HPLC - .HPLC HPLC Specialist ... HPLC COLUMNS Table1. HPLC phase specifications. ... chemco-column英文カタログ.ppt

  • View
    229

  • Download
    3

Embed Size (px)

Text of HPLC - .HPLC HPLC Specialist ... HPLC COLUMNS Table1. HPLC phase specifications. ......

  • HPLCHPLC Specialist

    Chemco Scientific Co., Ltd.

    HPLC COLUMNS ChemcosorbChemcobondQUICKSORB

    &Application Data

    URL ; http://www.chemco.jp/E-Mail ; info@chemco.jp

    mailto:info@chemco.jphttp://www.chemco.jphttp://www.chemco.jpmailto:info@chemco.jp

  • URL ; http://www.chemco.jp/!E-mail : info@chemco.jp

    CHEMCOSORB U-seriesCHEMCOSORB U-series packings are prepared from special silica with extremely large surface area (6nm pore,

    600 m2/g). With this property of base material and our modification process, CHEMCOSORB U-series results in

    more retentive and unique phase than other bland column. Wide range of chemical phase, ODS, C8, Diphenyl,

    TMS, CN, NH2 and Si are available.

    CHEMCOSORB 5-ODS-UH has very high carbon content (30%), using high surface area base material and

    special modification process. This unique ODS phase has high capacity and resolution, and is particularly

    effective not only precise separation of oils, fats and low polarity samples but also highly polar water soluble

    samples, which are difficult to discriminate with conventional ODS phase. It is suitable for isomeric separation of

    organic compounds and gradient elution of modified amino acids. Comparison of hydrophobic retention for other

    brand ODS phase is shown in Fig-1.

    Column size : 4.6mmx150mm.Mobile phase : MeOH/ Water =50/50 (v/v)Flow : 1.0 mL/min, Temp. : 40, Detection : UV 254 nm.Sample :1. Uracil, 2. Caffein, 3. Phenol, 4. Methylbenzoate,5. Benzene, 6. N, N-dimethyl aniline, 7. Toluene,8. Phenylacetylacetone

    !"#

    #"$

    %"&

    &"'

    ((")

    (*"&

    (+"*

    (+"&

    ($"+

    (&")

    !$"'

    '"' +"' ('"' (+"' *'"' *+"' !'"' !+"' #'"' #+"'

    ,-./01234($

    ,-./035234$

    67849:;234($

    45?=4;,;@AB;A:BC

    ,-./03D234($

    ,-./03E24($

    45?=4;,;@AB;A:B5

    ,-./03C24($

    45?=4;:;

  • URL ; http://www.chemco.jp/!E-mail : info@chemco.jp

    CHEMCOSORB 5-ODS-UH, the best material for scale up.

    The retentive property of CHEMCOSORB 5-ODS-UH gives advantage in preparative chromatography. As shownin Fig-2, extremely large capacity of CHEMCOSORB 5-ODS-UH enables to load more concentrated sample than

    other ODS columns, while maintaining good resolution under over load condition. In preparative

    chromatography, CHEMCOSORB 5-ODS-UH is the best alternative to reduce total production cost and achieve

    efficient separation.

    Mobile phase; 80% MeOH, Column Size ; 4.6 mm I.d. x 150 mm. Flow ; 1.0 mL/min,

    UV 300nm (over load injection) , Sample ; 1. Ethyl paraben, 2. Butyl paraben.

    Conventional ODS

    (350 m2/g, 14%C)

    1 g Injection

    (Injection vol. 1 L)

    "#$$ % # &'()*+,)(-.

    1

    2

    "#$$ % # &'()*+,)(-.

    25, mg Injection

    (Injection vol. 100 L)

    "#$$ % # & / 0'()*+,)(-.

    Chemcosorb 5ODS-UH

    (600 m2/g, 30%C)

    "#$$ % # & / 0'()*+,)(-.

    Fig-2. Comparison of peak shape under over load condition.

    U-13!Barbiturates

    CHEMCOSORB 5ODS-UH

    4.6!X150mm

    CH3OH/H2O(49:51)

    1.0mL/min, 4012 UV

    220nm

    1.Barbital 2.Allobarbital

    3.Aprobarbital

    4.Butabarbital 5.butarbital

    6.Hexobarbital

    7.Pentobarbital

    8.Secobarbital

    U-26! Nucleotides

    CHEMCOSORB 5C8-U

    4.6!X250mm

    0.1M NH4H2PO4(pH

    3.7/H3PO4)

    1.5mL/min, 4012 UV 254nm

    1.ATP 2.ADP 3.IMP 4.AMP

    5.Hypoxannthine 6.Inosine

    U-25!Fullerenes

    CHEMCOSORB 5ODS-UH

    4.6!X150mm

    C6H6CH3/CH3CN(60:40)

    1.5mL/min, ambient, UV @ 285nm

    1. Fullerene C60, 2. Fullerene C70

    U-19 34567849:;?:@

  • URL ; http://www.chemco.jp/!E-mail : info@chemco.jp

    CHEMCOBONDTMCHEMCOBOND series packings are prepared from ultra pure silica gel that is

    obtained by sol-gel technology. Due to its narrow particle size distribution,

    CHEMCOBOND series give lower column back pressure than CHEMCOSORB. Peakshape for basic and chelateing solute are improved because of excellent endcaping

    and metal free silica gel. ( Chemical phase; ODS, C8, NH2 and OH2 (diol), Particle

    diameter; 3.5 m, 5 m, Pore diameter; 10 nm )

    CHEMCOBOND ODS-W is specially designed ODS phase for polar solute separationin aqueous mobile phase. By optimizing silica pore size and ODS coverage, this

    phase allows to use highly aqueous mobile phase for separation of polar solutes with

    good retention reproducibility.

    0 5 10 15

    Tryptic digest of bovine serum albumin.

    CHEMCOBOND 5-ODS-W, 4.6!x150mm

    2.0 mL min, 0% A-60%B in 15 min.

    A: 0.1% TFA, B: 0.1% TFA in Acetonitrile

    CHEMCOBOND 3.5-ODS-H

    QUICKSORBOur new ODS phase, QUICKSORB (18 nm pore, 200 m2/g, 13% carbon), is

    suitable for high throughput HPLC separation. It reduces the actual analysis time in

    isocratic elution. In spite of shorter analysis time, the chromatographic performance

    is still maintained. In addition, the ultimate end capping and pure silica gel enableexcellent peak shape for basic and/ or chelating samples.

    Fig-1 shows the chromatogram of 8 test solutes including basic and chelating

    compounds. QUICKSORB separates these compounds with shorter and excellent

    peak shape.Quicksorb 3 um

    -H

    B-8!Nucleosides

    CHEMCOBOND 5ODS-H!4.6!X250mm

    (22.5mM KH2PO4+2.5mM Na2HPO4)

    [pH5.91]/CH3OH(91:9)

    1.0mL/min, 4012 UV 260nm

    1.Cytosine 2.Cytidine 3.Guanine 4.Uridine

    5.Thymine 6.Guanosine 7.Adenine 8.Thymidine

    9.Adenosine

    B-11!Antidepressant Drugs

    B-6!Anticonvalsants

  • URL ; http://www.chemco.jp/!E-mail : info@chemco.jp

    First LC Column

    Conventional Column

    I.D., 3.0, 4.0, 4,6, 6,0 mm

    Semi-Micro Column

    I.D., 1.0, ( 2.0 ), 2.1 mm

    Semi-Prep Column

    I.D., 7.5, 10.0 mm

    Prep ColumnI.D., 20.0, 30.0 mm

    HPLC COLUMNS

    Table1. HPLC phase specifications.

    Chemcopak HPLC Columns

    We can pack any size of column.

    (Diameter 1.0 mm - 30 mm, column length

    10 500mm.)

    In addition to conventional size column,

    micro capillary columns (diameter 0.1,

    0.32, 0.53mm) are available for specific

    application. These columns are sold by

    name of chemcopak e-series.

    HORIKAWA BLDG.,

    2-8-14,NAKAZAKI, KITA-KU, OSAKA, JAPAN

    Tel: +81-6-6375-0395!Fax: +81-6-6372-0533

    Particle Pore Surface Carbon Particle Pore Surface CarbonDiameter Size Area Content Diameter Size Area Contentm (nm) (m2/g) (%) m (nm) (m2/g) (%)

    QUICKSORB 3, 5 18 200 13 Si-U 5, 10 ----ODS-H 3.5, 5 10 340 22 C8-U 5, 10 14ODS-W 5 13 300 15 ODS-UH 5, 10 30C8 5 10 340 ---- Dph-U 5 ----NH2 3.5, 5 10 340 ---- CN-U 5 ----OH(Diol) 5 10 340 ---- NH2-U 5 ----Si 5, 7 8 ---- SCX 7 8 450 ----C8 7 8 9 SAX 7 8 450 ----ODS-L 5, 7, 10 10 10 300-CM 7 30 100 ----ODS-H 5, 7, 10 10 20 300-DEAE 7 30 100 ----Dph 5, 7 8 7 300-Si 7 100 ----TMS 5, 7 8 5 300-C4 7 100 0.8NH2 5, 7 8 ---- 300-C8 7 100 2.5CN 7 8 ---- 300-ODS-L 7 100 4120-Si ---- 300-C18 5, 7 30 100 6C8 8 300-Dph 7 100 1.2ODS-L 9 300-CN 7 100 ----ODS-H 18 300-NH2 7 100 ----Dph 6 300-OH 7 100 ----TMS 4 I-Si ----CN ---- I-C18 10NH2 ----

    250

    Column

    CHEMCOSORB

    6 600CHEMCOSORB

    12

    450

    200

    5, 7, 10 10

    CHEMCOSORB

    Column

    CHEMCOBOND

    3

  • Specialist

    URL ; http://www.chemco.jp/E-Mail ; info@chemco.jp

    mailto:info@chemco.jphttp://www.chemco.jphttp://www.chemco.jpmailto:info@chemco.jp

Recommended