Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
T H E S I E M O N . C O M P A N Y4•0
Wor
k Ar
eaSh
ield
edPr
oduc
tsM
odul
arPa
tchi
ng
Rack
s an
dCa
ble
Man
agem
ent
Patc
h Co
rds,
Plug
s an
dCa
ble
S210
Prod
ucts
S110
Prod
ucts
S66
Prod
ucts
Prot
ection
Tool
san
dTe
ster
s
Stan
dard
sOve
rvie
wAp
plic
atio
nGui
deIn
stal
lation
Prac
tice
sGlo
ssar
yIn
dex
Fibe
rPr
oduc
ts
HD®
PANELS(pages 4.2 – 4.5)
MAX™
PANELS(pages 4.6 – 4.7)
CT®
PANELS(pages 4.8 – 4.9)
Product High density, high performance Multimedia MultimediaApplications modular patching for UTP (used in conjunction (used in conjunction
with MAX™ modules with CT® couplersat work area) at work area)
Connectors Integral MAX™ Modules CT® Couplers
Media Types UTP UTP, Coax, Fiber, Video UTP, Coax, Fiber, Video
Category
Termination S310™, S110®, 25-pair S310™, SC, ST, FC, MT-RJ, LC, S310™, S110®, SC, ST, FC,Types BNC, F-type, RCA BNC, MT-RJ, LC,
F-type, RCA, 25-Pair
Capacity 12-Port on 89D Bracket, 12-Port on 89D Bracket, 16, 24, 28, 32, 48, 64, 96(Ports) 16, 24, 48, 96 16, 24, 48
Included Rear Cable Management Bar, Rear Cable Management Bar, Mounting HardwareAccessories Icon/Label Holders, Designation Labels,
Designation Labels, Cable Ties, Mounting HardwareMounting Hardware
MODULAR PATCHING
04 00-11 12/15/00 5:16 PM Page a2
T H E S I E M O N . C O M P A N Y4•1
Wor
k Ar
eaSh
ield
edPr
oduc
tsM
odul
arPa
tchi
ng
Rack
s an
dCa
ble
Man
agem
ent
Patc
h Co
rds,
Plug
s an
dCa
ble
S210
Prod
ucts
S110
Prod
ucts
S66
Prod
ucts
Prot
ection
Tool
san
dTe
ster
s
Stan
dard
sOve
rvie
wAp
plic
atio
nGui
deIn
stal
lation
Prac
tice
sGlo
ssar
yIn
dex
Fibe
rPr
oduc
ts
The modular patching manu-
facturing area is a true
testimonial to The Siemon
Company’s creativity and
ingenuity in product design
and manufacturing. I have
been with The Siemon
Company for over seven years
and have seen many advances
in manufacturing technology and new generations of modular
patching products. The HD® patch panel products are a great
example of our company’s evolution.
First we apply the Siemon name and product designation
labels to the HD® patch panels using a very precise silk screen
or laser printing technology. We take great pride in our
company name and meticulously inspect the appearance of
each panel.
The manufacturing of sub-assemblies used in the HD® panels
was at one time performed by three operators. Now they are
not only produced on automated equipment, but are also 100%
inspected during the process. We don’t stop there; the sub-
assemblies are also manually inspected. Each HD® panel is then
hand assembled and inspected again before it is packaged for
shipment.
Our design engineers worked hard to improve the original
HD® patch panel, resulting in our HD6™ product, the world’s
first category 6 patch panel. The performance of the HD6™
results from the combination of the advanced balancing and
pair isolation techniques used in the S310™ punch down block,
circuit board and modular jack. Our engineers also took this
opportunity to improve the aesthetics of the HD6™ by
incorporating a screw-free front.
Advanced manufacturing, resourceful engineering, in-depth
quality inspection, and skilled operators unite to make our HD®
patch panels unparalleled in the industry.
SECTION CONTENTSHD6™ Patch Panels . . . . . . . . . . . . . . . . . . . 4.2 – 4.3
12-Port HD™ Mounted on S89D Bracket . . . . . . . . . 4.3
HD6™ Optional Accessories . . . . . . . . . . . . . . . . . . 4.3
HD5® Patch Panels . . . . . . . . . . . . . . . . . . . 4.4 – 4.5
12-Port HD5® Mounted on S89D Bracket. . . . . . . . . 4.5
HD5® Quick-Patch™ Panel . . . . . . . . . . . . . . . . . . . 4.5
MAX™ Patch Panels . . . . . . . . . . . . . . . . . . . 4.6 – 4.7
12-Port MAX™ Mounted on S89D Bracket . . . . . . . . 4.7
MAX™ Optional Accessories . . . . . . . . . . . . . . . . . . 4.7
CT® Patch Panels . . . . . . . . . . . . . . . . . . . . 4.8 – 4.9
Oversized CT® Panels . . . . . . . . . . . . . . . . . . . . . 4.10
CT-DK Designation Kit. . . . . . . . . . . . . . . . . . . . 4.10
Grounding Brackets . . . . . . . . . . . . . . . . . . . . . 4.10
Modular Patch Blocks® . . . . . . . . . . . . . . . . . . . . 4.11
Pre-wired 25-Pair CT® Panels . . . . . . . . . . . . . . . 4.11
Blank Filler Panels . . . . . . . . . . . . . . . . . . . . . . 4.11
SIEMON MANUFACTURING ON MODULAR PATCHING
04 00-11 12/15/00 5:16 PM Page a3
HD6™ PATCH PANELS
T H E S I E M O N . C O M P A N Y4•2
Wor
k Ar
eaSh
ield
edPr
oduc
tsM
odul
arPa
tchi
ng
Rack
s an
dCa
ble
Man
agem
ent
Patc
h Co
rds,
Plug
s an
dCa
ble
S210
Prod
ucts
S110
Prod
ucts
S66
Prod
ucts
Prot
ection
Tool
san
dTe
ster
s
Stan
dard
sOve
rvie
wAp
plic
atio
nGui
deIn
stal
lation
Prac
tice
sGlo
ssar
yIn
dex
Fibe
rPr
oduc
ts
CIRCUIT PROTECTIONRear metal enclosure protectsprinted circuitry.
PYRAMID™ WIRE ENTRYSYSTEMPyramid™ wire entry system onS310™ blocks separates pairedconductors when lacing cables to reduce installation time.
HD6™ PATCH PANEL HIGHLIGHTSA breakthrough in patch panel performance. The industry’s first patch panel that
exceeds category 6* connecting hardware specifications for all pair
combinations up to 250 MHz. Get revolutionary performance and all the same
user-friendly termination, labeling, and cable management features available
with Siemon’s popular HD5® patch panel.
TECHNICAL TIP!HD6™ Patch Panels feature universal wiringfor both T568A and T568B applications.
Use of the MC6™ modular cords with patentedyellow KeyBar™ is required to unlock the
performance of Siemon category 6* products.See pages 6.2 – 6.3.
MODULAR OUTLETS ARE FCC CFR47 PART 68 SUBPART F AND IEC603.7 COMPLIANT AND HAVE 50MICROINCH GOLD PLATED CONTACTS
FRONT SURFACE IS UNINTERRUPTED
BY SCREW HEADS FOR A CLEAN
APPEARANCE
ICON LABEL HOLDERS AND
DESIGNATION LABELS INCLUDED
BLACK ANODIZED PANELS CAN BE
MOUNTED DIRECTLY TO AN EIASTANDARD 19 INCH RELAY RACK
OR CABINET
BUILT-IN CABLE MANAGERIncludes rear cable manager toproperly guide cables to point oftermination.
*At the time of this catalog printing,category 6/class E specificationswere under development by TIA/EIAand ISO/IEC.
04 00-11 12/15/00 5:16 PM Page 2
T H E S I E M O N . C O M P A N Y4•3
Wor
k Ar
eaSh
ield
edPr
oduc
tsM
odul
arPa
tchi
ng
Rack
s an
dCa
ble
Man
agem
ent
Patc
h Co
rds,
Plug
s an
dCa
ble
S210
Prod
ucts
S110
Prod
ucts
S66
Prod
ucts
Prot
ection
Tool
san
dTe
ster
s
Stan
dard
sOve
rvie
wAp
plic
atio
nGui
deIn
stal
lation
Prac
tice
sGlo
ssar
yIn
dex
Fibe
rPr
oduc
ts
Use (X) to specify color: 2 = white, 3 = red, 4 = gray, 5 = yellow, 6 = blue, 7 = green, 8 = violet, 9 = orange
HD5-LBL-ID. . . . . . . . . . . . . . . . . . . . . . . .
Adhesive designation strips in a package oftwenty for 24-, 48-, or 96-port panels
HD5-LBL-480 . . . . . . . . . . . . . . . . . . . . . .
Adhesive strips for sequentially numberingpanel ports 1 through 480 for 24-, 48-, or96-port panels
HD5-LBL-(X) . . . . . . . . . . . . . . . . . . . . . . .
Removable designation strips in a packageof fifty for all versions of HD® panels
HD5-LBL6-(X) . . . . . . . . . . . . . . . . . . . . . .
Removable designation strips in a packageof eight for 24-, 48-, or 96-port panels
HD5-LBL8-(X) . . . . . . . . . . . . . . . . . . . . . .
Removable designation strips in a packageof four for 16-port panels
COLORED ICONS PAGE 2.7
HD5-ICON8 . . . . . . . . . . . . . . . . . . . . .
Adhesive-backed strips in a packageof 4 for color-coding and port designation for 16-port panels (icons not included)
HD5-ICON8-LBL . . . . . . . . . . . . . . . . . .
20 sheets of labels for HD5-ICON8 for laser printing (8 labels per sheet)*
HD5-ICON6 . . . . . . . . . . . . . . . . . . . . .
Adhesive-backed strips in a packageof 8 for color-coding and port designation for 24-, 48-, or 96-port panels (icons not included)
HD5-ICON6-LBL . . . . . . . . . . . . . . . . . .
10 sheets of labels for HD5-ICON6 for laser printing (16 labels per sheet)*
PART # DESCRIPTION
HD-RWM . . . . . . . . . . . . . . . . . Rear cable management bracket for HD® patch panels
*Visit our web site or contact our technical support department for labeling software.
OPTIONAL ACCESSORIES
HD6™ PATCH PANELS
Panels include rear cable manager, icon label holders, designation labels, cableties, and mounting hardware
Add “B” for bulk project pack of 5 panels (rear cable managers and icon labelholders not included but can be ordered separately). Contact Customer Service for other panel sizes.Note: 1 RMS = 44.5mm (1.75 in.)
PART # DESCRIPTION RMSHD6-16 . . . . . . . . . . . . . . 16-port panel, T568A/B wiring . . . . . . . . . . . . . . 1
PART # DESCRIPTION RMSHD6-96 . . . . . . . . . . . . . . 96-port panel, T568A/B wiring. . . . . . . . . . . . . . . 4
HD6-24 . . . . . . . . . . . . . 24-port panel, T568A/B wiring . . . . . . . . . . . . . . 1
HD6-48 . . . . . . . . . . . . . 48-port panel, T568A/B wiring . . . . . . . . . . . . . . 2
MC6™ MODULAR CORDS PAGES 6.2 – 6.3
�
12-PORT HD6™ MOUNTED ON S89D BRACKET The HD6-89 offers an economical solution for small applications and is ideal for retrofitting S66™
punch down blocks to a high performance modular design.
PART # DESCRIPTION
HD6-89D-12 . . . . . . . . . . . . . . . 12-port HD6™ panel, T568A/B wiring, mounted on S89D bracket
height: 254.0mm (10.0 in), width: 85.9mm (3.38 in),depth: 60.2mm (2.37 in)
04 00-11 12/15/00 5:16 PM Page 3
T H E S I E M O N . C O M P A N Y4•4
Wor
k Ar
eaSh
ield
edPr
oduc
tsM
odul
arPa
tchi
ng
Rack
s an
dCa
ble
Man
agem
ent
Patc
h Co
rds,
Plug
s an
dCa
ble
S210
Prod
ucts
S110
Prod
ucts
S66
Prod
ucts
Prot
ection
Tool
san
dTe
ster
s
Stan
dard
sOve
rvie
wAp
plic
atio
nGui
deIn
stal
lation
Prac
tice
sGlo
ssar
yIn
dex
Fibe
rPr
oduc
ts
HD5® PATCH PANEL HIGHLIGHTSHD5® series patch panels offer the most robust patching solution in the
industry. HD5® panels feature universal T568A/B wiring and exceed category
5e requirements with component and channel performance to 160MHz. Panels
include a rear cable manager, icon/label holders, designation labels, cable
ties, and mounting hardware.
EASY TERMINATIONCompliant pin technology allowsthe use of Siemon’s multi-pairimpact tool to minimizetermination time (see page 11.6).
REAR METAL ENCLOSUREThe rear metal enclosure protectsthe printed circuitry.
CABLE MANAGEMENTRear cable manager and cable-tieeyelets properly guide cables toand from the rear of the panel.
HD5® PATCH PANELS
MC5 MODULAR CORDS PAGES 6.4 – 6.5, PANEL ACCESS HINGE PAGE 5.8, CABLE MANAGERS PAGE 5.12
The most economical way to order HD5® panels
is in bulk project pack
MODULAR OUTLETS ARE
FCC CFR 47 PART 68SUBPART F AND IEC603.7 COMPLIANT AND
HAVE 50 MICROINCH
GOLD PLATED CONTACTS
• S110® TERMINATION BLOCKS ON
THE REAR ARE COMPATIBLE WITH
S110® PATCH PLUGS (NOT SHOWN)
BLACK ANODIZED
PANELS CAN BE
MOUNTED DIRECTLY
TO AN EIA STANDARD
19 INCH RELAY RACK
OR CABINET
WRITE-ON AREA PROVIDED
FOR CIRCUIT DESIGNATION
ICON AND LABEL HOLDER KITS
(INCLUDED) COLOR CODE AND LABEL
INDIVIDUAL PORTS
FRONT SURFACE IS
UNINTERRUPTED BY
SCREW HEADS FOR A
CLEAN APPEARANCE
��160MHz
HD5® panels provide component and
channel performance to 160MHz.
�
04 00-11 12/15/00 5:16 PM Page 4
T H E S I E M O N . C O M P A N Y4•5
Wor
k Ar
eaSh
ield
edPr
oduc
tsM
odul
arPa
tchi
ng
Rack
s an
dCa
ble
Man
agem
ent
Patc
h Co
rds,
Plug
s an
dCa
ble
S210
Prod
ucts
S110
Prod
ucts
S66
Prod
ucts
Prot
ection
Tool
san
dTe
ster
s
Stan
dard
sOve
rvie
wAp
plic
atio
nGui
deIn
stal
lation
Prac
tice
sGlo
ssar
yIn
dex
Fibe
rPr
oduc
ts
12-PORT HD5® MOUNTED ON S89D BRACKET
The HD5-89 offers an economical solution for small applications and is idealfor retrofitting S66™ punch down blocks to a modular design. Featuresuniversal T568A/B wiring.
PART # DESCRIPTION
HD5-89D-12 . . . . . . . . . . . . . . . 12-port HD5® panel mounted on S89D bracketheight: 254.0mm (10.0 in.), width: 85.9mm (3.38 in.), depth: 47.8mm (1.88 in.)
HD5® QUICK-PATCH™ PANEL
Siemon’s new HD5® Quick-Patch™ panel provides a quick and easy category5 channel patching solution for 10/100BASE-T hubs with 25-pairconnectors. The HD5® Quick-Patch™ Panel incorporates many user-friendlyfeatures and benefits, including rear connectors that are staggered to enableeasy routing of 25-pair cable to the connection point and a rear metalenclosure that protects printed circuitry. The black anodized panel can bemounted directly to a standard 19 inch rack or cabinet with the mountinghardware included. Icon/label holders and designation labels (included).
PART # DESCRIPTION
HD5-QP-48 . . . . . . . . . . . . . . . . 48-port 10/100BASE-T panel (Active pins 1, 2, 3 & 6only), four 25-pair connectors (female), 2 RMS
HD5® PATCH PANELS
ACCESSORIES PAGE 4.3
Panels include rear cable manager, icon/label holders, designation labels, cableties, and mounting hardware
Add “B” for bulk project pack of 5 panels (rear cable managers and icon labelholders not included but can be ordered separately). Contact Customer Service for other panel sizes.Note: 1 RMS = 44.5mm (1.75 in.)
PART # DESCRIPTION RMS PART # DESCRIPTION RMSHD5-96 . . . . . . . . . . . . . . . . . . . . 96-port panel . . . . . . . . . . . . . . . . . . . . . 4HD5-24 . . . . . . . . . . . . . . . . . . . . 24-port panel . . . . . . . . . . . . . . . . . . . . . 1
HD5-48 . . . . . . . . . . . . . . . . . . . . 48-port panel . . . . . . . . . . . . . . . . . . . . . 2
ACCESSORIES PAGE 4.3
Panels include icon/label holders, designation labels, and mounting hardwareNote: 1 RMS = 44.5mm (1.75 in.)
�
compatible
04 00-11 12/15/00 5:16 PM Page 5
T H E S I E M O N . C O M P A N Y4•6
Wor
k Ar
eaSh
ield
edPr
oduc
tsM
odul
arPa
tchi
ng
Rack
s an
dCa
ble
Man
agem
ent
Patc
h Co
rds,
Plug
s an
dCa
ble
S210
Prod
ucts
S110
Prod
ucts
S66
Prod
ucts
Prot
ection
Tool
san
dTe
ster
s
Stan
dard
sOve
rvie
wAp
plic
atio
nGui
deIn
stal
lation
Prac
tice
sGlo
ssar
yIn
dex
Fibe
rPr
oduc
ts
MAX™ PATCH PANEL HIGHLIGHTSThe 16-, 24-, and 48-port MAX™ patch panels provide a flexible, high density
termination solution for the telecommunications room. Using the full line of
MAX™ modules (available separately), the panel can be configured for a variety
of multimedia applications. Blank modules can be used to reserve ports for
future capacity.
MODULARITYIndividual modules snap into placefrom front or rear of panel foradded installation flexibility.
PORT IDENTIFICATIONRemovable designation labels canbe laser printed and enable propercircuit identification for each port.
CABLE MANAGEMENTRear cable management barincluded for routing horizontalcables to terminations.
MAX™ PATCH PANELS
TECHNICAL TIP!Use flat MAX™ modules for patch panelapplications.
MAX™ MODULES PAGES 2.14 – 2.19, FIBER MANAGEMENT TRAY PAGE 1.11
BOLD PORT NUMBERING
ENABLES QUICK AND READY
IDENTIFICATION OF OUTLETSPANELS CAN BE MOUNTED
DIRECTLY ON STANDARD 19 INCH
RELAY RACK OR CABINET
LIGHTWEIGHT, HIGH STRENGTH
BRUSHED ALUMINUM WITH BLACK
PROTECTIVE FINISH
COMBINES MODULAR DESIGN
WITH HIGH DENSITY FOR
ULTIMATE FLEXIBILITY
MULTIMEDIA CAPABILITY - MIX
AND MATCH MANY DIFFERENT
TYPE OF CONNECTORS
04 00-11 12/15/00 5:16 PM Page 6
T H E S I E M O N . C O M P A N Y4•7
Wor
k Ar
eaSh
ield
edPr
oduc
tsM
odul
arPa
tchi
ng
Rack
s an
dCa
ble
Man
agem
ent
Patc
h Co
rds,
Plug
s an
dCa
ble
S210
Prod
ucts
S110
Prod
ucts
S66
Prod
ucts
Prot
ection
Tool
san
dTe
ster
s
Stan
dard
sOve
rvie
wAp
plic
atio
nGui
deIn
stal
lation
Prac
tice
sGlo
ssar
yIn
dex
Fibe
rPr
oduc
ts
MAX™ PATCH PANELS
PART # DESCRIPTION RMSMX-PNL-16. . . . . . . . . . . . . . . . 16-port panel . . . . . . . . . . . . . . . . . 1
12-PORT MAX™ PANEL MOUNTED ON S89D BRACKET
The MAX™ S89D offers an economical solution for smaller applications while allowing for a range of different media usingthe full line of MAX™ modules (not included).
PART # DESCRIPTION
MX-89D-12. . . . . . . . . . . . . . . . 12-port MAX™ panel mounted on an 89D bracket
height: 254.0mm (10.0 in.), width: 85.9mm (3.38 in.), depth: 47.8mm (1.88 in.)
MX-PNL-24. . . . . . . . . . . . . . . . 24-port panel . . . . . . . . . . . . . . . . . 1
MX-PNL-48. . . . . . . . . . . . . . . . 48-port panel . . . . . . . . . . . . . . . . . 2
OPTIONAL ACCESSORIES
*Visit our web site or contact our Technical Support Department for labeling software.
MX-PNL-LBL4* . . . . . . . . . . . . .
10 sheets of laser printable labels for 16-port MAX™ panel
MX-PNL-LBL6* . . . . . . . . . . . . .
10 sheets of laser printable labels for 24- and 48-port MAX™ panels
Panels include rear cable manager, designation labels, cable ties, and mounting hardware.MAX™ Panels not compatible with shielded MAX™ modules. Use the Tera™-MAX™ panel (see page 3.4).Note: 1 RMS = 44.5mm (1.75 in.)
04 00-11 12/15/00 5:16 PM Page 7
T H E S I E M O N . C O M P A N Y4•8
Wor
k Ar
eaSh
ield
edPr
oduc
tsM
odul
arPa
tchi
ng
Rack
s an
dCa
ble
Man
agem
ent
Patc
h Co
rds,
Plug
s an
dCa
ble
S210
Prod
ucts
S110
Prod
ucts
S66
Prod
ucts
Prot
ection
Tool
san
dTe
ster
s
Stan
dard
sOve
rvie
wAp
plic
atio
nGui
deIn
stal
lation
Prac
tice
sGlo
ssar
yIn
dex
Fibe
rPr
oduc
ts
CT® PATCH PANEL HIGHLIGHTSCT® panels complement our CT® work area products and offer a feature-rich
and flexible patching solution. CT® couplers are ordered separately and
quickly snap into black anodized patch panels. This easy snap-in capability
lets you custom configure panels to suit your particular application. Low cost
blank couplers are available to fill unused ports, and can be replaced with
active couplers when the need arises.
MULTIMEDIA CAPABILITYFor optimum flexibility, the CT®
Panel accepts a wide variety ofCT® couplers, including UTP, fiber,and coax.
REAR LABELING SYSTEMCT® Panels are labeled on rear toassist in cable identification whileterminating.
REAR CABLE MANAGEMENTSiemon offers a wide range ofrear cable management productsto encompass a wide range ofrack sizes and cable routingmethods — see page 5.11 formore information.
CT® PATCH PANELS
CT® COUPLERS PAGES 2.2 – 2.7, FIBER MANAGEMENT TRAY PAGE 1.11
TECHNICAL TIP!Flat couplers are recommended for patchpanel applications.
MOUNTING SLOTS ARE
ANSI/EIA-310 COMPATIBLE
BLACK ANODIZED PANELS CAN BE
MOUNTED DIRECTLY TO AN EIA STANDARD
19 INCH RELAY RACK OR CABINET
CUTOUTS ALLOW TERMINATED
COUPLERS TO PASS THROUGH
PANELS FROM FRONT TO BACK
OR BACK TO FRONT
• OPTIONAL FIBER MANAGEMENT TRAY
IS AVAILABLE FOR NEW OR RETROFIT
APPLICATIONS (SEE PAGE 1.11)
04 00-11 12/15/00 5:17 PM Page 8
T H E S I E M O N . C O M P A N Y4•9
Wor
k Ar
eaSh
ield
edPr
oduc
tsM
odul
arPa
tchi
ng
Rack
s an
dCa
ble
Man
agem
ent
Patc
h Co
rds,
Plug
s an
dCa
ble
S210
Prod
ucts
S110
Prod
ucts
S66
Prod
ucts
Prot
ection
Tool
san
dTe
ster
s
Stan
dard
sOve
rvie
wAp
plic
atio
nGui
deIn
stal
lation
Prac
tice
sGlo
ssar
yIn
dex
Fibe
rPr
oduc
ts
CT® PATCH PANELS MAXIMUM
QUANTITY OF
PART # DESCRIPTION* RMS CT® COUPLERS
CT-PNL-16 . . . . . . . 16-port panel . . . . . . . 1 . . . . . . . . . . . 8
CT-PNL-24 . . . . . . . 24-port panel . . . . . . . 2 . . . . . . . . . . . 12
CT-PNL-28 . . . . . . . 28-port panel . . . . . . . 2 . . . . . . . . . . . 14
CT-PNL-32 . . . . . . . 32-port panel . . . . . . . 2 . . . . . . . . . . . 16
CT-PNL-48 . . . . . . . 48-port panel . . . . . . . 3 . . . . . . . . . . . 24
CT-PNL-64 . . . . . . . 64-port panel . . . . . . . 4 . . . . . . . . . . . 32
CT-PNL-96 . . . . . . . 96-port panel . . . . . . . 6 . . . . . . . . . . . 48
*Number of ports when configured with CT® two port couplersNote: 1 RMS = 44.5mm (1.75 in.)
04 00-11 12/15/00 5:17 PM Page 9
T H E S I E M O N . C O M P A N Y4•10
Wor
k Ar
eaSh
ield
edPr
oduc
tsM
odul
arPa
tchi
ng
Rack
s an
dCa
ble
Man
agem
ent
Patc
h Co
rds,
Plug
s an
dCa
ble
S210
Prod
ucts
S110
Prod
ucts
S66
Prod
ucts
Prot
ection
Tool
san
dTe
ster
s
Stan
dard
sOve
rvie
wAp
plic
atio
nGui
deIn
stal
lation
Prac
tice
sGlo
ssar
yIn
dex
Fibe
rPr
oduc
ts
OVERSIZED CT® PANELS
Oversized CT® panels are available for applications that require additional labeling space. They provide the same flexibility as our standard CT® panelsand feature a write-on designation surface above each coupler opening that can also be used as a space for adhering your own label. We also offeradhesive-backed label holders with replaceable write-on labels that mount above the entire row of CT® couplers.
*Number of ports when configured with CT® two port couplersNote: 1 RMS = 44.5mm (1.75 in.)
MAXIMUM
QUANTITY OF
PART # DESCRIPTION* RMS CT® COUPLERS
CT-PNL-64-ID . . . . . 64-port panel . . . . . . . . . . 5 . . . . . . . . . . . . . 32
MAXIMUM
QUANTITY OF
PART # DESCRIPTION* RMS CT® COUPLERS
CT-PNL-16-ID . . . . . 16-port panel . . . . . . . . . . 2 . . . . . . . . . . . . . . 8
CT-PNL-48-ID . . . . . 48-port panel . . . . . . . . . . 4 . . . . . . . . . . . . . 24
CT-PNL-24-ID . . . . . 24-port panel . . . . . . . . . . 3 . . . . . . . . . . . . . 12
CT-PNL-32-ID . . . . . 32-port panel . . . . . . . . . . 3 . . . . . . . . . . . . . 16
CT-PNL-96-ID . . . . . 96-port panel . . . . . . . . . . 7 . . . . . . . . . . . . . 48
Peel-off adhesive strip
SCREENED CT® 6 COUPLERS PAGE 3.5,SCREENED CT® 5E COUPLERS PAGE 3.6
GROUNDING BRACKETS
Our grounding brackets provide an anchor point and a grounding point for shielded (SSTP) orscreened (ScTP) cables being routed to the back of CT® patch panels. They are mounted usingthe same screws that hold the patch panel to the rack using the hex nuts provided.
PART # DESCRIPTION
SCTP-GRD-1RMS . . . . . . . . . . Provides cable management, sixteen 102mm (4 in.) jumper cables and one grounding lug for ScTP applications
SCTP-GRD-JMPR . . . . . . . . . . . Sixteen 102mm (4 in.) jumper cables
CT-DK DESIGNATION KIT
The CT-DK designation kit is a plastic, self-adhesive designation label holder with paper insertsdesigned for use with our ID series of oversized CT® panels. Each kit comes with six label holders andsix paper inserts.
PART # DESCRIPTION
CT-DK. . . . . . . . . . . . . . . . . . . . Bag of 6 adhesive backed, clear plastic holders with paper designation strips
04 00-11 12/15/00 5:17 PM Page 10
T H E S I E M O N . C O M P A N Y4•11
Wor
k Ar
eaSh
ield
edPr
oduc
tsM
odul
arPa
tchi
ng
Rack
s an
dCa
ble
Man
agem
ent
Patc
h Co
rds,
Plug
s an
dCa
ble
S210
Prod
ucts
S110
Prod
ucts
S66
Prod
ucts
Prot
ection
Tool
san
dTe
ster
s
Stan
dard
sOve
rvie
wAp
plic
atio
nGui
deIn
stal
lation
Prac
tice
sGlo
ssar
yIn
dex
Fibe
rPr
oduc
ts
MODULAR PATCH BLOCKS®
Our economical Modular Patch Blocks® provide a convenient 24-port modular cross-connect field for equipmentwith 25-pair female connector input. They are excellent for use with 10BASE-T, voice, broadcast, or alarm systems.The blocks fit a standard 66M block footprint for backboard or rack mounting applications.
PART # DESCRIPTION
SPB-V1 . . . . . . . . . . . . . . . . . . . One, 25-pair connector wired to 24, 1-pair 6-position modular jacks,USOC wiring. Black universal holddown
SPB-V2 . . . . . . . . . . . . . . . . . . Two, 25-pair connectors, each wired to 24, 2-pair 6-position modular jacks,USOC wiring. One black, one blue universal holddown
SPB-V3 . . . . . . . . . . . . . . . . . . . Three, 25-pair connectors, each wired to 24, 3-pair 6-position modular jacks, USOC wiring. Black, blue, and red universal holddowns
SPB-V4 . . . . . . . . . . . . . . . . . . . Four, 25-pair connectors, each wired to 24, 4-pair modular jacks, USOC wiring. Black, blue, red, and green universal holddowns
SPB-V2-ETH . . . . . . . . . . . . . . . Two, 25-pair connectors, each wired to 24, 2-pair 8-position modular jacks, 10BASE-T wiring. One black, one blue universal holddown
SPB-V4-ATT . . . . . . . . . . . . . . . Four, 25-pair connectors, each wired to 24, 4-pair modular jacks, T568B wiring. Black, blue, red, and green universal holddowns
SPB-V4-TIA . . . . . . . . . . . . . . . Four, 25-pair connectors, each wired to 24, 4-pair modular jacks, T568A wiring. Black, blue, red, and green universal holddowns
U1 = 1-pair, 6-position jack, USOCU2 = 2-pair, 6-position jack, USOCU3 = 3-pair, 6-position jack, USOC*U4 = 4-pair jack, USOC*
A4 = 4-pair jack, T568BT4 = 4-pair jack, T568AE2 = 2-pair, 8-position jack, 10 BASE-TUT = 2-pair, 8 position jack, Token Ring
PRE-WIRED 25-PAIR CT® PANELS
The pre-wired category 3 CT® panel is well-suited for applications where hub equipment uses 25-pair connectors.Simply connect hub equipment to CT® panel using connectorized 25-pair cable assemblies (see page 6.10).
PART # DESCRIPTION
CT-PNL-(XX)-(XX)-01 . . . . . . . . . Pre-wired category 3 CT® panel
Use 1st (XX) to specify number of ports: 16, 24, 32, 48, 64, 96Use 2nd (XX) to specify jack wiring options: U1, U2, U3, U4, A4, T4, UK, E2, UT
BLANK FILLER PANELS
Blank filler panels are ideal for installations where open or expansion rackspace is to be covered. Panels are blank on one side and feature the SiemonCabling System® Logo on the other side.
PART # DESCRIPTION
PNL-BLNK-(X) . . . . . . . . . . . . . . Blank filler panel for 19 inch rack
PNL-BLNK-23-(X) . . . . . . . . . . . Blank filler panel for 23 inch rack
Use (X) to specify rack mount space height of panel: 1 = 1 RMS, 2 = 2 RMS, 3 = 3 RMS, 4 = 4 RMS,Note: 1 RMS = 44.5mm (1.75 in)
04 00-11 12/15/00 5:17 PM Page 11