84
C 2016 Honda Motor Co., Ltd. -All Rights Reserved See page 74 for Initial Use Instructions GENERATOR EB3000c Owner’s Manual

GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

C 2016 Honda Motor Co., Ltd. -All Rights Reserved

See page 74 for Initial Use Instructions

GENERATOR

BK PANTONE186C

EB3000c

31Z0372300X31-Z03-7230 Printed in Japan

FM

HiEM4 英AH

Owner’s Manual

Page 2: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 0 ページ 2016年9月8日 木曜日 午後8時45分

California Proposition 65

This product contains or emits

chemicals known to the state of

California to cause cancer, birth defects

or other reproductive harm

Keep this owner’s manual handy, so that you can refer to it any time.

This owner’s manual is considered a permanent part of the generator

and should remain with the generator if resold.

The information and specifications included in this publication were in

effect at the time of approval for printing. Honda Motor Co., Ltd.

reserves the right, however, to discontinue or change specifications or

design at any time without notice and without incurring any obligation

whatsoever.

The engine exhaust from this

product contains chemicals known

to the State of California to cause

cancer, birth defects or other

reproductive harm.

Exhaust contains poisonous carbon

monoxide gas that can build up to

dangerous levels in closed areas.

Breathing carbon monoxide can

cause unconsciousness or death.

Never run the generator in a closed,

or even partly closed area where

people may be present.

Page 3: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 1 ページ 2016年9月8日 木曜日 午後8時45分

INTRODUCTION

Congratulations on your selection of a Honda generator. We are certain

you will be pleased with your purchase of one of the finest generators

on the market.

We want to help you get the best results from your new generator and

to operate it safely. This manual contains the information on how to

do that; please read it carefully.

As you read this manual, you will find information preceded by a

symbol. That information is intended to help you avoid damage

to your generator, other property, or the environment.

We suggest you read the Distributor’s Limited Warranty (see page 64)

to fully understand its coverage and your responsibilities of

ownership.

When your generator needs scheduled maintenance, keep in mind that

your Honda servicing dealer is specially trained in servicing Honda

generators and is supported by the parts and service divisions of

American Honda. Your Honda servicing dealer is dedicated to your

satisfaction and will be pleased to answer your questions and concerns.

Best Wishes, Honda Motor Co., Ltd.

1

Page 4: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 2 ページ 2016年9月8日 木曜日 午後8時45分

A FEW WORDS ABOUT SAFETY

Your safety and the safety of others are very important. And using this

generator safely is an important responsibility.

To help you make informed decisions about safety, we have provided

operating procedures and other information on labels and in this

manual. This information alerts you to potential hazards that could

hurt you or others.

Of course, it is not practical or possible to warn you about all the

hazards associated with operating or maintaining a generator. You

must use your own good judgment.

You will find important safety information in a variety of forms,

including:

• Safety Labels — on the generator.

• Safety Messages — preceded by a safety alert symbol and one

of three signal words, DANGER, WARNING, or CAUTION.

These signal words mean:

• Safety Headings — such as IMPORTANT SAFETY INFORMATION.

• Safety Section — such as GENERATOR SAFETY.

• Instructions — how to use this generator correctly and safely.

This entire book is filled with important safety information — please

read it carefully.

You WILL be KILLED or SERIOUSLY HURT if

you don’t follow instructions.

You CAN be KILLED or SERIOUSLY HURT if

you don’t follow instructions.

You CAN be HURT if you don’t follow

instructions.

2

Page 5: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 3 ページ 2016年9月8日 木曜日 午後8時45分

CONTENTS

GENERATOR SAFETY ...............................................................................6

IMPORTANT SAFETY INFORMATION .................................................6

Operator Responsibility.....................................................................6

Carbon Monoxide Hazards................................................................6

Electric Shock Hazards ......................................................................7

Fire and Burn Hazards .......................................................................7

Refuel With Care ................................................................................7

SAFETY LABEL LOCATIONS.................................................................8

CONTROLS & FEATURES.........................................................................9

COMPONENT & CONTROL LOCATIONS.............................................9

CONTROLS...........................................................................................11

Fuel Valve Lever...............................................................................11

Engine Switch ..................................................................................11

Choke Rod ........................................................................................11

Recoil Starter....................................................................................12

AC Circuit Protector .........................................................................12

AC Circuit Breaker............................................................................13

Ground Fault Circuit Interrupter (GFCI)..........................................14

FEATURES............................................................................................15

Ground Terminal..............................................................................15

Output Indicator ...............................................................................16

Oil Alert Indicator.............................................................................17

Fuel Gauge .......................................................................................18

BEFORE OPERATION ..............................................................................19

ARE YOU READY TO GET STARTED?................................................19

Knowledge........................................................................................19

IS YOUR GENERATOR READY TO GO?.............................................19

Check the Engine .............................................................................20

Check the GFCI .................................................................................20

3

Page 6: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 4 ページ 2016年9月8日 木曜日 午後8時45分

CONTENTS

OPERATION .............................................................................................21

SAFE OPERATING PRECAUTIONS.....................................................21

STARTING THE ENGINE .....................................................................22

STOPPING THE ENGINE .....................................................................24

GFCI OPERATION CHECK ...................................................................25

AC OPERATION....................................................................................27

AC Applications................................................................................29

STANDBY POWER...............................................................................30

Connections to a Building’s Electrical System ..............................30

System Ground ................................................................................30

Special Requirements......................................................................30

SERVICING YOUR GENERATOR............................................................31

THE IMPORTANCE OF MAINTENANCE.............................................31

MAINTENANCE SAFETY.....................................................................32

Safety Precautions ...........................................................................32

MAINTENANCE SCHEDULE ...............................................................33

REFUELING ..........................................................................................34

FUEL RECOMMENDATIONS...............................................................35

ENGINE OIL LEVEL CHECK .................................................................36

ENGINE OIL CHANGE..........................................................................37

ENGINE OIL RECOMMENDATIONS...................................................38

AIR CLEANER SERVICE.......................................................................39

FOAM AIR FILTER CLEANING ............................................................40

SEDIMENT CUP CLEANING................................................................41

SPARK PLUG SERVICE........................................................................43

SPARK ARRESTER SERVICE...............................................................45

STORAGE.................................................................................................46

STORAGE PREPARATION...................................................................46

Cleaning............................................................................................46

Fuel....................................................................................................46

Engine Oil .........................................................................................49

Engine Cylinder................................................................................49

STORAGE PRECAUTIONS ..................................................................50

REMOVAL FROM STORAGE...............................................................50

4

Page 7: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 5 ページ 2016年9月8日 木曜日 午後8時45分

CONTENTS

TRANSPORTING......................................................................................51

TAKING CARE OF UNEXPECTED PROBLEMS ......................................52

ENGINE WILL NOT START..................................................................52

ENGINE LACKS POWER......................................................................52

NO POWER AT THE AC RECEPTACLES.............................................53

TECHNICAL INFORMATION ...................................................................54

Serial Number Location ..................................................................54

Carburetor Modification for High Altitude Operation...................55

Emission Control System Information...........................................56

Air Index ...........................................................................................59

Specifications ...................................................................................60

Wiring Diagram................................................................................61

CONSUMER INFORMATION ..................................................................62

Dealer Locator Information .............................................................62

Honda Publications..........................................................................62

Customer Service Information........................................................63

Distributor’s Limited Warranty .......................................................64

Emission Control System Warranty ...............................................69

INITIAL USE INSTRUCTIONS .................................................................74

ENGINE OIL..........................................................................................74

FUEL......................................................................................................75

BEFORE OPERATION...........................................................................76

REGISTRATION....................................................................................76

INDEX .......................................................................................................77

QUICK REFERENCE INFORMATION ............................ Inside back cover

5

Page 8: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 6 ページ 2016年9月8日 木曜日 午後8時45分

GENERATOR SAFETY

IMPORTANT SAFETY INFORMATION

Honda generators are designed for use with electrical equipment that

has suitable power requirements. Other uses can result in injury to the

operator or damage to the generator and other property. Most injuries or property damage can be prevented if you follow all

the instructions in this manual and on the generator. The most

common hazards are discussed below, along with the best way to

protect yourself and others.

Never attempt to modify the generator. It could result in an injury as

well as damage to the generator and/or the attached appliances.

• Do not connect an extension to the muffler.

• Do not modify the intake system.

• Do not remove the control panel or change the control panel wiring.

Operator Responsibility

• Know how to stop the generator quickly in case of emergency.

• Understand the use of all generator controls, output receptacles, and

connections.

• Be sure that anyone who operates the generator receives proper

instruction. Do not let children operate the generator without parental

supervision.

Carbon Monoxide Hazards

A generator's exhaust contains toxic carbon monoxide, which you

cannot see or smell. Breathing carbon monoxide can KILL YOU IN

MINUTES. To avoid carbon monoxide poisoning, follow these

instructions when operating a generator:

• Only run a generator OUTSIDE, far away from windows, doors, and

vents.

• Never operate a generator inside a house, garage, basement, crawl

space, or any enclosed or partially enclosed space.

• Never operate a generator near open doors or windows.

• Get fresh air and seek medical attention immediately if you suspect

you have inhaled carbon monoxide.

Early symptoms of carbon monoxide exposure include headache,

fatigue, shortness of breath, nausea, and dizziness. Continued

exposure to carbon monoxide can cause loss of muscular coordination,

loss of consciousness, and then death.

6

Page 9: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 7 ページ 2016年9月8日 木曜日 午後8時45分

GENERATOR SAFETY

To alert you to potentially dangerous levels of carbon monoxide coming

from a generator operating outside or from other sources, install

battery operated carbon monoxide alarms or plug-in carbon monoxide

alarms with battery back-up on every level of the home and outside

sleeping areas, according to the manufacturer’s instructions.

Electric Shock Hazards

• The generator produces enough electric power to cause a serious

shock or electrocution if misused.

• Using a generator or electrical appliance in wet conditions, such as

rain or snow, or near a pool or sprinkler system, or when your

hands are wet, could result in electrocution. Keep the generator dry.

• If the generator is stored outdoors, unprotected from the weather,

check the Ground Fault Circuit Interrupter (GFCI) receptacle and all

other electrical components on the control panel before each use.

Moisture or ice can cause a malfunction or short circuit in electrical

components that could result in electrocution.

Fire and Burn Hazards

• The exhaust system gets hot enough to ignite some materials.

– Keep the generator at least 3 feet (1 meter) away from buildings

and other equipment during operation.

– Do not enclose the generator in any structure.

– Keep flammable materials away from the generator.

• The muffler becomes very hot during operation and remains hot for

a while after stopping the engine. Be careful not to touch the muffler

while it is hot. Let the engine cool before storing the generator

indoors.

Refuel With Care

• Gasoline is extremely flammable, and gasoline vapor can explode.

• Do not refuel during operation.

• Allow the engine to cool if it has been in operation.

• Refuel only outdoors in a well-ventilated area and on a level surface.

• Never smoke near gasoline, and keep other flames and sparks away.

• Do not overfill the fuel tank. Overfilling the fuel tank may cause fuel

to leak out of the bottom of the EVAP canister.

• Make sure that any spilled fuel has been wiped up and cleaned

before starting the engine.

• Always store gasoline in an approved container.

7

Page 10: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 8 ページ 2016年9月8日 木曜日 午後8時45分

GENERATOR SAFETY

SAFETY LABEL LOCATIONS

These labels warn you of potential hazards that can cause serious

injury. Read them carefully. If a label comes off or becomes hard to

read, contact your Honda servicing dealer for a replacement.

8

Page 11: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 9 ページ 2016年9月8日 木曜日 午後8時45分

CONTROLS & FEATURES

COMPONENT & CONTROL LOCATIONS

Use the two illustrations on these pages to locate and identify the

most frequently used controls.

AC RECEPTACLES

GFCI TEST BUTTON

LEDOIL ALERT INDICATOR

OUTPUT INDICATOR

ENGINE SWITCH

AC CIRCUIT BREAKER

AC CIRCUIT PROTECTOR

GROUND TERMINAL

CONTROL PANEL

9

Page 12: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 10 ページ 2016年9月8日 木曜日 午後8時45分

CONTROL & FEATURES

FUEL VALVE LEVER

AIR CLEANER

FUEL SEDIMENT CUP

STARTER GRIP

CYCLOCONVERTER UNIT

OIL FILLER CAP

CONTROL PANEL

FUEL GAUGEFUEL TANK CAP

MUFFLER

CHOKE ROD

SPARK PLUG CAP

EVAP CANISTEROIL DRAIN PLUG

10

Page 13: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 11 ページ 2016年9月8日 木曜日 午後8時45分

CONTROL & FEATURES

CONTROLS

Fuel Valve Lever

The fuel valve lever is located

between the fuel tank and

carburetor.

The fuel valve lever must be in the

ON position for the engine to run.

After stopping the engine, turn

the fuel valve lever to the OFF

position.

Engine Switch

The engine switch controls the

ignition system.

OFF – Stops the engine.

ON – Running position, and for

starting with the recoil starter.

Choke Rod

The choke rod opens and closes

the choke valve in the carburetor.

Pulling the choke rod to the

CLOSED position enriches the fuel

mixture for starting a cold engine.

Pushing the choke rod to the

OPEN position provides the

correct fuel mixture for operation

after starting, and for restarting a

warm engine.

FUEL VALVE LEVER

ON

ENGINE SWITCH

OFF

ONOFF

OPEN

CLOSED

CHOKE ROD

11

Page 14: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 12 ページ 2016年9月8日 木曜日 午後8時45分

CONTROL & FEATURES

Recoil Starter

Pulling the starter grip operates

the recoil starter to crank the

engine for starting.

• Do not allow the starter grip to

snap back against the engine.

Return it gently to prevent

damage to the starter.

• Do not let the starter rope rub

against the generator body, or

the rope will wear out

prematurely.

AC Circuit Protector

The AC circuit protector will automatically switch to OFF if there is a short circuit or a significant overload of the generator at each receptacle. If an AC circuit protector switches OFF automatically, check that the appliance is working properly and does not exceed the rated load capacity of the circuit before resetting the AC circuit protector ON.

STARTER GRIP

Direction to pull

20 A RECEPTACLES

30 A RECEPTACLE

ON

OFF

PUSHAC CIRCUIT PROTECTOR

12

Page 15: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 13 ページ 2016年9月8日 木曜日 午後8時45分

CONTROL & FEATURES

AC Circuit Breaker

The AC circuit breaker will automatically switch OFF if there is a short

circuit or a significant overload at the receptacles, or if the ground

fault circuit interrupter (GFCI) detects a ground fault current.

The AC circuit breaker may be used to switch the generator power ON

or OFF.

ON

OFF

AC CIRCUIT BREAKER

13

Page 16: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 14 ページ 2016年9月8日 木曜日 午後8時45分

CONTROL & FEATURES

Ground Fault Circuit Interrupter (GFCI)

All receptacles on the generator are protected by a Ground Fault Circuit Interrupter (GFCI) for protection against the shock hazard of ground fault current.

An example of ground-fault current is the current that would flow through a person who is using an appliance with faulty insulation and, at the same time, is in contact with an electrical ground such as a plumbing fixture, wet floor, or earth. The GFCI will protect against current flowing through that person.

The GFCI will not protect against short circuits or overloads. The AC circuit breaker and AC circuit protector provide that protection (see pages 12 and 13).

GFCIs can be expected to interrupt power supply if there are ground faults or stray current imposed on the wiring by other electrical devices, wiring, or equipment. Due to the risk of a power interruption, this generator is not recommended for powering medical or life support equipment.

AC CIRCUIT BREAKER

GFCI TEST BUTTON

14

Page 17: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 15 ページ 2016年9月8日 木曜日 午後8時45分

CONTROL & FEATURES

FEATURES

Ground Terminal

The ground terminal is connected to the frame of the generator, the

metal non-current-carrying parts of the generator, and the ground

terminals of each receptacle.

Before using the ground terminal, consult a qualified electrician,

electrical inspector, or local agency having jurisdiction for local codes

or ordinances that apply to the intended use of the generator.

NEUTRAL BONDED TO FRAME:

There is a permanent conductor between the generator (stator

winding) and the frame.

GROUND TERMINAL

15

Page 18: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 16 ページ 2016年9月8日 木曜日 午後8時45分

CONTROL & FEATURES

Output Indicator

The output indicator (green) will remain ON during normal operating

conditions.

If there is a short circuit in a connected appliance or if the

CycloConverterTM unit overheats, the output indicator (green) blinks

and current to the connected appliance(s) will shut off. When this

happens, disconnect the appliance(s) and stop the engine to

investigate the problem.

Determine if the cause is a short circuit in a connected appliance or an

overheated CycloConverter unit. Correct the problem and restart the

engine.

If the output indicator (green) blinks again, consult your Honda

generator dealer.

The output indicator (green) may blink at intervals of 2.5 seconds,

depending on connected appliance(s) to the AC receptacles. It

indicates that the output voltage has dropped slightly. It does not

matter as long as the connected appliance(s) work properly.

OUTPUT INDICATOR (GREEN)

16

Page 19: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 17 ページ 2016年9月8日 木曜日 午後8時45分

CONTROL & FEATURES

Oil Alert® Indicator

The Oil Alert® system is designed to prevent engine damage caused

by an insufficient amount of oil in the crankcase. Before the oil level in

the crankcase can fall below a safe limit, the Oil Alert indicator comes

on, and the Oil Alert system automatically will stop the engine (the

engine switch will remain in the ON position).

If the engine stops or the Oil Alert indicator comes on when you pull the starter grip, check the engine oil level (see page 36) before troubleshooting in other areas.

OIL ALERT INDICATOR (RED)

17

Page 20: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 18 ページ 2016年9月8日 木曜日 午後8時45分

CONTROL & FEATURES

Fuel Gauge

The fuel gauge is a mechanical device that measures the fuel level in

the tank. The red indicator in the window will reference the level in

relation to full or empty. To provide increased operating time, start

with a full tank before beginning operation. Check the fuel level with

the generator on a level surface. Always refuel with the engine OFF

and cool.

FUEL TANK CAP

TETHER

FUEL LEVEL GAUGE

FULL EMPTY

18

Page 21: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 19 ページ 2016年9月8日 木曜日 午後8時45分

BEFORE OPERATION

ARE YOU READY TO GET STARTED?

Your safety is your responsibility. A little time spent in preparation will significantly reduce your risk of injury.

Knowledge

Read and understand this manual. Know what the controls do and how to operate them.

Familiarize yourself with the generator and its operation before you begin using it. Know how to quickly shut off the generator in case of an emergency.

If the generator is being used to power appliances, be sure that they do not exceed the generator’s load rating (see page 29).

IS YOUR GENERATOR READY TO GO?

For your safety, to ensure compliance with environmental regulations, and to maximize the service life of your equipment, it is very important to take a few moments before you operate the generator to check its condition. Be sure to take care of any problem you find, or have your servicing dealer correct it, before you operate the generator.

To prevent a possible fire, keep the generator at least 3 feet (1 meter) away from building walls and other equipment during operation. Do not place flammable objects close to the engine.

Before beginning your pre-operation checks, be sure the generator is on a level surface and the engine switch is in the OFF position.

Failure to properly maintain this

generator, or failing to correct a

problem before operation, could

result in a significant malfunction.

Some malfunctions can seriously

hurt or kill you.

Always perform a pre-operation

inspection before each operation

and correct any problems.

19

Page 22: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 20 ページ 2016年9月8日 木曜日 午後8時45分

BEFORE OPERATION

Check the Engine

• Before each use, look around and underneath the engine for signs of

oil or gasoline leaks.

• Check the oil level (see page 36). A low oil level will cause the Oil

Alert system to shut down the engine.

• Check the air filter (see page 39). A dirty air filter will restrict air flow

to the carburetor, reducing engine and generator performance.

• Check the fuel level (see page 34). Starting with a full tank will help

to eliminate or reduce operating interruptions for refueling.

Check the GFCI

Check the GFCI operation (see page 25) after starting the engine.

20

Page 23: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 21 ページ 2016年9月8日 木曜日 午後8時45分

OPERATION

SAFE OPERATING PRECAUTIONS

Before operating the generator for the first time, review chapters GENERATOR SAFETY (see page 6) and BEFORE OPERATION (see page 19).

For your safety, do not operate the generator in an enclosed area such as a garage. Your generator’s exhaust contains poisonous carbon monoxide gas that can collect rapidly in an enclosed area and cause illness or death.

Before connecting an AC appliance or power cord to the generator:

• Use grounded 3-prong extension cords, tools, and appliances, or

double-insulated tools and appliances.

• Inspect cords and plugs, and replace if damaged.

• Do not use cord lengths greater than 164 feet (50 meters), and do

not use multiple tools and appliances with built-in noise filters. Such

use may activate the GFCI and trip the circuit breaker.

• Make sure that the appliance is in good working order. Faulty

appliances or power cords can create a potential for electric shock.

• Make sure the electrical rating of the tool or appliance does not

exceed the rated power of the generator or the receptacle being

used.

• Operate the generator at least 3 feet (1 meter) away from buildings

and other equipment.

• Do not operate the generator in an enclosed structure.

• Do not place flammable objects close to the engine or locate the

generator near flammable materials.

Exhaust contains poisonous carbon

monoxide gas that can build up to

dangerous levels in closed areas.

Breathing carbon monoxide can cause

unconsciousness or death.

Never run this product's engine in a

closed, or even partly closed area.

21

Page 24: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 22 ページ 2016年9月8日 木曜日 午後8時45分

OPERATION

STARTING THE ENGINE

Refer to SAFE OPERATING PRECAUTIONS on page 21.

1. Make sure that all appliances

are disconnected from the AC

receptacle.

2. Make sure that the AC circuit

breaker is in the OFF position.

3. Turn the fuel valve lever to the

ON position.

4. Pull the choke rod to the

CLOSED position to start a cold

engine. Leave the choke rod in the

OPEN position to start a warm

engine.

AC CIRCUIT BREAKER

OFF

ON

OFF

FUEL VALVE LEVER

CHOKE ROD

OPEN

CLOSED

22

Page 25: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 23 ページ 2016年9月8日 木曜日 午後8時45分

OPERATION

5. Turn the engine switch to the

ON position.

6. Pull the starter grip lightly until

resistance is felt, then pull

briskly.

• Do not allow the starter grip

to snap back against the

engine. Return it gently to

prevent damage to the

starter.

• Do not let the starter rope rub

against the generator body,

or the rope will wear out

prematurely.

7. If the choke rod was moved to

the CLOSED position to start

the engine, gradually push it to

the OPEN position as the engine

warms up.

ENGINE SWITCH

OFFON

STARTER GRIP

Direction to pull

CHOKE ROD

OPEN

CLOSED

23

Page 26: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 24 ページ 2016年9月8日 木曜日 午後8時45分

OPERATION

STOPPING THE ENGINE

To stop the engine in an emergency, simply turn the engine switch to

the OFF position. Under normal conditions, use the following procedure.

1. Turn off or disconnect all appliances that are connected to the generator.

2. Switch the AC circuit breaker to

the OFF position.

3. Turn the engine switch to the

OFF position.

4. Turn the fuel valve lever to the

OFF position.

AC CIRCUIT BREAKER

OFF

OFF ON

ENGINE SWITCH

ON

OFF

FUEL VALVE LEVER

24

Page 27: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 25 ページ 2016年9月8日 木曜日 午後8時45分

OPERATION

GFCI OPERATION CHECK

Always check GFCI operation before using the generator.

1. Unplug all tools and appliances from the generator.

2. Start the engine (see page 22).

3. Turn the AC circuit breaker to the ON position.

4. Press the GFCI TEST button. The LED comes on, and the AC circuit

breaker switches to the OFF position.

A faulty GFCI system will not provide proper protection against electric shock as designed.

An electric shock can result in serious injury or death.

Always perform the GFCI system inspection before using the generator. If the GFCI system fails the test, the generator must be repaired by an authorized Honda servicing dealer before use.

GFCI TEST BUTTON

LED

AC CIRCUIT BREAKER

OFF

25

Page 28: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 26 ページ 2016年9月8日 木曜日 午後8時45分

OPERATION

5. When you switch the AC circuit breaker to the ON position, LED will

turn off.

If the GFCI and AC circuit breaker do not function as described, take

the generator to an authorized Honda generator dealer for repair.

During generator use, if the AC circuit breaker trips, this usually

indicates a faulty power tool, appliance, or cord.

If that occurs, perform test steps 1 through 5 to verify that the GFCI

and AC circuit breaker are in proper working order. If the GFCI and

AC circuit breaker do test correctly, then the fault is likely to be in

the power tool, appliance, or cord. Repair or replace the faulty

power tool, appliance, or cord before further use.

LED

AC CIRCUIT BREAKER

ON

26

Page 29: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 27 ページ 2016年9月8日 木曜日 午後8時45分

OPERATION

AC OPERATION

If an appliance begins to operate abnormally, becomes sluggish, or stops suddenly, turn it off immediately. Disconnect the appliance, and determine whether the problem is in the appliance or the rated load capacity of the generator has been exceeded.

Substantial overloading may damage the generator. Marginal overloading may shorten the service life of the generator.

1. Start the engine (see page 22) and make sure the output indicator

(green) comes on.

2. Switch ON the AC circuit breaker.

OUTPUT INDICATOR (GREEN)

AC CIRCUIT BREAKER

ON

27

Page 30: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 28 ページ 2016年9月8日 木曜日 午後8時45分

OPERATION

3. Plug in the appliance.

Most motorized appliances require more than their rated wattage for startup.

Do not exceed the current limit specified for any one receptacle. If an overloaded circuit causes the AC circuit breaker to switch OFF, reduce the electrical load on the circuit, wait a few minutes and then reset the AC circuit breaker.

If there is a short circuit in a connected appliance, or if the inverter is

overheated, the output indicator (green) will blink and current to the

connected appliance(s) will shut off. Stop the engine and investigate

the problem.

Determine if the cause is a short circuit in a connected appliance, or

an overheated inverter. Correct the problem and restart the generator.

Before connecting an appliance to the generator, make sure that it is

in good order and that its electrical rating does not exceed that of the

generator. Then start the generator and connect the appliance power

cord.

If the output indicator (green) blinks again, consult your Honda

generator dealer.

28

Page 31: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 29 ページ 2016年9月8日 木曜日 午後8時45分

OPERATION

AC Applications

Before connecting an appliance or power cord to the generator:

• Make sure that it is in good working order. A faulty appliance or

power cord can create a potential for electrical shock.

• If an appliance begins to operate abnormally, becomes sluggish, or

stops suddenly, turn it off immediately. Disconnect the appliance,

and determine whether the problem is the appliance or the rated

load capacity of the generator has been exceeded.

Most appliance motors require more than their rated wattage for

startup. Make sure the electrical rating of the tool or appliance does not

exceed the maximum power rating of the generator.

Maximum power is:

3.0 kVA

For continuous operation, do not exceed the rated power. Rated power is:

2.6 kVA

In either case, the total power requirements (VA) of all appliances

connected must be considered. Appliance and power tool

manufacturers usually list rating information near the model number

or serial number.

Substantial overloading will open the circuit breaker. Slightly

overloading the generator may not switch the circuit breaker OFF, but

will shorten the service life of the generator.

29

Page 32: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 30 ページ 2016年9月8日 木曜日 午後8時45分

OPERATION

STANDBY POWER

Connections to a Building’s Electrical System

Do not connect an EB3000c generator to a home or building’s

electrical system.

The Honda EB3000c generator is designed for construction job site

use and cannot be connected to a building’s electrical system. This

generator has the neutral bonded to ground to comply with OSHA job

site temporary power regulation. Building main breaker boxes also

have the neutral bonded to ground, so if an EB3000c generator is

connected to a home or building electrical system, the GFCI relay will

trip the generator’s main circuit breaker.

System Ground

This generator has a system ground that connects generator frame

components to ground terminals in the AC output receptacles. The

system ground is connected to the AC neutral wire.

Special Requirements

There may be Federal or State Occupational Safety and Health

Administration (OSHA) regulations, local codes, or ordinances that

apply to the intended use of the generator. Please consult a qualified

electrician, electrical inspector, or the local agency having jurisdiction.

• In some areas, generators are required to be registered with local

utility companies.

• If the generator is used at a construction site, there may be

additional regulations that must be observed.

30

Page 33: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 31 ページ 2016年9月8日 木曜日 午後8時45分

SERVICING YOUR GENERATOR

THE IMPORTANCE OF MAINTENANCE

Good maintenance is essential for safe, economical, and trouble free operation. It will also help reduce air pollution.

To help you properly care for your generator, the following pages include a maintenance schedule, routine inspection procedures, and simple maintenance procedures using basic hand tools. Other service tasks that are more difficult or require special tools are best handled by professionals and are normally performed by a Honda technician or other qualified mechanic.

The maintenance schedule applies to normal operating conditions. If you operate your generator under unusual conditions, such as sustained high-load or high-temperature operation, or use it in dusty conditions, consult your servicing dealer for recommendations applicable to your individual needs and use.

Remember that an authorized Honda servicing dealer knows your generator best and is fully equipped to maintain and repair it.

To ensure the best quality and reliability, use only new, Honda Genuine parts or their equivalents for repair and replacement.

Maintenance, replacement, or repair of the emission control devices

and systems may be performed by any engine repair establishment or

individual, using parts that are ‘‘certified’’ to EPA standards.

Failure to properly maintain this generator, or failing to correct a problem before operation, could result in a significant malfunction.

Some malfunctions can seriously hurt or kill you.

Always follow the inspection and maintenance recommendations and schedules in this owner's manual.

31

Page 34: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 32 ページ 2016年9月8日 木曜日 午後8時45分

SERVICING YOUR GENERATOR

MAINTENANCE SAFETY

Some of the most important safety precautions follow. However, we cannot warn you of every conceivable hazard that can arise in performing maintenance. Only you can decide whether or not you should perform a given task.

Safety Precautions

Make sure the engine is off before you begin any maintenance or

repairs. This will eliminate several potential hazards:

– Carbon monoxide poisoning from engine exhaust. Be sure there is adequate ventilation whenever you operate the

engine.

– Burns from hot parts. Let the engine and exhaust system cool before touching.

– Injury from moving parts. Do not run the engine unless instructed to do so.

• Read the instructions before you begin, and make sure you have the

tools and skills required.

• To reduce the possibility of fire or explosion, be careful when

working around gasoline. Use only a non-flammable solvent, not

gasoline, to clean parts. Keep cigarettes, sparks, and flames away

from all fuel-related parts.

Improper maintenance can cause an unsafe condition.

Failure to properly follow maintenance instructions and precautions can cause you to be seriously hurt or killed.

Always follow the procedures and precautions in this owner's manual.

32

Page 35: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 33 ページ 2016年9月8日 木曜日 午後8時45分

SERVICING YOUR GENERATOR

MAINTENANCE SCHEDULE

(*) Replace paper element type only.

(1) Service more frequently when used in dusty areas.

(2) These items should be serviced by your servicing dealer, unless you have the

proper tools and are mechanically proficient. Refer to the Honda shop manual for

service procedures. See ‘‘Honda Publications’’ on page 62 for ordering information.

(3) For commercial use, log hours of operation to determine proper maintenance

intervals.

Failure to follow this maintenance schedule could result in non-warrantable failures.

Each

use

First

month

or

20 Hrs.

Every

3 months

or

50 Hrs.

Every

6 months

or

100 Hrs.

Every

year

or

300 Hrs.

Page

Engine oil Check level o 36

Change o o 37

Air cleaner Check o 39

Clean o (1) 40

Replace o (*) 39

GFCI operation Check o 25

EVAP Canister Check Every 2 years (2) —

Purge tube Check Every 2 years (2) —

Charge tube Check Every 2 years (2) —

Sediment cup Clean o 41

Spark plug Check-adjust o 43

Replace o 43

Spark arrester Clean o 45

Valve clearance Check-adjust o (2) —

Combustion

chamber

CleanAfter every 500 Hrs. (2) —

Fuel tank and filter Clean o (2) —

Fuel tube Check Every 2 years (Replace if necessary) (2) —

REGULAR SERVICE PERIOD (3)

ITEMPerform at every indicated month or operating hour interval, whichever comes first.

33

Page 36: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 34 ページ 2016年9月8日 木曜日 午後8時45分

SERVICING YOUR GENERATOR

REFUELING

With the engine stopped, check the fuel level gauge. Refill the fuel tank if the fuel level is low.

Fuel can damage paint and plastic. Be careful not to spill fuel when filling your fuel tank. Damage caused by spilled fuel is not covered under the Distributor’s Limited Warranty.

Refuel in a well-ventilated area before starting the engine. If the engine has been running, allow it to cool. Refuel carefully to avoid spilling fuel. Do not fill the fuel tank above the upper level mark (see page 35) or fuel may flow into the EVAP canister causing fuel spillage.Never refuel the engine inside a building where gasoline fumes may reach flames or sparks. Keep gasoline away from appliance pilot lights, barbecues, electric appliances, power tools, etc.Spilled fuel is not only a fire hazard, it causes environmental damage. Wipe up spills immediately.

Gasoline is highly flammable and explosive.

You can be burned or seriously injured when handling fuel.

• Stop the engine and let it cool

before handling fuel.

• Keep heat, sparks, and flame

away

• Handle fuel only outdoors

• Wipe up spills immediately

34

Page 37: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 35 ページ 2016年9月8日 木曜日 午後8時45分

SERVICING YOUR GENERATOR

After refueling, reinstall the fuel tank cap securely.

FUEL RECOMMENDATIONS

This engine is certified to operate on regular unleaded gasoline with a pump octane rating of 86 or higher.

Never use gasoline that is stale, contaminated, or mixed with oil. Avoid getting dirt or water in the fuel tank.

You may use regular unleaded gasoline containing no more than 10% ethanol (E10) or 5% methanol by volume. In addition, methanol must contain cosolvents and corrosion inhibitors.

Use of fuels with content of ethanol or methanol greater than shown above may cause starting and/or performance problems. It may also damage metal, rubber, and plastic parts of the fuel system.

Engine damage or performance problems that result from using a fuel with percentages of ethanol or methanol greater than shown above are not covered under warranty.

If your equipment will be used on an infrequent or intermittent basis, please refer to the fuel section of the STORAGE chapter (see page 46) for additional information regarding fuel deterioration.

TETHER

FULL

FUEL TANK CAP

FUEL GAUGE

EMPTY

UPPER LEVEL MARK (RED)

35

Page 38: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 36 ページ 2016年9月8日 木曜日 午後8時45分

SERVICING YOUR GENERATOR

ENGINE OIL LEVEL CHECK

Check the engine oil level with the generator on a level surface and the

engine stopped.

1. Remove the oil filler cap.

2. Check the oil level. If it is below the upper limit, fill with the

recommended oil (see page 38) to the upper limit of the oil filler

neck.

3. Reinstall the oil filler cap securely.

The Oil Alert system will automatically stop the engine before the oil

level falls below safe limits. However, to avoid the inconvenience of an

unexpected shutdown, check the oil level regularly.

OIL FILLER CAP

UPPER LIMIT

OIL FILLER NECK

36

Page 39: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 37 ページ 2016年9月8日 木曜日 午後8時45分

SERVICING YOUR GENERATOR

ENGINE OIL CHANGE

Drain the oil while the engine is warm to assure rapid and complete

draining.

1. Place a suitable container below the engine to catch the used oil,

and then remove the oil filler cap, drain plug, and sealing washer.

2. Allow the used oil to drain completely, and then reinstall the drain

plug and a new sealing washer. Tighten the plug securely.

TORQUE: 18 N∙m (1.8 kgf∙m, 13 lbf∙ft)

Improper disposal of engine oil can be harmful to the environment. If you change your own oil, please dispose of the used oil properly.

Put it in a sealed container, and take it to a recycling center. Do not

discard it in a trash bin, dump it on the ground, or pour it down the

drain.

3. With the generator in a level position, fill with the recommended oil

to the upper limit of the oil filler neck (see page 38).

Maximum oil capacity: 18 oz (0.55 L)

4. Reinstall the oil filler cap securely.

Wash your hands with soap and water after handling used oil.

SEALING WASHER (Replace)

UPPER LIMIT

OIL DRAIN PLUG

37

Page 40: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 38 ページ 2016年9月8日 木曜日 午後8時45分

SERVICING YOUR GENERATOR

ENGINE OIL RECOMMENDATIONS

Oil is a major factor affecting performance and service life. Use 4-stroke automotive detergent oil.

SAE 10W–30 is recommended for general use. Other viscosities

shown in the chart may be used when the average temperature in

your area is within the recommended range.

The SAE oil viscosity and service classification are in the API label on

the oil container. Honda recommends that you use API service

category SJ or later (or equivalent) oil.

AMBIENT TEMPERATURE

38

Page 41: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 39 ページ 2016年9月8日 木曜日 午後8時45分

SERVICING YOUR GENERATOR

AIR CLEANER SERVICE

1. Unsnap the air cleaner cover clips,

and remove the air cleaner cover.

2. Check the foam air filter and paper

air filter to be sure they are clean

and in good condition. If the foam

air filter is dirty, clean it as

described on page 40. If the paper

air filter is dirty, replace it with new

one. Do not clean the paper air

filter.

3. Reinstall the air cleaner cover.

Operating the engine without an air

filter or with a damaged air filter will

allow dirt to enter the engine, causing

rapid engine wear. This type of

damage is not covered by the

Distributor’s Limited Warranty.

AIR CLEANER COVER

CLIPS

FOAM AIR FILTER

AIR CLEANER COVER

PAPER AIR FILTER

39

Page 42: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 40 ページ 2016年9月8日 木曜日 午後8時45分

SERVICING YOUR GENERATOR

FOAM AIR FILTER CLEANING

A dirty foam air filter will restrict air flow to the carburetor, reducing

engine performance. If you operate the generator in very dusty areas,

clean the foam air filter more frequently than specified in the

Maintenance Schedule.

1. Wash the foam air filter in a solution of household detergent and

warm water, then rinse thoroughly, or wash in non-flammable or

high flash point solvent. Allow the foam air filter to dry thoroughly.

2. Soak the foam air filter in clean engine oil and squeeze out the

excess oil. The engine will smoke during initial startup if too much

oil is left in the foam air filter.

3. Wipe dirt from the air cleaner housing and cover using a moist rag.

Be careful to prevent dirt from entering the air duct that leads to the

carburetor.

Do not twist. Do not twist.Clean Squeeze and Dry Dip in Oil Squeeze

40

Page 43: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 41 ページ 2016年9月8日 木曜日 午後8時45分

SERVICING YOUR GENERATOR

SEDIMENT CUP CLEANING

The sediment cup prevents water that may be in the fuel tank from

entering the carburetor. If the engine has not been run for a long time,

the sediment cup should be cleaned.

1. Turn the engine switch to the OFF position.

2. Turn the fuel valve lever to the OFF position.

3. Unscrew the sediment cup.

Gasoline is highly flammable and explosive.

You can be burned or seriously injured when handling fuel.

• Stop the engine and let it cool

before handling fuel.

• Keep heat, sparks, and flame

away

• Handle fuel only outdoors

• Wipe up spills immediately

41

Page 44: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 42 ページ 2016年9月8日 木曜日 午後8時45分

SERVICING YOUR GENERATOR

4. Clean the sediment cup in non-flammable or high flash point

solvent.

5. Install the sediment cup and a new O-ring.

6. Turn the fuel valve to the ON position and check for leaks.

FUEL VALVE LEVER

SEDIMENT CUP O-RING (Replace)

SEDIMENT CUP

42

Page 45: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 43 ページ 2016年9月8日 木曜日 午後8時45分

SERVICING YOUR GENERATOR

SPARK PLUG SERVICE

In order to service the spark plug, you will need a spark plug wrench

(commercially available).

Recommended spark plug: BPR6ES (NGK)

W20EPR-U (DENSO)

To ensure proper engine operation, the spark plug must be properly

gapped and free of deposits.

An incorrect spark plug can cause engine damage.

If the engine is hot, allow it to cool before servicing the spark plug.

1. Remove the spark plug cap.

2. Clean any dirt from around the spark plug base.

3. Use a spark plug wrench to remove the spark plug.

SPARK PLUG WRENCH

SPARK PLUG CAP

43

Page 46: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 44 ページ 2016年9月8日 木曜日 午後8時45分

SERVICING YOUR GENERATOR

4. Visually inspect the spark plug.

Replace it if the electrodes are

worn or if the insulator is

cracked, chipped, or fouled.

5. Measure the spark plug

electrode gap with a wire-type

feeler gauge. Correct the gap, if

necessary, by carefully bending

the side electrode.

The gap should be: 0.028–0.031 in (0.7–0.8 mm)

6. Check that the spark plug sealing washer is in good condition, and

thread the spark plug in by hand to prevent cross-threading.

7. After the spark plug is seated, tighten with a spark plug wrench to

compress the washer.

If installing a new spark plug, tighten 1/2 turn after the spark plug

seats to compress the washer. If reinstalling a used spark plug,

tighten 1/8–1/4 turn after the spark plug seats to compress the

washer.

TORQUE: 18 N∙m (1.8 kgf∙m, 13 lbf∙ft)

A loose spark plug can overheat and damage the engine.

Overtightening the spark plug can damage the threads in the cylinder

head.

8. Reinstall the spark plug cap on the spark plug securely.

SIDE ELECTRODE

SEALING WASHER

0.028–0.031 in (0.7–0.8 mm)

INSULATOR

44

Page 47: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 45 ページ 2016年9月8日 木曜日 午後8時45分

SERVICING YOUR GENERATOR

SPARK ARRESTER SERVICE

If the generator has been running, the muffler will be very hot. Allow it

to cool before proceeding.

The spark arrester must be serviced every 100 hours to maintain its

efficiency.

1. Remove the 4 mm self-tapping screw, and remove the spark

arrester from the muffler.

2. Use a brush to remove carbon deposits from the spark arrester

screen.

3. Inspect the screen for breaks or tears and replace it if necessary.

4. Install the spark arrester in the reverse order of removal.

SPARK ARRESTER

4 mm SELF-TAPPING SCREW

45

Page 48: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 46 ページ 2016年9月8日 木曜日 午後8時45分

STORAGE

STORAGE PREPARATION

Proper storage preparation is essential for keeping your generator trouble-free and looking good. The following steps will help to keep rust and corrosion from impairing your generator’s function and appearance, and will make the engine easier to start when you use the generator again.

Cleaning

Wipe the generator with a moist cloth. After the generator has dried, touch up any damaged paint, and coat other areas that may rust with a light film of oil.

Fuel

Depending on the region where you operate your equipment, fuel formulations may deteriorate and oxidize rapidly. Fuel deterioration and oxidation can occur in as little as 30 days and may cause damage to the carburetor and/or fuel system. Please check with your servicing dealer for local storage recommendations.

Gasoline will oxidize and deteriorate in storage. Old gasoline will cause hard starting, and it leaves gum deposits that clog the fuel system. If the gasoline in your generator deteriorates during storage, you may need to have the carburetor and other fuel system components serviced or replaced. The length of time that gasoline can be left in your fuel tank and carburetor without causing functional problems will vary with such factors as gasoline blend, your storage temperatures, and whether the fuel tank is partially or completely filled. The air in a partially filled fuel tank promotes fuel deterioration. Very warm storage temperatures accelerate fuel deterioration. Fuel deterioration problems may occur within a few months, or even less if the gasoline was not fresh when you filled the fuel tank.

The Distributor’s Limited Warranty does not cover fuel system damage or engine performance problems resulting from neglected storage preparation. You can extend fuel storage life by adding a gasoline stabilizer that is formulated for that purpose, or you can avoid fuel deterioration problems by draining the carburetor, sediment cup (if applicable) and/ or fuel tank.

46

Page 49: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 47 ページ 2016年9月8日 木曜日 午後8時45分

STORAGE

Service according to the table below:

STORAGE TIME RECOMMENDED SERVICE PROCEDURE TO

PREVENT HARD STARTING

Less than 1 month No preparation required

1 to 2 monthsFill with fresh gasoline and add gasoline

stabilizer*.

2 months to 1 year

Fill with fresh gasoline and add gasoline

stabilizer*.

Drain the carburetor float bowl (see page 48).

Drain the fuel sediment cup (see page 41).

1 year or more

Fill with fresh gasoline and add gasoline

stabilizer*.

Drain the carburetor float bowl (see page 48).

Drain the fuel sediment cup (see page 41).

Remove the spark plug. Put a teaspoon of

engine oil into the cylinder. Turn the engine

slowly with the stater grip to distribute the oil.

Reinstall the spark plug.

Change the engine oil (see page 37).

After removal from storage, drain the stored

gasoline into a suitable container, and fill with

fresh gasoline before starting.

*Use gasoline stabilizers that are formulated to extend storage life.

Follow the manufacturer’s instructions for use.

Contact your authorized Honda generator dealer for stabilizer

recommendations.

47

Page 50: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 48 ページ 2016年9月8日 木曜日 午後8時45分

STORAGE

Draining the Fuel Tank and Carburetor

1. Place a suitable gasoline container below the carburetor.

2. Turn the fuel valve lever to the

OFF position, loosen the

carburetor drain bolt by turning 1

to 2 turns counterclockwise, and

drain the fuel from the carburetor.

3. Remove the sediment cup (see

page 41), and then turn the fuel

valve lever to the ON position and

drain the fuel from the fuel tank.

4. After all the fuel has drained into the container, tighten the

carburetor drain bolt securely.

5. Install the sediment cup and a new O-ring.

6. Turn the fuel valve lever to the OFF position.

Gasoline is highly flammable and explosive.

You can be burned or seriously injured when handling fuel.

• Stop the engine and let it cool

before handling fuel.

• Keep heat, sparks, and flame

away

• Handle fuel only outdoors

• Wipe up spills immediately

CARBURETOR DRAIN BOLT

48

Page 51: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 49 ページ 2016年9月8日 木曜日 午後8時45分

STORAGE

Engine Oil

Change the engine oil (see page 37).

Engine Cylinder

1. Remove the spark plug (see page 43).

2. Pour a teaspoon (5 cc) of clean engine oil into the cylinder.

3. Pull the starter rope several times to distribute the oil in the cylinder.

4. Reinstall the spark plug (see page 44).

5. Slowly pull the starter grip until resistance is felt. At this point, the

piston is coming up on its compression stroke and both the intake

and exhaust valves are closed. Storing the engine in this position will

help to protect it from internal corrosion. Return the starter grip

gently.

49

Page 52: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 50 ページ 2016年9月8日 木曜日 午後8時45分

STORAGE

STORAGE PRECAUTIONS

If your generator will be stored with gasoline in the fuel tank and

carburetor, it is important to reduce the hazard of gasoline vapor

ignition.

Select a well ventilated storage area away from any appliance that

operates with a flame, such as a furnace, water heater, or clothes dryer.

Also avoid any area with a spark-producing electric motor, or where

power tools are operated.

If possible, avoid storage areas with high humidity, because that

promotes rust and corrosion.

Unless all fuel has been drained from the fuel tank, leave the fuel valve

in the OFF position to reduce the possibility of leakage.

Place the generator on a level surface. Tilting can cause fuel or oil

leakage.

With the engine and exhaust system cool, cover the generator to keep

out dust. A hot engine and exhaust system can ignite or melt some

materials.

Do not use a plastic sheet as a dust cover. A nonporous cover will trap

moisture around the generator, promoting rust and corrosion.

REMOVAL FROM STORAGE

Check your generator as described in the BEFORE OPERATION chapter

of this manual.

If the generator was stored for 1 year or longer, drain the fuel tank (see

page 48) and refuel with fresh gasoline. If you keep a container of

gasoline for refueling, be sure that it contains only fresh gasoline.

Gasoline oxidizes and deteriorates over time, causing hard starting.

If the cylinder was coated with oil during storage preparation, the

engine may smoke briefly at startup. This is normal.

50

Page 53: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 51 ページ 2016年9月8日 木曜日 午後8時45分

TRANSPORTING

Do not lay the generator on its side when moving, storing, or

operating it. Oil or fuel may leak and damage the engine or your

property.

If the generator has been used, allow it cool for at least 15 minutes

before loading the generator on the transport vehicle. A hot engine

and exhaust system can burn you and can ignite some material. When transporting the generator, turn the engine switch and the fuel

valve lever OFF, and keep the generator level to reduce the possibility

of fuel leakage. Take care not to drop or strike the generator when transporting. Do

not place heavy objects on the generator.

51

Page 54: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 52 ページ 2016年9月8日 木曜日 午後8時45分

TAKING CARE OF UNEXPECTED PROBLEMS

ENGINE WILL NOT START

ENGINE LACKS POWER

Possible Cause Correction

Fuel valve lever OFF. Turn lever ON (see page 22).

Engine switch OFF. Turn engine switch to ON

(see page 23).

Out of fuel. Refuel (see page 34).

Bad fuel; generator stored

without treating or draining

gasoline, or refueled with bad

gasoline.

Drain fuel tank and carburetor (see page 48).

Refuel with fresh gasoline (see page 34).

Low oil level caused Oil Alert to

stop engine.

Check oil level and add oil as

necessary (see page 36).

Turn engine switch to OFF and

then restart the engine.

Spark plug faulty, fouled, or

improperly gapped.

Gap or replace spark plug (see page 43).

Spark plug wet with fuel (flooded engine).

Dry and reinstall spark plug.

Fuel filter restricted, carburetor

malfunction, ignition

malfunction, valves stuck, etc.

Take the generator to an

authorized Honda servicing

dealer, or refer to the shop

manual.

Possible Cause Correction

Air filter restricted. Clean or replace air filter (see pages 39, 40).

Bad fuel; generator stored

without treating or draining

gasoline, or refueled with bad

gasoline.

Drain fuel tank and carburetor (see page 48).

Refuel with fresh gasoline (see page 34).

Fuel filter restricted, carburetor

malfunction, ignition

malfunction, valves stuck, etc.

Take the generator to an

authorized Honda servicing

dealer, or refer to the shop

manual.

52

Page 55: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 53 ページ 2016年9月8日 木曜日 午後8時45分

TAKING CARE OF UNEXPECTED PROBLEMS

NO POWER AT THE AC RECEPTACLES

Possible Cause Correction

Output indicator blinks. Check AC load. Stop and restart

the engine.

Check the cooling air inlet. Stop

and restart the engine.

AC circuit breaker left in the OFF

position after starting.

Check AC load and reset AC

circuit breaker (see page 27).

GFCI activated. Test GFCI (see page 25) and reset

AC circuit breaker.

Replace faulty power tool or

appliance.

AC circuit protector tripped. Check AC load and reset circuit

protector (see page 12).

Faulty power tool or appliance. Replace or repair power tool or

appliance.

Stop and restart the engine.

Faulty generator. Take the generator to an

authorized Honda servicing

dealer, or refer to the shop

manual.

53

Page 56: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 54 ページ 2016年9月8日 木曜日 午後8時45分

TECHNICAL INFORMATION

Serial Number Location

Record the frame serial number in the space below. You will need this

serial number when ordering parts, and when making technical or

warranty inquiries.

Frame serial number:

Date purchased:

FRAME SERIAL NUMBER

54

Page 57: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 55 ページ 2016年9月8日 木曜日 午後8時45分

TECHNICAL INFORMATION

Carburetor Modification for High Altitude Operation

At high altitude, the standard carburetor air-fuel mixture will be too

rich. Performance will decrease, and fuel consumption will increase. A

very rich mixture will also foul the spark plug and cause hard starting.

Operation at an altitude that differs from that at which this engine was

certified, for extended periods of time, may increase emissions.

High altitude performance can be improved by specific modifications

to the carburetor. If you always operate your generator at altitudes

above 5,000 feet (1,500 meters), have your authorized Honda

servicing dealer perform this carburetor modification. This engine,

when operated at high altitude with the carburetor modifications for

high altitude use, will meet each emission standard throughout its

useful life.

Even with carburetor modification, engine horsepower will decrease

about 3.5% for each 1,000-foot (300-meter) increase in altitude. The

effect of altitude on horsepower will be greater than this if no

carburetor modification is made.

When the carburetor has been modified for high altitude operation,

the air/fuel mixture will be too lean for low altitude use. Operation at

altitudes below 5,000 feet (1,500 meters) with a modified carburetor

may cause the engine to overheat and result in serious engine

damage. For use at low altitudes, have your servicing dealer return

the carburetor to original factory specifications.

55

Page 58: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 56 ページ 2016年9月8日 木曜日 午後8時45分

TECHNICAL INFORMATION

Emission Control System Information

Source of Emissions

The combustion process produces carbon monoxide, oxides of nitrogen,

and hydrocarbons. Control of hydrocarbons and oxides of nitrogen are

very important because, under certain conditions, they react to form

photochemical smog when subjected to sunlight. Carbon monoxide

does not react in the same way, but it is toxic.

Honda utilizes appropriate air/fuel ratios and other emissions control

systems to reduce the emissions of carbon monoxide, oxides of

nitrogen, and hydrocarbons.

Additionally, Honda fuel systems utilize components and control

technologies to reduce evaporative emissions.

The U.S. and California Clean Air Acts

EPA and California regulations require all manufacturers to furnish

written instructions describing the operation and maintenance of

emission control systems.

The following instructions and procedures must be followed in order to

keep the emissions from your Honda engine within the emission

standards.

Tampering and Altering

Tampering is a violation of federal and California law.

Tampering with or altering the emission control system may increase

emissions beyond the legal limit. Among those acts that constitute

tampering are:

• Removal or alteration of any part of the intake, fuel, or exhaust

systems.

• Altering or defeating the governor linkage or speed-adjusting

mechanism to cause the engine to operate outside its design

parameters.

56

Page 59: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 57 ページ 2016年9月8日 木曜日 午後8時45分

TECHNICAL INFORMATION

Problems That May Affect Emissions

If you are aware of any of the following symptoms, have your engine

inspected and repaired by your authorized Honda servicing dealer.

• Hard starting or stalling after starting.

• Rough idle.

• Misfiring or backfiring under load.

• Afterburning (backfiring).

• Black exhaust smoke or high fuel consumption.

Replacement Parts

The emission control systems on your new Honda engine were

designed, built, and certified to conform with EPA and California

emission regulations. We recommend the use of genuine Honda parts

whenever you have maintenance done. These original-design

replacement parts are manufactured to the same standards as the

original parts, so you can be confident of their performance. The use

of replacement parts that are not of the original design and quality

may impair the effectiveness of your emission control system.

A manufacturer of an aftermarket part assumes the responsibility that

the part will not adversely affect emission performance. The

manufacturer or rebuilder of the part must certify that use of the part

will not result in a failure of the engine to comply with emission

regulations.

Maintenance

Follow the MAINTENANCE SCHEDUL E on page 33. Remember that

this schedule is based on the assumption that your machine will be

used for its designed purpose. Sustained high-load or high-

temperature operation, or use in dusty conditions, will require more

frequent service.

57

Page 60: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 58 ページ 2016年9月8日 木曜日 午後8時45分

TECHNICAL INFORMATION

U.S. EPA and CARB Compliance

Your new Honda complies with both the U.S. EPA and State of

California emission regulations. In all areas of the United States your

power equipment engine is designed, built, and equipped to meet the

U.S. EPA and California Air Resources Board emission standard for

spark-ignited engines.

Warranty Coverage

Honda Power Equipment engines certified to the CARB and EPA 2010

and later regulations are covered by this warranty to be free from

defects in materials and workmanship that may keep it from meeting

the applicable EPA and CARB emissions requirements for a minimum

of 2 years or 250 hours of operation, whichever comes first; or the

length of the Honda Power Equipment Distributor’s Limited Warranty,

whichever is longer, from the original date of delivery to the retail

purchaser. This warranty is transferable to each subsequent purchaser

for the duration of the warranty period. Warranty repairs will be made

without charge for diagnosis, parts, and labor. Information about how

to make a warranty claim, as well as a description of how a claim can

be made and/or service can be provided, can be had by contacting an

authorized Honda Power Equipment dealer or by contacting American

Honda at the following:

Email: [email protected] Telephone: (888) 888-3139

The covered components include all components whose failure would

increase an engine's emissions of any regulated pollutant or

evaporative emissions. A list of specific components can be found in

the separately included emission warranty statement.

Specific warranty terms, coverage, limitations, and manner of seeking

warranty service are also set forth in the separately included emission

warranty statement. In addition, the emission warranty statement can

also be found on the Honda Power Equipment website:

http://powerequipment.honda.com/support/warranty

58

Page 61: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 59 ページ 2016年9月8日 木曜日 午後8時45分

TECHNICAL INFORMATION

Air Index

(Models sold in California)

An Air Index Information label is applied to engines certified to an

emission durability time period in accordance with the requirements of

the California Air Resources Board.

The bar graph is intended to provide you, our customer, the ability to

compare the emissions performance of available engines. The lower the

Air Index, the less pollution.

The durability description is intended to provide you with information

relating to the engine’s emission durability period. The descriptive term

indicates the useful life period for the engine’s emission control system.

See your Emission Control System Warranty (see page 69) for additional

information.

Descriptive Term Applicable to Emission Durability Period

Moderate 50 hours (0–80 cc, inclusive)125 hours (greater than 80 cc)

Intermediate 125 hours (0–80 cc, inclusive)250 hours (greater than 80 cc)

Extended 300 hours (0–80 cc, inclusive)500 hours (greater than 80 cc)

1,000 hours (225 cc and greater)

59

Page 62: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 60 ページ 2016年9月8日 木曜日 午後8時45分

TECHNICAL INFORMATION

Specifications

Dimensions

Engine

Generator

Tuneup Specifications

Model (Type) EB3000cK2

Description code EZGP

Length 17.5 in (445 mm)

Width 15.8 in (402 mm)

Height 18.9 in (480 mm)

Dry mass [weight] 71.0 lbs (32.2 kg)

Model GX200T2

Engine type 4-stroke, overhead valve, single cylinder

Displacement 12.0 cu-in (196 cm3)

Bore×Stroke 2.68×2.13 in (68.0×54.0 mm)

Compression ratio 8.5:1

Engine speed 3,600 rpm

Cooling system Forced air

Ignition system Transistor magneto

Oil capacity 18 oz (0.55 L)

Fuel tank capacity 2.56 US gal (9.7 L)

Spark plug BPR6ES (NGK)W20EPR-U (DENSO)

Model EB3000cK2

Type A type

AC output

Rated voltage 120 V

Rated frequency 60 Hz

Rated ampere 21.7 A

Rated output 2.6 kVA

Maximum output 3.0 kVA

ITEM SPECIFICATION MAINTENANCE

Spark plug gap 0.028–0.031 in (0.7–0.8 mm) Refer to page: 44

Valve clearance (cold)

IN: 0.15±0.02 mmEX: 0.20±0.02 mm

See your authorized Honda dealer

Other specifications No other adjustments needed.

60

Page 63: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 61 ページ 2016年9月8日 木曜日 午後8時45分

TECHNICAL INFORMATION

Wiring Diagram

61

Page 64: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 62 ページ 2016年9月8日 木曜日 午後8時45分

CONSUMER INFORMATION

Dealer Locator Information

To find an authorized Honda Servicing Dealer anywhere in the United

States: Visit our website: http://powerequipment.honda.com/dealer-locator

Honda Publications

Shop Manual

This manual covers complete maintenance and overhaul procedures. It is intended to be used by a skilled technician. Available through your Honda dealer or visit http://powerequipment.honda.com/support/shop-manuals

Parts Catalog

This manual provides complete, illustrated parts lists. Available

through your Honda dealer.

62

Page 65: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 63 ページ 2016年9月8日 木曜日 午後8時45分

CONSUMER INFORMATION

Customer Service Information

Honda Power Equipment dealership personnel are trained professionals.

They should be able to answer any question you may have. If you

encounter a problem that your dealer does not solve to your

satisfaction, please discuss it with the dealership’s management. The Service Manager or General Manager can help. Almost all problems

are solved in this way.

If you are dissatisfied with the decision made by the dealership’s

management, contact the Honda Power Equipment Customer Relations

Office. You can write to:

American Honda Motor Co., Inc. Power Equipment Division Customer Relations Office 4900 Marconi Drive Alpharetta, Georgia 30005-8847

Or telephone:(770) 497-6400 8:30 am to 7:00 pm ET

When you write or call, please give us this information:

• Model and serial number (see page 54)

• Name of the dealer who sold the Generator to you

• Name and address of the dealer who services your Generator

• Date of purchase

• Your name, address, and telephone number

• A detailed description of the problem

63

Page 66: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 64 ページ 2016年9月8日 木曜日 午後8時45分

CONSUMER INFORMATION

Distributor’s Limited Warranty

This warranty is limited to the following Honda Power Equipment

products when distributed by American Honda Motor Co., Inc., Power

Equipment Division, 4900 Marconi Drive, Alpharetta, Georgia 30005-8847. The following warranty applies to products purchased at

retail or placed in rental service on or after January 1, 2010.

(1) Private residential: Used in maintaining owner’s primary and/or

secondary residence. Any other use, including but not limited to

informal ‘‘for hire’’ use, is considered commercial/rental/

institutional use.

To Qualify for this Warranty:

The product must be purchased in the United States, Puerto Rico, or

the U.S. Virgin Islands from American Honda or a dealer authorized by

American Honda to sell those products. This warranty applies to the

first retail purchaser and each subsequent owner during the applicable

warranty time period.

What American Honda will Repair or Replace Under Warranty:

American Honda will repair or replace, at its option, any part that is

proven to be defective in material or workmanship under normal use

during the applicable warranty time period. Warranty repairs and

replacements will be made without charge for parts or labor. Anything

replaced under warranty becomes the property of American Honda

Motor Co., Inc. All parts replaced under warranty will be considered as

part of the original product, and any warranty on those parts will

expire coincident with the original product warranty.

PRODUCTS COVEREDBY THIS WARRANTY

LENGTH OF WARRANTY

(from date of original retail purchase)

PRIVATE

RESIDENTIAL (1)

COMMERCIAL/RENTAL/INSTITUTIONAL

EB3000c generator 36 months 36 months

64

Page 67: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 65 ページ 2016年9月8日 木曜日 午後8時45分

CONSUMER INFORMATION

To Obtain Warranty Service:

You must, at your expense, take the Honda Power Equipment product,

accessory, replacement part, apparel, or the power equipment on

which the accessory or replacement part is installed, and proof of

purchase to any Honda Power Equipment dealer in the United States,

Puerto Rico, or the U.S. Virgin Islands who is authorized to sell that

product, during the dealer’s normal business hours. To locate a dealer

near you, visit our web site at http://powerequipment.honda.com/

dealer-locator/. If you are unable to obtain warranty service or are

dissatisfied with the warranty service you receive, contact the owner

of the dealership involved; normally this will resolve the problem.

However, if you should require further assistance, write or call the

Power Equipment Customer Relations Dept. of American Honda Motor

Co., Inc. at the following address:

American Honda Motor Co., Inc.

Power Equipment Customer Relations Dept.

4900 Marconi Drive

Alpharetta, GA 30005-8847 Telephone: (770) 497-6400

65

Page 68: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 66 ページ 2016年9月8日 木曜日 午後8時45分

CONSUMER INFORMATION

Exclusions:

1. Any damage or deterioration resulting from the following:– Neglect of the periodic maintenance as specified in this manual– Improper repair or maintenance– Operating methods other than those indicated in this manual– The use of non-genuine Honda parts and accessories other than

those approved by Honda (other than recommended lubricants and fluids)

– Exposure of the product to soot and smoke, chemical agents, bird droppings, sea water, sea breeze, salt or other environmental phenomena

– Collision, fuel contamination or deterioration, neglect, unauthorized alteration, misuse, incorporation or use of unsuitable attachments or parts

– Natural wear and tear (natural fading of painted or plated surfaces, sheet peeling and other natural deterioration)

2. Consumable parts: Honda does not warrant parts deterioration due to natural wear and tear. The parts listed below are not covered by warranty (unless they are needed as a part of another warranted repair):– Spark plug, fuel filter, air cleaner element, clutch disc, tire, wheel

bearing, recoil starter rope, cable, belt, cutter blade.– Lubricant: oil and grease.

3. Cleaning, adjustment, and normal periodic maintenance work (carburetor cleaning, engine oil draining, blade sharpening, belt and cable adjustments).

4. Any product that has ever been declared a total loss or sold for salvage by a financial institution or insurer.

5. Auger and paddle assemblies of snowthrowers, tiller tines of rototillers, mower blades and mower deck housings, are specifically not warranted against impact damage, including but not limited to, abrasive damage.

Disclaimer of Consequential Damage and Limitation of Implied Warranties:

American Honda disclaims any responsibility for loss of time or use of the product, transportation, commercial loss, or any other incidental or consequential damage. Any implied warranties are limited to the duration of this written limited warranty. Some states do not allow limitations on how long an implied warranty lasts and/or do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusions and limitations may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

66

Page 69: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 67 ページ 2016年9月8日 木曜日 午後8時45分

CONSUMER INFORMATION

Honda Accessories, Replacement Parts, And Apparel

This warranty is limited to Honda Power Equipment parts, accessories, and apparel when distributed by American Honda Motor Co., Inc., 4900 Marconi Drive, Alpharetta, Georgia 30005-8847.

To Qualify for This Warranty:1. The accessories, replacement parts, or apparel must be purchased

from American Honda, or a dealer, distributor, or distributor’s dealer authorized by American Honda to sell those products in the United States, Puerto Rico, and the U.S. Virgin Islands. Parts and Accessories must be purchased for installation on original Honda equipment or engines to be eligible for warranty coverage. Installing parts and accessories on non-Honda products or engines voids this warranty.

2. You must be the first retail purchaser. This warranty is not transferable to subsequent owners.

What American Honda Will Repair or Replace Under Warranty:

American Honda will repair or replace, at its option, any Honda Power Equipment accessories, replacement parts, or apparel that are proven to be defective in material or workmanship under normal use during the applicable warranty time period. Anything replaced under warranty becomes the property of American Honda Motor Co., Inc. All parts replaced under warranty will be considered as part of the original product, and any warranty on those parts will expire coincident with the original product warranty. Accessories and replacement parts installed by a dealer, distributor, or distributor’s dealer who is authorized by American Honda to sell them will be repaired or replaced under warranty without charge for parts or labor. If installed by anyone else, accessories and replacement parts will be repaired or replaced under warranty without charge for parts, but any labor charges will be the responsibility of the purchaser. Apparel will be repaired or replaced under warranty without any charge.

PRODUCTS COVEREDBY THIS WARRANTY

LENGTH OF WARRANTY

(from date of original retail purchase)

PRIVATE

RESIDENTIAL

COMMERCIAL/RENTAL/INSTITUTIONAL

Accessories 12 months 3 months

Replacement parts 6 months 3 months

Apparel 6 months 3 months

67

Page 70: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 68 ページ 2016年9月8日 木曜日 午後8時45分

CONSUMER INFORMATION

To Obtain Warranty Service:

You must, at your expense, take the Honda Power Equipment

accessory, replacement part, apparel, or the Honda Power Equipment

on which the accessory or replacement part is installed, and proof of

purchase to any Honda Power Equipment dealer, distributor, or

distributor’s dealer in the United States, Puerto Rico, or the U.S. Virgin

Islands who is authorized to sell that product, during the dealer’s or

distributor’s normal business hours. To locate a dealer near you, go to

our web site at http://powerequipment.honda.com/dealer-locator/. If

you are unable to obtain warranty service or are dissatisfied with the

warranty service you receive, contact the owner of the dealership or

distributorship involved; normally this will resolve the problem.

However, if you should require further assistance, write or call the

Power Equipment Customer Relations Department of America Honda

Motor Co., Inc. Refer to page 65 for contact information.

Exclusions:

This warranty does not extend to accessories, parts, or apparel

affected or damaged by collision, normal wear, use in an application for

which the product was not designed or any other misuse, neglect,

incorporation or use of unsuitable attachments or parts, unauthorized

alteration, improper installation, or any causes other than defects in

material or workmanship of the product. Installing Parts and

Accessories on non-Honda products or engines voids this warranty.

Disclaimer of Consequential Damage and Limitation of Implied Warranties:

American Honda disclaims any responsibility for loss of time or use of

the product, or the power equipment on which the product is installed,

transportation, commercial loss, or any other incidental or

consequential damage. Any implied warranties are limited to the

duration of this written warranty. Some states do not allow limitations

on how long an implied warranty lasts and/or do not allow the

exclusion or limitation of incidental or consequential damages, so the

above exclusions and limitations may not apply to you. This warranty

gives you specific legal rights, and you may also have other rights

which vary from state to state.

68

Page 71: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 69 ページ 2016年9月8日 木曜日 午後8時45分

CONSUMER INFORMATION

Emission Control System Warranty

Your new Honda Power Equipment engine complies with the U.S. EPA,

Environment Canada, and State of California (models certified for sale

in California only) emission regulations. American Honda Motor Co., Inc. provides the emission warranty coverage for engines in the

United States and its territories. Honda Canada Inc. provides the

emission warranty for engines in the 13 provinces and territories of

Canada. In the remainder of this Emission Control System Warranty,

American Honda Motor Co., Inc. and Honda Canada Inc. will be referred

to as Honda.

Your Warranty Rights And Obligations

California

The California Air Resources Board and Honda are pleased to explain the emission control system warranty on your 2016 and later Honda

Power Equipment engine. In California, new spark-ignited small off-road

equipment engines must be designed, built, and equipped to meet the

state’s stringent anti-smog standards. Specific Honda products that do

not meet the California emissions regulations can be identified by a ‘‘Not

for sale in California’’ decal.

Other States, U.S. territories, and Canada

In other areas of the United States and in Canada, your engine must be

designed, built, and equipped to meet the U.S. EPA and Environment

Canada emission standards for spark-ignited engines at or below 19

kilowatts.

All of the United States and Canada

Honda must warrant the emission control system on your power

equipment engine for the period of time listed below, provided there

has been no abuse, neglect, or improper maintenance of your power

equipment engine. Where a warrantable condition exists, Honda will

repair your power equipment engine at no cost to you including

diagnosis, parts, and labor.

Your emission control system may include such parts as the carburetor

or fuel injection system, the ignition system, and catalytic converter.

Also included may be hoses, connectors, and other emission-related

assemblies (see page 73 for additional covered parts).

69

Page 72: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 70 ページ 2016年9月8日 木曜日 午後8時45分

CONSUMER INFORMATION

Owner’s Warranty Responsibility

As the power equipment engine owner, you are responsible for

completing all required maintenance listed in your owner’s manual.

Honda recommends that you retain all receipts covering maintenance

on your power equipment engine, but Honda cannot deny warranty

coverage solely for the lack of receipts or for your failure to ensure

that all scheduled maintenance has been completed.

As the power equipment engine owner, you should however be aware

Honda may deny you warranty coverage if your power equipment

engine or a part has failed due to abuse, neglect, improper

maintenance, or unapproved modifications.

You are responsible for presenting your power equipment engine to a

Honda Power Equipment dealer as soon as a problem exists. The

emission related warranty repairs should be completed in a reasonable

amount of time, not to exceed 30 days.

If you have any questions regarding your emission warranty rights and

responsibilities, you should contact the Honda office in your region:

American Honda Motor Co., Inc. Honda Canada Inc.

Power Equipment Customer Power Equipment Relations Customer Relations

4900 Marconi Drive or 180 Honda Blvd,

Alpharetta, Georgia 30005-8847 Markham, ON L6C 0H9

Telephone: (888) 888-3139 Telephone: (888) 946-6329

Email: powerequipmentemissions

@ahm.honda.com

70

Page 73: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 71 ページ 2016年9月8日 木曜日 午後8時45分

CONSUMER INFORMATION

Warranty Coverage

Honda power equipment engines sold in the United States and Canada

are covered by this warranty for a period of two years from the date of

delivery to the original retail purchaser or the length of the Honda

Distributor’s Limited Warranty, whichever is longer. This warranty is

transferable to each subsequent purchaser for the duration of the

warranty period.

If any emission-related part on your engine is defective, the part will be

repaired or replaced by Honda without charge for diagnosis, parts, or

labor. All defective parts replaced under this warranty become the

property of Honda. Only Honda-approved replacement parts may be

used in the performance of any warranty repairs and must be provided

without charge to the owner. A list of warranted parts is on page 73.

Normal maintenance items, such as spark plugs and filters, that are on

the warranted parts list are warranted up to their required replacement

interval only.

Honda will also replace other engine components damaged by a failure

of any warranted part during the warranty period.

The use of replacement parts not equivalent to the original parts may

impair the effectiveness of your engine emission control system. If

such a replacement part is used in the repair or maintenance of your

engine, and an authorized Honda dealer determines it is defective or

causes a failure of a warranted part, your claim for repair of your

engine may be denied. If the part in question is not related to the

reason your engine requires repair, your claim will not be denied.

71

Page 74: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 72 ページ 2016年9月8日 木曜日 午後8時45分

CONSUMER INFORMATION

To Obtain Warranty Service

You must, at your own expense, take your Honda Power Equipment

engine or the product on which it is installed, along with your sales

registration card or other proof of original purchase date, to any Honda

Power Equipment dealer who is authorized by Honda to sell and service

that Honda product during their normal business hours. Claims for

repair or adjustment found to be caused solely by defects in material or

workmanship will not be denied because the engine was not properly

maintained and used.

If you are unable to obtain emission warranty service or are dissatisfied

with the warranty service you received, contact the owner of the

dealership involved. Normally this should resolve your problem.

However, if you require further assistance, contact the Honda office in

your region:

American Honda Motor Co., Inc. Honda Canada Inc.

Power Equipment Customer Power Equipment Relations Customer Relations

4900 Marconi Drive or 180 Honda Blvd,

Alpharetta, Georgia 30005-8847 Markham, ON L6C 0H9

Telephone: (888) 888-3139 Telephone: (888) 946-6329

Email: powerequipmentemissions

@ahm.honda.com

Exclusions

Failures other than those resulting from defects in material or

workmanship are not covered by this warranty. This warranty does not

extend to emission control systems or parts that are affected or

damaged by owner abuse, neglect, improper maintenance, misuse,

misfueling, improper storage, collision, the incorporation of, or use of,

unsuitable attachments, or the unauthorized alteration of any part.

This warranty does not cover replacement of expendable maintenance

items made in connection with required maintenance service after the

item’s first scheduled replacement as listed in the maintenance section

of the product owner’s manual, such as: spark plugs and filters.

72

Page 75: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 73 ページ 2016年9月8日 木曜日 午後8時45分

CONSUMER INFORMATION

Disclaimer of Consequential Damage and Limitation of Implied Warranties

American Honda Motor Co., Inc. and Honda Canada Inc. disclaim any

responsibility for incidental or consequential damages such as loss of

time or the use of the power equipment, or any commercial loss due to

the failure of the equipment; and any implied warranties are limited to

the duration of this written warranty. This warranty is applicable only

where the California, U.S. EPA, or Environment Canada emission

control system warranty regulation is in effect.

Emission Control System Warranty Parts

Note: This list applies to parts supplied by Honda and does not cover

parts supplied by the equipment manufacturer. Please see the original

equipment manufacturer’s emissions warranty for non-Honda parts. *Covered up to the first required replacement only. See the MAINTENANCE SCHEDULE on page 33.

SYSTEMS COVEREDBY THIS WARRANTY:

PARTSDESCRIPTION:

Fuel Metering Carburetor assembly (includes starting enrichment system), Oxygen sensor, Throttle body, Engine temperature sensor, Engine control module, Fuel injector, Fuel regulator, Intake manifold

Evaporative Fuel tank, Fuel cap, Fuel hoses, Vapor hoses, Carbon canister, Canister mounting brackets, Fuel strainer, Fuel valve, Fuel pump, Fuel hose joint, Canister purge hose joint

Exhaust Catalyst, Exhaust pipe, Muffler (with catalyst)

Air Induction Air cleaner case, Air cleaner element*

Ignition Flywheel comp., Flywheel magneto, Ignition pulse generator, Crankshaft position sensor, Power coil, Ignition coil assembly, Ignition control module, Spark plug cap, Spark plug*

Crankcase Emission Control

Crankcase breather tube, Breather valve assembly, Oil filler cap

Miscellaneous Parts Tubing, fittings, seals, gaskets, and clamps associated with these listed systems.

73

Page 76: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 74 ページ 2016年9月8日 木曜日 午後8時45分

INITIAL USE INSTRUCTIONS

ENGINE OIL

The generator is shipped WITHOUT OIL in the engine.

1. Place the generator on a level surface.

2. Remove the oil filler cap.

3. Add enough oil to bring the oil level to the upper limit of the oil filler

neck. SAE 10W-30 API service category SJ or later (or equivalent) is

recommended for general use; for additional recommendations (see

page 38).

Maximum oil capacity: 18 oz (0.55 L)

Do not overfill the engine with oil. If the engine is overfilled, the

excess oil may be transferred to the air cleaner housing and air filter.

4. Reinstall the oil filler cap securely.

OIL FILLER CAP

UPPER LIMIT

74

Page 77: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 75 ページ 2016年9月8日 木曜日 午後8時45分

INITIAL USE INSTRUCTIONS

FUEL

Add fuel to the generator in a well-ventilated area. Never refuel the engine inside a building where gasoline fumes may reach flames or sparks. Keep gasoline away from appliance pilot lights, barbecues, electric appliances, power tools, etc. Spilled fuel is not only a fire hazard, it causes environmental damage. Wipe up spills immediately.

This engine is certified to operate on unleaded gasoline with a pump octane rating of 86 or higher. Refer to page 35 for additional fuel recommendations.

1. Remove the fuel tank cap.

2. Fuel carefully to avoid spilling fuel.

3. Do not fill the fuel tank above the upper level mark (red) on the fuel filter or fuel may flow into the EVAP canister causing fuel spillage.

4. After refueling, reinstall the fuel tank cap securely.

Gasoline is highly flammable and explosive.

You can be burned or seriously injured when handling fuel.

• Stop the engine and let it cool

before handling fuel.

• Keep heat, sparks, and flame

away

• Handle fuel only outdoors

• Wipe up spills immediately

FUEL TANK CAP

UPPER LEVEL MARK (RED)

FUEL FILTER

UPPER LEVEL MARK (RED)

TETHER

75

Page 78: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 76 ページ 2016年9月8日 木曜日 午後8時45分

INITIAL USE INSTRUCTIONS

Fuel can damage paint and plastic. Be careful not to spill fuel when

filling your fuel tank. Damage caused by spilled fuel is not covered

under the Distributor’s Limited Warranty.

Move the generator at least 10 feet (3 meters) away from the fueling

source and site before starting the engine.

BEFORE OPERATION

Before using the generator, all generator operators must read the

following chapters and sections:

• GENERATOR SAFETY (see pages 6 – 8)

• CONTROLS & FEATURES (see pages 9 – 18)

• BEFORE OPERATION (see pages 19 – 20)

• OPERATION (see page 21)

• STARTING THE ENGINE (see pages 22 – 23)

• STOPPING THE ENGINE (see page 24)

• MAINTENANCE SCHEDULE (see page 33)

REGISTRATION

Please Register Your Generator

If your dealer did not collect registration information from you, please

take a few minutes and register your purchase with Honda. This allows

us to contact you with any important updates regarding your generator.

Please note registration is not required to obtain warranty service. You

can register your generator by visiting the Honda Power Equipment

website, http://powerequipment.honda.com/support and click on

Product Registration. Your information will remain confidential. It will

not be released to any other company or organization.

76

Page 79: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 77 ページ 2016年9月8日 木曜日 午後8時45分

INDEX

A

AC Applications .................................................................................. 29

AC Circuit Breaker............................................................................... 13

AC Circuit Protector ............................................................................ 12

AC OPERATION................................................................................... 27

AIR CLEANER SERVICE...................................................................... 39

Air Index .............................................................................................. 59

ARE YOU READY TO GET STARTED?............................................... 19

B

BEFORE OPERATION.................................................................... 19, 76

C

Carbon Monoxide Hazards .................................................................. 6

Carburetor Modification for High Altitude Operation...................... 55

Check the Engine ................................................................................ 20

Check the GFCI.................................................................................... 20

Choke Rod ........................................................................................... 11

Cleaning............................................................................................... 46

COMPONENT & CONTROL LOCATIONS............................................ 9

Connections to a Building’s Electrical System................................. 30

CONSUMER INFORMATION.............................................................. 62

CONTENTS.............................................................................................3

CONTROLS.......................................................................................... 11

CONTROLS & FEATURES .................................................................... 9

Customer Service Information .......................................................... 63

D

Dealer Locator Information................................................................ 62

Distributor’s Limited Warranty .......................................................... 64

77

Page 80: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 78 ページ 2016年9月8日 木曜日 午後8時45分

INDEX

E

Electric Shock Hazards ......................................................................... 7

Emission Control System Information.............................................. 56

Emission Control System Warranty.................................................. 69

Engine Cylinder................................................................................... 49

ENGINE LACKS POWER..................................................................... 52

Engine Oil ...................................................................................... 49, 74

ENGINE OIL CHANGE......................................................................... 37

ENGINE OIL LEVEL CHECK ................................................................ 36

ENGINE OIL RECOMMENDATIONS.................................................. 38

Engine Switch ..................................................................................... 11

ENGINE WILL NOT START................................................................. 52

F

FEATURES........................................................................................... 15

Fire and Burn Hazards.......................................................................... 7

FOAM AIR FILTER CLEANING ........................................................... 40

Fuel ................................................................................................ 46, 75

Fuel Gauge .......................................................................................... 18

FUEL RECOMMENDATIONS.............................................................. 35

Fuel Valve Lever.................................................................................. 11

G

GENERATOR SAFETY .......................................................................... 6

GFCI OPERATION CHECK .................................................................. 25

Ground Fault Circuit Interrupter (GFCI) ............................................ 14

Ground Terminal ................................................................................ 15

H

Honda Publications............................................................................. 62

I

IMPORTANT SAFETY INFORMATION ................................................ 6

INDEX .................................................................................................. 77

INITIAL USE INSTRUCTIONS ............................................................ 74

IS YOUR GENERATOR READY TO GO?............................................ 19

K

Knowledge .......................................................................................... 19

78

Page 81: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 79 ページ 2016年9月8日 木曜日 午後8時45分

INDEX

M

MAINTENANCE SAFETY.................................................................... 32

MAINTENANCE SCHEDULE .............................................................. 33

N

NO POWER AT THE AC RECEPTACLES............................................ 53

O

Oil Alert Indicator................................................................................ 17

OPERATION......................................................................................... 21

Operator Responsibility ....................................................................... 6

Output Indicator.................................................................................. 16

Q

QUICK REFERENCE INFORMATION........................ Inside back cover

R

Recoil Starter....................................................................................... 12

REFUELING ......................................................................................... 34

Refuel With Care................................................................................... 7

REGISTRATION................................................................................... 76

REMOVAL FROM STORAGE.............................................................. 50

79

Page 82: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

31Z037230.book 80 ページ 2016年9月8日 木曜日 午後8時45分

INDEX

S

SAFE OPERATING PRECAUTIONS.................................................... 21

SAFETY LABEL LOCATIONS................................................................ 8

Safety Precautions.............................................................................. 32

SEDIMENT CUP CLEANING............................................................... 41

Serial Number Location ..................................................................... 54

SERVICING YOUR GENERATOR ....................................................... 31

SPARK ARRESTER SERVICE.............................................................. 45

SPARK PLUG SERVICE....................................................................... 43

Special Requirements ........................................................................ 30

Specifications...................................................................................... 60

STANDBY POWER.............................................................................. 30

STARTING THE ENGINE .................................................................... 22

STOPPING THE ENGINE .................................................................... 24

STORAGE ............................................................................................ 46

STORAGE PRECAUTIONS ................................................................. 50

STORAGE PREPARATION.................................................................. 46

System Ground................................................................................... 30

T

TAKING CARE OF UNEXPECTED PROBLEMS ................................. 52

TECHNICAL INFORMATION............................................................... 54

THE IMPORTANCE OF MAINTENANCE............................................ 31

TRANSPORTING................................................................................. 51

W

Wiring Diagram................................................................................... 61

80

Page 83: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

QUICK REFERENCE INFORMATION

Fuel Type Regular unleaded gasoline with an

ethanol content of no more than

10% and a pump octane rating of

86 or higher

Engine Oil Type SAE 10W-30, API SJ or later (or

equivalent), for general use (see

page 38)

Spark Plug Type BPR6ES (NGK) W20EPR-U (DENSO)

Electrode Gap 0.028–0.031 in (0.7–0.8 mm)

Maintenance Before each use Check engine oil level. Check air filter. Check GFCI operation.

First 20 hours Change engine oil.

Subsequent See MAINTENANCE SCHEDULE (see page 33)

31Z037230.book 81 ページ 2016年9月8日 木曜日 午後8時45分

Page 84: GENERATOR EB3000ccdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z037230.pdf1 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased

C 2016 Honda Motor Co., Ltd. -All Rights Reserved

See page 74 for Initial Use Instructions

GENERATOR

BK PANTONE186C

EB3000c

31Z0372300X31-Z03-7230 Printed in Japan

FM

HiEM4 英AH

Owner’s Manual