Components

    0

    5

    10

    15

    20

    25

    0 5 10 15 20 250

    30

    60

    90

    120

    150

    0 20 40 60 80

    0

    5

    10

    15

    20

    25

    0 5 10 15 20 250

    30

    60

    90

    120

    150

    0 20 40 60 80

    0

    5

    10

    15

    20

    25

    0 5 10 15 20 250

    30

    60

    90

    120

    150

    0 20 40 60 80

    0

    5

    10

    15

    20

    25

    0 5 10 15 20 250

    30

    60

    90

    120

    150

    0 20 40 60 80

    W440 4" DT Filter OnlyDT-9020-4, 4.41"/111.9mm

    W440 8" DT Filter OnlyDT-9020-8, 8.28"/210.3mm

    W440 4" DT Filter OnlyDT-9021-4, 4.46"/113.2mm

    W440 8" DT Filter OnlyDT-9021-8, 8.16"/207.2mm

  • 8/13/2019 donaldson visokotlani filteri

    19/86Hydraulic Filtration 1www.buydonaldson.com

    Housing Ordering Guide

    Table 5 (Primary)

    Indicator Style and Setting

    CODE DP INDICATOR STYLE & SETTING

    A Visual indicator 70 psid w/TL & surge

    B Electrical/visual 70 psid

    w/TL and surge

    D Electrical/visual 35 psid

    E Electrical/visual 100 psid G Electrical/visual 35 psid w/TL

    I Visual indicator 70 psid

    J DP indicator plug

    L Visual indicator 35 psid

    M Visual indicator 35 psid

    w/ TL and surge

    N Electrical/visual 35 psid

    w/12" 3-wire flying lead

    O Visual indicator 100 psid

    P Visual indicator 100 psid

    w/TL and surge

    R Electrical switch 35 psid

    S Electrical/visual 100 psid

    w/12" 3-wire flying lead

    T Electrical switch 100 psid

    U Electrical switch 70 psid

    W Electrical/visual 100 psid w/TL

    Y Electrical/visual 35 psid

    w/TL and surge

    Z Electrical/visual 100 psid

    w/TL and surge

    TL (thermal lockout)

    Table 1

    Filter Assembly

    CODE DESCRIPTION

    W440 Assembly

    Table 2

    Filter Collapse Options

    CODE DESCRIPTION

    1 150 psid for housing

    w/bypass valve

    4 3000 psi for housing

    w/o bypass valve

    Table 3

    Port Size Options

    CODE PORT SIZE

    A SAE-12 O-ring

    S Manifold mounting

    Table 4

    Bypass Setting Options

    CODE BYPASS SETTING

    1 Non-bypass

    4 50 psid

    6 90 psid

    Note: Use option 1 code only with3000 psid collapse filter.

    Table 7

    Assembly & Filter Length

    CODE (LGTH) FILTER LENGTH 1 (7.18") 4.4"

    2 (10.8") 8.2"*

    *HF2

    W440 1 S 1 J N B 1

    TABLE 1 TABLE 2 TABLE 3 TABLE 4 TABLE 5 TABLE 6 TABLE 7

    Metric Porting Available

    Change W440 to G440

    Porting code A becomes G-3/4"ISO 228 BSPP

    Table 5 (Secondary)

    Receptacle Options

    CODE ELECTRICAL STYLE

    B Brad Harrison(5-pin)

    H Hirschmann(4-pin)

    N None, for visual DPindicator

    Filter

    Assembly

    Service

    Filter

    W440Max Flow: 20 gpm (75 lpm)

    Filters ordered separately. See previous page for filter options.

    LEAD TIME NOTE:

    This product is configured with the specifications andfeatures of your choice. Please contact your Donaldsonsales representative for lead time details.

    Brad Harrison is a registered trademark of Woodhead Industries, Inc.

    Hirschmann is a registered trademark of Richard Hirschmann of America Inc.

    Buna-Nand Vitonare registered trademarks of E. I. DuPont de Nemours and Company.

    Media Ratings

    Western Filter elements have been replaced byDonaldson DT high-performance cartridges.

    WESTERN DONALDSONMEDIA CODE DT MEDIA

    01

  • 8/13/2019 donaldson visokotlani filteri

    20/86146 Hydraulic Filtration www.buydonaldson.com

    FPK02 In-Line Cartridge Filters

    Standard Bypass Ratings 87 psi/ 600 kPa / 6 bar 87 psiBypass with reverse-flow

    check valve No Bypass

    Operating Temperatures -20F to 250F / -29C to 120C

    Filter Collapse Ratings 290 psi/ 2000 kPa / 20 bar (standard) 3000 psi/ 20,700 kPa / 207 bar

    (high collapse)

    Beta Rating Performance to

  • 8/13/2019 donaldson visokotlani filteri

    21/86Hydraulic Filtration 1www.buydonaldson.com

    Indicator PlugRemove plug to

    install visual or

    electrical indicator.

    46.0

    94

    3.7

    42

    83.4

    M8 X 17 2X

    .91

    3.28

    23.0

    1.81

    1.7

    OUTLETINLET

    4.47

    113.5

    Head - Top View

    Head - Side View

    M8 x1.25

    x .55 Full THD

    [14} 2-PLCS

    All dimensions above are shown in inches [millimeters]

    FPK02Max Flow: 25 gpm (95 lpm)

    Assembly - Side View

    90.0

    332.5

    13.09

    HOUSING

    HOUSING

    231.5

    9.11

    1.61

    41.0

    3.54

    Short Housing

    Long Housing

    FPK02 Specification Illustrations

    All dimensions are shown in inches [millimeters]. Applications

    High Pressure Circuits In-Plant Systems

    Meets HF2 Specification Mobile Equipment Power Steering Circuits Servo Valve Circuits

  • 8/13/2019 donaldson visokotlani filteri

    22/86148 Hydraulic Filtration www.buydonaldson.com

    FPK02 Components

    NOTE:Indicator port is machined and plugged. Replace plug with indicatorof choice: P171945 (visual) or P761056 (electrical).

    SAE-12 O-Ring 87 psi / 6 bar P762766

    SAE-12 O-Ring 87 psi / 6 bar P762767

    with reverse-flow

    check valveSAE-12 O-Ring No Bypass P762768

    Head ChoicesHead ChoicesPort Size Bypass Rating Part No.

    Housing ChoicesLength Part(in.) No.

    4.4" filter P762769

    8.2" filter P762770

    RFC

    Reverse FlowCheck Schematic

    FPK02Max Flow: 25 gpm (95 lpm)

    High-Performance DT Filter Choices

    Filter Notes All Donaldson DT filters utilize glass fiber media with an epoxy-based resin system for the ultimate in chemical compatibility.

    All Donaldson DT filters are potted with epoxy-based adhesives.

    Standard collapse DT designs are double wire-backed using epoxy-coated steel mesh for maximum pleat support and dirt capacity.

    High collapse designs are double wire-backed using stainless steel mesh.

    High collapse designs are also potted into machined aluminum endcaps for greater filter integrity in critical applications.

    Vitonseals are standard on all Donaldson DT filters. Vitonis aregistered trademark of E. I. DuPont de Nemours and Company.

    Media x(c) = 1000 Length Donaldson Comments

    Type Rating based on ISO 16889 in mm Part No.

    DT Synteq Synthetic

  • 8/13/2019 donaldson visokotlani filteri

    23/86Hydraulic Filtration 1www.buydonaldson.com

    FPK02Max Flow: 25 gpm (95 lpm)

    Filter Notes* Utilizes DT Synteq synthetic media Refer to the table in the Technical Reference Guide for fluid compatibility with our filter media.

    If youre filtering petroleum-based oil, filters with seals made of Buna-N are appropriate for most applications.

    If youre filtering diester, phosphate ester fluids, water glycol, water/oil emulsions, and HWCF over 150F/83C, usefilters with seals made of fluorocarbon, such as Vitonfrom DuPont Dow Elastomers, or Fluorelfrom 3M Company.

    Donaldson "high collapse" filters, with their steel end caps and wire-backed media, are rated to withstand up to 3000psi/ 20,700 kPa before collapsing.

    The fluorocarbon seal/high collapse filters also use epoxy potting and media seam seals for added chemicalcompatibility.

    Some part numbers are offered with the same beta ratings to maintain customer ordering patterns.

    VitonandBuna-Nregistered trademarks of E. I. DuPont de Nemours and Company.

    Standard Filter Choices

    Media x(c) = 1000 Length Donaldson Comments

    Type Rating based on ISO 16889 in mm Part No.

    Synteq Synthetic 5 m 4.37 111 P167180* Fluorocarbon Seal, High Collapse

    5 m 8.12 203 P167182* Fluorocarbon Seal, High Collapse

    7 m 4.37 111 P169429 Buna-NSeal

    7 m 4.37 111 P165041 Buna-N Seal

    7 m 8.12 203 P167838 Buna-N Seal

    7 m 8.12 203 P165043 Buna-N Seal

    9 m 4.37 111 P165006 Buna-N Seal

    9 m 8.12 203 P165015 Buna-N Seal

    12 m 4.37 111 P167181* Fluorocarbon Seal, High Collapse

    12 m 8.12 203 P167183* Fluorocarbon Seal, High Collapse

    23 m 4.37 111 P165136 Buna-N Seal

    23 m 8.12 203 P165138 Buna-N Seal

  • 8/13/2019 donaldson visokotlani filteri

    24/86150 Hydraulic Filtration www.buydonaldson.com

    Performance Data

    FPK02Max Flow: 25 gpm (95 lpm)

    FPK02 Standard 8" Filter Only8.12"/203mm

    FPK02 Housing Only

    FPK02 Standard 4" Filter Only4.37"/111mm

    Flow Rate (gpm)

    Pressure

    Drop

    (psid)

    Pressure

    Drop

    (kPa)

    Flow Rate (lpm)

    Flow Rate (gpm)

    Pressure

    Drop

    (psid)

    Pressure

    Drop

    (kPa)

    Flow Rate (lpm)

    Flow Rate (gpm)

    Pressure

    Drop

    (psid)

    Pressure

    Drop

    (kPa)

    Flow Rate (lpm)

    0

    3

    6

    9

    12

    15

    0 5 10 15 20 25

    0

    20

    40

    60

    80

    100

    0 20 40 60 80

    0

    5

    10

    15

    20

    25

    0 5 10 15 20 250

    30

    60

    90

    120

    150

    0 20 40 60 80

    0

    5

    10

    15

    20

    25

    0 5 10 15 20 250

    30

    60

    90

    120

    150

    0 20 40 60 80

    SAE-12

    0

    5

    10

    15

    20

    25

    0 5 10 15 20 250

    30

    60

    90

    120

    150

    0 20 40 60 80

    0

    5

    10

    15

    20

    25

    0 5 10 15 20 250

    30

    60

    90

    120

    150

    0 20 40 60 80

    0

    5

    10

    15

    20

    25

    0 5 10 15 20 250

    30

    60

    90

    120

    150

    0 20 40 60 80

    0

    5

    10

    15

    20

    25

    0 5 10 15 20 250

    30

    60

    90

    120

    150

    0 20 40 60 80

  • 8/13/2019 donaldson visokotlani filteri

    25/86Hydraulic Filtration 1www.buydonaldson.com

    When installing the FPK02 housing onto an installed head, torque it to 15 ft-lbs./2.1 kg-m.

    FPK02 Service Parts

    FPK02Max Flow: 25 gpm (95 lpm)

    - oil before assembling

    Filter

    Housing

    Head

    Plugremove only wheninstalling indicator.

    AC/DC ElectricalIndicatorP761056

    5 bar, 72.5 psid

    Visual IndicatorP1719455 bar, 72.5 psid

    O-Ring 2-140P173382Non-stock item

    G 1/2"threads

    SERVICE PARTS NOTE:Some service parts may not be stocked. Please contact yourDonaldson sales representative for lead time details.

    Back-up RingP173380Non-stock item

  • 8/13/2019 donaldson visokotlani filteri

    26/86152 Hydraulic Filtration www.buydonaldson.com

    W613Max Flow: 35 gpm (130 lpm)

    W613 In-Line Cartridge Filters

    Working Pressures to: 6500 psi44,800 kPa448 bar

    Rated Static Burst to: 20,000 psi138,000 kPa1380 bar

    Fatigue Pressure Rating: 3250 psi22,400 kPa224 bar

    Flow Range to: 35 gpm130 lpm

    Beta Rating Performance to

  • 8/13/2019 donaldson visokotlani filteri

    27/86Hydraulic Filtration 1www.buydonaldson.com

    W613Max Flow: 35 gpm (130 lpm)

    Differential Indicators: Indicators are designed to actuate at approximately 80% of bypass valve cracking pressure. It is recommendedthat an indicator with a bypass setting of 100 psid is used with a non-bypass housing.

    Surge Control: This optional feature is used to dampen pressure surges or spikes to avoid premature actuation of the indicator. Surgecontrol delays the indicator response.

    Thermal Lockout: The Thermal Lockout prevents premature signaling of a bypass condition created by viscous fluid during cold start-ups.Normal indicator actuation capability is resumed once the operating temperature of the fluid reaches approximately 80F / 27C.

    Note: The female plug (connector) is to

    be furnished by customer.

    W613 Specification Illustrations

    Head - Top View

    Assembly - Side View

    Outlet Port

    33.27 Hex

    (1.31)

    Drain Plug9/16-18 UNF

    SAE 6 Straight Thread

    Refer to

    Model Code

    (Assembly Length)

    Vi sual- 38.1 (1.50) Max.

    Electrical- 49.53 (1.95) Max.

    63.5 Min.

    (2.50)Required For Bowl

    and Element Removal

    50.8

    (2.00)

    69.3

    (2.73)

    Inlet Port

    P Indicator

    l

    i l . . .

    l i l . . .

    ..

    .

    .

    .

    .

    .

    .

    .

    .

    .

    .

    . i .

    i l

    l

    l l

    i

    l

    .

    .

    i l

    i

    l

    l

    i l . . .

    l i l . . .

    . i .

    .

    i l

    l l

    .

    .

    .

    .

    l

    i

    l

    i l . . .

    l i l . . .

    57.2

    (2.25)

    28.4

    (1.12)

    94.5

    (3.72)

    47.2

    (1.86)

    139.7

    (5.50)

    97.0

    (3.82)

    7/16-14 UNC-2B Thd

    .70 Min. Thd Depth

    Mounting Hole

    4 Plcs

    Bleed Plug

    7/16-20UNF

    SAE-4 Straight Thread

    Plastic Electrical Housings

    Aluminum Electrical Housings

    Note: The female plug (connector) is tobe furnished by customer.

    Indicator Switch

    Schematic Wiring Diagram

    All dimensions are shown in millimeters [inches].

    Refer to Filter Choices(Assembly Length)

    Applications

    High Pressure Circuits In-Plant Systems

  • 8/13/2019 donaldson visokotlani filteri

    28/86154 Hydraulic Filtration www.buydonaldson.com

    W613Max Flow: 35 gpm (130 lpm)

    High-Performance DT Filter ChoicesW613 Components

    Performance Data

    Filter Notes All Donaldson DT filters utilize glass fiber media with an epoxy-based resin system for the ultimate in chemical compatibility.

    All Donaldson DT filters are potted with epoxy-based adhesives.

    Standard collapse DT designs are double wire-backed using epoxy-coated steel mesh for maximum pleat support and dirt capacity.

    High collapse designs are double wire-backed using stainless steel mesh.

    High collapse designs are also potted into machined aluminum endcaps for greater filter integrity in critical applications.

    Vitonseals are standard on all Donaldson DT filters. Vitonis a registered trademarks of E. I. DuPont de Nemours and Company.

    W613 4" DT Filter OnlyDT-9800-4, 4"/102mm

    W613 4" DT Filter OnlyDT-9801-4, 4"/102mm

    W613 8" DT Filter OnlyDT-9801-8, 8"/203mm

    W613 Housing Only

    Flow Rate (gpm)

    Pressure

    Drop

    (psid)

    0

    0

    4

    8

    12

    16

    20

    2010 30 40

    SAE-12

    SAE-16

    1" Flg. Mt.

    0

    20

    40

    60

    80

    100

    120

    140

    160

    0 40 80 120 160 200

    0

    5

    10

    15

    20

    25

    0 10 20 30 40 50 60

    PressureD

    rop

    (kPa)

    PressureD

    rop

    (kPa)

    Flow Rate (lpm)

    PressureD

    rop

    (psid)

    0

    20

    40

    40 50 60

    60

    80

    100

    120

    140

    160

    0 40 80 120 160 200

    0

    5

    10

    15

    20

    25

    0 10 20 30

    Flow Rate (lpm)

    PressureD

    rop

    (psid)

    Flow Rate (gpm)

    Flow Rate (gpm)

    0

    20

    40

    60

    80

    100

    120

    140

    160

    0 40 80 120 160 200

    0

    5

    10

    15

    20

    25

    0 10 20 30 40 50 60

    PressureD

    rop

    (kPa)

    Flow Rate (lpm)

    PressureD

    rop

    (psid)

    Flow Rate (gpm)

    0

    20

    40

    60

    80

    100

    120

    140

    160

    0 40 80 120 160 200

    0

    5

    10

    15

    20

    25

    0 10 20 30 40 50 60

    PressureD

    rop

    (kPa)

    Flow Rate (lpm)

    PressureD

    rop

    (psid)

    Flow Rate (gpm)

    5m

  • 8/13/2019 donaldson visokotlani filteri

    29/86Hydraulic Filtration 1www.buydonaldson.com

    W613Max Flow: 35 gpm (130 lpm)

    Housing Ordering Guide

    Table 1

    Filter Assembly

    CODE DESCRIPTION

    W613 Assembly

    Table 2

    Filter Collapse Options

    CODE DESCRIPTION 1 150 psid for housing

    w/bypass valve

    4 3000 psid for housing

    without bypass valve

    Table 3

    Port Size Options

    CODE PORT SIZE

    A SAE-12 O-ring

    B SAE-16 O-ring

    F 1" SAE 4-Bolt FlangeCode 61

    M 1" SAE 4-Bolt Flange

    Code 62

    Table 4

    Bypass Setting Options

    CODE BYPASS SETTING

    1 Non-bypass

    4 50 psid

    6 90 psid

    Table 7

    Assembly & Filter Length

    CODE (LGTH) FILTER LENGTH

    1 (8.10") 4.4"

    2 (11.75") 8.2"

    W613 1 B 4 M N B 2

    TABLE 1 TABLE 2 TABLE 3 TABLE 4 TABLE 5 TABLE 6 TABLE 7

    Metric Porting Available

    Change W613 to G613

    Porting code A becomes 3/4"ISO 228 BSPP

    Porting code B becomes 1"ISO 228 BSPP

    Porting code F becomes 1" SAE 4 boltflange with M10 mounting threads

    Porting code M becomes 1" SAE 4 boltflange with M12 mounting threads

    Table 5 (Secondary)

    Receptacle Options

    CODE ELECTRICAL STYLE

    B Brad Harrison(5-pin)

    H Hirschmann(4-pin)

    N None, for visual DPindicator

    Table 6Seal Options

    CODE MATERIAL

    B Buna-N

    V Viton

    Table 5 (Primary)

    Indicator Style and Setting

    CODE DP INDICATOR STYLE & SETTING

    A Visual indicator 70 + 10 psid

    w/TL and surge

    B Electrical/visual 70 + 10 psid

    w/TL and surge

    D Electrical/visual 35 + 5 psid

    E Electrical/visual 100 + 12 psid

    G Electrical/visual 35 + 5 psid w/TL

    I Visual indicator 70 + 10 psid

    J No indicator

    L Visual indicator 35 + 5 psid

    M Visual indicator 35 + 5 psid

    w/ TL and surge

    N Electrical/visual 35 + 5 psid

    w/12" 3 wire flying lead

    O Visual indicator 100 + 12 psid

    P Visual indicator 100 + 12 psid

    w/TL and surge

    R Electrical switch 35 + 5 psid

    S Electrical/visual 100 + 12 psid

    w/12" 3 wire flying lead

    T Electrical switch 100 + 12 psid

    U Electrical switch 70 + 10 psid

    V Electrical/visual 70 + 10 psid w/TL

    W Electrical/visual 100 + 12 psid

    w/TL

    Y Electrical/visual 35 + 5 psid

    w/TL and surge

    Z Electrical/visual 100 + 12 psid

    w/TL and surge

    TL (thermal lockout)

    Filter

    Assembly

    Service

    FilterFilters ordered separately. See previous page for filter options.

    LEAD TIME NOTE:

    This product is configured with the specifications andfeatures of your choice. Please contact your Donaldsonsales representative for lead time details.

    Media Ratings

    Western Filter elements have been replaced by

    Donaldson DT high-performance cartridges.

    WESTERN DONALDSONMEDIA CODE DT MEDIA

    01

  • 8/13/2019 donaldson visokotlani filteri

    30/86156 Hydraulic Filtration www.buydonaldson.com

    W322Max Flow: 50 gpm (190 lpm)

    W322 In-Line Cartridge Filters

    Working Pressures to: 3000 psi20,700 kPa207 bar

    Rated Static Burst to: 7,500 psi51,700 kPa517 bar

    Fatigue Pressure Rating: 2000 psi13,800 kPa138 bar

    Flow Range to: 50 gpm190 lpm

    Beta Rating Performance to

  • 8/13/2019 donaldson visokotlani filteri

    31/86Hydraulic Filtration 1www.buydonaldson.com

    W322Max Flow: 50 gpm (190 lpm)

    Differential Indicators: Indicators are designed to actuate at approximately 80% of bypass valve cracking pressure. It is recommendedthat an indicator with a bypass setting of 100 psid is used with a non-bypass housing.

    Surge Control: This optional feature is used to dampen pressure surges or spikes to avoid premature actuation of the indicator. Surgecontrol delays the indicator response.

    Thermal Lockout: The Thermal Lockout prevents premature signaling of a bypass condition created by viscous fluid during cold start-ups.Normal indicator actuation capability is resumed once the operating temperature of the fluid reaches approximately 80F / 27C.

    Note: The female plug (connector) is to

    be furnished by customer.

    W322 Specification Illustrations

    Head - Top View

    Assembly - Side Views

    73.15

    (2.88)

    SAE-12 Plug

    SAE-24 Access Plug

    (Ball Valve)

    Outlet Check Valve

    Typ 2 Plcs

    69.85 Min.

    (2.75)

    Clearance to

    Remove Element

    and Bowl

    97.54

    (3.84)

    164.34

    (6.47)

    Max

    Torque Bowl to Head

    20 N.M(15 Lbs-Ft)Max

    Drain Plug

    9/16-18UNF

    (SAE-6 Plug)

    152.40

    (6.00)

    P Indicator

    292.61

    (11.52)

    Bleed Plug

    7/16-20UNF

    (SAE-4 Plug)

    Inlet Port

    (Outlet Port at

    Opposite Side.)

    Refer To

    Model Code

    (Assembly Length)

    .

    .

    .

    .

    .

    i l l

    .

    .

    .

    .

    ..

    ..

    .

    .

    l l

    l

    .

    .

    i i i i

    : l i i

    .

    .

    l

    l

    ll l

    l l

    l

    . i .

    .

    l

    l

    l

    .

    .

    .

    .

    l

    .

    i l

    l

    .

    .

    i

    .

    .

    l l

    l

    l

    l

    i i .

    l

    l

    243.84

    (9.60)

    152.40

    (6.00)

    7/16-14UNC-2B Thd.

    Mounting Holes, 4 Plcs

    50.80

    (2.00)

    12.70

    (.50)

    218.40

    (8.60)

    12.70

    (.50)

    254.76

    (10.03)

    Alternate Outlet Port

    (Plugged)

    105.40

    (4.15)

    indicates flow direction

    Note: Handle position

    Plastic Electrical Housings

    Aluminum Electrical Housings

    Note: The female plug (connector) is tobe furnished by customer.

    Indicator Switch

    Schematic Wiring Diagram

    All dimensions are shown in millimeters [inches].

    Refer to Filter Choices(Assembly Length)

    Applications

    High Pressure Circuits In-Plant Systems

  • 8/13/2019 donaldson visokotlani filteri

    32/86158 Hydraulic Filtration www.buydonaldson.com

    W322Max Flow: 50 gpm (190 lpm)

    High-Performance DT Filter ChoicesW322 Components

    Filter Notes All Donaldson DT filters utilize glass fiber media with an epoxy-based resin system for the ultimate in chemical compatibility.

    All Donaldson DT filters are potted with epoxy-based adhesives.

    Standard collapse DT designs are double wire-backed using epoxy-coated steel mesh for maximum pleat support and dirt capacity.

    High collapse designs are double wire-backed using stainless steel mesh.

    High collapse designs are also potted into machined aluminum endcaps for greater filter integrity in critical applications.

    Vitonseals are standard on all Donaldson DT filters. Vitonis a registered trademark of E. I. DuPont de Nemours and Company.

    Performance DataW322 4" DT Filter Only

    DT-9800-4, 4"/102mm

    W322 4" DT Filter OnlyDT-9801-4, 4"/102mm

    W322 8" DT Filter OnlyDT-9801-8, 8"/203mm

    Flow Rate (gpm)

    Pressure

    Drop

    (psid)

    W322 Housing Only

    0

    0

    10

    20

    30

    40

    2010 30 40 50 0

    20

    40

    60

    80

    100

    120

    140

    160

    0 40 80 120 160 200

    0

    5

    10

    15

    20

    25

    0 10 20 30 40 50 60

    PressureD

    rop

    (kPa)

    Flow Rate (lpm)

    PressureD

    rop

    (psid)

    Flow Rate (gpm)

    5m

  • 8/13/2019 donaldson visokotlani filteri

    33/86Hydraulic Filtration 1www.buydonaldson.com

    W322Max Flow: 50 gpm (190 lpm)

    Housing Ordering Guide

    Table 5 (Primary)

    Indicator Style and Setting

    CODE DP INDICATOR STYLE & SETTING

    A Visual indicator 70 psid

    w/TL and surge

    B Electrical/visual 70 psid

    w/TL and surge

    D Electrical/visual 35 psid E Electrical/visual 100 psid

    G Electrical/visual 35 psid w/TL

    I Visual indicator 70 psid

    J P indicator plug

    L Visual indicator 35 psid

    M Visual indicator 35 psid

    w/TL and surge

    N Electrical/visual 35 psid

    w/12" 3-wire flying lead

    O Visual indicator 100 psid

    P Visual indicator 100 psid

    w/TL and surge

    R Electrical switch 35 psid

    S Electrical/visual 100 psid

    w/12" 3-wire flying lead

    T Electrical switch 100 psid

    U Electrical switch 70 psid

    V Electrical/visual 70 psid w/TL

    W Electrical/visual 100 psid w/TL

    Y Electrical/visual 35 psid

    w/TL and surge

    Z Electrical/visual 100 psid

    w/TL and surge

    TL (thermal lockout)

    Table 1

    Filter Assembly

    CODE DESCRIPTION

    W322 Assembly

    Table 2

    Filter Collapse Options

    CODE DESCRIPTION

    1 150 psid for housing

    w/bypass valve

    4 3000 psid for housing

    without bypass valve

    Table 3

    Port Size Options

    CODE PORT SIZE

    B SAE-16 O-ring

    Table 4

    Bypass Setting Options

    CODE BYPASS SETTING

    1 Non-bypass

    4 50 psid

    6 90 psid

    Table 7

    Assembly & Filter Length

    CODE (LGTH) FILTER LENGTH

    1 (6.88") 4.4"

    2 (9.86") 8.2"

    W322 1 B 4 D N B

    TABLE 1 TABLE 2 TABLE 3 TABLE 4 TABLE 5 TABLE 6

    Metric Porting Available

    Change W322 to G322

    Porting code B becomes 1"

    ISO 228 BSPP

    Table 5 (Secondary)

    Receptacle Options

    CODE ELECTRICAL STYLE

    B Brad Harrison(5-pin)

    H Hirschmann(4-pin)

    N None, for visual DPindicator

    Table 6

    Seal Options

    CODE MATERIAL

    B Buna-N

    V Viton

    *Note: Use option 1 code only with

    3000 psid collapse filter.

    2

    TABLE 7

    Filter

    Assembly

    Service

    FilterFilters ordered separately. See previous page for filter options.

    LEAD TIME NOTE:

    This product is configured with the specifications andfeatures of your choice. Please contact your Donaldsonsales representative for lead time details.

    Media Ratings

    Western Filter elements have been replaced by

    Donaldson DT high-performance cartridges.

    WESTERN DONALDSONMEDIA CODE DT MEDIA

    01

  • 8/13/2019 donaldson visokotlani filteri

    34/86160 Hydraulic Filtration www.buydonaldson.com

    W350 In-Line Cartridge Filters

    Features

    Working Pressures to: 3000 psi21,000 kPa210 bar

    Rated Static Burst to: 7500 psi51,700 kPa517 bar

    Fatigue Pressure Rating: 1500 psi10,000 kPa100 bar

    Flow Range to: 50 gpm190 lpm

    The W350 T-type ported series offers flows up to 50 gpm (190 lpm) with 3 bypass options and conforms to

    the HF3 automotive standard. Our standard housing drain plug helps relieve system pressure during filter

    changeouts. DT 4-layer media is offered in a variety of designs. Five different media grades are offered.

    Donaldson filters core collapse options range from 150 to 3,000 psi (10 to 210 bar). The differential pressure

    indicator line is designed to work with the wide assortment of bypass valves. Thermal lockout and surge

    control are two key features incorporated in many of the differential pressure indicators.

    Beta Rating Performance to

  • 8/13/2019 donaldson visokotlani filteri

    35/86Hydraulic Filtration 1www.buydonaldson.com

    Differential Indicators:Indicators are designed to actuate at approximately 80% of bypass valve cracking pressure.

    It is recommended that an indicator with a bypass setting of 100 psid is used with a non-

    bypass housing.

    Surge Control:This optional feature is used to dampen pressure surges or spikes to avoid premature

    actuation of the indicator. Surge control delays the indicator response.

    Thermal Lockout:The Thermal Lockout prevents premature signaling of a bypass condition created by viscous

    fluid during cold start-ups. Normal indicator actuation capability is resumed once the

    operating temperature of the fluid reaches approximately 80F / 27C.

    Note: The female plug (connector) is to

    be furnished by customer.

    W350Max Flow: 50 gpm (190 lpm)

    W350 Specification Illustrations

    Head - Top View

    Assembly - Side View

    123.19

    4.85

    26.92

    1.06

    130.30

    5.13

    HEX32.67

    1.29

    MAX.

    34.80

    1.37

    VISUAL 54.10(2.3)MAX.

    ELECT. 65.53(2.58)MAX.

    P INDICATOR

    BLEED PLUG

    7/16-20UNFSAE-4 STRAIGHT THD

    INLET PORT

    TORQUE BOWL TO20 N.M. (15 LBS-FT) MAX

    DRAIN PLUG9/16-18UNF

    SAE 6 STRAIGHT THD

    OUTLET PORT

    REFER TOMODEL CODE

    (ASSEMBLY LENGTH)

    MIN

    REQ'D FOR ELEMENTAND BOWL REMOVAL

    50.80 2.00

    5/16-18UNC-3B THD.

    2X MOUNTING HOLES

    57.15

    2.25

    28.58

    1.12

    63.50

    2.50

    31.89

    1.26

    33.53

    1.32

    34.92

    1.38

    Plastic Electrical Housings

    Aluminum Electrical Housings

    Note: The female plug (connector) is tobe furnished by customer.

    Indicator Switch

    Schematic Wiring Diagram

    All dimensions are shown in millimeters [inches].

    Refer to Filter Choices(Assembly Length)

  • 8/13/2019 donaldson visokotlani filteri

    36/86162 Hydraulic Filtration www.buydonaldson.com

    High-Performance DT Filter Choices

    Filter Notes All Donaldson DT and DX2 filters utilize glass

    fiber media with an epoxy-based resin systemfor the ultimate in chemical compatibility.

    All Donaldson DT and DX2 filters are potted withepoxy-based adhesives.

    Standard collapse DT designs are double wire-backed using epoxy-coated steel mesh formaximum pleat support and dirt capacity.

    High collapse designs are double wire-backedusing stainless steel mesh.

    High collapse designs are also potted intomachined aluminum endcaps for greater filterintegrity in critical applications.

    Vitonseals are standard on all Donaldson DTand DX2 filters. Vitonis a registered trademarkof E. I. DuPont de Nemours and Company.

    DX2 filters utilize nylon mesh for pleat support.

    W350 Components

    Flow Rate (gpm)

    Pressure

    Drop

    (psid)

    Pressure

    Drop

    (kPa)

    Flow Rate (lpm)

    Flow Rate (gpm)

    Pressure

    Drop

    (psid)

    Pressure

    Drop

    (kPa)

    Flow Rate (lpm)

    W350 Housing Only

    Flow Rate (gpm)

    Pressure

    Drop

    (psid)

    Pressure

    Drop

    (kPa)

    Flow Rate (lpm)

    Flow Rate (gpm)

    Pressure

    Drop

    (psid)

    Pressure

    Drop

    (kPa)

    Flow Rate (lpm)

    Flow Rate (gpm)

    Pressure

    Drop

    (psid)

    Pressure

    Drop

    (kPa)

    Flow Rate (lpm)

    Flow Rate (gpm)

    Pressure

    Drop

    (psid)

    Pressure

    Drop

    (kPa)

    Flow Rate (lpm)

    0

    5

    10

    15

    20

    25

    0 10 20 30 40 50 600

    20

    40

    60

    80

    100

    120

    140

    160

    0 50 100 150 200

    0

    5

    10

    15

    20

    25

    0 10 20 30 40 50 600

    20

    40

    60

    80

    100

    120

    140

    160

    0 50 100 150 200

    0

    5

    10

    15

    20

    25

    0 20 40 60 80 1000

    20

    40

    60

    80

    100

    120

    140

    160

    0 50 100 150 200 250 300 350

    0

    5

    10

    15

    20

    25

    0 20 40 60 80 1000

    20

    40

    60

    80

    100

    120

    140

    160

    0 50 100 150 200 250 300 350

    0

    5

    10

    15

    20

    25

    0 10 20 30 40 500

    20

    40

    60

    80

    100

    120

    140

    160

    0 50 100 150

    5m

  • 8/13/2019 donaldson visokotlani filteri

    37/86Hydraulic Filtration 1www.buydonaldson.com

    Table 1

    Filter Assembly

    CODE DESCRIPTION

    W350 Assembly

    Table 2

    Filter Collapse Options

    CODE DESCRIPTION

    1 150 psid for housing

    w/bypass valve

    4 3000 psi for housing

    w/o bypass valve

    Table 4

    Bypass Setting Options

    CODE BYPASS SETTING

    1 Non-bypass

    3 25 psid

    4 50 psid

    6 90 psid

    Note: Use option 1 code only with3000 psid collapse filter.

    Table 5 (Secondary)

    Receptacle Options

    CODE ELECTRICAL STYLE

    B Brad Harrison(5-pin)

    H Hirschmann(4-pin)

    N None, for visual DPindicator

    Table 7

    Assembly & Filter Length

    CODE (LENGTH) FILTER LENGTH

    1 (8.5") 4.0"

    2 (12.0") 8.0"

    Filter

    Assembly

    Service

    Filter

    W350 1 B 1 J N B 1

    TABLE 1 TABLE 2 TABLE 3 TABLE 4 TABLE 5 TABLE 6 TABLE 7

    Table 5 (Primary)

    Indicator Style and Setting

    CODE DP INDICATOR STYLE & SETTING

    A Visual indicator 70 psid

    w/TL & surge

    B Electrical/visual 70 psid

    w/TL and surge

    C Electrical/visual 15 psid D Electrical/visual 35 psid

    E Electrical/visual 100 psid

    F Electrical/visual 15 psid w/TL

    G Electrical/visual 35 psid w/TL

    H Electrical/visual 15 psidw/12" 3-wire flying lead

    I Visual indicator 70 psid

    J P indicator plug K Visual indicator 15 psid

    L Visual indicator 35 psid

    M Visual indicator 35 psid

    w/ TL and surge N Electrical/visual 35 psid

    w/12" 3-wire flying lead

    O Visual indicator 100 psid

    P Visual indicator 100 psidw/TL and surge

    Q Electrical switch 15 psid

    R Electrical switch 35 psid

    S Electrical/visual 100 psidw/12" 3-wire flying lead

    T Electrical switch 100 psid

    U Electrical switch 70 psid

    W Electrical/visual 100 psid w/TL X Electrical/visual 15 psid

    w/TL and surge

    Y Electrical/visual 35 psidw/TL and surge

    Z Electrical/visual 100 psidw/TL and surge

    TL (thermal lockout)

    Metric Porting Available

    Change W350 to G350

    Porting code B becomes G-1"ISO 228 BSPP

    Table 3

    Port Size Options

    CODE PORT SIZE

    A SAE-12 O-ring

    B SAE-16 O-ring

    Housing Ordering Guide

    W350Max Flow: 50 gpm (190 lpm)

    Filters ordered separately. See previous page for filter options.

    LEAD TIME NOTE:

    This product is configured with the specifications andfeatures of your choice. Please contact your Donaldsonsales representative for lead time details.

    Media Ratings

    Western Filter elements have been replaced by

    Donaldson DT high-performance cartridges.

    WESTERN DONALDSONMEDIA CODE DT MEDIA

    01

  • 8/13/2019 donaldson visokotlani filteri

    38/86164 Hydraulic Filtration www.buydonaldson.com

    Standard Bypass Ratings 50 psi/ 345 kPa / 3.5 bar No Bypass

    Operating Temperatures -20F to 250F / -29C to 121C

    Filter Collapse Ratings 200 psi/ 1380 kPa / 13.8 bar (standard) 3000 psi/ 20,700 kPa / 206.9 bar

    (high collapse)

    Beta Rating Performance to

  • 8/13/2019 donaldson visokotlani filteri

    39/86Hydraulic Filtration 1www.buydonaldson.com

    Head - Top View

    Assembly - Side View

    HPK03Max Flow: 60 gpm (227 lpm)

    HPK03 Specification Illustrations

    All dimensions are shown in inches [millimeters].

    HPK03with Visual Service Indicator

    HPK03with AC/DC Electrical Service Indicator

    Applications

    High Pressure Circuits In-Plant Systems

    Meets HF3 Specification Mobile Equipment Servo Valve Circuits

  • 8/13/2019 donaldson visokotlani filteri

    40/86166 Hydraulic Filtration www.buydonaldson.com

    HPK03 Components

    Filter Notes All Donaldson DT and DX2 filters utilize glass fiber media with an epoxy-based resin system for the ultimate in chemical compatibility.

    All Donaldson DT and DX2 filters are potted with epoxy-based adhesives. DX2 filters utilize nylon mesh for pleat support.

    Standard collapse DT designs are double wire-backed using epoxy-coated steel mesh for maximum pleat support and dirt capacity.

    High collapse designs are double wire-backed using stainless steel mesh.

    High collapse designs are also potted into machined aluminum endcaps for greater filter integrity in critical applications.

    Vitonseals are standard on all Donaldson DT and DX2 filters. Vitonis a registered trademark of E. I. DuPont de Nemours and Company.

    HPK03Max Flow: 60 gpm (227 lpm)

    Filter Notes* Utilizes DT Synteq synthetic media

    SEALS: Filters with seals made of Buna-Nare appropriate for most applications involvingpetroleum oil. Filters with seals made of Viton(a fluoroelastomer) are required when usingdiester, phosphate ester fluids, water glycol, water/oil emulsions, and HWCF (high water contentfluids) over 150F/83C.

    Refer to table in the Technical Reference Guide for fluid compatibility with our filter media.

    Donaldson high collapse filters are physically designed to withstand up to 3000 psi / 20,700 kPabefore collapsing.

    The Vitonhigh collapse filter versions also use epoxy potting and media seam seals for addedchemical compatibility.

    Some part numbers are offered with the same beta ratings to maintain customer ordering patterns.

    VitonandBuna-Nregistered trademarks of E. I. DuPont de Nemours and Company.

    Standard Filter Choices

    High-Performance DT Filter Choices

    Media x(c) = 2 x(c) = 1000 Length Donaldson CommentsType Rating based on ISO 16889 in mm Part No.

    Synteq Synthetic 5 m 8.22 208.8 P167185* Viton, High collapse for no bypass applications

    7 m 8.22 208.8 P167842 Buna-N

    7 m 8.22 208.8 P164594 Buna-N

    9 m 8.22 208.8 P164166 Buna-N

    12 m 8.22 208.8 P167186* Viton, High collapse for no bypass applications

    23 m 8.22 208.8 P164174 Buna-N

    50 m 8.22 208.8 P165319 Buna-N

    Water

    Absorbing 10 m 8.22 208.8 P569528

    Wire Mesh 75 m 8.22 208.8 P162233

    Media x(c) = 1000 Length Donaldson Comments

    Type Rating based on ISO 16889 in mm Part No.

    DT Synteq Synthetic

  • 8/13/2019 donaldson visokotlani filteri

    41/86Hydraulic Filtration 1www.buydonaldson.com

    The P179579housing is 10.73 inches (273mm) long and accepts the filterthat is 8.22 inches (208.8mm) long. It includes a head-to-housing seal.

    Port Size Bypass Rating Indicators1 Part No.

    SAE-16 O-Ring 50 psi / 3.5 bar Visual indicator, left side P166353

    SAE-12 O-Ring 50 psi / 3.5 bar Visual indicator, left side P170489

    SAE-12 O-Ring No bypass Visual indicator, left side P170491

    Head Choices

    Notes1Donaldson uses the inlet port as the reference point. "Left side," for instance, means that the indicator

    mounts on the side of the filter head that is on your left when you face the inlet port.

    Housing ChoicesLength Part(in.) No.

    8.22" filter P179579

    HPK03Max Flow: 60 gpm (227 lpm)

    Replacement Indicator Only

    Part No.

    Use withBypass ValvePressure of: Description

    P569634 50 psi / 3.5 bar

    35 psi/2.4 bar indicator kitHirschmann receptacle115 VAC/28 VDC, 2 amps

    P569635 90 psi / 6.2 bar

    70 psi/4.8 bar indicator kitHirschmann receptacle115 VAC/28 VDC, 2 amps

    P567986 50 psi / 3.5 bar

    35 psi/2.4 bar indicator kit withthermal lockout and surge control,Hirschmann receptacle, 115 VAC/28VDC, 2 amps, 4 pin DIN 43650

    P567987 90 psi / 6.2 bar

    70 psi/4.8 bar indicator kit withthermal lockout and surge control,Hirschmann receptacle, 115 VAC/28VDC, 2 amps, 4 pin DIN 43650

    Part No.

    Use withBypass ValvePressure of: Description

    P569632 50 psi / 3.5 bar35 psi/2.4 bar indicator kitauto reset pop-out button

    P569633 90 psi / 6.2 bar70 psi/4.8 bar indicator kitauto reset pop-out button

    P567988 50 psi / 3.5 bar

    35 psi/2.4 bar indicator kitauto reset pop-out button withthermal lockout and surge control

    P567989 90 psi / 6.2 bar

    70 psi/4.8 bar indicator kit*auto reset pop-out button withthermal lockout and surge control

    AC/DC Visual/Electrical Service Indicators

    All kits include indicator with mounting block

    Visual Service Indicators

    Service Indicator Kits Indicator Choices

    Part No. Description

    P567458Visual/Electrical indicator with thermal lockoutand surge, 35 psid/2.4 bar

    P567459

    Visual/Electrical indicator, with thermal lockout

    and surge 70 psid/4.8 bar

    P567456Pop-Up Visual Indicator, with thermal lockoutand surge 35 psid/2.4 bar

    P567457Pop-Up Visual Indicator, with thermal lockoutand surge 70 psid/4.8 bar

    P569636 Pop-Up Visual Indicator, 35 psid/2.4 bar

    P569637 Pop-Up Visual Indicator, 70 psid/4.8 bar

    P569638 Visual/Electrical Indicator, 35 psid/2.4 bar

    P569639 Visual/Electrical Indicator, 70 psid/4.8 bar

    P164315 Visual Indicator, bar style, 35 psid/2.4 bar

    P166603 Visual Indicator, bar style, 70 psid/4.8 bar

    P166134 Blanking plate

    Indicator Mounting Block

    Part No. Description

    P573495 Mounting Block Assembly

  • 8/13/2019 donaldson visokotlani filteri

    42/86168 Hydraulic Filtration www.buydonaldson.com

    Performance Data

    HPK03Max Flow: 60 gpm (227 lpm)

    HPK03 8" Standard Filter OnlyHPK03 Housing Only

    Flow Rate (gpm)

    Pressure

    Drop

    (psid)

    Pressure

    Drop

    (kPa)

    Flow Rate (lpm)

    Flow Rate (gpm)

    Pressure

    Drop

    (psid)

    Pressure

    Drop

    (kPa)

    Flow Rate (lpm)

    Flow Rate (gpm)

    Pressure

    Drop

    (psid)

    Pressure

    Drop

    (kPa)

    Flow Rate (lpm)

    Flow Rate (gpm)

    Pressure

    Drop

    (psid)

    Pressure

    Drop

    (kPa)

    Flow Rate (lpm)

    Flow Rate (gpm)

    Pressure

    Drop

    (psid)

    Pressure

    Drop

    (kPa)

    Flow Rate (lpm)

    0

    3

    6

    9

    12

    15

    0 12 24 36 48 600

    20

    40

    60

    80

    100

    0 50 100 150 200

    SAE-12

    SAE-16

    0

    4

    8

    12

    16

    20

    0 12 24 36 48 600

    30

    60

    90

    120

    0 50 100 150 200

    0

    5

    10

    15

    20

    25

    0 20 40 60 80 1000

    20

    40

    60

    80

    100

    120

    140

    160

    0 50 100 150 200 250 300 350

    0

    5

    10

    15

    20

    25

    0 20 40 60 80 1000

    20

    40

    60

    80

    100

    120

    140

    160

    0 50 100 150 200 250 300 350

    0

    5

    10

    15

    20

    25

    0 10 20 30 40 500

    20

    40

    60

    80

    100

    120

    140

    160

    0 50 100 150

    WireMesh

    5m8m

    12m

    23m

  • 8/13/2019 donaldson visokotlani filteri

    43/86

  • 8/13/2019 donaldson visokotlani filteri

    44/86170 Hydraulic Filtration www.buydonaldson.com

    W610Max Flow: 50 gpm (189 lpm)

    W610 In-Line Cartridge Filters

    Working Pressures to: 6,000 psi41,368 kPa414 bar

    Rated Static Burst to: 20,000 psi138,000 kPa1380 bar

    Fatigue Pressure Rating: 3,500 psi24,131 kPa241 bar

    Flow Range to: 50 gpm180 lpm

    Beta Rating Performance to

  • 8/13/2019 donaldson visokotlani filteri

    45/86Hydraulic Filtration 1www.buydonaldson.com

    W610Max Flow: 50 gpm (189 lpm)

    Differential Indicators: Indicators are designed to actuate at approximately 80% of bypass valve cracking pressure. It is recommendedthat an indicator with a bypass setting of 100 psid is used with a non-bypass housing.

    Surge Control: This optional feature is used to dampen pressure surges or spikes to avoid premature actuation of the indicator. Surgecontrol delays the indicator response.

    Thermal Lockout: The Thermal Lockout prevents premature signaling of a bypass condition created by viscous fluid during cold start-ups.Normal indicator actuation capability is resumed once the operating temperature of the fluid reaches approximately 80F / 27C.

    Note: The female plug (connector) is to

    be furnished by customer.

    W610 Specification Illustrations

    Head - Top View

    Assembly - Side View

    Plastic Electrical Housings

    Aluminum Electrical Housings

    Note: The female plug (connector) is tobe furnished by customer.

    Indicator Switch

    Schematic Wiring Diagram

    All dimensions are shown in millimeters [inches].

    Manifold Mounting

    Inlet and Outlet PortO-rings (-120) supplied

    69.34

    (2.73)

    61.20(2.41)

    Drain Plug9/16-18UNFSAE 6 Straight Thread

    33.27(1.31)

    Hex

    Bleed Plug7/16-20UNFSAE 4 Straight Thread

    P Indicator

    13.97(.55)

    28.58(1.12)

    57.15(2.25)

    61.21(2.41)

    94.49(3.72) 47.24

    (1.86)

    7/16 -14UNC-2B Thd2 Plcs X 22.35(.88) Deep

    52.32(2.06)

    26.16(1.03)

    38.10(1.50)

    Outlet Port30.23 (1.19) C'Bore Dia

    23.37 (.92) Flow Port Dia

    7/16-14UNC-2B ThdThru 4 Plcs

    77.72 Max(3.06)

    Inlet Port

    63.50 Min (2.50) Req'd For Element And Bowl Removal

    Visual - 38.10 Max (1.50)Electrical - 49.53 Max (1.95

    Refer ToModel Code

    (Assembly Length)

    Inlet Port

    30.23 (1.19) C'Bore Dia21.34 (.84) Flow Port Dia

    Torque Bowl to20 N.M (15 Lbs-Ft) Max

    IN

    65.02(2.56)

    57.15(2.25)

    28.45(1.12)

    94.49(3.72)

    47.24(1.86)

    7/16-14UNC-2BThd Thru 4 Plcs

    Outlet Port

    88.39(3.48)

    Refer to Filter Choices(Assembly Length)

  • 8/13/2019 donaldson visokotlani filteri

    46/86172 Hydraulic Filtration www.buydonaldson.com

    W610Max Flow: 50 gpm (189 lpm)

    High-Performance DT Filter ChoicesW610 Components

    Performance Data

    Filter Notes All Donaldson DT filters utilize glass fiber media with an epoxy-based resin system for the ultimate in chemical compatibility.

    All Donaldson DT filters are potted with epoxy-based adhesives.

    Standard collapse DT designs are double wire-backed using epoxy-coated steel mesh for maximum pleat support and dirt capacity.

    High collapse designs are double wire-backed using stainless steel mesh.

    High collapse designs are also potted into machined aluminum endcaps for greater filter integrity in critical applications.

    Vitonseals are standard on all Donaldson DT filters. Vitonis a registered trademarks of E. I. DuPont de Nemours and Company.

    W610 4" DT Filter OnlyDT-9800-4, 4"/102mm

    W610 4" DT Filter OnlyDT-9801-4, 4"/102mm

    W610 8" DT Filter OnlyDT-9801-8, 8"/203mm

    W610 Housing Only

    Bypass Valve

    0

    20

    40

    60

    80

    100

    120

    140

    160

    0 40 80 120 160 200

    0

    5

    10

    15

    20

    25

    0 10 20 30 40 50 60

    PressureD

    rop

    (kPa)

    PressureD

    rop

    (kPa)

    Flow Rate (lpm)

    PressureD

    rop

    (psid)

    0

    20

    40

    40 50 60

    60

    80

    100

    120

    140

    160

    0 40 80 120 160 200

    0

    5

    10

    15

    20

    25

    0 10 20 30

    Flow Rate (lpm)

    PressureD

    rop

    (psid)

    Flow Rate (gpm)

    Flow Rate (gpm)

    0

    20

    40

    60

    80

    100

    120

    140

    160

    0 40 80 120 160 200

    0

    5

    10

    15

    20

    25

    0 10 20 30 40 50 60

    PressureD

    rop

    (kPa)

    Flow Rate (lpm)

    PressureD

    rop

    (psid)

    Flow Rate (gpm)

    0

    20

    40

    60

    80

    100

    120

    140

    160

    0 40 80 120 160 200

    0

    5

    10

    15

    20

    25

    0 10 20 30 40 50 60

    PressureD

    rop

    (kPa)

    Flow Rate (lpm)

    PressureD

    rop

    (psid)

    Flow Rate (gpm)

    5m

  • 8/13/2019 donaldson visokotlani filteri

    47/86Hydraulic Filtration 1www.buydonaldson.com

    W610Max Flow: 50 gpm (189 lpm)

    Housing Ordering Guide

    Table 1

    Filter Assembly

    CODE DESCRIPTION

    W610 Assembly

    Table 2

    Filter Collapse Options

    CODE DESCRIPTION 1 150 psid for housing

    w/bypass valve

    4 3000 psid for housing

    without bypass valve

    Table 3

    Port Size Options

    CODE PORT SIZE

    A SAE-12 O-ring

    B SAE-16 O-ring

    F 1" SAE 4-Bolt FlangeCode 61

    M 1" SAE 4-Bolt Flange

    Code 62

    S Manifold Mounting

    Table 4

    Bypass Setting Options

    CODE BYPASS SETTING

    1 Non-bypass

    4 50 psid

    6 90 psid

    Table 7

    Assembly & Filter Length

    CODE (LGTH) FILTER LENGTH

    1 (6.75") 4.0"

    2 (10.40") 8.0"

    W610 1 A 4 J N B 1

    TABLE 1 TABLE 2 TABLE 3 TABLE 4 TABLE 5 TABLE 6 TABLE 7

    Metric Porting Available

    Change W610 to G610

    Porting code A becomes G3/4"ISO 228 BSPP

    Porting code B becomes G1"ISO 228 BSPP

    Porting code F becomes 1" SAE 4 boltflange with M10 mounting threads

    Porting code M becomes 1" SAE 4 boltflange with M12 mounting threads

    Table 5 (Secondary)

    Receptacle Options

    CODE ELECTRICAL STYLE

    B Brad Harrison(5-pin)

    H Hirschmann(4-pin)

    N None, for visual DPindicator

    Table 6Seal Options

    CODE MATERIAL

    B Buna-N

    V Viton

    Filter

    Assembly

    Service

    FilterFilters ordered separately. See previous page for filter options.

    LEAD TIME NOTE:

    This product is configured with the specifications andfeatures of your choice. Please contact your Donaldsonsales representative for lead time details.

    Media Ratings

    Western Filter elements have been replaced by

    Donaldson DT high-performance cartridges.

    WESTERN DONALDSONMEDIA CODE DT MEDIA

    01

  • 8/13/2019 donaldson visokotlani filteri

    48/86174 Hydraulic Filtration www.buydonaldson.com

    FPK04 In-Line Cartridge Filters

    The FPK04 T-type ported series offers flows up to 100 gpm (379 lpm) with a bypass option and

    conforms to the HF3 automotive standard.

    Donaldson Synteqmedia is offered in a variety of designs. Upgraded Donaldson high-performance DT

    filters are also offered for superior performance. The differential pressure indicator line is designed to work

    with the wide assortment of bypass valve options.

    Working Pressures to: 4350 psi30,000 kPa300 bar

    Rated Static Burst to: 9135 psi63,000 kPa630 bar

    Flow Range to: 100 gpm379 lpm

    Conforms to HF3 specifications

    High collapse filters available for use

    with non-bypass applicationsWide range of indicator options

    Three housing length options for design flexibility

    Buna-Nseals standard, Vitonavailable

    Head material: cast ironHousing material: steel

    DT Replacement Filter Lengths

    4.56" / 116mm 4.59" / 116.7mm 8.19" / 208mm 8.22" / 208.8mm

    Beta Rating Performance to

  • 8/13/2019 donaldson visokotlani filteri

    49/86Hydraulic Filtration 1www.buydonaldson.com

    13.60 [345.5]

    9.94 [252.5]

    5.59 [142.0]

    5.59 [142.0]

    5.59 [142.0]

    18.37 [466.50]

    Head - Top View

    Assembly - Side View

    FPK04Max Flow: 100 gpm (379 lpm)

    FPK04 Specification Illustrations

    2.24 [57.0]

    3.70 [94.0]

    All dimensions are shown in inches [millimeters]. Applications

    High Pressure Circuits In-Plant Systems

    Meets HF3 Specification Mobile Equipment Servo Valve Circuits

  • 8/13/2019 donaldson visokotlani filteri

    50/86176 Hydraulic Filtration www.buydonaldson.com

    Port Size Bypass Rating Indicators Part No.

    SAE-20 87 psi / 6 bar plugged only P568720

    SAE-20 No bypass plugged only P568721

    Head Choices

    NotesHousings include the head to housing seal.

    Housing Choices Indicator ChoicesFilter Length Part (in.) No.

    4.6" P568722

    8.2" P568723

    12.9" P568724

    Set Point / Type Part No.39 psi/2.7 bar ele N.O. P165194

    39 psi/2.7 bar ele N.C. P167455

    FPK04 ComponentsHigh-Performance DT Filter Choices

    Filter Notes

    All Donaldson DT and DX2 filters utilize glass fibermedia with an epoxy-based resin system for theultimate in chemical compatibility.

    All Donaldson DT and DX2 filters are potted with

    epoxy-based adhesives. Standard collapse DT designs are double wire-

    backed using epoxy-coated steel mesh formaximum pleat support and dirt capacity.

    High collapse designs are double wire-backedusing stainless steel mesh.

    High collapse designs are also potted intomachined aluminum endcaps for greater filterintegrity in critical applications.

    Vitonseals are standard on all Donaldson DTand DX2 filters. Vitonis a registered trademark ofE. I. DuPont de Nemours and Company.

    DX2 filters utilize nylon mesh for pleat support.

    FPK04Max Flow: 100 gpm (379 lpm)

    Media x(c) = 1000 Length Donaldson Comments

    Type Rating based on ISO 16889 in mm Part No.

    DT Synteq Synthetic

  • 8/13/2019 donaldson visokotlani filteri

    51/86Hydraulic Filtration 1www.buydonaldson.com

    Filter Element

    Housing

    Drain Plug

    FPK04 Service Parts

    FPK04Max Flow: 100 gpm (379 lpm)

    Head

    Indicator

    PlugRemove only wheninstalling indicator

    Standard Filter Choices

    Media x(c) = 2 x(c) = 1000 Length Donaldson Comments

    Type Rating based on ISO 16889 in mm Part No.

    Synteq Synthetic

  • 8/13/2019 donaldson visokotlani filteri

    52/86178 Hydraulic Filtration www.buydonaldson.com

    Performance Data

    FPK04Max Flow: 100 gpm (379 lpm)

    FPK04 4" Standard Filter Only4.62"/117.3mm

    FPK04 Housing Only

    Flow Rate (gpm)

    Pressure

    Drop

    (psid)

    Pressure

    Drop

    (kPa)

    Flow Rate (lpm)

    0

    5

    10

    15

    20

    25

    0 10 20 30 40 50 600

    20

    40

    60

    80

    100

    120

    140

    160

    0 50 100 150 200

    FPK04 8" Standard Filter Only8.20"/208.3mm

    Flow Rate (gpm)

    Pressure

    Drop

    (psid)

    Pressure

    Drop

    (kPa)