10
DESCARGA BAJO UNA COMPUERTA LABORATORIO DE HIDRAULICA INGENIERIA CIVIL - UNISUCRE VI. SEMESTRE 2013- II

informe Descarga Bajo Una Compuerta

Embed Size (px)

DESCRIPTION

hidraulica

Citation preview

DESCARGA BAJO UNA COMPUERTA

DESCARGA BAJO UNA COMPUERTALABORATORIO DE HIDRAULICA

INGENIERIA CIVIL - UNISUCRE

VI. SEMESTRE2013- II

LABORATORIO DE HIDRAULICA

DERIVACION DE LA ECUACION DE ENERGA ESPECFICA

INTEGRANTES:JAIR ARRIETA BALDOVINOFRANK MANCILLA GONZALEZHEIDER MENDEZ MARTNEZJAVIER VITOLA MARTINEZ

VI SEMESTRE ING. CIVILJORNADA PLENA

DOCENTE:ING. LUIS DIAZ

UNIVERSIDAD DE SUCREFACULTAD DE INGENIERADEPARTAMENTO DE INGENIERA CIVILSINCELEJO, SUCRESEPTIEMBRE 2013RESULTADOS

Resultados obtenidos durante la prctica de laboratorio:COMPUERTA EN CANALES

Q (lts/min)h (mm)yo (mm )yi (mm)

Q131,95163,56, 8

31,97958,8

31,9967,210

31,91149,311,7

31,91436,313,7

Q24681878,7

4610111,610,6

461286, 312

461562,914,2

461847,116,3

Dnde:Q es el caudal en litros/ minutoh es la abertura de la compuerta en mmyo es la altura del tirante en el canal aguas arribayi es la altura del tirante en el canal aguas abajo

CALCULOSDatos bsicos para el clculo de las principales caractersticas del flujo en el canal:CAUDAL(M3/S)yo (m )yi (m)Ancho B canal (m)A yo (m2)A yi(m2)

0,0005316670,16350,00680,0750,01226250,00051

0,0005316670,0950,00880,0750,0071250,00066

0,0005316670,06720,010,0750,005040,00075

0,0005316670,04930,01170,0750,00369750,0008775

0,0005316670,03630,01370,0750,00272250,0010275

0,0007666670,1870,00870,0750,0140250,0006525

0,0007666670,11160,01060,0750,008370,000795

0,0007666670,08630,0120,0750,00647250,0009

0,0007666670,06290,01420,0750,00471750,001065

0,0007666670,04710,01630,0750,00353250,0012225

Se presentaran a continuacion tablas de los respectivos caudales con sus tirantes aguas arriba y aguas abajo mostrando las velocidades que se obtuvieron:CAUDAL(M3/S)yo (m )yi (m)Ve. yo(m/s)Ve. yi(m/s)

0,0005316670,16350,00680,0433571191,04248366

0,0005316670,0950,00880,0746198830,805555556

0,0005316670,06720,010,1054894180,708888889

0,0005316670,04930,01170,143790850,605887939

0,0005316670,03630,01370,1952861950,517437145

0,0007666670,1870,00870,054664291,174968072

0,0007666670,11160,01060,0915969730,964360587

0,0007666670,08630,0120,1184498520,851851852

0,0007666670,06290,01420,1625154570,719874804

0,0007666670,04710,01630,2170323190,627130198

Tabulacion de regmenes que presentan los flujos en cada una de las coniciones:CAUDAL(M3/S)yo (m )yi (m)Froude yo FroudeyiReinolds yoReinoldsyi

0,0005316670,16350,00680,034234744,0362708041481,0234016719,767576

0,0005316670,0950,00880,077296222,7416982662246,6845566429,496838

0,0005316670,06720,010,1299241122,2633080372843,2254416267,067445

0,0005316670,04930,01170,206763221,7884008723429,5587976050,522431

0,0005316670,03630,01370,3272530691,411441284033,6816215814,173899

0,0007666670,1870,00870,0403597444,0219061781912,0919879291,442662

0,0007666670,11160,01060,0875416092,9905565312879,0385718924,421018

0,0007666670,08630,0120,1287344022,4827840413467,4042898672,013151

0,0007666670,06290,01420,2068877831,9287604754275,5443338302,991315

0,0007666670,04710,01630,3192856891,5683009585074,0502487978,896859

Tomado una viscosidad promedio de: 0,000000893.A continuacin se presentan las alturas de carga para cada caudal y su respectiva abertura de compuerta la cual determina las aturas de tirantes aguas arriba y aguas abajo:CAUDAL(M3/S)yo (m )yi (m)Ho (m)Hi(m)Ho (mm)Hi(mm)

0,0005316670,16350,00680,1635958120,062191039163,595812462,19103882

0,0005316670,0950,00880,0952837990,04187440195,2837985241,87440128

0,0005316670,06720,010,0677671770,03561281667,7671772335,61281635

0,0005316670,04930,01170,0503538130,03041050950,3538128730,41050942

0,0005316670,03630,01370,0382437660,0273463438,2437664727,34634043

0,0007666670,1870,00870,1871523030,079064422187,15230379,06442248

0,0007666670,11160,01060,1120276250,05800017112,027625258,00017032

0,0007666670,08630,0120,0870151050,048985387,0151053748,98529957

0,0007666670,06290,01420,064246140,0406128364,2461403540,61283048

0,0007666670,04710,01630,0495007660,03634547849,5007659336,34547833

ANALIZAR LOS PATRONES DE FLUJO