6
   T    h   e    i   n    f   o   r   m   a    t    i   o   n   p   r   o   v    i    d   e    d    i   n    t    h    i   s    d   o   c   u   m   e   n    t   a    t    i   o   n   c   o   n    t   a    i   n   s   g   e   n   e   r   a    l    d   e   s   c   r    i   p    t    i   o   n   s   a   n    d    /   o   r    t   e   c    h   n    i   c   a    l   c    h   a   r   a   c    t   e   r    i   s    t    i   c   s   o    f    t    h   e   p   e   r    f   o   r   m   a   n   c   e   o    f    t    h   e   p   r   o    d   u   c    t   s   c   o   n    t   a    i   n   e    d    h   e   r   e    i   n  .            s    d   o   c   u   m   e   n    t   a    t      o   n      s   n   o    t      n    t   e   n    d   e    d   a   s   a   s   u    b   s    t       t   u    t   e      o   r   a   n    d      s   n   o    t    t   o    b   e   u   s   e    d      o   r    d   e    t   e   r   m      n      n   g   s   u       t   a    b             t   y   o   r   r   e         a    b             t   y   o       t      e   s   e   p   r   o    d   u   c    t   s      o   r   s   p   e   c            c   u   s   e   r   a   p   p         c   a    t      o   n   s  .    I    t    i   s    t    h   e    d   u    t   y   o    f   a   n   y   s   u   c    h   u   s   e   r   o   r    i   n    t   e   g   r   a    t   o   r    t   o   p   e   r    f   o   r   m     t    h   e   a   p   p   r   o   p   r    i   a    t   e   a   n    d   c   o   m   p    l   e    t   e   r    i   s    k   a   n   a    l   y   s    i   s  ,   e   v   a    l   u   a    t    i   o   n   a   n    d    t   e   s    t    i   n   g   o    f    t    h   e   p   r   o    d   u   c    t   s   w    i    t    h   r   e   s   p   e   c    t    t   o    t    h   e   r   e    l   e   v   a   n    t   s   p   e   c    i    f    i   c   a   p   p    l    i   c   a    t    i   o   n   o   r   u   s   e    t    h   e   r   e   o    f  .    N   e    i    t    h   e   r    S   c    h   n   e    i    d   e   r    E    l   e   c    t   r    i   c    I   n    d   u   s    t   r    i   e   s    S    A    S   n   o   r   a   n   y   o    f    i    t   s   a    f    f    i    l    i   a    t   e   s   o   r   s   u    b   s    i    d    i   a   r    i   e   s   s    h   a    l    l    b   e   r   e   s   p   o   n   s    i    b    l   e   o   r    l    i   a    b    l   e    f   o   r   m    i   s   u   s   e   o    f    t    h   e    i   n    f   o   r   m   a    t    i   o   n   c   o   n    t   a    i   n   e    d    h   e   r   e    i   n  .  Aug 25, 2014 1 Product data sheet Characteristics XACA871 pendant control station XAC-A - 8 pushbuttons Main Range of product Harmony XAC Product or component type Pendant control station Control station name XACA Control s tation type Double insulated Enclosure material Polypropylene Electrical circuit t ype Control circuit Enclosure type Complete ready for use Control station applica- tion Control of single speed hoist motor Control station compo- sition 8 pushbuttons Control button t ype Thir d p ushbutton 1 NO r ig ht, slow Sixth pushbutton 1 NO reverse, slow Seventh pushbutton 1 NO I Second pushbutton 1 NO lower, slow Fourth pushbutton 1 NO left, slow First pushbutton 1 NO raise, slow Fifth pushbutton 1 NO forward slow Eighth pusbutton 1 NC O Contact block name ZB2BE102 for eighth direction ZB2BE101 for each direction (except eighth) Mec hanical int erlo ckin g With mechan ical int erl ocking bet ween pai rs Complementary Control station colour Yellow Connections - terminals Screw clamp terminals, connection capacity: 1 x 0.5...2 x 1.5 mm² with cable end Screw clamp terminals, connection capacity: 1 x 0.5...1 x 2.5 mm² without cable end Mechanical durability 1000000 cycles Cable entry Rubber sleeve with stepped entry, cable outer diameter: 8...26 mm Contact code designation Q600 DC-13, Ue = 600 V, Ie = 0.1 A conforming to IEC 60947-5-1 appendix A Q600 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A  A600 AC-15, Ue = 600 V , Ie = 1.2 A conforming to IEC 60947-5-1 appendix A  A600 AC-15, Ue = 240 V , Ie = 3 A conforming to IEC 60 947-5-1 appendix A [Ithe] conventional enclosed thermal current 10 A [Ui] rated insulation voltage 600 V (degree of pollution: 3) [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-1 Contacts operation Slow-break Resistance across terminals <= 25 MOhm Operating force 8 N for eighth pushbutton 10 N for pushbutton Short circuit protection 10 A fuse protection by cartridge fuse type gG Rated operational power in W 65 W DC-13 for 1000000 cycles, operating rate = 60 cyc/mn at 24 V, load factor  = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 48 W DC-13 for 1000000 cycles, operating rate = 60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 40 W DC-13 for 1000000 cycles, operating rate = 60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C Terminals description ISO n°1 (13-14)NO Terminals description ISO 2 (11-12)NC Terminal identifier (11-12)NC (13-14)NO Product weight 0.94 kg

Harmony Xac Xaca871

Embed Size (px)

Citation preview

  • 5/20/2018 Harmony Xac Xaca871

    1/5

    The

    informa

    tionprov

    ide

    dinthisdocumen

    tationcon

    tainsgenera

    ldescrip

    tionsan

    d/or

    tec

    hn

    ica

    lc

    harac

    teris

    ticso

    ftheperformanceo

    fthepro

    du

    ctscon

    taine

    dhere

    in.

    Thisdocumen

    tation

    isno

    tinten

    de

    dasasu

    bs

    tituteforan

    disno

    ttobeuse

    dfor

    de

    term

    iningsu

    ita

    bilityorre

    lia

    bilityo

    fthesepro

    duc

    tsforspeci

    ficuserapp

    lica

    tions.

    Itisthe

    du

    tyo

    fanysuc

    huse

    ror

    integra

    tor

    toperform

    theappropria

    tean

    dcomp

    leter

    iskana

    lys

    is,

    eva

    lua

    tionan

    dtes

    tingo

    fthepro

    duc

    tsw

    ith

    respec

    ttothere

    levan

    tspec

    ificapp

    lica

    tionoruse

    thereo

    f.

    Ne

    ither

    Sc

    hne

    ider

    Elec

    tricIn

    dus

    tries

    SASnoranyo

    fitsa

    ffiliatesorsu

    bs

    idiariess

    hal

    lberespons

    ibleor

    lia

    bleform

    isuseo

    fthe

    informa

    tionco

    ntaine

    dhere

    in.

    Aug 25, 2014

    1

    Product data sheetCharacteristics

    XACA871pendant control station XAC-A - 8 pushbuttons

    Main

    Range of product Harmony XAC

    Product or component

    type

    Pendant control station

    Control station name XACA

    Control station type Double insulated

    Enclosure material Polypropylene

    Electrical circuit type Control circuit

    Enclosure type Complete ready for use

    Control station applica-

    tion

    Control of single speed hoist motor

    Control station compo-

    sition

    8 pushbuttons

    Control button type Third pushbutton 1 NO right, slow

    Sixth pushbutton 1 NO reverse, slow

    Seventh pushbutton 1 NO I

    Second pushbutton 1 NO lower, slow

    Fourth pushbutton 1 NO left, slow

    First pushbutton 1 NO raise, slow

    Fifth pushbutton 1 NO forward slow

    Eighth pusbutton 1 NC O

    Contact block name ZB2BE102 for eighth direction

    ZB2BE101 for each direction (except eighth)

    Mechanical interlocking With mechanical interlocking between pairs

    ComplementaryControl station colour Yellow

    Connections - terminals Screw clamp terminals, connection capacity: 1 x 0.5...2 x 1.5 mm with cable end

    Screw clamp terminals, connection capacity: 1 x 0.5...1 x 2.5 mm without cable

    end

    Mechanical durability 1000000 cycles

    Cable entry Rubber sleeve with stepped entry, cable outer diameter: 8...26 mm

    Contact code designation Q600 DC-13, Ue = 600 V, Ie = 0.1 A conforming to IEC 60947-5-1 appendix A

    Q600 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A

    A600 AC-15, Ue = 600 V, Ie = 1.2 A conforming to IEC 60947-5-1 appendix A

    A600 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A

    [Ithe] conventional enclosed thermal current 10 A

    [Ui] rated insulation voltage 600 V (degree of pollution: 3)

    [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-1

    Contacts operation Slow-break

    Resistance across terminals

  • 5/20/2018 Harmony Xac Xaca871

    2/5

    2

    Environment

    Standards EN/IEC 60204-32

    EN/IEC 60947-5-1

    UL 508

    CSA C22.2 No 14

    Product certifications CCC

    GOST

    Protective treatment TH

    Ambient air temperature for operation -25...70 C

    Ambient air temperature for storage -40...70 C

    Vibration resistance 15 gn (f = 10...500 Hz) conforming to IEC 60068-2-6

    Shock resistance 100 gn conforming to IEC 60068-2-27

    Class of protection against electric shock Class II conforming to IEC 61140

    IP degree of protection IP65 conforming to IEC 60529

    IK degree of protection IK08 conforming to EN 50102

  • 5/20/2018 Harmony Xac Xaca871

    3/5

    3

    Product data sheetDimensions Drawings

    XACA871

    Dimensions

    Below drawing shows a product with 6 cut-outs. Select the number of cut-outs according to the product characteristics in order to get b, b1

    and c dimensions.

    (1) For 2 and 3-way XAC A stations.

    (2) For 4 to 8-way XAC A stations.

    (3) With trigger action Emergency stop head operator

    (4) Internal

    Dimensions in mm

    Number of cut-outs 2 3 4 5 6 8 12

    b 314 314 440 440 500 560 680

    b1 190 190 250 250 310 370 490

    c 80 80 80 80 80 80 92

    Dimensions in in.

    Number of cut-outs 2 3 4 5 6 8 12

    b 12.36 12.36 17.32 17.32 19.68 22.05 26.77

    b1 7.48 7.48 9.84 9.84 12.20 14.57 19.29

    c 3.15 3.15 3.15 3.15 3.15 3.15 3.62

  • 5/20/2018 Harmony Xac Xaca871

    4/5

    4

    Product data sheetConnections and Schema

    XACA871

    Control of Single-Speed Reversing Motor

    With ZBE2BE101 + ZB2BE102 contacts blocks, to be ordered separately

  • 5/20/2018 Harmony Xac Xaca871

    5/5

    5

    Product data sheetPerformance Curves

    XACA871

    Rated Operational Power

    AC Supply 50/60 Hz Inductive Circuit

    Operating rate: 3600 operating cycles/hour. Load factor: 0.5.

    Millions of operating cycles, AC-15 utilization category

    Ithe Thermal current

    (A) Current

    DC Supply

    Operating rate: 3600 operating cycles/hour. Load factor: 0.5.

    Power broken in W for 1 million operating cycles, DC-13 utilization category

    Voltage V 24 48 120

    Inductive circuit W 65 48 40