2
For Installation and Sales: For Parts and Warranty: Free Match Gree Multi Split System Model Two Indoor Units Three Indoor Units GWHD (24)NK3JO 09+09 09+12 09+09+09 09+09+12 09+18 12+12 09+12+12 09+09+18 12+18 18+18 12+12+12 - Model One Indoor Units Two Indoor Units GWHD (18)NK3JO 09 09+09 12 12+12 Combinations Optional Wall Controller Model Unit GTH09BA-K3DNA1A/I GTH12BA-K3DNA1A/I GTH18BA-K3DNA1A/I GTH24BA-K3DNA1A/I Capacity Cooling/Heating kW 2.50/2.80 3.50/3.85 5.00/5.50 7.10/8.00 Air Flow Volume l/s 181 181 264 333 Sound Pressure Level dB(A) 40/38/36 40/38/36 45/42/40 48/46/44 Dehumidity Volume l/hr 0.8 1.4 1.8 2.5 Dimension (WxDxH) Outline mm 1220x700x225 1220x700x225 1220x700x225 1220x700x225 Package mm 1343x823x315 1343x823x315 1343x823x315 1343x823x315 Net weight/Gross weight kg 40/50 40/50 40/50 45/54 Connecting pipe Outer Diameter Liquid Pipe mm φ6.35 φ6.35 φ6.35 φ9.52 Gas Pipe mm φ9.52 φ9.52 φ12.7 φ15.9 Recommended Application Area m 2 11-17 16-21 23-33 32-48 Floor Ceiling (Indent only) Model Unit Compact Cassette Cassette GKH12BA-K3DNA2A/I GKH18BA-K3DNA2A/I GKH24BA-K3DNA1A/I Capacity Cooling/Heating kW 3.50/4.00 4.50/5.00 7.10/8.00 Air Flow Volume l/s 167 167 328 Sound Pressure Level dB(A) 46/44/42 46/44/42 39/37/35 Dehumidity Volume l/hr 1.4 1.8 2.5 Dimension (WxDxH) Outline mm 570x570x230 570x570x230 840x840x240 Package mm 851x731x325 851x731x325 963x963x325 Net weight/Gross weight kg 18/23 18/23 28/35 Panel Dimension (WxDxH) Outline mm 650x650x60 650x650x60 950x950x60 Package mm 733x673x117 733x673x117 1043x1028x130 Panel Net weight/Gross weight kg 18/23 18/23 28/35 Connecting pipe Outer Diameter Liquid Pipe mm φ6.35 φ6.35 φ9.52 Gas Pipe mm φ9.52 φ12.7 φ15.9 Recommended Application Area m 2 16-24 24-35 32-47 Compact Cassette/Cassette (Indent only) Optional Wall Controller Item Nominal Operating Conditions Outdoor Conditions Indoor Conditions Outdoor Conditions DB (°C) WB (°C) DB (°C) WB (°C) DB (°C) Cooling 35 24 27 19 -15~43 Heating 7 6 20 15 -15~24 Model Two Indoor Units Three Indoor Units Four / Five Indoor Units GWHD (42)NK3JO 09+09 18+18 09+09+09 09+18+18 09+09+09+09 09+09+09+09+09 09+12 18+21 09+09+12 09+18+21 09+09+09+12 09+09+09+09+12 09+18 18+24 09+09+18 09+21+21 09+09+09+18 - 09+21 21+21 09+09+21 12+12+12 09+09+09+21 - 09+24 21+24 09+09+24 12+12+18 09+09+12+21 - 12+21 24+24 09+12+12 12+12+21 09+09+12+18 - 12+18 - 09+12+18 12+12+24 09+12+12+12 - 12+21 - 09+12+21 12+18+18 09+12+12+18 - 12+24 - 09+12+24 12+18+21 09+12+12+19 - Model Two Indoor Units Three Indoor Units Four Indoor Units GWHD (36)NK3JO 09+09 12+24 09+09+09 09+12+24 09+09+09+09 09+12 18+18 09+09+12 09+18+18 09+09+09+12 09+18 18+21 09+09+18 09+18+21 09+09+09+18 09+21 18+24 09+09+21 12+12+12 09+09+09+21 09+24 21+21 09+09+24 12+12+18 09+09+12+12 12+21 21+24 09+12+12 12+12+21 09+09+12+18 12+18 24+24 09+12+18 12+12+24 09+12+12+12 12+21 - 09+12+21 12+18+18 12+12+12+12 Model Two Indoor Units Three Indoor Units Four Indoor Units GWHD (28)NK3JO 09+09 09+12 09+09+09 09+09+12 09+09+09+09 09+18 12+12 09+12+12 09+12+18 09+09+09+12 12+18 18+18 12+12+18 09+09+18 09+09+12+12 - - 12+12+12 - - Combinations Find out more at www.greeonline.com www.greeonline.com 0800 BUY GREE (NZ) 1800 GREE 4 ME (AU) GREE NZ & AUS NOW ON FACEBOOK!

Gree Freematch Brochure

Embed Size (px)

DESCRIPTION

Gree Multi Split System

Citation preview

Page 1: Gree Freematch Brochure

For Installation and Sales: For Parts and Warranty:

Free MatchGree Multi Split System

Model Two Indoor Units Three Indoor Units

GWHD (24)NK3JO

09+09 09+12 09+09+09 09+09+12

09+18 12+12 09+12+12 09+09+18

12+18 18+18 12+12+12 -

Model One Indoor Units Two Indoor Units

GWHD (18)NK3JO09 09+09

12 12+12

Combinations

Optional Wall Controller

Model Unit GTH09BA-K3DNA1A/I GTH12BA-K3DNA1A/I GTH18BA-K3DNA1A/I GTH24BA-K3DNA1A/I

Capacity Cooling/Heating kW 2.50/2.80 3.50/3.85 5.00/5.50 7.10/8.00

Air Flow Volume l/s 181 181 264 333

Sound Pressure Level dB(A) 40/38/36 40/38/36 45/42/40 48/46/44

Dehumidity Volume l/hr 0.8 1.4 1.8 2.5

Dimension(WxDxH)

Outline mm 1220x700x225 1220x700x225 1220x700x225 1220x700x225

Package mm 1343x823x315 1343x823x315 1343x823x315 1343x823x315

Net weight/Gross weight kg 40/50 40/50 40/50 45/54

Connecting pipe Outer Diameter

Liquid Pipe mm φ6.35 φ6.35 φ6.35 φ9.52

Gas Pipe mm φ9.52 φ9.52 φ12.7 φ15.9

Recommended Application Area m2 11-17 16-21 23-33 32-48

Floor Ceiling (Indent only)

Model UnitCompact Cassette Cassette

GKH12BA-K3DNA2A/I GKH18BA-K3DNA2A/I GKH24BA-K3DNA1A/I

Capacity Cooling/Heating kW 3.50/4.00 4.50/5.00 7.10/8.00

Air Flow Volume l/s 167 167 328

Sound Pressure Level dB(A) 46/44/42 46/44/42 39/37/35

Dehumidity Volume l/hr 1.4 1.8 2.5

Dimension(WxDxH)

Outline mm 570x570x230 570x570x230 840x840x240

Package mm 851x731x325 851x731x325 963x963x325

Net weight/Gross weight kg 18/23 18/23 28/35

Panel Dimension(WxDxH)

Outline mm 650x650x60 650x650x60 950x950x60

Package mm 733x673x117 733x673x117 1043x1028x130

Panel Net weight/Gross weight kg 18/23 18/23 28/35

Connecting pipe Outer Diameter

Liquid Pipe mm φ6.35 φ6.35 φ9.52

Gas Pipe mm φ9.52 φ12.7 φ15.9

Recommended Application Area m2 16-24 24-35 32-47

Compact Cassette/Cassette (Indent only)

Optional Wall Controller

Contact:AUS 1800 7325 2653

NZ 0800 11 66 90www.realcold.com

For Installation and Sales:

Gree Hansol Hi-wall Inverter Split SystemsGWH09TA-K3DNA1B

GWH12TB-K3DNA1B

GWH18TC-K3DNA1B

GWH24TD-K3DNA1B

GWH28TD-K3DNA1B

Realcold Part # Australia AC4301 AC4302 AC4303 AC4304 AC4305

New Zealand AC7301 AC7302 AC7303 AC7304 AC7305

Performance

CapacityCooling

kW

2.6 3.5 5.3 7.0 8.0

Heating 3.0 4.0 5.8 7.6 8.4

Capacity Range (min~max)

Cooling (0.57~3.2) (0.66~3.9) (0.7~6.5) (1.2~8.0) (1.0~8.8)

Heating (0.57~3.2) (0.7~4.3) (0.95~7.3) (1.4~10) (1.3~11)

InputCooling

kW

0.67 0.90 1.52 2.0 2.39

Heating 0.77 1.03 1.66 2.17 2.51

Input Range(min~max)

Cooling (0.13~1.2) (0.175~1.23) (0.32~2.5) (0.42~3.5) (0.32~4.2)

Heating (0.13~1.2) (0.175~1.23) (0.32~2.5) (0.42~3.5) (0.32~4.2)

Energy Label 2011

Cooling Stars

3 3 2 2 2

Heating 3 3 2 2 2

AEER Cool T1 100% W/W 3.86 3.77 3.27 3.48 3.36

ACOP Heat T1 100% W/W 3.84 3.86 3.29 3.47 3.37

Moisture Removal l/h 0.8 1.4 1.8 2.5 2.7

Airflow H/S l/s 153 208 264 333 333

Sound Pressure Level (JIS C9612)

Indoor db 37/32/28/25/23/21 39/34/31/28/26/23 45/41/39/36/33/30 49/45/43/41/39/36 49/45/43/41/39/36

Outdoor db 50 52 56 56 58

Electrical

Power Supply 230V/50Hz/1ph

Recommended Circuit Breaker Amp 10 15 20

Current Cool/Heat T1 Amp 2.91/3.35 3.91/4.48 7.28/8.09 8.87/9.63 10.6/11.14Dimensions and Weights

External Dimensions (HxWxD)

IndoorOutdoor

mm292x806x209540x848x320

292x866x209592x848x320

319x1018x230700x955x396

326x1178x264790x980x427

326x1178x264790x980x427

Nett WeightIndoor

kg10 11 16 18 18

Outdoor 34 36 50 68 69Installation

Refrigerant Piping

Liquid Line

mm(in)

6.35 (1/4”)

Gas Line 9.52 (3/8”) 15.88 (5/8")

Conn Method Flare

Refrigerant R410A

Pre-charged amount

kg 1.07 1.28 1.6 2.3 2.4

m 7.5m 7.5m 7.5m 7.5m 7.5

Additional gas charge g/m 20 20 50 50 50

Power Supply Indoor (2.5mm)

Control wiring (included) 3 Core plus Earth (4 cores) 1mm length 5m

Maximum Piping Length H/L m 10/15 10/20 10/25 10/25 10/25

Operating Temperature Range °C -15~43 -15~43 -15~43 -15~43 -15~43

MEPSIV 2 YEAR COMMERCIAL WARRANTY 5 YEAR

DOMESTIC WARRANTY

Z1403

For Parts and Warranty:Item

Nominal Operating Conditions

Outdoor Conditions Indoor Conditions Outdoor Conditions

DB (°C) WB (°C) DB (°C) WB (°C) DB (°C)

Cooling 35 24 27 19 -15~43

Heating 7 6 20 15 -15~24

Model Two Indoor Units Three Indoor Units Four / Five Indoor Units

GWHD (42)NK3JO

09+09 18+18 09+09+09 09+18+18 09+09+09+09 09+09+09+09+09

09+12 18+21 09+09+12 09+18+21 09+09+09+12 09+09+09+09+12

09+18 18+24 09+09+18 09+21+21 09+09+09+18 -

09+21 21+21 09+09+21 12+12+12 09+09+09+21 -

09+24 21+24 09+09+24 12+12+18 09+09+12+21 -

12+21 24+24 09+12+12 12+12+21 09+09+12+18 -

12+18 - 09+12+18 12+12+24 09+12+12+12 -

12+21 - 09+12+21 12+18+18 09+12+12+18 -

12+24 - 09+12+24 12+18+21 09+12+12+19 -

Model Two Indoor Units Three Indoor Units Four Indoor Units

GWHD (36)NK3JO

09+09 12+24 09+09+09 09+12+24 09+09+09+09

09+12 18+18 09+09+12 09+18+18 09+09+09+12

09+18 18+21 09+09+18 09+18+21 09+09+09+18

09+21 18+24 09+09+21 12+12+12 09+09+09+21

09+24 21+21 09+09+24 12+12+18 09+09+12+12

12+21 21+24 09+12+12 12+12+21 09+09+12+18

12+18 24+24 09+12+18 12+12+24 09+12+12+12

12+21 - 09+12+21 12+18+18 12+12+12+12

Model Two Indoor Units Three Indoor Units Four Indoor Units

GWHD (28)NK3JO

09+09 09+12 09+09+09 09+09+12 09+09+09+09

09+18 12+12 09+12+12 09+12+18 09+09+09+12

12+18 18+18 12+12+18 09+09+18 09+09+12+12

- - 12+12+12 - -

Combinations

Find out more atwww.greeonline.com

www.greeonline.com0800 BUY GREE (NZ)1800 GREE 4 ME (AU)

GREE NZ & AUS NOW ON FACEBOOK!

Page 2: Gree Freematch Brochure

Why Choose a Gree Free Match System?The Gree Free Match System provides the flexibility of heating or cooling your entire home or office with up to five indoor units with just one outdoor unit. This means less noise and less space taken up by large outdoor units all powering multiple indoor units. The indoor units can be different types and/or capacities which means you can customise your heating and cooling needs specifically for your home or office.

For example you can choose a 5kW Hansol Hi Wall Unit for your lounge, a 2.5kW Cozy Hi Wall for your master bedroom and a 3.5 kW Cassette for your kitchen and they can all be run from one outdoor unit.

This allows you complete temperature control over your entire home or office environment which gives increased comfort and greater energy efficiency.

All Gree Air Conditioners are fitted with Gree’s G10 Inverter Technology. Inverter air conditioners are more powerful and more energy efficient than fixed speed air conditioners. Gree G10 Inverter's use highly sensitive signal processors to vary the speed of the air conditioner to match the temperature required. When the desired temperature is achieved, the G10 Inverter technology ensures it's continually maintained with minimal noise.

What Are The Benefits of the G10 Inverter Technology?Greater Power Savings

The G10 Inverter can save approximately 20% more power year on year compared to a fixed speed air conditioner. In addition to this, Gree Air Conditioners use less than 1W of power in standby mode.

Low Noise

The Gree 180° Sine Wave DC Speed Varying Technology offers precise control giving continuous operation and accurate temperature stability. By operating over a wider frequency the compressor is less stressed giving superior reliability while offering lower noise levels.

Increased Comfort

The superior control of the G10 Inverter means that even in extreme outdoor temperatures, the air conditioner will maintain the set temperature within ±0.5°C.

Controlling the Gree Free Match SystemEach indoor unit has its own controller, this means you can perfectly customise the temperature in each room without affecting the other rooms. Hi Wall units have remote controls and the Cassette and Ducted have wall mounted controllers.

Model UnitGWHD(18)

NK3JOGWHD(24)

NK3JOGWHD(28)

NK3JOGWHD(36)

NK3JOGWHD(42)

NK3JO

Power SupplyPhase/Voltage/Frequency Ph/V/Hz 1/220-240/50 1/220-240/50 1/220-240/50 1/220-240/50 1/220-240/50

Power Supply Mode - Outdoor

CapacityCooling kW 5.00 (2.05-6.20) 7.10 (2.20-10.00) 8.00 (2.20-10.00) 10.00 (2.60-11.00) 12.00 (2.60-12.00)

Heating kW 5.60 (2.50-6.65) 8.50 (3.60-11.00) 9.30 (2.80-11.00) 11.20 (3.00-12.00) 12.00 (3.00-13.50)

Power inputCooling kW 1.55 (0.68-2.70) 2.20 (0.65-4.55) 2.48 (0.65-4.55) 3.00 (1.00-3.80) 3.55 (1.00-4.00)

Heating kW 1.55 (0.68-2.70) 2.35 (0.65-4.55) 2.58 (0.98-4.55) 3.20 (1.00-3.80) 3.27 (1.00-4.00)

Current Cooling/Heating A 6.96/6.88 10.65/10.43 11.05/11.45 13.0/14.0 15.40/14.15

EER/COP W/W 3.23/3.61 3.22/3.62 3.22/3.60 3.33/3.60 3.20/3.70

Maximum Indoor unit connection quantity set 2 3 4 4 5

Sound pressure level dB(A) 56 58 58 61 61

Compressor type - Inverter Rotary

Fuse current A 25 30 30 30 30

Circuit breaker current A 20 25 25 25 25

Dimension(WxDxH)

Outline mm 955x396x700 980x427x790 980x427x790 1087x440x1103 1087x440x1103

Package mm 1029x458x750 1083x488x855 1083x448x855 1173x483x1130 1173x483x1130

Net weight/Gross weight kg 50/55 69/74 69/74 90/98 90/98

Refrigerant charge volume kg 1.40 2.20 2.20 3.65 3.65

Outdoor unit operation rangeCooling °C -5–48 -5–48 -5–48 -5–48 -5–48

Heating °C -15–24 -15–24 -15–24 -15–24 -15–24

Connection pipe

Precharged length m 10 20 20 25 25

Outer diameter liquid pipe mm φ6.35x2 φ6.35x3 φ6.35x4 φ6.35x4 φ6.35x5

Outer diameter gas pipe mm φ9.52x2 φ9.52x3 φ9.52x4 φ9.52x4 φ9.52x4

Max distance height m 10 10 10 15 15

Max distance length m 10 10 10 25 25

Remarks:1. Because of the continuing improvement on product, all specification are subject to change without prior notice.2. Above outdoor units specification is according to a fixed combination with Hansole indoor Series withch comply with AS/NZS 38233. Above outdoor units are standard with DRED mode (Demand Response Enabling Device) which compy with AS/NZS 4755.

Outdoor Units

Capacity Index (BTU/h) 7000 9000 12000 18000 21000 24000 28000

Wall MountedHansol • • • • •

Cozy • • • • •

Duct type • • • • •

Compact Cassette • •

Cassette •

Floor Ceiling (Indent only) • • • •

Indoor Units

Gree Free Match Systems

Model UnitGWH09TA-K3D-

NA1B/IGWH12TB-K3D-

NA1B/IGWH18TC-K3D-

NA1B/IGWH24TD-K3D-

NA1B/IGWH28TD-K3D-

NA1B/I

Capacity Cooling/Heating kW 2.60/3.00 3.50/4.00 5.30/5.80 7.00/7.60 8.00/8.40

Air Flow Volume l/s 153 208 264 333 333

Sound Pressure Level dB(A) 40/37/32/28/25/23/21 42/39/34/31/28/26/23 49/45/41/39/36/33/30 51/49/45/43/41/39/36 51/49/45/43/41/39/36

Dehumidity Volume l/hr 0.8 1.4 1.8 2.5 2.7

Dimension(WxDxH)

Outline mm 806x292x209 866x292x209 1018x319x230 1178x326x264 1178x326x264

Package mm 888x377x297 945x377x297 1097x397x340 1256x414x364 1256x414x364

Net weight/Gross weight kg 10/13 11/14 16/19 18/24 18/24

Connecting pipe Outer Diameter

Liquid Pipe mm φ6.35 φ6.35 φ6.35 φ6.35 φ6.35

Gas Pipe mm φ9.52 φ9.52 φ15.9 φ15.9 φ15.9

Recommended Application Area m2 12-18 16-21 24-35 32-44 40-54

Hansol

Model UnitGWH09MB-K3D-

NA2H/IGWH12MB-K3D-

NA2H/IGWH18MC-K3D-

NA2H/IGWH24MD-K3D-

NA2H/IGWH28ME-K3D-

NA2H/I

Capacity Cooling/Heating kW 2.60/2.80 3.50/3.80 5.30/5.85 6.30/7.00 8.00/8.70

Air Flow Volume l/s 161 167 236 264 333

Sound Pressure Level dB(A) 40/37/35/32 42/39/36/33 46/44/40/35 51/45/42/39 51/48/43/40

Dehumidity Volume l/hr 0.8 1.2 1.8 2.5 2.7

Dimension(WxDxH)

Outline mm 548x275x180 548x275x180 940x298x200 1007x315x219 1178x326x253

Package mm 918x258x370 918x258x370 1013x288x395 1076x398x328 1268x420x358

Net weight/Gross weight kg 11/14 11/14 13/17 16/21 17.5/23.5

Connecting pipe Outer Diameter

Liquid Pipe mm φ6.35 φ6.35 φ6.35 φ6.35 φ6.35

Gas Pipe mm φ9.52 φ9.52 φ12.79 φ15.9 φ15.9

Recommended Application Area m2 12-18 16-21 24-35 29-42 40-54

Cozy

Model UnitGFH09EA-D3D-

NA1A/IGFH12EA-D3D-

NA1A/IGFH18EA-D3D-

NA1A/IGFH21EA-D3D-

NA1A/IGFH24EA-D3D-

NA1A/I

Capacity Cooling/Heating kW 2.50/2.80 3.50/3.80 4.50/5.50 6.00/6.60 7.00/8.00

Air Flow Volume l/s 125 153 194 278 278

External Static Pressure Pa 0~10 0~10 0~10 0~15 0~15

Sound Pressure Level dB(A) 37/34/31 39/35/32 41/37/33 42/38/34 42/38/34

Dehumidity Volume l/hr 0.8 1.4 1.8 2 2.5

Dimension(WxDxH)

Outline mm 700x615x200 700x615x200 900x615x200 1100x615x200 1100x615x200

Package mm 898x743x305 898x743x305 1123x743x305 1323x743x305 1323x743x305

Net weight/Gross weight kg 22/27 23/29 27/36 31/41 31/41

Connecting pipe Outer Diameter

Liquid Pipe mm φ6.35 φ6.35 φ6.35 φ9.52 φ9.52

Gas Pipe mm φ9.52 φ9.52 φ12.7 φ15.9 φ15.9

Recommended Application Area m2 10-14 12-18 20-30 27-40 32-44

Slim Ducted (Built-in water pump) (Indent only)

Optional Wall Controller

Optional ExtrasWireless Remote Control

By installing Pebble Wifi you can also use your Apple or Android device to control each indoor unit in the Gree Free Match System.

Information for InstallersWide Voltage Range Operation

The Gree Free Match System can operate safely within 198V and 264V which means that voltage variations are less likely to cause damage.

Auto Restart

The indoor units will automatically restart with the same mode and fan settings after a power outage.