2
1095 N. Main Street, Bowling Green, Ohio, USA, 43402 Tel: 1-866-354-8546, Fax: (419) 354-9706 E-mail: [email protected] 606 Highway Drive, St.Brieux, SK., Canada, SOK 3V0 Tel: 1-888-750-1700, Fax: (306) 275-4664 E-mail: [email protected] Dryair Solutions 300GTS greenthaw TM system For ground thaw & concrete cure applications designed to operate in colder climates...as low as -40°F (-40°C) Unmatched temperature control The DRYAIR greenthaw TM system gives you almost perfect control over the temperature of your concrete pour. By adjusting the ‘flow reverser controller’ to the recommended schedule, every square foot of your concrete pour will receive the same amount of heat. This means a uniform curing pattern and less likelihood of problems caused by uneven curing. Dryair's ‘even heat’ approach to curing will also reduce the risk of freezing. Large capacity heater The large 301,000 BTU heater provides you with ample BTU’s maximizing heat exchanger capabilites even in the harshest contidions. Unlike conventional systems, the HTF flow reversing system gives you the added advantage of laying out more hose without the need of a second pump. Outstanding combustion reliability DRYAIR's patented CEC system (combustion environment control system) pre-heats the combustion air and fuel to provide the burner with an ideal combustion environment in the widest range of ambient conditions. Wide outside temperature swings don’t faze the DRYAIR ‘300GTS greenthaw system’... it hums right along! Large hose reel capacity The hose reel is capable of carrying a total of 3000 ft. for more thawing or curing capacity. Enclosed trailer offers convenience and ease Dryair's enclosed design not only offers ease of operation and convenience, we also continue to honor our tradition of excellent service access to all components. Greenthaw TM by DRYAIR... maximizing your energy with innovative features. Focused on dramatically reducing fuel consumption making it the most environmentally friendly, cost efficient system on the market today. Trailer dimensions........................188” long x 76” wide x 96” tall Dry Weight ...................................5950 lbs Burner ......................................single stage Fuel ......................................diesel fuel/#1 or 2 heating oil Input capacity ..........................301,000 BTUH, 87.2 KW Output capacity........................255,850 BTUH, 71.5 KW Consumption (100% run time).2.15 US GPH, 8.14 LPH Fuel capacity................................150 US GAL Maximum thawing capacity..........6,000 sq.ft Heating capacity - area................433,154 cu.ft. Heat transfer fluid (HTF) circulation system HTF ......................................non-toxic propylene glycol / water mix Maximum operating temp. .......195°F Operating pressure .................35 PSI Flow ......................................965 GPH HTF flow reversing system......adjustable cycle time Circulation loop length -max ...1,000 ft. Circulation loop length -min .....500 ft. Climate control system Fuel heater ..............................maintains set fuel temperature Combustion air heater .............maintains set combustion air temperature Control & monitoring ....................pump & temperature controls ......................................full gauge panel showing circulation fluid temperatures & pressures, fuel pressures ......................................Multi-light system operation feature for easy system troubleshooting ......................................external operating light Powered hose reel Controls ...................................forward / reverse ......................................foot switch activation Onboard hose - max................3,000 ft. Manifold ......................................detachable, 6-port Optional Generator ................................Kubota GL7000 7KW Diesel

Dryair 300GTS greenthaw system 130313 Dryair 600GTS ... greenthaw system 13… · Title: Dryair 300GTS greenthaw system 130313_Dryair 600GTS greenthaw system 080731.qxd Author: grant

Embed Size (px)

Citation preview

Page 1: Dryair 300GTS greenthaw system 130313 Dryair 600GTS ... greenthaw system 13… · Title: Dryair 300GTS greenthaw system 130313_Dryair 600GTS greenthaw system 080731.qxd Author: grant

1095 N. Main Street, Bowling Green, Ohio, USA, 43402Tel: 1-866-354-8546, Fax: (419) 354-9706 E-mail: [email protected]

606 Highway Drive, St.Brieux, SK., Canada, SOK 3V0 Tel: 1-888-750-1700, Fax: (306) 275-4664 E-mail: [email protected]

Dryair Solutions

300GTSgreenthawTM

systemFor ground thaw & concrete cureapplicationsdesigned to operate in colder climates...aslow as -40°F (-40°C)

Unmatched temperature control The DRYAIR greenthawTM system gives youalmost perfect control over the temperatureof your concrete pour. By adjusting the ‘flow reverser controller’ tothe recommended schedule, every squarefoot of your concrete pour will receive thesame amount of heat. This means a uniformcuring pattern and less likelihood ofproblems caused by uneven curing.Dryair's ‘even heat’ approach to curing willalso reduce the risk of freezing.Large capacity heaterThe large 301,000 BTU heater provides youwith ample BTU’s maximizing heatexchanger capabilites even in the harshestcontidions. Unlike conventional systems, the HTF flowreversing system gives you the addedadvantage of laying out more hose withoutthe need of a second pump.

Outstanding combustionreliabilityDRYAIR's patented CEC system(combustion environment control system)pre-heats the combustion air and fuel toprovide the burner with an ideal combustionenvironment in the widest range of ambientconditions. Wide outside temperature swings don’t fazethe DRYAIR ‘300GTS greenthaw system’... ithums right along!Large hose reel capacityThe hose reel is capable of carrying a totalof 3000 ft. for more thawing or curingcapacity. Enclosed trailer offersconvenience and ease Dryair's enclosed design not only offers easeof operation and convenience, we alsocontinue to honor our tradition of excellentservice access to all components.

GreenthawTM by DRYAIR... maximizing your energy withinnovative features. Focused on dramatically reducing fuelconsumption making it the most environmentally friendly,cost efficient system on the market today.

Trailer dimensions........................188” long x 76” wide x 96” tallDry Weight ...................................5950 lbsBurner ......................................single stage

Fuel ......................................diesel fuel/#1 or 2 heating oilInput capacity ..........................301,000 BTUH, 87.2 KWOutput capacity........................255,850 BTUH, 71.5 KWConsumption (100% run time).2.15 US GPH, 8.14 LPH

Fuel capacity................................150 US GALMaximum thawing capacity..........6,000 sq.ftHeating capacity - area................433,154 cu.ft.Heat transfer fluid (HTF) circulation system

HTF ......................................non-toxic propylene glycol / water mix Maximum operating temp. .......195°FOperating pressure .................35 PSIFlow ......................................965 GPHHTF flow reversing system......adjustable cycle time Circulation loop length -max ...1,000 ft.Circulation loop length -min.....500 ft.

Climate control systemFuel heater ..............................maintains set fuel temperatureCombustion air heater .............maintains set combustion air

temperatureControl & monitoring ....................pump & temperature controls

......................................full gauge panel showing circulationfluid temperatures & pressures, fuelpressures

......................................Multi-light system operation feature foreasy system troubleshooting

......................................external operating lightPowered hose reel

Controls ...................................forward / reverse......................................foot switch activation

Onboard hose - max................3,000 ft.Manifold ......................................detachable, 6-portOptional

Generator ................................Kubota GL7000 7KW Diesel

Page 2: Dryair 300GTS greenthaw system 130313 Dryair 600GTS ... greenthaw system 13… · Title: Dryair 300GTS greenthaw system 130313_Dryair 600GTS greenthaw system 080731.qxd Author: grant

1095 N. Main Street, Bowling Green, Ohio, USA, 43402Tel: 1-866-354-8546, Fax: (419) 354-9706 E-mail: [email protected]

606 Highway Drive, St.Brieux, SK., Canada, SOK 3V0 Tel: 1-888-750-1700, Fax: (306) 275-4664 E-mail: [email protected]

Dryair Solutions Dryair 300GTS greenthaw system 130313 2

GreenthawTM by DRYAIR... maximizing your energy withinnovative features. Focused on dramatically reducing fuelconsumption making it the most environmentally friendly, costefficient system on the market today.

Uniform thaw =energy savings

The Dryair greenthawTM

system maximizes every ounceof the energy it uses bydirecting heat across the thawgrid in a systematic mannerthat results in a uniform thawpattern. Other systems use circulationloops that move fluid in onedirection only. The fluid, asheat transfer occurs, will cooldown as much as 45% as itmoves towards the end of theloop. This will result in anuneven thaw pattern.Therefore, while ground underthe warm end continues to beheated, energy is wasted wellafter it has been thawed due tothe colder end of the loopfalling behind by as much as75%. This forces you to thawfor several days longer...needlessly costing you extratime and fuel.Dryair's ‘patented’ greenthawTM

system maximizes your costlyenergy by reversing fluid flowon a selected schedule. This means that every squarefoot of ground sees the sameamount of energy giving youan almost perfect thawpattern... and more importantly,saving you valuable time andreducing energy requirements.

Temperature gauge readings represent a job’s average HTF temperatures on one zone (hose loop).

A - Temp. gauge readingsB - Zone; hose loopC - Thaw site cross sectionD - Thaw patternE - Goal thaw depthF - Thaw patterns not

achieving the goal thawdepth

Greenthaw by Dryairwith flow reverser technology

180170160

150140

120

100

190200

210

220

230

24040 °F60

80

180170160

150140

120

100

190200

210

220

230

24040 °F60

80

180170160

150140

120

100

190200

210

220

230

24040 °F60

80

180170160

150140

120

100

190200

210

220

230

24040 °F60

80

180170160

150140

120

100

190200

210

220

230

24040 °F60

80

180170160

150140

120

100

190200

210

220

230

24040 °F60

80

Other Systems

180170160

150140

120

100

190200

210

220

230

24040 °F60

80

180170160

150140

120

100

190200

210

220

230

24040 °F60

80

Although thawing iscomplete on the hot,left side ofthe zone, progress isless than satisfactorytowards the cooler,right side ofthe zone.Additional days will berequired to achievesatisfactory results.

'Supply'

'Return'

By reversing fluid flowon a selected schedule,every square foot ofground sees the sameamount of energygiving you an almostperfect thaw pattern.Thaw is uniform andcomplete across thewhole zone.

A

C

C

D

D

B

B

A

E

E

F

SUPPLY/RETURN

175°F

SUPPLY/RETURN

175°F

SUPPLY180°F