Upload
vunhan
View
238
Download
0
Embed Size (px)
Citation preview
STROOMAGGREGAATGE 65 PSX EAS - GE 65 PMSX EASSTROOMAGGREGAATGE 65 PSX EAS - GE 65 PMSX EAS
ISO 9001:2000 - Cert. 0192
PERKINS watergekoelde dieselmotor - 1500 rpmEP6 motorbeveiligingGE 65 PSX – STAMFORD driefase synchrone generatorGE 65 PMSX – MARELLI driefase synchrone generatorElectronische voltregeling4 polige hoofdschakelaarSuper geluidgedemptLekbakOnderstel (optie)Voorbereid voor noodstroom / start-stop op afstandRobuuste, stille machine
ISO 9001:2000 - Cert. 0192
Dieselengine
EP6Standaarduitrusting
rpm
[OIL] [°C] [Hi H] [bELt][FUEL]
AVR 3 x3 x
4-stroke diesel, turbocharged, direct injection, water cooled
PERKINS 1104C-44TG359.3 kW (80.6 HP)53.7 kW (73 HP)3/ 4.4 l (4400 cm )1500 rpm11.9 l/h (214 g/kWh)
102 l8.5 hIP 442490x1030x14801280 kg91 dB(A) (66 dB(A) @ 7 m)92 dB(A) (67 dB(A) @ 7 m)
3
66 kVA (52.8 kW) / 400 V / 95.2 A60 kVA (48 kW) / 400 V / 86.6 A22 kVA / 230 V / 95.6 A0.8H
GE 65 PMSX EASThree-phase syncronous alternator, self-excited, self-regulated, brushless
MOSA Aggregaten B.V. - Watermolen 4b - 4751 VK Oud Gastel tel 0165-518672 fax 0165-518682 www.mosa-aggregaten.nl
Model- en specificatiewijzigingen voorbehouden10/09
II2000 / 14 / CE
97/68/CEStage II
InterruttoreStart local /
Remote
84065ZI
Battery12V
Centrallifting eye
Fuel levelgauge
Battery charge
indicatorElectric Starter
Engineprotection
low press.shut down
Fuel levelgauge /low
fuel indicatorWatercooling
Ready forEAS/TCM
Synchronousalternator
Voltmeter
CircuitBreaker
Frequency-meter
SirenEmergencystop button
BatteryVoltmeter
Hours-meterRpm-meter
Voltmeterphase selector
AutomaticVoltage
RegulatorTerminal
blockAmmeter
Remote start
low fuelShut down
high watershut down
Opt
ies
af fa
brie
k
Electrical panel with sockets :1x400V 125A 3P+N+T CEE - 1x400V 63A 3P+N+T CEE - 1x400V 32A 3P+N+T CEE - 1x400V 16A 3P+N+T CEE - 2 x 230V 16A 2P+T CEE
Fuel tank 120lFuel tank 350l3-way valve fuel system with quickconnection for external fuel tank feeding
Volt and Hz adjustable from control panelGauges – water temperature and oil pressureWater heater WHAutomatic fuel transfer pump
50/60 Hz SelectorELR-Earth Leakage Relay (GFI)Isometer (Insulation monitors)Radio-controlPermanent Magnet Generator
The electrical panel requires an electrical protection : ELR-Earth Leakage Relay (GFI) or Isometer (Insulation monitors)
Opties 400 plugs230 plugs
Automatic transfer unit (AMF) EAS 76-805Remote control TCM35
Earthing kitSite tow CTL35
24 hautonomyversion
Uitvoeringop verzoek
Adjustable site tow CTLR35
Technische gegevens
* Stand-by three-phase power* P.R.P. three-phase power* P.R.P. single-phase powerCosInsulation class
Model* Stand-By net power* P.R.P. net powerCylinders/ DisplacementSpeedFuel consumption (75% of P.R.P.)
Tank capacityRunning time (75% of P.R.P.)IP protection degree*Dimensions LxWxh (mm)*Dry weight**Measured acoustic power LwA (pressure LpA)**Guaranteed acoustic power LwA (pressure LpA)
*Output powers according to ISO 8528-1
* Powers according to ISO 3046-1
* Dimensions and weight without trolley/trailer. ** Acoustic power according to European Directive 2000/14/EC
MOTOR
ALGEMENE SPECIFICATIES
A.C GENERATOR – 50 Hz