Customised solutions for all types of application
A complete range of burners for all fuelsMONOBLOCK 20 - 17000 kWDUOBLOCK 350 - 25000 kW
GAS/LIGHT OIL BURNERS GAS/HEAVY OIL BURNERS DUOBLOCK BURNERS
GAS BURNERSLIGHT OIL BURNERS HEAVY OIL BURNERS
www.ecoflam-burners.com
BURNERS
2014
www.ecoflam-burners.com 3
COMPANY PROFILE 4BURNER APPLICATIONS 4
RANGE OF PRODUCTS 5Designation 8ECOFLAM range - modular delivery system 10
BURNER STRUCTURE 12Gas train composition - EN676 configurations and export 14Gas train - Kit - Accessories assembly to the burner 15Electronic version with Burner Management System 16TS range - Duoblock burners 16
LIGHT OIL BURNERS 18MAX 19MAIOR 21
HEAVY OIL BURNERS 23MAXFLAM 24OILFLAM 24Forced oil preparation ring 26
GAS BURNERS 27MAX GAS 28BLU 33
DUAL FUEL BURNERS (GAS/LIGHT OIL) 41MULTICALOR 43
DUAL FUEL BURNERS (GAS/HEAVY OIL) 48MULTIFLAM 49
GAS TRAIN - KITS - ACCESSORIES 52Gas train: MAX GAS 52Gas train and connection pipe: BLU - MULTICALOR - MULTIFLAM 53Kit and accessories for gas 54Kit and accessories for oil 56Diagnostic tool for Thermowatt control 56Load controller and probes 57Silencer 57
BURNER SELECTION FORM 58
INDEX
www.ecoflam-burners.com4
ECOFLAM Bruciatori S.p.A. is a specialist in combustion technologies and a worldwide brand recognised for the reliability of its burners, the competence of its technical team and the wide offer of customised solutions for heating and industry applications.
ECOFLAM was established in 1973 in Castelfranco Veneto, near Venice in the North East of Italy. Throughout the time ECOFLAM has continued to develop products with constant devotion and determination addressing: Technological Research, Ecology, Energy Saving and Safety.
ECOFLAM Bruciatori S.p.A. since 2005 has been incorporated into the Burners Division of Ariston Thermo Group and today takes advantage of the group synergies and offers a full range of blown air pressure jet burners for all fuels in monoblock and duoblock version up to 25 MW.
ECOFLAM burners ensure high efficiency and reliable operation combined with functional features that reduce installation time and mainte-nance. Manufacturing is carried out in the factory of Resana (Treviso - Italy) in accordance with ISO 9001:2008 and products are distributed worldwide thanks to its network of partners.
HEATING APPLICATIONS
METAL INDUSTRY APPLICATIONS
ASPHALT PLANTS AND BUILDING INDUSTRY APPLICATIONS
INCINERATORS APPLICATIONS AND WASTE INDUSTRY
MODERNISATION OF PLANTS AND OTHER APPLICATIONS
AGRICULTURE APPLICATIONS
FOOD INDUSTRY APPLICATIONS
TEXTILE, GLASS AND CERAMIC INDUSTRY APPLICATIONS
CHEMICAL AND PETROLCHEMICAL INDUSTRY APPLICATIONS
WOOD AND SOLID FUEL APPLICATIONS
BURNER APPLICATIONS
COMPANY PROFILE
www.ecoflam-burners.com 5
MAX 1
MAX 1 Low NOx
MAX 4
MAX 4 Low NOx
MAX 8
MAX 12
MAX 15
MAX 20
MAX 30
MAX P 12
MAX P 15
MAX P 25
MAX P 35
MAX P 450 100
41
36
59
18
18
20
23
47
60
60
77
73
86
105
130
130
190
190
237
300
319
427
546
110
102
166
202
47
200 300 400 500 600 kW
MAXFLAM 10
MAXFLAM 20
MAXFLAM 30
MAXFLAM 30 AB
MAXFLAM 50 AB0 100 200 300 400 500 600 kW
68 136
108 227
170 340
205 410
205 570
MAIOR P 700.1
MAIOR P 800.1
MAIOR P 1000.1
MAIOR P 1200.1
MAIOR P 1500.1
MAIOR P 1800.10 2000 60004000 8000 10000 14000 1800012000 16000 20000 kW
2417 7500
2750 8500
3300 10500
4367 12500
5000 15000
5700 17000
MAIOR P 60
MAIOR P 80
MAIOR P 120
MAIOR P 150.1
MAIOR P 200.1
MAIOR P 300.1
MAIOR P 400.1
MAIOR P 500.1
MAIOR P 600.10 1000 2000 3000 4000 5000 6000 kW
415
474
830
592
710
710
949
1423
1780
1000 3000
1300 3900
1578 5000
1795 5800
2372
OILFLAM 80.1
OILFLAM 120.1
OILFLAM 170.1
OILFLAM 200.1
OILFLAM 300.1
OILFLAM 400.1
OILFLAM 500.1
OILFLAM 600.1
OILFLAM 700.1
OILFLAM 800.1
OILFLAM 1000.1
OILFLAM 1200.1
OILFLAM 1500.1
OILFLAM 1800.10 2000 60004000 8000 10000 14000 1800012000 16000 20000 kW
930
1395
464
682
682 1700
1000 3000
1300 3900
1578 5000
1795 5800
2417 7500
2750 8500
10500
12500
15000
17000
3300
4367
5000
5700
682 2093
LIGHT OIL RANGE
RANGE OVERVIEW
HEAVY OIL RANGE
www.ecoflam-burners.com6
DUAL FUEL (GAS/LIGHT OIL) RANGE
GAS RANGE
MAX GAS 40
MAX GAS 70
MAX GAS 105
MAX GAS 120
MAX GAS 120 AB
MAX GAS 170
MAX GAS 250
MAX GAS 350
MAX GAS 5000 100 200 300 400 500 600 kW
48
70
17
34
49 108
120
120
170
240
350
500
49
40
55
55
100
120
MULTICALOR 45 AB
MULTICALOR 70 AB
MULTICALOR 70 PR-AB
MULTICALOR 100 AB
MULTICALOR 100 PR-AB
MULTICALOR 140 AB
MULTICALOR 140 PR0 200 600400 800 1000 1400 18001200 1600 2000 kW
190 500
250 700
190 700
300 1000
1300
1000
1300
200
400
250
BLU 1700.1
BLU 2000.1
BLU 3000.1
BLU 4000.1
BLU 5000.1
BLU 6000.1
BLU 7000.1
BLU 8000.1
BLU 10000.1
BLU 12000.1
BLU 15000.1
BLU 18000.10 2000 60004000 8000 10000 14000 1800012000 16000 20000 kW
342 1770
1200
1500 5800
1500 7500
2000 8500
10500
13000
15000
17000
2500
2700
3690
4000
5000
414 2150
630 3000
875 3900
BLU 700.1 Low NOx
BLU 1000.1
BLU 1000.1 Low NOx
BLU 1200.1
BLU 1200.1 Low NOx
BLU 1500.1 Low NOx
0 200 600400 800 1000 1400 18001200 1600 2000 kW
270 700
280 875
1200
1100
1550
290
300
260
245 970
MULTICALOR 170.1
MULTICALOR 200.1
MULTICALOR 300.1
MULTICALOR 400.1
MULTICALOR 500.1
MULTICALOR 600.1
MULTICALOR 700.1
MULTICALOR 800.1
MULTICALOR 1000.1
MULTICALOR 1200.1
MULTICALOR 1500.1
MULTICALOR 1800.10 2000 60004000 8000 10000 14000 1800012000 16000 20000 kW
342 1770
1200
1500 5800
1500 7500
2000 8500
10500
13000
15000
17000
2500
2700
3690
4000
5000
414 2150
630 3000
875 3900
www.ecoflam-burners.com 7
DUOBLOCK RANGE
Note: "Oil"/"Gas" indicates the output range for light oil, heavy oil, gas and dual fuel burners.
DUAL FUEL (GAS/HEAVY OIL) RANGE
PLATFORM 260
PLATFORM 280
PLATFORM 320
PLATFORM 380
PLATFORM 630
PLATFORM 710
PLATFORM 800
Min VSD
Min kW
Max kW
Oil 120 300 450 1400
Gas 1500.1 250 300 15505000 kW0 2000 3000 40001000
Min VSD
Min kW
Max kW
Oil 200.1 500 710 2372
Gas 2000.1 350 414 21505000 kW0 2000 3000 40001000
Min VSD
Min kW
Max kW
Oil 600.1 1050 1500 5800
Gas 6000.1 725 1500 580015000 kW0 6000 9000 120003000
Min VSD
Min kW
Max kW
Oil 800.1 1600 2000 8500
Gas 8000.1 1050 2000 8500
Oil 1200.1 2400 2700 13100
Gas 12000.1 1600 2700 1310015000 kW0 6000 9000 120003000
Min VSD
Min kW
Max kW
Oil 1800.1 3200 5700 17000
Gas 18000.1 2100 4000 1700025000 kW0 10000 15000 200005000
Min VSD
Min kW
Max kW
Oil 2500.1 5000 7000 25000
Gas 25000.1 3200 6000 2500025000 kW0 10000 15000 200005000
Min VSD
Min kW
Max kW
Oil 400.1 700 875 3900
Gas 4000.1 500 875 39005000 kW0 2000 3000 40001000
MULTIFLAM 200.1
MULTIFLAM 300.1
MULTIFLAM 400.1
MULTIFLAM 500.1
MULTIFLAM 600.1
MULTIFLAM 700.1
MULTIFLAM 800.1
MULTIFLAM 1000.1
MULTIFLAM 1200.1
MULTIFLAM 1500.1
MULTIFLAM 1800.10 2000 60004000 8000 10000 14000 1800012000 16000 20000 kW
1200
1500 5800
1500 7500
2000 8500
10500
13000
15000
17000
2500
2700
3690
4000
5000
414 2150
630 3000
875 3900
www.ecoflam-burners.com8
BURNER DESIGNATION
ELECTRICAL POWER SUPPLY230-50 230 V, 50 Hz230-50-60 230 V, 50-60 Hz230-400-50 230/400 V, 50 Hz110-50-60 110 V, 50-60 Hz
FUEL- Gas / Light oil / Heavy oilLPG Liquid gasBIOGAS BiogasKER KeroseneB10 Biodiesel
HEAD TYPETC Short headTL Long head
OPERATION TYPE- 1 stage R 1 stage with pre-heaterP 1 stage - soft startPAB 2 stages gas - soft startP 120 AB 2 stages light/heavy oil 120 kg/h - soft startP 120 AB HS 2 stages oil hydraulic system 120 kg/h - soft startZ3 / S3 2 stages with 3 nozzles / 3 stages with 3 nozzlesPR 2 stages progressive mechanicalPR-PAB 2 stages progressive mechanical gas / 2 stages oilMD 2 stages modulating mechanical with PIDE 2 stages modulating electronic
EMISSIONSLN - Low NOx Low NOx Class 3 - Gas EN676 (<80 mg/kWh)- Standard Class 2 - Gas EN676 (<120 mg/kWh)MAX Low NOx Low NOx Class 3 yellow flame (<120 mg/kWh)MAX Standard Class 2 - Oil EN267 (<185 mg/kWh)MAIOR Standard Class 1 - Oil EN267 (<250 mg/kWh)
MODEL SIZE (gas: kW; oil: kg/h)MAX 4 4 kg/h MAIOR 120 120 kg/h MAX GAS 40 40 kWBLU 1200.1 1200 kWMULTICALOR 300.1 300 kg/h - 3000 kW
RANGE NAME + TS Duoblock burner
CONFIGURATION / ADDITIONAL INFOHT High temperatureD D pump version for light oil (max visc. 5°E at 20°C)SGT Separate gas trainNS Without silencer
ELECTRICAL EQUIPMENT (CONTROL BOX)TW ThermowattLFL.../LAL.../LGK... SiemensLMV... Siemens electronicETO Lamtec Etamatic OEMBT3 Lamtec BT300
RANGE NAME BY FUEL TYPEMAX GAS Gas natural - LPGBLU Gas natural - LPGMAX Light oilMAIOR Light oilMAXFLAM Heavy oil (max visc. 50°E at 50°C)OILFLAM Heavy oil (max visc. 50°E at 50°C)MULTICALOR Dual fuel: gas/light oilMULTIFLAM Dual fuel: gas/heavy oil (max visc. 50°E at 50°C)
BLU 1200.1 LN PAB TL SGT 230-50 TW
www.ecoflam-burners.com 9
GAS TRAIN DESIGNATION
GAS TRAIN VALVE MANUFACTURERD DungsK KromschröderS Siemens - LandisH HoneywellB Brahma
GAS TRAIN MATCHING BURNERMAXGAS40-120 Model matching MAX GAS 40-120BLU/MULTI Model matching BLU-MULTICALOR-MULTIFLAM rangeMAXGAS40-120SX Left side connection for MAX GAS 40-120
VALVE NOMINAL DIAMETERRP15 Rp. 1/2" Threaded connectionRP20 Rp. 3/4" Threaded connectionRP25 Rp. 1" Threaded connectionRP32 Rp. 1"1/4 Threaded connectionRP40 Rp. 1"1/2 Threaded connectionRP50 Rp. 2" Threaded connectionDN40 DN40 Flanged connectionDN50 DN50 Flanged connectionDN60 DN60 Flanged connectionDN80 DN80 Flanged connectionDN100 DN100 Flanged connectionDN125 DN125 Flanged connection
MODEL TYPEMBC120 MultiBloc model MBC120MBDLE403 MultiBloc model MBDLE403MBZRDLE410 MultiBloc 2 stages valve model MBZRDLE410VGD20503 Siemens Landis model VGD20503VCS240 Kromschröder model VCS240EG12L Brahma model EG12L
OPERATION TYPE1 1 stage or 2 stages with butterfly valve2 2 stages solenoid valve3 2 stages pneumatic4 2 stages electronic5 2 stages mechanical
KITTC-VPS504VCS
GT - S2 - VGD40 - DN80 - BLU/MULTI
KIT AND ACCESSORIES DESIGNATION
PROBE-WATER130CGTCP-DN80-260/280/320
Kit tightness control VPS504 for VCS gas valve
Water probe up to 0÷130° С
Connection pipe for gas train DN80 platform 260/280/320
OPT / STD / ACS Optional / Standard / Accessory
www.ecoflam-burners.com10
ECOFLAM RANGE
ECOFLAM burners have been designed and built in compliance with all current regulations and directives. All burners comply to the safety and energy saving operation regulations withinthe standard of their respective performance range. The quality is guaranteed by a quality and management system certified in accordance with ISO 9001:2008.
GAS BURNERS AND DUAL FUEL BURNERS
COMPONENT TYPE
ECOFLAM gas and dual fuel burners are delivered in compliance with the applicable standards. Gas train is delivered separately with different configurations. Kits and accessories shall be included in the gas train and in the burner as described in the scope of supply in accordance with the instructions and the local safety regulations and codes of practise.
GAS TRAIN - GTCP - KITS - ACCESSORIES
All gas and dual fuel burners gas trains are delivered separately in different models and configurations. Export configuration gas train completion are available but it is mandatory for the local installer in this case to comply to the local safety regulations. For burners over 1700 kW gas train connection pipe must be ordered.Kits and accessories are managed and delivered separately.
All gas burners are delivered in separate set/box, i.e. burner body including combustion head and separate gas train with separate additional kits and accessories, that shall complete the gas train or the burner according to the applicable standard.Kits and accessories are delivered separately.
All dual fuel burners are delivered in separate set/box, i.e. burner body including combustion head and separate gas train with separate additional kits and accessories, that shall complete the gas train or the burner according to the applicable standard.Kits and accessories are delivered separately.
Configurated and special versions on request with burner selection form.
ISO9001:2008
CB Complete Burner (for light oil or heavy oil)
BBCH Burner Body with Combustion Head (without gas train)
BB Burner Body CH Combustion HeadGTCP Gas Train Connection PipeGT Gas Train (delivered separately)
SV Separate Ventilator for duoblock burner
www.ecoflam-burners.com 11
BURNER SELECTION: the selection of the type of operation and configuration must be done by professional personnel, in order to grant the correct working of the burner. Installation, start-up and maintenance must be carried out by authorised specialists and all applicable guidelines and regulations (including local safety regulations and codes of practise) must be observed.
LIGHT OIL AND HEAVY OIL BURNERS
ECOFLAM oil burners are delivered in compliance with the applicable standards. Additional accessories and options shall be installed by the installer in accordance with the instruction and the local safety regulations and codes of practise.
All light oil burners are delivered complete in one single package, including filter and flexible hoses up to 6 MW.
All heavy oil burners are delivered with electrical pre-heater preassembled into the burner body, including filter and flexible hoses up to 6 MW.
Configurated and special versions on request with burner selection form.
DUOBLOCK BURNERS
ECOFLAM offers selected models/outputs in duoblock version for all the fuels that can be delivered based on the configuration requested (mechanical or electronic) by the customer in order to better fit into the application, providing a customised and more cost effective solution.
!
www.ecoflam-burners.com12
BURNER STRUCTURE
BBCHBURNER BODY with COMBUSTION HEAD
Light oilHeavy oil
BBCH is delivered in one single boxAdditional KIT-ACS to be ordered and delivered separately
GasDual fuel
BBCH - GT - ACS are delivered in separate boxesAdditional KIT-ACS to be ordered and delivered separately
Duoblock BBCH - GT - ACS are delivered in separate boxesSV and additional KIT-ACS to be ordered and delivered separately
Electronic version with BMSBBCH - GT - ACS are delivered in separate boxesAvailable from 2 MW with loosen electrical panel or separate electrical or switch cabinet
GAS GOVERNOR& FILTER
GAS FILTER
FGDR / FS1BGas pressure governor and filter model FGDR,operating pressure range up to 500 mbar
FS1B up to 1 bar
SPRING FGDRFGDR: default spring is neutral for outlet pressurerange 10-30 mbarFor different outlet setting range please change the spring according to our technical documentation
FILTERGas filter to complete VGD gas trains,operating pressure up to 1 bar(suggested as additional for all installations)
GTGAS TRAIN SEPARATE *
Export configurationEN676 completion
* Minimum working pressure = Pressure drop inlcudes “COMBUSTION HEAD + GAS TRAIN + GAS GOVERNOR & FILTER” as per EN676
MultiBlocMB
Gas MultiBloc Dungs: compact double solenoid valve with integrated filter, regulator and minimum pressure switch
SiemensVGD
Double gas valve with actuators and regulator VGD Siemens and minimum pressure switch + ACS gas filterDefault blank spring: head pressure 0...22 mbarWARNING: from BLU 3000.1 - MULTICALOR 300.1 - MULTIFLAM 300.1 change spring and damping
KromschröderVCS
Double solenoid valve VCS Kromschröder and minimum pressure switch + ACS gas governor & filter
Export configuration Export completion gas train depending on the models shall be completed in compliance with local safety regulations.
GTCPGAS TRAINCONNECTING PIPE
Gas train size vs Diameter of the connection
To be included from the platform 280 (≈1700 kW)
WARNING: size and fitting depend on the burner and the gas train selected
BURNER COMPOSITION - SCOPE OF SUPPLY FOR ALL BURNERS INCLUDES THE FOLLOWING PARTS:
www.ecoflam-burners.com 13
DIAGNOSTIC TOOL KITDT-TW Diagnostic tool for Thermowatt control box
TIGHTNESS CONTROL KITTC-...Gas leakage control device for gas trainsAvailable in different models depending on the type of the gas trainCompulsory for EN676 over 1200 kW – 1032000 kcal/h
MAXIMUM GAS PRESSURE SWITCH KITPRES... Maximum gas pressure switch
To be installed in order to comply with the local safety regulations
ADDITIONAL KITS ACCESSORIES KIT - ACS Additional kits and accessories to be installed in order to comply
with the local safety regulations
Configurations can be implemented in the factory from our internal FLEXSHOP
Swirl systemSwirls for blast tube that can reduce flame lenght up to 10-50%, depending on fuel, backpressure and shape of combustion chamberAvailable for different fuel burner head
KITCV Continuous Ventilation Available for different burnerKit for burner with Thermowatt control box
Other Special configurations will be evaluated on request
AFTER SALE SERVICE CONTRACTS
ECOFLAM Service Department can offer start up service contracts
SPARE PARTS ECOFLAM original spare parts
KITS
KITSIL-... Silencer is complementary and can be ordered as a separate KIT Kit available starting from platform 260
KITLPG-... LPG transformation kit for gas burner (see related models and technical documentation for operating gas pressure)
KITADAPT-... Adaptor for gas train connectionMAX GAS range for LPG
KITPOT-... Potentiometer
KITxx-... Other kits: see related pages
ACCESSORIES
ACS Antivibration coupling
ACS Ball valve
ACS Manometer + Push button
ACS Magnetic + Selfcleaning oil filter
ACS Other ACS: see related pages
PID CONTROLLER KITMD-...KITMD-RWF50Modulation of burner can be done also from the PID of the boiler panel
MATCHING PROBE PROBE-... Matching probe for hot water, air, steam
KIT, ACCESSORIES AND CONFIGURATIONS:
For full modulating version: BURNER BODY PR + PID REGULATOR and PROBE
Additional kits and accessories
FLEXSHOP Configurations - Service
www.ecoflam-burners.com14
GAS TRAIN COMPOSITION - EN676 CONFIGURATION AND EXPORTECOFLAM gas trains are delivered separately for all gas and dual fuel burners and are available in different configurations and models:
• EN676 standard gas train + kit/accessories in compliance with EN676;• Export configuration + others additional options to be added by installer in compliance with local safety regulations and codes of practise;• kit and accessories shall be fitted by the installer in accordance with the instructions and the local safety regulations and codes of practise.
PRESSURE DROP includes: “COMBUSTION HEAD + GAS TRAIN + GAS GOVERNOR & FILTER” as per EN676.Backpressure of boiler/application must be added/included in order to have the total minimum pressure drop.
1. Main gas pipe2. Ball valve ACS3. Antivibrating coupling ACS4. Gas governor & filter ACS
EN67
65. Minimum gas pressure switch
Expo
rt GAS TRAIN6. Safety gas valve
7. Working gas valve8. Gas leakage control KITTC *KIT - Maximum gas pressure switch KITPRESACS - Gas train connection pipe GTCP **
1 2 3 4 78 65
1. Main gas pipe2. Ball valve ACS3. Antivibrating coupling ACS5. Minimum gas pressure switch
EN67
6 GAS TRAIN
EN67
66. Safety + Working gas valve7. Gas governor and filter included8. Gas leakage control KITTC *KIT - Maximum gas pressure switch KITPRESACS - Gas train connection pipe GTCP **1 2 3 865
7
1. Main gas pipe2. Ball valve ACS3. Antivibrating coupling ACS5. Minimum gas pressure switch
Expo
rt GAS TRAIN
EN67
66. Safety gas valve + 10. Actuator7. Working gas valve + 11. Actuator8. Gas leakage control KITTC *9. Gas filter ACSKIT - Maximum gas pressure switch KITPRESACS - Gas train connection pipe GTCP **
1 2 3 9 118 105
67
Default blank spring: head pressure 0...22 mbar. Yellow spring: head pressure 15...120 mbarFrom BLU 3000.1 - MULTICALOR 300.1 - MULTIFLAM 300.1 change spring and damping
* EN676 CONFIGURATION: for VCS gas trains gas governor and filter must be included; for VGD filter must be included.KITTC-... Tightness control device (VPS-VDK-LDU) must be included over 1200 kW according to EN676.
** WARNING: from BLU 1700.1 - MULTICALOR 170.1 - MULTIFLAM 300.1, in order to fit the gas train, the corresponding connection pipe must be ordered (GTCP size and fitting depend on the burner and the gas train selected).
!
!
!
Compact double solenoid valve with integrated filter, regulator and minimum pressure switch MB-DLE 407 - MB-DLE 410 - MB-DLE 412 - MB-DLE 415 - MB-DLE 420
Double solenoid valves and minimum pressure switch + ACS gas governor and filter VCS 125 R/LW Rp 1” - VCS 240 R/LW Rp 1”1/2 - VCS 350 R/LW Rp 2”
Double gas valves with actuators and regulator and minimum pressure switch + ACS gas filter VGD 20.503 Rp 2” / VGD 40.065 - 40.080 - 40.100 - 40.125
MULTIBLOC DUNGS
VCS KROMSCHRÖDER
VGD SIEMENS
www.ecoflam-burners.com 15
GAS TRAIN - KIT - ACCESSORIES ASSEMBLY TO THE BURNERHOW TO INSTALL THE GAS TRAIN INTO THE BURNER AND CALCULATE THE OVERALL DIMENSIONS
KIT AND ACCESSORIES
MAX GAS 40 ÷ 250
Gas train withconnection on the top
MAX GAS 350 ÷ 500BLU 700.1 ÷ 1500.1MULTICALOR 45 ÷ 140
Gas train with right hand side connection
BLU 1700.1 ÷ 18000.1MULTICALOR 170.1 ÷ 1800.1MULTIFLAM 300.1 ÷ 1800.1
Gas train with connection at the bottom, right hand side layout (or left with kit)
DUOBLOCK
Gas train with connection at the bottom, right hand side layout (or left with kit)
WARNING: EN676 compulsory kit and accessories must be ordered to comply with the safety regulations. Additional accessories and kits shall be installed by the installer in accordance with the local safety regulations and codes of practise.
* WARNING: from BLU 1700.1 - MULTICALOR 170.1 - MULTIFLAM 300.1:in order to fit the gas train the corresponding connection pipe must be ordered
GAS GOVERNOR/FILTERFGDR - FILTERCompulsory EN676
MAX GAS PRESSURE SWITCHKITPRES50KITPRES150
LPG TRANSFORMATIONKITLPG-MAXGAS...KITLPG-BLU...
TIGHTNESS CONTROLKITTC- ModelCompulsory over 1200 kW
MODULATION KITKITMD-RWF50PROBE-...
!
!
www.ecoflam-burners.com16
ELECTRONIC VERSION WITH BURNER MANAGEMENT SYSTEM
CAN-Bus
PGASmin PGAS
LT
PAIR
TPPOILmax
POILmin
M
BUSmu l t i
TS RANGE - DUOBLOCK BURNERS
Available models for different fuels in standard progressive mechanical configuration with derivative electrical panel.
Electronic version with Burner Management System with separate switch cabinet on request.
Platform Max output range Light oil Heavy oil Gas Gas/Light oil Gas/Heavy oil260 0,8 ÷ 1,5 MW MAIOR 120 OILFLAM 120.1 BLU 1500.1 MULTICALOR 140 -280 1,5 ÷ 2 MW MAIOR 200.1 OILFLAM 200.1 BLU 2000.1 MULTICALOR 200.1 MULTIFLAM 200.1320 3 ÷ 4 MW MAIOR 400.1 OILFLAM 400.1 BLU 4000.1 MULTICALOR 400.1 MULTIFLAM 400.1380 5 ÷ 6 MW MAIOR 600.1 OILFLAM 600.1 BLU 6000.1 MULTICALOR 600.1 MULTIFLAM 600.1630 7 ÷ 9 MW MAIOR 800.1 OILFLAM 800.1 BLU 8000.1 MULTICALOR 800.1 MULTIFLAM 800.1630 10 ÷ 13 MW MAIOR 1200.1 OILFLAM 1200.1 BLU 12000.1 MULTICALOR 1200.1 MULTIFLAM 1200.1710 15 ÷ 18 MW MAIOR 1800.1 OILFLAM 1800.1 BLU 18000.1 MULTICALOR 1800.1 MULTIFLAM 1800.1800 22 ÷ 25 MW Feasibility only on request
SELECTED OUTPUT TO MATCH MAIN BOILERS AND INDUSTRIAL APPLICATION
ECOFLAM offers the electronic range with BMS from 2 MW up to 17 MW in Monoblock and up to 25 MW in Duoblock configuration with electrical panel assembled into the burner or on request with separate switch cabinet.
For all burners the delivery scope is in a modular system, i.e.:
• BBCH: burner body with combustion head;• GT: gas train; • KIT-ACS: kits and accessories to complete
the burner in order to comply with the local safety regulations and codes of practise;
• Heavy oil and dual fuel (gas/heavy oil) are delivered with pre-heater assembled into the burner body or on request in a separate frame/skid;
• SV: separate ventilator for Duoblock version.
www.ecoflam-burners.com 17
INVERTER SYSTEMVSD module is an extension to the BMS and is used for the control of a variable speed drive, that allows electrical comsumption savings, lo-wer noise emissions, gradual fan starting and reduction of mechanical stress.
O2-CO TRIM CONTROLO2-CO control allows the control of the residual oxygen content in order to increase the boiler ef-ficiency.
ModelTurndown ratio VSD
inverterO2-COtrim
Additionalfunctionsstandard with inverter oil side
MAIOR 200.1-1800.1 1÷5 1÷5 1÷5 Kit Kit Flame monitoring
sensors
Communication interfaces
Display interface
OILFLAM 200.1-1800.1 1÷5 1÷5 1÷5 Kit KitBLU 2000.1-18000.1 1÷6 1÷8 1÷5 Kit KitMULTICALOR 200.1-1800.1 1÷6 1÷8 1÷5 Kit KitMULTIFLAM 200.1-1800.1 1÷6 1÷8 1÷5 Kit KitDUOBLOCK 1÷6 1÷8 1÷5 Kit Kit
Flamesensors
TemperaturePressuresensors
Communicationinterface
LeakageSystem
Display Actuators O2 Trim CO Trim VSD Inverter
MONITORING APPLICATIONReliable and safe flame detection system for single and multiple burner furnaces.
RANGE OF OUTPUT WITH BURNER MANAGEMENT SYSTEM
MONOBLOCK - DUOBLOCK RANGE WITH BMSElectronic compound manager for burner has been introduced into ECOFLAM range in order to improve performance and efficiency of modern firing installation. BMS is a compact powerful solution suitable for the control and supervision of single or dual fuel forced draft burners. This system is designed to match an extensive range of components such as flame, temperature and pressure sensors, gas valves, variable speed fan motors and oxygen control that can be managed from different bus interfaces.
BMS solutions are meant to bring the main following benefits:
• significant energy saving in both fuel and electricity;• optimize process performance and minimize costs;• simple commissioning and operating in total safety;• integrated solution with a wide range of communication interfaces;• combustion optimization with O2/CO control;• effective diagnostic and real time status information;• user interface easy to use and program.
www.ecoflam-burners.com18
MAX
- M
ax v
isc. 1
,5°E
at 2
0°C
MAI
OR
- Max
visc
. 1,5
°E a
t 20°
C
LIGHT
OIL
BURN
ERS
MAX
rang
e fo
r lig
ht o
il com
bine
s a h
igh
efficie
ncy
fan
venti
latio
n sy
stem
(HPV
) with
feat
ures
rang
ing
from
eas
y m
atch
ing
on b
oile
rs u
p to
eas
y m
aint
enan
ce a
nd se
t-up.
Th
e ra
nge
is av
aila
ble
in st
anda
rd cl
ass 2
and
Low
NO
x em
issio
n cla
ss
3 (y
ello
w fl
ame)
acc
ordi
ng to
EN2
67.
The
rang
e fit
s sta
ndar
d he
ating
and
light
indu
stry
app
licati
ons.
MAI
OR
rang
e fo
r lig
ht o
il are
ava
ilabl
e in
two
stag
es w
ith h
ydra
ulic
syst
em o
r ser
vom
otor
up
to 3
50 k
g/h
and
from
the
mod
el M
AIO
R 45
in p
rogr
essiv
e op
erati
on th
at ca
n be
turn
ed
in m
odul
ating
with
a P
ID re
gula
tor.
MAI
OR
mod
els o
ver 7
MW
are
ava
ilabl
e on
requ
est b
ased
on
the
confi
gura
tion
requ
este
d (m
echa
nica
l or e
lect
roni
c)
in o
rder
to b
etter
fit i
nto
the
appl
icatio
n an
d pr
ovid
e a
cust
omise
d an
d m
ore
cost
effe
ctive
solu
tion.
DUO
BLO
CK a
nd E
LECT
RON
IC ve
rsio
ns a
re a
vaila
ble
on
requ
est f
or se
lect
ed o
utpu
t to
mat
ch m
ain
boile
rs a
nd
indu
stry
app
licati
on.
All l
ight
oil
burn
ers a
re d
elive
red
com
plet
e in
one
sing
le
pack
age
inclu
ding
filte
r and
flex
ible
hos
es u
p to
6 M
W.
• KI
T Bi
odie
sel
• KI
T W
iela
nd p
lugs
• Lig
ht o
il pum
p un
it on
requ
est
• PI
D m
odul
ating
KIT
and
pro
be•
Diag
nosti
c too
l for
TW
cont
rol b
ox•
Sile
ncer
(sta
rting
from
pla
tform
260
)
• CV
: Con
tinuo
us ve
ntila
tion
vers
ion
• HT
: Hig
h te
mpe
ratu
re ve
rsio
n•
D pu
mp:
light
oil w
ith m
ax v
iscos
ity 5
°E a
t 20°
C•
OEM
and
spec
ial a
pplic
ation
vers
ion
only
on
requ
est
KIT
- ACS
(see
ded
icate
d pa
ges)
AVAI
LABL
E CO
NFI
GURA
TIO
NS
ON
REQ
UES
T
All b
urne
rs 2
30-4
00V/
50Hz
are
fact
ory
test
ed a
t 400
V/50
Hz
thre
e-ph
ase.
If m
ain
supp
ly is
thre
e-ph
ase
230V
/50H
z see
in
stru
ction
man
ual f
or a
djus
tmen
ts a
nd m
odifi
catio
ns.
!
www.ecoflam-burners.com 19
LIGHT
OIL
BURN
ERS
MO
DEL
OU
TPU
T [k
W]
FLO
W R
ATE
[kg/
h]BL
AST
TUBE
CODE
MIN
MAX
MIN
MAX
MAX
1 L
ow N
Ox
TW -
1/23
0V/5
0-60
Hz17
,635
,51,
53
TC31
4271
3M
AX 4
Low
NO
x TW
- 1/
230V
/50-
60Hz
22,5
47,4
1,9
4TC
3142
722
MO
DEL
OU
TPU
T [k
W]
FLO
W R
ATE
[kg/
h]BL
AST
TUBE
CODE
MIN
MAX
MIN
MAX
MAX
1 T
W -
1/23
0V/5
0-60
Hz17
,641
,41,
53,
5TC
3142
709
TL31
4271
0
MAX
4 T
W -
1/23
0V/5
0-60
Hz20
591,
75
TC31
4271
4TL
3142
715
MAX
8 T
W -
1/23
0V/5
0-60
Hz47
105
48,
9TC
3142
716
TL31
4271
7
MAX
12
TW -
1/23
0V/5
0-60
Hz60
130
5,1
11TC
3142
718
TL31
4271
9
MAX
15
TW -
1/23
0V/5
0Hz
73,4
190
6,2
16TC
3142
729
TL31
4273
0
MAX
20
TW -
1/23
0V/5
0Hz
86,4
237
7,3
20TC
3142
731
TL31
4273
2
MAX
30
TW -
1/23
0V/5
0Hz
110
319
9,3
27TC
3142
733
TL31
4273
4
MO
DEL
OU
TPU
T [k
W]
FLO
W R
ATE
[kg/
h]BL
AST
TUBE
CODE
MIN
MAX
MIN
MAX
MAX
1 R
TW
- 1/
230V
/50-
60Hz
2039
1,5
3,5
TC31
4271
1TL
3142
712
MAX
4 R
TW
- 1/
230V
/50-
60Hz
2059
1,7
5TC
3142
720
TL31
4272
1
One
stag
e Lo
w N
Ox
class
3 (N
Ox
<120
mg/
kWh)
- B1
0
One
stag
e cla
ss 2
(NO
x <1
85 m
g/kW
h) -
B10
One
stag
e w
ith p
re-h
eate
r ver
sions
(NO
x <1
85 m
g/kW
h) -
B10
MO
DEL
OU
TPU
T [k
W]
FLO
W R
ATE
[kg/
h]BL
AST
TUBE
CODE
MIN
MAX
MIN
MAX
MAX
P 3
5 AB
TW
- 1/
230V
/50H
z16
642
714
36TC
3140
420
TL31
4042
1
MAX
P 4
5 AB
TW
- 3/
230-
400V
/50H
z20
254
617
46TC
3140
933
TL31
4131
4
Tw
o st
ages
clas
s 2 (N
Ox
<185
mg/
kWh)
- B1
0
MAX
www.ecoflam-burners.com20
Tw
o st
ages
hyd
raul
ic sy
stem
clas
s 2 (N
Ox
<185
mg/
kWh)
LIGHT
OIL
BURN
ERS
MO
DEL
OU
TPU
T [k
W]
FLO
W R
ATE
[kg/
h]BL
AST
TUBE
CODE
MIN
MAX
MIN
MAX
MAX
4 H
T TW
- 1/
230V
/50-
60Hz
2059
1,7
5TC
3142
724
TL31
4272
3
MAX
8 H
T TW
- 1/
230V
/50-
60Hz
4710
54
8,9
TC31
4272
6TL
3142
725
MAX
12
HT T
W -
1/23
0V/5
0-60
Hz60
130
5,1
11TC
3142
728
TL31
4272
7
MAX
15
HT T
W -
1/23
0V/5
0Hz
73,4
190
6,2
16TC
3142
735
TL31
4273
6
MAX
20
D HT
TW
- 1/
230V
/50H
z86
,423
77,
320
TC31
4273
7TL
3142
738
MAX
30
D HT
TW
- 1/
230V
/50H
z11
031
99,
327
TC31
4273
9TL
3142
740
MAX
P 3
5 AB
HS
D HT
TW
- 1/
230V
/50H
z16
642
714
36TC
on re
ques
tTL
on re
ques
t
MAX
P 4
5 AB
HS
D HT
TW
- 3/
230-
400V
/50H
z20
254
617
46TC
on re
ques
tTL
on re
ques
t
MO
DEL
OU
TPU
T [k
W]
FLO
W R
ATE
[kg/
h]BL
AST
TUBE
CODE
MIN
MAX
MIN
MAX
MAX
P 1
2 AB
HS
- 1/2
30V/
50-6
0Hz
6013
05,
111
TC31
2409
4TL
3124
095
MAX
P 1
5 AB
HS
- 1/2
30V/
50Hz
7719
06,
516
TC31
2270
8TL
3122
709
MAX
P 2
5 AB
HS
- 1/2
30V/
50Hz
102
300
8,6
25,4
TC31
2271
0TL
3122
274
MAX
P 3
5 AB
HS
TW - 1
/230
V/50
Hz16
642
714
36TC
3140
409
TL31
4041
2
MAX
P 4
5 AB
HS
TW -
3/23
0-40
0V/5
0Hz
202
546
1746
TC31
4041
8TL
3140
419
B10:
oil p
ump
for b
iodi
esel
; D p
ump:
max
visc
osity
5°E
at 2
0°C;
HT:
hig
h te
mpe
ratu
re
One
stag
e cla
ss 2
(NO
x <1
85 m
g/kW
h) -
B10
DESC
RIPT
ION
Diag
nosti
c too
l for
TW
cont
rol b
oxse
e ac
cess
orie
s pag
e
KIT
- AC
CESS
ORI
ES
MAX
www.ecoflam-burners.com 21
LIGHT
OIL
BURN
ERS
MO
DEL
OU
TPU
T [k
W]
FLO
W R
ATE
[kg/
h]SI
LEN
CER
BLAS
T TU
BECO
DEM
INM
AXM
INM
AX
MAI
OR
P 60
AB
HS -
3/23
0-40
0V/5
0Hz
415
710
3560
OPT
TC31
4015
1TL
3140
152
MAI
OR
P 60
AB
HS D
- 3/
230-
400V
/50H
z41
571
035
60O
PTTC
3141
572
TL31
4157
1
MAI
OR
P 80
AB
HS -
3/23
0-40
0V/5
0Hz
474
949
4080
OPT
TC31
2106
3TL
3121
064
MAI
OR
P 12
0 AB
HS -
3/2
30-4
00V/
50Hz
830
1423
7012
0O
PTTC
3121
065
TL31
2106
6
MAI
OR
P 15
0.1
AB H
S - 3
/230
-400
V/50
Hz59
217
8050
150
OPT
TC31
2106
7TL
3121
068
MAI
OR
P 20
0.1
AB H
S - 3
/230
-400
V/50
Hz71
023
7260
200
OPT
TC31
2106
9TL
3121
070
MAI
OR
P 30
0.1
AB H
S - 3
/400
V/50
Hz10
0030
0085
250
OPT
TC31
4374
3TL
3143
744
MAI
OR
P 40
0.1
AB H
S Z3
- 3/
400V
/50H
z13
0039
0011
035
0O
PTTC
3143
745
TL31
4374
6
MO
DEL
OU
TPU
T [k
W]
FLO
W R
ATE
[kg/
h]SI
LEN
CER
BLAS
T TU
BECO
DEM
INM
AXM
INM
AX
MAI
OR
P 60
AB
- 3/2
30-4
00V/
50Hz
415
710
3560
OPT
TC31
2101
6TL
3122
265
MAI
OR
P 80
AB
- 3/2
30-4
00V/
50Hz
474
949
4080
OPT
TC31
2101
8TL
3122
266
MAI
OR
P 12
0 AB
- 3/
230-
400V
/50H
z83
014
2370
120
OPT
TC31
2102
0TL
3122
269
MAI
OR
P 15
0.1
AB -
3/23
0-40
0V/5
0Hz
592
1780
5015
0O
PTTC
3121
022
TL31
2102
1
MAI
OR
P 20
0.1
AB -
3/23
0-40
0V/5
0Hz
710
2372
6020
0O
PTTC
3121
024
TL31
2102
3
MAI
OR
P 30
0.1
AB -
3/40
0V/5
0Hz
1000
3000
8525
0O
PTTC
3143
731
TL31
4374
2
MAI
OR
P 40
0.1
AB Z
3 - 3
/400
V/50
Hz13
0039
0011
035
0O
PTTC
3143
733
TL31
4373
2
Tw
o st
ages
hyd
raul
ic sy
stem
Tw
o st
ages
MAI
OR
www.ecoflam-burners.com22
MO
DEL
OU
TPU
T [k
W]
FLO
W R
ATE
[kg/
h]SI
LEN
CER
BLAS
T TU
BECO
DEM
INM
AXM
INM
AX
MAI
OR
P 45
PR
- 3/2
30-4
00V/
50Hz
296
532
2545
OPT
TLon
requ
est
MAI
OR
P 60
PR
- 3/2
30-4
00V/
50Hz
415
710
3560
OPT
TLon
requ
est
MAI
OR
P 80
PR
- 3/2
30-4
00V/
50Hz
474
949
4080
OPT
TLon
requ
est
MAI
OR
P 12
0 PR
- 3/
230-
400V
/50H
z83
014
2370
120
OPT
TLon
requ
est
MAI
OR
P 15
0.1
PR -
3/23
0-40
0V/5
0Hz
592
1780
5015
0O
PTTL
on re
ques
tM
AIO
R P
200.
1 PR
- 3/
230-
400V
/50H
z71
023
7260
200
OPT
TLon
requ
est
MAI
OR
P 30
0.1
PR -
3/40
0V/5
0Hz
1000
3000
8525
0O
PTTC
3143
734
TL31
4373
5
MAI
OR
P 40
0.1
PR -
3/40
0V/5
0Hz
1300
3900
110
350
OPT
TC31
4373
6TL
3143
737
MAI
OR
P 50
0.1
PR -
3/40
0V/5
0Hz
1578
5000
134
422
OPT
TC31
4373
8TL
3143
739
MAI
OR
P 60
0.1
PR -
3/40
0V/5
0Hz
1795
5800
153
490
OPT
TC31
4374
0TL
3143
741
MAI
OR
P 70
0.1
PR -
3/40
0V/5
0Hz
2417
7500
205
634
OPT
TC
on re
ques
tM
AIO
R P
800.
1 PR
- 3/
400V
/50H
z27
5085
0023
471
8O
PTTC
on
requ
est
MAI
OR
P 10
00.1
PR
- 3/4
00V/
50Hz
3300
1050
028
188
7O
PTTC
on
requ
est
MAI
OR
P 12
00.1
PR
- 3/4
00V/
50Hz
4367
1250
037
110
53O
PTTC
on
requ
est
MAI
OR
P 15
00.1
PR
- 3/4
00V/
50Hz
5000
1500
042
212
65O
PTTC
on
requ
est
MAI
OR
P 18
00.1
PR
- 3/4
00V/
50Hz
5700
1700
048
114
33O
PTTC
on
requ
est
DESC
RIPT
ION
Sile
ncer
see
acce
ssor
ies p
age
Mod
ulati
on k
itse
e ac
cess
orie
s pag
ePr
obe
see
acce
ssor
ies p
age
Pum
ping
uni
tse
e ac
cess
orie
s pag
eKi
t Wie
land
plu
gsse
e ac
cess
orie
s pag
e
MAI
OR
- DU
OBL
OCK
AN
D EL
ECTR
ON
IC B
URN
ERS
Tw
o st
age
prog
ress
ive
mec
hani
cal
KIT
- AC
CESS
ORI
ES
Vers
ions
from
2 to
25
MW
are
ava
ilabl
e on
requ
est f
or se
lect
ed o
utpu
t to
mat
ch m
ain
boile
rs a
nd in
dust
ry a
pplic
ation
.
LIGHT
OIL
BURN
ERS
MAI
OR
www.ecoflam-burners.com 23
MAX
FLAM
- M
ax v
isc. 5
0°E
at 5
0°C
OILF
LAM
- M
ax v
isc. 5
0°E
at 5
0°C
HEAV
Y O
IL BU
RNER
S
MAX
FLAM
and
OIL
FLAM
rang
e w
ork
with
hea
vy
oil u
p to
50°
E at
50°
C w
ith O
n/O
ff sw
itch
to e
xclu
de
the
circu
it he
ater
s in
orde
r to
oper
ate
also
with
low
vi
scos
ity h
eavy
oil.
M10
0 co
nfigu
ratio
n fo
r hea
vy o
il up
to 1
00°E
at 5
0°C
is av
aila
ble
on re
ques
t.
OIL
FLAM
mod
els f
rom
300
.1 a
re su
pplie
d w
ith “G
EFRA
N” d
igita
l the
rmo
regu
lato
r int
egra
ted
on th
e fro
nt p
anel
for g
ranti
ng
tem
pera
ture
stab
ility
of fu
el.
Avai
labl
e ve
rsio
n in
clude
s dou
ble
stag
e up
to 3
50 k
g/h
and
from
the
mod
el O
ILFLA
M 3
00.1
in p
rogr
essiv
e op
erati
on th
at ca
n
be tu
rned
in m
odul
ating
with
a P
ID re
gula
tor.
Easy
mai
nten
ance
syst
em is
inte
grat
ed in
to th
e bu
rner
:•
HING
E FL
ANGE
SYS
TEM
fo
r OILF
LAM
80.
1 to
200
.1 a
nd 1
500.
1 to
180
0.1
• SL
IDIN
G BA
R SY
STEM
fo
r MAX
FLAM
10
to 5
0 an
d O
ILFLA
M 3
00.1
to 1
200.
1
OIL
FLAM
mod
els o
ver 7
MW
are
offe
red
on re
ques
t ba
sed
on th
e co
nfigu
ratio
n re
ques
ted
(mec
hani
cal o
r el
ectro
nic)
in o
rder
to b
etter
fit i
nto
the
appl
icatio
n
and
prov
ide
a cu
stom
ised
and
mor
e co
st e
ffecti
ve so
lutio
n.
DUO
BLO
CK a
nd E
LECT
RON
IC ve
rsio
ns a
re a
vaila
ble
on re
ques
t for
sele
cted
out
put t
o m
atch
mai
n bo
ilers
and
indu
stry
app
licati
on.
All h
eavy
oil
burn
ers a
re d
elive
red
with
ele
ctric
al p
re-h
eate
r pre
asse
mbl
edin
to th
e bu
rner
bod
y, in
cludi
ng fi
lter a
nd fl
exib
le h
oses
up
to 6
MW
.
• KI
T W
iela
nd p
lugs
• KI
T m
agne
tic +
selfc
lean
ing
filte
r•
PID
mod
ulati
ng K
IT a
nd p
robe
• Si
lenc
er (s
tarti
ng fr
om p
latfo
rm 2
60)
• M
100
vers
ion
for h
eavy
oil u
p to
100
°E a
t 50°
C•
From
OILF
LAM
300
.1 p
re-h
eate
r can
be
supp
lied
sepa
rate
ly w
ith e
xtra
cost
• Fo
rced
oil p
repa
ratio
n rin
g sy
stem
on
requ
est
KIT
- ACS
(see
ded
icate
d pa
ges)
AVAI
LABL
E CO
NFI
GURA
TIO
NS
ON
REQ
UES
T
All b
urne
rs 2
30-4
00V/
50Hz
are
fact
ory
test
ed a
t 400
V/50
Hz
thre
e-ph
ase.
If m
ain
supp
ly is
thre
e-ph
ase
230V
/50H
z see
in
stru
ction
man
ual f
or a
djus
tmen
ts a
nd m
odifi
catio
ns.
!
www.ecoflam-burners.com24
HEAV
Y O
IL BU
RNER
S
MO
DEL
OU
TPU
T [k
W]
FLO
W R
ATE
[kg/
h]BL
AST
TUBE
CODE
MIN
MAX
MIN
MAX
MAX
FLAM
10
- 1/2
30V/
50Hz
6813
66
12TC
3143
324
TL31
4332
5
MAX
FLAM
20
- 1/2
30V/
50Hz
108
227
9,5
20TC
3143
326
TL31
4332
7
MAX
FLAM
30
- 3/2
30-4
00V/
50Hz
170
340
1530
TC31
4332
8TL
3143
329
MO
DEL
OU
TPU
T [k
W]
FLO
W R
ATE
[kg/
h]BL
AST
TUBE
CODE
MIN
MAX
MIN
MAX
MAX
FLAM
30
AB -
3/23
0-40
0V/5
0Hz
205
410
1836
TC31
4333
0TL
3143
331
MAX
FLAM
50
AB -
3/23
0-40
0V/5
0Hz
205
570
1850
TC31
4333
2TL
3143
333
MO
DEL
OU
TPU
T [k
W]
FLO
W R
ATE
[kg/
h]SI
LEN
CER
BLAS
T TU
BECO
DEM
INM
AXM
INM
AX
OIL
FLAM
80.
1 AB
- 3/
230-
400V
/50H
z46
493
041
82O
PTTC
3142
604
TL31
4260
5
OIL
FLAM
120
.1 A
B - 3
/230
-400
V/50
Hz
682
1395
6012
2O
PTTC
3142
606
TL31
4260
7
OIL
FLAM
170
.1 A
B - 3
/230
-400
V/50
Hz
682
1700
6014
8O
PTTC
3142
608
TL31
4260
9
OIL
FLAM
200
.1 A
B - 3
/230
-400
V/50
Hz
682
2093
6018
4O
PTTC
3142
610
TL31
4261
1
OIL
FLAM
300
.1 A
B - 3
/400
V/50
Hz10
0030
0088
,526
4O
PTTC
3143
753
TL31
4375
4
OIL
FLAM
400
.1 A
B Z3
- 3/
400V
/50H
z13
0039
0011
534
3O
PTTC
3143
755
TL31
4375
6
MAX
FLAM
OILF
LAM
One
stag
e - 5
0°E
fuel
visc
osity
at 5
0°C
Tw
o st
ages
- 50
°E fu
el v
iscos
ity a
t 50°
C
Tw
o st
ages
- 50
°E fu
el v
iscos
ity a
t 50°
C
www.ecoflam-burners.com 25
MO
DEL
OU
TPU
T [k
W]
FLO
W R
ATE
[kg/
h]SI
LEN
CER
BLAS
T TU
BECO
DEM
INM
AXM
INM
AX
OIL
FLAM
80.
1 PR
- 3/
230-
400V
/50H
z46
493
041
82O
PTTL
on re
ques
tO
ILFL
AM 1
20.1
PR
- 3/2
30-4
00V/
50Hz
682
1395
6012
2O
PTTL
on re
ques
tO
ILFL
AM 1
70.1
PR
- 3/2
30-4
00V/
50Hz
682
1700
6014
8O
PTTL
on re
ques
tO
ILFL
AM 2
00.1
PR
- 3/2
30-4
00V/
50Hz
682
2093
6018
4O
PTTL
on re
ques
t
OIL
FLAM
300
.1 P
R - 3
/400
V/50
Hz10
0030
0088
,526
4O
PTTC
3143
757
TL31
4375
8
OIL
FLAM
400
.1 P
R - 3
/400
V/50
Hz13
0039
0011
534
3O
PTTC
3143
759
TL31
4376
0
OIL
FLAM
500
.1 P
R - 3
/400
V/50
Hz15
7850
0014
044
0O
PTTC
3143
761
TL31
4376
2
OIL
FLAM
600
.1 P
R - 3
/400
V/50
Hz17
9558
0015
951
0O
PTTC
3143
763
TL31
4376
4O
ILFL
AM 7
00.1
PR
- 3/4
00V/
50Hz
2417
7500
214
660
OPT
TCon
requ
est
OIL
FLAM
800
.1 P
R - 3
/400
V/50
Hz27
5085
0024
374
8O
PTTC
on re
ques
tO
ILFL
AM 1
000.
1 PR
- 3/
400V
/50H
z33
0010
500
292
924
OPT
TCon
requ
est
OIL
FLAM
120
0.1
PR -
3/40
0V/5
0Hz
4367
1250
038
610
97O
PTTC
on re
ques
tO
ILFL
AM 1
500.
1 PR
- 3/
400V
/50H
z50
0015
000
440
1319
OPT
TCon
requ
est
OIL
FLAM
180
0.1
PR -
3/40
0V/5
0Hz
5700
1700
050
114
95O
PTTC
on re
ques
t
DESC
RIPT
ION
Sile
ncer
see
acce
ssor
ies p
age
Mod
ulati
on k
itse
e ac
cess
orie
s pag
ePr
obe
see
acce
ssor
ies p
age
Heati
ng a
nd p
umpi
ng u
nit
see
acce
ssor
ies p
age
Mag
netic
+ se
lf cle
anin
g fil
ter
see
acce
ssor
ies p
age
Tw
o st
age
prog
ress
ive
mec
hani
cal -
50°
E fu
el v
iscos
ity a
t 50°
C
KIT
- AC
CESS
ORI
ES
OIL
FLAM
- DU
OBL
OCK
AN
D EL
ECTR
ON
IC B
URN
ERS
Vers
ions
from
2 to
25
MW
are
ava
ilabl
e on
requ
est f
or se
lect
ed o
utpu
t to
mat
ch m
ain
boile
rs a
nd in
dust
ry a
pplic
ation
.
HEAV
Y O
IL BU
RNER
S O
ILFLA
M
www.ecoflam-burners.com26
FORC
ED O
IL PR
EPAR
ATIO
N RI
NG
STAN
DARD
SYS
TEM
CO
MPO
SITI
ON
FO
R LI
GHT
OIL
AN
D HE
AVY
OIL
HEA
TIN
G AN
D PU
MPI
NG
UN
IT1.
Feed
ing
and
filte
ring
syst
em2.
Fue
l hea
ting
syst
em fo
r red
ucin
g oi
l visc
osity
plu
s ser
vice
tank
3. F
orce
d oi
l sup
ply
syst
em “R
ING”
PRE-
HEAT
ER U
NIT
ECO
FLAM
hea
vy o
il bur
ners
are
del
ivere
d w
ith e
lect
rical
pre
-hea
ter a
ssem
bled
into
th
e bu
rner
bod
y or
in a
sepa
rate
skid
.Ad
ditio
nal F
orce
d sy
stem
“OIL
RIN
G”
can
be d
esig
n an
d de
liver
ed a
ssem
bled
on
skid
/fra
me
or o
ffere
d as
sing
le co
mpo
nent
.
ACCE
SSO
RIES
Serv
ice ta
nks +
Pum
ps u
nits
.Q
uota
tion
on re
ques
t dep
endi
ng
on o
utpu
t and
confi
gura
tion.
MAG
NET
IC +
SEL
F CL
EAN
ING
FILT
ERTh
e fil
terin
g sy
stem
ope
ratio
n: th
e fir
st m
agne
tic
filte
r allo
ws t
o se
para
te a
ll fer
rous
impu
rities
co
ntai
ned
in th
e oi
l and
the
seco
nd la
mel
lar
filte
r allo
ws t
he fi
nal fi
ltrati
on o
f all i
mpu
rities
.
hot w
ater
pip
e / s
team
pip
e
hot w
ater
pip
e / s
team
pip
e
Retu
rn
sec�
on
oil p
ipe
oil p
ipe
elec
trica
l hea
�ng
cabl
ein
sula
�on
AA
TT
BB
11
8 7
12 13
55
33
4
6
79
10
1 1
sez.
:A-
AB-
B
2
LEGE
NDA
1. B
urne
rs2.
Ser
vice
tank
3. E
lect
ric h
eate
rs
4. S
afet
y an
d op
erati
on th
erm
osta
t 5.
Leve
l sw
itch
(wor
king
+ sa
fety
)6.
Hea
ting
coil
7. S
elf c
lean
ing
oil fi
lter
8. Lo
ad p
umps
9.
Rin
g pu
mps
10. O
il rin
g co
ntro
l pre
ssur
e de
vice
11. H
eatin
g ca
ble
12. M
ain
heav
y oi
l sto
rage
tank
13. H
eatin
g co
il
All in
stal
latio
ns u
sing
heav
y oi
l bur
ners
hav
e to
be
com
plet
ed w
ith
a FO
RCED
OIL
PRE
PARA
TIO
N R
ING
in o
rder
to g
uara
ntee
oil s
uppl
y to
the
burn
er a
t sui
tabl
e te
mpe
ratu
re a
nd p
ress
ure
(tem
pera
ture
+/
- 80°
C, p
ress
ure
3 ba
r).
For h
eavy
oil w
ith m
ore
than
50°
E at
50°
C EC
OFL
AM re
com
men
ds
to d
ecre
ase
the
max
imum
out
put o
f 10-
20%
and
wor
k in
ecc
ess o
f ai
r in
orde
r to
gran
t bett
er o
pera
tion
and
redu
ce m
aint
enan
ce.
HEAV
Y O
IL P
REPA
RATI
ON
RIN
G: S
UGG
ESTE
D SC
HEM
E
HEAV
Y O
IL
WAR
NIN
GS!
www.ecoflam-burners.com 27
GAS
BURN
ERS
MAX
GAS
- Low
NO
x cla
ss 3
(<80
mg/
kWh)
MAX
GAS
rang
e is
avai
labl
e in
the
follo
win
g ve
rsio
ns a
nd is
del
ivere
d in
a m
odul
ar sy
stem
of b
oxes
:•
P: 1
stag
e so
ft st
art
• PA
B: 2
stag
es•
PR: 2
stag
e pr
ogre
ssive
mec
hani
cal
BBCH
: Bur
ner B
ody
with
Com
busti
on H
ead
→ T
C sh
ort h
ead
and
TL lo
ng h
ead
GT: G
as tr
ain
sepa
rate
→ E
N676
or E
xpor
t con
figur
ation
KIT
& A
CS: k
its a
nd a
cces
sorie
s acc
ordi
ng to
loca
l rul
es in
stal
latio
n
All M
AX G
AS a
re d
elive
red
for n
atur
al g
as a
nd ca
n op
erat
e w
ith LP
G by
chan
ging
the
nozz
le w
ith a
kit.
MAX
GAS
two
stag
es a
re co
mpl
ete
with
two
stag
es M
ultiB
loc v
alve
s M
BZRD
LE fo
r the
mod
els 1
20-2
50 w
here
mod
els 3
50-5
00 o
pera
te in
tw
o st
age
with
butt
erfly
valve
. Pr
ogre
ssive
vers
ion
are
avai
lble
for m
odel
s MAX
GAS
350
-500
and
ca
n be
tran
sform
ed in
to m
odul
ating
with
the
PID
KITM
D-RW
F50.
EN67
6 co
nfigu
ratio
n:
• Ga
sMul
tiBlo
c Dun
gs: c
ompa
ct d
oubl
e so
leno
id va
lve w
ith in
tegr
ated
filte
r, re
gula
tor a
nd
min
pre
ssur
e sw
itch;
• do
uble
sole
noid
valve
s VCS
Kro
msc
hröd
er: d
oubl
e so
leno
id va
lves i
nclu
ding
min
gas
pre
s-su
re sw
itch
+ se
para
te g
as g
over
nor a
nd fi
lter F
GDR.
EXPO
RT co
nfigu
ratio
n (o
ther
add
ition
al o
ption
s to
be a
dded
by
inst
alle
r in
com
plia
nce
with
lo
cal s
afet
y re
gula
tions
):•
doub
le so
leno
id va
lves V
CS K
rom
schr
öder
: dou
ble
sole
noid
valve
s inc
ludi
ng m
in g
as p
ress
ure
switc
h;•
GasM
ultiB
loc D
ungs
GB-
LE 0
55 C
lass
B: c
ompa
ct d
oubl
e so
leno
id va
lve w
ith in
tegr
ated
filte
r, re
gula
tor a
nd m
in p
ress
ure
switc
h av
aila
ble
for M
AX G
AS 4
0-12
0;•
singl
e so
leno
id va
lve B
rahm
a E6
G*SR
P a
nd E
G12*
L for
MAX
GAS
40-
120
com
plet
e w
ith m
in g
as p
ress
ure
switc
h;•
singl
e so
leno
id va
lve K
rom
schr
öder
VAS
125
and
VAS2
40 fo
r MAX
GAS
170
-250
com
plet
e w
ith m
in g
as p
ress
ure
switc
h.
Gas t
rain
mat
chin
g ta
ble
and
pres
sure
dro
p di
agra
ms f
or n
atur
al g
as/L
PG a
re a
vaila
ble
in th
e ga
s tra
in
tech
nica
l doc
umen
tatio
n.
• LP
G KI
T •
KIT
Wie
land
plu
gs•
PID
mod
ulati
ng K
IT a
nd p
robe
• An
tivib
ratio
n co
uplin
g an
d ba
ll val
ve
• CV
: Con
tinuo
us ve
ntila
tion
vers
ion
• HT
: Hig
h Te
mpe
ratu
re ve
rsio
n•
OEM
and
spec
ial a
pplic
ation
vers
ion
only
on
requ
est
KIT
- ACS
(see
ded
icate
d pa
ges)
AVAI
LABL
E CO
NFI
GURA
TIO
NS
ON
REQ
UES
T
All b
urne
rs 2
30-4
00V/
50Hz
are
fact
ory
test
ed a
t 400
V/50
Hz
thre
e-ph
ase.
If m
ain
supp
ly is
thre
e-ph
ase
230V
/50H
z see
in
stru
ction
man
ual f
or a
djus
tmen
ts a
nd m
odifi
catio
ns.
!
www.ecoflam-burners.com28
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
PRES
SURE
[mba
r]G
AS T
RAIN
GAS
GO
VERN
OR
AN
D FI
LTER
MIN
MAX
BLAS
T TU
BECO
DEM
INM
AXCO
DETY
PEØ
MAX
GAS
40
P TW
1/23
0V/5
0-60
Hz17
48TC
3142
741
965
3141
885
MBC
65
DLE
1/2"
incl
uded
920
031
2394
4M
B-DL
E 40
3
TL31
4274
29
6531
4188
5M
BC 6
5 DL
E1/
2"in
clud
ed9
200
3123
944
MB-
DLE
403
MAX
GAS
70
P TW
1/23
0V/5
0-60
Hz34
70
TC31
4274
3
1036
031
2356
0M
B-DL
E 40
53/
4"in
clud
ed11
360
3141
886
MBC
120
DLE
1665
3141
885
MBC
65
DLE
1/2"
1820
031
2394
4M
B-DL
E 40
3
TL31
4274
4
1036
031
2356
0M
B-DL
E 40
53/
4"in
clud
ed11
360
3141
886
MBC
120
DLE
1665
3141
885
MBC
65
DLE
1/2"
1820
031
2394
4M
B-DL
E 40
3
MAX
GAS
105
P T
W1/
230V
/50-
60Hz
4910
8
TC31
4274
5
1636
031
2356
0M
B-DL
E 40
53/
4"in
clud
ed18
360
3141
886
MBC
120
DLE
3465
3141
885
MBC
65
DLE
1/2"
3620
031
2394
4M
B-DL
E 40
3
TL31
4274
6
1636
031
2356
0M
B-DL
E 40
53/
4"in
clud
ed18
360
3141
886
MBC
120
DLE
3465
3141
885
MBC
65
DLE
1/2"
3620
031
2394
4M
B-DL
E 40
3
MAX
GAS
120
P T
W1/
230V
/50-
60Hz
4912
0
TC31
4274
7
1636
031
2356
0M
B-DL
E 40
53/
4"in
clud
ed18
360
3141
886
MBC
120
DLE
3465
3141
885
MBC
65
DLE
1/2"
3620
031
2394
4M
B-DL
E 40
3
TL31
4274
8
1636
031
2356
0M
B-DL
E 40
53/
4"in
clud
ed18
360
3141
886
MBC
120
DLE
3465
3141
885
MBC
65
DLE
1/2"
3620
031
2394
4M
B-DL
E 40
3
GAS
BURN
ERS
DESI
GN
ATIO
NDE
SCRI
PTIO
NTY
PE O
F BU
RNER
ØCO
DEGT
-D1-
GBLE
055-
RP15
-MAX
GAS4
0-12
0M
ultiB
loc
clas
s B -
EN67
6 up
to 7
0 kW
40-1
201/
2"31
4202
7GT
-H1-
E6GS
RP-R
P15-
MAX
GAS4
0-12
0sin
gle
sole
noid
val
ve w
ith m
in g
as p
ress
ure
switc
h40
-120
1/2"
3141
888
GT-H
1-EG
12L-
RP15
-MAX
GAS4
0-12
0sin
gle
sole
noid
val
ve w
ith m
in g
as p
ress
ure
switc
h40
-120
1/2"
3141
887
GT-K
1-VA
S125
-RP2
5-M
AXGA
S170
-250
singl
e so
leno
id v
alve
with
min
gas
pre
ssur
e sw
itch
170-
250
1"31
4281
5GT
-K1-
VAS2
40-R
P40-
MAX
GAS1
70-2
50sin
gle
sole
noid
val
ve w
ith m
in g
as p
ress
ure
switc
h17
0-25
01"
1/2
3142
816
MAX
GAS
One
stag
e Lo
w N
Ox
class
3 (N
Ox
<80
mg/
kWh)
GAS
TRA
IN -
Expo
rt co
nfigu
ratio
n
www.ecoflam-burners.com 29
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
PRES
SURE
[MBA
R]G
AS T
RAIN
GAS
GO
VERN
OR
+ FI
LTER
MIN
MAX
BLAS
T TU
BECO
DEM
INM
AXCO
DETY
PEØ
KIT
ADAP
TOR
MAX
GAS
170
P T
W1/
230V
/50H
z55
175
TC31
4274
913
360
3123
947
MB-
DLE
410
1"in
clud
ed17
3123
525
MB-
DLE
407
3/4"
2631
2356
0M
B-DL
E 40
53/
4"31
2230
0
TL31
4275
013
360
3123
947
MB-
DLE
410
1"in
clud
ed17
3123
525
MB-
DLE
407
3/4"
2631
2356
0M
B-DL
E 40
53/
4"31
2230
0
MAX
GAS
250
P T
W1/
230V
/50H
z55
240
TC31
4275
1
15
360
3141
899
MB-
DLE
412
1"1/
4in
clud
ed17
3123
947
MB-
DLE
410
1"26
3123
525
MB-
DLE
407
3/4"
4031
2356
0M
B-DL
E 40
53/
4"31
2230
0
TL31
4275
2
15
360
3141
899
MB-
DLE
412
1"1/
4in
clud
ed17
3123
947
MB-
DLE
410
1"26
3123
525
MB-
DLE
407
3/4"
4031
2356
0M
B-DL
E 40
53/
4"31
2230
0
MAX
GAS
350
P T
W1/
230V
/50H
z10
035
0
TC31
4328
3
17
360
3142
296
MB-
DLE
415
350/
500
1"1/
2
incl
uded
2031
4229
5M
B-DL
E 41
2 35
0/50
01"
1/4
3731
4266
5M
B-DL
E 41
0 35
0/50
01"
6031
4239
2M
B-DL
E 40
7 35
0/50
03/
4"
TL31
4328
4
17
360
3142
296
MB-
DLE
415
350/
500
1"1/
2
incl
uded
2031
4229
5M
B-DL
E 41
2 35
0/50
01"
1/4
3731
4266
5M
B-DL
E 41
0 35
0/50
01"
6031
4239
2M
B-DL
E 40
7 35
0/50
03/
4"
MAX
GAS
500
P T
W3/
230-
400V
/50H
z12
050
0
TC31
4328
5
20
360
3142
296
MB-
DLE
415
350/
500
1"1/
2
incl
uded
3531
4229
5M
B-DL
E 41
2 35
0/50
01"
1/4
5531
4266
5M
B-DL
E 41
0 35
0/50
01"
9031
4239
2M
B-DL
E 40
7 35
0/50
03/
4"
TL31
4328
6
20
360
3142
296
MB-
DLE
415
350/
500
1"1/
2
incl
uded
3531
4229
5M
B-DL
E 41
2 35
0/50
01"
1/4
5531
4266
5M
B-DL
E 41
0 35
0/50
01"
9031
4239
2M
B-DL
E 40
7 35
0/50
03/
4"
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
PRES
SURE
[mba
r]G
AS T
RAIN
GAS
GO
VERN
OR
AND
FILT
ERM
INM
AXBL
AST
TUBE
CODE
MIN
MAX
CODE
TYPE
ØCO
DETY
PEM
AX G
AS 1
70 P
TW
1/23
0V/5
0Hz
5517
5TC
3142
749
2050
031
4190
6VC
S-12
5 1"
3142
521
FGDR
1"
TL31
4275
020
500
3141
906
VCS-
125
1"31
4252
1FG
DR 1
"
MAX
GAS
250
P T
W1/
230V
/50H
z55
240
TC31
4275
115
500
3142
251
VCS-
240
1"1/
231
4252
3FG
DR 1
"1/2
3431
4190
6VC
S-12
5 1"
3142
521
FGDR
1"
TL31
4275
215
500
3142
251
VCS-
240
1"1/
231
4252
3FG
DR 1
"1/2
3431
4190
6VC
S-12
5 1"
3142
521
FGDR
1"
MAX
GAS
350
P T
W1/
230V
/50H
z10
035
0TC
3143
283
1850
031
4237
5VC
S-24
0 35
0/50
01"
1/2
3142
523
FGDR
1"1
/254
3142
374
VCS-
125
350/
500
1"31
4252
1FG
DR 1
"
TL31
4328
418
500
3142
375
VCS-
240
350/
500
1"1/
231
4252
3FG
DR 1
"1/2
5431
4237
4VC
S-12
5 35
0/50
01"
3142
521
FGDR
1"
MAX
GAS
500
P T
W3/
230-
400V
/50H
z12
050
0TC
3143
285
2450
031
4237
5VC
S-24
0 35
0/50
01"
1/2
3142
523
FGDR
1"1
/298
3142
374
VCS-
125
350/
500
1"31
4252
1FG
DR 1
"
TL31
4328
624
500
3142
375
VCS-
240
350/
500
1"1/
231
4252
3FG
DR 1
"1/2
9831
4237
4VC
S-12
5 35
0/50
01"
3142
521
FGDR
1"
One
stag
e Lo
w N
Ox
class
3 (N
Ox
<80
mg/
kWh)
- VC
S ga
s tra
in v
ersio
ns -
1/23
0/50
-60H
z
www.ecoflam-burners.com30
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
PRES
SURE
[mba
r]G
AS T
RAIN
GAS
GO
VERN
OR
AND
FILT
ERM
INM
AXBL
AST
TUBE
CODE
MIN
MAX
CODE
TYPE
ØKI
T AD
APTO
R
MAX
GAS
120
PAB
1/23
0V/5
0-60
Hz40
120
TC
3123
954
1636
031
2396
0M
B-ZR
DLE
405
3/4"
incl
uded
TL31
2395
516
360
3123
960
MB-
ZRDL
E 40
53/
4"in
clud
ed
MAX
GAS
170
PAB
TW
1/23
0V/5
0Hz
5517
5
TC31
4278
2
13
360
3123
962
MB-
ZRDL
E 41
01"
incl
uded
1731
2396
1M
B-ZR
DLE
407
3/4"
2631
2396
0M
B-ZR
DLE
405
3/4"
3122
300
TL31
4278
3
13
360
3123
962
MB-
ZRDL
E 41
01"
incl
uded
1731
2396
1M
B-ZR
DLE
407
3/4"
2631
2396
0M
B-ZR
DLE
405
3/4"
3122
300
MAX
GAS
250
PAB
TW
1/23
0V/5
0Hz
5524
0
TC31
4278
4
15
360
3141
901
MB-
ZRDL
E 41
21"
1/4
incl
uded
1731
2396
2M
B-ZR
DLE
410
1"
2631
2396
1M
B-ZR
DLE
407
3/4"
4031
2396
0M
B-ZR
DLE
405
3/4"
3122
300
TL31
4278
5
15
360
3141
901
MB-
ZRDL
E 41
21"
1/4
incl
uded
1731
2396
2M
B-ZR
DLE
410
1"
2631
2396
1M
B-ZR
DLE
407
3/4"
4031
2396
0M
B-ZR
DLE
405
3/4"
3122
300
MAX
GAS
350
PAB
TW
1/23
0V/5
0Hz
100
350
TC31
4328
7
17
360
3142
296
MB-
DLE
415
350/
500
1"1/
2
incl
uded
2031
4229
5M
B-DL
E 41
2 35
0/50
01"
1/4
3731
4266
5M
B-DL
E 41
0 35
0/50
01"
6031
4239
2M
B-DL
E 40
7 35
0/50
03/
4"
TL31
4328
8
17
360
3142
296
MB-
DLE
415
350/
500
1"1/
2
incl
uded
2031
4229
5M
B-DL
E 41
2 35
0/50
01"
1/4
3731
4266
5M
B-DL
E 41
0 35
0/50
01"
6031
4239
2M
B-DL
E 40
7 35
0/50
03/
4"
MAX
GAS
500
PAB
TW
3/23
0-40
0V/5
0Hz
120
500
TC31
4328
9
20
360
3142
296
MB-
DLE
415
350/
500
1"1/
2
incl
uded
3531
4229
5M
B-DL
E 41
2 35
0/50
01"
1/4
5531
4266
5M
B-DL
E 41
0 35
0/50
01"
9031
4239
2M
B-DL
E 40
7 35
0/50
03/
4"
TL31
4329
0
20
360
3142
296
MB-
DLE
415
350/
500
1"1/
2
incl
uded
3531
4229
5M
B-DL
E 41
2 35
0/50
01"
1/4
5531
4266
5M
B-DL
E 41
0 35
0/50
01"
9031
4239
2M
B-DL
E 40
7 35
0/50
03/
4"
Tw
o st
ages
Low
NO
x cla
ss 3
(NO
x <8
0 m
g/kW
h)
www.ecoflam-burners.com 31
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
PRES
SURE
[mba
r]G
AS T
RAIN
GAS
GO
VERN
OR
AND
FILT
ERM
INM
AXBL
AST
TUBE
CODE
MIN
MAX
CODE
TYPE
ØCO
DETY
PE
MAX
GAS
350
PAB
TW
1/23
0V/5
0Hz
100
350
TC31
4328
718
500
3142
375
VCS-
240
350/
500
1"1/
231
4252
3FG
DR 1
"1/2
5431
4237
4VC
S-12
5 35
0/50
01"
3142
521
FGDR
1"
TL31
4328
818
500
3142
375
VCS-
240
350/
500
1"1/
231
4252
3FG
DR 1
"1/2
5431
4237
4VC
S-12
5 35
0/50
01"
3142
521
FGDR
1"
MAX
GAS
500
PAB
TW
3/23
0-40
0V/5
0Hz
120
500
TC31
4328
914
500
3142
376
VCS-
350
350/
500
2"31
4252
4FG
DR 2
"18
3142
375
VCS-
240
350/
500
1"1/
231
4252
3FG
DR 1
"1/2
5431
4237
4VC
S-12
5 35
0/50
01"
3142
521
FGDR
1"
TL31
4329
014
500
3142
376
VCS-
350
350/
500
2"31
4252
4FG
DR 2
"18
3142
375
VCS-
240
350/
500
1"1/
231
4252
3FG
DR 1
"1/2
5431
4237
4VC
S-12
5 35
0/50
01"
3142
521
FGDR
1"
Tw
o st
ages
Low
NO
x cla
ss 3
(NO
x <8
0 m
g/kW
h) -
VCS
gas t
rain
ver
sions
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
PRES
SURE
[mba
r]G
AS T
RAIN
GAS
GO
VERN
OR
AND
FILT
ERM
INM
AXBL
AST
TUBE
CODE
MIN
MAX
CODE
TYPE
Ø
MAX
GAS
350
PR
TW1/
230V
/50H
z10
035
0
TC31
4004
7
17
360
3142
296
MB-
DLE
415
350/
500
1"1/
2
incl
uded
2031
4229
5M
B-DL
E 41
2 35
0/50
01"
1/4
3731
4266
5M
B-DL
E 41
0 35
0/50
01"
6031
4239
2M
B-DL
E 40
7 35
0/50
03/
4"
TL31
4004
8
17
360
3142
296
MB-
DLE
415
350/
500
1"1/
2
incl
uded
2031
4229
5M
B-DL
E 41
2 35
0/50
01"
1/4
3731
4266
5M
B-DL
E 41
0 35
0/50
01"
6031
4239
2M
B-DL
E 40
7 35
0/50
03/
4"
MAX
GAS
500
PR
TW3/
230-
400V
/50H
z12
050
0
TC31
4004
9
20
360
3142
296
MB-
DLE
415
350/
500
1"1/
2
incl
uded
3531
4229
5M
B-DL
E 41
2 35
0/50
01"
1/4
5531
4266
5M
B-DL
E 41
0 35
0/50
01"
9031
4239
2M
B-DL
E 40
7 35
0/50
03/
4"
TL31
4005
0
20
360
3142
296
MB-
DLE
415
350/
500
1"1/
2
incl
uded
3531
4229
5M
B-DL
E 41
2 35
0/50
01"
1/4
5531
4266
5M
B-DL
E 41
0 35
0/50
01"
9031
4239
2M
B-DL
E 40
7 35
0/50
03/
4"
Tw
o st
age
prog
ress
ive
mec
hani
cal L
ow N
Ox
class
3 (N
Ox
<80
mg/
kWh)
DESC
RIPT
ION
Tigh
tnes
s con
trol
see
acce
ssor
ies p
age
Mod
ulati
on k
itse
e ac
cess
orie
s pag
ePr
obe
see
acce
ssor
ies p
age
LPG
kit
see
acce
ssor
ies p
age
Adap
tor k
it fo
r gas
trai
n se
e ac
cess
orie
s pag
eAd
ditio
nal g
as a
cces
sorie
sse
e ac
cess
orie
s pag
e
KIT
- AC
CESS
ORI
ES
www.ecoflam-burners.com32
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
PRES
SURE
[mba
r]G
AS T
RAIN
LPG
KIT
ADAP
T. K
ITM
INM
AX
BLAS
T TU
BECO
DEM
INM
AXCO
DETY
PEØ
CODE
CODE
MAX
GAS
350
PR
TW1/
230/
50Hz
100
350
TC31
4004
733
360
3142
392
MB-
DLE
407
350/
500
3/4"
3142
431
-TL
3140
048
MAX
GAS
500
PR
TW3/
230-
400/
50Hz
120
500
TC31
4004
952
360
3142
392
MB-
DLE
407
350/
500
3/4"
3142
431
-TL
3140
050
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
PRES
SURE
[mba
r]G
AS T
RAIN
LPG
KIT
ADAP
T. K
ITM
INM
AX
BLAS
T TU
BECO
DEM
INM
AXCO
DETY
PEØ
CODE
CODE
MAX
GAS
120
PAB
1/23
0/50
-60H
z40
120
TC31
2395
415
360
3123
960
MB-
ZRDL
E 40
53/
4"31
2230
1-
TL31
2395
5
MAX
GAS
170
PAB
TW
1/23
0/50
Hz55
175
TC31
4278
223
360
3123
960
MB-
ZRDL
E 40
53/
4"31
2230
231
2230
0TL
3142
783
MAX
GAS
250
PAB
TW
1/23
0/50
Hz55
240
TC31
4278
434
360
3123
960
MB-
ZRDL
E 40
53/
4"31
2230
231
2230
0TL
3142
785
MAX
GAS
350
PAB
TW
1/23
0/50
Hz10
035
0TC
3143
287
3336
031
4239
2M
B-DL
E 40
7 35
0/50
03/
4"31
4243
1-
TL31
4328
8
MAX
GAS
500
PAB
TW
3/23
0-40
0/50
Hz12
050
0TC
3143
289
5236
031
4239
2M
B-DL
E 40
7 35
0/50
03/
4"31
4243
1-
TL31
4329
0
Tw
o st
ages
Low
NO
x cla
ss 3
(NO
x <8
0 m
g/kW
h) -
LPG
vers
ions
Tw
o st
age
prog
ress
ive
mec
hani
cal L
ow N
Ox
class
3 (N
Ox
<80
mg/
kWh)
- LP
G ve
rsio
ns
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
PRES
SURE
[mba
r]G
AS T
RAIN
LPG
KIT
ADAP
T. K
ITM
INM
AX
BLAS
T TU
BECO
DEM
INM
AXCO
DETY
PEØ
CODE
CODE
MAX
GAS
40
P TW
1/23
0V/5
0-60
Hz17
48TC
3142
741
765
3141
885
MBC
65
DLE
1/2"
3122
301
-TL
3142
742
MAX
GAS
70
P TW
1/23
0V/5
0-60
Hz34
70TC
3142
743
1565
3141
885
MBC
65
DLE
1/2"
3122
301
-TL
3142
744
MAX
GAS
105
P T
W1/
230V
/50-
60Hz
4910
8TC
3142
745
2465
3141
885
MBC
65
DLE
1/2"
3122
301
-TL
3142
746
MAX
GAS
120
P T
W1/
230V
/50-
60Hz
4912
0TC
3142
747
2465
3141
885
MBC
65
DLE
1/2"
3122
301
-TL
3142
748
MAX
GAS
170
P T
W1/
230V
/50H
z55
175
TC31
4274
923
360
3123
560
MB-
DLE
405
3/4"
3122
302
3122
300
TL31
4275
0
MAX
GAS
250
P T
W1/
230V
/50H
z55
240
TC31
4275
134
360
3123
560
MB-
DLE
405
3/4"
3122
302
3122
300
TL31
4275
2
MAX
GAS
350
P T
W1/
230V
/50H
z10
035
0TC
3143
283
3336
031
2239
2M
B-DL
E 40
7 35
0/50
03/
4"31
4243
1-
TL31
4328
4
MAX
GAS
500
P T
W3/
230-
400V
/50H
z12
050
0TC
3143
285
5236
031
2239
2M
B-DL
E 40
7 35
0/50
03/
4"31
4243
1-
TL31
4328
6
One
stag
e Lo
w N
Ox
class
3 (N
Ox
<80
mg/
kWh)
- LP
G ve
rsio
ns
www.ecoflam-burners.com 33
GAS
BURN
ERS
BLU
rang
e is
avai
labl
e in
the
follo
win
g ve
rsio
ns a
nd is
del
ivere
d in
a m
odul
ar sy
stem
of b
oxes
:•
PAB:
2 st
ages
• PR
: 2 st
ages
pro
gres
sive
mec
hani
cal
BBCH
: Bur
ner b
ody
with
com
busti
on h
ead
→ T
C sh
ort h
ead
and
TL lo
ng h
ead
GT: G
as tr
ain
sepa
rate
→ E
N676
or E
xpor
t con
figur
ation
GTCP
: Con
necti
on p
ipe
betw
een
burn
er a
nd g
as tr
ain
star
ting
from
mod
el 1
700.
1FG
DR: G
as g
over
nor a
nd fi
lter f
or d
oubl
e so
leno
id va
lves V
CS K
rom
schr
öder
FILT
ER: f
or d
oubl
e ga
s val
ves V
GD S
iem
ens
KITT
C-...
: Tig
htne
ss co
ntro
l kit
to b
e in
clude
d ov
er 1
200
kW a
ccor
ding
to E
N676
KITP
RES-
...: M
axim
um p
ress
ure
switc
hKI
T &
ACS
can
be a
dded
acc
ordi
ng to
loca
l rul
es in
stal
latio
ns
(sile
ncer
, bal
l val
ve, a
ntivi
brati
on co
uplin
g...)
EN67
6 co
nfigu
ratio
n:
• Ga
sMul
tiBlo
c Dun
gs: c
ompa
ct d
oubl
e so
leno
id va
lve w
ith in
tegr
ated
filte
r, re
gula
tor
and
min
pre
ssur
e sw
itch
up to
mod
el B
LU 2
000.
1;•
doub
le so
leno
id va
lves V
CS K
rom
schr
öder
: dou
ble
sole
noid
valve
s inc
ludi
ng
min
imum
gas
pre
ssur
e sw
itch
+ se
para
te g
as g
over
nor a
nd fi
lter F
GDR;
• do
uble
gas
valve
s with
act
uato
rs a
nd re
gula
tor V
GD S
iem
ens§ +
gas
filte
r;•
KITT
C-...
Tig
htne
ss co
ntro
l dev
ice m
ust b
e in
clude
d ov
er 1
200
kW a
ccor
ding
to E
N676
;•
KITP
RES.
.. M
axim
um p
ress
ure
switc
h as
opti
on o
r in
com
plia
nce
with
loca
l saf
ety
regu
latio
ns.
EXPO
RT co
nfigu
ratio
n (o
ther
s add
ition
al o
ption
s to
be a
dded
by
inst
alle
r in
com
plia
nce
with
loca
l saf
ety
regu
latio
ns):
• do
uble
sole
noid
valve
s VCS
Kro
msc
hröd
er: d
oubl
e so
leno
id va
lves i
nclu
ding
min
gas
pre
ssur
e sw
itch;
• do
uble
gas
valve
s with
act
uato
rs a
nd re
gula
tor V
GD S
iem
ens§ .
§ VG
D Si
emen
s: d
efau
lt bl
ank
sprin
g, h
ead
pres
sure
0...
22 m
bar;
fro
m B
LU 3
00.1
chan
ge sp
ring
and
dam
ping
(see
pag
. 53)
.
Gas t
rain
mat
chin
g ta
ble
and
pres
sure
dro
p di
agra
ms f
or n
atur
al g
as/L
PG a
re a
vaila
ble
in th
e ga
s tra
in te
chni
cal d
ocum
enta
tion.
• LP
G KI
T up
to B
lu 2
000.
1•
KIT
Wie
land
plu
gs•
PID
mod
ulati
ng K
IT a
nd p
robe
• An
tivib
ratio
n co
uplin
g an
d ba
ll val
ve•
Sile
ncer
(sta
rting
from
pla
tform
260
)
• CV
: Con
tinuo
us ve
ntila
tion
vers
ion
• O
EM a
nd sp
ecia
l app
licati
on ve
rsio
n on
ly o
n re
ques
t•
KITS
WIR
L: S
wirl
syst
em fo
r flam
e cu
stom
ized
in o
ur
FLEX
SHO
P
KIT
- ACS
(see
ded
icate
d pa
ges)
AVAI
LABL
E CO
NFI
GURA
TIO
NS
ON
REQ
UES
T
BLU
- Lo
w N
Ox c
lass
3 (<
80 m
g/kW
h) a
nd cl
ass 2
(<12
0 m
g/kW
h)
All b
urne
rs 2
30-4
00V/
50Hz
are
fact
ory
test
ed a
t 400
V/50
Hz
thre
e-ph
ase.
If m
ain
supp
ly is
thre
e-ph
ase
230V
/50H
z see
in
stru
ction
man
ual f
or a
djus
tmen
ts a
nd m
odifi
catio
ns.
!
www.ecoflam-burners.com34
GAS
BURN
ERS
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
SILE
NCER
CON
NEC
TIO
N
PIPE
PRES
SURE
[mba
r]G
AS T
RAIN
GAS
GO
VERN
OR
AND
FILT
ERM
INM
AXBL
AST
TUBE
CODE
MIN
MAX
CODE
TYPE
ØCO
DETY
PE
BLU
700
.1 P
AB L
ow N
Ox
3/23
0-40
0/50
Hz27
070
0
TC31
2401
2O
PT-
1550
031
4186
2VC
S 35
02"
3142
524
FGDR
2"
3031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/217
531
4202
4VC
S 12
51"
3142
521
FGDR
1"
TL31
2401
3O
PT-
1550
031
4186
2VC
S 35
02"
3142
524
FGDR
2"
3031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/217
531
4202
4VC
S 12
51"
3142
521
FGDR
1"
BLU
100
0.1
PAB
Low
NO
x3/
230-
400/
50Hz
280
875
TC31
4030
3O
PT-
3050
031
4186
2VC
S 35
02"
3142
524
FGDR
2"
6031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/217
031
4202
4VC
S 12
51"
3142
521
FGDR
1"
TL31
4030
4O
PT-
3050
031
4186
2VC
S 35
02"
3142
524
FGDR
2"
6031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/217
031
4202
4VC
S 12
51"
3142
521
FGDR
1"
BLU
120
0.1
PAB
Low
NO
x3/
230-
400/
50Hz
290
1100
TC31
4030
9O
PT-
2050
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"30
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"65
500
3142
025
VCS
240
1"1/
231
4252
3FG
DR 1
"1/2
TL31
4031
0O
PT-
2050
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"30
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"65
500
3142
025
VCS
240
1"1/
231
4252
3FG
DR 1
"1/2
BLU
150
0.1
PAB
Low
NO
x3/
230-
400/
50Hz
300
1550
TC31
4031
2O
PT
3141
842
3050
031
2411
0VG
D 40
.065
2"1/
231
2411
1Fi
lter 2
"1/2
3142
076
4050
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"
-60
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"13
050
031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/2
TL31
4031
3O
PT
3141
842
3050
031
2411
0VG
D 40
.065
2"1/
231
2411
1Fi
lter 2
"1/2
3142
076
4050
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"
-60
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"13
050
031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/2
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
SILE
NCER
CONN
ECTI
ON
PI
PEPR
ESSU
RE [m
bar]
GAS
TRA
ING
AS G
OVE
RNO
R AN
D FI
LTER
MIN
MAX
BLAS
T TU
BECO
DEM
INM
AXCO
DETY
PEØ
CODE
TYPE
BLU
100
0.1
PAB
3/23
0-40
0/50
Hz24
597
0
TC31
2401
4O
PT-
2550
031
4186
2VC
S 35
02"
3142
524
FGDR
2"
5531
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/216
531
4202
4VC
S 12
51"
3142
523
FGDR
1"1
/2
TL31
2401
5O
PT-
2550
031
4186
2VC
S 35
02"
3142
524
FGDR
2"
5531
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/216
531
4202
4VC
S 12
51"
3142
523
FGDR
1"1
/2
BLU
Tw
o st
ages
Low
NO
x (N
Ox
<80
mg/
kWh)
Tw
o st
ages
www.ecoflam-burners.com 35
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
SILE
NCER
CONN
ECTI
ON
PI
PEPR
ESSU
RE [m
bar]
GAS
TRA
ING
AS G
OVE
RNO
R AN
D FI
LTER
MIN
MAX
BLAS
T TU
BECO
DEM
INM
AXCO
DETY
PEØ
CODE
TYPE
BLU
120
0.1
PAB
3/23
0-40
0/50
Hz26
012
00
TC31
2401
6O
PT-
2550
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"35
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"80
500
3142
025
VCS
240
1"1/
231
4252
3FG
DR 1
"1/2
TL31
2401
7O
PT-
2550
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"35
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"80
500
3142
025
VCS
240
1"1/
231
4252
3FG
DR 1
"1/2
BLU
170
0.1
PAB
3/23
0-40
0/50
Hz34
217
70
TC31
4032
6O
PT
3142
069
2050
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
80
3142
074
4550
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"65
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"15
050
031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/2
TL31
4032
7O
PT
3142
069
2050
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
80
3142
074
4550
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"65
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"15
050
031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/2
BLU
200
0.1
PAB
3/23
0-40
0/50
Hz41
421
50
TC31
4033
0O
PT
3142
069
2350
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
8031
4219
735
500
3124
110
VGD
40.0
652"
1/2
3124
111
Filte
r DN
65
3142
074
6050
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"90
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"22
050
031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/2
TL31
4033
1O
PT
3142
069
2350
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
8031
4219
735
500
3124
110
VGD
40.0
652"
1/2
3124
111
Filte
r DN
65
3142
074
6050
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"90
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"22
050
031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/2
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
SILE
NCER
CONN
ECTI
ON
PI
PEPR
ESSU
RE [m
bar]
GAS
TRA
ING
AS G
OVE
RNO
R AN
D FI
LTER
MIN
MAX
BLAS
T TU
BECO
DEM
INM
AXCO
DETY
PEØ
CODE
TYPE
BLU
700
.1 P
R Lo
w N
Ox
3/23
0-40
0/50
Hz27
070
0
TC31
2403
0O
PT-
1550
031
4186
2VC
S 35
02"
3142
524
FGDR
2"
3031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/217
531
4202
4VC
S 12
51"
3142
521
FGDR
1"
TL31
2388
6O
PT-
1550
031
4186
2VC
S 35
02"
3142
524
FGDR
2"
3031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/217
531
4202
4VC
S 12
51"
3142
521
FGDR
1"
BLU
100
0.1
PR L
ow N
Ox
3/23
0-40
0/50
Hz28
087
5
TC31
4258
7O
PT-
3050
031
4186
2VC
S 35
02"
3142
524
FGDR
2"
6031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/217
031
4202
4VC
S 12
51"
3142
521
FGDR
1"1
/2
TL31
4039
1O
PT-
3050
031
4186
2VC
S 35
02"
3142
524
FGDR
2"
6031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/217
031
4202
4VC
S 12
51"
3142
521
FGDR
1"1
/2
BLU
120
0.1
PR L
ow N
Ox
3/23
0-40
0/50
Hz29
011
00
TC31
4039
6O
PT-
2050
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"30
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"65
500
3142
025
VCS
240
1"1/
231
4252
3FG
DR 1
"1/2
TL31
4039
7O
PT-
2050
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"30
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"65
500
3142
025
VCS
240
1"1/
231
4252
3FG
DR 1
"1/2
Tw
o st
age
prog
ress
ive
mec
hani
cal L
ow N
Ox
class
3 (N
Ox
<80
mg/
kWh)
www.ecoflam-burners.com36
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
SILE
NCER
CONN
ECTI
ON
PI
PEPR
ESSU
RE [m
bar]
GAS
TRA
ING
AS G
OVE
RNO
R AN
D FI
LTER
MIN
MAX
BLAS
T TU
BECO
DEM
INM
AXCO
DETY
PEØ
CODE
TYPE
BLU
150
0.1
PR L
ow N
Ox
3/23
0-40
0/50
Hz30
015
50
TC31
2410
9O
PT
3141
842
3050
031
2411
0VG
D 40
.065
2"1/
231
2411
1Fi
lter 2
"1/2
3142
076
4050
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"
-60
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"13
050
031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/2
TL31
4040
0O
PT
3141
842
3050
031
2411
0VG
D 40
.065
2"1/
231
2411
1Fi
lter 2
"1/2
3142
076
4050
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"
-60
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"13
050
031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/2
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
SILE
NCER
CONN
ECTI
ON
PI
PEPR
ESSU
RE [m
bar]
GAS
TRA
ING
AS G
OVE
RNO
R AN
D FI
LTER
MIN
MAX
BLAS
T TU
BECO
DEM
INM
AXCO
DETY
PEØ
CODE
TYPE
BLU
100
0.1
PR3/
230-
400/
50Hz
245
970
TC31
2403
1O
PT-
2550
031
4186
2VC
S 35
02"
3142
524
FGDR
2"
5531
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/216
531
4202
4VC
S 12
51"
3142
523
FGDR
1"1
/2
TL31
2403
2O
PT-
2550
031
4186
2VC
S 35
02"
3142
524
FGDR
2"
5531
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/216
531
4202
4VC
S 12
51"
3142
523
FGDR
1"1
/2
BLU
120
0.1
PR3/
230-
400/
50Hz
260
1200
TC31
2403
3O
PT-
2550
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"35
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"80
500
3142
025
VCS
240
1"1/
231
4252
3FG
DR 1
"1/2
TL31
2403
4O
PT-
2550
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"35
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"80
500
3142
025
VCS
240
1"1/
231
4252
3FG
DR 1
"1/2
BLU
170
0.1
PR3/
230-
400/
50Hz
342
1770
TC31
4040
1O
PT
3142
069
2050
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
80
3142
074
4550
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"65
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"15
050
031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/2
TL31
4040
2O
PT
3142
069
2050
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
80
3142
074
4550
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"65
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"15
050
031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/2
BLU
200
0.1
PR3/
230-
400/
50Hz
414
2150
TC31
4040
3O
PT
3142
069
2350
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
8031
4219
735
500
3124
110
VGD
40.0
65DN
6531
2411
1Fi
lter D
N65
3142
074
6050
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"90
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"22
050
031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/2
TL31
4040
4O
PT
3142
069
2350
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
8031
4219
735
500
3124
110
VGD
40.0
65DN
6531
2411
1Fi
lter D
N65
3142
074
6050
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"90
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"22
050
031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/2
Tw
o st
age
prog
ress
ive
mec
hani
cal
www.ecoflam-burners.com 37
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
SILE
NCER
CONN
ECTI
ON
PI
PEPR
ESSU
RE [m
bar]
GAS
TRA
ING
AS G
OVE
RNO
R AN
D FI
LTER
MIN
MAX
BLAS
T TU
BECO
DEM
INM
AXCO
DETY
PEØ
BLU
700
.1 P
AB L
ow N
Ox
3/23
0-40
0/50
Hz27
070
0
TC31
2401
2O
PT-
1736
031
4184
7M
B-DL
E 42
02"
incl
uded
2531
4184
6M
B-DL
E 41
51"
1/2
7531
4202
2M
B-DL
E 41
01"
TL31
2401
3O
PT-
1736
031
4184
7M
B-DL
E 42
02"
incl
uded
2531
4184
6M
B-DL
E 41
51"
1/2
7531
4202
2M
B-DL
E 41
01"
BLU
100
0.1
PAB
Low
NO
x3/
230-
400/
50Hz
280
875
TC31
4030
3O
PT-
3536
031
4184
7M
B-DL
E 42
02"
incl
uded
4031
4184
6M
B-DL
E 41
51"
1/2
7531
4184
5M
B-DL
E 41
21"
1/4
TL31
4030
4O
PT-
3536
031
4184
7M
B-DL
E 42
02"
incl
uded
4031
4184
6M
B-DL
E 41
51"
1/2
7531
4184
5M
B-DL
E 41
21"
1/4
BLU
120
0.1
PAB
Low
NO
x3/
230-
400/
50Hz
290
1100
TC31
4030
9O
PT-
3536
031
4184
7M
B-DL
E 42
02"
incl
uded
4531
4184
6M
B-DL
E 41
51"
1/2
8531
4184
5M
B-DL
E 41
21"
1/4
TL31
4031
0O
PT-
3536
031
4184
7M
B-DL
E 42
02"
incl
uded
4531
4184
6M
B-DL
E 41
51"
1/2
8531
4184
5M
B-DL
E 41
21"
1/4
BLU
150
0.1
PAB
Low
NO
x3/
230-
400/
50Hz
300
1550
TC31
4031
2O
PT31
4207
660
360
3141
847
MB-
DLE
420
2"in
clud
ed70
3141
846
MB-
DLE
415
1"1/
2
TL31
4031
3O
PT31
4207
660
360
3141
847
MB-
DLE
420
2"in
clud
ed70
3141
846
MB-
DLE
415
1"1/
2
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
SILE
NCER
CONN
ECTI
ON
PI
PEPR
ESSU
RE [m
bar]
GAS
TRA
ING
AS G
OVE
RNO
R AN
D FI
LTER
MIN
MAX
BLAS
T TU
BECO
DEM
INM
AXCO
DETY
PEØ
BLU
100
0.1
PAB
3/23
0-40
0/50
Hz24
597
0
TC31
2401
4O
PT-
2736
031
4184
7M
B-DL
E 42
02"
incl
uded
3531
4184
6M
B-DL
E 41
51"
1/2
7531
4184
5M
B-DL
E 41
21"
1/4
TL31
2401
5O
PT-
2736
031
4184
7M
B-DL
E 42
02"
incl
uded
3531
4184
6M
B-DL
E 41
51"
1/2
7531
4184
5M
B-DL
E 41
21"
1/4
BLU
120
0.1
PAB
3/23
0-40
0/50
Hz26
012
00
TC31
2401
6O
PT-
4036
031
4184
7M
B-DL
E 42
02"
incl
uded
5031
4184
6M
B-DL
E 41
51"
1/2
100
3141
845
MB-
DLE
412
1"1/
4
TL31
2401
7O
PT-
4036
031
4184
7M
B-DL
E 42
02"
incl
uded
5031
4184
6M
B-DL
E 41
51"
1/2
100
3141
845
MB-
DLE
412
1"1/
4
BLU
170
0.1
PAB
3/23
0-40
0/50
Hz34
217
70TC
3140
326
OPT
3142
074
6036
031
4184
7M
B-DL
E 42
02"
incl
uded
8531
4184
6M
B-DL
E 41
51"
1/2
TL31
4032
7O
PT31
4207
460
360
3141
847
MB-
DLE
420
2"in
clud
ed85
3141
846
MB-
DLE
415
1"1/
2
BLU
200
0.1
PAB
3/23
0-40
0/50
Hz41
421
50TC
3140
330
OPT
3142
074
7536
031
4184
7M
B-DL
E 42
02"
incl
uded
100
3141
846
MB-
DLE
415
1"1/
2
TL31
4033
1O
PT31
4207
475
360
3141
847
MB-
DLE
420
2"in
clud
ed10
031
4184
6M
B-DL
E 41
51"
1/2
Tw
o st
ages
- M
ultiB
loc g
as tr
ain
www.ecoflam-burners.com38
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
SILE
NCER
CONN
ECTI
ON
PI
PEPR
ESSU
RE [m
bar]
GAS
TRA
ING
AS G
OVE
RNO
R AN
D FI
LTER
MIN
MAX
BLAS
T TU
BECO
DEM
INM
AXCO
DETY
PEØ
BLU
100
0.1
PR3/
230-
400/
50Hz
245
970
TC31
2403
1O
PT-
2736
031
4184
7M
B-DL
E 42
02"
incl
uded
3531
4184
6M
B-DL
E 41
51"
1/2
7531
4184
5M
B-DL
E 41
21"
1/4
TL31
2403
2O
PT-
2736
031
4184
7M
B-DL
E 42
02"
incl
uded
3531
4184
6M
B-DL
E 41
51"
1/2
7531
4184
5M
B-DL
E 41
21"
1/4
BLU
120
0.1
PR3/
230-
400/
50Hz
260
1200
TC31
2403
3O
PT-
4036
031
4184
7M
B-DL
E 42
02"
incl
uded
5031
4184
6M
B-DL
E 41
51"
1/2
100
3141
845
MB-
DLE
412
1"1/
4
TL31
2403
4O
PT-
4036
031
4184
7M
B-DL
E 42
02"
incl
uded
5031
4184
6M
B-DL
E 41
51"
1/2
100
3141
845
MB-
DLE
412
1"1/
4
BLU
170
0.1
PR3/
230-
400/
50Hz
342
1770
TC31
4040
1O
PT31
4207
460
360
3141
847
MB-
DLE
420
2"in
clud
ed85
3141
846
MB-
DLE
415
1"1/
2
TL31
4040
2O
PT31
4207
460
360
3141
847
MB-
DLE
420
2"in
clud
ed85
3141
846
MB-
DLE
415
1"1/
2
BLU
200
0.1
PR3/
230-
400/
50Hz
414
2150
TC31
4040
3O
PT31
4207
475
360
3141
847
MB-
DLE
420
2"in
clud
ed10
031
4184
6M
B-DL
E 41
51"
1/2
TL31
4040
4O
PT31
4207
475
360
3141
847
MB-
DLE
420
2"in
clud
ed10
031
4184
6M
B-DL
E 41
51"
1/2
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
SILE
NCER
CONN
ECTI
ON
PI
PEPR
ESSU
RE [m
bar]
GAS
TRA
ING
AS G
OVE
RNO
R AN
D FI
LTER
MIN
MAX
BLAS
T TU
BECO
DEM
INM
AXCO
DETY
PEØ
BLU
700
.1 P
R Lo
w N
Ox
3/23
0-40
0/50
Hz27
070
0
TC31
2403
0O
PT-
1736
031
4184
7M
B-DL
E 42
02"
incl
uded
2531
4184
6M
B-DL
E 41
51"
1/2
7531
4202
2M
B-DL
E 41
01"
TL31
2388
6O
PT-
1736
031
4184
7M
B-DL
E 42
02"
incl
uded
2531
4184
6M
B-DL
E 41
51"
1/2
7531
4202
2M
B-DL
E 41
01"
BLU
100
0.1
PR L
ow N
Ox
3/23
0-40
0/50
Hz28
087
5
TC31
4258
7O
PT-
3536
031
4184
7M
B-DL
E 42
02"
incl
uded
4031
4184
6M
B-DL
E 41
51"
1/2
7531
4184
5M
B-DL
E 41
21"
1/4
TL31
4039
1O
PT-
3536
031
4184
7M
B-DL
E 42
02"
incl
uded
4031
4184
6M
B-DL
E 41
51"
1/2
7531
4184
5M
B -D
LE 4
121"
1/4
BLU
120
0.1
PR L
ow N
Ox
3/23
0-40
0/50
Hz29
011
00
TC31
4039
6O
PT-
3536
031
4184
7M
B-DL
E 42
02"
incl
uded
4531
4184
6M
B-DL
E 41
51"
1/2
8531
4184
5M
B -D
LE 4
121"
1/4
TL31
4039
7O
PT-
3536
031
4184
7M
B-DL
E 42
02"
incl
uded
4531
4184
6M
B-DL
E 41
51"
1/2
8531
4184
5M
B-DL
E 41
21"
1/4
BLU
150
0.1
PR L
ow N
Ox
3/23
0-40
0/50
Hz30
015
50TC
3124
109
OPT
3142
076
6036
031
4184
7M
B-DL
E 42
02"
incl
uded
7031
4184
6M
B-DL
E 41
51"
1/2
TL31
4040
0O
PT31
4207
660
360
3141
847
MB-
DLE
420
2"in
clud
ed70
3141
846
MB-
DLE
415
1"1/
2
Tw
o st
age
prog
ress
ive
mec
hani
cal
www.ecoflam-burners.com 39
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
SILE
NCER
CONN
ECTI
ON
PI
PEPR
ESSU
RE [m
bar]
GAS
TRA
IN (§
)G
AS G
OVE
RNO
R AN
D FI
LTER
MIN
MAX
BLAS
T TU
BECO
DEM
INM
AXCO
DETY
PEØ
CODE
TYPE
BLU
300
0.1
PR3/
400/
50Hz
630
3000
TC31
4175
3O
PT
314
2069
+31
4207
322
500
3141
869
VGD
40.1
00DN
100
3142
205
Filte
r DN
100
3142
069
3550
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
8031
4219
755
500
3124
110
VGD
40.0
65DN
6531
2411
1Fi
lter D
N65
3142
075
100
500
3123
860
VGD
20.5
032"
3121
384
Filte
r 2"
TL31
4175
4O
PT
3142
069+
3142
073
2250
031
4186
9VG
D 40
.100
DN10
031
4220
5Fi
lter D
N10
0
3142
069
3550
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
8031
4219
755
500
3124
110
VGD
40.0
65DN
6531
2411
1Fi
lter D
N65
3142
075
100
500
3123
860
VGD
20.5
032"
3121
384
Filte
r 2"
BLU
400
0.1
PR3/
400/
50Hz
875
3900
TC31
4175
6O
PT
3142
069+
3142
073
3050
031
4186
9VG
D 40
.100
DN10
031
4220
5Fi
lter D
N10
0
3142
069
5050
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
8031
4219
790
500
3124
110
VGD
40.0
65DN
6531
2411
1Fi
lter D
N65
3142
075
170
500
3123
860
VGD
20.5
032"
3121
384
Filte
r 2"
TL31
4175
7O
PT
3142
069+
3142
073
3050
031
4186
9VG
D 40
.100
DN10
031
4220
5Fi
lter D
N10
0
3142
069
5050
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
8031
4219
790
500
3124
110
VGD
40.0
65DN
6531
2411
1Fi
lter D
N65
3142
075
170
500
3123
860
VGD
20.5
032"
3121
384
Filte
r 2"
BLU
500
0.1
PR3/
400/
50Hz
1200
5000
TC31
4175
8O
PT
3142
198
3550
031
4266
6VG
D 40
.125
DN12
531
4220
6Fi
lter D
N12
531
4207
0+31
4207
345
500
3141
869
VGD
40.1
00DN
100
3142
205
Filte
r DN
100
3142
070
7550
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
8031
4207
114
050
031
2411
0VG
D 40
.065
DN65
3124
111
Filte
r DN
6531
4207
525
050
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"
TL31
4175
9O
PT
3142
198
3550
031
4266
6VG
D 40
.125
DN12
531
4220
6Fi
lter D
N12
531
4207
0+31
4207
345
500
3141
869
VGD
40.1
00DN
100
3142
205
Filte
r DN
100
3142
070
7550
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
8031
4207
114
050
031
2411
0VG
D 40
.065
DN65
3124
111
Filte
r DN
6531
4207
525
050
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"
BLU
600
0.1
PR3/
400/
50Hz
1500
5800
TC31
4176
1O
PT
3142
198
5050
031
4266
6VG
D 40
.125
DN12
531
4220
6Fi
lter D
N12
531
4207
0+31
4207
360
500
3141
869
VGD
40.1
00DN
100
3142
205
Filte
r DN
100
3142
070
100
500
3142
026
VGD
40.0
80DN
8031
4208
8Fi
lter D
N80
3142
071
180
500
3124
110
VGD
40.0
65DN
6531
2411
1Fi
lter D
N65
3142
075
340
500
3123
860
VGD
20.5
032"
3121
384
Filte
r 2"
TL31
4176
2O
PT
3142
198
5050
031
4266
6VG
D 40
.125
DN12
531
4220
6Fi
lter D
N12
531
4207
0+31
4207
360
500
3141
869
VGD
40.1
00DN
100
3142
205
Filte
r DN
100
3142
070
100
500
3142
026
VGD
40.0
80DN
8031
4208
8Fi
lter D
N80
3142
071
180
500
3124
110
VGD
40.0
65DN
6531
2411
1Fi
lter D
N65
3142
075
340
500
3123
860
VGD
20.5
032"
3121
384
Filte
r 2"
§ VG
D Si
emen
s: d
efau
lt bl
ank
sprin
g, h
ead
pres
sure
0...
22 m
bar;
from
BLU
300
0.1
chan
ge sp
ring
and
dam
ping
(see
pag
. 53)
Tw
o st
age
prog
ress
ive
mec
hani
cal
!
www.ecoflam-burners.com40
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
SILE
NCER
CONN
ECTI
ON
PI
PEPR
ESSU
RE [m
bar]
GAS
TRA
IN (§
)G
AS G
OVE
RNO
R AN
D FI
LTER
MIN
MAX
BLAS
T TU
BECO
DEM
INM
AXCO
DETY
PEØ
CODE
TYPE
BLU
700
0.1
PR3/
400/
50Hz
1500
7500
TC
3143
747
OPT
3142
422+
3142
425
60
500
3142
666
VGD
40.1
25DN
125
3142
206
Filte
r DN
125
3142
422
7531
4186
9VG
D 40
.100
DN10
031
4220
5Fi
lter D
N10
031
4242
414
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
8031
4242
328
031
2411
0VG
D 40
.065
DN65
3124
111
Filte
r DN
65
BLU
800
0.1
PR3/
400/
50Hz
2000
8500
TC31
4374
8O
PT
3142
422+
3142
425
85
500
3142
666
VGD
40.1
25DN
125
3142
206
Filte
r DN
125
3142
422
110
3141
869
VGD
40.1
00DN
100
3142
205
Filte
r DN
100
3142
424
210
3142
026
VGD
40.0
80DN
8031
4208
8Fi
lter D
N80
3142
423
410
3124
110
VGD
40.0
65DN
6531
2411
1Fi
lter D
N65
BLU
100
00.1
PR
3/40
0/50
Hz25
0010
500
TC31
4374
9O
PT
3142
422+
3142
425
115
500
3142
666
VGD
40.1
25DN
125
3142
206
Filte
r DN
125
3142
422
165
3141
869
VGD
40.1
00DN
100
3142
205
Filte
r DN
100
3142
424
290
3142
026
VGD
40.0
80DN
8031
4208
8Fi
lter D
N80
3142
423
550
3124
110
VGD
40.0
65DN
6531
2411
1Fi
lter D
N65
BLU
120
00.1
PR
3/40
0/50
Hz27
0013
000
TC31
4375
0O
PT
3142
422+
3142
425
175
500
3142
666
VGD
40.1
25DN
125
3142
206
Filte
r DN
125
3142
422
230
3141
869
VGD
40.1
00DN
100
3142
205
Filte
r DN
100
3142
424
420
3142
026
VGD
40.0
80DN
8031
4208
8Fi
lter D
N80
BLU
150
00.1
PR
3/40
0/50
Hz36
9015
000
TC31
4375
1O
PT
3142
422+
3142
425
150
500
3142
666
VGD
40.1
25DN
125
3142
206
Filte
r DN
125
3142
422
230
3141
869
VGD
40.1
00DN
100
3142
205
Filte
r DN
100
3142
424
450
3142
026
VGD
40.0
80DN
8031
4208
8Fi
lter D
N80
BLU
180
00.1
PR
3/40
0/50
Hz40
0017
000
TC31
4375
2O
PT31
4242
2+31
4242
521
050
031
4266
6VG
D 40
.125
DN12
531
4220
6Fi
lter D
N12
5
3142
422
330
3141
869
VGD
40.1
00DN
100
3142
205
Filte
r DN
100
DESC
RIPT
ION
Sile
ncer
see
acce
ssor
ies p
age
Tigh
tnes
s con
trol
see
acce
ssor
ies p
age
Mod
ulati
on k
itse
e ac
cess
orie
s pag
ePr
obe
see
acce
ssor
ies p
age
LPG
kit
see
acce
ssor
ies p
age
Adap
tor k
it fo
r gas
trai
n se
e ac
cess
orie
s pag
eAd
ditio
nal g
as a
cces
sorie
sse
e ac
cess
orie
s pag
e
KIT
- AC
CESS
ORI
ES
BLU
- DU
OBL
OCK
AN
D EL
ECTR
ON
IC B
URN
ERS
Vers
ions
from
2 to
25
MW
are
ava
ilabl
e on
requ
est f
or se
lect
ed o
utpu
t to
mat
ch m
ain
boile
rs a
nd in
dust
ry a
pplic
ation
.
§ VG
D Si
emen
s: d
efau
lt bl
ank
sprin
g, h
ead
pres
sure
0...
22 m
bar;
from
BLU
300
0.1
chan
ge sp
ring
and
dam
ping
(see
pag
. 53)
!
www.ecoflam-burners.com 41
DUAL
FUEL
BUR
NERS
(GAS
/LIG
HT O
IL)
MUL
TICA
LOR
MU
LTIC
ALO
R is
avai
labl
e in
the
follo
win
g ve
rsio
ns a
nd is
del
ivere
d in
a m
odul
ar sy
stem
of b
oxes
:•
AB: 2
stag
es g
as a
nd lig
ht o
il / so
ft st
art l
ight
oil
• PR
-AB:
2 st
age
prog
ress
ive m
echa
nica
l gas
/ 2
stag
es lig
ht o
il - so
ft st
art l
ight
oil
• PR
: 2 st
age
prog
ress
ive m
echa
nica
l gas
- oi
l
BBCH
: Bur
ner b
ody
with
com
busti
on h
ead
→ T
C sh
ort h
ead
and
TL
long
hea
d.Ea
sy m
aint
enan
ce sy
stem
with
hin
ge fl
ange
for m
odel
s 150
0.1
- 180
0.1.
GT: G
as tr
ain
sepa
rate
→ E
N676
or E
xpor
t con
figur
ation
GTCP
: Con
necti
on p
ipe
betw
een
burn
er a
nd g
as tr
ain
star
ting
from
mod
el 1
70.1
FG
DR: G
as g
over
nor a
nd fi
lter f
or d
oubl
e so
leno
id va
lves V
CS K
rom
schr
öder
FILT
ER fo
r dou
ble
gas v
alve
s VGD
Sie
men
sKI
TTC-
...: T
ight
ness
cont
rol k
it to
be
inclu
ded
over
120
0 kW
acc
ordi
ng to
EN6
76KI
TPRE
S...:
Max
imum
pre
ssur
e sw
itch
KIT
& A
CS ca
n be
add
ed a
ccor
ding
to lo
cal r
ules
inst
alla
tions
(s
ilenc
er, b
all v
alve
, anti
vibr
ation
coup
ling.
..)
EN67
6 co
nfigu
ratio
n:
• Ga
sMul
tiBlo
c Dun
gs: c
ompa
ct d
oubl
e so
leno
id va
lve w
ith in
tegr
ated
filte
r, re
gula
tor
and
min
pre
ssur
e sw
itch
up to
mod
el M
ULTI
CALO
R 20
0.1;
• do
uble
sole
noid
valve
s VCS
Kro
msc
hröd
er: d
oubl
e so
leno
id va
lves i
nclu
ding
m
inim
um g
as p
ress
ure
switc
h +
sepa
rate
gas
gov
erno
r and
filte
r FGD
R;•
doub
le g
as va
lves w
ith a
ctua
tors
and
regu
lato
r VGD
Sie
men
s§ + g
as fi
lter;
• KI
TTC-
... T
ight
ness
cont
rol d
evice
mus
t be
inclu
ded
over
120
0 kW
acc
ordi
ng to
EN6
76;
• KI
TPRE
S...
Max
imum
pre
ssur
e sw
itch
as o
ption
or i
n co
mpl
ianc
e w
ith lo
cal s
afet
y re
gula
tions
.
EXPO
RT co
nfigu
ratio
n (o
ther
s add
ition
al o
ption
s to
be a
dded
by
inst
alle
r in
com
plia
nce
with
loca
l saf
ety
regu
latio
ns):
• Do
uble
sole
noid
valve
s VCS
Kro
msc
hröd
er: d
oubl
e so
leno
id va
lves i
nclu
ding
min
gas
pre
ssur
e sw
itch
• Do
uble
gas
valve
s with
act
uato
rs a
nd re
gula
tor V
GD S
iem
ens§
Stan
dard
vers
ion
runn
ing
on m
anua
l fue
l sel
ectio
n m
ode
and
on re
ques
t kit
for a
utom
atic f
uel c
hang
eove
r.Th
e au
tom
atic c
hang
eove
r sys
tem
can
be tr
igge
red
by a
gas
pre
ssur
e sw
itch
or b
y a
timer
.
§ VG
D Si
emen
s: d
efau
lt bl
ank
sprin
g, h
ead
pres
sure
0...
22 m
bar;
fro
m M
ULT
ICAL
OR
300.
1 ch
ange
sprin
g an
d da
mpi
ng (s
ee p
ag. 5
3).
Gas t
rain
mat
chin
g ta
ble
and
pres
sure
dro
p di
agra
ms f
or n
atur
al g
as/L
PG a
re a
vaila
ble
in th
e ga
s tra
in te
chni
cal d
ocum
enta
tion.
• LP
G KI
T up
to M
ULTI
CALO
R 20
0.1
• KI
T au
tom
atic f
uel c
hang
eove
r•
PID
mod
ulati
ng K
IT a
nd p
robe
• KI
T W
iela
nd p
lugs
• An
tivib
ratio
n co
uplin
g an
d ba
ll val
ve•
Sile
ncer
(sta
rting
from
pla
tform
260
)
• CV
: Con
tinuo
us ve
ntila
tion
vers
ion
• O
EM a
nd sp
ecia
l app
licati
on ve
rsio
n on
ly o
n re
ques
t•
KITS
WIR
L: S
wirl
syst
em fo
r flam
e cu
stom
ized
in o
ur
FLEX
SHO
P
KIT
- ACS
(see
ded
icate
d pa
ges)
AVAI
LABL
E CO
NFI
GURA
TIO
NS
ON
REQ
UES
T
All b
urne
rs 2
30-4
00V/
50Hz
are
fact
ory
test
ed a
t 400
V/50
Hz
thre
e-ph
ase.
If m
ain
supp
ly is
thre
e-ph
ase
230V
/50H
z see
in
stru
ction
man
ual f
or a
djus
tmen
ts a
nd m
odifi
catio
ns.
!
www.ecoflam-burners.com42
DUAL
FUEL
BUR
NERS
(GAS
/LIG
HT O
IL)
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
SILE
NCER
CONN
ECTI
ON
PI
PEPR
ESSU
RE [m
bar]
GAS
TRA
ING
AS G
OVE
RNO
R AN
D FI
LTER
MIN
MAX
BLAS
T TU
BECO
DEM
INM
AXCO
DETY
PEØ
CODE
TYPE
MU
LTIC
ALO
R 45
3/23
0-40
0/50
Hz19
050
0TC
3140
429
--
1750
031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/290
3142
024
VCS
125
1"31
4252
1FG
DR 1
"
TL31
4042
8-
-17
500
3142
025
VCS
240
1"1/
231
4252
3FG
DR 1
"1/2
9031
4202
4VC
S 12
51"
3142
521
FGDR
1"
MU
LTIC
ALO
R 70
3/23
0-40
0/50
Hz25
070
0
TC31
4043
1O
PT-
1550
031
4186
2VC
S 35
02"
3142
524
FGDR
2"
3031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/217
031
4202
4VC
S 12
51"
3142
521
FGDR
1"
TL31
4043
0O
PT-
1550
031
4186
2VC
S 35
02"
3142
524
FGDR
2"
3031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/217
031
4202
4VC
S 12
51"
3142
521
FGDR
1"
MU
LTIC
ALO
R 10
03/
230-
400/
50Hz
300
1000
TC31
4043
3O
PT-
2550
031
4186
2VC
S 35
02"
3142
524
FGDR
2"
4031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/216
531
4202
4VC
S 12
51"
3142
523
FGDR
1"1
/2
TL31
4043
2O
PT-
2550
031
4186
2VC
S 35
02"
3142
524
FGDR
2"
4031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/216
531
4202
4VC
S 12
51"
3142
523
FGDR
1"1
/2
MU
LTIC
ALO
R 14
03/
230-
400/
50Hz
400
1300
TC31
4043
9O
PT-
2550
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"35
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"80
500
3142
025
VCS
240
1"1/
231
4252
3FG
DR 1
"1/2
TL31
4043
8O
PT-
2550
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"35
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"80
500
3142
025
VCS
240
1"1/
231
4252
3FG
DR 1
"1/2
MU
LTIC
ALO
R 17
0.1
3/23
0-40
0/50
Hz34
217
70
TC31
4262
8O
PT
3142
069
2050
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
80
3142
075
4550
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"65
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"15
050
031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/2
TL31
4262
9O
PT
3142
069
2050
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
80
3142
075
4550
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"65
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"15
050
031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/2
MU
LTIC
ALO
R 20
0.1
3/23
0-40
0/50
Hz41
421
50
TC31
4263
0O
PT
3142
069
2350
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
8031
4219
735
500
3124
110
VGD
40.0
652"
1/2
3124
111
Filte
r DN
65
3142
075
6050
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"90
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"22
050
031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/2
TL31
4263
1O
PT
3142
069
2350
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
8031
4219
735
500
3124
110
VGD
40.0
652"
1/2
3124
111
Filte
r DN
65
3142
075
6050
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"90
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"22
050
031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/2
Tw
o st
ages
gas
/ Tw
o st
ages
ligh
t oil
MUL
TICA
LOR
www.ecoflam-burners.com 43
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
SILE
NCER
CONN
ECTI
ON
PI
PEPR
ESSU
RE [m
bar]
GAS
TRA
ING
AS G
OVE
RNO
R AN
D FI
LTER
MIN
MAX
BLAS
T TU
BECO
DEM
INM
AXCO
DETY
PEØ
CODE
TYPE
MU
LTIC
ALO
R 70
PR-
AB3/
230-
400/
50Hz
190
700
TC31
4263
2O
PT-
1550
031
4186
2VC
S 35
02"
3142
524
FGDR
2"
3031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/217
031
4202
4VC
S 12
51"
3142
521
FGDR
1"
TL31
4263
3O
PT-
1550
031
4186
2VC
S 35
02"
3142
524
FGDR
2"
3031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/217
031
4202
4VC
S 12
51"
3142
521
FGDR
1"
MU
LTIC
ALO
R 10
0 PR
-AB
3/23
0-40
0/50
Hz20
010
00
TC31
4263
4O
PT-
2550
031
4186
2VC
S 35
02"
3142
524
FGDR
2"
4031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/216
531
4202
4VC
S 12
51"
3142
523
FGDR
1"1
/2
TL31
4263
5O
PT-
2550
031
4186
2VC
S 35
02"
3142
524
FGDR
2"
4031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/216
531
4202
4VC
S 12
51"
3142
523
FGDR
1"1
/2
MU
LTIC
ALO
R 14
0 PR
-AB
3/23
0-40
0/50
Hz25
013
00
TC31
4263
6O
PT-
2550
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"35
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"80
500
3142
025
VCS
240
1"1/
231
4252
3FG
DR 1
"1/2
TL31
4263
7O
PT-
2550
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"35
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"80
500
3142
025
VCS
240
1"1/
231
4252
3FG
DR 1
"1/2
MU
LTIC
ALO
R 17
0.1
PR-A
B3/
230-
400/
50Hz
342
1770
TC31
4263
8O
PT
3142
069
2050
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
80
3142
075
4550
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"65
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"15
050
031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/2
TL31
4263
9O
PT
3142
069
2050
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
80
3142
075
4550
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"65
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"15
050
031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/2
MU
LTIC
ALO
R 20
0.1
PR-A
B3/
230-
400/
50Hz
414
2150
TC31
4264
0O
PT
3142
069
2350
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
8031
4219
735
500
3124
110
VGD
40.0
652"
1/2
3124
111
Filte
r DN
65
3142
075
6050
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"90
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"22
050
031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/2
TL31
4264
1O
PT
3142
069
2350
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
8031
4219
735
500
3124
110
VGD
40.0
652"
1/2
3124
111
Filte
r DN
65
3142
075
6050
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
"90
500
3141
862
VCS
350
2"31
4252
4FG
DR 2
"22
050
031
4202
5VC
S 24
01"
1/2
3142
523
FGDR
1"1
/2
Tw
o st
age
prog
ress
ive
mec
hani
cal g
as /
Two
stag
es li
ght o
il
www.ecoflam-burners.com44
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
SILE
NCER
CONN
ECTI
ON
PI
PEPR
ESSU
RE [m
bar]
GAS
TRA
ING
AS G
OVE
RNO
RAN
D FI
LTER
MIN
MAX
BLAS
T TU
BECO
DEM
INM
AXCO
DETY
PEØ
MU
LTIC
ALO
R 45
3/23
0-40
0/50
Hz19
050
0
TC31
4042
9O
PT-
15
360
3141
846
MB-
DLE
415
1"1/
2
incl
uded
3031
4184
5M
B-DL
E 41
21"
1/4
5031
4202
2M
B-DL
E 41
01"
8531
4184
3M
B-DL
E 40
73/
4"
TL31
4042
8O
PT-
15
360
3141
846
MB-
DLE
415
1"1/
2
incl
uded
3031
4184
5M
B-DL
E 41
21"
1/4
5031
4202
2M
B-DL
E 41
01"
8531
4184
3M
B-DL
E 40
73/
4"
MU
LTIC
ALO
R 70
3/23
0-40
0/50
Hz25
070
0
TC31
4043
1O
PT-
1736
031
4184
7M
B-DL
E 42
02"
incl
uded
2531
4184
6M
B-DL
E 41
51"
1/2
7531
4202
2M
B-DL
E 41
01"
TL31
4043
0O
PT-
1736
031
4184
7M
B-DL
E 42
02"
incl
uded
2531
4184
6M
B-DL
E 41
51"
1/2
7531
4202
2M
B-DL
E 41
01"
MU
LTIC
ALO
R 10
03/
230-
400/
50Hz
300
1000
TC31
4043
3O
PT-
2736
031
4184
7M
B-DL
E 42
02"
incl
uded
3531
4184
6M
B-DL
E 41
51"
1/2
7531
4184
5M
B-DL
E 41
21"
1/4
TL31
4043
2O
PT-
2736
031
4184
7M
B-DL
E 42
02"
incl
uded
3531
4184
6M
B-DL
E 41
51"
1/2
7531
4184
5M
B-DL
E 41
21"
1/4
MU
LTIC
ALO
R 14
03/
230-
400/
50Hz
400
1300
TC31
4043
9O
PT-
4036
031
4184
7M
B-DL
E 42
02"
incl
uded
5031
4184
6M
B-DL
E 41
51"
1/2
100
3141
845
MB-
DLE
412
1"1/
4
TL31
4043
8O
PT-
4036
031
4184
7M
B-DL
E 42
02"
incl
uded
5031
4184
6M
B-DL
E 41
51"
1/2
100
3141
845
MB-
DLE
412
1"1/
4
MU
LTIC
ALO
R 17
0.1
3/23
0-40
0/50
Hz34
217
70TC
3142
628
OPT
3142
075
6036
031
4184
7M
B-DL
E 42
02"
incl
uded
8531
4184
6M
B-DL
E 41
51"
1/2
TL31
4262
9O
PT31
4207
560
360
3141
847
MB-
DLE
420
2"in
clud
ed85
3141
846
MB-
DLE
415
1"1/
2
MU
LTIC
ALO
R 20
0.1
3/23
0-40
0/50
Hz41
421
50TC
3142
630
OPT
3142
075
7536
031
4184
7M
B-DL
E 42
02"
incl
uded
100
3141
846
MB-
DLE
415
1"1/
2
TL31
4263
1O
PT31
4207
575
360
3141
847
MB-
DLE
420
2"in
clud
ed10
031
4184
6M
B-DL
E 41
51"
1/2
Tw
o st
ages
gas
/ Tw
o st
ages
ligh
t oil
- Mul
tiBlo
c gas
trai
n
www.ecoflam-burners.com 45
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
SILE
NCER
CONN
ECTI
ON
PI
PEPR
ESSU
RE [m
bar]
GAS
TRA
ING
AS G
OVE
RNO
RAN
D FI
LTER
MIN
MAX
BLAS
T TU
BECO
DEM
INM
AXCO
DETY
PEØ
MU
LTIC
ALO
R 70
PR-
AB3/
230-
400/
50Hz
190
700
TC31
4263
2O
PT-
1736
031
4184
7M
B-DL
E 42
02"
incl
uded
2531
4184
6M
B-DL
E 41
51"
1/2
7531
4202
2M
B-DL
E 41
01"
TL31
4263
3O
PT-
1736
031
4184
7M
B-DL
E 42
02"
incl
uded
2531
4184
6M
B-DL
E 41
51"
1/2
7531
4202
2M
B-DL
E 41
01"
MU
LTIC
ALO
R 10
0 PR
-AB
3/23
0-40
0/50
Hz20
010
00
TC31
4263
4O
PT-
2736
031
4184
7M
B-DL
E 42
02"
incl
uded
3531
4184
6M
B-DL
E 41
51"
1/2
7531
4184
5M
B-DL
E 41
21"
1/4
TL31
4263
5O
PT-
2736
031
4184
7M
B-DL
E 42
02"
incl
uded
3531
4184
6M
B-DL
E 41
51"
1/2
7531
4184
5M
B-DL
E 41
21"
1/4
MU
LTIC
ALO
R 14
0 PR
-AB
3/23
0-40
0/50
Hz25
013
00
TC31
4263
6O
PT-
4036
031
4184
7M
B-DL
E 42
02"
incl
uded
5031
4184
6M
B-DL
E 41
51"
1/2
100
3141
845
MB-
DLE
412
1"1/
4
TL31
4263
7O
PT-
4036
031
4184
7M
B-DL
E 42
02"
incl
uded
5031
4184
6M
B-DL
E 41
51"
1/2
100
3141
845
MB-
DLE
412
1"1/
4
MU
LTIC
ALO
R 17
0.1
PR-A
B3/
230-
400/
50Hz
342
1770
TC31
4263
8O
PT31
4207
560
360
3141
847
MB-
DLE
420
2"in
clud
ed85
3141
846
MB-
DLE
415
1"1/
2
TL31
4263
9O
PT31
4207
560
360
3141
847
MB-
DLE
420
2"in
clud
ed85
3141
846
MB-
DLE
415
1"1/
2
MU
LTIC
ALO
R 20
0.1
PR-A
B3/
230-
400/
50Hz
414
2150
TC31
4264
0O
PT31
4207
575
360
3141
847
MB-
DLE
420
2"in
clud
ed10
031
4184
6M
B-DL
E 41
51"
1/2
TL31
4264
1O
PT31
4207
575
360
3141
847
MB-
DLE
420
2"in
clud
ed10
031
4184
6M
B-DL
E 41
51"
1/2
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
SILE
NCE
RM
INM
AXBL
AST
TUBE
CODE
MU
LTIC
ALO
R 70
PR
- 3/2
30-4
00/5
0Hz
250
700
TLon
requ
est
OPT
MU
LTIC
ALO
R 10
0 PR
- 3/
230-
400/
50Hz
300
1000
TLon
requ
est
OPT
MU
LTIC
ALO
R 14
0 PR
- 3/
230-
400/
50Hz
400
1300
TLon
requ
est
OPT
MU
LTIC
ALO
R 17
0.1
PR -
3/23
0-40
0/50
Hz34
217
70TL
on re
ques
tO
PTM
ULT
ICAL
OR
200.
1 PR
- 3/
230-
400/
50Hz
414
2150
TLon
requ
est
OPT
Tw
o st
age
prog
ress
ive
mec
hani
cal g
as /
Two
stag
es li
ght o
il - M
ultiB
loc g
as tr
ain
Tw
o st
age
prog
ress
ive
mec
hani
cal g
as /
Two
stag
e pr
ogre
ssiv
e m
echa
nica
l lig
ht o
il - O
nly
body
www.ecoflam-burners.com46
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
SILE
NCER
CONN
ECTI
ON
PI
PEPR
ESSU
RE [m
bar]
GAS
TRA
IN (§
)G
AS G
OVE
RNO
R AN
D FI
LTER
MIN
MAX
BLAS
T TU
BECO
DEM
INM
AXCO
DETY
PEØ
CODE
TYPE
MU
LTIC
ALO
R 30
0.1
PR3/
400/
50Hz
630
3000
TC31
4376
5O
PT
3142
069+
3142
073
2250
031
4186
9VG
D 40
.100
DN10
031
4220
5Fi
lter D
N10
0
3142
069
3550
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
8031
4219
755
500
3124
110
VGD
40.0
65DN
6531
2411
1Fi
lter D
N65
3142
075
100
500
3123
860
VGD
20.5
032"
3121
384
Filte
r 2"
TL31
4376
6O
PT
3142
069+
3142
073
2250
031
4186
9VG
D 40
.100
DN10
031
4220
5Fi
lter D
N10
0
3142
069
3550
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
8031
4219
755
500
3124
110
VGD
40.0
65DN
6531
2411
1Fi
lter D
N65
3142
075
100
500
3123
860
VGD
20.5
032"
3121
384
Filte
r 2"
MU
LTIC
ALO
R 40
0.1
PR3/
400/
50Hz
875
3900
TC31
4376
7O
PT
3142
069+
3142
073
3050
031
4186
9VG
D 40
.100
DN10
031
4220
5Fi
lter D
N10
0
3142
069
5050
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
8031
4219
790
500
3124
110
VGD
40.0
65DN
6531
2411
1Fi
lter D
N65
3142
075
170
500
3123
860
VGD
20.5
032"
3121
384
Filte
r 2"
TL31
4376
8O
PT
3142
069+
3142
073
3050
031
4186
9VG
D 40
.100
DN10
031
4220
5Fi
lter D
N10
0
3142
069
5050
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
8031
4219
790
500
3124
110
VGD
40.0
65DN
6531
2411
1Fi
lter D
N65
3142
075
170
500
3123
860
VGD
20.5
032"
3121
384
Filte
r 2"
MU
LTIC
ALO
R 50
0.1
PR3/
400/
50Hz
1200
5000
TC31
4376
9O
PT
3142
198
3550
031
4266
6VG
D 40
.125
DN12
531
4220
6Fi
lter D
N12
531
4207
0+31
4207
345
500
3141
869
VGD
40.1
00DN
100
3142
205
Filte
r DN
100
3142
070
7550
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
8031
4207
114
050
031
2411
0VG
D 40
.065
DN65
3124
111
Filte
r DN
6531
4207
525
050
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
''
TL31
4377
0O
PT
3142
198
3550
031
4266
6VG
D 40
.125
DN12
531
4220
6Fi
lter D
N12
531
4207
0+31
4207
345
500
3141
869
VGD
40.1
00DN
100
3142
205
Filte
r DN
100
3142
070
7550
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
8031
4207
114
050
031
2411
0VG
D 40
.065
DN65
3124
111
Filte
r DN
6531
4207
525
050
031
2386
0VG
D 20
.503
2"31
2138
4Fi
lter 2
''
MU
LTIC
ALO
R 60
0.1
PR3/
400/
50Hz
1500
5800
TC31
4377
1O
PT
3142
198
5050
031
4266
6VG
D 40
.125
DN12
531
4220
6Fi
lter D
N12
531
4207
0+31
4207
360
500
3141
869
VGD
40.1
00DN
100
3142
205
Filte
r DN
100
3142
070
100
500
3142
026
VGD
40.0
80DN
8031
4208
8Fi
lter D
N80
3142
071
180
500
3124
110
VGD
40.0
65DN
6531
2411
1Fi
lter D
N65
3142
075
340
500
3123
860
VGD
20.5
032"
3121
384
Filte
r 2''
TL31
4377
2O
PT
3142
198
5050
031
4266
6VG
D 40
.125
DN12
531
4220
6Fi
lter D
N12
531
4207
0+31
4207
360
500
3141
869
VGD
40.1
00DN
100
3142
205
Filte
r DN
100
3142
070
100
500
3142
026
VGD
40.0
80DN
8031
4208
8Fi
lter D
N80
3142
071
180
500
3124
110
VGD
40.0
65DN
6531
2411
1Fi
lter D
N65
3142
075
340
500
3123
860
VGD
20.5
032"
3121
384
Filte
r 2''
Tw
o st
age
prog
ress
ive
mec
hani
cal g
as /
Two
stag
e pr
ogre
ssiv
e m
echa
nica
l lig
ht o
il
§ VG
D Si
emen
s: d
efau
lt bl
ank
sprin
g, h
ead
pres
sure
0...
22 m
bar;
from
MU
LTIC
ALO
R 30
00.1
chan
ge sp
ring
and
dam
ping
(see
pag
. 53)
!
www.ecoflam-burners.com 47
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
SILE
NCER
CONN
ECTI
ON
PI
PEPR
ESSU
RE [m
bar]
GAS
TRA
IN (§
)G
AS G
OVE
RNO
R AN
D FI
LTER
MIN
MAX
BLAS
T TU
BECO
DEM
INM
AXCO
DETY
PEØ
CODE
TYPE
MU
LTIC
ALO
R 70
0.1
PR3/
400/
50Hz
1500
7500
TC31
4377
3O
PT
3142
422+
31
4242
560
500
3142
666
VGD
40.1
25DN
125
3142
206
Filte
r DN
125
3142
422
7531
4186
9VG
D 40
.100
DN10
031
4220
5Fi
lter D
N10
031
4242
414
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
8031
4242
328
031
2411
0VG
D 40
.065
DN65
3124
111
Filte
r DN
65
MU
LTIC
ALO
R 80
0.1
PR3/
400/
50Hz
2000
8500
TC31
4377
4O
PT
3142
422+
31
4242
585
500
3142
666
VGD
40.1
25DN
125
3142
206
Filte
r DN
125
3142
422
110
3141
869
VGD
40.1
00DN
100
3142
205
Filte
r DN
100
3142
424
210
3142
026
VGD
40.0
80DN
8031
4208
8Fi
lter D
N80
3142
423
410
3124
110
VGD
40.0
65DN
6531
2411
1Fi
lter D
N65
MU
LTIC
ALO
R 10
00.1
PR
3/40
0/50
Hz25
0010
500
TC31
4377
5O
PT
3142
422+
31
4242
511
5
500
3142
666
VGD
40.1
25DN
125
3142
206
Filte
r DN
125
3142
422
165
3141
869
VGD
40.1
00DN
100
3142
205
Filte
r DN
100
3142
424
290
3142
026
VGD
40.0
80DN
8031
4208
8Fi
lter D
N80
3142
423
550
3124
110
VGD
40.0
65DN
6531
2411
1Fi
lter D
N65
MU
LTIC
ALO
R 12
00.1
PR
3/40
0/50
Hz27
0013
000
TC31
4377
6O
PT
3142
422+
31
4242
517
550
031
4266
6VG
D 40
.125
DN12
531
4220
6Fi
lter D
N12
5
3142
422
230
3141
869
VGD
40.1
00DN
100
3142
205
Filte
r DN
100
3142
424
420
3142
026
VGD
40.0
80DN
8031
4208
8Fi
lter D
N80
MU
LTIC
ALO
R 15
00.1
PR
3/40
0/50
Hz36
9015
000
TC31
4377
7O
PT
3142
422+
31
4242
515
050
031
4266
6VG
D 40
.125
DN12
531
4220
6Fi
lter D
N12
5
3142
422
230
3141
869
VGD
40.1
00DN
100
3142
205
Filte
r DN
100
3142
424
450
3142
026
VGD
40.0
80DN
8031
4208
8Fi
lter D
N80
MU
LTIC
ALO
R 18
00.1
PR
3/40
0/50
Hz40
0017
000
TC31
4377
8O
PT31
4242
2+
3142
425
210
500
3142
666
VGD
40.1
25DN
125
3142
206
Filte
r DN
125
3142
422
330
3141
869
VGD
40.1
00DN
100
3142
205
Filte
r DN
100
DESC
RIPT
ION
Sile
ncer
see
acce
ssor
ies p
age
Tigh
tnes
s con
trol
see
acce
ssor
ies p
age
Mod
ulati
on k
itse
e ac
cess
orie
s pag
ePr
obe
see
acce
ssor
ies p
age
LPG
kit
see
acce
ssor
ies p
age
Addi
tiona
l gas
acc
esso
ries
see
acce
ssor
ies p
age
Auto
mati
c fue
l cha
ngeo
ver k
itse
e ac
cess
orie
s pag
eO
il pum
ping
uni
tse
e ac
cess
orie
s pag
e
KIT
- AC
CESS
ORI
ES
MU
LTIC
ALO
R - D
UO
BLO
CK A
ND
ELEC
TRO
NIC
BU
RNER
SVe
rsio
ns fr
om 2
to 2
5 M
W a
re a
vaila
ble
on re
ques
t for
sele
cted
out
put t
o m
atch
mai
n bo
ilers
and
indu
stry
app
licati
on.
§ VG
D Si
emen
s: d
efau
lt bl
ank
sprin
g, h
ead
pres
sure
0...
22 m
bar;
from
MU
LTIC
ALO
R 30
00.1
chan
ge sp
ring
and
dam
ping
(see
pag
. 53)
!
www.ecoflam-burners.com48
DUAL
FUEL
BUR
NERS
(GAS
/HEA
VY O
IL)
MUL
TIFL
AM -
Max
visc
. 50°
E at
50°
C
MU
LTIF
LAM
rang
e is
avai
labl
e in
the
follo
win
g ve
rsio
ns a
nd is
del
ivere
d in
a
mod
ular
syst
em o
f box
es:
• PA
B: 2
stag
es g
as a
nd h
eavy
oil /
soft
star
t hea
vy o
il•
PR: 2
stag
e pr
ogre
ssive
mec
hani
cal g
as -
heav
y oi
l
BBCH
: Bur
ner b
ody
with
com
busti
on h
ead
→ T
C sh
ort h
ead
and
TL lo
ng h
ead
in D
vers
ion
for h
eavy
oil w
ith m
ax v
isc 5
0°E
at 5
0°C.
El
ectr
ical p
re-h
eate
r pre
asse
mbl
ed in
to th
e bu
rner
bod
y.
All b
urne
rs b
ody
are
deliv
ered
with
slid
ing
bar s
yste
m u
p to
m
odel
120
0.1
and
with
hin
ge fl
ange
for m
odel
s 200
.1
and
1500
.1 -
1800
.1.
GT: G
as tr
ain
sepa
rate
→ E
N676
or E
xpor
t con
figur
ation
GTCP
: Con
necti
on p
ipe
betw
een
burn
er a
nd g
as tr
ain
star
ting
from
mod
el 1
70.1
FG
DR: G
as g
over
nor a
nd fi
lter f
or d
oubl
e so
leno
id va
lves V
CS K
rom
schr
öder
FILT
ER fo
r dou
ble
gas v
alve
s VGD
Sie
men
sKI
TTC-
...: T
ight
ness
cont
rol k
it to
be
inclu
ded
over
120
0 kW
acc
ordi
ng to
EN6
76KI
TPRE
S...:
Max
imum
pre
ssur
e sw
itch
KIT
& A
CS ca
n be
add
ed a
ccor
ding
to lo
cal r
ules
inst
alla
tions
(sile
ncer
, bal
l val
ve, a
ntivi
brati
on co
uplin
g...)
EN67
6 co
nfigu
ratio
n:•
doub
le g
as va
lves w
ith a
ctua
tors
and
regu
lato
r VGD
Sie
men
s§ + g
as fi
lter;
• KI
TTC-
... T
ight
ness
cont
rol d
evice
mus
t be
inclu
ded
over
120
0 kW
acc
ordi
ng to
EN6
76;
• KI
TPRE
S...
Max
imum
pre
ssur
e sw
itch
as o
ption
or i
n co
mpl
ianc
e w
ith lo
cal s
afet
y re
gula
tions
.
§ VG
D Si
emen
s: d
efau
lt bl
ank
sprin
g, h
ead
pres
sure
0...
22 m
bar;
fro
m M
ULT
IFLA
M 3
00.1
chan
ge sp
ring
and
dam
ping
(see
pag
. 53)
.
Gas t
rain
mat
chin
g ta
ble
and
pres
sure
dro
p di
agra
ms f
or n
atur
al g
as/L
PG a
re a
vaila
ble
in th
e ga
s tra
in te
chni
cal d
ocum
enta
tion.
Stan
dard
vers
ion
runn
ing
on m
anua
l fue
l sel
ectio
n m
ode
and
on re
ques
t kit
for a
utom
atic f
uel c
hang
eove
r.Th
e au
tom
atic c
hang
eove
r sys
tem
can
be tr
igge
red
by a
gas
pre
ssur
e sw
itch
or b
y a
timer
.
• KI
T au
tom
atic f
uel c
hang
eove
r•
PID
mod
ulati
ng K
IT a
nd p
robe
• KI
T W
iela
nd p
lugs
• An
tivib
ratio
n co
uplin
g an
d ba
ll val
ve•
Sile
ncer
(sta
rting
from
pla
tform
260
)
• CV
: Con
tinuo
us ve
ntila
tion
vers
ion
• O
EM a
nd sp
ecia
l app
licati
on ve
rsio
n on
ly o
n re
ques
t•
KITS
WIR
L: S
wirl
syst
em fo
r flam
e cu
stom
ized
in o
ur
FLEX
SHO
P
KIT
- ACS
(see
ded
icate
d pa
ges)
AVAI
LABL
E CO
NFI
GURA
TIO
NS
ON
REQ
UES
T
All b
urne
rs 2
30-4
00V/
50Hz
are
fact
ory
test
ed a
t 400
V/50
Hz
thre
e-ph
ase.
If m
ain
supp
ly is
thre
e-ph
ase
230V
/50H
z see
in
stru
ction
man
ual f
or a
djus
tmen
ts a
nd m
odifi
catio
ns.
!
www.ecoflam-burners.com 49
DUAL
FUEL
BUR
NERS
(GAS
/HEA
VY O
IL)
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
SILE
NCER
CONN
ECTI
ON
PI
PEPR
ESSU
RE [m
bar]
GAS
TRA
ING
AS G
OVE
RNO
R AN
D FI
LTER
MIN
MAX
BLAS
T TU
BECO
DEM
INM
AXCO
DETY
PEØ
CODE
TYPE
MU
LTIF
LAM
300
.1 P
R3/
400/
50Hz
630
3000
TC31
4377
9O
PT
3142
073
2250
031
4186
9VG
D 40
.100
DN10
031
4220
5Fi
lter D
N10
0
-35
500
3142
026
VGD
40.0
80DN
8031
4208
8Fi
lter D
N80
3142
935
5550
031
2411
0VG
D 40
.065
DN65
3124
111
Filte
r DN
65
3143
080
100
500
3123
860
VGD
20.5
032"
3121
384
Filte
r 2"
TL31
4378
0O
PT
3142
073
2250
031
4186
9VG
D 40
.100
DN10
031
4220
5Fi
lter D
N10
0
-35
500
3142
026
VGD
40.0
80DN
8031
4208
8Fi
lter D
N80
3142
935
5550
031
2411
0VG
D 40
.065
DN65
3124
111
Filte
r DN
65
3143
080
100
500
3123
860
VGD
20.5
032"
3121
384
Filte
r 2"
MU
LTIF
LAM
400
.1 P
R3/
400/
50Hz
875
3900
TC31
4378
1O
PT
3142
073
3050
031
4186
9VG
D 40
.100
DN10
031
4220
5Fi
lter D
N10
0
-50
500
3142
026
VGD
40.0
80DN
8031
4208
8Fi
lter D
N80
3142
935
9050
031
2411
0VG
D 40
.065
DN65
3124
111
Filte
r DN
65
3143
080
170
500
3123
860
VGD
20.5
032"
3121
384
Filte
r 2"
TL31
4378
2O
PT
3142
073
3050
031
4186
9VG
D 40
.100
DN10
031
4220
5Fi
lter D
N10
0
-50
500
3142
026
VGD
40.0
80DN
8031
4208
8Fi
lter D
N80
3142
935
9050
031
2411
0VG
D 40
.065
DN65
3124
111
Filte
r DN
65
3143
080
170
500
3123
860
VGD
20.5
032"
3121
384
Filte
r 2"
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
SILE
NCER
CONN
ECTI
ON
PI
PEPR
ESSU
RE [m
bar]
GAS
TRA
ING
AS G
OVE
RNO
R AN
D FI
LTER
MIN
MAX
BLAS
T TU
BECO
DEM
INM
AXCO
DETY
PEØ
CODE
TYPE
MU
LTIF
LAM
200
.13/
230-
400/
50Hz
414
2150
TC31
4266
9O
PT
-35
500
3142
026
VGD
40.0
80DN
8031
4208
8Fi
lter D
N80
3142
935
5550
031
2411
0VG
D 40
.065
DN65
3124
111
Filte
r DN
65
3143
080
100
500
3123
860
VGD
20.5
032"
3121
384
Filte
r 2"
TL31
4267
0O
PT
-35
500
3142
026
VGD
40.0
80DN
8031
4208
8Fi
lter D
N80
3142
935
5550
031
2411
0VG
D 40
.065
DN65
3124
111
Filte
r DN
65
3143
080
100
500
3123
860
VGD
20.5
032"
3121
384
Filte
r 2"
Tw
o st
ages
gas
/ Tw
o st
ages
hea
vy o
il - 5
0°E
fuel
visc
osity
at 5
0°C
Tw
o st
age
prog
ress
ive
mec
hani
cal g
as /
Two
stag
e pr
ogre
ssiv
e m
echa
nica
l hea
vy o
il - 5
0°E
fuel
visc
osity
at 5
0°C
§ VG
D Si
emen
s: d
efau
lt bl
ank
sprin
g, h
ead
pres
sure
0...
22 m
bar;
from
MU
LTIF
LAM
300
0.1
chan
ge sp
ring
and
dam
ping
(see
pag
. 53)
MUL
TIFL
AM -
Max
visc
. 50°
E at
50°
C
!
www.ecoflam-burners.com50
DESC
RIPT
ION
Sile
ncer
see
acce
ssor
ies p
age
Tigh
tnes
s con
trol
see
acce
ssor
ies p
age
Mod
ulati
on k
itse
e ac
cess
orie
s pag
ePr
obe
see
acce
ssor
ies p
age
LPG
kit
see
acce
ssor
ies p
age
Addi
tiona
l gas
acc
esso
ries
see
acce
ssor
ies p
age
Auto
mati
c fue
l cha
ngeo
ver k
itse
e ac
cess
orie
s pag
eO
il hea
ting
pum
ping
uni
tse
e ac
cess
orie
s pag
e
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
SILE
NCER
CONN
ECTI
ON
PI
PEPR
ESSU
RE [m
bar]
GAS
TRA
ING
AS G
OVE
RNO
R AN
D FI
LTER
MIN
MAX
BLAS
T TU
BECO
DEM
INM
AXCO
DETY
PEØ
CODE
TYPE
MU
LTIF
LAM
500.
1 PR
3/40
0/50
Hz12
0050
00
TC31
4378
3O
PT
3143
105
3550
031
4266
6VG
D 40
.125
DN12
531
4220
6Fi
lter D
N12
5
3142
073
4550
031
4186
9VG
D 40
.100
DN10
031
4220
5Fi
lter D
N10
0
-75
500
3142
026
VGD
40.0
80DN
8031
4208
8Fi
lter D
N80
3142
935
140
500
3124
110
VGD
40.0
65DN
6531
2411
1Fi
lter D
N65
3143
080
250
500
3123
860
VGD
20.5
032"
3121
384
Filte
r 2''
TL31
4378
4O
PT
3143
105
3550
031
4266
6VG
D 40
.125
DN12
531
4220
6Fi
lter D
N12
5
3142
073
4550
031
4186
9VG
D 40
.100
DN10
031
4220
5Fi
lter D
N10
0
-75
500
3142
026
VGD
40.0
80DN
8031
4208
8Fi
lter D
N80
3142
935
140
500
3124
110
VGD
40.0
65DN
6531
2411
1Fi
lter D
N65
3143
080
250
500
3123
860
VGD
20.5
032"
3121
384
Filte
r 2''
MU
LTIF
LAM
600.
1 PR
3/40
0/50
Hz15
0058
00
TC31
4378
5O
PT
3143
105
5050
031
4266
6VG
D 40
.125
DN12
531
4220
6Fi
lter D
N12
5
3142
073
6050
031
4186
9VG
D 40
.100
DN10
031
4220
5Fi
lter D
N10
0
-10
050
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
80
3142
935
180
500
3124
110
VGD
40.0
65DN
6531
2411
1Fi
lter D
N65
3143
080
340
500
3123
860
VGD
20.5
032"
3121
384
Filte
r 2''
TL31
4378
6O
PT
3143
105
5050
031
4266
6VG
D 40
.125
DN12
531
4220
6Fi
lter D
N12
5
3142
073
6050
031
4186
9VG
D 40
.100
DN10
031
4220
5Fi
lter D
N10
0
-10
050
031
4202
6VG
D 40
.080
DN80
3142
088
Filte
r DN
80
3142
935
180
500
3124
110
VGD
40.0
65DN
6531
2411
1Fi
lter D
N65
3143
080
340
500
3123
860
VGD
20.5
032"
3121
384
Filte
r 2''
KIT
- AC
CESS
ORI
ES
§ VG
D Si
emen
s: d
efau
lt bl
ank
sprin
g, h
ead
pres
sure
0...
22 m
bar;
from
MU
LTIF
LAM
300
0.1
chan
ge sp
ring
and
dam
ping
(see
pag
. 53)
!
www.ecoflam-burners.com 51
MO
DEL
OU
TPU
T [k
W]
BURN
ER B
ODY
SILE
NCE
RPR
ESSU
RE [m
bar]
GAS
TRA
IN (§
)G
AS G
OVE
RNO
R AN
D FI
LTER
MIN
MAX
BLAS
T TU
BECO
DEM
INM
AXTY
PEØ
MU
LTIF
LAM
700
.1 P
R3/
400/
50Hz
1500
7500
TC-
OPT
60
500
VGD
40.1
25DN
125
Filte
r DN
125
75VG
D 40
.100
DN10
0Fi
lter D
N10
0
140
VGD
40.0
80DN
80Fi
lter D
N80
280
VGD
40.0
65DN
65Fi
lter D
N65
MU
LTIF
LAM
800
.1 P
R3/
400/
50Hz
2000
8500
TC-
OPT
85
500
VGD
40.1
25DN
125
Filte
r DN
125
110
VGD
40.1
00DN
100
Filte
r DN
100
210
VGD
40.0
80DN
80Fi
lter D
N80
410
VGD
40.0
65DN
65Fi
lter D
N65
MU
LTIF
LAM
100
0.1
PR3/
400/
50Hz
2500
1050
0TC
-O
PT
115
500
VGD
40.1
25DN
125
Filte
r DN
125
165
VGD
40.1
00DN
100
Filte
r DN
100
290
VGD
40.0
80DN
80Fi
lter D
N80
550
VGD
40.0
65DN
65Fi
lter D
N65
MU
LTIF
LAM
120
0.1
PR3/
400/
50Hz
2700
1300
0TC
-O
PT
160
500
VGD
40.1
50DN
150
Filte
r DN
150
175
VGD
40.1
25DN
125
Filte
r DN
125
230
VGD
40.1
00DN
100
Filte
r DN
100
420
VGD
40.0
80DN
80Fi
lter D
N80
MU
LTIF
LAM
150
0.1
PR3/
400/
50Hz
3690
1500
0TC
-O
PT
125
500
VGD
40.1
50DN
150
Filte
r DN
150
150
VGD
40.1
25DN
125
Filte
r DN
125
230
VGD
40.1
00DN
100
Filte
r DN
100
450
VGD
40.0
80DN
80Fi
lter D
N80
MU
LTIF
LAM
180
0.1
PR3/
400/
50Hz
4000
1700
0TC
-O
PT
175
500
VGD
40.1
50DN
150
Filte
r DN
150
210
VGD
40.1
25DN
125
Filte
r DN
125
330
VGD
40.1
00DN
100
Filte
r DN
100
Tw
o st
age
prog
ress
ive
mec
hani
cal g
as /
Two
stag
e pr
ogre
ssiv
e m
echa
nica
l hea
vy o
il - 5
0°E
fuel
visc
osity
at 5
0°C
MU
LTIF
LAM
- DU
OBL
OCK
AN
D EL
ECTR
ON
IC B
URN
ERS
Vers
ions
from
2 to
25
MW
are
ava
ilabl
e on
requ
est f
or se
lect
ed o
utpu
t to
mat
ch m
ain
boile
rs a
nd in
dust
ry a
pplic
ation
.
§ VG
D Si
emen
s: d
efau
lt bl
ank
sprin
g, h
ead
pres
sure
0...
22 m
bar;
from
MU
LTIF
LAM
300
0.1
chan
ge sp
ring
and
dam
ping
(see
pag
. 53)
!
www.ecoflam-burners.com52
CON
FIG
URA
TIO
NDE
SCRI
PTIO
NDE
SIG
NAT
ION
ØCO
DE
EN67
6
Mul
tiBlo
c Dun
gs: c
ompa
ct d
oubl
e so
leno
id va
lve
with
inte
grat
ed fi
lter,
regu
lato
r and
min
pre
ssur
e sw
itch.
WAR
NIN
G:EN
676
com
pulso
ry k
it an
d ac
cess
orie
s in
orde
r to
com
ply
to th
e sa
fety
regu
latio
ns.
Addi
tiona
l acc
esso
ries a
nd k
its sh
all b
e in
stal
led
by
the
inst
alle
r in
acco
rdan
ce to
the
loca
l saf
ety
re
gula
tions
and
code
s of p
racti
se.
MB-
DLE
Mul
tiBlo
c Dun
gs
MAX
GAS
40-
250
GT-D
1-M
BC65
DLE-
RP15
-MAX
GAS4
0-12
0RP
15
- 1/2
"31
4188
5
GT-D
1-M
BC12
0DLE
-RP2
0-M
AXGA
S40-
120
RP 2
0 - 3
/4"
3141
886
GT-D
1-M
BDLE
403-
RP15
-MAX
GAS4
0-12
0RP
15
- 1/2
"31
2394
4GT
-D1-
MBD
LE40
5-RP
20-M
AXGA
S40-
120
RP 2
0 - 3
/4"
3123
560
GT-D
1-M
BDLE
407-
RP20
-MAX
GAS1
70-2
50RP
20
- 3/4
"31
2352
5GT
-D1-
MBD
LE41
0-RP
25-M
AXGA
S170
-250
RP 2
5 - 1
"31
2394
7GT
-D1-
MBD
LE41
2-RP
32-M
AXGA
S170
-250
RP 3
2 - 1
"1/4
3141
899
GT-D
1-M
BDLE
415-
RP40
-MAX
GAS1
70-2
50RP
40
- 1"1
/231
2396
9DE
SCRI
PTIO
NDE
SIG
NAT
ION
ØCO
DE
MB-
ZRDL
E M
ultiB
loc D
ungs
M
AX G
AS 4
0-25
0
GT-D
2-M
BZRD
LE40
5-RP
20-M
AXGA
S40-
120
RP 2
0 - 3
/4"
3123
960
GT-D
2-M
BZRD
LE40
7-RP
20-M
AXGA
S170
-250
RP 2
0 - 3
/4"
3123
961
GT-D
2-M
BZRD
LE41
0-RP
25-M
AXGA
S170
-250
RP 2
5 - 1
"31
2396
2GT
-D2-
MBZ
RDLE
412-
RP32
-MAX
GAS1
70-2
50RP
32
- 1"1
/431
4190
1
GT-D
2-M
BZRD
LE41
5-RP
40-M
AXGA
S170
-250
RP 4
0 - 1
"1/2
3123
879
DESC
RIPT
ION
DESI
GN
ATIO
NØ
CODE
MB-
DLE
Mul
tiBlo
c Dun
gs
MAX
GAS
350
-500
GT-D
2-M
BDLE
407-
RP20
-MAX
GAS3
50-5
00RP
20
- 3/4
"31
4239
2
GT-D
2-M
BDLE
410-
RP25
-MAX
GAS3
50-5
00RP
25
- 1"
3142
665
GT-D
2-M
BDLE
412-
RP32
-MAX
GAS3
50-5
00RP
32
- 1"1
/431
4229
5GT
-D2-
MBD
LE41
5-RP
40-M
AXGA
S350
-500
RP 4
0 - 1
"1/2
3142
296
CON
FIG
URA
TIO
NDE
SCRI
PTIO
NDE
SIG
NAT
ION
ØCO
DE
Expo
rtEN
676
+ FG
DR
Doub
le so
leno
id va
lves V
CS K
rom
schr
öder
and
m
in p
ress
ure
switc
h +
ACS
gas g
over
nor &
filte
r
VCS
Krom
schr
öder
M
AX G
AS 1
70-2
50GT
-K1-
VCS1
25-R
P25-
MAX
GAS1
70-2
50RP
25
- 1"
3141
906
GT-K
1-VC
S240
-RP4
0-M
AXGA
S170
-250
RP 4
0 - 1
"1/2
3142
251
DESC
RIPT
ION
DESI
GN
ATIO
NØ
CODE
VCS
Krom
schr
öder
M
AX G
AS 3
50-5
00
GT-K
2-VC
S125
-RP2
5-M
AXGA
S350
-500
/MU
LTI
RP 2
5 - 1
"31
4237
4
GT-K
2-VC
S240
-RP4
0-M
AXGA
S350
-500
/MU
LTI
RP 4
0 - 1
"1/2
3142
375
GT-K
2-VC
S350
-RP5
0-M
AXGA
S350
-500
/MU
LTI
RP 5
0 - 2
"31
4237
6
CON
FIG
URA
TIO
NDE
SCRI
PTIO
NDE
SIG
NAT
ION
ØCO
DE
Onl
y Ex
port
(not
EN6
76)
Expo
rt g
as tr
ains
M
AX G
AS 4
0-25
0
GT-D
1-GB
LE05
5-RP
15-M
AXGA
S40-
120
RP 1
5 - 1
/2"
3142
027
GT-B
1-E6
GSRP
-RP1
5-M
AXGA
S40-
120
RP 1
5 - 1
/2"
3141
888
GT-B
1-EG
12L-
RP15
-MAX
GAS4
0-12
0RP
15
- 1/2
"31
4188
7GT
-K1-
VAS1
25-R
P25-
MAX
GAS1
70-2
50RP
25
- 1"
3142
815
GT-K
1-VA
S240
-RP4
0-M
AXGA
S170
-250
RP 4
0 - 1
"1/2
3142
816
GAS
TRAI
N: M
AX G
AS
www.ecoflam-burners.com 53
GAS
TRAI
N AN
D GT
CP: B
LU -
MUL
TICA
LOR
- MUL
TIFL
AMM
B-DL
E M
ULT
IBLO
C DU
NG
SDE
SIG
NAT
ION
ØCO
DE
EN67
6M
ultiB
loc D
ungs
: com
pact
dou
ble
sole
noid
valve
with
in
tegr
ated
filte
r, re
gula
tor a
nd m
in p
ress
ure
switc
h.
GT-D
2-M
BDLE
407-
RP20
-BLU
/MU
LTI
RP 2
0 - 3
/4"
3141
843
GT-D
2-M
BDLE
410-
RP25
-BLU
/MU
LTI
RP 2
5 - 1
"31
4202
2GT
-D2-
MBD
LE41
2-RP
32-B
LU/M
ULT
IRP
32
- 1"1
/431
4184
5GT
-D2-
MBD
LE41
5-RP
40-B
LU/M
ULT
IRP
40
- 1"1
/231
4184
6GT
-D2-
MBD
LE42
0-RP
50-B
LU/M
ULT
IRP
50
- 2"
3141
847
VCS
KRO
MSC
HRÖ
DER
DESI
GN
ATIO
N
ØCO
DEEx
port
/ EN
676
+ FG
DRDo
uble
sole
noid
valve
s VCS
Kro
msc
hröd
er a
nd
min
pre
ssur
e sw
itch
+ AC
S ga
s gov
erno
r & fi
lter
GT-K
2-VC
S125
-RP2
5-BL
U/M
ULT
IRP
25
- 1"
3142
024
GT-K
2-VC
S240
-RP4
0-BL
U/M
ULT
IRP
40
- 1"1
/231
4202
5GT
-K2-
VCS3
50-R
P50-
BLU
/MU
LTI
RP 5
0 - 2
"31
4186
2VG
D SI
EMEN
SDE
SIG
NAT
ION
ØCO
DE
Expo
rt /
EN67
6 +
FGDR
Doub
le g
as va
lves w
ith a
ctua
tors
and
regu
lato
r VG
D Si
emen
s and
min
pre
ssur
e sw
itch
+ AC
S ga
s filte
r.De
faul
t bla
nk sp
ring:
hea
d pr
essu
re 0
...22
mba
r
WAR
NIN
G:
from
BLU
300
0.1
- MUL
TICA
LOR
300.
1 -
MUL
TIFL
AM 3
00.1
chan
ge sp
ring
and
dam
ping
GT-S
2-VG
D20-
RP50
-BLU
/MU
LTI
Gas t
rain
sin
clude
ACT
UATO
RS
RP 5
0 - 2
"31
2386
0GT
-S2-
VGD4
0-DN
65-B
LU/M
ULT
IDN
65
- 2" 1
/231
2411
0GT
-S2-
VGD4
0-DN
80-B
LU/M
ULT
IDN
80
- 3"
3142
026
GT-S
2-VG
D40-
DN10
0-BL
U/M
ULT
IDN
100
- 4"
3141
869
GT-S
2-VG
D40-
DN10
0+VD
K-BL
U/M
ULT
IDN
100
- 4"
+ V
DK31
4187
1GT
-S2-
VGD4
0-DN
125-
BLU
/MU
LTI
DN 1
25 -
5"31
4266
6GT
-S2-
VGD4
0-DN
125+
VDK-
BLU
/MU
LTI
DN 1
25 -
5" +
VDK
3141
872
Yello
w se
tpoi
nt sp
ring
for S
KP25
...He
ad p
ress
ure:
15.
..120
mba
r31
4220
4Da
mpi
ng th
rott
le fo
r SKP
25...
3142
207
GAS
TRA
IN C
ON
NEC
TIO
N P
IPE
DESC
RIPT
ION
DESI
GN
ATIO
NCO
DE
WAR
NIN
G:
from
BLU
170
0.1
- MUL
TICA
LOR
170.
1 -
MUL
TIFL
AM 2
00.1
, in
orde
r to
fit th
e ga
s tra
in,
the
corr
espo
ndin
g co
nnec
tion
pipe
mus
t be
orde
red
(GTC
P siz
e an
d fitti
ng d
epen
d on
the
burn
er a
nd th
e
gas t
rain
sele
cted
)
GTCP
RP5
0-DN
65 p
latfo
rm 2
60GT
CP-R
P50-
DN65
-260
3141
842
GTCP
RP5
0 pl
atfor
m 2
80GT
CP-R
P50-
280
3142
074
GTCP
RP5
0 pl
atfor
m 2
80/3
20/3
80GT
CP-R
P50-
320/
380
3142
075
GTCP
RP5
0 BL
U 1
500
with
MB4
15-4
20GT
CP-R
P50-
BLU
1500
-MB4
15-4
2031
4207
6GT
CP R
P50
adap
tor f
or M
ULT
IFLA
MGT
CP-R
P50-
ADAP
TOR-
MU
LTIF
LAM
3143
080
GTCP
DN
65 p
latfo
rm 2
60/2
80/3
20
GTCP
-DN
65-2
60/2
80/3
2031
4219
7GT
CP D
N80
pla
tform
260
/280
/320
GTCP
-DN
80-2
60/2
80/3
2031
4206
9GT
CP D
N65
pla
tform
380
GTCP
-DN
65-3
8031
4207
1GT
CP D
N80
pla
tform
380
GTCP
-DN
80-3
8031
4207
0GT
CP re
duce
r fro
m D
N80
to D
N65
for M
ULT
IFLA
MGT
CP-R
EDU
CERD
N80
TODN
6531
4293
5GT
CP re
duce
r fro
m D
N10
0 to
DN
80 p
latfo
rm 3
20/3
80GT
CP-R
EDU
CERD
N10
0TO
DN80
3142
073
GTCP
redu
cer f
rom
DN
125
to D
N80
pla
tform
320
/380
GTCP
-RED
UCE
RDN
125T
ODN
8031
4310
5GT
CP D
N12
5 pl
atfor
m 3
80GT
CP-D
N12
5-38
031
4219
8GT
CP D
N65
pla
tform
630
GTCP
-DN
65-6
3031
4242
3GT
CP D
N80
pla
tform
630
/710
GTCP
-DN
80-6
30/7
1031
4242
4GT
CP D
N10
0 pl
atfor
m 6
30/7
10GT
CP-D
N10
0-63
0/71
031
4242
2GT
CP D
N12
5 pl
atfor
m 6
30/7
10Bo
th co
des n
eces
sary
fo
r gas
trai
n DN
125
GTCP
-DN
125-
630/
710
3142
422
GTCP
redu
cer f
rom
DN
125
to D
N10
0GT
CP-R
EDU
CERD
N12
5TO
DN10
031
4242
5
SPRI
NG
DAM
PIN
G TH
ROTT
LE
www.ecoflam-burners.com54
KIT
AND
ACCE
SSO
RIES
FOR
GAS
DESC
RIPT
ION
MAX
GAS
PRE
SSU
RECO
DE
GAS
GOVE
RNO
R
and
FILT
ER F
GDR
RP 1
5 - 1
/2" *
500
mba
r31
4251
9
RP 2
0 - 3
/4" *
500
mba
r31
4252
0
RP 2
5 - 1
" *50
0 m
bar
3142
521
RP 3
2 - 1
"1/4
*50
0 m
bar
3142
522
RP 4
0 - 1
"1/2
*50
0 m
bar
3142
523
RP 5
0 - 2
" *50
0 m
bar
3142
524
FS1B
RP
50 -
2"1
bar
3142
051
FS1B
DN
65
- 2"1
/21
bar
3141
983
FS1B
DN
80
- 3"
1 ba
r31
4253
8
FS1B
DN
100
- 4"
1 ba
ron
requ
est
FS1B
DN
125
- 5"
1 ba
ron
requ
est
* De
faul
t spr
ing
is ne
utra
l for
out
let p
ress
ure
rang
e 10
-30
mba
r
DESC
RIPT
ION
GAS
PRE
SSU
RE R
ANG
ECO
DE
SPRI
NG
fo
r GAS
GO
VERN
OR
and
FILT
ER F
GDR
Gree
n sp
ring
FGDR
15-
20-2
55÷
15 m
bar
3142
547
Neu
tral
sprin
g FG
DR 1
5-20
-25
10÷3
0 m
bar
3142
548
Viol
et sp
ring
FGDR
15-
20-2
525
÷80
mba
r31
4254
9
Brow
n sp
ring
FGDR
15-
20-2
570
÷160
mba
r31
4255
0
Blue
sprin
g FG
DR 1
5-20
-25
150÷
280
mba
r31
4255
1
Whi
te sp
ring
FGDR
15-
20-2
527
0÷35
0 m
bar
3142
552
Gree
n sp
ring
FGDR
32-
405÷
15 m
bar
3142
553
Neu
tral
sprin
g FG
DR 3
2-40
10÷2
5 m
bar
3142
554
Viol
et sp
ring
FGDR
32-
4020
÷70
mba
r31
4255
5
Brow
n sp
ring
FGDR
32-
4065
÷130
mba
r31
4255
6
Whi
te sp
ring
FGDR
32-
4012
0÷25
0 m
bar
3142
557
Blac
k sp
ring
FGDR
32-
4024
0÷35
0 m
bar
3142
558
Gree
n sp
ring
FGDR
50
5÷15
mba
r31
4255
9
Neu
tral
sprin
g FG
DR 5
010
÷35
mba
r31
4256
0
Viol
et sp
ring
FGDR
50
30÷8
0 m
bar
3142
561
Brow
n sp
ring
FGDR
50
70÷2
20 m
bar
3142
562
Blue
sprin
g FG
DR 5
0
21
0÷35
0 m
bar
3142
563
DESC
RIPT
ION
CODE
GAS
FILT
ERRP
15
- 1/2
"31
4195
7RP
20
- 3/4
"31
4204
5RP
25
- 1"
3142
046
RP 4
0 - 1
"1/2
3141
954
RP 5
0 - 2
"31
2138
4DN
65
- 2"1
/231
2411
1DN
80
- 3"
3142
088
DN 1
00 -
4"31
4220
5DN
125
- 5"
3142
206
DESC
RIPT
ION
CODE
ANTI
VIBR
ATIO
N
COU
PLIN
GRP
15
- 1/2
"31
2232
1RP
20
- 3/4
"31
2232
2RP
25
- 1"
3122
323
RP 3
2 - 1
"1/4
3122
324
RP 4
0 - 1
"1/2
3122
325
RP 5
0 - 2
"31
2232
6DN
65
- 2"1
/231
4206
0DN
80
- 3"
3122
328
DN 1
00 -
4"31
2232
9DN
125
- 5"
3142
061
DESC
RIPT
ION
CODE
MAN
UAL V
ALVE
RP 1
5 - 1
/2"
3142
000
RP 2
0 - 3
/4"
3142
254
RP 2
5 - 1
"31
2143
0RP
32
- 1"1
/431
4225
3RP
40
- 1"1
/231
4210
1RP
50
- 2"
3142
102
DN 6
5 - 2
"1/2
3142
062
DN 8
0 - 3
"31
4373
0DN
100
- 4"
3141
997
DN 1
25 -
5"31
4199
8
www.ecoflam-burners.com 55
KIT
AND
ACCE
SSO
RIES
FOR
GAS
DESC
RIPT
ION
DESI
GN
ATIO
NCO
DE
TIGH
TNES
S CO
NTR
OL
Kit ti
ghtn
ess c
ontr
ol V
PS50
4 fo
r VCS
gas
val
veKI
TTC-
VPS5
04-V
CS31
4192
9
Kit ti
ghtn
ess c
ontr
ol V
PS50
4 LP
G fo
r VCS
gas
val
veKI
TTC-
LPGV
PS50
4-VC
S31
4223
8
Kit ti
ghtn
ess c
ontr
ol V
PS50
4 fo
r MB
and
VGD6
5-80
val
veKI
TTC-
VPS5
04-M
B-VG
DDN
65-8
031
2230
3
Kit ti
ghtn
ess c
ontr
ol V
PS50
4 LP
G fo
r MB
and
VGD6
5-80
val
veKI
TTC-
LPGV
PS50
4-M
B-VG
DDN
65-8
031
4219
0
Kit ti
ghtn
ess c
ontr
ol V
PS50
4 fo
r VGD
2050
3 va
lve
KITT
C-VP
S504
-VGD
2050
331
2230
5
Kit ti
ghtn
ess c
ontr
ol V
PS50
4 LP
G fo
r VGD
2050
3 va
lve
KITT
C-LP
GVPS
504-
VGD2
0503
3142
688
Kit ti
ghtn
ess c
ontr
ol V
DK fo
r VGD
100-
125
KITT
C-VD
K200
3141
922
Kit ti
ghtn
ess c
ontr
ol L
DUKI
TTC-
LDU
1131
4231
4
Kit a
dapt
or fo
r kit
VPS
pilo
t gas
trai
n31
4275
4
DESI
GN
ATIO
NO
UTP
UT
RAN
GE
GAS
PRE
SSU
RECO
DE
MAX
IMU
M
GAS
PRES
SURE
SW
ITCH
KITP
RES5
010
0÷58
00 k
W2,
5÷50
mba
r31
4192
1
KITP
RES1
5070
00÷2
5000
kW
30÷1
50 m
bar
3142
033
DESC
RIPT
ION
GAS
PRE
SSU
RECO
DE
MAN
OM
ETER
+
PUSH
BU
TTO
NGa
s man
omet
er0…
60 m
bar 1
/2"
3142
056
Gas m
anom
eter
0…25
0 m
bar 1
/4"
3142
055
Gas m
anom
eter
0…10
00 m
bar 1
/4"
3142
054
Push
butt
on 1
/4"
Diam
eter
1/4
"31
4205
8
Push
butt
on 1
/2"
Diam
eter
1/2
"31
4205
7
DESI
GN
ATIO
NBU
RNER
CODE
KIT
LPG
/ KIT
GN
KITL
PG-M
AXGA
S40-
120
MAX
GAS
40-
120
3122
301
KITA
DAPT
OR-
MAX
GAS4
0-12
0M
AX G
AS 4
0-12
031
2229
9
KITL
PG-M
AXGA
S170
-250
MAX
GAS
170
-250
3122
302
KITA
DAPT
OR-
MAX
GAS1
70-2
50M
AX G
AS 1
70-2
5031
2230
0
KITL
PG-M
AXGA
S350
-500
MAX
GAS
350
-500
3142
431
KITL
PG-B
LU50
0.1
BLU
500
.131
2448
7
KITL
PG-B
LU70
0.1
BLU
700
.131
2448
8
KITL
PG-B
LU10
00.1
-150
0.1
BLU
100
0.1-
1200
.1-1
500.
131
2448
9
KITL
PG-B
LU17
00.1
-200
0.1
BLU
170
0.1-
2000
.131
4266
7
Oth
er m
odel
kit
on re
ques
t
www.ecoflam-burners.com56
KIT
AND
ACCE
SSO
RIES
FOR
OIL
DIAG
NOST
IC T
OO
L FO
R TH
ERM
OW
ATT
CONT
ROL
DESI
GN
ATIO
NDE
SCRI
PTIO
NCO
DEKI
T FO
R AU
TOM
ATIC
FU
EL S
WIT
CH G
AS/O
ILKI
T-AU
TOM
ATIC
FUEL
SWIT
CH-M
ULT
IDu
al fu
el b
urne
rs: M
ULT
ICAL
OR
and
MU
LTIF
LAM
3142
021
Stan
dard
vers
ion
runn
ing
on m
anua
l fue
l sel
ectio
n m
ode
and
with
the
auto
mati
c cha
ngeo
ver t
he sy
stem
chan
ge fu
el tr
igge
red
by a
gas
pre
ssur
e sw
itch
or b
y a
timer
DESI
GN
ATIO
NDE
SCRI
PTIO
NCO
DE
KIT
BIO
DIES
EL
KITB
IODI
ESEL
-PU
MP-
AS47
MAX
1...
30 a
nd M
AX P
25
AB H
S31
4191
7
KITB
IODI
ESEL
-PU
MP-
AT2/
AT3
MAX
P 1
2-15
AB
HS31
2410
3
DESI
GN
ATIO
NDE
SCRI
PTIO
NCO
DE
MAG
NET
IC +
SEL
FCLE
ANIN
G FI
LTER
KITO
IL50
KG-M
AGN
ETIC
+SEL
FCLE
ANIN
G-FI
LTER
MAX
FLAM
rang
e31
4209
2
KITO
IL25
0KG-
MAG
NET
IC+S
ELFC
LEAN
ING-
FILT
ERO
ILFL
AM ra
nge
3141
965
DESI
GN
ATIO
NDE
SCRI
PTIO
NCO
DE
KIT
WIE
LAN
D PL
UGS
KITW
P-M
AIO
R35-
300.
1PAB
MAI
OR
45 -
300.
131
4203
7
KITW
P-BL
U50
0.1-
2000
.1PA
BBL
U 5
00.1
- 20
00.1
(PAB
ver
sions
)31
4203
4KI
TWP-
BLU
/MU
LTIC
ALO
R-PR
/MD
BLU
- M
ULT
ICAL
OR
(PR
vers
ions
)31
4193
2
DESC
RIPT
ION
SEPA
RATE
PRE
-HEA
TER
UN
ITFr
om O
ILFLA
M 3
00.1
pre
-hea
ter c
an b
e su
pplie
d se
para
tely
with
ext
ra co
st
DESC
RIPT
ION
LIGH
T O
IL P
UM
PIN
G U
NIT
Sepa
rate
serv
ice ta
nks a
nd p
ump
units
DESC
RIPT
ION
HEAV
Y O
IL H
EATI
NG
AND
PUM
PIN
G U
NIT
“OIL
RING
” can
be
desig
n an
d de
liver
ed a
ssem
bled
on
skid
or o
ffere
d as
sing
le co
mpo
nent
DESC
RIPT
ION
SWIR
L SYS
TEM
Swirl
s for
bla
st tu
be th
at ca
n re
duce
flam
e le
nght
up
to 1
0-50
% d
epen
ding
on
fuel
, bac
kpre
ssur
e an
d sh
ape
of co
mbu
stion
cham
ber.
The
syst
em is
ava
ilabl
e fo
r diff
eren
t fue
l bur
ner b
last
tube
s
DESC
RIPT
ION
CODE
DIAG
NO
STIC
TO
OL
E-BC
U Di
agno
stic t
ool f
or 1
stag
e BC
U31
4293
1PC
inte
rface
for B
CU38
3301
8
www.ecoflam-burners.com 57
LOAD
CO
NTRO
LLER
AND
PRO
BES
DESC
RIPT
ION
DESI
GN
ATIO
NCO
DE
MO
DULA
TIN
G PI
D CO
NTR
OLL
ERKi
t for
pro
gres
sive
vers
ion
KITM
D-RW
F50
3143
713
DESC
RIPT
ION
DESI
GN
ATIO
NCO
DE
MAT
CHIN
G PR
OBE
FO
R FU
LL M
D VE
RSIO
NW
ater
pro
be u
p to
0÷1
30° С
PRO
BE-W
ATER
130C
3122
316
Stea
m p
robe
0÷2
bar
PRO
BE-S
TEAM
2BAR
3124
100
Stea
m p
robe
0÷4
bar
PRO
BE-S
TEAM
4BAR
3122
317
Stea
m p
robe
0÷1
0 ba
rPR
OBE
-STE
AM10
BAR
3122
318
Stea
m p
robe
0÷1
6 ba
rPR
OBE
-STE
AM16
BAR
3122
319
Stea
m p
robe
0÷4
0 ba
rPR
OBE
-STE
AM40
BAR
3122
320
Hot a
ir or
liqui
d pr
obe
up to
0÷4
50° С
PRO
BE-H
OTA
IR-L
IQU
ID45
0C31
2231
4
SILE
NCER
PLAT
FORM
GAS
LIG
HT O
ILHE
AVY
OIL
DUAL
FU
EL (G
AS/L
IGHT
OIL
)DU
AL F
UEL
(GAS
/HEA
VY O
IL)
KITS
IL-2
60BL
U 7
00.1
- 12
00.1
MAI
OR
45 -
120
OIL
FLAM
50.
1 - 1
20.1
MU
LTIC
ALO
R 45
- 14
0M
ULT
IFLA
M 5
0.1
- 120
.1
KITS
IL-2
80BL
U 1
500.
1 - 2
000.
1M
AIO
R 15
0.1
- 200
.1O
ILFL
AM 1
70.1
- 20
0.1
MU
LTIC
ALO
R 17
0.1
- 200
.1M
ULT
IFLA
M 1
70.1
- 20
0.1
KITS
IL-3
20BL
U 3
000.
1 - 4
000.
1M
AIO
R 30
0.1
- 400
.1O
ILFL
AM 3
00.1
- 40
0.1
MU
LTIC
ALO
R 30
0.1
- 400
.1M
ULT
IFLA
M 3
00.1
- 40
0.1
KITS
IL-3
80BL
U 5
000.
1 - 6
000.
1M
AIO
R 50
0.1
- 600
.1O
ILFL
AM 5
00.1
- 60
0.1
MU
LTIC
ALO
R 50
0.1
- 600
.1M
ULT
IFLA
M 5
00.1
- 60
0.1
KITS
IL-6
30BL
U 7
000.
1 - 1
2000
.1M
AIO
R 70
0.1
- 120
0.1
OIL
FLAM
700
.1 -
1200
.1M
ULT
ICAL
OR
700.
1 - 1
200.
1M
ULT
IFLA
M 7
00.1
- 12
00.1
KITS
IL-7
10BL
U 1
5000
.1 -
1800
0.1
MAI
OR
1500
.1 -
1800
.1O
ILFL
AM 1
500.
1 - 1
800.
1M
ULT
ICAL
OR
1500
.1 -
1800
.1M
ULT
IFLA
M 1
500.
1 - 1
800.
1DU
OBL
OCK
Sepa
rate
venti
lato
r sile
ncer
/ So
und
proo
f pla
tform
on
requ
est
PLAT
FORM
CODE
KITS
IL-2
6031
4191
1
KITS
IL-2
8031
2229
8KI
TSIL
-320
3141
913
KITS
IL-3
8031
4191
4KI
TSIL
-630
3142
276
KITS
IL-7
1031
4266
8
Opti
on a
vaila
ble
star
ting
from
pla
tform
260
www.ecoflam-burners.com58
BURNER SELECTION FORM
SECTION 1 - GENERAL INFORMATION
CUSTOMER - COUNTRY
REFERENCE SALES PERSON
REQUEST DATE
INSTALLATION LOCATION
SEGMENT heating bakery projectsheating OEM dryers other industry
SECTION 2 - BOILER INFORMATION
BOILER TYPE
three pass boilerreverse flame boilerwater tube boilerdiathermic boiler
APPLICATION TYPEincineratordryer / hot air generatoroven
HEAT TRANSFER MEDIUM
steam (saturated)STEAM
Steam capacity [TPH]
steam (superheated) Required steam pressure bar
hot water Steam temperature [°C]
salt / oilOTHER
Medium temperature [°C]
others Medium inlet temperature [°C]
POWER REQUIREMENT
Boiler Output [kW]
1 kW = 860 kcal/h
BOILER LOCATION outdoorBoiler Input [kW] indoorBoiler efficiency [%] HEIGHT ABOVE SEA LEVEL [m]
Burner power [kW]
FURNACE CHAMBER DATA
Backpressure [mbar] DIMENSIONS [mm]Inner diameter
Furnace position horizontal Lengthtop-down Return chamber lengthbottom-up Length
Height
Required blast tube Lenght
min [mm] Widthmax [mm]
ELECTRICAL SUPPLY DATA
Voltage single phase 110 V 220 V 230 V 240 VVoltage three phase 220 V 380 V 400 V 415 V 440 V 460 V 480 VFrequency 50 Hz 60 HzRequired IP factor IP40 IP54 other:
SECTION 3 - FUEL INFORMATION
LIGHT OIL - HEAVY OIL GAS / LPG BIOGAS-TOWNGAS (Max H2S<0,1%)
Type: …………………………............... Type: ……………………….............. Type: ………………………………………..................
Lower calorific value [kcal/kg] Lower calorific value [kcal/m3] Lower calorific value [kcal/m3]
Viscosity at 50°C [°E] Supply pressure [mbar] Supply pressure [mbar]
Required flowrate [kg/h] Required flowrate [m3/h] Required flowrate [m3/h]
Boiler brandBoiler modelBoiler manuf. year
www.ecoflam-burners.com 59
SECTION 4 - BURNER
Other requirements: specify
ELECTRICALCONFIGURATION
standard electrical panelloosen form with derivative panelseparate switch cabinet
OPTIONS FORELECTRONIC VERSION
inverter (modulating electronic only)O2 trim (modulating electronic only)CO trim (modulating electronic only)
CONTROL TYPE
1 stage2 stages2 stage progressive mechanicalmodulating mechanical with PIDmodulating electronic
FUEL SUPPLYsingle fuel FUEL 1: Automatic fuel
changeovertwo fuels FUEL 2:three fuels FUEL 3:
EMISSIONS LEVEL NOx: Gas: <120 mg/kWh <80 mg/kWh Light Oil: <250 mg/kWh <185 mg/kWh <120 mg/kWh
EN676Class 2 Class 3
EN267Class 1 Class 2 Class 3
CO: 0...100 mg/kWh 0...110 mg/kWh 0...60 mg/kWh
NOMINAL TURNDOWN RATIO
mechanical: 1:3 electronic with inverter: 1:8electronic: 1:6 electronic with inverter: 1:10
BURNER POWER refer to the field "burner power" in the section "power requirement"
BURNER TYPE Monoblock
Combustion air temperature [°C] (Max 200°C)
Duoblock Heat exchanger pressure losses [mbar]
Current fan (if existing): flowrate: [m3/h]pressure: [mbar]
SECTION 5 - GAS TRAIN CONFIGURATION
Gas governor and filter Tightness control Maximum pressure switch
Gas train type
Dungs MultiBloc FGDR Max 500 mbar VPS KITPRES50Siemens VGD FS1B Max 1 bar VDK up to 6 MWKromschröder VCS ST4B Max 4 bar LDU KITPRES150Honeywell Filter Max 1 bar Electronic up to 25 MW
Other requirements: specify
NOTES - ADDITIONAL INFORMATION
Version 1.5 - 15/07/2014ECOFLAM Bruciatori S.p.A. reserves the right to make any adjustments, without prior notice, which is considered necessary or useful to its products, without affecting their main features.
HEAD OFFICE:Via Roma, 6431023 Resana (TV)
Tel.: +39 0423 719500Fax: +39 0423 719580Web: www.ecoflam-burners.comEmail: [email protected]
REGISTERED OFFICE:Viale A. Merloni, 4560044 Fabriano (AN)
Company subject to the direction and coordination of Ariston Thermo SpA. - Via A. Merloni, 45 - 60044 Fabriano (AN) - CF 01026940427