Giám Sát Switch Bằng Phần Mềm PRTG

Embed Size (px)

Citation preview

Gim st switch bng phn mm PRTG Gim st my ch khc vi gim st lu lng ca switch hay router. Gim st lu lng l theo di tc , lu lng truyn nhn trn cc cng ca thit b, cn gim st my ch ngoi lu lng cng mng cn c cc thng s CPU, RAM, diskfree. PRTG l phn mm c th gim st cc thit b mng phn cng v cc server. Cch ci t v hng dn s dng y c th tm thy trn trang ch ca PRTG hoc trong rt nhiu ti liu khc trn internet. Trong ti liu ny tc gi ch hng dn mt s bc ti thiu bn c th gim st c mt server. Sau khi ci t PRTG Network Monitor, ta vo phn mm qua giao din web, ng nhp bng account v password mc nh prtgadmin, chuyn qua tab [Devices] v nhn link [+Add Device]. 5 Trang ch PRTG : http://www.paessler.com/prtg C2950#show snmp Chassis: FOC0833X23A Contact: Location: 0 SNMP packets input 0 Bad SNMP version errors 0 Unknown community name 0 Illegal operation for community name supplied 0 Encoding errors 0 Number of requested variables 0 Number of altered variables 0 Get-request PDUs 0 Get-next PDUs 0 Set-request PDUs 1 SNMP packets output 0 Too big errors (Maximum packet size 1500) 0 No such name errors 0 Bad values errors 0 General errors 0 Response PDUs 1 Trap PDUs SNMP global trap: enabled SNMP logging: enabled Logging to 192.168.1.100.162, 0/10, 1 sent, 0 dropped. SNMP agent enabled C2950#configure terminal C2950(config)#snmp-server enable C2950(config)#snmp-server enable traps C2950(config)#snmp-server community public ro C2950(config)#snmp-server community private rw C2950(config)#snmp-server host 192.168.1.100 version 1 public SNMP ton tp Chng 2 : Qun l mng vi SNMPD I P T H A N H N G U Y N , 2 0 1 0 T r a n g | 14 Nhp tn ca my ch cn gim st vo [Device Name], nhp IP ca my ch vo [Ip-Address/DNS Name], chn Automatic device identification (standard, recommended) PRTG t ng d tm thit b SNMP ang c to l g. Nhn nt Continue, PRTG s bt u tin trnh d tm. SNMP ton tp Chng 2 : Qun l mng vi SNMPD I P T H A N H N G U Y N , 2 0 1 0 T r a n g | 15Sau cc ti nguyn c th gim st c s hin ra mn hnh. hnh trn ta thy PRTG pht hin c 28 object c th gim st. Click vo tn thit b m ra mn hnh gim st, lit k danh sch cc port FastEthernet ca switch v bng thng ang s dng. Nh bn bit, SNMP manager ch ly c nhng thng tin m SNMP agent cung cp, do khng phi tt c mi th trn my ch u hin ra trn PRTG gim st. Nhiu bn khi cha hiu c ch ca SNMP cho rng PRTG khng gim st c mt ci g trn my ch l do nhc im ca PRTG v mong mun tm kim mt cng c khc hay hn. Thc cht nu agent trn thit b khng h tr thng tin th mi phn mm gim st u khng th ly thng tin . Kim tra hiu sut mng vi PRTG bn min phCp nht lc 10h36' ngy04/04/2009Bn in

David DavisQun tr mng Trong bi ny chng ti s gii thiu cho cc bn cch download, ci t, s dng b kim tra mng min ph PRTG kim tra v khc phc cc vn trong vic kt ni mng ca Windows.Gii thiuMt vi nm trc y bn c th s dng PRTG Traffic Grapher ca Paessler. PRTG Traffic Grapher l mt tin ch Windows n gin dng kim tra lu lng mng theo th c thu thp bng cch s dng SNMP, Netflow v cc phng php khc. Paessler cng cung cp mt phin bn PRTG khc c tn gi Network Monitor. y l phin bn khng cho php kim tra hiu sut v kt ni mng ni b cho my tnh ni b ca bn nhng kt ni v kim tra mng cho ton b doanh nghip. PRTG Network Monitor c th thc hin iu ny thng qua khong 10 kiu sensor khc nhau nh SNMP, WMI, & Netflow. Nu bn mun thy c PRTG Network Monitor c th gip bn kim tra my tnh Windows ni b v mng Windows nh th no, hy th s dng PRTG Network Monitor, version 7.PRTG l g, bn c th download t u v cch ci t nh th no?Paessler l mt cng ty ca c, sn phm chnh ca cng ty l PRTG. Nh c cp, c hai phin bn ca PRTG lNetwork MonitorvTraffic Grapher. C hai sn phm ny u c cc phin bn min ph v phin bn thng mi. Phin bn min ph b gii hn trong 10 sensor (cc phin bn thng mi cho dng th cng tng t). PRTG Network Monitor cho php bn thc hin cc hnh ng di y: Kim ta bng thng, hiu sut s dng, uptime v kh nng sn c Vn bo co v cnh bo Giao din webNetwork Monitor h tr vic kim tra cc mng ln n 30.000 sensor v c th bo co v tnh hnh cc kt ni c hi t SLA hay khng.Cc thit b Windows c th c kim tra bng SNMP, ping v WMI. Trong khi vi cc thit b non-Windows, bn c th kim tra chng bng vic sniffing (tm dch l kim tra) cc gi d liu, NetFlow (cho cc thit b Cisco), SMTP (cho cc my ch email), HTTP (cho cc my ch web) v mt s cng ngh kim tra khc.Bn hy download 27MB phn mm PRTG Networking Monitor min ph v bt u ci t ca mnh.

Hnh 1: Bt u ci t PRTGBn c th chn ci t Core Server hoc Remote Probe theo nh ca mnh.

Hnh 2: Chn ci t - Server hoc Remote ProbeTrong th nghim trong bi, chng ti chn s dng phin bn min ph.

Hnh 3: Ci t phin bn min ph (Free Edition)PRTG Network Monitor s ci t mt my ch web v c s d liu. Nh nhng g c th thy trong hnh 4, bn s cn phi chn username, password, a ch email qun tr ca mnh, giao din my ch PRTG web server s chy trn v s cng. Cng cn phi t tn cho my ch ca bn. Trong trng hp th nghim, chng ti chn giao din host ni b v s dng cng 81.

Hnh 4: Cc thit lp Network Monitor cn thitSau , PRTG s c ci t.S dng PRTG Network Monitorng nhp vo PRTG Network Monitor bng cch s dng trnh duyt web , nhp vo a ch IP v s cng c th trong qu trnh ci t.

Hnh 5: ng nhp PRTGTh u tin m bn cn thc hin l b sung thm cc thit b mng vo PRTG. Cch n gin nht thc hin iu l s dng tnh nngAuto Discovery.

Hnh 6: Chy AutoDiscoveryPRTG s tm ra cc thit b trn mng ca bn v bt u thu thp cc thng k v chng. Ph thuc vo kiu thit b, bn c th hoc khng th thc hin cc cng vic m rng cung cp cc chui SNMP mang tnh cng ng, Windows username & password cho WMI hoc cc tiu chun c th khc c c mt thng k chi tit hn.

Hnh 7Lu rng trong hnh 7 trn, 12 thit b mng khc nhau c pht hin mt cch t ng v c a vo PRTG. Thm ch khng c cu hnh, cc thit b khc cng ang c kim tra theo nhiu cch khc nhau, da vo cc kh nng ca chng. Cho v d, mt s thit b ch c kim tra bng cch s dng phng phpping. Cc thit b khc c kim tra bi phng phppingvhttp, nu chng c mt giao din web. Host ni b trong th nghim ca chng ti c kim tra bng cch s dngpingvdiskspace, memory, pagefile, processorvnetworking.Cui cng, HP printer th nghim cng c kim tra bngping, http,thm chsi c s trang inpages printed.PRTG Network Monitor c th gip bn gii quyt cc vn vi kt ni mng nh th no?y l 5 cch PRTG Network Monitor c th gip bn gii quyt c cc vn trong kt ni mng Windows:1. Kim tra CPU, b nh, trang nh v hiu sut mng ni b v t xaNh mt Windows Network Administrator, bn s thch kim tra tt c cc vn y, c ni b v t xa, v nu c mt vn no din ra trn mt thi th bn s phi gnh chu hiu sut h thng ni b ngho nn hoc hiu sut ngho nn trn ton b c s h tng Windows. Trong hnh 8 bn di, bn s thy hiu sut CPU cho my trm Vista ni b qua hai ngy (cho c hai li CPU). T y, chng ta c th kt lun trong trng hp ny, CPU th nghim khng gp phi hin tng nghn c chai khi s dng ti a l 62%.

Hnh 8: Hiu sut CPU cho h thng ni b th nghim sau hai ngy.Bn c th to cng kiu biu hin th % khng gian a, b nh, cn trng. Biu c th c hin th theo thi gian thc, trong vng 2 ngy, mt thng hoc thm ch trong khong thi gian 1 nm. Nh cp trong phn 4, chng ta c th cu hnh cc cnh bo da trn nhng chng ch g mnh chn.R rng, y l mt v d v h thng ni b trong th nghim, bn c th kim tra bt c h thng Windows no c th truy cp n, cng nh h thng non-Windows ( ging nh cc router Cisco, VMware servers,)2. Kim tra cc thng khc nh dung lng a trng, ccprocesses, services, hay cc bn ghi s kinNh nhng g th hin trong hnh 9 bn di, chng ta c th b sung thm cc kiu sensor khc. Trong th nghim, chng ti to mt vng trn mu khoanh vng quan trng vi cc qun tr vin mng. Chng l Windows Services, Processes, Files, Event Log Entries, v cc thnh phn d liu Windows sng cn khc.Bn cng c th kim tra cc kiu c s h tng ca mnh nh VMware ESX Servers, my ch web, my ch mail, cc thit b mng , SQL servers, my ch file v thm ch c cc my in.

Hnh 9: B sung thm kiu sensor khc3. Xem tt c cc thit b mng trn biu PRTG Network Monitor c th c s dng sp xp v phn loi cc thit b mng ca bn theo mt cch quan st no (hoc nhm). Nh vy, trong biu , bn s thy c cc bo cnh, ch s lu lng, ti ca CPU v thi gian p tr cho tt c cc thit b.

Hnh 10: Tt c cc thit b trong mng trn biu 4. c bo cnh bng email hoc SMSCu hnh cc cnh bo email v SMS vi nhiu kiu trigger khc nhau. Trong hnh 11, bn c th thy trng thi, tc , phn vng, ngng v thay i trigger thng bo.

Hnh 11: To cc Trigger thng bo5. Kim tra cc ng dng v cc my ch trn cc mng nhSMTP, HTTP, VMware,Thm vo , PRTG Network Monitor khng ch l mt cng c cho Windows m n cn l mt b kim tra mng c th phc v ton b cho c s h tng ca bn, h tr tt c cc kiu thit b.Nh cp trc, PRTG Network Monitor hin c cung cp di dng phin bn min ph v phin bn thng mi. V cui cng, mt l do na cho vic s dng PRTG Network Monitor l n c th kim tra kh nng tng thch ca iPhone (xem trong hnh 12).

Hnh 12: PRTG Network Monitor ang kim tra iPhoneKt lunTrong bi ny, chng ti gii thiu cho cc bn cch download, ci t v s dng tin ch min ph PRTG Network Monitor kim tra v khc phc s c cc vn kt ni mng trong Windows. Bn cnh PRTG c th gip bn khng ch kim tra c my tnh ni b v cn c cc my ch c s h tng v ton b mng ca bn.

Ci t cu hnh trn thit b gim st:Bn c th ci t chng trnh PRTG Traffic Grapher thc hin theo di lu lng trn cng ca thit b qua SNMP. PRTG Traffic Grapher l mt ng dng trn Windows theo di v phn loi cch dng bng thng.Sau khi thc hin ci t PRTG Traffic Grapher, bn cn kch hot ng dng PRTG Traffic Grapher.Hp thoi Welcome to PRTG Traffic Grapher s xut hin.Trn hp thoi Welcome to PRTG Traffic Grapher, la chn Use the Freeware Edition, sau nhn Next tip tc. S xut hin giao din chnh ca PRTG Traffic Grapher.

PRTG Traffic GrapherChn Click here to create your first sensor to cc sensor theo di.

To sensorSau , ChnNext tip tc

Add SensorPRTG Traffic Grapher c h tr cc loi: SNMP, Packet Sniffing, NetFlow, Latency. Phin bn min ph ch h tr SNMP v Packet Sniffing. SNMP c s dng theo di cc thng tin lu lng vo v ra ca cng trn router. Packet Sniffing c s dng theo di cc lu lng ca card mng ti my s dng. ChnSNMP (Simple Network Management Protocol)ri chnNext.

Chn SNMP monitor dataChnStandard Traffic Sensor.

Chn Standard Traffic SensorNhp cc thng s:- Device Name/Alias: Nhp tn router do bn t quy nh. C th chn IP ca thit b cho d nh.- IP Address/DNS Name: a ch IP ca router.- SNMP Version: Phin bn ca SNMP trn router h tr. Trong v d ny router h tr SNMP V1/V2 nn c th chn V2c.- SNMP port: gi tr ngm nh ca cng SNMP l 161.- SNMP Community String: Ngm nh l public. Gi tr ny cn ging vi gi tr trong phn cu hnh trn router.Nu s dng SNMP V3, cn phi xc nh SNMP User, Authentication Mode v Password, c thm la chn l Data Encryption key.

Nhp thng s router gatewayChn sensor cn c theo di ri chnNext.

Chn sensor cn theo diXc nh khong thi gian m thit b gim st s thc hin truy xut v xc nh Sensor c theo di, chnFinish.

Chn scanning intervalVic hin th c chia thnh cc loi biu h tr ngi qun tr theo di thun tin: Live Graph 60 Minutes, Graph 24 Hours, Graph 30 days, Graph 365 days vi cc mc thi gian v gi tr trung bnh khi hin th khc nhau. Bn cng c th xem thng tin trn trnh duyt web nu cn theo di thng tin t xa theo bng hoc theo th.

Theo di cng router gateway

Theo di cng router gateway Graph

Theo di cng router gateway Graph ttXem thng tin da theo bng d liu

PRTG thng tin bng d liuXem thng tin da theo th.

XHTTOnline:SNMP (Simple Network Management Protocol) l giao thc cho php kim tra cc thit b mng nh router, switch hay server ang vn hnh. Mt h thng s dng SNMP bao gm 2 thnh phn chnh: Manager v Agent. Agent l mt chng trnh chy trn thit b mng cn c qun l. Manager c chy t 1 my trong mng v c th truy vn n cc agent v x l thng tin nhn uc t agent. Trn phn ln cc router ADSL u c sn tnh nng SNMP . Khi xc lp tnh nng ny v vi mt chng trnh h tr SNMP trn Windows, ngi qun tr c th ly c cc thng tin do SNMP cung cp. PRTG Traffic Grapher l mt ng dng trn Windows theo di v phn loi cch dng bng thng. Vi cng c ny ngi qun tr mng c th theo di bng thng ca router ADSL thng qua giao thc SNMP. Trong khi cc chng trnh theo di bng thng da vo cc traffic thng qua cng card mng ca 1 my tnh trn mng th PRTG Traffic Grapher s theo di traffic trc tip ti cng PPP ca router ADSL nn theo di c ton b traffic IN, OUT ca ton mng. PRTG Traffic Grapher phin bn hin ti l 6.2.1.950/951 v c bn min ph, bn thng mi. Phin bn PRTG Traffic Grapher min ph (15MB) c download theo link sau:http://www.paessler.com/download/prtgBi vit ny s hng dn vic cu hnh SNMP trn router ADSL (loi Linksys) v s dng PRTG Traffic Grapher theo di bng thng.1. Xc lp SNMP trn router ADSL cu hnh router cung cp d liu SNMP, m trang web cu hnh router, tm tab Administration -> Management. Trong Management, tm mc SNMP (hnh di):

Enable SNMP trn Router ADSL

Trong mc SNPM, la chn Enable. Lu xem router ca bn h tr SNMP version no v gi tr Community. Trong v d ny, router h tr SNMP V1 v V2, gi tr Get Community l publicLu : Mc SNMP trong tab Administration -> Management v d trn l i vi 1 s router ca Linksys. Vi cc router loi khc, c th vic cu hnh SNMP tng t nh trn. Nu khng, bn cn phi xem ti liu hng dn s dng ca router .2. s dng PRTG Traffic Grapher theo di bng thngSau khi download PRTG Traffic Grapher, tin hnh ci t. Vic ci t thc hin kh d dng. chy chng trnh, trn Windows nhp Start -> Programs -> PRTG Traffic Grapher -> PRTG Traffic Grapher. Xut hin hp thoi Welcome to PRTG Traffic Grapher.

Hp thoi Welcome to PRTG Traffic Grapher

Trn hp thoi Welcome to PRTG Traffic Grapher, la chn Use the Freeware Edition, sau nhp Next tip tc. S xut hin giao din chnh ca PRTG Traffic Grapher.

Giao din PRTG Traffic Grapher

Trn giao din ca PRTG Traffic Grapher, nhp vo la chn Click here to create your first sensor to cc sensor theo di. Khi PRTG Traffic Grapher s chy cc bc cu hnh thm mt sensor mi. Di y l cc bc cu hnh chnh:

Add Sensor Wizard Data Acquisition Type

PRTG Traffic Grapher c h tr cc loi sensor: SNMP, Packet Sniffing, NetFlow, Latency. Phin bn min ph ch h tr SNMP v Packet Sniffing. SNMP sensor c s dng theo di cc traffic IN v OUT ca cng trn router. Packet Sniffing c s dng theo di cc traffic ca card mng ti my s dng. Trn hp thoi Data Acquisition Type, la chn SNMP.

Add Sensor Wizard SNMP Sensor Type Selection

Trn hp thoi SNMP Sensor Type Selection, la chn Standard Traffic Sensor. Cc la chn khc ty thuc vo thit b h tr SNMP.

Add Sensor Wizard Device Selection

Trn hp thoi Device Selection, xc nh cc gi tr: - Device Name/Alias: Nhp tn router do bn t quy nh. C th chn IP ca thit b cho d nh. - IP Address/DNS Name: a ch IP ca router. - SNMP Version: Phin bn ca SNMP trn router h tr. Trong v d ny router h tr SNMP V1/V2 nn c th chn V2c. C th chn ln lt tng phin bn th. - SNMP port: gi tr ngm nh ca cng SNMP l 161. - SNMP Community String: Ngm nh l public. Gi tr ny c th kim tra phn cu hnh SNMP trn router. Nu s dng SNMP V3, cn phi xc nh SNMP User, Authentication Mode v Password, c thm la chn l Data Encryption key.

Add Sensor Wizard Sensor Selection

Trn hp thoi Sensor Selection s xut hin cc cng m router h tr. La chn cng theo di ADSL l ppp0. Lu cc k hiu: ppp: Point-to-Point Protocol; eth: Ethernet; br: Bridge; wlan: Wireless. Sau khi la chn cng theo di, xut hin giao din ha theo di bng thng ca cng tng ng.

Sensor Monitoring

Vic hin th c chia thnh cc loi biu h tr ngi qun tr theo di thun tin: Live Graph 60 Minutes, Graph 24 Hours, Graph 30 days, Graph 365 days vi cc mc thi gian v gi tr trung bnh khi hin th khc nhau. Lu ng mu xanh l Bandwith Traffic OUT, ng mu nu l Bandwith Traffic IN. Trn y l mt tnh nng ca PRTG Traffic Grapher h tr ngi qun tr theo di bng thng ca router ADSL. Cc tnh nng khc, ngi c c th tham kho tr gip ca chng trnh.Centos5f4vn