LOCATED IN STBD NOSE COMPARTMENTPROVIDES 36V AC THREE PHASE, 400HZ
EQUIPMENT FAILURES DUE TO • FAN COVER DAMAGE• FAILURE OF BEARING• MALFUNCTIONING OF CENTRIFUGAL S/W• RESISTORS OUT OF ADJUSTMENT
FAILURE WILL CAUSE DE-ENERGISING OF 36V EMERGENCY BUS BAR
INPUT VOLTAGE – 27V DC±2.7VINPUT CURRENT – 14.0 AMPSOUTPUT VOLTAGE – 35.5 TO 40.0V ACTHREE PHASE, SINE WAVEAC LOAD CURRENT – 3.2 AMPSOUTPUT FREQUENCY – 400 HZ±2%OUTPUT POWER – 200VAEFFICIENCY – 31.7% MINIMUMPOWER FACTOR – 0.6 (INDUCTIVE)OPERATING TEMPERATURE - ±60°CALTITUDE FOR CONTINUOUS OPERATION UPTO 15,000 M - RATED LOAD
18000 M - 75% LOADWEIGHT – 08.6 KGADDITIONAL REQUIREMENTS – REMOTE ON/OFF AND OVERLOAD PROTECTION
TECCHNICAL
SPECIFICATIONS
EQUIPMENT ELECTRO-MECHANICAL AND ROTARY IN NATURE REQUIRED TO BE REPLACED WITH SOLID STATE STATIC VERSIONDESIGN CLEARANCE FROM CEMILAC
THE REQUIREMENT FOR FIVE YEARS IS 250