systeMGNS2000 Series
Stand Alone Generator Set Controller
governors america corp., 720 silver street agawam, Ma 01001phone: 413.786.5600 fax: 413.789.7736
1
advanced control & Monitoring • Engine Start/Stop Control• Engine & Generator Monitoring &
Protection• Remote Monitoring & Alerts• Comprehensive Metering • Fixed, Auto Detection & Binary Select
Schemes
Expanded off ering of I/o• 18 Confi gurable Binary Inputs & Outputs• 2 Form A and 2 Form C Relays• 4 Versatile Analog Input that Support:
VDO, 5VDC, 0-20 mA, Resistive & Thermocouple
Intuitive, Adaptable user Interface • Simultaneous Multi-Lingual Support• Local, Remote & No Display Support• Multiple Security Levels & Panel Lock• User-friendly smartVu Configuration
Software
high degree of Connectivity & Compatibility
• SAE J1939 • MODBUS• RS-232/485• SMS Support • Ethernet
highly developed design • Robust 600V Design
(min. 25% over voltage allowed)• 3 Built In Voltage Confi guration/Protection Methods• UL Approved* , CSA Compliant*, CE
Compliant• NFPA110 Level 2 Compatible• Industrial Temperature Range• Resistant to salt fog, humidity, dust, dirt,
and chemical contaminants*• Audible & Tactile F/B on Buttons for
Gloved Fingers
* Non E Versions Only
gac’s Generators Set Controller Series (GNS2000 Series) is a family of highly-fl exible generator set controllers for standalone applications. The GNS2000 Series, designed for both electronically and mechanically controlled engines, is ruggedly constructed with simple-to-use microprocessor technology. gac’s new controller series provides superior generator set control, protection, and metering all at a reasonable cost.
Programming the GNS2000 Series is easily accomplished by utilizing either the front panel navigation keys and the large LCD display or with gac’s enhanced smartVu™ confi guration software. The controller senses engine parameters directly via 4 analog inputs and it can communicate with the engine’s electronic control unit via J1939 CANbus protocol. The programmable inputs and outputs are engineered to allow the user to easily customize the operation as desired.
The GNS2000 Series has been designed to provide maximum functionality at a minimum price. Standard features include: 9 programmable inputs and 9 programmable outputs; 4 analog inputs that support a wide range of senders; 2 Form A and 2 Form C relays; robust electronic protection; fi xed, variable and binary voltage detection schemes; remote control and monitoring; one built in RS-232/485 port and one RS232 (GNS2004B GNS2004BE) with expansion for fi eld service laptop support; Modbus and J1939 CANbus interface; multiple, memory-resident languages: and an industrial temperature range operation of -40° to +85°C. To reduce costs, gac offers within the GNS2000 Series a no display, black-box version and an optional operating temperature range (-20° to +85°C) version.
Added features are easily incorporated in the unit without adding on high additional costs. Optional features include: internal and external modem; analog user interface; remote displays, relays and control modules; and expandable I/O capabilities via J1939 CANbus.
As with all gac products, the GNS2000 Series can be easily and cost effectively adapted to provide customized solutions for OEMs.
gns2002e genset controller
gns2004b black box genset controller
OVERNORS
MERICA
ORP.CAG
™
ISO 9001CERTIFIED
This document is subject to change without notice. Caution: None of GAC products are flight certified controls including this item.
2PTI 4123 D
Operating MOdesThe GNS2000 Series can be operated in Manual, Auto or Off modes, and has a full suite of engine and generator protections. When in Manual mode, the GNS will start and stop the engine based on user inputs. In Auto mode, the GNS will start and stop the engine when the remote start/stop input is received. Voltage detection is possible via one of three methods, auto-detection, fixed voltage operation, or assign binary inputs to indicate the desired voltage.
alarMs, Warnings, and prOtectiOnsThe GNS alarms and warnings alert the user while protecting the generator and engine. Virtually all protections can be individually enabled or disabled. Shutdown conditions include low oil pressure, low fuel level, high coolant temperature, under/over speed, under/over voltage, over current, over frequency, sensor failures, over crank, and generator voltage unbalanced.
EnginE COntrOl
• Cranking control provides pre-lube, up to 4 pre-start stages, adjustable number of crank attempts, duration, pause delay and crank disconnect. Also provided is an engine start counter.
• Enginetimersincludeservice,pre-start,crank,idle,cool down, and after cool.
• Adjustable protection thresholds and delays forspeed, oil pressure, coolant temperature, and fuel level.
• Integrationw/J1939ECUs.
MEtEring
• Meteredgeneratorparametersincludelinevoltage,line to line voltage, current, frequency, reactive power, power factor and actual power.
• Metered engine parameters include RPM, oilpressure, coolant temperature, battery voltage, fuel level, service hours, run hours, and number of starts. RPM, oil pressure, and coolant temperature can be acquired via J1939.
inputsThe GNS is equipped with dedicated inputs for generator voltage, generator current, and a speed sensor. The unit is also equipped with 4 configurable analog inputs and 9 configurable binary inputs. The analog inputs allow a wide range of sensors including voltage, current, and resistive senders. Though easily reconfigured, three of the analog inputs are configured for Fuel level, Engine temperature, and Oil Pressure. The GNS2000 Series can use J1939 messages for oil pressure, engine speed, and coolant temperature in combination with the analog inputs for control and protection operations, thereby, freeing up analog inputs for other sensors.
OutputsThe GNS2000 Series is equipped with 5 discrete binary outputs and four relays. The discrete outputs can sink up to 500mA of current to battery ground and support up to 32VDC. The GNS2000 Series has four relays, two Form C and two Form A. Though reconfigurable, one Form C relay is configured to control the fuel solenoid, the other is configured to control the starter. By adding a jumper (located on the back of the GNS), the fuel relay can be configured to be directly controlled by the emergency stop input – when the emergency stop input is activated, power to the fuel solenoid is removed, thereby depriving the engine of fuel.
All GNS2000 Series analog inputs, binary inputs, relays and binary outputs assignments can be configured by the user.
RS232/485, SAE J1939, EthERnEt, ModbuSThe standard GNS is equipped with a SAE J1939 port and one serial port. The serial port can be configured for RS232 or RS485 operation. The RS232 can connect the GNS to an external modem, external I/O, remote display, Ethernet converter or PC using the industrystandardMODBUSprotocol. A factory installedmodemcan be ordered or an external modem can be added to provide dial in and dial out remote monitoring**. For SMS functions, an external cell modem can be added. Note: the GNS2004B and GNS2004BE is a stand-alone controller equipped with an additional RS232 ports and can be operated without a display.
reMOte annunciatOr, Output relays, & prOgraMMable lOgic
The optional gac Remote Annuciator (RA20) and Contact Relay Module (CRM20) provide external programmable logic and annunciation for the GNS2000 Series. The RA20 is equipped with 20 LEDs and can be panel mounted. The CRM20 is similar to the RA20 with the inclusion 20 Form C relays. Both of these devices have 30 blocks for logic programming and can source data via Modbus over two RS-232/485 ports and J1939 over CAN bus.
gns2000 displayThe GNS2000 Series is equipped with a 64 x 128 graphical display, status LEDs, buttons (with the exception of GNS2004B and GNS2004BE). Depending on the configuration the display can support mulitple languages simultaneously. The user can switch between the languages on the fly.
** Coming Soon
This document is subject to change without notice. Caution: None of GAC products are flight certified controls including this item.
3PTI 4123 D
GnS display Real time Information
• OperatingMode• LineVoltage• LinetoLineVoltage• Current• Frequency• OilPressure
• EngineTemperature• GeneratorState• ActiveAlarmsand
Warnings• BinaryInputs• BinaryOutputs
• AnalogMetering• PowerMetering• GeneratorMetering• History• Power(RealPower,Apparent
Power, Power Factor)
System Settings
Password LoginChange PasswordVolt DetectNomPwr3PHNomPWR1PHNominal VoltNominal AmpsNom FreqGen ConfigV Det DelayZero LegHighLegCT RatioPT RatioFeedback Delay Gear TeethGCB DelayD+HornPeriodSpeed Inputs MasterSpeed Inputs Second Speed Inputs TertiaryEngine Speed
Engine Parameters
RPM DisconnectOil Disconnect Prelube Period Prelube PauseIdle CoolingAfter Cool PeriodPrestart Period 1Prestart Period 2 Prestart Period 3 Prestart Period 4Crank PeriodCrank PauseCranks AttempsEngine Type Gas RPMGas RPM DelayVent Period Idle PeriodStop PeriodCooling Period
generator Protection
Overload Alarm Overload Warning Overload DelayOver Curr Alarm Over Curr DelayCurrUnbalCurrUnbalDelayIDMTOver Volt AlarmOver Volt WarningUnderVoltWarningUnderVoltAlarmVolt DelayVoltUnbalAlarmVoltUnbalDelayOver Freq AlarmOver Freq WarningUnderFreqWarningUnderFreqAlarmFreq DelayMin Voltage
Setpoints Accessible from the GnS display
protections
GeneratorUnderFrequencyGenerator Over Frequency
GeneratorUnderVoltGenerator Over Volt
GeneratorUnbalancedVoltOver Current
Over Current IDMT UnbalancedCurrent
Over Load UnderSpeedOver Speed Crank Fail Alternator
GCB Fault Discrete Input Fault
Engine Protection
OverspeedLow Fuel Delay Low Fuel WarningLow Fuel AlarmLow Oil P DelayLow Oil P Warning Low Oil P AlarmLow Temp DelayLow Temp Warning Low Temp Alarm HiTempDelayHiTempWarningHiTempAlarmBattery Over VoltBatteryUnderVoltBattery DelayEng Prot DelayServHrsRunHrsAlt Fail Delay
Engine Service BatteryUnderVoltBattery Over Volt Low Fuel Level
Low Oil Pressure Low Engine Temperature HighEngineTemperature
Stop Fail Over Crank
Speed Sensor Fail GCB External Trip AnalogIn1UnderAnalog In 1 Over
AnalogIn2UnderAnalog In 2 Over
AnalogIn3UnderAnalog In 3 Over
AnalogIn4UnderAnalog In 4 Over
Comm Fail Short CircuitConfig Error
Auto Voltage Detect FailureVoltage Phase Wiring Error-GenCurrent Phase Wiring Error-Gen
CAN bus FaultECUOffline
Analog Sender FailureUserDefined1-8
This document is subject to change without notice. Caution: None of GAC products are flight certified controls including this item.
4PTI 4123 D
smartVuThe GNS2000 Series is configured using the accompanying smartVu PC configuration, control and monitoring tool. This program allows the user to set and modify security, operating set points, assign I/O, establish warning and alarm thresholds, and control overall system behavior. Once configured, the settings can be saved to a file for easy replication. While connected to a GNS, smartVu can be used to monitor generator set performance. (see Figure 1.)
Within smartVu, the layout of the display is highly customizable. The user chooses which meters are to be displayed, and the location on the screen. The screen configuration can be stored for later use.
smartVu is capable of simultaneously communicating with multiple GNS controls, and the layout of the screen is customizable.
Figure 1.
Description Keys
9 ButtonStart, Stop, Up, Dow n, Left, Right, Enter, Lap Test, and Horn Reset
11 Button
Start, Stop, Up, Dow n, Left, Right, Enter, Lap Test, Horn Reset, Back (Undo), GCB Open/Close
Control CE UL °C / °F Conformal Coating Mount Display Keypad
-20 to 85 C
-4 to 185 F
-40 to 85 C
-40 to 185 F
-40 to 85 C
-40 to 185 F
-20 to 70 C
-4 to 158 F
-40 to 70 C
-40 to 158 F
-40 to 70 C
-40 to 158 F
11 Button
GNS2004BE Back --- ---
GNS2004E Front64x128
LCD
---
GNS2002E Front64x128
LCD 11 Button
GNS2004B Back ---
9 Button
GNS2004 Front64x128
LCD 9 Button
GNS2002 Front64x128
LCD
Display CE UL °C / °F Conformal Coating Mount Display Keypad
-20 to 85 C
-4 to 185 F
-40 to 85 C
-40 to 185 F
-20 to 70 C
-4 to 158 F
-40 to 70 C
-40 to 158 F
11 Button
GNS2004DE Front64x128
LCD 11 Button
GNS2002DE Front64x128
LCD
9 Button
GNS2004D Front64x128
LCD 9 Button
GNS2002D Front64x128
LCD
gnS Controllers
gnS Keypad Definitions
gnS remote Displays
selectiOn tablesFornon-hostileenvironmentsorapplicationsnotrequiringULapproval,GNSESeriescontrolsandremotedisplaysarelowercostalternatives.
This document is subject to change without notice. Caution: None of GAC products are flight certified controls including this item.
5PTI 4123 D
Figu
re 2
: Sy
stem
Wir
ing
dia
gram
NO
TE:
SIN
GLE
LIN
E B
RE
AK
ER
CO
NTR
OL
W /
NO
FE
ED
BA
CK
SH
OW
N.
18
AWG
RS
-232
3-W
IRE
NU
LL M
OD
EM
CA
BLE
.
4. U
.O.S
. ALL
WIR
ES
TO
BE
22
AWG
.
321
-12
/24V
DC
B
atte
ry
ALT
ER
NAT
OR
2
+
10 a
mp
Fuse
ESTOP
SE
CO
ND
RS
232
PO
RT
(GN
S20
04B
ON
LY)
22 A
WG
TWIS
TED
PAIR
FUEL SOLENOID
PR
ES
TAR
T
2MAGNETIC
REMOTE START/STOP
PICK-UP
STARTER
2
2
LB178-2
FUE
L LE
VE
L
FUE
L S
OLE
NO
ID
STA
RTE
R
DIES
EL/G
AS E
NGIN
E
OIL
PR
ES
SU
RE
EN
GIN
E T
EM
P
GL3
3
WA
RN
ING
CA
NL
SH
ALA
RM
GE
NE
RAT
OR
VO
LTA
GE
1
ON
21
ON
+A
NA
LOG
INP
UTS
-+
-
RS
232/
485
8
OU
TPU
TSB
INA
RY
N9
C6
74
53
+-
-+
21
4 23
NC
BA
LB178-3
FUEL LEVEL
OIL PRESSURE
ENGINE TEMP
N
2
GENE
RATO
R
L1L2
WIR
ING
FO
R D
+ E
XC
ITAT
ION
D+
12/2
4VD
C
Bat
tery
3R
ELA
YS
4
DET
AIL
A
DET
AIL
B
2
RS
485
CA
N
21
ON
1GC
B
RS
485
CA
N
L
TER
MIN
ATIO
N R
ES
ISTO
RS
W. J
UM
PE
RS
W. D
IP S
WIT
CH
ES
LB178-1
GC
UR
RE
NT
GE
NE
RAT
OR
AB
CB
O2RE
LAY
SB
O4
BO
3B
O1
MA
G
9P
/UCN
21
7B
INA
RY
INP
UTS
43
65
8-
8-32
VD
CB
ATTE
RY
+D
+
V B
ATV B
AT
V B
AT
V B
ATV
BAT
V B
AT
V B
AT
HO
RN
V B
AT
V B
AT
Jum
per O
N P
ins
120Ω
Ter
min
atio
n P
rese
nt
Jum
per O
FF P
ins
No
Term
inat
ion
Pre
sent
Sw
itch
ON
Pin
s 12
0Ω T
erm
inat
ion
Pre
sent
Sw
itch
OFF
Pin
s N
o Te
rmin
atio
n P
rese
nt
D+
DE
TAIL
A -
Sw
itcha
ble
term
inat
ion
resi
stor
s fo
r RS
-485
or C
AN
Bus
net
wor
ks th
at
requ
ire te
rmin
atio
n.
DE
TAIL
B -
Con
nect
bat
tery
pos
itive
to o
ne s
ide
of th
e no
rmal
ly o
pen
rela
y an
d th
e ot
her s
ide
to th
e D
+ te
rmin
al o
f the
alte
rnat
or fo
r D+
Exc
itatio
n.
DE
TAIL
C -
If B
inar
y In
put 1
is a
ssig
ned
to E
-Sto
p an
d B
inar
y O
utpu
t 1 is
ass
igne
d Fu
el, b
y de
sign
, ope
ning
the
E-S
top
will
ele
ctro
nica
lly c
ut fu
el to
the
engi
ne.
Rem
ovin
g th
is ju
mpe
r dis
able
s th
e fe
atur
e.
DE
TAIL
D -
E-S
top
Jum
per
DE
TAIL
E -
Dip
switc
hes
for c
onfig
urin
g th
e an
alog
inpu
ts.
The
switc
hes
are
used
on
ly w
hen
conn
ectin
g to
a 4
-20m
A ci
rcui
t.
GN
S200
4B O
NLY
RE
MO
TE S
TAR
T
FAU
LT R
ES
ET
MA
N M
OD
E
OFF
MO
DE
AU
TO M
OD
E
UC
B F
/B (
ALL
GN
S25
00 S
ER
IES
)
GC
B F
/B (
ALL
GN
S25
00 S
ER
IES
)
CN5
BIN
AR
Y IN
PU
TS
12
34
67
98
MA
GP
/U
DET
AIL
C
RE
MO
TE S
TOP
3
ON
124
4-20
mA
INP
UT
ON
OTH
ER
WIS
E O
FF
DET
AIL
E
JUM
PE
R T
O B
RID
GE
INP
UT
1 TO
OU
TPU
T 1
DET
AIL
D
This document is subject to change without notice. Caution: None of GAC products are flight certified controls including this item.
6PTI 4123 D
speciFicatiOns
CommunicationsPC Configuration & Monitoring ................................................. Modbus on RS-232/485ECU................................................................................................................J1939Remote Devices ................................. Modbus on RS-232/485, J1939 on CAN bus
reliabilityTesting....................................................................................100% Functionally Tested
PhysicalOverall Dimensions....................................................................................6” x 9” x 1.75” 152mm x 229mm x 445mmPanel Opening Size...................................................................................4.45” x 6.89” 113mm x 175mmWeight................................................................................................................... 1.3lbs 0.59kgMounting.....................................................................................Front Panel MountedGNS2004B, GNS2004BE..............................................................Back Panel/DIN Rail
smartVu requirementsMicrosoft Windows 2000-Windows Vista...............Pentium II, 64M RAM, 10M Disk VGA, Serial Port
Options
EnvironmentalAmbient Operating Temperature.....................................GNS2004–Temp:-40 to +85°C
GNS2002–Temp:-20 to +85°C
Relative Humidity.........................................................................95% non-condensingAgency Approvals ................................................................. UL2200*,UL508*,CE,CUL*
input ParametersPower .......................................................................................................8VDC-32VDCRide Thru .....................................................................................................0V for 50ms Polarity Negative.................................................................................................GroundSpeed Sensor Signal........................................... 0.5 – 30 Volts RMS, 30-1200 ohms9 Assignable Binary Inputs..............................................................................0-32VDC4 Analog Inputs..................................................Wide range of senders, includingVDO
(e.g.,OilPressure,CoolantTemp) 0-5VDC +/-1.0%,4-20mA +/- 5.0%0-2.4K +/- 5.0 %
0-32mV +/- 1.0 %Generator Voltage......................................................................480VAC RMS Nominal 600VAC Max phase to phase 277VAC RMS Nominal phase to neutral
346VAC RMS Max phase to neutral Accuracy +/- 1%
Generator Current (CT Secondary)..........................................................5A Nominal Accuracy +/- 1%
Output Parameters2 Form A Relay............................................................................................ 30VDC, 3A2 Form C Relay.............................................................................125VAC, 28VDC, 5A5 Binary Outputs...............................................................................0-32VDC,0-500mA
* Non-E Versions Only
• Factory Installed Internal Modem• Remote Displays • EAM Ethernet Adapter• GNS2004B, GNS2004BE
Blackbox • Non-Display Control
• External Modem• Custom Displays (up to 65
LEDs, up to 24 Switches)• Remote Contact Relay Module • Remote Annunciator Panel