Upload
others
View
5
Download
0
Embed Size (px)
Citation preview
safe - timeless - beautiful
199
markiluxFitting
Accessories
Technical Information
Optional Accessories
markilux75
markilux790
markilux1300 stretch
markilux1300
markilux1100
markilux1000 stretch
markilux1000
markilux930 swing
markilux1650
markilux1600 pavilion 2
markilux1600 stretch
markilux1600
markilux1550
markilux1500
markilux 1200 stretch
markilux1200
markilux990
markilux3300 /
3300 pur
markilux5010
markilux6000
markiluxES-1
Specifi cation
markilux Collection
General Information
Unique design, classic arm technology
markilux 1600
200
Additional featuresTechnical highlightsDesign features
markilux 1600
• the Shadeplus creates an additional room on the patio. protection from the sun, the wind and inquisitive glances all in one
• radio-controlled motor with radio remote control for ease of use
• hard-wired motor operation (optionally with automatic weather controls) for straightforward and easy operation
• in the case of manual operation ease of use is ensured with the spring-assisted gearbox
• wall sealing profi le to cover the gap between awning and wall
• available with a valance
• awning available in non-standard RAL colours
• the extremely sturdy awning construction makes it possible to shade even very large areas safely
• sturdy, round steel torque bar, 50 mm ∅, to prevent twist and defl ection
• coverboard with integrated brush, so that larger pieces of dirt and debris cannot be drawn into the awning
• the 85 mm roller tube ensures the highest stiffness and the best possible cover winding characteristics even at the largest widths
• folding arms with perfected power transference by means of twin, steel-link chains and direct coupling of the springs. maximum safety even in the case of large projections
• folding-arm awning in a semi-cassette version. the dynamically rounded coverboard gives the awning the appearance of being a full cassette
• presented with the IF Design Award for excellent design
• elegant and robust front profi le made of aluminium with valance slot
Unique design, classic arm technology
markilux 1600
201
Standard specification Standard frame colours Optional accessories
www.markilux.com
Fitting Accessories
Technical Information
Optional Accessories
markilux75
markilux790
markilux1300 stretch
markilux1300
markilux1100
markilux1000 stretch
markilux1000
markilux930 swing
markilux1650
markilux1600 pavilion 2
markilux1600 stretch
markilux1600
markilux1550
markilux1500
markilux 1200 stretch
markilux1200
markilux990
markilux3300 /
3300 pur
markilux5010
markilux6000
markiluxES-1
Specification
markilux Collection
General Information
markilux 1600
hard-wired or radio-controlled motor with remote control
Shadeplus
wall sealing profile
light and wind sensor
infra-red heater
valance
Vibrabox / Sunis light sensor
non-standard powder-coated finish
traffic white - RAL 9016
metallic aluminium - RAL 9006
grey brown - similar to RAL 8019
light ivory - RAL 1015
off-white textured finish - 5233
stone grey metallic - 5215
anthracite metallic - 5204
manual operation with stainless steel winding handle
bonded awning cover
sunsilk snc fabric
sunsilk snc signature fabric
acrylic fabric 34
widely woven acrylic fabric
PVC fabric
side view with manual operation (illustration without winding handle)
pitch adjustment via the fixture brackets
wall sealing profile (optional), effective up to a pitch of 15°
side view with awning retracted, top fixture
corrosion-resistant and technically proven; twin steel-link chains at the elbow joints
Shadeplus / drop valance (optional) during extension
side view at a pitch of 50°
side view with awning retracted, face fixture
Lounge style line
202
markilux 1600
anthracite metallic
stone grey metallic
off-white textured fi nish
off-white textured fi nish - 5233
stone grey metallic - 5215
anthracite metallic - 5204
Frame colours
polished chrome
End caps alternatively in
Dimensions and configuration options
203Fitting
Accessories
Technical Information
Optional Accessories
markilux75
markilux790
markilux1300 stretch
markilux1300
markilux1100
markilux1000 stretch
markilux1000
markilux930 swing
markilux1650
markilux1600 pavilion 2
markilux1600 stretch
markilux1600
markilux1550
markilux1500
markilux 1200 stretch
markilux1200
markilux990
markilux3300 /
3300 pur
markilux5010
markilux6000
markiluxES-1
Specification
markilux Collection
General Information
markilux 1600
* Colours similar to the RAL chart - these may differ slightly from those depicted in both hue and finish.
Frame colourstraffic white - RAL 9016 ●metallic aluminium - RAL 9006 ●grey brown - similar to RAL 8019 ●light ivory - RAL 1015 ●off-white textured finish - 5233 (Lounge) ●nano stone grey metallic - 5215 (Lounge) ●anthracite metallic - 5204 (Lounge) ●non-standard powder-coated finish ○
● = standard specification○ = optional accessories– = not available○* = radio-controlled motor using 433 MHz technology●1 = available up to a max. projection of 300 cm, not possible in those
dimensions that require a rolltex bearing ○2 = up to a maximum projection of 250 cm, up to a maximum width of 610 cm●3 = up to a maximum projection of 250 cm, up to a maximum width of 610 cm○4 = wall sealing profile effective up to a maximum awning pitch of 15° ○5 = for minimum widths please consult the "Technical Information" section ○6 = please see bracket fixture range
Operationmanual operation with stainless steel winding handle ●servo-assisted operation ○hard-wired motor ○radio-controlled motor ○*
Shadeplusmanual operation ○hard-wired motor ○radio-controlled motor ○*
Lightinghalogen spotlights –
Coverssunsilk snc (fabric series 324xx/329xx) ●sunsilk snc signature (fabric series 369xx) ●acrylic 34 (fabric series 341xx-347xx) ●widely woven acrylic (fabric series 349xx) ●1
sunsilk perla FR (fabric series 374xx/379xx) ○transolair (fabric series 339xx) –Soltis 92 ○2
PVC fabric ●3
Miscellaneouscoverboard –system coverboard –wall sealing profile ○4
pitch adjustment gear –insertable side blind ○light and wind sensor ○valance ○infra-red heater ○Vibrabox / Sunis light sensor ○
Coupled unitscoupled unit, 2 fields ○5
coupled unit, 3 fields –junction roller ○6
one-piece cover (on request) –
The width of the awning cover is always less than the width of the awning. Coupled units on request.
Pitch adjustment range: from 5° to 50° (to the horizontal).
Definition of the projection: Please consult the section "Technical Information".
In the case of manual operation approximately 16 winding handle revolutions can be assumed per metre of awning projection.
It takes approximately 12 seconds per metre to extend a motor-driven awning.
Definition of shadeplus drop: The shadeplus drop is measured from the bottom edge of the shadeplus profile to the bottom edge of the valance profile. Due to fabric thickness tolerances the actual drop may be shorter than the nominal drop by up to 5 cm. For the maximum shadeplus drops please consult the section "Technical Information".
A shadeplus is not available with a PVC cover.
Coupled folding-arm awnings are available up to a max. of 2 single units side by side, however only with a motor.
A coupled unit is available with junction roller. Pattern repeat mismatches are possible in the case of junction roller covers. A junction roller may not fit when the projection is the maximum for the width of each awning. (see also the section on "Installation", the arm separation table).
If coupled blinds are fitted into a recess or reveal the overall width of the coupled awning must be at least 6 cm less than the width of the opening to allow the awning to be coupled. Make a special note if an awning is to be fitted into a recess or reveal and note the recess/reveal dimensions separately on the order.
= available, 3 folding arms, 2 rolltex bearings
= available, 2 folding arms, 1 rolltex bearing
= available, 2 folding arms1) the dimensions are only valid for fixture without spreader plates (2 folding arms) 2) a shadeplus is not possible 3) awnings with 4 m extension are only available with motor (surcharge) 4) awnings with 3 arms are only available with motor (surcharge) 5) please note the minimum widths!
awning width minimum widthsmotor operation ¹⁾ manual operation ¹⁾
projection 260 310 360 410 460 510 560 610 660 7104) 2 folding arms 3 folding arms 2 folding arms
174-260 261-310 311-360 361-410 411-460 461-510 511-560 561-610 611-660 661-710 standard bespoke arms standard standard bespoke arms
150 5) 187 174 661 190 177
200 5) 237 224 661 240 227
250 5) 287 274 661 290 277
300 5) 337 324 661 340 327
350 5) 2) 387 374 661 390 377
4002⁾ 3⁾ 5) 437 424 687 --- ---
dimensions in cm
Housing tolerances / Awning cover dimensions width projection
housing tolerance +5 / -15 awning cover width = width less 260awning cover length = awning projection plus 180
dimensions in mm
Fixtures, fittings and accessories
. = Please insert the RAL No. (please refer to the section on "Coatings")
204
markilux 1600
Face fixture bracket assembly
45 Face fixture bracket assembly
Top fixture bracket assembly
100 mm 45 mm 90 mm
70867. 71813. 70868.
45 Top fixture bracket assembly
Top fixture bracket assembly
Eaves fixture bracket assembly
45 mm for central fixture 90 mm
complete set
71818. 70869. 70871.
140 90
150 Eaves fixture bracket
90150
270
Eaves fixture bracket assembly
Spreader plate A (including bracket bolts)
150 mm 270 mm 160 x 430 x 12 mm
71612. 71659. 75326.Spreader plate B Flat plate and angled
bracket for eaves fixtureAdditional eaves fixture plate assembly
300 x 400 x 12 mm machine finish 60 x 260 x 12 mm
75325. 716620 75383.Spacer plate for face fixture
100 x 150 x 20 mm
N.B.! stack to a max. of 200 mm
Spacer plate for face fixture
Spacer plate for face fixture
45 x 150 x 20 mm
N.B.! stack to a max. of 200 mm100 x 150 x 12 mm
(please refer to the section "Technical Information")
(please refer to the section "Technical Information")
(please refer to the section "Technical Information")
718231 718241 718251Spacer plate for face fixture
Spacer plate for top fixture
90 x 140 x 20 mm
N.B.! stack to a max. of 200 mm
Spacer plate for top fixture
45 x 150 x 12 mm 90 x 140 x 12 mm
(please refer to the section "Technical Information")
(please refer to the section "Technical Information")
(please refer to the section "Technical Information")
71826. 716311 716411Spacer plate for top fixture
45 x 140 x 20 mm
N.B.! stack to a max. of 200 mm
Spacer plate for top fixture 170
170
80 -300Spacer bracket for face fixture bracket 71813.
45 x 140 x 12 mm
(please refer to the section "Technical Information")
(please refer to the section "Technical Information")
(please refer to the section "Technical Information")
716261 716371 77967.190
170
80 -300Spacer bracket for face fixture bracket 70867.
230
210
Cover plate for installation with spacer plates and spacer brackets in the case of external insulation
210
230
Cover plate for installation with spacer plates and spacer brackets in the case of external insulation
210 x 230 x 2 mm 230 x 210 x 2 mm
(please refer to the section "Technical Information")
(please refer to the section "Technical Information")
(please refer to the section "Technical Information")
77968. 71843. 71844.
Fixtures, fittings and accessories
. = Please insert the RAL No. (please refer to the section on "Coatings")
205Fitting
Accessories
Technical Information
Optional Accessories
markilux75
markilux790
markilux1300 stretch
markilux1300
markilux1100
markilux1000 stretch
markilux1000
markilux930 swing
markilux1650
markilux1600 pavilion 2
markilux1600 stretch
markilux1600
markilux1550
markilux1500
markilux 1200 stretch
markilux1200
markilux990
markilux3300 /
3300 pur
markilux5010
markilux6000
markiluxES-1
Specification
markilux Collection
General Information
markilux 1600
Bolt reduction assembly M 16 - M 12 / SW 27
Bolt reduction assembly M 16 - M 10 / SW 27
Bolt reduction assembly M 12 - M 10 / SW 27
50 mm length 50 mm length 50 mm length
(please refer to the section "Technical Information")
(please refer to the section "Technical Information")
(please refer to the section "Technical Information")
753891 754921 754911Bolt reduction assembly M 10 - M 10 / SW 27
Wall sealing profile Stand-off strip for wall sealing profile
50 mm length available by the metre available by the metre
(please refer to the section "Technical Information")
fixture example: see face fixture with wall sealing profile
fixture example: see face fixture with wall sealing profile754901 77780. 751971
Angled profile for eaves fixture,
100 x 100 mm
available by the metre, undrilled
793800 machine finish79380.
206
Pull-out force [N=Newton] per upper fixture point according to EN 13561, wind resistance class 2
dimensions in mm
markilux 1600
17,5
100
65 17,5
45
71813. 70867.
158
17
16
22,5
92 76
1414
14 14
223
250
243
5°
50°
152
253
254
75
WA120
158
65 1990
49
27
The pull-out force refers to the vertical centre to centre measurement between the fixture points of 90 mm. If this measurement is reduced, the pull-out force increases by 14% in the case of compression-proof substrates and by 19% in the case of non-compression-proof substrates. If the awning is fixed with 2 brackets per folding arm, the extension force can be halved.
M = overall awning widthH = projectionFB = pull-out force per fixing pointHT | BHT = bracket quantity | widthBM = no. of fixing pointsWA = wall sealing profile71813. = face fixture bracket assembly 45 mm 70867. = face fixture bracket assembly 100 mm
��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ���������
��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ���� ���� ���� ���� ���
��� ��� ��� ��� ���� ���� ���� ���� ���� ���� ���� ��� ���� ���� ���� ���� ���� ���� ���� ���� ����
��� ��� ���� ���� ���� ���� ���� ���� ���� ���� ���� ��� ���� ���� ���� ���� ���� ���� ���� ���� ����
��� ��� ��� ���� ���� ���� ���� ���� ���� ���� ���� ��� ��� ���� ���� ���� ���� ���� ���� ���� ����
��� ��� ��� ��� ���� ���� ���� ���� ���� ���� ���� ��� ��� ��� ���� ���� ���� ���� ���� ���� ����
��� ��� ��� ��� ��� ���� ���� ���� ���� ��� ���� ��� ��� ��� ��� ���� ���� ���� ���� ��� ����
�
��������������������
���
������������
���
����
�����
��
����������
������������
�
����������
������������
�
�����
��
����������
����������
�
����������
������������
�
����
compression-proof substrate non compression-proof substrate
Face fixture
207
Pull-out force [N=Newton] per upper fixture point according to EN 13561, wind resistance class 2
dimensions in mm
Fitting Accessories
Technical Information
Optional Accessories
markilux75
markilux790
markilux1300 stretch
markilux1300
markilux1100
markilux1000 stretch
markilux1000
markilux930 swing
markilux1650
markilux1600 pavilion 2
markilux1600 stretch
markilux1600
markilux1550
markilux1500
markilux 1200 stretch
markilux1200
markilux990
markilux3300 /
3300 pur
markilux5010
markilux6000
markiluxES-1
Specification
markilux Collection
General Information
markilux 1600
223
243
50°
5°
266
120 WA75197.
75
137
164
30 70 230 30
430
70
4276
42
160
18 12
265
6
The pull-out force refers to the vertical centre to centre measurement between the fixing points of 76 mm. In the case of spreader plates a washer conforming to DIN 9021 must be used.
M = overall awning widthH = projectionFB = pull-out force per fixing pointHT | BHT = bracket quantity | widthBP = no. of spreader platesDP = no. of spacer platesBM = no. of fixing pointsWA = wall sealing profile75197. = stand-off strip for wall sealing profile
compression-proof substrate non compression-proof substrate
Face fixture with spreader plate A
208
Pull-out force [N=Newton] per upper fixture point according to EN 13561, wind resistance class 2
dimensions in mm
markilux 1600
266
223
300
25 250 25 12
243
50°
5°
2525
400
350
146
18
158
96
265
The pull-out force refers to the vertical centre to centre measurement between the fixing points of 350 mm. In the case of spreader plates a washer conforming to DIN 9021 must be used.
M = overall awning widthH = projectionFB = pull-out force per fixing pointHT | BHT = bracket quantity | widthBP = no. of spreader platesDP = no. of spacer platesBM = no. of fixing points
compression-proof substrate non compression-proof substrate
Face fixture with spreader plate B
209
Pull-out force [N=Newton] per upper fixture point according to EN 13561, wind resistance class 2
dimensions in mm
Fitting Accessories
Technical Information
Optional Accessories
markilux75
markilux790
markilux1300 stretch
markilux1300
markilux1100
markilux1000 stretch
markilux1000
markilux930 swing
markilux1650
markilux1600 pavilion 2
markilux1600 stretch
markilux1600
markilux1550
markilux1500
markilux 1200 stretch
markilux1200
markilux990
markilux3300 /
3300 pur
markilux5010
markilux6000
markiluxES-1
Specification
markilux Collection
General Information
markilux 1600
170120
170
120
18
A
A
77968.77967.
190140
18
A
A
max. 300min. 8010A-A
62,50
The pull-out force refers to the vertical centre to centre measurement between the fixing points of 120 mm. In the case of spacer plates a washer conforming to DIN 9021 must be used.
M = overall awning widthH = projectionFB = pull-out force per fixing pointHT | BHT = bracket quantity | widthBM = no. of fixing pointsDH = no. of spacer brackets77967. = spacer bracket for face fixture bracket 71813.77968. = spacer bracket for face fixture bracket 70867.
compression-proof substrate non compression-proof substrate
Face fixture with stand-off brackets
210
Pull-out force [N=Newton] per upper fixture point according to EN 13561, wind resistance class 2
dimensions in mm
markilux 1600
223
251
5°
50°
75
284
WA120
143
158
1990
49
269
17,5
100
65 17,5
45
17
22,5
71813. 70867.
158
16
92 76
1414
14 14
The pull-out force refers to the vertical centre to centre measurement between the fixture points of 90 mm. If this measurement is reduced, the pull-out force increases by 14% in the case of compression-proof substrates and by 19% in the case of non-compression-proof substrates. If the awning is fixed with 2 brackets per folding arm, the extension force can be halved.
M = overall awning widthH = projectionFB = pull-out force per fixing pointHT | BHT = bracket quantity | widthBM = no. of fixing pointsWA = wall sealing profile71813. = face fixture bracket assembly 45 mm 70867. = face fixture bracket assembly 100 mm
compression-proof substrate non compression-proof substrate
Face fixture with shadeplus
211
Pull-out force [N=Newton] per upper fixture point according to EN 13561, wind resistance class 2
dimensions in mm
Fitting Accessories
Technical Information
Optional Accessories
markilux75
markilux790
markilux1300 stretch
markilux1300
markilux1100
markilux1000 stretch
markilux1000
markilux930 swing
markilux1650
markilux1600 pavilion 2
markilux1600 stretch
markilux1600
markilux1550
markilux1500
markilux 1200 stretch
markilux1200
markilux990
markilux3300 /
3300 pur
markilux5010
markilux6000
markiluxES-1
Specification
markilux Collection
General Information
markilux 1600
137
7030 230 70 30
430
75197.
42
160
7642
223
120
75
296
6
164
18
12281
251
WA
50°
5°
The pull-out force refers to the vertical centre to centre measurement between the fixing points of 76 mm. In the case of spreader plates a washer conforming to DIN 9021 must be used.
M = overall awning widthH = projectionFB = pull-out force per fixing pointHT | BHT = bracket quantity | widthBP = no. of spreader platesDP = no. of spacer platesBM = no. of fixing pointsWA = wall sealing profile75197. = stand-off strip for wall sealing profile
compression-proof substrate non compression-proof substrate
Face fixture with shadeplus and spreader plate A
212
Pull-out force [N=Newton] per upper fixture point according to EN 13561, wind resistance class 2
dimensions in mm
markilux 1600
296
25 25250
300
12
223
251
50°
5°
18 281
146
9615
8
25
400
350
25
The pull-out force refers to the vertical centre to centre measurement between the fixing points of 350 mm. In the case of spreader plates a washer conforming to DIN 9021 must be used.
M = overall awning widthH = projectionFB = pull-out force per fixing pointHT | BHT = bracket quantity | widthBP = no. of spreader platesDP = no. of spacer platesBM = no. of fixing points
compression-proof substrate non compression-proof substrate
Face fixture with shadeplus and spreader plate B
213
Pull-out force [N=Newton] per upper fixture point according to EN 13561, wind resistance class 2
dimensions in mm
Fitting Accessories
Technical Information
Optional Accessories
markilux75
markilux790
markilux1300 stretch
markilux1300
markilux1100
markilux1000 stretch
markilux1000
markilux930 swing
markilux1650
markilux1600 pavilion 2
markilux1600 stretch
markilux1600
markilux1550
markilux1500
markilux 1200 stretch
markilux1200
markilux990
markilux3300 /
3300 pur
markilux5010
markilux6000
markiluxES-1
Specification
markilux Collection
General Information
markilux 1600
170120
170
120
18
A
A
77968.77967.
190140
18
A
A
max. 300min. 8010A-A
62,50
The pull-out force refers to the vertical centre to centre measurement between the fixing points of 120 mm. In the case of spacer plates a washer conforming to DIN 9021 must be used.
M = overall awning widthH = projectionFB = pull-out force per fixing pointHT | BHT = bracket quantity | widthBM = no. of fixing pointsDH = no. of spacer brackets77967. = spacer bracket for face fixture bracket 71813.77968. = spacer bracket for face fixture bracket 70867.
compression-proof substrate non compression-proof substrate
Face fixture for Shadeplus / drop valance with stand-off brackets
214
Pull-out force [N=Newton] per upper fixture point according to EN 13561, wind resistance class 2
dimensions in mm
markilux 1600
223
243
5°
50°
256
14
90
17,5
5517
,5
335
260
140
45 80 15
259
14
140
45 80 15
71818.70868.
45
22,5
1414
The pull-out force refers to the horizontal centre to centre measurement between the fixing points of 80 mm. If the awning is fitted with two brackets per folding arm the pull-out force may be halved. Position the brackets to the left and right of the arm bearer. Place the brackets to the left and right of the arm bearer. M = overall awning widthH = projectionFB = pull-out force per fixing pointHT | BHT = bracket quantity | widthBM = no. of fixing points70868. = top fixture bracket assembly 90 mm 71818. = top fixture bracket assembly 45 mm
compression-proof substrate non compression-proof substrate
Top fixture
215
Pull-out force [N=Newton] per upper fixture point according to EN 13561, wind resistance class 2
dimensions in mm
Fitting Accessories
Technical Information
Optional Accessories
markilux75
markilux790
markilux1300 stretch
markilux1300
markilux1100
markilux1000 stretch
markilux1000
markilux930 swing
markilux1650
markilux1600 pavilion 2
markilux1600 stretch
markilux1600
markilux1550
markilux1500
markilux 1200 stretch
markilux1200
markilux990
markilux3300 /
3300 pur
markilux5010
markilux6000
markiluxES-1
Specification
markilux Collection
General Information
markilux 1600
223
251
50°
5°
290
275
256
90
17,5
5517
,5
343
140
45 80 15
14
14
45
140
45 80 1522,5
70868. 71818.14
14
The pull-out force refers to the horizontal centre to centre measurement between the fixing points of 80 mm. If the awning is fitted with two brackets per folding arm the pull-out force may be halved. Position the brackets to the left and right of the arm bearer. Place the brackets to the left and right of the arm bearer. M = overall awning widthH = projectionFB = pull-out force per fixing pointHT | BHT = bracket quantity | widthBM = no. of fixing points70868. = top fixture bracket assembly 90 mm 71818. = top fixture bracket assembly 45 mm
compression-proof substrate non compression-proof substrate
Top fixture with shadeplus
216
dimensions in mm
markilux 1600
Torque [Nm = Newton metres] for the fixture bracket next to the arm, shear force [N = Newton] per fixing point according to EN 13561, wind resistance class 2
260
223
90
120
259
243
5°
50°
256
150 30°
50
335
The shear force is calculated on the basis of 2 fixing points per bracket, because - depending on the roof pitch - it cannot be guaranteed that 4 fixing points per bracket can used.
M = overall awning widthH = projectionMd = torque value for the bracket in the immediate vicinity of the armHT = bracketFS = shear forceBM = no. of fixing points
Torque Shear force
Eaves fixture
217
dimensions in mm
Fitting Accessories
Technical Information
Optional Accessories
markilux75
markilux790
markilux1300 stretch
markilux1300
markilux1100
markilux1000 stretch
markilux1000
markilux930 swing
markilux1650
markilux1600 pavilion 2
markilux1600 stretch
markilux1600
markilux1550
markilux1500
markilux 1200 stretch
markilux1200
markilux990
markilux3300 /
3300 pur
markilux5010
markilux6000
markiluxES-1
Specification
markilux Collection
General Information
markilux 1600
Torque [Nm = Newton metres] for the fixture bracket next to the arm, shear force [N = Newton] per fixing point according to EN 13561, wind resistance class 2
120
200
260
260
22325
6
150
30°
90
259
243
335
5°
50°
By using the additional flat fixture plate, the shear force is reduced in comparison with conventional eaves fixture.
M = overall awning widthH = projectionMd = torque value for the bracket in the immediate vicinity of the armHT = bracketFS = shear forceBM = no. of fixing points
Torque Shear force
Eaves fixture with additional plate
218
dimensions in mm
dimensions in mm
markilux 1600
39
Cable exit position on motor-driven units
17,5
100
65 17,5
14
17
167692
158
65 1990
49
27
223
250
243
5°
50°
152
253
254
75
WA120
14
Face fixture with manual operation
WA = wall sealing profile
219
dimensions in mm
Fitting Accessories
Technical Information
Optional Accessories
markilux75
markilux790
markilux1300 stretch
markilux1300
markilux1100
markilux1000 stretch
markilux1000
markilux930 swing
markilux1650
markilux1600 pavilion 2
markilux1600 stretch
markilux1600
markilux1550
markilux1500
markilux 1200 stretch
markilux1200
markilux990
markilux3300 /
3300 pur
markilux5010
markilux6000
markiluxES-1
Specification
markilux Collection
General Information
markilux 1600
100
14
143
17,5 65 17,5
92 7616
17
158
4990
19
75
120
254
223
220
243
258
253
WA
50°
5°
15°14
Dimensions at different awning pitches
WA = wall sealing profile
220
dimensions in cm
markilux 1600
▲ = please note the minimum widths, dimension A is only valid for standard arms! (Dimension A is 13 cm smaller in the case of bespoke arms.) In the case of small awnings the brackets can only be fitted inside the arms, i.e. the position denoted by measurement A.
■ = coupled units are only available with junction roller in the standard widths, in the case of other widths please ask us.
M = overall awning widthH = projectionA = arm positionHT = bracketHT | BHT = bracket quantity | widthMB = bracket fixture rangeW = face fixtureDE/DA = top fixture and eaves fixtureSB = standard widthZB = intermediate widthLR = rolltex bearing with bracket is always placed under a central seam (depends on the awning size)
If the brackets cannot be positioned in accordance with this table, make sure the actual measurements are noted on the order form!
dimensions in cm
Bracket range for awnings with 2 folding arms
221
dimensions in cm
Fitting Accessories
Technical Information
Optional Accessories
markilux75
markilux790
markilux1300 stretch
markilux1300
markilux1100
markilux1000 stretch
markilux1000
markilux930 swing
markilux1650
markilux1600 pavilion 2
markilux1600 stretch
markilux1600
markilux1550
markilux1500
markilux 1200 stretch
markilux1200
markilux990
markilux3300 /
3300 pur
markilux5010
markilux6000
markiluxES-1
Specification
markilux Collection
General Information
markilux 1600
▲ = please note the minimum widths, dimension A is only valid for standard arms! coupled units are not available with junction roller.
M = overall awning widthH = projectionA = arm positionB = arm positionHT = bracketHT | BHT = bracket quantity | widthMB = bracket fixture rangeW = face fixtureDE/DA = top fixture and eaves fixtureSB = standard widthZB = intermediate widthLR = rolltex bearing with bracket is always placed under a central seam (depends on the awning size)
If the brackets cannot be positioned in accordance with this table, make sure the actual measurements are noted on the order form!
dimensions in cm
20 15 20 2015 62014 20206 6
B
118 118
A
M
9 9A
=MBLR LR HT
Bracket range for awnings with 3 folding arms
222