    FactoryTalk View Machine Edition 6.1

    Versatile Machine-Level HMI for Stand-Alone Applications

    FactoryTalk View Machine Edition (ME) sotware is a versatile HMI

    application that provides a dedicated and powerul solution or

    machine-level operator interace devices. As an integral element o the

    Rockwell Automation visualization solution, FactoryTalk View Machine

    Edition provides superior graphics, runtime language switching and aster

    commissioning time through a common development environment.

    FactoryTalk View Machine Edition 6.1 adds new eatures that speed

    development time by up to 30 percent, while enhancing the unctionality

    and impact o HMI applications or machine-level, PC-based operator

    interace solutions. These new eatures include

    Complete Symbol Factory Library to allow users to create more eective

    and compelling displays, in less time. Ability to embed browser window

    in HMI - applicationsoperators can easily access documentation, recipes

    and other html-content without direct control o the browser.

    Extend capabilities or data-logging and recipe management

    using a common .csv le ormat.

    A built-in Microsot Arial Unicode ont that allows one run-time

    application to be deployed in up to 20 languages withoutcumbersome ont-linking.

    A stand-alone version o the Machine Edition Transer Utility simplies

    loading applications on to PanelView Plus without having to install

    and have a license or FactoryTalk View Studio.

    Features and Benefts

    FactoryTalk View Machine Edition

    oers OEMs and end-users eatures

    that reduce development and

    commissioning time, while improving

    the operators experience and

    retaining the plant-wide scalability.

    Reduce design and commissioning

    time with:

    TaglessHMIwiththe

    FactoryTalk Directory

    Globalobjects

    LibraryofRockwellAutomation

    Built-in Faceplates and

    Add-On Instructions

    Now compatible with

    Windows 64-bit OS

    Expand machine exibility

    and capability through:

    Recipes

    Machineset-up

    Datalogging

    Using the .csv le ormat, FactoryTalk

    View ME can write data logs that are

    accessible via FTP on an Ethernet

    network or trending analysis. Similar

    .csv les can be stored on the local

    PC or PanelView and used to modiy

    values in the controller or recipe

    changes and/or machine set-up.

    These recipes can be downloaded

    to the local terminal via an Ethernet

    network, as well.

    Runtime language switching

    The built-in Microsot Arial Unicode

    ont includes virtually all Unicode

    character ranges, meaning that

    multiple-language implementations

    can be accomplished more easily,

    without cumbersome ont-linking.

  • 7/30/2019 Ftalk Pp012 en p

    2/4

    Optimized ControlLogix CommunicationsUsing RSLinx Enterprise

    Optimize Your Investment

    FactoryTalk View ME provides premier integration

    with Rockwell Automation Integrated Architecture,

    maximizing your existing control system investment. For

    example, RSLinx Enterprise communications oer native,

    optimized communications to Logix platorms. Enabled

    by FactoryTalk Directory, FactoryTalk View Machine Editionallows browsing to a local directory or RSLogix tag

    addresses and accessing controller tags directly.

    FactoryTalk View Machine Edition supports KepServer

    Enterprise sotware, which provides serial and Ethernet

    OPC servers that allow communication between many

    third-party programmable controllers, industrial devices

    and FactoryTalk View Machine Edition.

    Reduce Commissioning Time FactoryTalkView Machine Edition Delivers

    Tagless HMI with the FactoryTalk DirectoryFactoryTalk Directory gives you access to tags held in

    controllers by reerencing them through a common

    address book. For example, tags dened in RSLogix

    programming sotware and reerenced via RSLinx

    communications sotware, are automatically available

    or browsing and accessing in a local directory. With

    FactoryTalk Directory, theres no need to recreate or

    import tags into a separate tag database.

    Global Objects

    GlobalobjectsallowyoutolinktheappearanceandbehaviorofabasegraphicobjecttomultiplereferencesoftheobjectthroughoutaFactoryTalkViewapplication,savingyoudevelopmenttime.GlobalObjectparametersallow the creation o reusable parameterized aceplatesand templates. Usability is enhanced by the ability todeploy aceplates and templates at design time, andparameterized element can be substituted with top-levelUDT tag support.

    Library o Rockwell Automation Built

    Faceplates and AOIs

    The library o aceplates and AOIs:

    Provides or monitoring status o I/O, controllers andnetworks, and or control o some o these devices

    Saves time, can easily be added to any HMI application

    Are automatically updated as Rockwell Automationintroduces new and updated aceplates and AOIs

    Confgure and Monitor Alarm Conditions

    The FactoryTalk View alarm system quickly alerts youand your operators to conditions requiring immediateaction. You can use the Alarm Setup editor to congurealarm conditions. When an alarm condition occurs duringruntime, the system can pop up a predened display,sound an alarm signal, or send the alarm to a printer.Alarm system eatures include:

    Word alarm triggers based on analog tags,digital tags, or expressions

    Bit and least-signicant bit alarm triggers

    Ability to acknowledge, silence, and clear alarms

    Complete Symbol Factory Libraryto enable users to createmore efective and compellingdisplays, in less time.

  • 7/30/2019 Ftalk Pp012 en p

    3/4

    Recipes, Machine Set-Up and Data Logging

    Using the .csv le ormat, FactoryTalk View ME can

    write data logs or oine trending analysis.

    Similar .csv les can be stored on the local PC or

    PanelView and used to modiy values in the controller

    or recipe changes and/or machine set-up. These

    recipes also can be downloaded to the local terminal

    via an Ethernet network.

    Keeping System Data Secure

    FactoryTalk Security provides security services

    integrated into both the FactoryTalk local directory and

    the FactoryTalk network directory. FactoryTalk Security

    supports security policies that govern how security is

    implemented. For example, a security policy can dene

    the rules or passwords regarding how many characters

    are required and how complex passwords must be.

    Scalability to Grow

    FactoryTalk View Studio Scale Machine-LevelHMI Applications Across Multiple Platorms

    The common development environment used across

    the FactoryTalk View suite and PanelView Plus operator

    terminals expands the scope o traditional machine-level

    HMI development rom dedicated devices to a much

    broader scale that includes open Microsot Windows

    CE solutions and Microsot Windows desktop operating

    systems. FactoryTalk Machine Edition is part o the

    FactoryTalk Enterprise Series, which oers a scalable

    HMI architecture, making it easy to reuse components

    o machine-level applications within supervisory-level

    projects.Thesolutionalsoencompassesexiblesystem

    consisting o activation procedures, a common address

    book, centralized authentication and access control,

    and uniorm diagnostics that can help reduce costs and

    extend the lie cycle o your existing investments.

    Simulate Runtime with Quick Test

    Run CapabilitiesTo make it easy to test your systems as you build them,

    FactoryTalk View Studio includes quick test eatures.

    Quick Test Run operates rom within the graphics editor

    toverifyoperationoftheobjectsandanimationswithin

    the graphic. The ull test run rom FactoryTalk View Studio

    oers a time-limited runtime to check connectivity with

    RSLinx and OPC and allows the running o the complete

    application rom within the development environment.

    Runtime Application ConversionEquals Easier Migration

    An automated wizard lets you import PanelViewStandardandPanelViewEnhancedprojectsinto

    FactoryTalk View Machine Edition applications via

    FactoryTalk View Studio. The process successully retains

    mostofaPanelViewproject,includinggraphicdisplays

    andmostobjects,text,tags,alarmmessages,andlocal

    and global messages.

    Rockwell Automation Library o Faceplates and AOIs

    Logix I/O

    Control Devices

    PowerFlex70/70 EC

  • 7/30/2019 Ftalk Pp012 en p

    4/4

    Publicati on FTALK-PP012D-EN-P May 2012 Copyright 2012 Rockwell Automatio n, Inc. All Rights Reserve d. Printed in USA.Supersedes Publication FTALK-PP012C-EN-P November 2010

    Allen-Bradley, ControLogix, FactoryTalk, Integrated Architecture, PanelView, PowerFlex,RSLinx, RSLogix and Rockwell Sotware are trademarks o Rockwell Automation, Inc.All other trademarks and registered trademarks are the property o their respective owners.

    Multiple Version Support

    FactoryTalk View Studio allows you to create runtime

    applications (.mer les) or use with previous FactoryTalk

    View Machine Edition runtime versions, giving you the

    option o maintaining an installed base o older runtime

    versions and PanelView Plus and PanelView Plus CE

    terminals while using the latest FactoryTalk View Studio

    editor. This eliminates the time required to upgrade and

    requaliy the runtime sotware or upgrade terminals tothe latest rmware.

    Runtime Language Switching

    FactoryTalk View Enterprise, both FactoryTalk View Site

    Edition and FactoryTalk View Machine Edition, supports

    Runtime Language Switching o 20 runtime and 40

    design-time languages. You have the ability to congure

    multiple language versions o an application with the

    capability o switching application languages dynamically

    at runtime. Text within alarm, local and inormation

    messages,aswellastextembeddedingraphicsobjects,

    can be translated easily using the string import/exportto Microsot Excel eature. This eature optimizes

    duplicate strings and allows a single translation or strings

    that appear multiple times in the application. The built-in

    Microsot Arial Unicode ont includes virtually all Unicode

    character ranges so multiple-language implementations

    can be accomplished more easily, without cumbersome

    ont-linking.

    Get Answers Fast

    When you purchase any product in the FactoryTalk

    View Machine Edition amily, you receive both

    industry-leading sotware, and award-winning global

    support. Use the MySupport eature to personalize the

    Rockwell Automation Support Services website or your

    needs. MySupport can send you regular e-mail messages

    with links to the latest technical notes and sotware

    updates or FactoryTalk View Machine Edition and otherproducts. To register, visit

    http://support.rockwellautomation.com.

    Get More Inormation

    For ordering inormation, contact your local

    Rockwell Automation sales ofce or Allen-Bradley

    distributor. Or learn more by visiting