C1 C2
C1 C2 C1 C2
C1 C2
LPJIS K2240 LPJIS K2240
1
5 10 15 20
2
3
45
6
7
8
25 30 35 40
1. Hydrogen2. Oxygen 3. Nitrogen4. Carbon Monoxide5. Methane6. Carbon Dioxide7. Ethylene8. Ethane
Column : SHINCARBON ST 50/80 mesh6.0m x 3.0mm I.D., SUS
Column temp : 40 (12min hold) 200 Program rate 10 /min
Injection temp : 200 Detector : TCD (200 )Carrier gas : He, 50 mL/minSample Volume: 0.5mL
1
5 10 15 20
2
3
4
56 7
8
25 30 35 40
1. Hydrogen2. Oxygen 3. Nitrogen4. Carbon Monoxide5. Methane6. Carbon Dioxide7. Ethylene8. Ethane
Column : SHINCARBON ST 50/80 mesh6.0m x 3.0mm I.D., Stainless
Column temp : 40 (12min hold) 200 Program rate 10 /min
Injection temp : 200 Detector : TCD (200 )Carrier gas : Ar, 50 mL/minSample Volume: 0.5mL
1
2 4 6 8
2
3
4
5 6
78
10 12 14
9
1. Oxygen2. Nitrogen 3. Carbon Monoxide4. Methane5. Carbon Dioxide
6. Nitrous Oxide7. Acetylene8. Ethylene9. Ethane
Column : SHINCARBON ST 50/80 mesh2.0m x 3.0mm I.D., SUS
Column temp : 40 (3min hold) 200 Program rate 20 /min
Injection temp : 200 Detector : TCD (210 )Carrier gas : He, 50 mL/min Sample Volume: 0.5mL
Column : SHINCARBON ST 50/80 mesh1.0m x 3.0mm I.D., SUS
Column temp : 40 300 Program rate 20 /minInjection temp : 300 Detector : TCD (300 )Carrier gas : He, 50 mL/minSample Volume: 0.75mL
1
25
2 3 4 5
6
7
8
9
10
11
5 10 15
30
20
1. Air2. Carbon Monoxide 3. Methane4. Carbon Dioxide5. Ethylene6. Ethane7. Propylene8. Propane9. iso-Butane
10. n-Butane11. n-Pentane
1
2
3 4
5 10 15
Column : SHINCARBON ST 50/80 mesh 6.0m x 3.0mm I.D., SUS
Column temp : 40 Injection temp : 50 Detector : TCD (50 )Carrier gas : Ar, 50 mL/minSample Volume: 1.0mL
1. Helium2. Hydrogen 3. Oxygen4. Nitrogen
1
2
3
10
1. Oxygen2. Nitrogen 3. Methane4. Carbon Monoxide
Column : Molecular Sieve 5A 60/80 mesh1.6m x 3.2mm I.D., Glass
Column temp : 50 Injection temp : 50 Detector : TCD (50 )Carrier gas : He, 40 mL/minSample Volume: 1.0mL
1Air, Methane 2Ethane, Ethylene 3Propane 4Propylene 5iso-Butane 6n-Butane 71-Butene, iso-Butene 8trans-2-Butene 9cis-2-Butene101,3-Butadiene11iso-Pentane12n-Pentane
Column6.0 33 m 3.0 mm I.D. Stainless steel Dibutyl Maleate-Oxydipropionitrile 955 35% Shinwasorb-U 40/60Column temp.40Carrier gasHe, 20 mL/minDetectorTCD
0 5 10 15 20 25 30 35 40
1
56
7
23
10 11 12
4
138 9 14
1. Air, Methane2. Ethane3. Ethylene4. Propane5. Propylene6. iso-Butane7. n-Butane
10.0 (5+5) m x 3.0 mmI.D.40TCDC1 C5 (5000ppm)
Dibutyl Maleate + Propylene Carbonate(35:65) 35% on Shinwasorb-U 40/60
Carrier gas 20ml/min HeHead Pressure 145 kPa
https://solutions.shimadzu.co.jp/glc 513
GC
07
GLC CATALOG 2017
1
2
3
45
6
7
8
9 1011
12 13
204 8 12
24
16
1
20
2
3
4
5
6
7 8
9
10
11
13
12
4 8 12
16
24 28
32
36
1
2
2
3
4
5
6
7
84 6
LP
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30
1
56
7
23
8 9 10 11 12 14
4
13
1. Air, Methane2. Ethane3. Ethylene4. Propane5. Propylene6. iso-Butane7. n-Butane
9.0 (3+3+3) m x 3.0 mmI.D.40TCD C2 C5 (5000ppm)
Sebaconitrile 25%on Shinwasorb-U 40/60
Carrier gas 22ml/min HeHead Pressure 180 kPa
1. Air2. Methane 3. Carbon Dioxide4. Nitrous Oxide5. Ethylene6. Ethane7. Water
Column : Sunpak-A 50/80 mesh 2.1m x 3.2mm I.D., GlassColumn temp : 40 Injection temp : 200 Detector : TCD (150 )Carrier gas : He, 40 mL/minSample Volume: 1.0mL
1. Methane2. Ethylene 3. Ethane4. Propylene5. Propane6. iso-Butane7. n-Butane8. n-Pentane9. n-Hexane
10. n-Heptane11. n-Octane12. n-Nonane13. n-Decane
Column : Sunpak-A 50/80 mesh 2.1m x 3.2mm I.D., GlassColumn temp : 65 250 Program rate 10 /minInjection temp : 260 Detector : FID (260 )Carrier gas : N2, 50 mL/minSample Volume: 0.5mL
1. Methane2. Ethane, Ethylene 3. Propane4. Propylene5. iso-Butane6. Cyclopropane7. n-Butane8. 1-Butene, iso-Butene9. trans-2-Butene
10. cis-2-Butene11. iso-Pentane12. 1,3-Butadiene13. n-Pentane
Column : SM-6 6.0m(3m+3m) x 3.0mm I.D., SUSColumn temp : 30 Injection temp : 50 Detector : FID (50 )Carrier gas : N2, 20 mL/minSample Volume: 1.0mL
Column3.0 m 2.2 mm I.D. Stainless steelSilicone DC-200 20% Shinwasorb-U 40-60Column temp.50 1 min 10/min 120Injection port temp.200DetectorFID 200Carrier gasHe, 15 mL/minSample volume0.1 mL gas
1Methane 2Ethane 3Propane 4Isobutane 5n-Butane 6Isopentane 7n-Pentane 8Isohexane 93-Methylpentane10n-Hexane
Column3.0 m 2.2 mm I.D. Stainless steelTCEP 10% Shinwasorb-U 40-60Column temp.80Injection port temp.200DetectorFID 200Carrier gasHe, 20 mL/minSample volume0.1 uL
1Benzene2Toluene3Ethylbenzene4p-, m-Xylene5o-Xylene61,2,4-Trimethylbenzene
12 3
45 6
87
910
11
1213
0 10 20 30 40
1. n-C102. n-C113. n-C124. n-C135. n-C146. n-C157. n-C168. n-C179. n-C18
10. n-C1911. n-C2012. n-C2113. n-C22
Column: 2.5 m x 3.0 mm I.D. StainlessSample: Mixture of kerosene and light oil Sample volume: 1.0 LColumn temp.: 80-250 (6 /min), 250 (12 min hold) Carrier gas: 50 mL/min N2Injection port temp.: 270 Detector: FID 270
Silicone SE- 52 5% Shinwasorb -U 40/60
514 Shimadzu GLC Ltd.
GC
07
GLC CATALOG 2017
1
2
3
4
56
7
8
0 5 10 15
Column: 2.1 m x 3.2 mm I.D. GlassSample: DMFColumn temp.: 110Injection port temp.: 230
Detector: FID 230Sample volume: 1 LCarrier gas: 50 mL/min N2
1. Benzene2. Toluene3. Ethylbenzene4. Isopropylbenzene5. n-Propylbenzene6. Styrene monomer7. Cyclopentanol8. N,N-Dimethylformamide
FON 10% Shinwasorb-S 60/80*
* Original stationary phases manufactured by Shinwa Chemical Industries Ltd.
Shinchrom F51 + Bentone34 3 + 2% Shinwasorb-U 60/80*1
2
4
5
3
0 5 10 15
1. Hexane2. Ethylbenzene3. p-Xylene4. m-Xylene5. o-Xylene
Column: 2.1 m x 3.2 mm I.D. GlassSample: 100 ppm in hexaneColumn temp.: 80Injection port temp.: 240
Detector: FID 240Sample volume: 1 LCarrier gas: 40 mL/min N2
* Original stationary phases manufactured by Shinwa Chemical Industries Ltd.
Column 3.0 m 2.2 mm I.D. Stainless steel TCEP 10% Shinwasorb-U 40-60Column temp. 80Injection port temp. 200Detector FID 200Carrier gas He, 20 mL/minSample volume 0.1 uL
1n-Octane 2n-Nonane 3n-Decane 4n-Undecane 5Benzene 6n-Dodecane 7Toluene 8p-Xylene 9o-Xylene101,2,4-Trimethylbenzene
Column 3.1 m 3.2 mm I.D. Glass Polyethylene glycol 1500 20% Shinwasorb-S 40-60Column temp.100
1Acetone2Ethyl acetate3Methyl ethyl ketone4Methanol
Injection port temp. 200Detector FID 200Carrier gas Nitrogen, 50 mL/minSample volume 0.1 uL
52-Propanol6Toluene7n-Butyl acetate
0 10 20 30
2
3
6
5
7
8
9
10
11
12
14
13
15
16
17
18
1
4
Column: 2.1 m x 3.2 mm I.D. Glass
Sample volume: 1.0 L
Sample: 22
Column temp.: 60120 (4 /min)
Carrier gas: 40 mL/min N2
Detector: FID 200
Injection port temp.: 200
1. Methylcyclohexane2. Acetone3. Ethyl acetate4. Methyl ethyl ketone5. Methanol6. iso -Propanol7. Ethanol, n-propylacetate8. n-Propanol, iso-butyl acetate,
methyl isobutyl ketone9. Toluene
10. n-Butyl acetate11. Ethylbenzene12. m,p-Xylene13. o-Xylene , propyleneglycol
monomethyl ether14. Styrene15. Ethyl cellosolve16. Cellosolve acetate17. Cyclohexanone18. Diacetone alcohol
PEG1500 12.5% Shinwasorb-U 40/60
1
2
345
67
8
9
10
11
12 13
14
15
16
17
18
150 5 2520
10
30
1. n-Hexane2. Methanol3. Acetone4. 2-Propanol 5. Ethyl Acetate6. Methyl Ethyl Ketone7. Benzene8. Trichloroethylene9. Isobutanol
10. Isobutyl Acetate11. Toluene12. n-Butyl Acetate13. Isoamyl Alcohol14. Ethylbenzene15. m,p-Xylene16. o-Xylene17. n-Propylbenzene18. Cyclohexanone
Column : SBS-100 10% Shimalite TPA 60/80 mesh 3.1m x 3.2mm I.D., GlassColumn temp : 110 Injection temp : 200 Detector : FID (200 )Carrier gas : N2, 30 mL/minSample Volume: 1.0 mL
12
3
4
5
6
7
8 910
11 1213
14
15
1617
82 4 12
106 14
18
16 26
24
22
20
1. Diethyl Ether2. n-Hexane3. Methanol4. Methyl Acetate 5. 2-Propanol6. Ethyl Acetate7. Tetrahydrofuran8. 2-Butanol9. Isobutanol
10. Toluene11. n-Butyl Acetate12. Methyl n-Buthyl Ketone13. Isoamyl Alcohol14. Ethylbenzene15. m,p-Xylene16. o-Xylene17. Styrene
Column : SBS-120 12% SHINCARBON A 80/100 mesh 3.1m x 3.2mm I.D., GlassColumn temp : 100 Injection temp : 200 Detector : FID (200 )Carrier gas : N2, 30 mL/minSample Volume: 1.0 mL
https://solutions.shimadzu.co.jp/glc 515
GC
07
GLC CATALOG 2017
12
3
4
5
6
7
8
205 10
25
15
9
10
11
12
13
14
15
1716 18
Column : SBS-200 20% Shimalite W 100/120 mesh AW -DMCS, 3.1m x 3.2mm I.D., GlassColumn temp : 100 Injection temp : 240 Detector : FID (240 )Carrier gas : N 2 , 50 mL/minSample Volume: 1.0 mL
1. Acetone2. 2-Propanol3. n-Hexane4. Ethyl Acetate 5. Chloroform6. Carbon Tetrachloride7. n-Butyl Alcohol8. Methyl Isobutyl Ketone9. Isobutyl Acetate
10. Toluene11. n-Butyl Acetate12. Ethylbenzene13. m,p-Xylene14. o-Xylene15. Cyclohexanone16. Buthyl Cellosolve17. 1,1,2,2-Tetrachloroethane18. o-Dichlorobenzene
1
2
3
4
5
6
7 8
205 10
15
9
10
1112
1. Dichloromethane2. trans-1,2-Dichloroethylene3. Chloroform4. 1,2-Dichloroethane 5. 1,1,1-Trichloroethane6. Carbon Tetrachloride
7. Trichloroethylene8. Toluene9. Tetrachloroethylene
10. Chlorobenzene11. 1,1,2,2-Tetrachloroethane12. o-Dichlorobenzene
Column : SBS-300 20% Shimalite W 80/100 mesh AW-DMCS, 3.1m x 3.2mm I.D., GlassColumn temp : 100 Injection temp : 240 Detector : FID (240 )Carrier gas : N2, 30 mL/minSample Volume: 1.0 mL
1
2
3
4
5 6
2 12
78
9
10
64 8 10
Column : Thermon-1000 5% Sunpak-A 50/80 mesh2.1m x 3.2mm I.D., Glass
Column temp : 180 Injection temp : 240
Detector : FID (240 )Carrier gas : N2, 50 mL/minSample Volume: 1.0L
1. Water2. Methanol3. Acetaldehyde4. Ethanol5. 2-Propanol6. 1-Propanol7. Ethyl Acetate8. Isobutanol9. n -Butanol
10. Isoamyl Alcohol
1
2
34
5
2 4 61. Water2. Ethanol3. Acetonitrile4. 2-Propanol5. Hexane
Column : Thermon-1000 5% Sunpak-A 50/80 mesh 2.1m x 3.2mm I.D., Glass
Column temp : 180
Injection temp : 250 Detector : FID (230 )Carrier gas : N2, 50 mL/minSample Volume: 1.0L
1
2
3
4
5
6
28
204 8 12 24
16 32
1. 2-Propanol2. Methyl Cellosolve3. n -Butanol4. 1-Methoxy -2-Propanol5. Ethyl Cellosolve6. Buthyl Cellosolve
Column : Thermon-1000 5% Sunpak-A 50/80 mesh 2.1m x 3.2mm I.D., Glass
Column temp : 170 220 Program rate 6 /minInjection temp : 260 Detector : FID (260 )Carrier gas : N2, 50 mL/minSample Volume: 1.0L
1
2,34
56
78
0 1 2 3 4 5 6 7 8 9 10
PEG 20M 5% Shinwasorb-S 60/80
Column: 2.1 m x 3.2 mm I.D. GlassColumn temp.: 90Injection port temp.: 250Detector temp.: 250 FIDSample volume: 1 LCarrier gas: 50 mL/min N2
1. Acetone (solvent)2. sec-Butanol3. n-Propanol4. iso-Butanol5. Allyl alcohol6. n-Butanol7. iso-Amyl alcohol8. n-Amyl alcohol
(1,000 ppm v/v)
0 10
1
23
4
5
6
87
Column: 2.1 m x 3.2 mm I.D. GlassSample: Low Alcohol in waterCarrier gas: 50 mL/min N2Injection port temp.: 250Sample volume: 1.0 LColumn temp.: 150Detector: 250FID)
1. Methanol2. Ethanol3. 2-Propanol4. 1-Propanol5. iso-Butane6. n-Butane7. iso-Amyl alcohol8. n-Amyl alcohol
Sunpak-H 60-80
516 Shimadzu GLC Ltd.
GC
07
GLC CATALOG 2017
Diol
0 1 0 2 0
1 2
3
4
5
68
7
1. Methanol2. Acetaldehyde3. Ethanol4. Acetic acid5. n-Propanol6. Ethyl acetate7. iso-Butanol8. Active amyl alcohol
iso-amyl alcohol
Column: 2.1m x 3.2 mm I.D. GlassSample: Carrier gas: 20 mL/minN2Injection port temp.: 230Sample volume: 1.0 LColumn temp.: 150Detector: 230FID)
1
23
4
5 6
7
8
9
10
2 1264 8 10
14
16
18
1. Air2. Formaldehyde3. Acetaldehyde4. Methyl Formate5. Acetone6. Methanol7. Ethanol, 2 -Propanol8. Water, 1 -Propanol9. Acetic Acid
10. Formic Acid
Column : TSG-1 15% SHINCARBON-A 60/80 mesh 3.1m x 3.2mm I.D., Glass
Column temp : 60 180 Program rate 8 /minInjection temp : 200 Detector : TCD (200 )Carrier gas : He, 40 mL/minSample Volume: 1.0L
Sunpak-H 60-80
0 10 20 30
1
2
34
5
6
87
Sunpak-H 60-80 Sunpak-H 60-801. AcetoneAcetonitrile2-Propanol2. Dichloromethane3. MetyletylketoneMEK4. TetrahydrofuranTHF5. 1,4-Dioxane6. N,N-dimethylformamide7. DimethylsulfoxideDMSO8. Cyclohexanone
Column: 2.1 m x 3.2 mm I.D. GlassSample: in waterCarrier gas: 50 mL/min N2Injection port temp.: 250
Sample volume: 1.0 LColumn temp.: 165Detector: 250FID)
1. Ethylene glycol2. 1,2-Propanediol3. 1,3-Propanediol4. 1,3-Butanediol5. 1,4-Butanediol6. Diethylene glycolGlycerol
0 5 10 15 20
12
34
5
6
Column: 2.1 m x 3.2 mm I.D. GlassSample: Diol in waterCarrier gas: 50 mL/min N2Injection port temp.: 250
Sample volume: 1.0 LColumn temp.: 190Detector: 250FID)
1
2
204 8 12
16 24
Column : Sorbitol 12% Chromosorb W 80/100 mesh NAW 1.5m x 3.0mm I.D., Stainless
Column temp : 150 Injection temp : 230 Detector : FID (230 )Carrier gas : N2, 60 mL/minSample Volume: 1.0L
1. Ethyleneglycol2. Diethyleneglycol
1 2
3
4
5
6
5
Column : FAL-M 10% Shimalite TPA 60/80 mesh, 2.1m x 3.2mm I.D., Glass
Column temp : 75 Injection temp : 240 Detector : FID (240 )Carrier gas : N2, 40 mL/minSample Volume: 1.0L
1. Acetaldehyde2. Propionaldehyde3. Isobutylaldehyde4. n-Butylaldehyde5. Isovaleraldehyde6.n-Valeraldehyde
1
2
10
3
4
5
6 1. Acetaldehyde2. Acrolein3. Crotonaldehyde4. Paraldehyde5. Furfural6. Benzaldehyde
Column : FAL-M 10% Shimalite TPA 80/100 mesh NAW 1.5m x 3.0mm I.D., SUS
Column temp : 150 Injection temp : 230 Detector : FID (230 )Carrier gas : N2, 60 mL/minSample Volume: 1.0L
https://solutions.shimadzu.co.jp/glc 517
GC
07
GLC CATALOG 2017
1
23
4
5
6
724204 8 12
16
Column : FFAP + H3PO4 0.3+0.3% Graphitecarbon 60/80 mesh 1.6m x 3.2mm I.D., Glass
Column temp : 80 220 Program rate 16 /minInjection temp : 260 Detector : FID (260 )Carrier gas : N2, 60 mL/minSample Volume: 1.0L
1. Acetic Acid2. Propionic Acid3. iso -Butyric Acid4. n -Butyric Acid5. iso -Valeric Acid6. -Valeric Acid7. n -Heptanoic Acid
1
2
3 45 6
78
9
10
204 8 12 16
24
1. Acetic Acid2. Propionic Acid3. iso -Butyric Acid4. n -Butyric Acid5. iso -Valeric Acid6. n -Valeric Acid7. iso -Caproic Acid8. n -Caproic Acid9. n -Heptanoic Acid
10. Lactic Acid
Column : Thermon-3000 5% SHINCARBON-A 60/80 mesh 1.6m x 3.2mm I.D., Glass
Column temp : 80 220 Program rate 6 /minInjection temp : 260 Detector : FID (260 )Carrier gas : N2, 50 mL/minSample Volume: 1.0L
1 2 3
4
5
6
87
9
4 8 12 16
1. Acetic Acid2. Propionic Acid3. iso -Butyric Acid4. n-Butyric Acid5. iso -Valeric Acid6. n-Valeric Acid7. iso -Caproic Acid8. n-Caproic Acid9. n-Heptanoic Acid
Column : FAL-M 10% SHINCARBON-A 80/100 mesh 2.1m x 3.2mm I.D., Glass
Column temp : 150 Injection temp : 260 Detector : FID (260 )Carrier gas : N2, 40 mL/minSample Volume: 1.0L
12
3
4
56
7 8
0 10 20
Column: 2.1 m x 3.2 mm I.D. GlassSample: Lower free fatty acid in water (2000 ppm)Carrier gas: 50 mL/min N2Injection port temp.: 250
Sample volume: 1.0 LColumn temp.: 175Detector: 250 (FID)
1. Acetic acid2. Propionic acid3. iso-butyric acid4. n-butyric acid5. iso-valeric acid6. n-valeric avid7. iso-caproic acid8. n-caproic acid
Sunpak-H 60/80 Column3.0 m 3.0 mm I.D. Glass *FON 20% Shinwasorb-U 40-60Column temp.200Injection port temp.250DetectorFID 250Carrier gasHelium, 20 mL/minSample volume1 uL
1Acetone solvent 2Acetic acid 3Propanoic acid 4Isobutyric acid 5n-Butyric acid 6Isovaleric acid 7n-Valeric acid 8Isocapric Acid 9n-Capric acid10n-Enanthic acidEach 100 ppm w/v
Column: 2.1 m x 3.2 mm I.D. GlassSample: Column temp.: 150Injection port temp.: 250
Detector: FID 240Sample volume: 1 LCarrier gas: 50 mL/min N2
1
2
4
5
3
9
67
8
10
0 5 10 15
1. Acetone2. Acetic acid3. Propionic acid4. Isobutyric acid5. Butyric acid6. Isovaleric acid7. Valeric acid8. Isocaproic acid9. Capric acid
10. Enanthic acid
Thermon-1000 + H3PO4 2.5 + 0.25% Shinwasorb-U 60/80
*
0 5 10 15 20 25
54
6
1 32
7
8
9
1011
min
5% Shinchrom E71 Shinwasorb-U 60/80
Column: 3.1 m x 3.2 mm I.D. GlassSample: FAME (C10C24)Carrier gas: 40 mL/min N2Injection port temp.: 250
Sample volume: 1.0 LColumn temp.: 230Detector: FID 250
1. Acetone2. C103. C124. C145. C166. C187. C18=18. C209. C22
10. C22=111. C24
518 Shimadzu GLC Ltd.
GC
07
GLC CATALOG 2017
-
1 2
3
4
5
67
8
9
5 10
10
Column : Advance-DS 5% Chromosorb W 80/100 mesh AW-DMCS, 2.1m x 3.2mm I.D., Glass
Column temp : 200 Injection temp : 260 Detector : FID (260 )Carrier gas : N2, 40 mL/minSample Volume: 1.0L
1. Methyl Caprate2. Methyl Laurate3. Methyl Myristate4. Methyl Palmitate5. Methyl Stearate6. Methyl Oleate7. Methyl Linoleate8. Methyl Arachidate9. Methyl Linolenate
10. Methyl Behenate
1 2 3
4
5
6 7
8
910
204 8 12
16
24
28
32
36
Column : Shinchrom E71 5% Shimalite-TPA 60/80 mesh 3.1m x 3.2mm I.D., Glass
Column temp : 90 180 Program rate 5 /minInjection temp : 260 Detector : FID (260 )Carrier gas : N2, 60 mL/minSample Volume: 1.0L
1. Methyl Myristate2. Methyl Palmitate3. Methyl Palmitoleate4. Methyl Stearate5. Methyl Oleate6. Methyl Linoleate7. Methyl -Linolenate8. Methyl cis-5,8,11,14,17
-Eicosapentaenoate9. Methyl cis-7,10,13,16,19
-Docosapentaenoate10. Methyl cis-4,7,10,13,16,19
-Docosahexaenoate
1Trimethylamine2Dimethylamine3Methylamine4Ethanol solvent Each 100 ppm w/v
Column3.1 m 3.2 mm I.D. GlassDiglycerolTEPKOH 7.57.51%Shinwasorb-S 60-80Column temp.70
Injection port temp.200DetectorFID 200Carrier gasNitrogen, 50 mL/minSample volume1 uL
23
4
56
1. Monomethylamine (1,000 ppm)
2. Dimethylamine (500 ppm)
3. Ethylamine (500 ppm)
4. Trimethylamine (1,000 ppm)
5. Triethylamine (500 ppm)
6. Monoethanolamine (2,000 ppm)
Column: Thermon-3000 + KOH 2+2%Sunpak-N 60/100 mesh 2.1 m x 3.2 mm I.D.
Column temp.: 120 (5 min hold) 200
Program rate: 4/minCarrier gas: N2 50 mL/minInjection: 1 mL (250)Detector: FID (250)
1
2
3
4
164 8 12
5 6
1. Air, Methane2. Ethane 3. Ammonia4. Propane5. iso-Butane, Monomethylamine6. n-Butane
Column : Thermon-3000 + KOH 2+2% Sunpak-N 60/100 mesh 2.1m x 3.2mm I.D., Glass
Column temp : 80 Injection temp : 100 Detector : TCD (100 )Carrier gas : He, 50 mL/minSample Volume: 1.0L
0 10 20
12
4
3
5
67
1. Chloroform2. 1,1,1-Trichloroethane3. Trichloroethylene4. Bromodichloromethane5. Tetrachloroethylene6. Chlorodibromomethane7. Bromoform
Silicone DC-550 10% Shinwasorb-S 60/80
Column: 3.1 m x 3.2 mm I.D. GlassSample: Standard mixture of trihalomethanes Column temp.: 90Injection port temp.: 220Detector: ECD 220Sample volume: 1 LCarrier gas: 50 mL/min N2
Column: 3.1 m x 3.2 mm I.D. GlassSample: Chlorinated solvents in airColumn temp.: 100Injection port temp.: 240
Detector: FID 240Sample volume: 1 mLCarrier gas: 30 mL/min N2
*SBS-300 10% Shinwasorb-S 60/80
* Original stationary phases manufactured by Shinwa Chemical Industries Ltd.
1. Dichloromethane2. trans-1,2-Dichloroethylene3. Chloroform4. 1,2-Dichloroethane5. 1,1,1-Trichloroethane6. Carbon tetrachloride7. Trichloroethylene8. Toluene9. Tetrachloroethylene
10. Chlorobenzene11. 1,1,2,2,-Tetrachloroethane12. o-Dichlorobenzene
1 2 3
4
65 7 8
10
911
4 20
8 12
16
Column : SHINCARBON-ST 50/80 mesh,1.0m x 3.0mm I.D., Glass
Column temp : 170 270 Program rate: 8 Injection : 280
Detector : FID (280 )Carrier gas : N2, 50 mL/minSample Volume: 0.25L
1. Methane2. Acetylene 3. Ethylene4. Ethane5. Chloromethane6. Propylene7. Propane8. Vinylchloride9. Dichloromethane
10. iso-Butane11. n-Butane
https://solutions.shimadzu.co.jp/glc 519
GC
07
GLC CATALOG 2017
PCB
PCBs
PCBs
Column3.1 m 3.2 mm I.D. Glass12.5 % , -Oxydipropionitrile Shinwasorb-S 60/80 STSampleEach 1.0 ppm in benzeneSample volume1.0 LCarrier gas50 mL/min N2Column temp.70Injection port temp.180DetectorFPD S 180
1Carbonyl sulfide2Hydrogen sulfide3Carbon disulfide4Methyl mercaptan5Ethyl mercaptan6Dimethyl sulfide7Dimethyl disulfide
12
4
5 6 7
3
0 5 10 15 20
Column: 3.1 m x 3.2 mm I.D. GlassSample: Each 1.0 ppm in Benzene Column temp.: 70Injection port temp.: 180Detector: FPD 180Sample volume: 1 LCarrier gas: 50 mL/min N2
1. Carbon sulfide2. Hydrogen sulfide3. Carbon disulfide4. Methyl mercaptan5. Ethyl mercaptane6. Dimethyl sulfide7. Benzene
1,2,3-TCEP 25% Shinwasorb-S 80/100 ST 1
2
3 4
2 4 6
5
8 10
12
16
14
6 8
7
Column : Sunpak-S 80/100 mesh, 2.1m x 3.2mm I.D., GlassColumn temp : 100 Injection temp : 180 Detector : FPD (180 )Carrier gas : N2, 50 mL/minSample Volume: 1.0mL
1. Methane2. Ethane 3. Hydrogen Sulfide4. Carbonyl Sulfide5. Propane, Propylene6. Iso-Butane7. Methyl Mercaptan8. n-Butane
1
2
0 1 2 3 4
Thermon-HG 5% Shinwasorb-U 60/80*
1. Methyl mercuric chloride2. Ethyl mercuric chloride
(100 ppb in n-hexane)
Column: 0.5 m x 3.0 mm I.D. GlassColumn temp.: 160Injection port temp.: 250
Detector: ECD 250Sample volume: 1 LCarrier gas: 50 mL/min N2
* Original stationary phases manufactured by Shinwa Chemical Industries Ltd.
0
24
25
26 27
14
1516
17
18
19
20
2122
23
13
20 40 60 80
4
1
5
78
11
12
10
3
92
0
6
Silicone OV-17 2 Shinwasorb-S 60/80
Column: 2.1 m x 3.2 mm I.D. GlassSample: KC-mix each 1.0 ppm in hexaneColumn temp.: 210Injection port temp.: 260Detector: ECD 260Sample volume: 4 LCarrier gas: 50 mL/min N2
0 20 40 60
16
17
18
19
20
21
2223
2425
26
0
14
15
4
1
5 67 8
2 1112
1310
3
9
Column: 2.1 m x 3.2 mm I.D. GlassSamp le: KC-mix each 1.0 ppm in hexane Carrier gas: 50 mL/min N2Injection port temp.: 260
Samp le volume: 4.0 LColumn temp.: 195Detector: ECD 260
2 Silicone OV-1 Shinwasorb-S 60/80 N2:50ml/min Column2.1 m 3.2 mm I.D. Glass1% Silicone OV-17 Shinwasorb-U 60/80SampleOrganophosphorus compoundsSample volume1 LCarrier gas50 mL/min N2Column temp.180-250 8/min)Injection port temp.260DetectorFPD 260
1Acetone2Dichlorvos DDVP3Methyldemeton4Methyl parathion5Parathion6EPN
520 Shimadzu GLC Ltd.
GC
07
GLC CATALOG 2017
1
2
3
0 5 10 15
Sunpak-A 50/80
1. Methanol2. Propyleneglycol3. 1,3-PropanediolTrimethyleneglycol)
Column: 2.1 m x 3.2 mm I.D. GlassSample: Propyleneglycol, 1,3-propanediolCarrier gas: 50 mL/min N2
Sample volume: 1.0 LColumn temp.: 180Detector: FID 230
Injection port temp.: 200
1
43
2
5
0 5 10 15
1. Acetone2. Sorbic acid3. Dehydroacetic acid4. Benzoic acid5. trans-Stilbene
Column: 3.1 m x 3.2 mm I.D. GlassSample: PreservativesColumn temp.: 200Injection port temp.: 260
Detector: FID 260Sample volume: 1 LCarrier gas: 50 mL/min N2
* Original stationary phases manufactured by Shinwa Chemical Industries Ltd.
*Advance-DS + H3PO4 2 + 0.25% Shinwasorb-S 60/80
FAP-S Shinwasorb-U 60/80
1. Acetone2. 2,6-Xylenol3. o-Cresol4. Phenol5. 2,4-Xylenol6. p-Cresol7. m-Cresol8. 3,5-Xylenol9. 3,4-Xylenol
Column: 3.1 m x 3.2 mm I.D. GlassColumn temp.: 160Injection port temp.: 250
Detector: FID 250Sample volume: 1 LCarrier gas: 50 mL/min N2
1
2
45
3
67
8 9
0 10 20 30 40
*
* Original stationary phases manufactured by Shinwa Chemical Industries Ltd.
Column2.1 m 3.2 mm I.D. Glass12.5% Flexol 8N8 Shinwasorb-U 60/80SampleEthylene oxideSample volume100 LCarrier gas40 mL/min N2Column temp.50Injection port temp.150DetectorFID 150
1Ethylene oxide2Propylene oxide
1
2 3 4 56 78
910
11
12
13
14
15
2716
18
19
202123
22
2425
2628
17
0 10 20 30 40
Thermon-3000 5% Shinwasorb-S 80/100 *
1. Hexane2. -Pinene3. -Pinene4. Limonene5. n-Octyl aldehyde6. n-Nonyl aldehyde7. Citronellal8. n-Decyl aldehyde9. Linalool
10. Linalyl acetate
11. Isobornyl acetate (citronellol)12. Menthol13. Benzyl acetate14. Perillaldehyde15. Geraniol16. -Ionone17. Benzyl alcohol18. Rose-P19. n-Dodecyl alcohol20. Anisaldehyde
21. Methyl cinnamate22. Ethyl cinnamate23. Eugenol24. Heliotropin25. Diethyl phthalate26. Vanillin27. Benzyl benzoate28. Benzyl salicylate
Column: 2.1 m x 3.2 mm I.D. GlassSample: Column temp.: 80-2606 /min)Injection port temp.: 280Detector: FID 280Sample volume: 1 LCarrier gas: 50 mL/min N2* Original stationary phases manufactured by Shinwa Chemical Industries Ltd.
2
3
41
0 5 10 15 20
1. Ethyl acetate2. di-n-butyl phthalate3. Teprenone (mono-cis isomer)4. Teprenone (all-trans isomer)The resolution between the mono-cis andall trance-isomers of teprenone: 1.69
FFAP 5% Shinwasorb-U 80/100
Column: 2.1 m x 3.2 mm I.D. GlassSample: TeprenoneColumn temp.: 235Injection port temp.: 270
Sample volume: 2.0 LCarrier gas: 47 mL/min N2Detector: FID 270
2
3
4
1
0 5 10 15 20
1. Ethyl acetate2. di-n-butyl phthalate3. Teprenone (mono-cis isomer)4. Teprenone (all-trans isomer): 1.63
FON 5% Shinwasorb-U 80/100*
Column: 2.1 m x 3.2 mm I.D. GlassSample: TeprenoneColumn temp.: 235Injection port temp.: 270Detector temp.: FID 270Sample volume: 2 LCarrier gas: 47 mL/min N2
* Original stationary phases manufactured by Shinwa Chemical Industries Ltd.* Conform to Japanese Pharmacopeia
https://solutions.shimadzu.co.jp/glc 521
GC
07
GLC CATALOG 2017
d- , dl-
* Original stationary phases manufactured by Shinwa Chemical Industries Ltd.
Column: 5.1 m x 3.2 mm I.D. GlassSample: 200 ppm in hexaneColumn temp.: 120 /130Injection port temp.: 200Detector temp.: 200 FIDSample volume: 2 LCarrier gas: 40 mL/min N2
0 10 20 30
12
3
0 10 20 30
12
3
1. Limonene2. Cineole
121.81(1.5)
3. Anisole
Thermon-3000 5% Shinwasorb-S 80/100 Column temp.: 130*
Thermon-3000 5% Shinwasorb-S 80/100 Column temp.: 120*
1. Limonene2. Cineole
121.98(1.5)
3. Anisole
Apiezone L + KOH 2+1% Shinwasorb-S 80/100
Column: 2.1 m x 3.2 mm I.D. GlassSample: Column temp.: 125 (5 min hold) 150 (5 /min)
150 (10 min holdInjection port temp.: 200Detector: FID 200Sample volume: 2 LCarrier gas: 50 mL/min N2
1. Chloroform2. Ethanol3. Naphthalene4. Amantadine
1
2
3
4
0 5 10 15 20
Silicone SE-52 2.5% Shinwasorb-S 80/100
2
3
1
0 2 4 6 8 10 12
1. N,N-dimethylformamide
2. Triphenylantimony
3. Spectinomycin
5
2
Column: 0.6 m x 3.2 mm I.D. Glass
Sample volume: 1.0 LDetector: FID 220
Sample: N,N-dimethylformamide, Triphenylantimony, SpectinomycinColumn temp.: 180Injection port temp.: 215Carrier gas: 37 mL/min N (Adjust so that the retention time of spectinomycin is about 10 minutes.)
DEGS 1.5% Shinwasorb-S 60/80
1
3
2
0 5 10 15
1. Ethyl acetate2. Caf feine3. o-Toluene sulfonamide
4.4
o-2
Column: 1.0 m x 3.0 mm I.D. Glass Sample volume: 1.0 LSample: Ethyl acetate, Caffeine, o-Toluene sulfonamide Detector: FID 250Column temp.: 210Injection port temp.: 225Carrier gas: 55 mL/min N (adjust so that the retention time of caffeine is about 6 minutes.)
PEG600+PEG1500 5+5% Shinwasorb-S 100/120
1. Acetone2. 1-Propanol
1
2
0 1 2 3 4 5 6
Column: 2.1 m x 3.2 mm I.D. GlassSample: Acetone, 1-Propanol Column temp.: 100Injection port temp.: 115Detector: FID 120Sample volume: 1 LCarrier gas: 50 mL/min N2
Column: 3.1 m x 3.2 mm I.D. GlassSample: HypromellosesColumn temp.: 110Injection port temp.: 150Detector: FID 150Sample volume: 2 LCarrier gas: 30 mL/min N2
Silicone DC 200 10% Shinwasorb-S 80/100
1. Methyl iodide2. iso-Propyl iodide3. n-Octane4. o-Xylene
0 5 10 15 20
1
2
3
4
PEG20M 5% Shinwasorb-S 60/80
Column: 3.1 m x 3.2 mm I.D. GlassSample: Ethanol, d-Comphor, Methyl salicylateColumn temp.: 160Injection port temp.: 200Detector: FID 200Sample volume: 2 LCarrier gas: 45 mL/min N2
1
2
3
1. Ethanol2. d-Comphor3. Methyl salicylate
0 3 6 9 12 15 18
522 Shimadzu GLC Ltd.
GC
07
GLC CATALOG 2017
Silicone OV-17 1% Shinwasorb-S 60/80
Column: 1.6 m x 3.2 mm I.D. GlassSample: /Column temp.: 210Injection port temp.: 270Detector: FID 270Sample volume: 2 LCarrier gas: 40 mL/min N2
0 1 2 3 4 5 6 7 8
1
2
1. 2.
4.3 (3)
Silicone OV-17 1% Shinwasorb-S 60/80
1
2
1. 2.
9.7(6)
0 2 4 6 8 10
Column: 1.6 m x 3.2 mm I.D. GlassSample: /Column temp.: 210Injection port temp.: 250Detector: FID 250Sample volume: 2 LCarrier gas: 45 mL/min N2
1
2
0 2 4 6 8 10
DEGA+H3PO4 2.5+0.5% Shinwasorb-S 80/100
1. n-valeric acid2. valproic acid
n-: 8.85
Column: 2.1 m x 3.2 mm I.D. GlassSample: n-valericacid, valproic acid/ formic acid, methyl acetate (1:1) Sample volume: 2.0 LColumn temp.: 145 Carrier gas: 35 mL/min N2Injection port temp.: 200 Detector: FID 200
0 5 10
1
2 1. acetone2. styrene
PEG20M 7.5% Shinwasorb-S 80/100
27641.03(8000.81.2 )
Column: 2.1 m x 3.2 mm I.D. GlassSample: acetone, styrene Sample volume: 5.0 LColumn temp.: 90 Carrier gas: 60 mL/min N2Injection port temp.: 200 Detector: FID 200
PEG6000 12.5% Shinwasorb-S 60/80
PEG6000 25% Chromosorb-W 60/80 AW-DMCS
12 3
0 1 0 2 0 3 0
1
2
3
0 1 0 2 0 3 0
1. ethanol2. n-ethyl caprylate3. L-menthol
1. ethanol2. n-ethyl caprylate3. L-menthol
12.6
5
6.5
5
Column: 2.1 m x 3.2 mm I.D. Glass Sample volume: 1.0 LSample: ethanol, n-ethyl caprylate, L-menthol Carrier gas: 33 mL/min N2 (Shinwasorb) Column temp.: 140 Carrier gas: 28 mL/min N2 (Chromosorb-W) Injection port temp.: 200 Detector: FID 200
Porapak-Q 80/100
0 5 10 15 20
12
Sunpak-A 80/100
0 5 10 15 20
1
2
8.1
2
12.0
2
1. ethanol2. 1-propanol
1. ethanol2. 1-propanol
Column: 1.6 m x 3.2 mm I.D. Glass Sample volume: 1.0 LSample: ethanol (solvent), 1-propanol Carrier gas: 30 mL/min N2 (Sunpak-A)Column temp.: 115 (Sunpak-A) / 125 (Porapak-Q) Carrier gas: 33 mL/min N2 (Porapak-Q) Injection port temp.: 200 Detector: FID 200
https://solutions.shimadzu.co.jp/glc 523
GC
07
GLC CATALOG 2017
12
0 10 20 30 40
DEGS 12.5% Shinwasorb-S 60/80
1. docosanoic acid methyl2. ethyl icosapentate
4.93.0
Column: 1.8 m x 4.0 mm I.D. Glass Sample volume: 3.0 LSample: docosanoicacid methyl, ethyl icosapentate Carrier gas: 47 mL/min N2 Column temp.: 210 Detector: FID 200Injection port temp.: 230
0 2 4 6 8
1
Sunpak-H 80/100
1. ethyl acetate
1445 1.04
5001.5
Column: 1.1 m x 3.2 mm I.D. Glass Sample volume: 1.0 LSample: ethyl acetate Carrier gas: 34 mL/min N2Column temp.: 130 Detector: FID 200Injection port temp.: 200
0 2 4 6 8 10
1
3
2
Sunpak-H 80/100
1. Chloroform2. Trichloroethylene3. N,N-dimethylformamide
4.2
3
Column: 1.1 m x 3.2 mm I.D. Glass Sample volume: 1.0 LSample: Chloroform, Trichloroethylene, N,N-dimethylformamideColumn temp.: 160
Detector: FID 200
Injection port temp.: 200Carrier gas: 45 mL/min N (Adjust so that the retention time of chloroform is about 2 minutes.)
https://solutions.shimadzu.co.jp/glc
!!
DMGET
524 Shimadzu GLC Ltd.
GC
07
GLC CATALOG 2017