4
TubaVent PO Box 565, Balmain, NSW, 2041, Australia P +61 2 9810 6947 F +61 2 8072 1556 [email protected] www.coremed.com.au

Home - Welcome to Coremed - TubaVent · 2018-09-26 · Tuba Eustachii, p ars c t il g ne Tuba Eustachii, pars ossea Cause of tube ventilation disorders Principle of balloon dilatation

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Home - Welcome to Coremed - TubaVent · 2018-09-26 · Tuba Eustachii, p ars c t il g ne Tuba Eustachii, pars ossea Cause of tube ventilation disorders Principle of balloon dilatation

TubaVent

Burghof 14

51491 Overath / Germany

Tel.: +49 (0) 2206 / 90 81 - 0

Fax: +49 (0) 2206 / 90 81 -13

[email protected]

www.spiggle-theis.com

GmbH

PO Box 565, Balmain, NSW, 2041, AustraliaP +61 2 9810 6947 F +61 2 8072 [email protected] www.coremed.com.au

Page 2: Home - Welcome to Coremed - TubaVent · 2018-09-26 · Tuba Eustachii, p ars c t il g ne Tuba Eustachii, pars ossea Cause of tube ventilation disorders Principle of balloon dilatation

Prof. Dr. med. Holger Sudhoff, FRCS (Lon), FRCPathSenior consultant of the Klinikum Bielefeld (Ear, nose and throat, head and neck surgery clinic, Bielefeld medical centre)

Established and proven therapy concept in the treatment of chronic tube ventilation disorders

“The use of microscopic and endoscopic technologies has revolutionised medicine and is state of the art today. With the development of balloon catheters, for example for the dilata-tion of heart coronaries, previously inconceivable revolutiona-ry treatment concepts emerged. The transfer of this technology to the dilatation of the auditory tube provides the possibility

infections. Particularly for chronic tube dysfunctions or middle ear pathologies, there is now the opportunity to therapeutically approach the black box of otolaryngology. The new treatment

chronic tube dysfunction and to provide our patients with a new treatment possibility for this previously untreatable condition.“

Musculus tensorveli palatini

Torustubarius

Tuba Eustachii,pars cartilaginea

Tuba Eustachii,pars ossea

Cause of tube ventilation disorders

Principle of balloon dilatation

Chronic recurring infections Allergies Laryngopharyngeal reflux Inflammatory disorder of the mucosa Anatomically caused obstruction Adenoid vegetations, e.g. “polyps“ Glue Tube

Balloon catheter with olive-shaped tip The catheter was optimally adapted to the single use insertion instrument and equipped with an especially rounded tip.

TubaVent short

TubaVent short

Balloon catheter for the Eustachian Tube, WL 236 mm, balloon 3.28 x 20 mm, sterile

2080-1236320

The catheter dimensions re perfectly a a dapted to the length of the single use insertion instrument,

An olive-shaped tip ensures enhanced protection of the mucosa, also in child

which defines the process and prevents the catheter from being pushed too far into the Eustachian Tube

ren.

Inserting the catheter

Dilating the auditory tube

Page 3: Home - Welcome to Coremed - TubaVent · 2018-09-26 · Tuba Eustachii, p ars c t il g ne Tuba Eustachii, pars ossea Cause of tube ventilation disorders Principle of balloon dilatation

TubaInsert®

Single use insertion instrument

Type Ulm, sterile, 10 pieces/box

Type 45°, sterile, 10 pieces/box, short curve

Type 70°, sterile, 10 pieces/box

Oberstarzt Prof. Dr. med. habil. Matthias TischHonorary Doctorate in MedicineJordan University of Science and Technology (JUST),Ärztlicher Direktor Klinik und Poliklinik für HNO-Heilkunde, Kopf- und HalschirurgieBundeswehrkrankenhaus Ulm

“The new TubaInsert®

of a suction tube and an insertion aid. The smaller disposable insertion instrument offers improved functionality and better handling particularly in children, and allows a more direct contact with the patient.”

The well-known reliability of the sterilisable combined insertion instrument applies to the single use insertion instrument as well. The single use insertion instrument was developed based on experience and in close cooperation with its users.

Improved handling due to a shorter insertion distance in case of narrow anatomic conditions

Four different geometries to match the anatomy are offered Optimal ergonomics and a serrated surface allow comfortable and safe handling

Compatible in length with TubaVent short

Single use – no sterilization needed

2080-2010

2080-2070

2080-2045

Inflation pump

2080-9030020

Inflation pump (20ml) with 100 cm extension tube Pressure gauge with PSI scale Luer lock connector Single Use

Page 4: Home - Welcome to Coremed - TubaVent · 2018-09-26 · Tuba Eustachii, p ars c t il g ne Tuba Eustachii, pars ossea Cause of tube ventilation disorders Principle of balloon dilatation

GmbHBurghof 14

51491 Overath / Germany

Tel.: +49 (0) 2206 / 90 81 - 0

Fax: +49 (0) 2206 / 90 81 -13

[email protected]

www.spiggle-theis.de

www.spiggle-theis.com

PO Box 565, Balmain, NSW, 2041, AustraliaP +61 2 9810 6947 F +61 2 8072 [email protected] www.coremed.com.au

FL_TubaVent_AUS

© 2015 by Spiggle & Theis Medizintechnik GmbH

Please note that due to production, the dimensions of the products may vary slightly to those stated. Please note also that not all goods might be for sale in your country.

CM

055_

TUBO

VEN

T_4p

p_04

18