Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
www.GenieCompany.com/commercial | 800.843.4084
Wiring DiagramGCL-JSTANDARD-DUTY JACKSHAFT OPERATOR
©2012 The Genie Company
Single PhaSe Wiring Diagram
—
3642
3
O
RIG
INA
L IS
SUE
A
3649
6
C
HA
NG
ED M
OTO
R V
OLT
AG
ES
RJ
S 9
-5-0
8B
36
497
REM
OV
ED O
PTIO
NA
L TR
AN
SFO
RMER
RJS
10-
23-0
8
X
8 PT
C1S
TA
G M
ATER
IAL
WIT
H P
ERM
AN
ENT
AD
HES
IVE.
UV
GLA
ZEK
OTE
FIN
ISH
. SLI
T B
AC
K.
LAB
ELS
SUPP
LIED
FLA
T.
VER
TIC
AL
SLIT
1.2
5” F
RO
M L
EFT
EDG
E
BLA
CK
ON
WH
ITE
RJS
4/07
/08
DEC
AL,
WIR
ING
DIA
GR
AM
, 1 P
HA
SE
15.2
5 X
7.0
1 O
F 1
NTS
B11
1209
.000
1
.25
TYPI
CA
LEX
TRA
BA
CK
ING
15.2
5" +
/- .0
60"
LAB
EL S
IZE
7.00" +/- .060"LABEL SIZE
1-BTNSTATION
KEYSWITCHSTATION
CARD READER
O/C PULLSWITCH
N/O
N/O
N/O
N/O
REMOVE JUMPER WHEN INSTALLING EXTERNAL INTERLOCK
+24VDC
STBENAB
TROUBLESHOOTING LED’s
EXTERNAL WIRING DIAGRAM
+ 24 VOLTSDC
STBENABLE ON = STB ENABLED OFF = STB DISABLED
ON = POWER AVAILABLE OFF = CHECK AC POWER
SUPPLY. CHECK FUSES
GDB - 2.5A ORS500 - 2.5A
EXTERNAL RADIO CONNECTOR
INTERNALRADIO BOARD
BRAKECONNECTOR
CIRCUIT BREAKER (CERTAIN MODELS ONLY)
TRANSFORMERCONNECTORS
SECONDARY FUSE
RADIO FUSE
EXTERNAL ANTENNA CONNECTION
INPUT POWER TERMINALS
HOISTINTERLOCKCONNECTOR
EXPANSIONBOARD PORT
TROUBLE-SHOOTINGLEDs
EXPANSIONMODULEMOUNTINGLOCATIONS
LIMIT SENSOR CONNECTOR
LINEGROUND
TRANSFORMER
CONTROL WIRETERMINALS
ROUTE HIGH VOLTAGE WIRES THROUGH THIS SHADED AREA
ROUTE LOW VOLTAGE WIRES THROUGH THIS SHADED AREA(PLUG UNUSED HOLES)
(PLUG UNUSED HOLES)
MOTORCONNECTORS
GDB - 250 mA ORS504 - 250 mA
(CLASS 2 CONNECTIONS)
(COAX)
LINE INPOWER CONNECTIONS
MULTIPLE 3-BUTTONSTATION INSTALLATIONSREQUIRE THE STOP BUTTON TO BE WIREDIN SERIES. See Fig. 5, pg 5.4
*
L1/ L1 N/ L2
GND
LINE(HOT) NEUTRAL
LINE 1 LINE 2
115V
208/230V
EXTINTLK
EXTINTLK
N-OREVERSE
N-OREVERSE
ODCSTB
ODCSTB
1-BTNGNDSTOPCLOSEOPEN
EXT RADIO CONNECTOR
SENSING EDGE SWITCH
(DO NOT CONNECT 2-WIRE MONITORED SENSING EDGE SWITCH TO THESE INPUTS)
PWR RAD GND GND
THRU-BEAMPHOTOCELLS
+
-
+-
PWR 20-40 VDC @ 250mA MAX CURRENT
RELAY
GNDNOM+ 24VDC
RADIO
SERIES II SAFE-T-BEAM® (STB)
(*CONNECT STB WIRES TO EITHER TERMINAL)
*
OPEN
CLOSE
STOP
REMOVEJUMPERIF STOPBUTTONIS USED
3-BUTTON STATION*
NOT FOR RESIDENTIAL USE
WARNING: FOR CONTINUED PROTECTION AGAINST FIRE, REPLACE FUSES ONLY WITH THE SAME TYPE AND RATING
P/N 111209.0001
208/230V 1PH 115V 1PH
NO
TE:
CIR
CLE
D D
IMEN
SIO
NS
DES
IGN
ATE
CTQ
,(C
RITI
CA
L TO
QU
ALI
TY) S
PEC
IFIC
ATIO
NS
RC
A 9
/8/0
8
RC
A 1
0/24
/08
www.GenieCompany.com/commercial | 800.843.4084
Wiring DiagramGCL-JSTANDARD-DUTY JACKSHAFT OPERATOR
©2012 The Genie Company
Single PhaSe Wiring Diagram
—
3642
3
O
RIG
INA
L IS
SUE
A
3649
6
C
HA
NG
ED M
OTO
R V
OLT
AG
ES
RJ
S 9
-5-0
8B
36
497
REM
OV
ED O
PTIO
NA
L TR
AN
SFO
RMER
RJS
10-
23-0
8
X
8 PT
C1S
TA
G M
ATER
IAL
WIT
H P
ERM
AN
ENT
AD
HES
IVE.
UV
GLA
ZEK
OTE
FIN
ISH
. SLI
T B
AC
K.
LAB
ELS
SUPP
LIED
FLA
T.
VER
TIC
AL
SLIT
1.2
5” F
RO
M L
EFT
EDG
E
BLA
CK
ON
WH
ITE
RJS
4/07
/08
DEC
AL,
WIR
ING
DIA
GR
AM
, 1 P
HA
SE
15.2
5 X
7.0
1 O
F 1
NTS
B11
1209
.000
1
.25
TYPI
CA
LEX
TRA
BA
CK
ING
15.2
5" +
/- .0
60"
LAB
EL S
IZE
7.00" +/- .060"LABEL SIZE
1-BTNSTATION
KEYSWITCHSTATION
CARD READER
O/C PULLSWITCH
N/O
N/O
N/O
N/O
REMOVE JUMPER WHEN INSTALLING EXTERNAL INTERLOCK
+24VDC
STBENAB
TROUBLESHOOTING LED’s
EXTERNAL WIRING DIAGRAM
+ 24 VOLTSDC
STBENABLE ON = STB ENABLED OFF = STB DISABLED
ON = POWER AVAILABLE OFF = CHECK AC POWER
SUPPLY. CHECK FUSES
GDB - 2.5A ORS500 - 2.5A
EXTERNAL RADIO CONNECTOR
INTERNALRADIO BOARD
BRAKECONNECTOR
CIRCUIT BREAKER (CERTAIN MODELS ONLY)
TRANSFORMERCONNECTORS
SECONDARY FUSE
RADIO FUSE
EXTERNAL ANTENNA CONNECTION
INPUT POWER TERMINALS
HOISTINTERLOCKCONNECTOR
EXPANSIONBOARD PORT
TROUBLE-SHOOTINGLEDs
EXPANSIONMODULEMOUNTINGLOCATIONS
LIMIT SENSOR CONNECTOR
LINEGROUND
TRANSFORMER
CONTROL WIRETERMINALS
ROUTE HIGH VOLTAGE WIRES THROUGH THIS SHADED AREA
ROUTE LOW VOLTAGE WIRES THROUGH THIS SHADED AREA(PLUG UNUSED HOLES)
(PLUG UNUSED HOLES)
MOTORCONNECTORS
GDB - 250 mA ORS504 - 250 mA
(CLASS 2 CONNECTIONS)
(COAX)
LINE INPOWER CONNECTIONS
MULTIPLE 3-BUTTONSTATION INSTALLATIONSREQUIRE THE STOP BUTTON TO BE WIREDIN SERIES. See Fig. 5, pg 5.4
*
L1/ L1 N/ L2
GND
LINE(HOT) NEUTRAL
LINE 1 LINE 2
115V
208/230V
EXTINTLK
EXTINTLK
N-OREVERSE
N-OREVERSE
ODCSTB
ODCSTB
1-BTNGNDSTOPCLOSEOPEN
EXT RADIO CONNECTOR
SENSING EDGE SWITCH
(DO NOT CONNECT 2-WIRE MONITORED SENSING EDGE SWITCH TO THESE INPUTS)
PWR RAD GND GND
THRU-BEAMPHOTOCELLS
+
-
+-
PWR 20-40 VDC @ 250mA MAX CURRENT
RELAY
GNDNOM+ 24VDC
RADIO
SERIES II SAFE-T-BEAM® (STB)
(*CONNECT STB WIRES TO EITHER TERMINAL)
*
OPEN
CLOSE
STOP
REMOVEJUMPERIF STOPBUTTONIS USED
3-BUTTON STATION*
NOT FOR RESIDENTIAL USE
WARNING: FOR CONTINUED PROTECTION AGAINST FIRE, REPLACE FUSES ONLY WITH THE SAME TYPE AND RATING
P/N 111209.0001
208/230V 1PH 115V 1PH
NO
TE:
CIR
CLE
D D
IMEN
SIO
NS
DES
IGN
ATE
CTQ
,(C
RITI
CA
L TO
QU
ALI
TY) S
PEC
IFIC
ATIO
NS
RC
A 9
/8/0
8
RC
A 1
0/24
/08
www.GenieCompany.com/commercial | 800.843.4084
Wiring DiagramGCL-JSTANDARD-DUTY JACKSHAFT OPERATOR
©2012 The Genie Company
Three PhaSe Wiring Diagram
—
3642
3
O
RIG
INA
L IS
SUE
A
3649
6
C
HA
NG
ED M
OTO
R V
OLT
AG
ES
RJ
S 9-
5-08
X
8 PT
C1S
TA
G M
ATER
IAL
WIT
H P
ERM
AN
ENT
AD
HES
IVE.
UV
GLA
ZEK
OTE
FIN
ISH
. SLI
T B
AC
K.
LAB
ELS
SUPP
LIED
FLA
T.
VER
TIC
AL
SLIT
1.2
5” F
RO
M L
EFT
EDG
E
BLA
CK
ON
WH
ITE
RJS
DEC
AL,
WIR
ING
DIA
GR
AM
, 3 P
HA
SE
15.2
5 X
7.0
1 O
F 1
NTS
B11
1281
.000
1
15.2
5" +
/- .0
60"
LAB
EL S
IZE
7.00" +/- .060"LABEL SIZE
.25
TYPI
CA
LEX
TRA
BA
CK
ING
+24VDC
STBENAB
TROUBLESHOOTING LED’s
+ 24 VOLTSDC
STBENABLE ON = STB ENABLED OFF = STB DISABLED
ON = POWER AVAILABLE OFF = CHECK AC POWER
SUPPLY. CHECK FUSES
GDB - 2.5A orS500 - 2.5A
EXTERNAL RADIO CONNECTOR
BRAKECONNECTOR
SECONDARY FUSE
RADIO FUSE
EXTERNAL ANTENNACONNECTION
HOISTINTERLOCKCONNECTOR
EXPANSIONBOARD PORT
LIMIT SENSOR CONNECTOR
LINEGROUND
TRANSFORMER
CONTROL WIRETERMINALS
ROUTE HIGH VOLTAGE WIRES THROUGH THIS SHADED AREA
ROUTE LOW VOLTAGE WIRES THROUGH THIS SHADED AREA
MOTORCONNECTORS
208/230V 3PH 460V 3PH
GDB - 250 mA ORS504 - 250 mA
(COAX)
TRANSFORMERCONNECTORS
INPUT POWER TERMINALS
INTERNALRADIO BOARD
LINE INPOWER CONNECTIONS
L1 L2 GND
LINE 1 LINE 2 LINE 3
L3
(PLUG UNUSED HOLES)
(PLUG UNUSED HOLES)
NOT FOR RESIDENTIAL USE
1-BTNSTATION
KEYSWITCHSTATION
CARD READER
O/C PULLSWITCH
N/O
N/O
N/O
N/O
REMOVE JUMPER WHEN INSTALLING EXTERNAL INTERLOCK
EXTERNAL WIRING DIAGRAM
MULTIPLE 3-BUTTONSTATION INSTALLATIONSREQUIRE THE STOP BUTTON TO BE WIREDIN SERIES. See Fig. 5, pg 5.4
*
EXTINTLK
EXTINTLK
N-OREVERSE
N-OREVERSE
ODCSTB
ODCSTB
1-BTNGNDSTOPCLOSEOPEN
EXT RADIO CONNECTOR
SENSING EDGE SWITCH
(DO NOT CONNECT 2-WIRE MONITORED SENSING EDGE SWITCH TO THESE INPUTS)
PWR RAD GND GND
THRU-BEAMPHOTOCELLS
+
-
+-
PWR 20-40 VDC @ 250mA MAX CURRENT
RELAY
GNDNOM+ 24VDC
RADIO
SERIES II SAFE-T-BEAM® (STB)
(*CONNECT STB WIRES TO EITHER TERMINAL)
*
OPEN
CLOSE
STOP
REMOVEJUMPERIF STOPBUTTONIS USED
3-BUTTON STATION*
WARNING: FOR CONTINUED PROTECTION AGAINST FIRE, REPLACE FUSES ONLY WITH THE SAME TYPE AND RATING
P/N 111281.0001
EXPANSIONMODULEMOUNTINGLOCATIONS
TROUBLE-SHOOTINGLEDs
NO
TE:
CIR
CLE
D D
IMEN
SIO
NS
DES
IGN
ATE
CTQ
,(C
RITI
CA
L TO
QU
ALI
TY) S
PEC
IFIC
ATIO
NS
L1 L2 L3
208/230—460V
RC
A
B
3649
7
RE
MO
VED
OPT
ION
AL
TRA
NSF
ORM
ER
RJ
S 1
0-23
-08
4/07
/08
9/8
/08
RC
A 1
0/24
/08
www.GenieCompany.com/commercial | 800.843.4084
Wiring DiagramGCL-JSTANDARD-DUTY JACKSHAFT OPERATOR
©2012 The Genie Company
Three PhaSe Wiring Diagram
—
3642
3
O
RIG
INA
L IS
SUE
A
3649
6
C
HA
NG
ED M
OTO
R V
OLT
AG
ES
RJ
S 9-
5-08
X
8 PT
C1S
TA
G M
ATER
IAL
WIT
H P
ERM
AN
ENT
AD
HES
IVE.
UV
GLA
ZEK
OTE
FIN
ISH
. SLI
T B
AC
K.
LAB
ELS
SUPP
LIED
FLA
T.
VER
TIC
AL
SLIT
1.2
5” F
RO
M L
EFT
EDG
E
BLA
CK
ON
WH
ITE
RJS
DEC
AL,
WIR
ING
DIA
GR
AM
, 3 P
HA
SE
15.2
5 X
7.0
1 O
F 1
NTS
B11
1281
.000
1
15.2
5" +
/- .0
60"
LAB
EL S
IZE
7.00" +/- .060"LABEL SIZE
.25
TYPI
CA
LEX
TRA
BA
CK
ING
+24VDC
STBENAB
TROUBLESHOOTING LED’s
+ 24 VOLTSDC
STBENABLE ON = STB ENABLED OFF = STB DISABLED
ON = POWER AVAILABLE OFF = CHECK AC POWER
SUPPLY. CHECK FUSES
GDB - 2.5A orS500 - 2.5A
EXTERNAL RADIO CONNECTOR
BRAKECONNECTOR
SECONDARY FUSE
RADIO FUSE
EXTERNAL ANTENNACONNECTION
HOISTINTERLOCKCONNECTOR
EXPANSIONBOARD PORT
LIMIT SENSOR CONNECTOR
LINEGROUND
TRANSFORMER
CONTROL WIRETERMINALS
ROUTE HIGH VOLTAGE WIRES THROUGH THIS SHADED AREA
ROUTE LOW VOLTAGE WIRES THROUGH THIS SHADED AREA
MOTORCONNECTORS
208/230V 3PH 460V 3PH
GDB - 250 mA ORS504 - 250 mA
(COAX)
TRANSFORMERCONNECTORS
INPUT POWER TERMINALS
INTERNALRADIO BOARD
LINE INPOWER CONNECTIONS
L1 L2 GND
LINE 1 LINE 2 LINE 3
L3
(PLUG UNUSED HOLES)
(PLUG UNUSED HOLES)
NOT FOR RESIDENTIAL USE
1-BTNSTATION
KEYSWITCHSTATION
CARD READER
O/C PULLSWITCH
N/O
N/O
N/O
N/O
REMOVE JUMPER WHEN INSTALLING EXTERNAL INTERLOCK
EXTERNAL WIRING DIAGRAM
MULTIPLE 3-BUTTONSTATION INSTALLATIONSREQUIRE THE STOP BUTTON TO BE WIREDIN SERIES. See Fig. 5, pg 5.4
*
EXTINTLK
EXTINTLK
N-OREVERSE
N-OREVERSE
ODCSTB
ODCSTB
1-BTNGNDSTOPCLOSEOPEN
EXT RADIO CONNECTOR
SENSING EDGE SWITCH
(DO NOT CONNECT 2-WIRE MONITORED SENSING EDGE SWITCH TO THESE INPUTS)
PWR RAD GND GND
THRU-BEAMPHOTOCELLS
+
-
+-
PWR 20-40 VDC @ 250mA MAX CURRENT
RELAY
GNDNOM+ 24VDC
RADIO
SERIES II SAFE-T-BEAM® (STB)
(*CONNECT STB WIRES TO EITHER TERMINAL)
*
OPEN
CLOSE
STOP
REMOVEJUMPERIF STOPBUTTONIS USED
3-BUTTON STATION*
WARNING: FOR CONTINUED PROTECTION AGAINST FIRE, REPLACE FUSES ONLY WITH THE SAME TYPE AND RATING
P/N 111281.0001
EXPANSIONMODULEMOUNTINGLOCATIONS
TROUBLE-SHOOTINGLEDs
NO
TE:
CIR
CLE
D D
IMEN
SIO
NS
DES
IGN
ATE
CTQ
,(C
RITI
CA
L TO
QU
ALI
TY) S
PEC
IFIC
ATIO
NS
L1 L2 L3
208/230—460V
RC
A
B
3649
7
RE
MO
VED
OPT
ION
AL
TRA
NSF
ORM
ER
RJ
S 1
0-23
-08
4/07
/08
9/8
/08
RC
A 1
0/24
/08
www.GenieCompany.com/commercial | 800.843.4084
Wiring DiagramGCL-JSTANDARD-DUTY JACKSHAFT OPERATOR
©2012 The Genie Company
575 VolT PhaSe Wiring Diagram
—
3642
3
O
RIG
INA
L IS
SUE
X
8 PT
C1S
TA
G M
ATER
IAL
WIT
H P
ERM
AN
ENT
AD
HES
IVE.
UV
GLA
ZEK
OTE
FIN
ISH
. SLI
T B
AC
K.
LAB
ELS
SUPP
LIED
FLA
T.
VER
TIC
AL
SLIT
1.2
5” F
RO
M L
EFT
EDG
E
BLA
CK
ON
WH
ITE
RJS
RC
AD
ECA
L, W
IRIN
GD
IAG
RA
M, 5
75V
15.2
5 X
7.0
1 O
F 1
NTS
B11
1379
.000
1
.25
TYPI
CA
LEX
TRA
BA
CK
ING
15.2
5" +
/- .0
60"
LAB
EL S
IZE
7.00" +/- .060"LABEL SIZE
+24VDC
STBENAB
TROUBLESHOOTING LED’s
+ 24 VOLTSDC
STBENABLE ON = STB ENABLED OFF = STB DISABLED
ON = POWER AVAILABLE OFF = CHECK AC POWER
SUPPLY. CHECK FUSES
GDB - 2.5A orS500 - 2.5A
EXTERNAL RADIO CONNECTOR
BRAKECONNECTOR
SECONDARY FUSE
RADIO FUSE
EXTERNAL ANTENNACONNECTION
HOISTINTERLOCKCONNECTOR
EXPANSIONBOARD PORT
LIMIT SENSOR CONNECTOR
LINEGROUND
TRANSFORMER
CONTROL WIRETERMINALS
ROUTE HIGH VOLTAGE WIRES THROUGH THIS SHADED AREA
ROUTE LOW VOLTAGE WIRES THROUGH THIS SHADED AREA
MOTORCONNECTOR
575V 3PH
GDB - 250 mA ORS504 - 250 mA
(COAX)
TRANSFORMERCONNECTORS
INPUT POWER TERMINALS
INTERNALRADIO BOARD
LINE INPOWER CONNECTIONS
L1 L2 GND
LINE 1 LINE 2 LINE 3
L3
(PLUG UNUSED HOLES)
(PLUG UNUSED HOLES)
NOT FOR RESIDENTIAL USE
1-BTNSTATION
KEYSWITCHSTATION
CARD READER
O/C PULLSWITCH
N/O
N/O
N/O
N/O
REMOVE JUMPER WHEN INSTALLING EXTERNAL INTERLOCK
EXTERNAL WIRING DIAGRAM
MULTIPLE 3-BUTTONSTATION INSTALLATIONSREQUIRE THE STOP BUTTON TO BE WIREDIN SERIES. See Fig. 5, pg 5.4
*
EXTINTLK
EXTINTLK
N-OREVERSE
N-OREVERSE
ODCSTB
ODCSTB
1-BTNGNDSTOPCLOSEOPEN
EXT RADIO CONNECTOR
SENSING EDGE SWITCH
(DO NOT CONNECT 2-WIRE MONITORED SENSING EDGE SWITCH TO THESE INPUTS)
PWR RAD GND GND
THRU-BEAMPHOTOCELLS
+
-
+-
PWR 20-40 VDC @ 250mA MAX CURRENT
RELAY
GNDNOM+ 24VDC
RADIO
SERIES II SAFE-T-BEAM® (STB)
(*CONNECT STB WIRES TO EITHER TERMINAL)
*
OPEN
CLOSE
STOP
REMOVEJUMPERIF STOPBUTTONIS USED
3-BUTTON STATION*
WARNING: FOR CONTINUED PROTECTION AGAINST FIRE, REPLACE FUSES ONLY WITH THE SAME TYPE AND RATING
P/N 111379.0001
EXPANSIONMODULEMOUNTINGLOCATIONS
TROUBLE-SHOOTINGLEDs
L1 L2 L3
NO
TE:
CIR
CLE
D D
IMEN
SIO
NS
DES
IGN
ATE
CTQ
,(C
RITI
CA
L TO
QU
ALI
TY) S
PEC
IFIC
ATIO
NS
575V
A
3649
7
RE
MO
VED
OPT
ION
AL
TRA
NSF
ORM
ER
RJ
S 1
0-23
-08
4/07
/08
9/8
/08
RC
A 1
0/24
/08
www.GenieCompany.com/commercial | 800.843.4084
Wiring DiagramGCL-JSTANDARD-DUTY JACKSHAFT OPERATOR
©2012 The Genie Company
575 VolT PhaSe Wiring Diagram
—
3642
3
O
RIG
INA
L IS
SUE
X
8 PT
C1S
TA
G M
ATER
IAL
WIT
H P
ERM
AN
ENT
AD
HES
IVE.
UV
GLA
ZEK
OTE
FIN
ISH
. SLI
T B
AC
K.
LAB
ELS
SUPP
LIED
FLA
T.
VER
TIC
AL
SLIT
1.2
5” F
RO
M L
EFT
EDG
E
BLA
CK
ON
WH
ITE
RJS
RC
AD
ECA
L, W
IRIN
GD
IAG
RA
M, 5
75V
15.2
5 X
7.0
1 O
F 1
NTS
B11
1379
.000
1
.25
TYPI
CA
LEX
TRA
BA
CK
ING
15.2
5" +
/- .0
60"
LAB
EL S
IZE
7.00" +/- .060"LABEL SIZE
+24VDC
STBENAB
TROUBLESHOOTING LED’s
+ 24 VOLTSDC
STBENABLE ON = STB ENABLED OFF = STB DISABLED
ON = POWER AVAILABLE OFF = CHECK AC POWER
SUPPLY. CHECK FUSES
GDB - 2.5A orS500 - 2.5A
EXTERNAL RADIO CONNECTOR
BRAKECONNECTOR
SECONDARY FUSE
RADIO FUSE
EXTERNAL ANTENNACONNECTION
HOISTINTERLOCKCONNECTOR
EXPANSIONBOARD PORT
LIMIT SENSOR CONNECTOR
LINEGROUND
TRANSFORMER
CONTROL WIRETERMINALS
ROUTE HIGH VOLTAGE WIRES THROUGH THIS SHADED AREA
ROUTE LOW VOLTAGE WIRES THROUGH THIS SHADED AREA
MOTORCONNECTOR
575V 3PH
GDB - 250 mA ORS504 - 250 mA
(COAX)
TRANSFORMERCONNECTORS
INPUT POWER TERMINALS
INTERNALRADIO BOARD
LINE INPOWER CONNECTIONS
L1 L2 GND
LINE 1 LINE 2 LINE 3
L3
(PLUG UNUSED HOLES)
(PLUG UNUSED HOLES)
NOT FOR RESIDENTIAL USE
1-BTNSTATION
KEYSWITCHSTATION
CARD READER
O/C PULLSWITCH
N/O
N/O
N/O
N/O
REMOVE JUMPER WHEN INSTALLING EXTERNAL INTERLOCK
EXTERNAL WIRING DIAGRAM
MULTIPLE 3-BUTTONSTATION INSTALLATIONSREQUIRE THE STOP BUTTON TO BE WIREDIN SERIES. See Fig. 5, pg 5.4
*
EXTINTLK
EXTINTLK
N-OREVERSE
N-OREVERSE
ODCSTB
ODCSTB
1-BTNGNDSTOPCLOSEOPEN
EXT RADIO CONNECTOR
SENSING EDGE SWITCH
(DO NOT CONNECT 2-WIRE MONITORED SENSING EDGE SWITCH TO THESE INPUTS)
PWR RAD GND GND
THRU-BEAMPHOTOCELLS
+
-
+-
PWR 20-40 VDC @ 250mA MAX CURRENT
RELAY
GNDNOM+ 24VDC
RADIO
SERIES II SAFE-T-BEAM® (STB)
(*CONNECT STB WIRES TO EITHER TERMINAL)
*
OPEN
CLOSE
STOP
REMOVEJUMPERIF STOPBUTTONIS USED
3-BUTTON STATION*
WARNING: FOR CONTINUED PROTECTION AGAINST FIRE, REPLACE FUSES ONLY WITH THE SAME TYPE AND RATING
P/N 111379.0001
EXPANSIONMODULEMOUNTINGLOCATIONS
TROUBLE-SHOOTINGLEDs
L1 L2 L3
NO
TE:
CIR
CLE
D D
IMEN
SIO
NS
DES
IGN
ATE
CTQ
,(C
RITI
CA
L TO
QU
ALI
TY) S
PEC
IFIC
ATIO
NS
575V
A
3649
7
RE
MO
VED
OPT
ION
AL
TRA
NSF
ORM
ER
RJ
S 1
0-23
-08
4/07
/08
9/8
/08
RC
A 1
0/24
/08