Inspired thinking embracing the challenges of a changing world. Final Report Pathway to 2020 for Increased Stringency in New Building Energy Efficiency Standards: Benefit Cost Analysis: Commercial Buildings: 2016 Update transport | community | mining | industrial | food & beverage | carbon & energy Document Details Prepared for: Department of Industry, Innovation and Science Client representative: Stanford Harrison Date: 10 May 2016 Rev01

Final Report Pathway to for Increased Stringency Building ... · Buildings: 2016 Update transport | community | mining | industrial | food & beverage | carbon & energy

Embed Size (px)

Citation preview

Inspired thinking embracing  the challenges of a changing world.  

 

 

Final  Report  ‐  Pathway  to  2020  for  Increased Stringency  in  New  Building  Energy  Efficiency Standards:    Benefit  Cost  Analysis:  Commercial Buildings:  2016 Update  

transport | community | mining | industrial | food & beverage | carbon & energy 

        

Document Details   

Prepared for:  Department of Industry, Innovation and Science 

Client representative: Stanford Harrison

Date:  10 May 2016 

Rev01  

 

pitt&sherry ref: HB16076/Final Report 31‐P/Rev 01 

Table of Contents  

1.  Summary of Analysis ...................................................................................................................................... 1 2.  Results – All Australia ..................................................................................................................................... 3 

2.1  No learning rate .................................................................................................................................. 3 2.2  Learning rate 3% p.a for 10 years ....................................................................................................... 4 2.3  Learning rate 100% after 7 years ........................................................................................................ 4 2.4  Breakeven (BCR 1.0) results by climate zone ...................................................................................... 5 

3.  Discussion of updated results ........................................................................................................................ 8 4.  Comparison with 2012 results ....................................................................................................................... 9 5.  Research Questions ........................................................................................................................................ 9  

 Prepared by:  

 Phil McLeod Date:   10th May 2016 

Reviewed by:  

 Philip Harrington Date:   10th May 2016 

© 2016 pitt&sherry This document is and shall remain the property of pitt&sherry. The document may only be used for the purposes for which it was commissioned and in accordance with the Terms of Engagement for the commission. Unauthorised use of this document in any form is prohibited. 

 

pitt&sherry ref: HB16076/Final Report 31‐P/Rev 01  1 

1. Summary of Analysis 

Purpose 

This purpose of this study is to update the findings of the building benefit/cost analysis, for commercial buildings, undertaken for the report Pathway to 2020 for Increased Stringency in New Building Energy Efficiency Standards:  Benefit Cost Analysis (2012). The 2012 study analysed the range of cost‐effective savings in the energy consumption of new buildings that could be achieved in Australia by 2015 and 2020, relative to buildings compliant with the current, 2010 version of the Building Code of Australia (BCA2010), based on a number of defined scenarios. It was commissioned by the former Department of Climate Change and Energy Efficiency as a contribution to the National Building Energy Framework measure described in the former National Strategy on Energy Efficiency.  

In December 2015 the COAG Energy Council agreed to the National Energy Productivity Plan which includes a measure to advance the building energy performance requirements in the National Construction Code (measure 31).  In this context the Department of Industry, Innovation and Science commissioned an update on the benefit cost analysis contained in the 2012 report, for commercial buildings only, to help inform potential policy settings for future.   This  updated  analysis  largely  repeats  the  2012  study methodology,  albeit with  contemporary  price  and building stock observations and revised policy scenarios, as described below.  The purpose of this study  to help inform potential policy settings for building energy performance requirements in 2019 for Class 3 and 5 – 9 buildings  in the National Construction Code. The original study and this updated analysis should be read  in conjunction with each other.   Due to the change  in policy scenarios, the results of the 2012 study and 2016 Update are not strictly comparable.  That said, some scenarios in the two reports overlap and, as discussed below, the findings of the two reports are consistent with each other.  The performance levels identified here as being cost effective should be regarded as indicative only, as they are based on a point‐in‐time analysis of technical building performance improvement potentials and associated economic costs and benefits, for a limited number of building types, climate zones and policy scenarios.  The scope of this project did not allow for revised cost estimation or new building simulation modelling.  This would tend make the results conservative, as new materials, technologies, design concepts and cost reductions that have become available since 2012 would be likely to increase the scope of cost effective savings. 

Approach 

In summary this updated benefit cost analysis uses:   

Commercial building forms, building specifications and climate zones as per the 2012 Report; 

Contemporary  energy  price  projections  based  on  AEMO  forecasts without  a  carbon  price with  two different shadow carbon prices    i) based on  latest ERF auction outcomes ($12.25 tonne)  increasing at CPI and  ii)  the medium scenario  from  the Climate Change Authority  (CCA) 2014 Targets and Progress Review; 1; 

3  learning rates  i) 0% (no  learning)  ii) 100% after 7 years (i.e the  incremental cost falls to zero after 7 years), and iii) 3% per annum for 10 years. 

Changes in incremental costs since the original study, and also changes in the ‘opportunity set’ due to new/improved materials or technologies, have not been accounted for here; 

                                                            1 The shadow price of carbon  in this scenario begins at $5.49/t CO2‐e  in 2015 and rises to $30.14  in 2020, $36.67  in 2025, $44.61 in 2030 and $56.45 by 2036. 

 

pitt&sherry ref: HB16076/Final Report 31‐P/Rev 01  2 

A 7% real discount rate.  The  benefit  cost  analysis  assumes  that  new  performance  requirements  are  introduced  in  FY2019‐20, consistent with  an  assumed  start  date  of May  2019.      It  applies  to  a  ‘cohort’  of  buildings  constructed between 2020 – 20242. All buildings are assumed to have an economic life of 40 years and the benefit cost analysis is conducted over this period. Cost effective levels of energy savings are calculated on a breakeven basis (benefit‐cost ratio of 1) and benefit‐cost ratios of 1.2 and 1.5.   

Table 1 below shows the effect the different carbon price scenarios have on commercial electricity price forecasts in NSW (as an example). The carbon prices are relatively modest, so there is not a great difference in electricity price forecasts, particularly between the no and low carbon price scenario.   Table 1: Commercial (medium business) electricity price forecasts under different carbon price scenarios 

Electricity price NSW ($/GJ) 

2020 

2021 

2022 

2023 

2024 

2025 

2026 

2027 

2030 

2031 

2032 

2032 

2033 

2034 

2035 

2036 

No carbon price  42.9  42.8  42.9  44.3  45.8  47.4  47.4  47.4  47.4  47.4  47.4  47.4  47.4  47.4  47.4  47.4 

Low carbon price ($12.25 tonne rising with CPI) 

 45.9 

 45.9 

 46.0 

 47.4 

 48.9 

 50.5 

 50.5 

 50.5 

 50.5 

 50.5 

 50.5 

 50.5 

 50.5 

 50.5 

 50.5 

 50.5 

Medium carbon price (based on CCA targets and progress review) 

 50.4 

 50.6 

 51.0 

 52.8 

 54.6 

 56.6 

 56.9 

 57.3 

 57.7 

 58.1 

 58.6 

 59.0 

 59.5 

 60.0 

 60.5 

 61.0 

 Table 2 shows how  the  incremental cost rate varies under  the different  learning rate scenarios. Learning rates  refer  to  the  rate  of  reduction  in  incremental  costs  through  time,  consequent  upon  at  least  two factors:  first, innovation in designs, methods, tools, techniques and know‐how; and second, reductions in the unit costs of components, particularly those induced by the measure (for example, regulation may lead to increased economies of scale or induce innovation in the supply chain).   

The example below is the additional cost to achieve a 40% energy reduction (compared to BCA 2010) for a 3‐storey office building in Sydney. Under the no learning rate scenario incremental costs remain unchanged for the 5‐year cohort of buildings. On the other hand, under the highest learning rate scenario, incremental costs are assumed to fall from $153/m2 in 2020 to $31/m2 by 2024.  We note that there is uncertainty regarding the ‘correct’ value for the learning rate, hence the sensitivity analysis on a range of possible values.  Ideally further quantitative research would be undertaken in this area.  Table 2: Difference in incremental cost rates under different learning rate scenarios  

Learning rate   2020  2021  2022  2023  2024 

No learning rate  $153/m2  $153/m2  $153/m2  $153/m2  $153/m2 

3% p.a for 10 years  $153/m2  $148/m2  $144/m2  $139/m2  $135/m2 

Falling to 0% after 7 years (5% learning rate for the first two years, 15% in years three and four, 10% in year five, then 5% for years six and seven).  

 $153/m2 

 $115/m2 

 $77/m2 

 $54/m2 

 $31/m2 

 

                                                            2 As per the original report, the working assumption is that Code revisions may occur every 5 years, and therefore only a 5‐year cohort is modelled. 

 

pitt&sherry ref: HB16076/Final Report 31‐P/Rev 01  3 

Key Findings 

This updated analysis confirms the findings of the 2012 study that there are very significant cost effective opportunities  for energy savings  in new commercial buildings  in 2020 relative  to  (BCA) 2010, particularly when a BCR target of 1 or 1.2 is selected.   

For example, even if no learning is assumed, average savings of 35% are cost effective with a low shadow carbon price and a BCR of 1.  With a higher shadow carbon price and a target BCR of 1, savings of 47% on average are cost effective, even with no  learning.    If  learning  is set at 100% over 7 years, then savings of between 50% and up to 80% are shown to be cost‐effective, depending upon the scenario selected.  At the other end of the spectrum, if a target BCR of 1.5 is specified and no learning, then savings (of 14%) are cost effective  only  with  the  ‘medium’  carbon  price  assumption,  and  none  at  all  with  lower  carbon  price assumptions. 

This  summary  illustrates  the  sensitivity  of  what  is  deemed  to  be  ‘cost  effective’  as  a  function  of  key parameter assumptions, and notably the  learning rate.   We conclude from this that careful and evidence‐based research, and not assumptions, should be used as the basis for determining key values – or better, ranges of values – when undertaking full benefit‐cost analysis and regulatory impact assessment. 

That said, while there are variations in the degree of cost effective savings by climate zone and by building type, and by policy scenario, these variations are around mean values which are high and quite robust  in the  face of the sensitivity analyses  included  in  this study. This overall result  is attributed primarily to  the relatively  low stringency for commercial buildings  in BCA20103, which means that many opportunities for energy savings that were cost effective at that time were not taken up.  Secondly, energy prices have risen more  strongly  than was anticipated  in  the 2012  study, offsetting  the  reduction  in actual/shadow carbon prices.   

We stress that these findings are based on a limited‐scope update of certain modelling parameters.  Further and more comprehensive analysis would be required to support a regulation impact assessment, for example.  That said, we consider it likely that if an updated ‘savings opportunity set’ were modelled, along with updated incremental costs, higher savings than those reported here would be deemed cost effective (for each policy scenario). 

2. Results – All Australia 

The results below are presented under the 3 learning rate scenarios. For each scenario results are then shown for the 3 different energy prices modelled.   Percentage energy reductions from BCA 2010 are weighted averages for all relevant commercial buildings in Australia. Energy intensities as a result of the energy savings are also shown. The energy intensities are also weighted averages based on the proportions of the total Australia stock in each climate zone.  

2.1 No learning rate 

Table 1 below shows that even with no  learning rate, energy savings can be achieved under each energy price scenario at break‐even and BCR 1.2 levels. At higher energy costs because of a carbon price, the more 

                                                            3 The 2012 study found that the BCA2010 stringency level was associated with a BCR of around 2.2, meaning that very many  cost effective  savings were not  taken up at  that  time.   Generally  the  level of  cost effective  savings  tends  to increase through time, due to at least three factors:  real energy price increases; real cost declines (typically but not always)  in  key  energy  using  equipment,  designs  and  materials;  and  adoption  of  new  techniques  and  ‘industry standards’ over time for market/non‐regulatory reasons, such as meeting NABERS or Green Star targets. 

 

pitt&sherry ref: HB16076/Final Report 31‐P/Rev 01  4 

cost effective energy savings become. Energy savings of 14% at the benefit cost ratio of 1.5 can be achieved under the medium carbon price scenario.  

Table 3: All Australia results, no learning rate  

  No carbon price    ERF (low) carbon price    Medium carbon price   

BCR  %  energy  reduction from BCA2010 

MJ/m2.a  %  energy  reduction from BCA2010 

MJ/m2.a % energy reduction from BCA2010 

MJ/m2.a

1.0  29%  358  35% 328 47%  268

1.2  13%  436  20% 401 34%  330

1.5  *    *  14%  428

* Can’t be achieved for this scenario 

2.2 Learning rate 3% p.a for 10 years 

Table 2 below shows the results where the learning rate is a modest 3% per annum for 10 years. So after 10 years  the  incremental cost has  reduced by 30% and  thereafter  there  is no  further  reduction. Break even energy savings of up to 53% can be achieved under the medium carbon price scenario. Energy savings at a BCR of 1.5 are realized for the low and medium carbon price scenarios; 7% and 23% respectively.  

Table 4: All Australia results, learning rate 30% after 10 years  

  No carbon price scenario     ERF carbon price    Medium carbon price   

BCR  %  energy  reduction from BCA2010 

MJ/m2.a  %  energy  reduction from BCA2010 

MJ/m2.a % energy reduction from BCA2010 

MJ/m2.a

1.0  37%  320  42% 292 53%  238

1.2  22%  390  28% 358 41%  294

1.5  *     7% 462 23%  384

* Can’t be achieved for this scenario 

2.3 Learning rate 100% after 7 years 

Table 3 below shows the results where the learning rate increases to 100% after 7 years. Significant break‐even energy savings,  ranging  from 70%  to 80% depending on energy prices, can be achieved. Under  this learning rate scenario energy savings of at least 50% can be achieved for a BCR of 1.5. 

Table 5: All Australia results, learning rate 100% after 7 years  

  No carbon price scenario  ERF (low) carbon price  Medium carbon price 

BCR  %  energy  reduction from BCA2010 

MJ/m2.a  %  energy  reduction from BCA2010 

MJ/m2.a % energy reduction from BCA2010 

MJ/m2.a

1.0  70%  150  73% 134 80%  102

1.2  62%  189  66% 170 73%  133

1.5  50%  250  54% 228 63%  182

 

 

pitt&sherry ref: HB16076/Final Report 31‐P/Rev 01  5 

2.4 Breakeven (BCR 1.0) results by climate zone 

The tables below show a breakdown of results by climate zone for the break‐even energy savings for each of the scenarios described above. There is a reasonable spread of results by climate zone, with the hotter climate zones with greater electricity use for space conditioning, and also those with higher electricity prices, tending to show more cost effective savings.  At the highest learning rate (tables 10‐12) the level of break‐even energy savings is the greatest. 

2.4.1 No learning rate 

No carbon price 

Table 6: No learning rate, no carbon price results  

 

Climate zone 

%  Energy 

reduction  from 

BCA 2010  

 

MJ/m2.a 

Sydney (CZ5)  35% 326 Darwin (CZ1)  68% 233 Brisbane (CZ2)  46% 285 Adelaide (CZ5)  30% 350 Hobart (CZ7)  26% 374 Melbourne (CZ6)  7%  468 Perth (CZ5)  40% 297 Canberra (CZ7)  32% 363 Weighted average  29% 358 

ERF carbon price 

Table 7: No learning rate, ERF carbon price results 

Climate zone  %  Energy 

reduction  from 

BCA 2010  

 

MJ/m2.a 

Sydney (CZ5)  41% 294 Darwin (CZ1)  70% 221 Brisbane (CZ2)  51% 260 Adelaide (CZ5)  34% 328 Hobart (CZ7)  17% 415 Melbourne (CZ6)  16% 422 Perth (CZ5)  42% 286 Canberra (CZ7)  38% 332 Weighted average  35% 328 

 

   

 

pitt&sherry ref: HB16076/Final Report 31‐P/Rev 01  6 

Medium carbon price 

Table 8: No learning rate, medium carbon price results 

Climate zone  %  Energy 

reduction  from 

BCA 2010  

 

MJ/m2.a 

Sydney (CZ5)  50% 248 Darwin (CZ1)  76% 179 Brisbane (CZ2)  59% 215 Adelaide (CZ5)  44% 281 Hobart (CZ7)  21% 396 Melbourne (CZ6)  35% 323 Perth (CZ5)  50% 246 Canberra (CZ7)  47% 284 Weighted average  47% 268 

2.4.2 Learning rate 3% per annum 

No carbon price 

Table 9: Learning rate 3% per annum, no carbon price results 

Climate zone  %  Energy 

reduction  from 

BCA 2010  

 

MJ/m2.a 

Sydney (CZ5)  41% 293 Darwin (CZ1)  73% 200 Brisbane (CZ2)  53% 251 Adelaide (CZ5)  38% 311 Hobart (CZ7)  33% 337 Melbourne (CZ6)  17% 417 Perth (CZ5)  46% 264 Canberra (CZ7)  38% 328 Weighted average  37% 320

ERF carbon price 

Table 10: Learning rate 3% per annum, ERF carbon price results 

Climate zone  %  Energy 

reduction  from 

BCA 2010  

 

MJ/m2.a 

Sydney (CZ5)  47% 264 Darwin (CZ1)  74% 189 Brisbane (CZ2)  57% 229 Adelaide (CZ5)  42% 290 Hobart (CZ7)  25% 377 Melbourne (CZ6)  25% 376 Perth (CZ5)  48% 254 Canberra (CZ7)  44% 299 Weighted average  42% 292 

 

pitt&sherry ref: HB16076/Final Report 31‐P/Rev 01  7 

Medium carbon price 

Table 11: Learning rate 3% per annum, medium carbon price results 

 

 

2.4.3 Learning rate 100% after 7 years 

No carbon price 

Table 12: Learning rate 100% after 7 years, no carbon price results 

 

Climate zone 

%  Energy 

reduction  from 

BCA 2010  

 

MJ/m2.a 

Sydney (CZ5)  70% 149 

Darwin (CZ1)  93% 55 Brisbane (CZ2)  80% 106 Adelaide (CZ5)  73% 135 Hobart (CZ7)  65% 176 Melbourne (CZ6)  62% 193 Perth (CZ5)  76% 116 Canberra (CZ7)  67% 173 Weighted average  70% 150 

ERF carbon price 

Table 13: Learning rate 100% after 7 years, ERF carbon price results 

 

Climate zone 

%  Energy 

reduction  from 

BCA 2010  

 

MJ/m2.a 

Sydney (CZ5)  74% 131 Darwin (CZ1)  93% 49 Brisbane (CZ2)  82% 93 Adelaide (CZ5)  75% 124 Hobart (CZ7)  60% 203 Melbourne (CZ6)  66% 169 Perth (CZ5)  77% 111 Canberra (CZ7)  71% 154 

 

Climate zone 

%  Energy 

reduction  from 

BCA 2010  

 

MJ/m2.a 

Sydney (CZ5)  56% 222 Darwin (CZ1)  79% 151 Brisbane (CZ2)  64% 189 Adelaide (CZ5)  50% 248 Hobart (CZ7)  29% 359 Melbourne (CZ6)  43% 286 Perth (CZ5)  56% 218 Canberra (CZ7)  52% 256 Weighted average  53% 238 

 

pitt&sherry ref: HB16076/Final Report 31‐P/Rev 01  8 

 

Climate zone 

%  Energy 

reduction  from 

BCA 2010  

 

MJ/m2.a 

Weighted average  73% 134 

Medium carbon price 

Table 14: Learning rate 100% after 7 years, medium carbon price results 

 

Climate zone 

%  Energy 

reduction  from 

BCA 2010  

 

MJ/m2.a 

Sydney (CZ5)  79% 106 Darwin (CZ1)  96% 26 Brisbane (CZ2)  87% 70 Adelaide (CZ5)  80% 101 Hobart (CZ7)  62% 192 Melbourne (CZ6)  77% 116 Perth (CZ5)  82% 90 Canberra (CZ7)  76% 128 Weighted average  80% 102 

 

3. Discussion of updated results 

While the different energy price scenarios affect the results to some degree, the biggest influence on the varying level of energy savings is the learning rate. Under the no carbon price scenario, for example, break‐even energy savings range from 29% (all Australia results) where the learning rate is zero, to 70% where the learning rate is 100% after 7 years.   As reported in 2012, a key driver of the generally high level of cost effective energy savings for commercial building results is the relatively low starting point implicit in BCA2010.  Further, it is generally accepted in the building industry that industry standards and practices have moved on significantly in recent years, in part due to the influence of programs such as NABERS and Green Star, but also due to new technologies and a growing appreciation of the value of energy efficiency.  Due to relatively modest performance requirements being set in 2010, many savings opportunities that were cost effective at that time were not taken up.  As a result, they remain available, and this significantly increases the overall level of savings that are available now.  In addition, energy prices for electricity and gas, and also the mix of fuels used in different building types and climate zones, impact on the results. These effects are accentuated in commercial as distinct from residential buildings due to their significantly higher energy intensity (energy use per square metre).   The relatively lower level of cost effective savings in Canberra, Hobart and Melbourne is largely attributable to higher gas use in these cooler climates, with gas savings being less valuable than electricity savings, and also due to relatively lower electricity prices in those states. By contrast, the hotter climate zones with greater electricity use for space conditioning, and also those with higher electricity prices, tend to show more cost effective savings. 

 

pitt&sherry ref: HB16076/Final Report 31‐P/Rev 01  9 

4. Comparison with 2012 results 

The 2012 study called for an analysis of energy savings at ‘break‐even’ benefit cost ratio (BCR = 1), although some scenarios also  tested a BCR of 1.2.   The 2012 study used  two different discount  rates, and  for  this section we  report only  those with a 7%  real discount  rate.    In  terms of policy  scenarios,  the 2012  study specification required that scenarios reflected a mix of different carbon prices and differing  learning rates rather than treating these independently.   

Specifically, Scenario 1 in the 2012 study assumed no carbon prices and no learning and so is comparable to the similar scenario from this study.  Scenario 2 in the 2012 study assumed 3% p.a. learning rate and a ‘low’ carbon price assumption.   The carbon price assumptions  for  that study were based on  the “Government policy”  (Scenario 2) and “High price”  (Scenario 3) based  respectively on scenarios  in  the Treasury’s 2011 economic modelling  of  the  Clean  Energy  Future  legislative  package.     We  note  that  this  carbon  price assumption was higher  than  the  ‘medium’  carbon price  scenario  in  this  report..   Scenario 3  in  the 2012 study assumed a 5% p.a. learning rate over 10 years (that is, 50% of the incremental costs remain after 10 years) and a carbon price trajectory of $27.50 in 2013, $62/t in 2020, and $147.80 by 2035.  

With no carbon price and no learning, the break‐even (BCR = 1) 2016 results are lower than the 2012 ones. 29% energy savings would be cost effective in 2016, compared to 44% savings in 2012 for a similar scenario.  The  lower savings  in 2016 are due to the difference  in forecast electricity prices used for the original and updated  study  (see  table 15 below as an example). The electricity price  forecasts used  in 2012 were  for medium/small consumers.  The 2016 prices are for medium consumers and are lower than the 2012 prices. We believe  the owner of a medium  size office building or  small  shopping mall  is more  likely  to pay  the medium consumer price, although the  issue of commercial prices, and who pays what,  is  increasingly  less transparent in the wake of full retail contestability. Another factor leading to lower savings in 2016 is that assumptions  about network  costs were higher  in 2012  than now,  reflecting  the expected  lower  level of network infrastructure investment in coming years when compared with the past five years or more.  Table 15: Comparison of forecast electricity prices used in 2012 and 2016 (NSW) 

Electricity price 

NSW ($/GJ) 

2020 

2021 

2022 

2023 

2024 

2025 

2026 

2027 

2030 

2031 

2032 

2032 

2033 

2034 

2035 

2036 

2016 update  42.9  42.8  42.9  44.3  45.8  47.4 47.4 47.4 47.4 47.4 47.4 47.4  47.4  47.4  47.4 47.4 2012 study 

 56.0  56.2  56.4   56.5   56.7   57.3  58.2   57.1   57.3  55.6    55.9  56.2  56.5   56.4  56.0  56.2 

 In  the 2012 study,  the  learning  rate was not able  to be varied  independently of other variables, and nor were carbon prices, whereas  in 2016 we have treated these variables separately, to better  illustrate their relative  contributions  to  the  overall  results.    Therefore we  can  see  that  even  in  the  ‘no  carbon  price’ scenario,  the  cost  effective  level  of  energy  performance  is  highly  contingent  on  the  learning  rate assumption.  A very modest learning rate of 3% per year – which we consider unrealistically low – already lifts the cost effective improvement from 29% to 37%, while an assumption of 100% learning over 7 years lifts the figure to 70%.   

5. Research Questions 

The  comparison of  the  2012  and  2016  study  results  reinforces  the need  to  address  some  key  research questions.   

First, amongst these is the choice of an appropriate learning rate.  Since this is clearly a significant variable, an  evidence‐based,  rather  than  assumption‐based,  approach  is  critical.    Targeted  research  using  sound 

 

pitt&sherry ref: HB16076/Final Report 31‐P/Rev 01  10 

methodologies  needs  to  be  undertaken  to  establish  a  value  or  plausible  range  of  values  for modelling purposes.    Industry  stakeholders may be able  to  contribute  to  this  research, but  there  is a  clear  risk of strategic bias that must be understood and designed into the research methodology.  Second, the choice of benefit cost ratio for regulation impact assessment purposes also requires a rigorous treatment.    There  is widely  held  belief  that  higher  benefit  cost  ratios  are  ‘better’  than  lower  ones,  or, secondly,  that a BCR > 1  should be used as a  ‘confidence margin’, or  to manage possible uncertainty  in results.  These have no basis in economic or public finance theory.  Setting a policy target where the BCR > 1 by definition means that cost‐effective savings opportunities are being foregone, creating an opportunity cost of foregone economic welfare.  Where there is uncertainty in values, the first‐best solution is conduct evidence‐based  research  to  reduce  that uncertainty.    Second,  for  remaining  and  legitimate uncertainty, appropriate valuation techniques such as the use of probability‐weighted or ‘expected’ values, or ranges of results, should be used rather than varying benefit cost ratios as a proxy.   Third, we  note  again  that  this  quick  update  has  not  updated  underlying  cost  assumptions,  the  energy savings opportunity set or the cost/savings opportunities in mechanical equipment and lighting, etc.   

Fourth,  both  the  2012  and  2016  studies  have  an  implicit  assumption  that  NCC  energy  performance requirements  are  in  fact  complied with.   However,  our  2014 National  Energy  Efficient Buildings  Project Phase 1 report raises material doubt about that.  As recommended in that report, we note that significant quantitative  research will  be  required  to  establish  the  extent  and materiality  of  non‐compliances with respect to their impact on the actual energy performance of the building stock. 

 

 

Contact:  Philip Harrington Senior Principal, Carbon & Energy [email protected] (03) 6210 1489 0419 106 449   

transport | community | mining | industrial | food & beverage | carbon & energy 

 

   

 

Contact Details       

Brisbane  Devonport  Launceston  E: [email protected]  

Level 2 276 Edward Street Brisbane QLD 4000 T: (07) 3221 0080 F: (07) 3221 0083 

Level 1 35 Oldaker Street PO Box 836 Devonport TAS 7310 T: (03) 6424 1641 F: (03) 6424 9215 

Level 4113 Cimitiere Street PO Box 1409 Launceston TAS 7250 T: (03) 6323 1900 F: (03) 6334 4651 

W: Pitt & Sherry  

incorporated as Pitt & Sherry (Operations) Pty LtdABN 67 140 184 309

Canberra   LGF, Ethos House 28‐36 Ainslie Place Canberra City ACT 2601 PO Box 122 Civic Square ACT 2608 T: (02) 6274 0100 

Hobart  199 Macquarie Street GPO Box 94 Hobart TAS 7001   T: (03) 6210 1400 F: (03) 6223 1299 

Melbourne Level 1, HWT Tower 40 City Road Southbank VIC 3006 PO Box 259   South Melbourne VIC 3205 T: (03) 9682 5290 F: (03) 9682 5292